MINIMALLY INVASIVE PLATE OSTEOSYNTHESIS FOR DISTAL RADIUS FRACTURES: SURGICAL TECHNIQUE M. TOBE 1, K. MIZUTANI 1, Y. TSUBUKU 1, Y.

Similar documents
ORIGINAL ARTICLE TREATMENT DISTAL RADIUS FRACTURE WITH VOLAR BUTTRESS TECHNIQUE- A CLINICAL STUDY

LISS DF and LISS PLT. Less Invasive Stabilization Systems for Distal Femur and Proximal Lateral Tibia.

Technique Guide. 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

Mark VanDer Kaag 1, Ajmal Ikram 2. Hand Unit, Tygerberg Hospital University of Stellenbosch

INTERNAL FIXATION OF THE METACARPALS AND PHALANGES P. BURGE

The NBX Non-Bridging External Fixator A Non-Bridging External Fixator/Locking Plate capturing a series of.062mm K-wires and 3mm half-pins that are

CASE REPORT. Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report

Treatment of unstable distal radius fractures with the volar locking plate

Distal femoral fracture with subsequent ipsilateral proximal femoral fracture

Volar fixed-angle plating for distal radius fractures 刀圭会協立病院 津村敬

WINSTA-R. Distal Radius System

Complications of Distal Radius Fractures. How to Treat a Distal Radius Fx 11/13/2017. Michael S. Bednar, M.D. Loyola University Chicago

Angle Stable Distal Radial Plate System WINSTA-R

COMPARATIVE STUDY OF FUNCTIONAL OUTCOME OF EXTERNAL AND INTERNAL FIXATION IN TREATMENT OF COMMINUTED DISTAL RADIUS FRACTURES

Locked Plating: Clinical Indications

Orthopedics in Motion Tristan Hartzell, MD January 27, 2016

QUICK REFERENCE GUIDE. The Pennig Dynamic Wrist Fixator. Part A: Trans-articular application

Distal Radius Plate Instrument and Implant Set. Discontinued December 2017 DSUS/TRM/0916/1063(1)

2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

Disclosures. Distal Radius Fractures 5/16/2017. Distal Radius Fractures: Complications & Limitations of the Volar Approach

Surgical Care at the District Hospital. EMERGENCY & ESSENTIAL SURGICAL CARE

Instrument and Implant for wrist fracture

Index. Note: Page numbers of article titles are in boldface type. Hand Clin 21 (2005)

Distal Radius and Distal Ulna Plates System Self-Tapping Spherical Locking Screw Self-Tapping Conical Locking Screw Cortex Screw

Variable Angle LCP Volar Rim Distal Radius Plate 2.4. For fragment-specific fracture fixation with variable angle locking technology.

Chapter 4: Forearm 4.3 Forearm shaft fractures, transverse (12-D/4)

Techique. Results. Discussion. Materials & Methods. Vol. 2 - Year 1 - December 2005

Acu-Loc Wrist Plating System. Surgical Technique

6/5/2018. DISCLOSURES Hassan R. Mir, MD, MBA, FACS. Evolution of Distal Radius Fracture Treatment [Chung Hand Clinics 2012]

Emile N. Brown, MD, and Scott D. Lifchez, MD

JMSCR Vol 05 Issue 06 Page June 2017

Distal Radius Plate 2.4/2.7 dorsal and volar

Disclosure. 85% Dorsal. 15% Volar. Distal Radius Fractures- Volar Plating for All. Skeletal Dynamics- Consultant

Acu-Loc Wrist Spanning Plate System. Surgical Technique

MICRONAIL. Intramedullary Distal Radius System SURGICAL TECHNIQUE

Hand and wrist emergencies

Management of intra-articular fractures of distal end radius in adults

Wrist Fixation System

Fractures and dislocations around elbow in adult

Study of Evaluation of Lateral Surgical Approach for Diaphyseal Fractures of Distal 2/3rd of Radius at a Tertiary Care Teaching Centre

Acute Rupture of Flexor Tendons as a Complication of Distal Radius Fracture

Failed Extensor Indicis Proprius Tendon Transfer for Extensor Pollicis Longus Tendon Rupture after Distal Radial Fracture

AO / Synthes Proximal Posterior Medial Tibia Plate. Tibial Plateau Fx. Osteosynthesis

Long Volar Plates for Diaphyseal-Metaphyseal Radius Fractures LCP. Dia-Meta Volar Distal Radius Plates. Surgical Technique

Evaluation of volar locking plate fixation for management of intraarticular fractures of distal end of radius

BASIC PRINCIPLES OF HAND TRAUMA: ARE CHILDREN DIFFERENT? SUSAN THOMPSON, MD, FRCSC

NEW INSTRUMENTS FOR INTERNAL FIXATION OF FRACTURES USING MINIMALLY INVASIVE TECHNIQUES

Acomparison of percutaneous and pin-and-plaster techniques in distal radius fracture

University of Groningen. Fracture of the distal radius Oskam, Jacob

Index. Springer International Publishing Switzerland 2016 J.N. Lawton (ed.), Distal Radius Fractures, DOI /

Visualize, stabilize, mobilize. Wristore * Distal Radius Fracture Fixator Abbreviated Surgical Technique

Upper limb fractures. Mithun Nambiar Orthopaedic Resident Royal Melbourne Hospital

A N D R E W I R W I N, F R C S E D ( O R T H ) C O N S U L T A N T O R T H O P A E D I C S U R G E O N W E S T H E R T S N H S T R U S T, U K

Agee WristJack Multiplanar Ligamentotaxis

Malunited extra-articular distal radius fractures: corrective osteotomies using volar locking plate

Aesculap Orthopaedics Targon DR

ORIGINAL ARTICLE. possible. Accurate assessment of standard radiographs is essential for appropriate 3. management. And includes true posterior- 4

AcUMEDr. FoREARM ROD SYSTEM

Fractures of the Hand in Children Which are simple? And Which have pitfalls??

epak Single-Use Delivery System

BRIDGE PLATING OF COMMINUTED SHAFT OF FEMUR FRACTURES

LCP Proximal Radius Plates 2.4. Plates for radial head rim and for radial head neck address individual fracture patterns of the proximal radius.

Volar Distal Radius Plating System Surgical Technique

Comparative Study between Bridging External Fixation vs Volar Plating (Ellis-T Plate) for Comminuted Fracture of the Distal End Radius

Union Surgical. T-Pin. Fixation System for Distal Radius & Distal Ulna Fractures. Surgical Technique

E ORIGINAL ARTICLE Low extra-articular (transcondylar) fractures of the distal humerus

D-RAD SMART PACK Plating System. A series of case studies

Complications and functional outcome following fixation of complex, intra-articular fractures of the distal radius with the AO Pi-Plate

Surgical Technique Guide

Levels of the anatomical cuts of the upper extremity RADIUS AND ULNA right

Abd Ali Muhsin FICMS.

Volar Distal Radius Plating System Surgical Technique

Distal radius fractures raises considerable interest and

A Patient s Guide to Adult Distal Radius (Wrist) Fractures

ISSN (Online) ISSN (Print) Hospital, 7, Works Road, Chromepet, Chennai , Tamilnadu, India.

Locked Plating: Biomechanics and Biology

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

ROTATIONAL PILON FRACTURES

2.4 mm LCP Volar Column Distal Radius Plates. Part of the 2.4 mm LCP Distal Radius System.

Acu-Loc 2 Wrist Plating System

Conventus CAGE PH Surgical Techniques

Surgical Technique. Wrist Plating System

Factors Predicting Late Collapse of Distal Radius Fractures

The Flower Medial Column Fusion Plate

Primary internal fixation of fractures of both bones forearm by intramedullary nailing

LOCKING TEP LOCKING TITANIUM ELASTIC PIN INTRAMEDULLARY NAIL

University of Groningen. Fracture of the distal radius Oskam, Jacob

DVR Anatomic Plate. Surgical Technique

Forearm Fracture Solutions. Product Overview

Augmented external fixation of unstable distal radius fractures :

Non-comminuted extra-articular fractures of distal radius treated with Percutaneous pinning

A prospective study of surgical management of distal radius fracture in adult with plate fixation

A Patient s Guide to Adult Forearm Fractures

International Journal of Health Sciences and Research ISSN:

Radiographic Evaluation of Dorsal Screw Penetration After Volar Fixed-Angle Plating of the Distal Radius: A Cadaveric Study

University of Groningen. Fracture of the distal radius Oskam, Jacob

Types of Plates 1. New Dynamic Compression Plate: Diaphyseal fracture: Radius, Ulna, Humerus, Rarely tibia

Breakage of a volar locking plate after delayed union of a distal radius fracture

2.4 mm LCP Distal Radius System

A study of MIPO by locking compression plate fixation in the management of distal tibial metaphyseal fractures

Transcription:

Riv Chir Mano - Vol. 43 (3) 2006 MINIMALLY INVASIVE PLATE OSTEOSYNTHESIS FOR DISTAL RADIUS FRACTURES: SURGICAL TECHNIQUE M. TOBE 1, K. MIZUTANI 1, Y. TSUBUKU 1, Y. YANAGIHARA 2 1 Department of 2nd Orthopaedic Surgery, Toho University, Tokyo, Japan 2 Department of Orthopaedic Surgery, Sanno Hospital SUMMARY Purpose: Palmar locking plate has been undergone for dorsally displaced fractures of distal radius. But it is usually required with wide exposure involving the pronator quadratus muscle. A new technique of minimally invasive osteosysthesis using a new palmer locking plate system which are developed by authors is reported. Methods: From 2004 to 2006, 35 wrists in 35 patients with the mean age of 58 years. The type of fractures consist on 14 wrists in A2, 10 in A3, 7 in C1, 4 in C2 according to the AO classification. The follow-up period ranged from six to 24 months, with a mean of nine months. After incising the distal and proximal edges of the PQ, it is elevated subperiostcally. A locking plate is passed beneath the pronator quadratus muscle from the distal margin without transecting the muscle. Insertion of the proximal screws and reduction of the intra-articular fragment are performed through the limited incision of the pronator quadratus muscle. Active motion of fingers and wrist are started at next day after surgery. Results: Union was achieved in all fractures without loss of reduction in X ray measurement. The clinical evaluations were excellent in 33 wrists, good in 2 according to a modified the Green and O Brien score. An almost normal function was reached within 3 weeks follow-up examination. Conclusions: This new technique prevents soft tissue damage and adhesion around the pronator quadratus muscle. Although the indications of this technique are limited for the fractures of all extra-ariticular fractures or simple type of intra-articular fractures, we believe that distal radius fractures without severe comminution can be cured within three weeks. Riv Chir Mano 2006; 3: 280-284 KEY WORDS Osteosynthesis, distal radius, fractures INTRODUCTION Distal radius fractures are most common fracture in upper extremity. Many kinds of methods such as closed reduction with plaster immobilization, external fixator and conventional plate fixation from dorsal or palmar have been performed in the past. Recently, palmar locking plate has been used for dorsally displaced fractures of distal radius (1). But it is usually required with wide exposure involving the pronator quadratus muscle (PQ). Technique of minimally invasive plate osteosynthesis (MIPO) has been reported for the fractures in the lower extremity (2-4). They were developed to minimize soft tissue damage (5). In the up- Corrispondence: Takashi Sasaki, MD, Dept of Orthopaedic Surg Saiseikai-Kanagawaken Hospital, 6-6 Tomiyacho, Kanagawaku, Yokohama C. 2218601 Japan. Tel. +81-45-432-1111 - Fax +81-45-432-1119 - E-mail ssk_tks@ja2.so-net.ne.jp

MINIMALLY INVASIVE PLATE OSTEOSYSTHESIS FOR DISTAL RADIUS FRACTURES 281 per extremity, there is a report without transecting the pronator quadratus muscle for fractures of the metaphysis of the radius (6). A new technique of minimally invasive osteosysthesis using a palmar locking plate is reported. MATERIALS AND METHODS From 2004 to 2006, 35 wrists in 35 patients with the mean age of 58 years at the time of the injury (range, 24-88 years). The type of fractures consist on 14 wrists in A2, 10 in A3, 7 in C1, 4 in C2 according to the AO classification. The cause of injury was stumbling in 27, traffic accident in 6 and falling from a height in 2. The follow-up period ranged from six to 24 months, with a mean of nine months. All patients underwent to surgical treatment within 7 days; ranged from 2 to 7 days with a mean of 4 days. For the fixation, we have used distal window plate systems which were developed by authors. SURGICAL TECHNIQUE In all the patients surgery is performed with the patient in supine position under brachial plexus block or general anesthesia, and a pneumatic tourniquet is applied. Fluoroscopic examination is necessary to confirm the reduction. Henry approach, about 6 cm in length, is made. The fascia is divided longitudinally between the flexor carpi radialis tendon and the radial artery. After allowing retraction of flexor tendons and median nerve toward ulnar site, the entire pronator quadratus muscle is visualized. After incising the distal and proximal edges of the PQ, it is elevated subperiostcally (Fig. 1A). The fracture is reduced under fluoroscopic control. When good reduction is not achieved, Kapandji s technique is performed from dorsal site using a 1.8 mm K-wire. Dorsally displaced fragments of the distal radius usually exist in the distal portion of the pronator quadratus muscle, so a locking plate is passed beneath the muscle from the distal margin (Fig. 1B). It is important to note that the fracture is usually covered with the pronator quadratus muscle and it is easy to reduce the fracture without transecting through longitudinally. Correct placement of the plate over the fracture is confirmed by fluoroscopy. The plate is secured to the distal radius with distal locking screws which are inserted into subchondral bone just beneath the articular surface. The proximal site of the plate is lifted up using an elevator with an adapted angle under fluoroscopy (Fig. 1C). Subsequently, the proximal site of the plate is lined to the radial shaft. Since this procedure make the tension to the dorsal periosteum, the displaced fragments on the dorsal are reduced anatomically. We so called periost taxis. It is an important technique to achieve an exactly reduction. The alignment, radial length and rotation of the fracture were confirmed under fluoroscopy and screws are inserted in the proximal end of the plate. Transverse incision which is about 4 mm in a diameter is made in the muscle belly under fluoroscopy above the central screw hole. A central screw is inserted through the pronator quadratus muscle (Fig. 1D). When the reduction with bone grafting is required in comminuted fractures, it can be performed using the bone impactor through the window after transverse limited exposure on the PQ (Fig. 1E). After reduction for displaced fragments we usually use the injectable calcium phosphate bone cement (Fig. 1F). Thus, the reduction for the comminuted fractures is performed in minimally invasive technique (Fig. 1G, H). Active motion of fingers and wrist are started at next day after surgery. No splint and no external fixator are needed after surgery. The clinical assessment was assessed according to a modified the Green and O Brien score, the range of motion was measured on 1, 3, 6, 24 weeks and an X-ray measurement (palmar tilt and ulnar variance) was performed. RESULTS Union was achieved in all fractures. The clinical evaluations were excellent in 33 wrists, good in 2 according to a modified the Green and O Brien score.

282 M. TOBE, K. MIZUTANI, Y. TSUBUKU, Y. YANAGIHARA A B C D E F G H Figure 1. A) The pronator quadratus muscle is elevated by an elevator from distal radius; B) A plate is passed under the pronator quadratus muscle; C) The proximal site of the plate is lifted up using an elevator with adapted angle under fluoroscopy; D) After inserting the central screw. The plate is covered with the muscle; E) Transverse limited exposure is made to reduce the displaced intra-articular fragment using the bone impactor; F) Calcium phosphate bone cement is injected through the window; G) The X-ray before surgery. The central depression fracture is seen; H) The X-ray after surgery. Anatomical reduction is achieved. Early functional results are presented in figure 2. An almost normal function was reached within 3 weeks follow-up examination (Fig. 3). In X-ray measurement, there is no significant difference between just after surgery and 6 months after surgery in palmar tilt and ulnar variance (Fig. 4). DISCUSSIONS Several dorsal plates for dorsally displaced fracture of the distal radius have been developed based on the theory buttress effect. But many investigators have pointed out the complications of dorsal Figura 2. Early functional results in range of motion.

MINIMALLY INVASIVE PLATE OSTEOSYSTHESIS FOR DISTAL RADIUS FRACTURES 283 Figura 3. The graph in the term of return to daily activities. plating including tendon ruptures and irritations. And, dorsal plating using conventional plates cannot prevent radial shorting or displacement of the distal radius. In addition, a loosening of the screw and bone collapse may frequently occur in the elderly due to its osteoporosis. Palmar locking plate for dorsally displaced fracture of the distal radius has been reported recently. Distal fixation through the insertion of buttress pins just into the subchondral bone with an adjusted angle to the articular surface and the proximal limb of the plate lined up the radius shaft reduce the fracture anatomically in terms of radial length and palmar tilt. (1, 7-9) However, it is usually required wide exposure involving an injury to the pronator quadratus muscle. The PQ has two distinct heads. The superficial head is prime mover in forearm pronation and the deep head is a dynamic stabilizer of distal radio-ulnar joint (10). The pronator quadratus muscle is expanded about 1 cm by maximum pronation and supination (11). When the pronator quadratus muscle is divided longitudinally, adhesion around the muscle may inevitably occur. Therefore, an early exercise of forearm pronation and supination is limited in conventional palmar plating. This new technique prevents soft tissue damage and adhesion around the PQ. Keeping the PQ does not became a trouble during surgery and it yield to high functional results just after surgery. Although the indications of this technique are limited for the fractures of all extra-ariticular fractures or simple type of intra-articular fractures, we believe that distal radius fractures without severe comminution can be cured within three weeks. REFERENCE Figura 4. The outcomes of X-ray measurement in palmar tilt and ulnar variance. 1. Kiyoshige Y. Condylar Stabilizing Technique with AO/ASIF Distal Radius Plate for Colles Fracture Associated with Osteoporosis. Techniques in Hand & Upper Extremity Surgery 2002; 6: 205-8. 2. Krettek C, Schandelmaier P, Tscherne H. Distal femoral fractures. Transarticular reconstruction, percutaneous plate osteosynthesis and retrograde nailing. Unfallchirurg 1996; 99: 2-10. 3. Stoffel K, Klaue K, Perren SM. Functional load of plates in fracture fixation in vivo and its correlate in bone healing. Injury 2000; 31 (Suppl 2): 37-50. 4. Kregor PJ, Hughes JL, Cole PA. Fixation of distal femoral fractures above total knee arthroplasty utilizing the Less Invasive Stabilization System (L.I.S.S.). Injury 2001; 32 (Suppl 3): 64-75. 5. Farouk O, Krettek C, Miclau T, Schandelmaier P, Guy P, Tscherne H. Minimally invasive plate osteosynthesis: does percutaneous plating disrupt femoral blood supply less than the traditional technique? J Orthop Trauma. 1999; 13: 401-6. 6. Inamani L, Nada T, Morito Y, Sato T, Hashizume H, Inoue H. Minimally invasive plate osteosynthesis for comminuted fractures of the metaphysis of the radius. J Hand Surg 2005; 30B: 220-5.

284 M. TOBE, K. MIZUTANI, Y. TSUBUKU, Y. YANAGIHARA 7. Jupiter JB, Ring D, Weitzel PP. Surgical treatment of redisplacement fracture of the distal radius fracture in patients older than 60 years. J Hand Surg 2002; 27A: 714-23. 8. Orbay JL, Felnandez DL. Volar fixation for dorsally displacement fractures of the distal radius fracture: a preliminary report. J Hand Surg 2002; 27A: 205-15. 9. Gessensway D, Putnam MP, Mente PL, Lewis JL. Design and biomechanics of a plate for the distal radius. J Hand Surg 1995; 20A: 1021-7. 10. Stuart PR. Pronator quadratus revisited: J Hand Surg 1996; 21B: 714-22. 11. Haugstvedt JR, Berger RA, Berglund LJ. A mechanical study of the moment-forces of the supinators and pronators of the forearm. Acta Orthop Scand 2001; 72: 629-34.