HEARTMATE 3 LEFT VENTRICULAR ASSIST SYSTEM

Similar documents
HEARTMATE 3 LVAD WITH FULL MAGLEV FLOW TECHNOLOGY THEIR FUTURE STARTS WITH YOU

HEARTMATE II LEFT VENTRICULAR ASSIST SYSTEM. HeartMate II Left Ventricular Assist Device

LIVING A MORE ACTIVE LIFE. with the HeartMate 3 LVAD for the treatment of advanced heart failure RON. Recipient

Is it time to consider a HEARTMATE LEFT VENTRICULAR ASSIST DEVICE (LVAD)?

Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy with HeartMate 3 (MOMENTUM 3) Long Term Outcomes

A Fully Magnetically Levitated Left Ventricular Assist Device. Final Report of the MOMENTUM 3 Trial

Destination Therapy SO MUCH DATA IN SUCH A SMALL DEVICE. HeartWare HVAD System The ONLY intrapericardial VAD approved for DT.

Mechanical Circulatory Support in the Management of Heart Failure

HeartWare ADVANCE Bridge to Transplant Trial and Continued Access Protocol Update

Disclosures. No disclosures to report

CARDIOMEMS HF SYSTEM HOW TO STAY ABOVE HEART FAILURE: TALKING TO YOUR PATIENT ABOUT THE

BETTER HEART FAILURE MANAGEMENT FROM THE COMFORT OF YOUR HOME

Ventricular Assist Devices for Permanent Therapy: Current Status and Future

Krabatsch et al. Journal of Cardiothoracic Surgery (2017) 12:23 DOI /s

Knowing your treatment options can give you hope for a longer, better life

Ventricular Assist Device: Are Early Interventions Superior? Hamang Patel, MD Section of Cardiomyopathy & Heart Transplantation

EMS and Nursing Considerations in VAD Patient Care

Adverse Event. Adverse Event Status. Please enter the date of the event you are reporting: Please enter a label describing this event:

Intrapericardial Left Ventricular Assist Device for Advanced Heart Failure

QUICK REFERENCE HEARTWARE HVAD PUMP FLOW INDEX

Status of Implantable VADs

End Stage Heart Failure - Time to Bring the Hammer Down

Further devices to treat heart failure

Risk Factors for Adverse Outcome after HeartMate II Jennifer Cowger, MD, MS St. Vincent Heart Center of Indiana

Two-Year Outcomes with a Magnetically Levitated Cardiac Pump in Heart Failure

Continuous Flow Left Ventricular Assist Device Outcomes in Commercial Use Compared With the Prior Clinical Trial

EMS: Care of the VAD Patient. Brittany Butzler BSN RN VAD Coordinator Froedtert and the Medical College of WI

PROVEN. TRUSTED. COMMITTED. HeartWare HVAD System

When to implant VAD in patients with heart transplantation indication. Aldo Cannata Dept of Cardiac Surgery Niguarda Ca Granda Hospital Milano

เอกราช อร ยะช ยพาณ ชย

None. Declaration of conflict of interest

Complications of Left Ventricular Assist Device Chronic Support. Dr. Tal Hasin RMC, Beilinson, Petach-Tiqva, Israel

Adverse Event - Intermacs

Ventricular Assist Device. Lauren Bartlett 10/5/16 BME 281, section 1

AUTOLOGS TM ATLAS ON DEMAND DATA WITH EVERY PATIENT VISIT

CARDIOMEMS HF SYSTEM PATIENT MANAGEMENT CLINICAL QUICK GUIDE

Diagnosis of Device Thrombosis

A Fully Magnetically Levitated Circulatory Pump for Advanced Heart Failure

MCSD Pump Thrombosis : Industry Perspective

Lessons learned from ENDURANCE, ROADMAP, MedaMACS, and how to go forward?

Mechanical Circulatory Support (MCS): What Every Pharmacist Needs to Know!

CHANGING THE WAY HEART FAILURE IS TREATED. VAD Therapy

3/1/2017. Chronic Mechanical Support for Heart Failure. Heart Failure is a major driver of morbidity and mortality in the US 1-7

MEDICAL POLICY SUBJECT: VENTRICULAR ASSIST DEVICES. POLICY NUMBER: CATEGORY: Technology Assessment

Novel Devices for End-Stage Heart Failure

What has INTERMACS Taught Us about Patient Outcomes with Durable MCS? James K. Kirklin, MD

Mechanical Circulatory Support (MCS) in 2017: What is New and Different?

LVAD Complications, Recovery

LVADs as a long term or destination therapy for the advanced heart failure

New ventricular assist devices. FW Mohr Clinical seminar: Devices for severe heart failure ESC congress Stockholm 2010

VAD come Destination therapy nell adulto con Scompenso Cardiaco

Overview of MCS in Bruce B Reid, MD Surgical Director Artificial Heart Program/Heart Transplantation

LVADS IN AMBULATORY PATIENTS CLASS III PATIENT SHOULD UNDERGO LVAD IMPLANTATION

1/21/2016. HeartMate II Indications for Use. Ventricular Assist Device Overview. Jon G. Echterling MSN, CCRN, FNP-BC. Learning Objectives

Understanding the Pediatric Ventricular Assist Device

CONFIRM Rx INSERTABLE CARDIAC MONITOR CONTINUOUS HEART MONITORING LIVE LIFE WITHOUT SKIPPING A BEAT

Adverse Event. Adverse Event Status. version date: 12/10/ of 21. Please enter the date of the event you are reporting:

Left Ventricular Assist Devices (LVADs): Overview and Future Directions

MEDICAL POLICY SUBJECT: VENTRICULAR ASSIST DEVICES

Outpatient Treatment of MCS Patient. F. Bennett Pearce, MD Professor of Pediatrics Med Director Heart Transplant COA

Advances in Advanced Heart Failure Therapies. Disclosures. Management Algorithm for Patients in Cardiogenic Shock

Adverse Event - Pedimacs

Repeated Ramp Tests on Stable LVAD Patients Reveal Patient-Specific Hemodynamic Fingerprint

ISHLT ACADEMY MASTER CLASS IN MECHANICAL CIRCULATORY SUPPORT (MCS)

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

How to mend a broken heart: transplantation or LVAD?

Implantable Ventricular Assist Devices and Total Artificial Hearts. Policy Specific Section: June 13, 1997 March 29, 2013

Pediatric Mechanical Circulatory Support - What to Use

Mechanical assist patient selection, device selection, and outcomes

Modern Left Ventricular Assist Devices (LVAD) : An Intro, Complications, and Emergencies

Recent Trials With Durable LVADs: Is There a Superior Device?

How to Develop a Comprehensive Ventricular Assist Device Program

Bridge to Heart Transplantation

Analysis of Pump Thrombosis in the Intermacs Database

STATE OF OKLAHOMA 2014 EMERGENCY MEDICAL SERVICES PROTOCOLS

Total Artificial Hearts and Implantable Ventricular Assist Devices

Left Ventricular Assist Devices LVAD. North Country EMS Program Agency 3/21/12

Total Artificial Hearts and Implantable Ventricular Assist Devices

LVADs as Destination Therapy: When Best Practice Criteria Meets the Real World

Perioperative Management of the Mechanical Circulatory Support Patient. American Association of Thoracic Surgeons Allied Health Symposium May 4, 2013

Left Ventricular Assist Devices: Physiology, Complications and Emergencies

RESPECT Safety Findings

Fifth INTERMACS annual report: Risk factor analysis from more than 6,000 mechanical circulatory support patients

HEART & VASCULAR CENTER ADVANCES

Andrew Civitello MD, FACC

Yes No Unknown. Major Infection Information

Do we really need an Artificial Heart? No!! John V. Conte, MD, Professor of Surgery Johns Hopkins University School of Medicine

HeartWare ventricular assist system for bridge to transplant: Combined results of the bridge to transplant and continued access protocol trial

Multicenter Evaluation of an Intrapericardial Left Ventricular Assist System

INTRO LEFT VENTRICULAR ASSIST DEVICE (LVAD) ACUTE MCS MECHANICAL CIRCULATORY SUPPORT (MCS)

Ventricular Assist Devices (VADs) and Percutaneous Cardiac Support Systems

07/17/2014. Thursday, July 17, 14

CARDIOLOGY UPDATE Ventricular Assist Devices in Heart Failure: How and When in 2016? Catherine Demers MD, MSc, FRCPC

Artificial Heart Program

Strengthening Your VAD Program

Surgical Options for Advanced Heart Failure

Challenges to MCS Use in the Middle East

Medical Policy. MP Total Artificial Hearts and Implantable Ventricular Assist Devices

The Balancing Act Bleeding and Thrombosis in MCS. Muhammad Adil Soofi

HeartWare HVAD System. Instructions for Use

Transcription:

HEARTMATE 3 LEFT VENTRICULAR ASSIST SYSTEM A New Milestone in LVAD Therapy HeartMate 3 Left Ventricular Assist Device

Introducing the new HEARTMATE 3 LVAD WITH FULL MAGLEV FLOW TECHNOLOGY HeartMate 3 LVAD with Full MagLev Flow Technology delivers better blood handling through meaningful innovation.** 1 VIVIAN HeartMate 3 LVAD Recipient

SETTING A NEW STANDARD FOR HEMOCOMPATIBILITY The HeartMate 3 LVAD with Full MagLev Flow Technology sets a new standard of LVAD performance by significantly improving the hemocompatibility-related adverse event (HRAE) profile. IMPROVED HRAE PROFILE 0 % PUMP THROMBOSIS 1 At the 6-month primary endpoint in the MOMENTUM 3 trial. 1 The HeartMate 3 LVAD addresses the complex interconnectivity of hemocompatibility events by minimizing pump thrombosis without significantly impacting stroke or gastrointestinal bleeding. EXCELLENT 6-MONTH SURVIVAL 1 89 % There is no significant difference between the HeartMate 3 and HeartMate II LVADs with regard to stroke or gastrointestinal bleeding in the MOMENTUM 3 study: 7.9% and 15.9% for the HeartMate 3 LVAD, respectively, vs 10.9% and 15.2% for the HeartMate II LVAD in the MOMENTUM 3 trial at 6 months. 1

Meaningful innovation driven by FULL MAGLEV FLOW TECHNOLOGY Full MagLev Flow Technology is designed to provide better blood handling to minimize complications. UNIQUE HEMODYNAMIC ELEMENTS Frictionless design, with the absence of mechanical bearings, may help to eliminate friction, heat buildup and the potential for thrombus Wide blood flow pathways intended to minimize hemolysis, blood shearing and stasis DESIGNED TO DELIVER MINIMAL PUMP THROMBOSIS 1 LOW HEMOLYSIS 1 REDUCED BLOOD SHEARING AND STASIS 3 Intrinsic pulsatility to enable pump washing and help minimize areas of stasis in the pump SINTERED TITANIUM SURFACES Designed to promote hemocompatibility on blood contacting surfaces inside the pump, generating a hemocompatible surface layer that can reduce the potential for thrombus formation.

FEATURING LEVITATING SELF- CENTERING ROTOR Rotor self-diagnostics are performed tens of thousands of times per second to ensure consistent centering. HeartMate 3 LVAD rotor will remain suspended and centered, regardless of its orientation, even at zero speed.

MAKING A REAL DIFFERENCE in patients lives SIGNIFICANT IMPROVEMENT IN NYHA CLASS 1 77 % PATIENTS IMPROVED to NYHA Class I or II from NYHA Class III or IV (n = 127) at 6 months (p < 0.0001 compared to baseline) SIGNIFICANT IMPROVEMENT IN 6-MINUTE WALK DISTANCE 1 Average 6-minute walk distance in patients implanted with the HeartMate 3 LVAD (n = 114) (P < 0.001 compared to baseline) 1 80% INCREASE IN DISTANCE 164 m (approx. 180 yards) 296 m (approx. 324 yards) Note: One football field = 91 m (100 yards)

MEANINGFUL IMPROVEMENT IN QUALITY OF LIFE 1 Kansas City Cardiomyopathy Questionnaire Overall Score Increase from Baseline 68 % IMPROVEMENT in mean KCCQ score (standard QoL scale) from baseline **** ADVERSE EVENT PROFILE 1 Adverse events through six months for patients implanted with the HeartMate 3 LVAD (n = 151). Device thrombosis 0 0% 0 Hemolysis not associated with pump thrombosis 1 0.7% 1 GI bleeding 24 15.9% 47 Stroke* 12 7.9% 12 Ischemic 8 5.3% 8 Hemorrhagic 4 2.6% 4 Bleeding requiring surgery 15 9.9% 15 Device malfunction requiring reoperation 1 0.7% 1 Driveline infection 18 11.9% 21 RVAD usage 4 2.6% 4

A BETTER EXPERIENCE for clinicians and patients Abbott continues to set new standards with the world s most comprehensive portfolio of innovative, evidence-based solutions for heart failure therapy supported by a deep commitment to the success of your heart failure program. Offers up to 17 hours of battery life for greater patient confidence and convenience Designed for intrapericardial placement Features a thin, mechanical apical cuff lock for quick and easy pump attachment Incorporates a modular driveline that facilitates simple replacement of externalized portion TO LEARN MORE about the HeartMate 3 LVAD with Full MagLev Flow Technology, please contact your Abbott representative or visit www.heartmate3.com. The HeartMate 3 LVAS EMPOWERING THE TRANSFORMATION OF HEART FAILURE From treatment to ongoing patient management, Abbott is committed to working with you to transform heart failure and improve more patient lives. BEAT AS ONE * At the 6-month primary endpoint in the MOMENTUM 3 trial. (MOMENTUM 3 = Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy with HeartMate 3). ** As defined by zero incidence of pump thrombosis in the MOMENTUM 3 trial at 6 months. ***As seen in the MOMENTUM 3 trial. ****Kansas City Cardiomyopathy Questionnaire. 1. Mehra MR, Naka Y, Uriel N, et al; for the MOMENTUM 3 investigators. A fully magnetically levitated circulatory pump for advanced heart failure. N Engl J Med. 2017; 376:440-450. 2. Uriel N, Colombo PC, Cleveland JC, et al. Hemocompatibility-related outcomes in the MOMENTUM 3 trial at 6 months. Circulation. 2017;135(21):2003-2012. 3. Bourque, K., Cotter, C., Dague, C., Harjes, D., Dur, O., Duhamel, J., Spink, K., Walsh, K., and Burke, E. Design Rationale and Preclinical Evaluation of the HeartMate 3 Left Ventricular Assist System for Hemocompatibility. American Society of Artificial Internal Organs 2016; 62:375-383. 4. Park S. J., Milano, C. A., Tatooles, A. J., Rogers, J. G., Adamson, R. M., Steidley, D. E., et al (2012). Outcomes in advanced heart failure patients with left ventricular assist devices for destination therapy. Circulation Heart Failure, 5(2), 241-248. 5. Maltais S., et al. PREVENtion of HeartMate II Pump Thrombosis Through Clinical Management: The PREVENT multi-center study. J Heart Lung Transplant, 2017 Jan;36(1):1-12. Epub 2016 Nov 16. 6. Jorde, U. P., Kushwaha, S. S., Tatooles, A. J., Naka, Y., Bhat, G., Long, J. W.,... & Birks, E. J. (2014). Results of the destination therapy post-food and drug administration approval study with a continuous flow left ventricular assist device: a prospective study using the INTERMACS registry (Interagency Registry for Mechanically Assisted Circulatory Support). Journal of the American College of Cardiology, 63(17), 1751-1757 7. Starling RC, Estep JD, Horstmanshof DA, Milano CA, et al; ROADMAP Study Investigators (2017). Risk Assessment and Comparative Effectiveness of Left Ventricular Assist Device and Medical Management in Ambulatory Heart Failure Patients: The ROADMAP Study 2-Year Results. JACC Heart Fail, 2017 Mar 30. Abbott One St. Jude Medical Dr., St. Paul, MN 55117 USA Tel: 1 651 756 2000 HeartMate3.com St. Jude Medical is now Abbott. Rx Only Brief Summary: Prior to using these devices, please review the User s Manual for a complete listing of indications, contraindications, warnings, precautions, potential adverse events and directions for use. Indications: The HeartMate 3 Left Ventricular Assist System is indicated for providing short-term hemodynamic support (e.g., bridge to transplant or bridge to myocardial recovery) in patients with advanced refractory left ventricular heart failure. Contraindications: The HeartMate 3 Left Ventricular Assist System is contraindicated for patients who cannot tolerate, or who are allergic to, anticoagulation therapy. Adverse Events: Adverse events that may be associated with the use of the HeartMate 3 Left Ventricular Assist System are listed below. Adverse events are listed in anticipated decreasing order of frequency, except for death, which appears first as it is a non-reversible complication: death, bleeding, cardiac arrhythmia, localized infection, right heart failure, respiratory failure, device malfunctions, driveline infection, renal dysfunction, sepsis, stroke, other neurological event (not stroke-related), hepatic dysfunction, psychiatric episode, venous thromboembolism, hypertension, arterial non-central nervous system (CNS), thromboembolism, pericardial fluid collection, pump pocket or pseudo pocket infection, myocardial infarction, wound dehiscence, hemolysis (not associated with suspected device thrombosis), possible pump thrombosis (has not occurred with HeartMate 3 in the MOMENTUM 3 short term clinical study through 180 days). Refer to the User s Manual for detailed indications, contraindications, warnings, precautions and potential adverse events. Indicates a trademark of the Abbott group of companies. 2018 Abbott. All Rights Reserved. 25467-SJM-HM3-0517-0009(1) Item approved for U.S. use only.