T. GIRARD ( 1 ), C. KERN ( 2 ), I. HÖSLI ( 3 ), A. Heck ( 4 ) and M. C. SCHNEIDER ( 1 )

Similar documents
Mitra et al. Sri Lankan Journal of Anaesthesiology: 23(2):61-65(2015) DOI: /slja.v23i2.8068

Int J Clin Exp Med 2018;11(8): /ISSN: /IJCEM

Epidural Analgesia with Amide Local Anesthetics, Bupivacaine, and Ropivacaine in Combination with Fentanyl for Labor Pain Relief: A Meta-Analysis

PAIN AND REGIONAL ANESTHESIA

Comparison of ropivacaine 0.1%-fentanyl and bupivacaine 0.125% - fentanyl infusions for epidural labour analgesia

Y. Lim, 1 A. T. Sia 2 and C. E. Ocampo 3

OBSTETRICS Intrathecal morphine reduces breakthrough pain during labour epidural analgesia

Current Management of Labour Analgesia Epidural or CSE, Bolus or Infusions?

Combined spinalepidural. epidural analgesia in labour (review) By Neda Taghizadeh

Original article Pravara Med Rev 2010; 2(3)

CSE for labour analgesia. Roshan Fernando: University College Hospital, London

Although epidural bupivacaine is highly effective

Extradural pain relief in labour: bupivacaine sparing by extradural fentanyl is dose dependent

Epidural Analgesia: The Best Mix

LOW CONCENTRATION LIDOCAINE (0.5%) BOLUS EPIDURALLY CAN INITIATE FAST-ONSET, EFFECTIVE AND SAFE ANALGESIA FOR EARLY STAGE LABOR

Addition of Adrenaline to Chloroprocaine Provides a Moderate Duration Time for Epidural Anaesthesia in Elective Caesarean Section

Labor Epidural: Local Anesthetics and Beyond

Original Article Single-Shot Epidural Anaesthesia Pak Armed Forces Med J 2015; 65(5):

Closed-loop Double-pump Automated System Manual Boluses

Comparison of 0.125% ropivacaine-dexmedetomidine versus 0.125% levobupivacaine-dexmedetomidine for epidural labour analgesia

NEW MODES OF OBSTETRIC ANALGESIA: DOES PIEB MODE BRING A REAL BENEFIT?

How to reduce failure rate of regional anaesthesia for caesarean section? Mike Kinsella St Michael s Hospital, Bristol 4 th November 2010

COMPARATIVE ANAESTHETIC PROPERTIES OF VARIOUS LOCAL ANAESTHETIC AGENTS IN EXTRADURAL BLOCK FOR LABOUR

Although intrathecal (IT) sufentanil provides effective

The right drug and dose for neuraxial labour analgesia

Assistant Professor, Anaesthesia Department, Govt. General Hospital / Guntur Medical College, Guntur, Andhra Pradesh, India.

Patient-controlled epidural analgesia for labor

section: levobupivacaine 0.15% versus ropivacaine 0.15% alone or combined with fentanyl 2 µg/ml: a comparative study

COMPARISON OF THE EFFECT OF TWO DIFFERENT DOSES OF 0.75% GLUCOSE-FREE ROPIVACAINE FOR SPINAL ANESTHESIA FOR LOWER LIMB AND LOWER ABDOMINAL SURGERY

ORIGINAL ARTICLE. Srivastava Meghana 1, Arora Garima 2, Santpur Madhavi 3, Kanwal Preet 4, Bansal Karishma 4 ABSTRACT

Original Article Comparison of prophylactic bolus norepinephrine and phenylephrine on hypotension during spinal anesthesia for cesarean section

OBSTETRICS Effects of intrathecal and i.v. small-dose sufentanil on the median effective dose of intrathecal bupivacaine for Caesarean section

Combined Spinal epidural with Levobupivacaine or Ropivacaine with Fentanyl for Labor Analgesia: A Comparative Study

CHA Gumi Medical Center, CHA University, Gumi, Korea

Swiss Association of Obstetric Anesthesia Swiss Association of Anesthesia & Resuscitation Satellite Meeting Interlaken, Switzerland 2007 Lawrence C.

E. Sitsen (*), F. van Poorten (**), G. Jansen (***), R. Kuijpers (**), A. Dahan (*) and

Evaluation of the Effect of Magnesium Sulphate as Adjunct to Epidural Bupivacaine: An Institutional Based Study

Comparison Of Intrathecal Hyperbaric Ropivacaine And Bupivacaine For Caesarean Delivery

Efficacy Of Ropivacaine - Fentanyl In Comparison To Bupivacaine - Fentanyl In Epidural Anaesthesia

A clinical study of the effectiveness of continuous epidural labour analgesia for vaginal delivery with % bupivacaine with 0.

JMSCR Vol 07 Issue 02 Page February 2019

REVISTA BRASILEIRA DE ANESTESIOLOGIA

Spinal anesthesia : Comparison of plain ropivacaine, bupivacaine and levobupivacaine for lower abdominal surgery

Impact of Drug Delivery Systems on Neuraxial Labor Analgesia

Initiating Labour Analgesia in 2020: Predicting the Future Epidurals, CSEs, Spinal Catheters, Epidrum & Epiphany

Cesarean Section Should be Managed: Low Dose / CSE versus High Dose Spinals with Vasopressors

Effects of IV Ondansetron during spinal anaesthesia with Ropivacaine and Fentanyl

Epidural analgesia and backache: a randomized controlled comparison with intramuscular meperidine for analgesia during labour

Original Article Hyperbaric spinal anesthesia with ropivacaine coadministered with sufentanil for cesarean delivery: a dose-response study

OBSTETRICS Effect of i.v. phenylephrine or ephedrine on the ED50 of intrathecal bupivacaine with fentanyl for Caesarean section

Intermittent Epidural Bolus Compared with Continuous Epidural Infusions for Labor Analgesia: A Systematic Review and Meta-Analysis

Regional Anaesthesia for Caesarean Section

Comparative Study of Intrathecal Ropivacaine and Levobupivacaine With Fentanyl And Magnesium As Adjuvants For Lower Abdominal Surgeries

Induction position for spinal anaesthesia: Sitting versus lateral position

OB Div News March 2009

CSE Analgesia Represents the Gold Standard for Regional Analgesia in Labour

THE earliest reports of neuraxial analgesia for labor

Intrathecal 0.75% Isobaric Ropivacaine Versus 0.5% Heavy Bupivacaine for Elective Cesarean Delivery: A Randomized Controlled Trial

ED 50 of Hyperbaric Bupivacaine With Fentanyl for Cesarean Delivery Under Combined Spinal Epidural in Normotensive and Preeclamptic Patients

COMPARISON OF % BUPIVACAINE WITH % FENTANYL V/S % BUPIVACAINE IN AMBULATORY LABOR EPIDURAL ANALGESIA

Combined spinal-epidural versus epidural analgesia in labour (Review)

Sparing Effects of Sufentanil on Epidural Ropivacaine in Elderly Patients Undergoing Transurethral Resection of Prostate Surgery

WITH ISOBARIC BUPIVACAINE (5 MG/ML)

Intermittent Thoracic Epidural Administration of Ropivacaine-Fentanyl versus Bupivacaine-Fentanyl after Thoracotomy

Continuous Epidural Analgesia in Labour Using % Bupivacaine with % Fentanyl and 0.125% Bupivacaine Alone: A Randomized Study

A 5-Year Audit of Accidental Dural Punctures, Postdural Puncture Headaches, and Failed Regional Anesthetics at a Tertiary-Care Medical Center

The Labour Epidural: Troubleshooting

A comparative study of Ropivacaine and Bupivacaine in combined spinal epidural anaesthesia and Post- operative analgesia

COMPARISON OF INCREMENTAL SPINAL ANAESTHESIA USING A 32-GAUGE CATHETER WITH EXTRADURAL ANAESTHESIA FOR ELECTIVE CAESAREAN SECTION

International Journal of Health Sciences and Research ISSN:

Remifentanil in labour analgesia where are we in 2017 an update.

Introduction of a New Concept of Pain Management during Labor and a Novel Technique for Pain Free Labor

Guidelines for the Conduct of Epidural Analgesia for Parturients

Comparison of ropivacaine and bupivacaine in extradural analgesia for the relief of pain in labour

Maternal & fetal outcomes after regional labour analgesia Ultra low dose epidurals to BUMPES. Dr Bernard J Norman November 2012

Comparison of intrathecal isobaric bupivacaine±morphine and ropivacaine±morphine for Caesarean delivery ²

Comparison of 0.25% S( )-bupivacaine with 0.25% RS-bupivacaine for epidural analgesia in labour

Safety and quality of neuraxial analgesia. Ulla Sipiläinen HUCS Jorvi hospital

Efficacy of postoperative epidural analgesia Block B M, Liu S S, Rowlingson A J, Cowan A R, Cowan J A, Wu C L

CAESAREAN SECTION Brian Fredman

A comparison of epidural ropivacaine 0.75% and bupivacaine 0.5% with fentanyl for elective caesarean section

* id of corresponding author- Received: 12/12/2016 Revised: 15/02/2017 Accepted: 21/02/2017 ABSTRACT

DURAL PUNCTURE EPIDURAL ANALGESIA IS NOT SUPERIOR TO CONTINUOUS LABOR EPIDURAL ANALGESIA

Low dose levobupivacaıne 0.5% with fentanyl in spinal anaesthesia for transurethral resection of prostate surgery

Intrathecal Ropivacaine and Clonidine for Ambulatory Knee Arthroscopy

Original Article. MA Qadeer Khan 1, B Syamasundara Rao 2, SA Aasim 3 INTRODUCTION MATERIALS AND METHODS

Comparison between Patient-Controlled Epidural Analgesia and Continuous Epidural Infusion for Pain Relief after Gynaecological Surgery

Labor pain relief using bupivacaine and sufentanil: Patient controlled epidural analgesia versus intermittent injections

la Prilocaine Hyperbare Pourquoi Quand Comment

Intrathecal clonidine prolongs labour analgesia but worsens fetal outcome: a pilot study

Epidural Volume Extension In Combined Spinal Epidural Anaesthesia For Rapid Motor Recovery After Elective Caesarean SectionA Comparative Study

Mr David A McDonald Service Improvement Manager Whole System patient Flow Improvement Programme Scottish Government

prilocaine hydrochloride 2% hyperbaric solution for injection (Prilotekal ) SMC No. (665/10) Goldshield Group

ORIGINAL ARTICLE A COMPARATIVE STUDY BETWEEN 0.5% HYPERBARIC BUPIVACAINE AND 0.5% HYPERBARIC BUPIVACAINE WITH

Almost two decades have passed since French and American trials

David Gambling, MB, BS,* Jonathan Berkowitz, PhD, Thomas R. Farrell, MD, Alex Pue, MD,* and Dennis Shay, MD*

Patient-controlled analgesia: epidural fentanyl and i.v. morphine compared after Caesarean section

British Journal of Anaesthesia 97 (3): (2006) doi: /bja/ael182 Advance Access publication July 21, 2006

DORIS DUKE MEDICAL STUDENTS JOURNAL Volume V,

Comparasion of low dose bupivacaine and ropivacaine in low thoracic combined spinal epidural anaesthesia for laparoscopic cholecystectomy

Transcription:

(Acta Anaesth. Belg., 2006, 57, 45-49) Ropivacaine versus Bupivacaine 0.125% with Fentanyl 1µg/ml for Epidural Labour Analgesia : Is Daily Practice More Important Than Pharmaceutical Choice? T. GIRARD ( 1 ), C. KERN ( 2 ), I. HÖSLI ( 3 ), A. Heck ( 4 ) and M. C. SCHNEIDER ( 1 ) Summary : Ropivacaine might be superior to bupivcaine for epidural labour analgesia because it appears to induce less lower extremity motor blockade. The clinical relevance of this difference is not yet clear. Methods : In a double-blind randomised trial bupivacaine and ropivacaine each at 0.125% with 1 µg/ml fentanyl were compared for epidural labour analgesia. This study was performed in two university hospitals. Results : Sixty-three nulliparous women with singleton pregnancies at term were included. There were no differences between bupivacaine and ropivacaine as far as motor blockade, analgesic outcome, mode of delivery and neonatal outcome are concerned. However, the clinical management of epidural analgesia differed significantly between the two institutions involved. Parturients of one institution had their epidural catheter placed earlier, needed less top-up medication, and had more successful mobilisations, when compared to the other institution. Conclusions : Institutional clinical practice can be significantly different. Pharmacological differences between bupivacaine and ropivacaine at 0.125% with 1µg/ml fentanyl seem to be less important than differences between institutions in terms of clinical practice. Key words : Analgesia ; Epidural ; Bupivacaine ; Ropivacaine ; Parturition. Bupivacaine provides excellent analgesia for labour and delivery and remains the most widely used epidural local anaesthetic in obstetric anaesthesia (14). Ropivacaine, an amino-amide local anaesthetic that is structurally similar to bupivacaine, has a lower potential for cardiovascular and central nervous system toxicity. In addition, ropivacaine might be superior to bupivacaine because it appears to induce less lower extremity motor blockade, although the clinical value of this difference is unclear (9). A meta-analysis of studies comparing higher concentrations of ropivacaine and bupivacaine (0.25%-0.5%) suggested that the use of ropivacaine was associated with less instrumental deliveries and less motor blockade than bupivacaine (16). A more recent meta-analysis in 2074 patients (10) and a multi-centre study of the same group (9) were not able to confirm a difference in obstetric outcome. We performed a double-blind, randomised, multicentre comparison of bupivacaine and ropivacaine each at our routine clinical concentration of 0.125% with 1µg ml -1 fentanyl. The primary outcome measure of this study was the incidence of motor blockade. METHODS Local Research Ethics Committees approved this prospective, randomized and double blind study. Inclusion criteria were : written informed consent, ASA status I or II, nulliparity, singleton pregnancy, vertex presentation and cervical dilatation of 6 cm. Exclusion criteria were : absence of informed consent, contraindications for epidural anaesthesia, allergy to amide local anaesthetics, multi-parity, multi-foetal gestations, pre-term pregnancy (< 38 th week of gestation) and cervical dilation of > 6 cm at the time of epidural catheter placement. Randomisation was performed by the pharmacy of the Basel University Hospital where identical solutions of either ropivacaine or bupivacaine were prepared at a 0.125% concentration and identified by incremental numbers. A 20 ml syringe of the same drug at a concentration of 0.25% was labelled Girard T. 1, Kern C. 2, Hösli I. 3, Heck A. 4 and Schneider M.C. 1. (1) Department of Anaesthesia, University Hospital, Kantonsspital Basel, CH-4031 Basel, Switzerland ; (2) Department of Anaesthesia, University Hospital, Geneva, CH-1205 Geneva, Switzerland ; (3) Department of Obstetrics and Gynecology, University Women s Hospital, Kantonsspital Basel, CH-4031 Basel, Switzerland ; (4) Clinical Pharmacology, University Hospital, CH-8000 Zürich, Switzerland. Correspondence address : Dr. Thierry Girard, Department of Anaesthesia, University hospitals Kantonsspital, Basel CH-4031 Basel, Switzerland. Tel : +41 61 265 25 25. Fax : +41 61 265 73 20. E-mail: thierry.girard@unibas.ch

46 T. GIRARD et al. with the same number and available in case of insufficient analgesia (see below). The randomisation code was not revealed until completion of the study and digital data acquisition. Fentanyl was added to the epidural infusion to reach a final concentration of 1µg ml -1 (0.0001%) immediately before placement of the epidural catheter. After written informed consent, the parturient was positioned in a left lateral position. The epidural space was identified at L3/4 or L2/3 with an 18- gauge Tuohy needle using the loss of resistance technique to 0.9% saline. A 20-gauge single orifice epidural catheter (Perifix, B. Braun, Melsungen, Germany) was inserted 2-3 cm into the epidural space. After a negative test dose of 60 mg plain lidocaine 2%, the study solution was injected in increments of 5 ml every 3-10 min up to a maximum of 20 ml with adequate analgesia (visual analogue scale [VAS] of 3) as an endpoint. On the basis of initial dose requirements the hourly epidural infusion rate was set between 8 and 12 ml h -1. Initial dose and time required to reach a VAS 3 were noted. Vital parameters, VAS score, motor block (modified Bromage scale (3), i.e. 0 : normal movement in hip, knee and foot ; 1 : weakness in hip muscle ; 2 : weakness of the knee muscles ; 3 : motor block of hip, knee and foot and sensory level of anaesthesia were recorded after 15, 30 and 60 min and then every 60 min. Inadequate analgesia was defined as VAS >3 and treated with incremental interventions : a 5 ml bolus of the study solution, epidural application of 1µg kg -1 fentanyl (maximal 100 µg) and a 5 ml bolus of a 0.25% study solution. If insufficient analgesia persisted, the patient was excluded from the study and the catheter had to be resited. Statistical analysis With an estimated incidence of motor block (Bromage >1) of 30-40% in the bupivacaine group, Table 1 Characteristics of parturients receiving either bupivacaine or ropivacaine for epidural labour analgesia. Values are number (proportion) or mean (SD). Studied in Basel 11 (52%) 10 (48%) Studied in Geneva 22 (56%) 17 (44%) Age ; years 29.3 (5.2) 28.7 (5.5) BMI ; kg/m 2 27.9 (3.5) 28.4 (4.3) Gestation age ; weeks 39.5 (1.1) 39.6 (1.5) Duration of epidural analgesia ; min 374.5 (159.8) 392.8 (150.5) Application of oxytocin 12 (36%) 8 (30%) Cervical dilation < 4 cm 26 (79%) 18 (66%) BMI = Body mass index we expected a reduction in motor block of about 50% in the ropivacaine group. To achieve a power of 0.8 we needed 34 parturients in each group. Values presented are mean and standard deviation. Nominal data were compared using the Chi-square test and Fisher s exact test where appropriate. Continuous parameters were compared with student s t-test for unpaired samples, pain scores and motor block were compared using Mann-Whitney U-tests. Significance levels were set to 5%. RESULTS Sixty-three parturients were included in the study, 30 in the ropivacaine and 33 in the bupivacaine group. Three parturients of the ropivacaine group were excluded from further analyses, one due to technical problems with the epidural analgesia, and two because they did not meet the inclusion criteria : one parturient had a twin pregnancy, the other one was multipara. There were no significant differences in demographic data (Table 1). Table 2 shows that 15 parturients (45%) in the bupivacaine group and 17 (63%) in the ropivacaine group did not show any motor block (Bromage = 0) throughout labour ; there were no differences in motor block between the two drugs (Chi-Square = 1.84, p = 0.4). As parturients with epidural analgesia were not commonly mobilized at the time the study was performed, mobilisation was not attempted in 32 parturients (53%). In 5 patients mobilisation was not possible (3 in the bupivacaine, 2 in the ropivacaine group), motor block being the reason in 4 of the 5. Table 2 Maximal motor block Bupivacaine Ropivacaine n = 33 n = 27 Bromage 0 15 (45%) 17 (63%) Bromage 1 13 (39%) 7 (26%) Bromage 2 5 (15%) 3 (11%) Bromage 3 0 0 Table 3 Obstetrical outcomes for parturients receiving either bupivacaine or ropivacaine for epidural labour analgesia. Values are number (proportion). n = 33 n = 27 Spontaneus vaginal delivery 11 (33%) 13 (48%) Instrumental vaginal delivery 15 (45%) 11 (41%) Caesarean section 7 (21%) 3 (11%)

ROPIVACAINE VS. BUPIVACAINE FOR LABOUR ANALGESIA 47 Table 6 Differences in clinical management of epidural labour analgesia between the Basel and Geneva centres. Values are numbers (proportions). Basel Geneva p-value n = 21 n = 39 Cervical dilation < 4 cm 48% (26-70) 87% (71-95) 0.0009 Successful mobilisation 1 (5%) 22 (56%) 0.00003 Fentanyl top up 11 (52%) 6 (15%) 0.006 0.125% top up 14 (67%) 28 (72%) 0.68 0.25% top up 8 (38%) 3 58%) 0.004 Fig. 1. Pain scores measured as visual analogue scale in parturients receiving epidural analgesia with bupivacaine (hatched boxes) or ropivacaine (open boxes) 0.125% with 1µg ml -1 fentanyl. Scores before initiation of epidural analgesia (pre) were significantly higher, than those after insertion of the epidural catheter (15 min.) and 30, 60 or 120 minutes later. The data is shown as boxplots indicating median, 10 th,25 th, 75t h and 90 th percentiles. There were no significant differences between the two drugs at any time point, p-values are Mann-Whitney U- tests without correction for multiple comparisons. Table 4 Neonatal outcomes for parturients receiving either bupivacaine or ropivacaine for epidural labour analgesia. Values are number, median [range] or mean (SD). Apgar at 1 min 9 [7-10] 9 [6-10] Apgar at 5 min 10 [8-10] 10 [7-10] Umbilical arterial ph 7.21 (0.065) 7.20 (0.065) Obstetrical outcomes were comparable, as shown in Table 3, and there were no differences in neonatal outcome as far as Apgar scores at 1 and 5 minutes and umbilical arterial ph were concerned (Table 4). Analgesia was comparable between the ropivacaine and bupivacaine groups, as indicated by comparable frequencies in top-up requirements (Table 5) and lack of significant differences in VAS scores (Fig. 1). Surprisingly, our post-hoc analysis suggested significant difference between the two institutions Table 5 Initial local anaesthetic volume and frequency of topup medication with 0.125% and 0.25% local anaesthetics and fentanyl. Values are median (range) or number (proportion). (n = 33) (n = 27) Initial volume of local anaesthetic ; ml 10 (5-20) 10 (3-20) 0.125% top up 22 (66%) 20 (74%) 0.25% top up 5 (15%) 6 (22%) Fentanyl top up 9 (27%) 8 (30%) involved in this study. While the distribution of ropivacaine and bupivacaine was homogenous between Basel and Geneva (p = 0.79, Table 1), parturients in Geneva had their epidural catheter placed earlier, needed less top-up medication and had more successful mobilisations (Table 6). DISCUSSION We did not find any difference in the incidence of motor block between parturients receiving either ropivacaine or bupivacaine each at 0.125% with 1µg ml -1 fentanyl for epidural labour analgesia. Moreover, there were no differences in analgesic, obstetrical or neonatal outcomes. This study was designed to detect a 50% reduction in motor block incidence during labour epidural analgesia, because such a reduction was thought to be clinically relevant. Indeed, there were more parturients without motor block in the ropivacaine group than in the bupivacaine group (45 vs. 63%). However, this difference was neither statistically significant nor clinically relevant. We note that our study did not have enough power to exclude such a difference. In a larger mulitcentre, randomised, controlled study comparing dilute concentrations of ropivacaine and bupivacaine (initiation of analgesia with a 15 ml bolus of 0.1% local anaesthetic with fentanyl 5µgml -1, followed by patient controlled epidural analgesia with either local anaesthetic at a concentration of 0.08%, with fentanyl, 2 µg ml -1 ), there was a statistically lower incidence of motor block in the ropivacaine group at 6 h and 10 h after drug injection(9). Several studies have compared bupivacaine and ropivacaine for labour analgesia. They were recently summarised in a meta-analysis by Halpern et al. (10). In 19 of 23 studies analysed, motor block was more frequent in the bupivacaine group than in the ropivacaine group. However, motor block was not included in their meta-analysis because data

48 T. GIRARD et al. were heterogeneous. Nevertheless, these results are consistent with the trend towards less motor block with ropivacaine, also observed in our study. Many studies have compared equal concentrations of bupivacaine and ropivacaine, although a randomised study design based on sequential up-down allocation of parturients suggested the 50 % effective dose (ED50) of ropivacaine to be 40 % higher than that of bupivacaine (1,4,11,15). However, the ED50 may be a poor predictor for clinically relevant outcomes in labour analgesia (13), as indicated by several studies which did not reveal any difference in the amount of local anaesthetics required by parturient controlled epidural analgesia when identical concentrations of bupivacaine and ropivacaine were used (2,4,6,8,9,15). In contrast to a meta-analysis performed by Writer et al., which suggested that the use of ropivacaine for labour analgesia was associated with more spontaneous vaginal deliveries than the use of bupivacaine (16), a more recent meta-analysis did not confirm these results (10). The latter included 23 randomised controlled trials composed of 1043 individuals receiving ropivacaine and 1031 receiving bupivacaine for labour analgesia. The incidence of spontaneous vaginal delivery as primary outcome was not different (odds ratio, 1.17, 95% confidence interval 0.98-1.41, p = 0.12) between both groups (10). In accordance with these results and other studies, we also did not detect any differences concerning mode of delivery nor neonatal outcome (2,9,12). Despite the small sample size, we found significantly different outcomes between the two involved institutions. The proportion of parturients receiving epidural analgesia during early labour (cervical dilatation < 4 cm) was almost twice as high in Geneva as in Basel and was associated with a significant reduction in subsequent top-up doses of 0.25% local anaesthetics or supplemental epidural fentanyl. In addition, the proportion of women successfully mobilized was significantly higher in Geneva than in Basel. These results have to be interpreted with some caution, as differences between the two centres were not defined as outcome variables and are part of the post-hoc analysis. On the other hand rigorous inclusion and exclusion criteria were defined in order to achieve comparable results and reduce the impact of confounding factors. Moreover, all drugs were prepared in one centre (Basel) and this centre also supplied epidural puncture sets with Tuohy needles and epidural catheters. Geneva is the largest obstetrical unit in Switzerland with about 3800 deliveries per year and an epidural rate exceeding 80%. Basel, on the other hand, has only about 1600 deliveries per year with and a markedly lower epidural rate of about 40%. Therefore experience with epidural analgesia might be greater in Geneva than in Basel. We cannot exclude the possibility that differences in patient characteristics and attitudes towards birth experience may have contributed as confounding factors to differences in the management of epidural analgesia found in these two institutions. Obviously, a twofold lower proportion of parturients delivering without epidural analgesia in Basel than in Geneva might lead to a selection bias in Basel in favour of patients presenting with pathological or extremely painful pregnancies. Interestingly, differences in cervical dilation at the time of initiation of epidural analgesia observed in both institutions had no influence on subsequent analgesic requirements. Therefore, despite some observations to the contrary (5), the impact of cervical dilatation as a possible confounding variable was minimal or absent from our trial. It is of interest to note the large difference in the proportion of spontaneous vaginal delivery reported by studies of epidural labour analgesia. Halpern et al. found 45-50% spontaneous vaginal delivery, which is in agreement with European and Chinese studies (8,9,12), while investigators from Israel and Turkey report values as high as 80-90% and 100%, respectively (2,7). Many studies have demonstrated comparable analgesia with bupivacaine and ropivacaine for labour analgesia and most would agree with Polley et al. that any difference between these drugs is unlikely to have a substantial clinical relevance (14). Differences between institutional policies and experiences, regional and national cultural differences might be far more important, than minor differences in pharmacological properties of ropivacaine versus bupivacaine, at least when dilute concentrations of local anaesthetics combined with lipophilic opioids are used. Acknowledgments We thank Mrs Joan Etlinger, BA for expert editorial assistance. We also thank Astra-Zeneca for supplying the ropivacaine used in this study. References 1. Alahuhta, S., Ala-Kokko, T. I., Ropivacaine : a new agent for epidural labour analgesia? ACTA ANAESTHESIOL SCAND, 42, 887-889, 1998.

ROPIVACAINE VS. BUPIVACAINE FOR LABOUR ANALGESIA 49 2. Bolukbasi, D., Sener, E. B., Sarihasan, B., Kocamanoglu, S., Tur, A., Comparison of maternal and neonatal outcomes with epidural bupivacaine plus fentanyl and ropivacaine plus fentanyl for labor analgesia. INT J OBSTET ANESTH, 14, 288-293, 2005. 3. Bromage, P. R., A comparison of the hydrochloride and carbon dioxide salts of lidocaine and prilocaine in epidural analgesia. ACTA ANAESTHESIOL SCAND SUPPL, 16, 55-69, 1965. 4. Capogna, G., Celleno, D., Fusco, P., Lyons, G., Columb, M., Relative potencies of bupivacaine and ropivacaine for analgesia in labour. BR J ANAESTH, 82, 371-373, 1999. 5. Capogna, G., Celleno, D., Lyons, G., Columb, M., Fusco, P., Minimum local analgesic concentration of extradural bupivacaine increases with progression of labour. BR J ANAESTH, 80, 11-13, 1998. 6. Chua, N. P., Sia, A. T., Ocampo, C. E., Parturient-controlled epidural analgesia during labour : bupivacaine vs. ropivacaine. ANAESTHESIA, 56, 1169-1173, 2001. 7. Evron, S., Glezerman, M., Sadan, O., Boaz, M., Ezri, T., Patient-controlled epidural analgesia for labor pain : effect on labor, delivery and neonatal outcome of 0.125% bupivacaine vs 0.2% ropivacaine. INT J OBSTET ANESTH, 13, 5-10, 2004. 8. Gautier, P., De Kock, M., Van Steenberge, A., Miclot, D., Fanard, L., Hody, J. L., A double-blind comparison of 0.125% ropivacaine with sufentanil and 0.125% bupivacaine with sufentanil for epidural labor analgesia. ANESTHESIOLOGy, 90, 772-778, 1999. 9. Halpern, S. H., Breen, T. W., Campbell, D. C., Muir, H. A., Kronberg, J., Nunn, R., Fick, G. H., A multicenter, randomized, controlled trial comparing bupivacaine with ropivacaine for labor analgesia. ANESTHESIOLOGY, 98, 1431-1435, 2003. 10. Halpern, S. H., Walsh, V., Epidural ropivacaine versus bupivacaine for labor: a meta-analysis. ANESTH ANALG, 96, 1473-1479, 2003. 11. Lacassie, H. J., Columb, M. O., Lacassie, H. P., Lantadilla, R. A., The relative motor blocking potencies of epidural bupivacaine and ropivacaine in labor. ANESTH ANALG, 95, 204-208, 2002. 12. Lee, B. B., Ngan Kee, W. D., Ng, F. F., Lau, T. K., Wong, E. L., Epidural infusions of ropivacaine and bupivacaine for labor analgesia : a randomized, double-blind study of obstetric outcome. ANESTH ANALG, 98, 1145-1152, table of contents, 2004. 13. Owen, M. D., Thomas, J. A., Smith, T., Harris, L. C., D Angelo, R., Ropivacaine 0.075% and bupivacaine 0.075% with fentanyl 2 µg/ml are equivalent for labor epidural analgesia. ANESTH ANALG, 94, 179-183, 2002. 14. Polley, L. S., Columb, M. O., Ropivacaine and bupivacaine : concentrating on dosing! ANESTH ANALG, 96, 1251-1253, 2003. 15. Polley, L. S., Columb, M. O., Naughton, N. N., Wagner, D. S., van de Ven, C. J., Relative analgesic potencies of ropivacaine and bupivacaine for epidural analgesia in labor : implications for therapeutic indexes. ANESTHESIOLOGY, 90, 944-950, 1999. 16. Writer, W. D., Stienstra, R., Eddleston, J. M., Gatt, S. P., Griffin, R., Gutsche, B. B., Joyce, T. H., Hedlund, C., Heeroma, K., Selander, D., Neonatal outcome and mode of delivery after epidural analgesia for labour with ropivacaine and bupivacaine : a prospective meta-analysis. BR J ANAESTH, 81, 713-717, 1998.