Healthy aging. It s vital.

Similar documents
Prodigy. from GE Healthcare. Most trusted, reliable and best-selling DXA system with one of the largest installed base in the world. gehealthcare.

Lunar idxa. The intelligent DXA. gehealthcare.com

Lunar idxa. The intelligent DXA. gehealthcare.com

Lunar Prodigy Advance

Dual-energy Vertebral Assessment

Introducing the future of DXA. Powerful images. Clear answers. Horizon DXA System

Lunar Prodigy Advance

Advanced Point-of-Care Bone Health Assessment HOLOGIC OSTEOPOROSIS ASSESSMENT

Using GE Lunar DXA to Quantify, Visualize, and Trend Incipient Atypical Femoral Fractures

Prevalence of Osteoporosis p. 262 Consequences of Osteoporosis p. 263 Risk Factors for Osteoporosis p. 264 Attainment of Peak Bone Density p.

2013 ISCD Official Positions Adult

Preliminary technical data

Bone Investigational Toolkit BIT. Biomechanical Bone Integrity Assessment

GE Healthcare 9900 Innovation Drive Wauwatosa, WI U.S.A.

DXA When to order? How to interpret? Dr Nikhil Tandon Department of Endocrinology and Metabolism All India Institute of Medical Sciences New Delhi

Fat Mass. Baseline. (lbs) (lbs) Composition Trend: Total. Aug 17. Apr 17. May 17. Jun 17. Jul 17. Measured Date

EXAMINATION CONTENT SPECIFICATIONS ARRT BOARD APPROVED: JANUARY 2017 IMPLEMENTATION DATE: JULY 1, 2017

QDR Series. Discovery and Explorer Advanced Health Assessment

STRUCTURED EDUCATION REQUIREMENTS IMPLEMENTATION DATE: JULY 1, 2017

The Bone Densitometry Examination

2013 ISCD Combined Official Positions

Bone Densitometry. Total 30 Maximum CE 14. DXA Scanning (10) 7

Interpreting DEXA Scan and. the New Fracture Risk. Assessment. Algorithm

Client Sex Facility Birth Date Height Weight Measured ####, #### #### (not specified) #### #### #### ####

idxa Innovation and dedication GE Healthcare About GE Healthcare:

New Dual-energy X-ray Absorptiometry Machines (idxa) and Vertebral Fracture Assessment

Powerful images. Clear answers.

BRAINLAB ORTHOPEDICS SOFTWARE SOLUTIONS TO IMPROVE PATIENT CARE

PhenX Measure: Body Composition (#020300) PhenX Protocol: Body Composition - Body Composition by Dual-Energy X-Ray Absorptiometry (#020302)

Versana Premier. Care with Confidence. gehealthcare.com

PINPOINTING RADIATION THERAPY WITH THE PRECISION OF MR.

Norland Densitometry A Tradition of Excellence

Effect of Precision Error on T-scores and the Diagnostic Classification of Bone Status

Technical data TECHNICAL DATA

LOGIQ S8 XDclear 2.0. Simply Amazing

Balancing the Risks and Benefits of Osteoporosis Treatment: part I: 3 to 5 years treatment

Bone Densitometry Equipment Operator

Osteoporosis/Fracture Prevention

Sectra Orthopaedic Solutions

Vivid S6. Cardiovascular ultrasound system. GE Healthcare. Davis Medical

Purpose. Methods and Materials

Versana Premier. Care with Confidence. gehealthcare.com

Sarcopenia Assessment

CLINIQCT NO-DOSE CT BONE DENSITOMETRY FOR ROUTINE AND SPECIALIST USE.

Official Positions on FRAX

DELPHI. The standard in point-of-care fracture risk assessment. Now with Image Pro.

The Bone Wellness Centre - Specialists in Dexa Total Body 855 Broadview Avenue Suite # 305 Toronto, Ontario M4K 3Z1

9 Quality Assurance in Bone Densitometry section

GE Healthcare. Total-access ultrasound LOGIQ e compact ultrasound system for general imaging and shared services.

Surgical Technique. Anterolateral and Medial Distal Tibia Locking Plates

Adina Alazraki, MD, FAAP Assistant Professor, Radiology and Pediatrics Emory University School of Medicine Children s Healthcare of Atlanta

Bone Mass Measurement BONE MASS MEASUREMENT HS-042. Policy Number: HS-042. Original Effective Date: 8/25/2008

Bone Mineral Densitometry with Dual Energy X-Ray Absorptiometry

vertaplan the spine surgeon s software vertaplan System for successful reconstruction of the individual sagittal balance

Live Educational Programs

Advanced DXA Using TBS insight

Morphometric Measurements in Radiographic Image Processing in the Assessment of Post Menopausal Osteoporosis

ANATOMIC. Navigated Surgical Technique 4 in 1 TO.G.GB.016/1.0

Powered by. Dedicated MRI

ultrasound your way Sharp images. Easy workflow. Fast support. SonixTablet Mountable ultrasound system with a 19 touch screen

In-vivo precision of the GE Lunar idxa for the measurement of visceral adipose tissue in

Diagnostische Präzision von DXL im Vergleich zu DXA bei pmp Frauen mit Frakturen

HIP SOFTWARE-GUIDED SURGERY

Cross-reference: MP Whole Body Dual X-Ray Absorptiometry (DEXA) to Determine Body Composition MP Bone Mineral Density

PediLoc 3.5mm and 4.5mm Contour Femur Plate Surgical Technique

Head to new heights with your imaging SCANORA 3D

Types of Plates 1. New Dynamic Compression Plate: Diaphyseal fracture: Radius, Ulna, Humerus, Rarely tibia

DXA Best Practices. What is the problem? 9/29/2017. BMD Predicts Fracture Risk. Dual-energy X-ray Absorptiometry: DXA

3 - D i m e n s i o n a l V o l u m e t r i c Q C T B o n e D e n s i t o m e t r y o f t h e H i p a n d S p i n e

Bone Mineral Density Studies in Adult Populations

Clinician s Guide to Prevention and Treatment of Osteoporosis

The Bone Wellness Centre - Specialists in Dexa Scanning 855 Broadview Avenue Suite # 305 Toronto, Ontario M4K 3Z1

Use of DXA / Bone Density in the Care of Your Patients. Brenda Lee Holbert, M.D. Associate Professor Senior Staff Radiologist

POSITIONED FOR SUCCESS

Management of postmenopausal osteoporosis

Osteoporosis. Overview

GE Healthcare. Accomplish more. Voluson 730

Technique Guide. SureLock Distal Targeting Device. C-arm guided targeting for trochanteric fixation nail.

Innovations 2017 & 2018

PediLoc 3.5mm and 4.5mm Bowed Femur Plate Surgical Technique

The Bone Wellness Centre - Specialists in DEXA Scanning 855 Broadview Avenue Suite # 305 Toronto, Ontario M4K 3Z1

LUMBAR IS IT IMPORTANT? S. Tantawy,, M.D.

The Bone Wellness Centre - Specialists in DEXA Scanning 855 Broadview Avenue Suite # 305 Toronto, Ontario M4K 3Z1

The Key to Confidence

SURGICAL TECHNIQUE. Alpine Cementless Hip Stem

Submission to the National Institute for Clinical Excellence on

The Bone Wellness Centre - Specialists in DEXA Scanning 855 Broadview Avenue Suite # 305 Toronto, Ontario M4K 3Z1

Bone Densitometry Radiation dose: what you need to know

denosumab (Prolia ) Policy # Original Effective Date: 07/21/2011 Current Effective Date: 04/19/2017

Based on review of available data, the Company may consider the use of denosumab (Prolia) for the

Download slides:

GE Healthcare. LOGIQ E9 XDclear 2.0. Complete Ultrasound HEAD TO TOE OBESE TO THIN NEONATE TO GERIATRIC

WCHQ Ambulatory Measure Specification Screening For Osteoporosis Measurement Period 07/01/16-06/30/17 Submission Period: 09/05/17-10/20/17

Klinikum rechts der Isar, Munich - Germany plans orthopedic surgeries with medicad

Premium solution for your health

LOGIQ E9 with XDclear

Accuracy of DEXA scanning & other methods for determining BMD.

ADOLESCENT OBESITY: IS IT BAD FOR THE BONES

Cpt code for bone density of hips only

1

Transcription:

GE Healthcare Healthy aging. It s vital. encore 17 The leading edge of DXA applications

This trio of new encore 17 functions will take your clinical assessment capability to the next level. We are pleased to announce the latest upgrade to our encore software that further improves our world-class DXA family of products. With encore v17, you ll particularly benefit from three features that focus on incipient Atypical Femur Fracture, Sarcopenia, and Cybersecurity measures.

encore 17 adds these three crucial functions to your existing system: 1For AFF analysis, a quick (yet thorough) way to quantify focal thickening of the lateral cortex AFFs are an increasing concern for patients and clinicians alike due to the potential connection with long-term Bisphosphonate use. Your encore 17 upgrade offers optional AFF software a potent tool for Prodigy and Lunar idxa systems. This feature allows you to quantify focal thickening of the lateral cortex along the entire femoral shaft to the knee. We have created a Beaking Index, that is a measure of the magnitude of the increase in the cortical width (mm) at the location of the localized periosteal reaction. Beaking is a key to assessing the presence of a potential AFF. This analysis can quickly be run on a single femur scan (for both BMD and AFF); you ll be able to trend the serial measurements graphically, allowing for visualization of any potential AFF sites. It s comprehensive, as well: the software automatically connects with the entire patient database, to offer a comparative analysis with past exams, even your standard proximal femur scans. BMD results from typical femur scans and proximal femurs are equivalent. AFF Analysis For Atypical Femur Fracture Assessment Only

Sarcopenia 2For Sarcopenia, a complete assessment package that allows the use of either a published or custom definition With our aging population, Sarcopenia is a common concern. We ve developed encore s optional Sarcopenia Toolset to facilitate diagnosis and monitoring of Sarcopenia on your Prodigy or Lunar idxa system. It s a comprehensive way to measure and report the patient s Appendicular Lean Mass (ALM) seamlessly with Muscle Strength and Muscle/Physical Performance metrics for a complete, integrated Sarcopenia assessment. From there, you enjoy great flexibility. You can choose between the common published definitions, or create a custom definition, to support your clinical decision-making.

3For improved cybersecurity, a robust suite of built-in safety features that meet federal standards Our DXA Bone Densitometers with encore v17 were designed to meet the cybersecurity control measures as defined in recently published FDA cybersecurity guidance. As a result the cybersecurity vulnerability of our DXA systems is minimized to an acceptable level. Please ask for our Manufacturer Disclosure Statement for Medical Device Security (MDS2). MDS2 is one of most critical documents for you during the procurement stage. MDS2 facilitates the review and analysis of the large volume of security-related information supplied by manufacturers for devices on the customer s inventories. MDS2 also allows medical device manufacturers like GE Healthcare to publish the basic security and privacy properties of a specific medical device including operating systems, type of network connection, the ability of the operator to install Antivirus software, or what PHI (Protected Health Information) is stored on the device and whether it is transient or permanent. GE Healthcare is committed to provide the MDS2 using latest released revision of the form to our customers to ensure customers have the most current information as well. Cybersecurity

A wide set of clinical applications GE Healthcare s Windows -based encore software platform brings speed and automation to today s bone densitometry. Daily testing of multi-point calibration coupled with a large reference population database ensures accurate and precise bone assessments. GE Healthcare s versatile family of bone densitometers provides comprehensive applications covering crucial BMD clinical and research needs: Atypical Femur Fracture (AFF) AFF measurement and analysis provides an x-ray image of the entire femur for both qualitative visual assessment and quantitative measures in order to identify areas of focal thickening along the lateral cortex of the femoral shaft. Color Mapping/ Color Coding Color Mapping can be used to set thresholds on fat %, while color coding can be used to code bone, lean tissue and fat tissue. Sarcopenia Sarcopenia software calculates values based on published definitions and thresholds using measured appendicular lean mass in combination with patient demographics and entered values of muscle strength and physical performance. Lateral Spine Measurement Lateral Spine measurement and analysis provides an estimate of bone mineral density for the lumbar spine. FRAX FRAX 10-Year Fracture Risk provides an estimate of 10-year probability of hip fracture and 10-year probability of a major osteoporotic fracture for men and post-menopausal women ages 40-90 years. Hand Measurement Hand measurement and analysis provides an estimate of the bone mineral density for the hand. Femur/ Dual Femur Measures both single femur or both the femurs in one scan, helping you assess the weakest femur through measuring bone mineral density for the proximal femur. Hip Axis Length (HAL) Measurement of the distance along the femoral neck axis, extending from the bone edge at the base of the trochanter to the bone edge at the inner pelvic brim. Orthopedic Hip Implant Measure the delicate region around the hip implant and visualizes 19 Gruen zones. Forearm Measures radius and ulna, providing additional clinical information on BMD for the distal forearm. This measurement can be taken in both sitting or supine position. BMD Measures the bone mineral density of a preferred skeletal site that can be compared to an adult reference population at the sole discretion of the physician. Generates a reference chart with z-score and t-score. Metabolic Information Provides insight on metabolic information such as Resting Metabolic Rate (RMR) and Relative Skeletal Muscle Index (RSMI) with ability to capture Total Body Water (TBW), Intracellular Water (ICW), & Extracellular Water (ECW). Dual-energy Vertebral Assessment (DVA) Lateral and anterior views of the spine with soft tissue equalization to identify vertebral deformations. Performs both LVA and APVA in one scan. Body Composition Total/Regional Performs total body scan to measure bone mass, lean mass and fat mass. Also measures regional and whole body bone mineral density (BMD), lean and fat tissue mass. Pediatrics Pediatric measurement and analysis feature provides BMD, BMC, fat mass, and lean mass for patients from birth to 20 years old.

A wide set of clinical applications (cont.) CoreScan CoreScan software feature estimates the VAT (Visceral Adipose Tissue) mass and volume within the android region. Small Animal Body Scan Small Animal measurement and analysis is for investigational use on laboratory animals or for other tests that do not involve human subjects. OneScan OneScan performs an AP Spine and Dual Femur exam without repositioning between scans. Practice Management Provides generalpurpose business reporting tools to view existing patient population as well as follow-up on next site visit. OneVision The OneVision feature allows you to set up multiple measurements in one exam. This eliminates keystrokes and improves throughput for customers that routinely perform multiple measurements on each patient. Custom Reference Population Physicians can create a custom reference population and use that population for comparison to your patients results. Orthopedic Knee Orthopedic Knee measurement and analysis provides an estimate of the bone mineral density around knee implants pre and postsurgery. Patient BMD Trending Monitoring tool to view changes in a patient s BMD over time. To view trending results, all of the trended measurements must be from the same site. Multi-User Database Access Allows multiple users to access and analyze data from the same patient database. Trabecular Bone Score (TBS) Provides trabecular bone score based on bone structure assessment of the trabecular region of the bone. LVA Morphometry & Spine Geometry LVA Morphometry measurement and analysis provides an x-ray image of the spine for qualitative visual assessment in order to identify vertebral deformations and estimate vertebral heights (morphometry), while LVA and APVA Spine Geometry measure Cobb angles. QuickView QuickView offers a fast, 10 second spine or femur scan. Measurement and analysis procedures are the same as other scan modes. ScanCheck ScanCheck assists the user in detecting Spine, Femur, Forearm and Total Body abnormalities. AP Spine Provides an estimate of bone mineral density for the lumbar spine. Composer Composer feature provides many pre-generated report formats as well as ability to create custom reports. MirrorImage Scan The MirrorImage function can be used to estimate the total body composition and bone mineral density (BMD) when regions of the body are outside of the scan window by using scanned data from the corresponding region(s) on the opposite half of the body.

Your encore package will continue to offer the comprehensive, user-friendly features you already rely on that provide: Clinical confidence; the precision across a broad range of patient sizes and conditions The productivity-enhancers that keep you cost effective The data management and security you require Just in case you are a few releases of encore software behind, here is an overview of features that we have released over the past couple of years: Feature/SW version 2011 v13 2012 v14 2013 v15 2014 v16 2016 v17 Skeletal Health FRAX Spine Geometry Dose Reporting OneScan JSBMR Ref Ortho Knee Peds TB AFF Body Composition CoreScan Advanced Body Composition Sarcopenia Connectivity DICOM EMR Suppliers ICD-10 Codes Acquisition Database Supine Forearm Peds BMDCS Reference Seated Forearm Over Table Weight NHANES SQL Server MUDBA 40 PC OS/Security W-XP/W7 32 Bit Microsoft Security Patches Microsoft Security Patches Application Access Control W7 64 Bit Cybersecurity Imagination at work 2017 General Electric Company All rights reserved. GE Healthcare reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation. Contact your GE Healthcare representative for the most current information. GE, the GE Monogram, Prodigy, Lunar idxa, and CoreScan are trademarks of General Electric Company. GE Healthcare, a division of General Electric Company. FRAX is a registered trademark of the World Health Organization Collaborating Centre for Metabolic Bone Diseases, University of Sheffield, UK. DICOM is a trademark of the National Electrical Manufacturers Association. Windows is a registered trademark of Microsoft Corporation. GE Medical Systems, Inc., doing business as GE Healthcare. JB40748US