Translucency of Human Dental Enamel

Similar documents
Translucency of Dental Porcelains

TRANSMITTANCE CHARACTERISTICS OF DIMETHACRYLATE RESIN BASED DENTAL COMPOSITES

Anisotropy of Tensile Strengths of Bovine Dentin Regarding Dentinal Tubule Orientation and Location

Patient demand for esthetic dentistry

Near-UV light detection

A clinical case involving severe erosion of the maxillary anterior teeth restored with direct composite resin restorations

TECHNICAL GUIDE. For use with CEREC

Continually Fluoride Releasing Aesthetic Dental Restorative Material

how to technique Issue How to improve the longevity of porcelain veneers.

Esthetic restorations require that the shade, Applied. Comparative Translucency of Esthetic Composite Resin Restorative Materials ABSTRACT

Dentium Workflow Solution for Labs

Frictional Behavior and Surface Failure of Human Enamel

CLINICAL GUIDE CLINICAL GUIDE. by DR. NOBORU TAKAHASHI BY DR. NOBORU TAKAHASHI

Contouring vs. Orthodontics. Contouring to Eliminate Fractures and Enhance Proportions

Introduction to Layering with Filtek Supreme Plus Universal Restorative. Filtek. Supreme Plus Universal Restorative

In nitro bond strength of cements to treated teeth

Change the Way You Think About Bulk Fill Composites

Direct composite restorations for large posterior cavities extended range of applications for high-performance materials

Fluorescent Properties of Porcelain-Restored Teeth and Their Discrimination

Supporting Information

In Vitro and In Vivo Evaluations of Three Computer-Aided Shade Matching Instruments

Lect. 3 operative Dr. Ameer AL-Ameedee

Ceramic Based Aesthetic CAD/CAM Restorative

THE CLASSIC COMPOSITE FOR EXQUISITE ESTHETICS

Temperature Measurements During Dental Cutting Using an Internally Cooled Diamond Dental Bur

In vitro Accelerated Aging of Composites and a Sealant

Anterior Esthetic Techniques & Materials

Posterior Adhesive Dentistry

ON THE MICROHARDNESS AND YOUNG S MODULUS OF HUMAN TEETH

Opacity and Color Changes of Light-Cured Ideal Makoo (IDM)

Capillary Action Around Dental Structures

Natural Tooth Pontic using Fiber-reinforced Composite for Immediate Tooth Replacement

CERASMART. The new leader in hybrid ceramic blocks

5Recommended Shade-Matching Protocol

Top Finisher System Instructions for Use

Metal-Free Restorations PROCEDURES FOR POSTERIOR DIRECT & SEMI-DIRECT COMPOSITE RESTORATIONS D I D I E R D I E T S C H I. For.

ADHESIVE RECONSTRUCTION IN HELP OF THE ORTHODONTIC TREATMENT

UTML Ultra Translucent Multi-Layered STML Super Translucent Multi-Layered ML Multi-Layered HTHigh-Translucent TECHNICAL GUIDE

Indications The selection of amalgam as a restorative material for class V cavity should involve the following considerations:

Developed to make a difference

Restorative Dentistry and it s related to Pulp health. Dr.Ahmed Al-Jobory

Lava Ceram. Overlay Porcelain for Lava Frameworks

Root Surface Protection Simple. Effective. Important.

GENERAL DENTISTRY & COMPREHENSIVE CARE

Introduction to Layering with Filtek Supreme Plus Universal Restorative. Filtek. Supreme Plus Universal Restorative

TOOTH PREPARATION. (Boucher's Clinical Dental Terminology, 4th ed, p239)

Acetate peel technique: a rapid way of preparing sequential surface replicas of dental hard tissues for microscopic examination

أ.م. هدى عباس عبد اهلل CROWN AND BRIDGE جامعة تكريت كلية. Lec. (2) طب االسنان

INFLUENCE OF FOUR DIFFERENT CEMENTS ON

FINISHING AND POLISHING TECHNIQUES: DIRECT COMPOSITE RESIN RESTORATIONS

SHOFU BLOCK & DISK CAD/CAM CERAMIC-BASED RESTORATIVE. Visit or call mm x 12mm x 16mm. 98mm x 14mm. 12mm x 14mm x 18mm

Available online at ScienceDirect. Procedia Engineering 114 (2015 ) st International Conference on Structural Integrity

DH220 Dental Materials

TOOTH - Crown - Lithium disilicate - Retentive preparation - Super- and equigingival - Visible margin - Variolink Esthetic - ExciTE F DSC

EVALUATION OF COLOR CHANGE IN WHITE SPOT LESIONS OF ENAMEL FLUOROSIS USING A RESIN INFILTRATE

Fuji II LC. A Perfect Choice

A Step-by-Step Approach to

Glass ionomer cements in complex oral rehabilitations. A case report.

Creating deluxe aesthetics with direct, layered composite resin veneers

SHOFU BLOCK & DISK CAD/CAM CERAMIC-BASED RESTORATIVE. Visit or call mm x 14mm

MDJ Evaluation the effect of eugenol containing temporary Vol.:9 No.:2 2012

Active Care - Silver Members Minimally invasive treatment of enamel fluorosis white spot lesions

Various composite resins are used in orthodontic

Chapter 5. Investigation of in vitro Dental Erosion by Optical Techniques

TECHNICAL GUIDE KATANA ZIRCONIA MULTI-LAYERED SERIES

Cutting instruments. Instruments

The power of four: Aesthetic treatment in the anterior area.

Unique worldwide: Only a single composite for the entire range of tooth shades

FRACTURE RESISTANCE OF FELDSPATHIC VENEERS WITH DIFFERENT PREPARATION DESIGNS IN VITRO

Five-Fold Reduction of Lasing Threshold near the First ΓL-Pseudogap of ZnO Inverse Opals arxiv: v1 [physics.

International Journal of Engineering Technology and Scientific Innovation PHOTOELASTIC AND FINITE ELEMENT STRESS ANALYSIS OF HUMAN TEETH

This PDF is available for free download from a site hosted by Medknow Publications

Jordi Manauta. Shadeguides Composite onlays. Page 1 of Apr 2012

Criteria for clinical translucency evaluation of direct esthetic restorative materials

The cutting edge of natural beauty KATANA ZIRCONIA MULTI-LAYERED SERIES

AUGUST 2018 OPTIMIZING. Monolithic Translucent Zirconia. Edward A. McLaren, DDS, MDC

Aesthetic layering principle for beautiful anterior restorations

The Effect of Outdoor Weathering on Color Stability of Silicone and Acrylic Resin, Pigments A Comparative Evaluation: An in vitro Study

FIVE THINGS YOU NEED TO KNOW ABOUT GLASS IONOMERS

Restoration of the worn dentition

Acknowledgments Introduction p. 1 Objectives p. 1 Goals p. 2 History of Dental Materials p. 3 The Oral Environment p. 4 Characteristics of the Ideal

Evaluation of Dentin Root Canal Permeability After Instrumentation and Er:YAG Laser Application

Fuji BULK. Robust. Rapid. Remarkable.

Microleakage around zirconia crowns after ultrasonic scaling around their margin

GUIDELINES FOR PROCESSING CELTRA DUO

Clinical evaluation of jacket crowns made of the Estenia indirect composite

Midline Diastema Closure Following Post-Orthodontic Treatment Relapse Using Metal Free Restorations

November Copyright DENTSPLY International

Influence of enamel prism orientations on color shifting at the border of resin composite restorations

GUM COLORS THE AESTHETICS OF PORCELAIN WITH THE BENEFITS OF INNOVATIVE COMPOSITE TECHNOLOGY

VITA ENAMIC Implant Solutions Clinically Proven Force Absorption for Prosthetic and Implant Success

Amaris. You want outstanding esthetic restorations with the WOW-EFFECT

Glass Ionomers. Reputable, Durable, Long Lasting

Selection and arrangement of teeth in rpd

Charisma Topaz PRODUCT INFORMATION. The three - in - one composite solution. Heraeus Kulzer Nordic AB

Used Products. Variolink N LC. Proxyt fluoride-free. OptraStick. Ivoclean. Monobond N. OptraDam. N-Etch. Tetric N-Bond.

Dr.Adel F.Ibraheem Partial Veneer Crown(Three quarter crown) Three quarter (¾ )crown: Uses: Indications ---- For posterior teeth ;

Effect of enamel margin configuration on color change of resin composite restoration

Clinical Guideline. for full contour zirconia restorations produced chairside with CEREC Zirconia (milling process).

Assessment of Color Changes in Vita 3D-Master Shade Guide after Sterilization and Disinfection

Transcription:

Translucency of Human Dental Enamel R.H.W. BRODBELT, W.J. O'BREN, P.L. FAN, J.G. FRAZER-DB, and R. YU Surface Science Laboratory, Dental Research nstitute, University of Michigan, Ann Arbor, Michigan 48109 Translucency of human dental enamel was determined by total transmittance of wavelengths from 400 to 700 nm. The transmission coefficient at 525 nm was 0.481 mm-1. Total transmission of light through human dental enamel increased with increasing wavelength. Human tooth enamel is more translucent at higher wavelengths. The translucency of wet human enamel and enamel after dehydration was also measured by total transmittance. The transmission coefficient at 525 nm decreased from 0.482 to 0.313 mm-1 after dehydration and was reversed on rehydration. The decrease in translucency occurred as a result of the replacement of water around the enamel prisms by air during dehydration. J Dent Res 60(10):1749-1753, October 1981 ntroduction. The appearance of a natural tooth is a combination of its optical properties. The esthetics of a restoration depend on its resemblance to the natural tooth structure. Shade selection and color parameters of dental materials have been subjects of investigation.14 Optical properties of tooth structures are also used in oral diagnosis and caries detection.5-7 Although the optical properties of human dental enamel form the basis for esthetics matching and caries detection, only some of its optical properties have been determined.8 Translucency is the relative amount of light transmitted through a material. One method of measuring translucency is by determining total transmission, including scattering, using a spectrophotometer with an integrating sphere. Translucency of a material can be expressed as a transmission coefficient, tc, as the relative amount of light passing through the unit thickness of the material.9 The transmission coefficients Received for publication October 21, 1980 Accepted for publication March 15, 1981 This study was supported by research funds from Dental Research nstitute Award DE-02731-14 from the National nstitute of Dental Research, National nstitutes of Health, Bethesda, MD 20205. for dental porcelain have been reported by Brodbelt et al.10 The purpose of the first part of this investigation was to determine the transmission coefficients of wet human dental enamel at different wavelengths. Spiter and ten Bosch stated that between five min and 48 h after the human enamel samples were taken out of the water, there was no influence of water content on optical measurements of both total reflectance and transmission.8 Boorsboom, ten Bosch, and ten Cate also stated that their human enamel samples, which had been stored in water and then allowed to dry, showed a 10% increase in reflectance for the first 20 min, thereafter showing a 1.5% increase per h.11 The authors of these two latter papers observed the influence of water content on the sample of human enamel within the first few min of drying time, but chose to make their investigations in the latter, more stable, drying periods. Therefore, they indirectly recognied the immediate unstable period of drying human enamel which occurs just after being removed from its wet environment. Several phenomena occur that influence the optical properties in the shade-taking process, including 1) the effect of film thickness on surface reflection; 2) the effect of water on bulk translucency; and 3) the effect of water content below the tooth surface. t was the purpose of the second part of this study to investigate the effect of dehydration and rehydration on the translucency of human dental enamel. This would have clinical significance in determining the optimal conditions for shade matching and caries detection by transillumination. Materials and methods. Wet enamel. - Thirty-six disks of human dental enamel, approximately 8.5 mm in diameter and 1 mm thick, were cut from labial surfaces of extracted maxillary central incisors. The teeth were selected at random, provided they were of substantial sie and without restorations, fractures, or caries. 1749

1750 BRODBELTETAL. J Dent Res October 1 981 The labial enamel of each tooth was reduced to a circular outline of about 8.5 mm diameter by use of a diamond bur. The surface was polished using a metallurgical polishing wheel and 600-grit silicon carbide paper.* The tooth was then mounted for sectioning by a low speed saw.t Care was taken not to leave dentin on the sample disks. The samples were then stored in distilled water at room temperature. The average thickness of each sample was obtained by measuring at five points within an external diameter of 6 mm, using a micrometer with point contacts. A spectrophotometer with an integrating sphere assembly was used for transmission measurements. The sample holder described by Brodbelt et al.10 was modified to allow immersion of the samples in distilled water during measurement. Three concentric brass tubes, the smallest having an internal diameter of 6.2 mm, were used to hold the sample in place, as well as to eliminate light leakage at the edge of the sample. The rings also maintained a standard area of 30.2 mm2 for all samples during transmission measurements. The sample chamber was covered by glass slides to provide an aqueous environment for the enamel samples. For total transmission measurements, the samples were placed at the entrance port of the integrating sphere. Barium sulfate standards were used to complete the integrating sphere (Fig. 1). The intensity of the beam passing through the samples was continuously recorded for wavelengths from 400 to 700 nm. A transmission spectrum and digital data record were obtained for each measurement with the light beam entering the samples from the labial surface. Four measurements were made with each sample rotated 90 from the previous measurement. f tc is the transmission coefficient or fractional amount of incident radiation transmitted through unit thickness of material, then the optical transmission (/o) through a thickness of x units of material is given by the equation:9 *Wet-or-dry Tri-M-ite Paper 600 P54, 3M Company, St. Paul, MN 55101 tsomet 11-1180 Low Speed Saw, Buehler, Ltd., Evanston, L 60204 Beckman Acta C- UV-visible Spectrophotometer, Beckman nstruments, nc., rvine, CA 92664 ' /,T\ *-BARUM NCDENT L.T J -, SULFATE / \ DREFLECTANCE J NCDENT ^_LGHT_» SAMPLE STANDARD Fig. 1 - Schematic diagram for measuring translucency of dental enamel using a spectrophotometer with an integrating sphere. /o = tcx. Eq. 1 The values of the transmission coefficient were calculated for each sample at wavelengths of 425, 525, 625, and 700 nm. The 95% confidence limits for the transmission coefficients were calculated at these four wavelengths. 12 Dehydrated enamel. - Six samples of human dental enamel, used for translucency determinations, were selected for this investigation. To simulate the clinical conditions of air drying teeth undergoing restorative treatment, a ten-second air drying with oilfree compressed air was used. For controlled desiccation, a desiccator with silica gel was used. Each sample was placed at an angle against a glass slide exposing all surfaces to dehydration. Three sequential desiccation periods of 15 min were used to simulate an average dental office treatment. Rehydration of enamel samples was done by immersion in distilled water for at least 48 h. Total transmission measurements were performed using the spectrophotometer with an integrating sphere which was used earlier for wet enamel. Wet enamel samples were measured with water in the sample chamber of the holder. Dehydrated enamel samples were measured with air in the sample chamber, and the transmission coefficients were calculated using Equation 1. The relative translucency at different degrees of dehydration was calculated for each sample using the equation: tc relative translucency --- x 100. Eq. 2 tc (wet) The relative translucency of wet enamel was taken as 100.

Vol. 60 No. 10 TRANSLUCENCY OF HUMAN DENTAL ENAMEL 1751 Results. Wet enamel. - A representative transmission spectrum of human dental enamel is shown in Fig. 2. All enamel samples showed increasing transmission with increasing wavelength from 400 to 700 nm. The mean values of transmission coefficient and confidence intervals at the four wavelengths are listed in Table 1 and are shown graphically in Fig. 3. Representative transmission spectra of human dental enamel at different degrees of dehydration are shown in Fig. 4. The transmission coefficients and relative translucency are listed in Tables 1 and 2, respectively. Graphical presentations are shown in Fig. 5. An analysis of variance showed that there were significant differences in mean values at p < 0.05. Multiple comparisons were made using the Student- Newman-Keuls test12 at a = 0.05. The translucency of human dental enamel was significantly altered by dehydration and was fully restored by rehydration. There was no significant difference in the translucency of dental enamel dehydrated in a desiccator for 15, 30, and 45 min. However, these translucency values were significantly lower than those of dental enamel dehydrated by a tensecond exposure to a compressed air stream. 0uC 100. 75.. 50. 25. - HUMAN ENAMEL BASELNE SAMPLE r_ -8 Y.o 400 500 600 WAVELENGTH nm Fig. 2 Transmission - dental enamel. spectrum of human TABLE 1 TRANSMSSON COEFFCENTS OF WET HUMAN DENTAL ENAMEL AT VAROUS WAVELENGTHS Transmission 95% Confidence Wavelength Coefficient nterval (nm) (mm-1) (mm-1) 425 0.327 (0.030)* 0.322-0.332 525 0.481 (0.039) 0.475-0.488 625 0.578 (0.046) 0.571-0.586 700 0.629 (0.050) 0.621-0.638 *Standard deviations in parentheses. E E a, LJw L- 0 (V) () or H- 0.6 0.5-0.4-0.3-02L v.,- WAVELENGTH (nm) Transmission coefficient of human - Fig. 3 dental enamel at various wavelengths. in V) 100 75 50 2 25 u. Baseline Wet io AiriDried 15 Minute Dessicotion 400 500 600 700 WAVELENGTH (nm) 0 Fig. 4 - Transmission spectra of human dental enamel at different degrees of dehydration. Discussion. The values of the transmission coefficient of human dental enamel were different at wavelengths of 425, 525, 625, and 700 nm. The 95% confidence intervals for the transmission coefficients at these four wavelengths did not overlap, indicating significant differences among the mean values. t was observed that there was no difference in transmission intensity when the incident beam entered a sample either from the labial direction or from the lingual direction. Furthermore, there were no significant

1752 BRODBEL T ETAL. JDent Res October 1981 TABLE 2 TRANSMSSON COEFFCENTS (tc) MM-1 OF DENTAL ENAMEL AT DFFERENT DEGREES OF DEHYDRATON Enamel Condition Wavelength (nm) Wet 0.329 (0.033)* 0.482 (0.047)1 0.580(0.053) 0.633(0.057) Rehydrated (48 h) 0.32 (0.03 0.477 (0.049) 0.570 (0.056) 0.623 (0.059) Ten-second air blast 0.252 (0.053) 0.398 (0.063) 0.473 (0.070) 0.511 (0.072) 15-minute desiccation 0.182 (0.035) 0.321 (0.045) 0.391(0.047) 0.426 (0.046) 30-minute desiccation 0.179 (0.032) 0.316 ( 0.043) 0.419 (0.041) 45-minute desiccation 0.174 (0.034) 0.313 (0.044) 0.381 (0.046) 0.414 (0.046)_ *Standard deviations in parentheses. Values joined by the same line are not statistically different at a = 0.05. 0.5- E 0-4 F- w -03 i 03 LLU 0 02 o (n n, (n 0.1 cr 1 1 L 1 WET 10 SEC 15 MN 30 MN 45 MN REHY- h -100 AR JET 5-DESCCATON-- ORATON Fig. 5 - Transmission coefficients and relative translucency of human dental enamel at different degrees of dehydration. differences in transmission intensities when the samples were rotated through the four 90 orientations. The decrease in transmission coefficient with decreasing wavelengths is most likely due to the increase in light scattering as indicated by the Rayleigh scattering equation. Similar results were reported for dental porcelains.10 The transmission coefficient value of human dental enamel at 700 nm is almost twice that at 425 nm. The transmission coefficient at 525 nm, 0.481 mm-1, is considerably higher than the average transmission coefficient of dental porcelain enamels, 0.268 mm-1, at the same wavelengths. This indicates that the dental porcelain enamels are more opaque and may explain the observation that porcelains lack a natural appearance. The translucency of human dental enamel decreased on dehydration as indicated by the lower transmission coefficient values and the corresponding relative translucency values. Enamel dehydrated in a desiccator reached a steady translucency value after 15 min, since there was no statistically significant difference between the relative translucency values after 15 min and after 45 min of desiccation. At a wavelength of 525 nm, the relative translucency of enamel stored in a desiccator was 67% lower than that of wet enamel. Dehydration of enamel by a ten-second exposure to an air stream was used to simulate clinical treatment. The relative translucency decreased to 82% of that of wet enamel. The use of rubber dams and long operating procedures would cause even more severe dehydration and a greater decrease in translucency. TABLE 3 RELATVE TRANSLUCENCY (tdtc WET) X 100% OF DENTAL ENAMEL AT DFFERENT DEGREES OF DEHYDRATON Enamel Condition Wavelength (nm) Wet 100.0( 0.0)* 100.0(0.0) 100.0(0.0) 100.0 (0.0)1 Rehydrated (48 h) 99.3 ( 4.4) 99.9 (3.9) 99.7 (2.4) 99.8 (2.0)1 Ten-second air blast 76.2 (11.5) 82.3 (8.3) 81.5 (7.4) 80.6 (8.0) 15-minute desiccation 55.0 ( 7.0) 66.7 (5.9) 67.1 (4.8) 67.2 (4.1) 30-minute desiccation 55.8 ( 6.3) 66.5 (4.9) 67.3 (3.8) 67.2 (3.8) 45-minute desiccation 53.0 ( 6.1) 65.8 (4.4) 66.6 (3.0) 66.3 (3.8) *Standard deviations in parentheses. Values joined by the same line are not statistically different at a = 0.05.

Vol. 60 No. 10 TRANSLUCENCY OF HUMAN DENTAL ENAMEL 1753 Enamel in the wet state and in different stages of dehydration showed higher transmission coefficient values at higher wavelengths. This is in accordance with the Rayleigh scattering equation. Similar results on dental porcelain were reported by Brodbelt et al. 10 The relative translucency values were similar at wavelengths of 525, 625, and 700 nm, but were lower at 425 nm. This was probably a result of increased scattering at lower wavelengths. The translucency of dental enamel was shown to be influenced by its degree of dehydration. This could be the result of the replacement of the water around the enamel prisms by air. The effect of scattering in a heterogeneous system, such as enamel prisms surrounded by a fluid medium (e.g., water), is a function of the difference in refractive indices of the two components. The refractive index of dental enamel13 is approximately 1.7. Since the refractive index of refraction of water is 1.33 and that of air is 1.00, a larger difference and greater scattering are produced at an enamel-air interface. Therefore, dehydrated enamel would show a lower translucency as found. Conclusions. Translucency of dental enamel can be expressed as a transmission coefficient, tc, for total (direct and diffused) transmission. The values of tc are dependent on the wavelength of the incident light. The transmission coefficients for dental enamel are higher at longer wavelengths of the visible spectrum. Dehydration resulted in a reduction of translucency values. This decrease in translucency is explained as a result of an increased difference in refractive indices between the enamel prisms and the surrounding medium when water is replaced by air. REFERENCES 1. PRESTON, J.D.: Color in Fixed Prosthodontics, Monograph, Los Angeles, CA: V. A. Wadsworth Hospital, 1974, 18 p. 2. CULPEPPER, W.D.: A Comparative Study of Shade Matching Procedures, J Prosthet Dent 24:166-174, 1970. 3. GRAJOWER, R.; REVAN, A.; and SORN, S.: Reflectance Spectra of Natural and Acrylic Resin Teeth, J Prosthet Dent 36: 570-579, 1976. 4. DENNSON, J.B.; POWERS, J.M.; and KORAN, A.: Color of Dental Restorative Resins, JDent Res 57:557-562, 1978. 5. DOMNKOVC, T.: Total Reflectance in Tooth Substance and Diagnosis of Cracks in Teeth - A Clinical Study, Swed Dent J 1: 163-172, 1977. 6. WRGHT, G.Z. and SMON,.: An Evaluation of Transillumination for Caries Detection in Primary Molars, J Dent Child 39:199-202, 1972. 7. BARENE, J.; LESKE, G.; and RPA, L.W.: The Use of Fiber Optic Transillumination for Detection of Proximal Caries, Oral Surg 36:891-897, 1973. 8. SPTZER, D. and ten BOSCH, J.J.: The Absorption and Scattering of Light in Bovine and Human Enamel, Calcif Tiss Res 17:129-137, 1975. 9. MORGAN, J.: ntroduction to Geometric and Physical Optics, New York: McGraw-Hill Book Company, 1953. 10. BRODBELT, R.H.W.; O'BREN, W.J.; and FAN, P.L.: Translucency of Dental Porcelains, JDent Res 59:70-75, 1980. 11. ten BOSCH, J.J.; BOORSBOOM, P.C.F.; and ten CATE, J.M.: A Nondestructive Optical Method to Study De- and Re-mineraliation of Enamel, J Dent Res Spec ss B:1027, 1979. 12. SOKAL, R.R. and ROHLF, F.J.: Biometry, San Francisco, CA: W. H. Freeman and Co., 1969, p. 139. 13. HOUWNK, B.: The ndex of Refraction of Dental Enamel Apatite, Br Dent J 137:472-475, 1974.