MAMMOGRAPHY QC: MORE THAN PHANTOM IMAGES. Stephanie Schofield RTR QC Technologist Nova Scotia Health Authority

Similar documents
POSITIONING ACR REQUIREMENTS IMAGE REVIEW CATEGORIES DEFICIENCIES IN POSITIONING ACR REQUIREMENTS 3/28/2016 NUMBER 1 REASON FOR ACR FAILURE

Mammography Quality Control: A Refresher

Accreditation Case Review: Mammography and Stereotactic Biopsy

Kish chakrabarti, Ph.D. Senior Physicist CDRH/FDA

The American College of Radiology Digital Mammography QC Manual: Frequently Asked Questions (Revised 12/12/2018; new and updated items in red)

Update on MQSA and Mammography Accreditation

Overview. ACR Accreditation Update in Mammography. New ACR Activities. Requirements Today. What s New For Tomorrow. ACR: Recognized by FDA and CMS

Automating Quality Assurance Metrics to Assess Adequate Breast Positioning in Mammography

Implementation of a New Tomosynthesis Program: A Physicists Perspective

HISTORY OF MQSA AND ACR

BICOE Breast Imaging Center of Excellence. What is it? - Requirements. National Mammography Database. What do you get? ACR Accreditation in:

Disclosure. Objectives 2/6/ Allina Health System. What Every Technologist Would Like Their Radiologists To Know

6 Reasons Nipple Markers Add Value in Positioning and Image Critique:

AAPM Annual Meeting. ACR Accreditation Update in CT

Overview. ACR Update on FFDM Accreditation. New ACR Activities. QC Today. QC Tomorrow. ACR Breast Imaging Centers of Excellence BICOE

Implementation of the 2012 ACR CT QC Manual in a Community Hospital Setting BRUCE E. HASSELQUIST, PH.D., DABR, DABSNM ASPIRUS WAUSAU HOSPITAL

BICOE Stereotactic Breast Biopsy and Breast Ultrasound Accreditation. Introduction. Educational Objectives

BICOE Stereotactic Breast Biopsy and Breast Ultrasound Accreditation. Introduction. Educational Objectives

ACCREDITATION DOCUMENT THE RADIOGRAPHER

ACR Accreditation Update in MRI

ACR MRI Accreditation: Medical Physicist Role in the Application Process

NONE. Disclosures. Accreditation Update

Update on the ACR FFDM QC Manual

Comparison Study: Impact of Thin Protective Coverlets on Positioning and Tissue Acquisition in Breast Imaging

History of MQSA ACR creates testing procedures Oct Mammography Quality Standards Act Dec 1993 Interim Regulations Oct All mammog

Breast Imaging Essentials

Multicenter Trial, Phase I Assessment of 2-D FFDM Versus Combo of 2-D and 3-D Tomosynthesis in Breast Cancer Screening

Mammography. Background and Perspective. Mammography Evolution. Background and Perspective. T.R. Nelson, Ph.D. x41433

ACR MRI Accreditation Program. ACR MRI Accreditation Program Update. Educational Objectives. ACR accreditation. History. New Modular Program

Session 2: The Role of Specialist Radiology Technologists

Q. Where can I find out if my state currently requires stereotactic breast biopsy accreditation?

Contrast-Enhanced Spectral Mammography

Stephanie Lea BA, BSc, RTR, MAHSR. Canadian Public Health Association Centenary Conference Toronto, Ontario June 14, 2010

Breast positioning system for full field digital mammography and digital breast tomosynthesis system

EXAMINATION CONTENT SPECIFICATIONS ARRT BOARD APPROVED: JANUARY 2017 IMPLEMENTATION DATE: JULY 1, 2017

CT Quality Control Manual FAQs

The American College of Radiology Breast Ultrasound Accreditation Program: Frequently Asked Questions (Revised: July 31, 2017)

Maintaining a quality mammography facility: Overview of ACR and MQSA Requirements and Update on BI-RADS 5 TH Edition

CHAPTER 2 MAMMOGRAMS AND COMPUTER AIDED DETECTION

MRI FAQs. After reading these documents and checking your protocols, you can apply online here:

The Mammography Examination

Hong Kong College of Radiologists Mammography Statement

9/3/2015. New Mammographic Modality Training. Mammographer. Qualified Radiologic Technologist. Tomosynthesis Training

SenoBright Contrast Enhanced Spectral Mammography Technology. Ann-Katherine Carton Sylvie Saab-Puong Matt Suminski

MQSA Physicist Qualifications. Jon J. Erickson, Ph.D., DABR

RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY. L19: Optimization of Protection in Mammography

Mammography. What is Mammography? What are some common uses of the procedure?

Mammographic Accreditation Phantom

Disclosures. Outline. Learning Objectives. Introduction. Introduction. Stereotactic Breast Biopsy vs Mammography: Image Quality and Dose.

IAEA TECDOC 1517 Quality Control in Mammography Software

Routine Quality Assurance Cookbook

Breast Tomosynthesis. What is breast tomosynthesis?

Example 1: How would you evaluate this transducer? What is the most common problem found in ultrasound QC testing? Uniformity is Subjective

Quality Control in Mammography: Results from a study in Recife, Brazil. H. J. Khoury, V. S. de Barros, M. Sampaio

Screening Mammograms: Questions and Answers

CURRENTLY FDA APPROVED ARE FULL FIELD DIGITAL MAMMOGRAPHY SYSTEMS AND FILM SCREEN STILL BEING USED AT SOME INSTITUTIONS

Dental ConeBeam Computed Tomography (CBCT) X-ray Systems

THE DIAGNOSTIC WORKUP: THE TEAM APPROACH

Breast Tomosynthesis An additional screening tool in the fight against breast cancer

Mammography. What is Mammography?

WHAT TO EXPECT. Breast Tomosynthesis An additional screening tool in the fight against breast cancer HOLOGIC. The Women's Health Company

What every woman should know about. Screening Mammograms

Dose reduction in Hologic Selenia FFDM units through AEC optimization, without compromising diagnostic image quality.

The role of quality assurance

ESTABLISHING DRLs in PEDIATRIC CT. Keith Strauss, MSc, FAAPM, FACR Cincinnati Children s Hospital University of Cincinnati College of Medicine

Mdiagnosing breast by using x-ray to both breasts. It

Nuts and Bolts of MRI Physics Tests or Selling Preparation H. Robert A. Bell, PhD. Learning Objectives

BREAST DOSE SURVEYS IN THE NHSBSP: SOFTWARE AND INSTRUCTION MANUAL Version 2.0

The Practice Standards for Medical Imaging and Radiation Therapy

Patient Dosimetry in Mammography and Tomosynthesis:

Medical Physics in the Breast Screening Programme Kath Schofield & Anne McCurrach NSS Medical Physics

ACR Breast MRI Accreditation Program - DRAFT

Hologic Digital Technology Forms Cornerstone For Growing Women s Health Center

TOMOSYNTHESIS: WORTH ALL THE HYPE?

Overview of the 2005 IOM Report Improving Breast Imaging Quality Standards

Blair Radiology Exam Examination Packet

Computerized image analysis: Estimation of breast density on mammograms

1 Course Syllabus + Study Guide for Lecture and Laboratory

Revisiting image quality assessment A revised version PGAI

Breast Imaging Essentials

Contrast Enhanced Spectral Mammography (CESM) Updates

Debbie Childs RDMS, RVT Sonographer Murphy Medical Center Murphy, NC

SURVEY OF MAMMOGRAPHY PRACTICE

Dedicated to Digital Mammography

Mammography: Analysis and Advanced Techniques

Low Dose CT Lung Screening: What is Technically Required?

Digital mammography imaging from Carestream Health solutions for great workflow, productivity, and patient care.

Course Syllabus + Study Guide for Lecture and Laboratory

"Optimal Dose Techniques and Image Quality: Can We Have Both?" Lorusso, J. R., Fitzgeorge, L., Lorusso, D., & Lorusso, E. 2014

Automated Practical System Qualification, Validation and Reporting acc. ASTM E

Steven Tate Nicholas

Breast phantom with silicone implant for evaluation in conventional mammography

ACCREDITATION CASE REVIEW 2: US AND US-GUIDED BIOPSY CRITERIA

Computer-Aided Diagnosis for Microcalcifications in Mammograms

354 Korean J Radiol 9(4), August 2008

Process Improvement: High Quality Breast MRI

Opportunities and Innovations in Digital Mammography John M. Sandrik, Ph.D. GE Healthcare Milwaukee, WI

CASE STUDIES. Population. Compression

Corporate Medical Policy

Diagnostic Medical Physicist Via Christi Hospitals Wichita, Wichita, KS

Transcription:

1 MAMMOGRAPHY QC: MORE THAN PHANTOM IMAGES Stephanie Schofield RTR QC Technologist Nova Scotia Health Authority

Disclaimer 2 I have nothing to disclose.

Outline 3 QC tests for the mammography technologist Quality Flat field Artifact SNR/CNR Phantom Importance of Image Quality (QA) Positioning Review of CARJ article MAP Reviewing Daily quality

Quality 4 Assurance: A system of activities that when implemented will improve patient care Control: a set of specific tests looking for defects that will cause a reactive process The QC tests performed have changed over the years The constant is the mammography technologist

The Mammography Technologist 5 Performs QA every time they image a patient Ensure there are no issues with your equipment that need service Evaluate images: diagnostic vs. repeat Evaluate for artifacts or any issues with images that seem unusual or different. Always seeking ways to improve System, Positioning, Work flow

6 QC Tests Radiation Protection and Quality Standards in Mammography - Safety Procedures for the Installation, Use and Control of Mammographic X-ray Equipment: Safety Code 36

QC in N.S. 7 We have 1 Medical Physicist For the Academic centre and zone We are working on a provincial QC manual. outcomes and processes Currently no provincial QC program Currently, the MAP recommends the frequency of some specific tests AND to ensure you meet the manufacturers specifications. Be kind to your service engineers.

Artifact (flat field) Detection 8 The PMMA: treat it like the fragile beast it is Raw vs. Processed Window (light to black) If processed view on WW/WL that is mid grey appropriate for breast tissue View 1:1 pixel or Magnify Look for: Blotches/streaks Any textured appearances Any observable lines or structures (collimator cut off or ghosting) Black or white pixels An artifact is significant if it mimics or obscures anatomical features.

Artifact 9 Do a calibration and recheck All artifacts should be discussed with service personnel or physicist ASAP

SNR/CNR 10 Signal to Noise Ratio Measure of sensitivity of a system. How good is your signal relative to the background noise. = (Meanbackground - DCoffset) / (SDbackground) Contrast to Noise Ratio Signal intensity differences between two areas =(Meanbackground - Meanmass)/(SDbackground )

SNR/CNR 11 SNR > 40 CNR >2 CNR variation less than 15% 0.4cm 2 ROI in large mass and just outside (manufacturer) For DC offset (check manufactures Manual or physicist report) Use the same kvp RAW!!! (vs. windowed) Record the mean/sd

Recording results 12 Date Initials kvp mas Mean Bkgd. SD Bkgd. Mean Mass SD Mass SNR (>40) CNR (>2) CNR variation QC 05-Jan slc 28 93.1 356.4 5.1 343.1 5.1 60.08 2.61 8%SS 12-Jan KJT 28 97 369.4 5.3 355.4 5.1 60.26 2.64 9%SS 19-Jan DDH 28 96.2 367.1 5.3 355.3 5.4 59.83 2.23 8%SS 26-Jan SLM 28 96.7 370 5.3 357.4 5.3 60.38 2.38 1%SS 02-Feb slc 28 92.6 353 5.3 340.7 5.3 57.17 2.32 3%SS 09-Feb slm 28 96.7 370 5.2 356.1 5.4 61.54 2.67 10%SS 16-Feb slm 28 97.5 369.6 5.2 356.1 5.3 61.46 2.60 8%SS 23-Feb slm 28 96.4 367.5 5.2 354.5 5.3 61.06 2.50 4%SS 01-Mar DDH 28 97.8 371.6 5.2 360 5.2 61.85 2.23 8%SS 08-Mar slm 28 97 367.7 5.2 354.6 5.2 61.10 2.52 5%SS 15-Mar KJT 28 97 370.4 5.3 356.6 5.1 60.45 2.60 8%SS 23-Mar slc 28 96.4 367.4 5.1 353.2 5.3 62.24 2.78 14%SS

CNR: Size matters 13 ROI size Backgrou nd SD Mass SD SNR CNR 0.1cm 2 370.3 5.2 355.6 5.2 61.60 2.83 0.2cm 2 369.9 5.1 356.8 5.4 62.73 2.57 0.3cm 2 370 5.1 357.4 5.4 62.75 2.47 0.4cm 2 370.2 5.2 358 5.5 61.58 2.35 Make sure the same size ROI is used each time.

The phantom 14 Positioning is important ( I have seen it all sorts of directions) Consistent kvp Anode/filter combination that is used clinically Raw Vs. Processed (raw for CNR/SNR, but you may find it easier to do processed)

Phantom Analysis: Did you know? 15 You can get 0.5 points if you see more than half of the next object You lose 0.5 point for an artifact resembling one of the objects You must have a score of 4 fibres 3 specks 3 masses

Fibres 16 What is the score for fibres? 4.5 0.5 = 4 Must minus 0.5 for the fibre-like artifact

Specks 17 What is my score? 3.5 Magnify the specks for better viewing Start with the largest speck group 1 pt for 4+ specks 0.5 pt for 2-3 specks From largest to smallest stop counting when you reach a score of 0 or 0.5 Then subtract 0.5 for any artifact

Mass 18 Mass gets 1 point for correct location and appears generally circular (3/4 of perimeter is visualized) Mass gets 0.5 point if it appears in correct location but does not look circular Stop counting points when you get a score of 0 or 0.5 Subtract any artifact deductions Score??? 3.5

What does Mammography QA look 19 like to you? Reflection of what your role is Bits completed by different people MAP MQSA Radiologist Outcomes Physicists QC Technologists QC

Ask yourself? 20 Are we evaluating and monitoring every aspect of mammography? Are we all doing a good job? How do we know? How do we get better? (if we need to)

MAP 21 Positioning deficiencies Poor visualization of posterior tissues Sagging breast Inadequate amount of pectoral muscle shown on image (not within 1 cm of nipple level) Inadequate inframammary fold (IMF) Non-standard angulation Pectoral muscle concave/thin Breast positioned too high on image receptor Posterior nipple line (PNL) on CC not within 1 cm of MLO PNL Excessive exaggeration on CC Portion of breast cut off Skin folds Other body parts projected over breast There are 12 positioning DEFICIENCIES

Clinical Images: MAP Evaluation 22 Compression Exposure Level Contrast Sharpness Noise Artifact Exam ID They do a great job evaluating the images we send.

2014: MAP Success 23 100% 95% 90% 85% 80% 75% 86% Canada Accreditation Success Rate 92% NS Does this program tell us how technologists perform everyday? Does having accreditation mean we do a great job everyday?

Clinical Image Quality in Daily Practice of Breast Cancer Mammography Screening 24 (Guertin MH et al, 2014) August 2014 the CARJ published a study where two radiologists independently evaluated the clinical image quality of a random subsample of 197 screening mammograms performed in 2004-2005, based on the criteria by CAR (MAP) found that that positioning is not meeting the standards set by the CAR guidelines

Study found 25 Approximately half of the studies failed CAR quality standards (49.7%) Positioning is the largest contributor to a fail 90% of MAP fails were positioning Discovered an association between BMI and quality Little information regarding daily quality, but recommend performance targets Variations between the 2 evaluators

What Can We Learn 26 The MAP evaluates what is considered the best of your images. The standard for this evaluation should be high. 2 sets of images from 1 or 2 technologists The MAP does not expect that every daily Mammography case will be an accreditation case Despite positioning being extremely important we have yet to change how we evaluate it Touchy subject for technologists Must emphasize continuous quality improvement Must focus on the positive of meeting standards or performance indicators and not failing them

Quality Initiative 27 The purpose: to demonstrate our commitment to providing quality imaging at all times. By auditing our work we will be able to quantify how well we do and identify any areas that require improvement. Primary Focus: positioning and image quality equipment issues and patient dose 2 parts random audit technologist submission KEEP IT POSITIVE!!!!

Random Audit 28 8 cases for each technologist (13) Used the positioning deficiencies criteria from MAP Reversed the criteria to the positive Measure successes Yes/no if each image met specific criteria Looking to find how each technologist performs in each criteria over all the images in the audit to identify strengths or weaknesses Collected DICOM header file data: dose, compression thickness and force, MLO angulations, kvp, mas

Data 29 Critique Element Pt ID: RCC LCC RMLO LMLO adequate amount of pectoral muscle shown on image ( within 1 cm of nipple level) yes yes Pectoral muscle convex (not concave/thin) no yes adequate Inframammory fold (IMF) yes yes Breast up and out (not sagging) yes yes MLO angle 50 49 Posterior nipple line (PNL) on CC within 1cm of PNL on MLO yes No No Excessive exaggeration yes yes visualization of posterior tissues yes yes yes yes none or only 1 minor skin folds yes yes yes yes Breast free of other body parts yes yes yes yes free of motion yes yes yes yes free of grid lines yes yes yes yes free of artefacts yes yes yes yes Sharp and no noise yes yes yes yes Comments

DICOM 30 Technical Element RCC LCC RMLO LMLO Unit BSC MG5 Compression thickness 40 41 40 43 Compression force 145 144 137 146 kvp 27 27 27 27 Anode filter W/Rh W/Rh W/Rh W/Rh mas 124 124 127 145 Organ dose 1.6 1.6 1.6 1.8

CC Results 31 Tech PNL within 1cm of MLO No excessive exaggeration 1 88% 100% 2 69% 100% 3 81% 94% 4 88% 100% 5 88% 100% 6 94% 100% 7 69% 100% 8 50% 100% 9 88% 100% 10 69% 100% 11 88% 100% 12 94% 100% 13 88% 100% Average: 81% 100%

MLOs 32 Technologist Adequate pec shown Pec convex or straight Adequate IMF Breast up (not sagging) 1 100% 75% 69% 94% 2 88% 100% 88% 88% 3 94% 81% 81% 100% 4 100% 100% 94% 100% 5 100% 81% 81% 100% 6 94% 94% 89% 100% 7 94% 94% 88% 94% 8 88% 94% 94% 100% 9 100% 81% 81% 100% 10 100% 75% 100% 100% 11 88% 75% 94% 100% 12 88% 88% 81% 94% 13 88% 75% 63% 88% Average 94% 86% 85% 97%

Angles 33 tech min max 1 48 50 2 47 50 3 46 48 4 45 47 5 45 47 6 47 48 7 43 47 8 44 48 9 49 52 10 46 47 11 46 48 12 45 53 13 47 47

Compression 34 180.0 160.0 140.0 120.0 100.0 80.0 60.0 40.0 20.0 0.0 Tech 1 Tech 2 Average Compression Force Tech 3 Tech 4 Tech 5 Tech 6 Tech 7 Tech 8 Tech 9 Tech 10 Tech 11 Tech 12 Tech 13

Technologists Submission 35 The technologists are asked that they submit cases 1-2 times a year that they feel would meet MAP standards. It is important for the technologists to realize that they can achieve these high quality images. Every technologist has this ability You can not meet the standards if you do not know what they are

Is it worth the work?? 36 FDA/MQSA EQUIP: Enhancing Quality Using the Inspection Program 1. Does the facility have procedures for corrective action when clinical images are of poor quality? 2. Does the facility have procedures to ensure that clinical images continue to comply with the clinical image quality standards established by the facility s accreditation body? Image attributes for each technologist and images accepted by each interpreting physician. Documentation and feedback mechanism

Future 37 Structured problem solving using statistical means to verify performance produce better long term solutions.j Papp The Digital DI department Image Quality Scores/Performance Indicators High level analytics: Combining dicom information with quality indicators Looking for root causes MAP critique scores/ MLO angle Dose/density/unit kvp/unit/patient density Compression/tech

Thank you 38 Special Thanks to: Dr. Sian Iles Dr. Judy Caines Elise LeBlanc Elena Tonkopi Dr. Mohamed Abdolell Dr. Jennifer Payne

References 39 ACR AAPM SIIM PRACTICE PARAMETER FOR DETERMINANTS OF IMAGE QUALITY IN DIGITAL MAMMOGRAPHY 2014 NS Breast Screening CAR MAP Digital Accreditation Application Clinical Image Quality in Daily Practice of Breast Cancer Mammography Screening (Guertin, Theberge, Dufresne, Zomahoun, Major, Tremblay, Ricard, Shumak, Wadden, Pelletier, Brisson HC safety Code 36: Mammography Equipment Katherine Steigerwald MAP Coordinator Quality Management in the Imaging Sciences, J Papp FDA website OBSP Digital Mammography QC for the Technologist