Triglyceride Assay Kit 100 point assay kit Cat# TG-1-NC

Similar documents
Triglyceride Assay Kit-Bulk 5 Plate Kit Cat# TG-5-RB

96-well Serum/Plasma Fatty Acid and Glycerol Kit for the Detection of Both Non-Esterified Fatty Acids and Free Glycerol Cat# GFA-1

Lipolysis Assay Kit for 3T3-L1 Cells Non-Esterified Fatty Acids Detection 100 point assay kit Cat# LIP-2-L1; LIP-2-NC-L1

96-well Serum/Plasma Fatty Acid Kit Non-Esterified Fatty Acids Detection 500 Point Kit Cat# SFA-5

3T3-L1 Adipocyte Lipolysis Assay Kit Fluorescent Detection of Glycerol Cat# LIP-4-L1; LIP-4-NC-L1

Cultured Human Adipocyte Lipolysis Assay Kit for Detection of Both Free Glycerol and Non-Esterified Fatty Acids CAT# LIP-3; LIP-3-NC

Adipocyte Lipolysis Assay Kit for 3T3-L1 Cells: Glycerol Detection Cat# LIP-1-L1; LIP-1-NCL1, LIP-1-L1-F, LIP-1-NCL1DIF

RayBio Human Granzyme B ELISA Kit

Blood Urea Nitrogen Enzymatic Kit Manual Catalog #:

Human Mammary Luminal Epithelial Cells. Manual

RayBio Human Phosphotyrosine BTK ELISA Kit

RayBio Human Phospho-DDR1 (Tyr792) ELISA Kit

Blood Urea Nitrogen Enzymatic Kit Manual Catalog #:

RayBio Human Phospho-DDR1 (Tyr792) and Total DDR1 ELISA Kit

RayBio Human Phospho-DDR2 (Tyr740) and Total DDR2 ELISA Kit

RayBio Human, Mouse and Rat Phospho-NF-kB P65 (Ser536) and Total NF-kB P65 ELISA Kit

Human Apolipoprotein A1 EIA Kit

RayBio Human ENA-78 ELISA Kit

Morinaga Mouse C-peptide ELISA Kit

STAT1 (ps727) (Human/Mouse) ELISA Kit

Total Bilirubin Assay Kit Manual Catalog #:

RayBio Human Thyroglobulin ELISA Kit

Mouse Leptin ELISA Kit Instructions

Human TSH ELISA Kit. User Manual

Aspartate Transaminase (AST) Color Endpoint Assay Kit Manual Catalog #:

Rat Hemoglobin A1c (HbA1c) Kit Instructions

BIOO RESEARCH PRODUCTS. Aspartate Transaminase (AST) Color Endpoint Assay Kit Manual Catalog #:

Human Leptin ELISA Kit

HbA1c (Human) ELISA Kit

STAT3 (py705)/ Pan STAT3 (Human/Mouse/Rat) ELISA Kit

Rat cholesterol ELISA Kit

02006B 1 vial 02006B 1 vial Store at -20 C. Lyophilized recombinant IL-2

RODENT Hepatocytes Care Manual

Human Thyroid-Peroxidase Antibody, TPO-Ab ELISA Kit

TABLE OF CONTENTS GENERAL INFORMATION... 1

Canine Thyroid Stimulating Hormone, TSH ELISA Kit

STAT3 (py705) (Human/Mouse/Rat) ELISA Kit

EliKine Free Thyroxine (ft4) ELISA Kit

Cellulite Treatment Screening Kit Human Adipocyte Lipolysis Assay Free Glycerol Detection

TECHNICAL BULLETIN. Catalog Number RAB0447 Storage Temperature 20 C

Rat C-peptide ELISA. For the quantitative determination of C-peptide in rat serum

Mouse C-Peptide ELISA Kit

LDL (Human) ELISA Kit

Rat Insulin ELISA. For the quantitative determination of insulin in rat serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

Human HIV (1+2) antigen&antibody ELISA Kit

CoQ10(Coenzyme Q10) ELISA Kit

Lipase Detection Kit II (Colorimetric)

EGFR (py1045)/ Pan EGFR (Human) ELISA Kit

Choline Assay Kit (Fluorometric)

For the rapid, sensitive and accurate measurement of Glycerol in cell cultures.

TECHNICAL BULLETIN. Phospho-Akt (pser 473 ) ELISA Kit for detection of human, mouse, or rat phospho-akt (pser 473 ) in cell and tissue lysates

Urinary 8-Isoprostane ELISA kit

Lecithin Cholesterol Acyltransferase (LCAT) ELISA Kit

Cellulite Treatment Screening Human Adipocyte Lipolysis Assay Kit Non-Esterified Fatty Acids Detection Cat# LIP-11

Human Umbilical Vein Endothelial Cell Manual

Morinaga Mouse/Rat Leptin ELISA Kit

Cholesterol/Cholesteryl Ester Detection Kit

TECHNICAL BULLETIN. GLP-1 EIA Kit for serum, plasma, culture supernatant, and cell lysates. Catalog Number RAB0201 Storage Temperature 20 C

Ascorbic Acid Assay Kit Manual Catalog #

Fish follicle-stimulating hormone, FSH ELISA Kit

TNF-alpha ELISA. For Research Use Only. Not For Use In Diagnostic Procedures.

Human Umbilical Cord Blood CD34 + /133+ Progenitor Cell Care Manual

Insulin ELISA. For the quantitative determination of insulin in serum and plasma.

RayBio Maltose and Glucose Assay Kit

Procine sphingomyelin ELISA Kit

For the rapid, sensitive and accurate measurement of Triglyceride in various samples.

Mouse C-peptide ELISA

Bovine Insulin ELISA

RayBio DPP4 Inhibitor Screening Kit

Lipolysis Assay Kit for 3T3-L1 Cells Detection of Both Free Glycerol and Non-Esterified Fatty Acids CAT# LIP-3-L1; LIP-3-NC-L1

Rat C-peptide ELISA. For the quantitative determination of C-peptide in rat serum. For Research Use Only. Not For Use In Diagnostic Procedures.

BIOO LIFE SCIENCE PRODUCTS

Oxytetracycline ELISA Test Kit Manual Catalog #: 1081 Reference #: D

Porcine/Canine Insulin ELISA

Glycerol- 3- Phosphate (G3P) Assay Kit (Colorimetric)

Human CD4+T Cell Care Manual

Auto-absorbance of fish extract and co-factors. IMP + Hx + Ino. Absorbance Blank. Absorbance Blank

ab Creatinine Assay Kit (Colorimetric)

Mouse C-peptide ELISA

Mouse Ultrasensitive Insulin ELISA

Exosome ELISA Complete Kits

Nitrate/Nitrite Assay Kit Manual Catalog #

Protocol. G-LISA Rac1 Activation Assay Biochem Kit : 24 Assays (Absorbance Based) Cat. # BK128-S. cytoskeleton.com. Cytoskeleton, Inc.

RayBio Human PPAR-alpha Transcription Factor Activity Assay Kit

ab ORAC Assay Kit

Tetracycline Plate Kit (for Honey) PN 52254B

OxiSelect Human Oxidized LDL ELISA Kit (OxPL-LDL Quantitation)

Total Phosphatidic Acid Assay Kit

Human Keratinocyte Manual

ab Lipase Activity Assay Kit (Colorimetric)

Mouse Adiponectin Immunoassay Kit

RayBio Acid Phosphatase Activity Colorimetric Assay. Kit. User Manual Version 1.0 May 5, RayBiotech, Inc. Kit Protocol. (Cat#: 68CL-AcPh-S500)

Rat Proinsulin ELISA

Insulin (Porcine/Canine) ELISA

Human cholesterol, CH ELISA Kit

Mouse HBsAg(Hepatitis B Virus Surface Antigen) ELISA Kit

Exosome ELISA Complete Kits

GSI Canine IL-5 ELISA Kit-2 Plates DataSheet

OxiSelect MDA Adduct ELISA Kit

ab65336 Triglyceride Quantification Assay Kit (Colorimetric/ Fluorometric)

Transcription:

Triglyceride Assay Kit 100 point assay kit Cat# TG-1-NC INSTRUCTIN MANUAL ZBM0013.06 STRAGE CNDITINS Reagents A & B, Buffers: Store at 2-8 C. Use reconstituted Glycerol Reagent A within 7 days. Glycerol Standard -20 C ALL ZEN-BI INC PRDUCTS ARE FR RESEARCH USE NLY. NT APPRVED FR HUMAN R VETERINARY USE R FR USE IN DIAGNSTIC R CLINICAL PRCEDURES LIMITED PRDUCT WARRANTY This warranty limits our liability to replacement of this product. No other warranties of any kind, expressed or implied, including without limitation, implied warranties of merchantability or fitness for a particular purpose, are provided by Zen-Bio, Inc. Zen-Bio, Inc. shall have no liability for any direct, indirect, consequential, or incidental damages arising out of the use, the results of use, or the inability to use this product. RDERING INFRMATIN AND TECHNICAL SERVICES Zen-Bio, Inc. 3200 East NC-54 Suite 100 P Box 13888 Research Triangle Park, NC 27709 Telephone (919) 547-0692 Facsimile (FAX) (919) 547-0693 Toll Free 1-866-ADIPSE (866)-234-7673 Electronic mail (e-mail) information@zen-bio.com World Wide Web http://www.zenbio.com Rev. 04.16.14 Page 1 of 9 PATENT PRTECTED (6,153,432)

The contents of this kit are sufficient for the assay of 100 assay points in a 96 well plate format. The only reagents sold separately are Glycerol Reagent A (cat# RGTA-10) and the glycerol standard for the Triglyceride Assay kit (cat# TG-GLYSTAN). For additional reagents or formats, please order our bulk 500 point assay kit (cat# TG-5RB). ITEMS INCLUDED IN THE KIT ITEM DESCRIPTIN UNIT QTY STRAGE Wash buffer BTTLE 50ml 4 C Lysis buffer BTTLE 15ml 4 C Glycerol Reagent A Reagent B TG Glycerol standard Standards Diluent Tray Assay Plates, blank Reconstitute w/ 11.0 ml deionized water prior to use. Store at 4 C. Use reconstituted Reagent A within 7 days. Reconstitute w/ 2.5 ml deionized water prior to use Glycerol @ 1mM [Reconstitute with 400 l Standards Diluent to make the 200 glycerol standard; see page 4 for recommended dilution scheme] Clear polyvinyl tray for multi-channel pipetters BTTLE 11ml 4 C BTTLE 2.5 ml 4 C VIAL 100 l -20 C BTTLE 2.5 ml 4 C EACH 3 ----- 96-well assay plate, blank PLATE 2 ----- ther equipment/reagents required but not provided with the kit: Single-channel pipetter Multi-channel pipetter Plate reader with a filter of 540 nm Tubes to dilute glycerol standards Large gauge needle Rev. 04.16.14 Page 2 of 9 PATENT PRTECTED (6,153,432)

ASSAY PRCEDURE 1. Warm the Wash buffer and Lysis buffer in a 37 o C water bath. 2. Prepare the Reagent B by adding 2.5ml deionized water per bottle and gently invert. D NT VRTEX! Use a pipet to ensure that the powder is completely dissolved. Keep at room temperature. Store in a light protected bottle. Reconstituted Reagent B is stable for 60 days refrigerated (2-8 C); store any remaining solution refrigerated (2-8 C). Bring Reagent B to room temperature. 3. Remove all media from mature human adipocytes. Using about 15 ml of the wash buffer, wash the cells one time with 150 µl wash buffer. Label the disposable tray wash buffer and retain for later use. 4. Remove all Wash buffer. Using a new tray, add 15 l Lysis buffer to each well. Incubate at 37 o C - 50 o C for 20 minutes. 5. After the incubation is complete, visually confirm cell lysis by checking the wells under a microscope. If cells are not fully lysed, incubate another 10 minutes. 6. Add 135 l warm Wash Buffer to each well. 7. Add 20 l Reagent B to each well. It is not necessary to mix at this time, however, gently tap the plate to help mix reagents. Incubate the plate at 37 o C for 2 hours. 8. ne hour prior to the assay, bring the glycerol standard and Reagent A to room temperature. Warm the Standards Diluent to 37 C. Prepare the standard curve as follows: Pipette 400 l of the Standards Diluent into the 1 mm glycerol standard tube provided and mix well by vortexing. This produces a diluted stock glycerol standard of 200. Pipette 250 l of diluent into 6 tubes (not provided). Using the newly diluted stock glycerol solution, prepare a dilution series as depicted below. Mix each new dilution thoroughly before proceeding to the next. The 200 stock dilution serves as the highest standard, and the diluent serves as the zero standard. Rev. 04.16.14 Page 3 of 9 PATENT PRTECTED (6,153,432)

400 l 250 l 250 l 250 l 250 l 250 l 250 l Standards Diluent ST D 200 100 50 25 12.5 6.25 3.125 Note: The above dilution series generates enough volume to perform the standard curve in duplicate. If you wish to perform the standard curve in duplicate, please note that eight fewer data points can be assayed with this kit. 9. Also at this time prepare the Reagent A by adding 11.0 ml deionized water per bottle and gently invert. D NT VRTEX! Use a pipet to ensure that the powder is completely dissolved. Keep at room temperature. If using a Reagent A solution previously prepared and stored at 2-8 C, also bring to room temperature. Make sure there is enough Reagent A from one solution to treat all the points in the assay. It may be necessary to combine solutions. Store in a light protected bottle. Reconstituted Glycerol Reagent A is stable for 7 days refrigerated (2-8 C); store any remaining solution refrigerated (2-8 C). 10. To a blank 96 well plate, add 80 l wash buffer to each well needed for the assay (NTE: do not add Wash Buffer to the wells used for the standard curve). 11. Working with one row or column at a time, mix the lysates very well using a multi-channel pipet. Immediately transfer 20 l per well of the lysates to the corresponding well of the plate containing the wash buffer. This results in a Dilution Factor of 5. 12. Prepare the standard curve. Pipet 100 l of each standard into a well. (NTE: Eight wells are necessary for the curve or sixteen if performing the curve in duplicate. If there are remaining wells on the assay plate, you can utilize the remaining wells. If not, a second plate is included in this kit). 13. Using the third tray, add 100 l Reagent A to samples and standards. Mix by pipetting up and down one time. Incubate at room temperature for 15 minutes. 14. Read at 540 nm using a microtiter plate reader. Rev. 04.16.14 Page 4 of 9 PATENT PRTECTED (6,153,432)

GLYCERL STANDARD CURVE This kit is designed to show relative lipid accumulation of experimental treatments compared to controls. The assay is based on the equation 1 M Triglyceride yields 1M glycerol + Free Fatty Acids The reagent measures the concentration of glycerol released after lysing the cells and hydrolyzing the triglyceride molecules. The triglyceride concentration can then be determined from the glycerol values. Generate standard curve: see example below [D NT use this standard curve to generate your data. This is an example.] Subtract the D value of the 0 standard from all D values including the standard curve. Glycerol (um) D D Dblank Dblank Avg Dblank 0 0.048 0.048 0.048 3.125 0.059 0.058 0.011 0.01 0.059 6.25 0.07 0.07 0.022 0.022 0.070 12.5 0.098 0.098 0.05 0.05 0.098 25 0.127 0.13 0.079 0.082 0.129 50 0.2 0.205 0.152 0.157 0.203 100 0.353 0.362 0.305 0.314 0.358 200 0.649 0.667 0.601 0.619 0.658 slope 0.003 intercept 0.053 R 2 0.9997 y = observed.d. minus the blank x = concentration of glycerol in To calculate x for each y, (i.e. to change the observed.d. into glycerol concentration) use the following equation: y=(slope) times (x) plus intercept y=mx+b so x=(y-b)/m x=(y 0.0006)/0.0014 where 0.0014= slope of the line and 0.0006= y intercept. Be careful to enter the proper sign for the y intercept value as it may be a negative number. Rev. 04.16.14 Page 5 of 9 PATENT PRTECTED (6,153,432)

Any D values greater than the highest standard (200 ) should be suspect. The compound should be re-assayed using a lower dose of the compound at treatment R a dilute solution of the condition medium at the time of the assay. The R 2 value should be equal or greater then 0.98 for the standard curve to be valid. Any R 2 values below 0.98, must have the standard curve run again. Solve for the Total Glycerol concentration (i.e. total triglyceride concentration) for each D. Remember to include the Dilution Factor in the equation. Data is expressed as Glycerol. NTE: Any D values that are negative after the blank is subtracted should be considered to be 0 for the D value. REFERENCES 1. Green, H. and Kehinde,. (1974) Sublines of mouse 3T3 cells that accumulate lipid. Cell 1, 113-116. 2. Hauner, H., et al., (1989) J. Clin. Invest. (84), 1663-1670. 3. Kuri-Harcuch W, Wise LS, Green H. (1978) Interruption of the adipose conversion of 3T3 cells by biotin deficiency: differentiation without triglyceride accumulation. Cell 14:53-58. Rev. 04.16.14 Page 6 of 9 PATENT PRTECTED (6,153,432)

TRUBLESHTING Problem High background or the triglyceride reagent turns a darker color before the assay begins. Suggestions Use clean tray and tips Change pipet tips frequently Edge effects Ensure a saturated humidity in the incubator to prevent evaporation from the outside wells Inconsistent D reading Be careful when pipetting to avoid bubbles. If bubbles persist, burst the bubbles using a large gauge needle prior to reading and read the plate again. Mix the lysates well before transferring the 20 l to the Wash buffer plate. FREQUENTLY ASKED QUESTINS 1. Can I buy the reagents separately? The only reagents sold separately are Glycerol Reagent A (cat# RGTA-10) and the glycerol standard for the Triglyceride Assay kit (cat# TG-GLYSTAN). 2. Can I use another plate format besides 96 well? This kit is designed for the assay of A 96 well plate (100 assay points). We do not have a protocol for other formats. 3. Can I use this kit to measure total triglyceride in other cell lines and other human and non-human cells? Yes. The assay is not species specific. As long as the sample concentration is in the linear range, this kit should be able to detect it. 4. My cells did not lyse. What can I do? If cells are not fully lysed, incubate for another 10 minutes at 37 o C - 50 o C. Sometimes mixing by pipetting up and down several times is necessary for full lysis. 5. I do not have time to complete the assay. Can I freeze the samples? Yes. The cell lysates can be stored at -80 C for a maximum of 7 days. Mix the thawed lysates in the plate by pipetting up and down several times. Allow all reagents and samples to reach room temperature BEFRE adding the Wash Buffer and Glycerol Reagent A to complete the assay. Rev. 04.16.14 Page 7 of 9 PATENT PRTECTED (6,153,432)

A B C D E F G H 1 2 3 4 5 6 7 8 9 10 11 12 APPENDIX A: PLATE LAYUT Rev. 04.16.14 Page 8 of 9 PATENT PRTECTED (6,153,432)

APPENDIX B: PRCEDURE FLWCHART Remove all media from wells. Wash with 150 l Wash Buffer Remove all Wash Buffer from wells and add 15 l Lysis Buffer/well. Incubate 20 minutes at 37 50 o C All media 150 l Wash Buffer 150 l Wash Buffer Add 15 l Lysis Buffer Verify lysis and add 135 l warm Wash Buffer. Mix by pipetting up and down 3 times. Add 135 l warm Wash Buffer Add 20 l Reagent B/well and incubate 2 hours at 37 o C. Add 20 l Reagent B ne hour prior to assay, reconstitute Glycerol Reagent A and prepare standards. Keep all at room temperature. Add 80 l Wash Buffer Add 80 l Wash Buffer to a new plate. Mix lysates and transfer 20 l lysates to the wells containing Wash Buffer. 20 l Transfer 100 l of each standard to a new plate. Standards Add 100 l Reagent A to samples and standards. Incubate 15 minutes at 25 o C (room temperature). Pop the bubbles in each well. GLYCERL REAGENT A An additional blank assay plate may be necessary for the assay of glycerol standards. Measure the optical density of each well at 540 nm using a spectrophotometer plate reader. Rev. 04.16.14 Page 9 of 9 PATENT PRTECTED (6,153,432)