Anterior Pelvic Plating and Sacroiliac Joint Fixation in Unstable Pelvic Ring Injuries

Similar documents
Outcome of Surgical Treatment of AO Type C Pelvic Ring Injury

Ali Bakir Al-Hilli. Senior Lecturer Orthopedics and Trauma/ College of Medicine / Baghdad University. THE IRAQI POSTGRADUATE MEDICAL JOURNAL 525

Clinical comparative analysis on unstable pelvic fractures in the treatment with percutaneous sacroiliac screws and

DISTRACTION EXTERNAL FIXATIONS OF PELVIC FRACTURES CAUSED BY A LATERAL COMPRESSION

Is there a clinical benefit of additional tension band wiring in plate fixation of the symphysis?

Unstable fractures of the pelvis treated with a trapezoid compression frame

Pelvic fractures. Dr Raymond Yean, MBBS Surgical SRMO

Posterolateral elbow dislocation with entrapment of the medial epicondyle in children: a case report Juan Rodríguez Martín* and Juan Pretell Mazzini

Percutaneous iliosacral screw fixation in vertically unstable pelvic injuries, a refined conventional method

Hassan R. Mir, MD, MBA, FACS

Surgical Approaches for Fractures and Injuries of the Pelvic Ring

Treatment of Unstable Pelvic Ring Injuries

5/31/2018. Ipsilateral Femoral Neck And Shaft Fractures. Ipsilateral Neck-Shaft Fractures Introduction. Ipsilateral Neck-Shaft Fractures Introduction

Observation on closed reduction and internal fixation with external fixation in treating unstable pelvic fracture.

Fractures of the tibia shaft treated with locked intramedullary nail Retrospective clinical and radiographic assesment

Classification of Pelvis and Aetabulum Injuries

A rare case of spinal injury: bilateral facet dislocation without fracture at the lumbosacral joint

Percutaneous Ilio-Sacral Screw Fixation in Supine Position under Fluoroscopy Guidance.

Stage Operation for Unstable Lumbar Spine Fracture- Dislocation with Incomplete Paraplegia: A Case Series

Functional outcome of acetabular fracture fixation by modified Stoppa s approach

Case Report Intra-Articular Entrapment of the Medial Epicondyle following a Traumatic Fracture Dislocation of the Elbow in an Adult

Pelvic Fractures. AOCP National Course Belfast City Hospital. 11 th June D Swain BSc; FRCSI; FRCS (Orth.)

3D printing-based minimally invasive cannulated screw treatment of unstable pelvic fracture

Sequential Sacral Insufficiency Fracture After Unilateral Pubic Fractures - A Case Report -

ROLE OF COMPUTED TOMOGRAPHY AND 3D RECONSTRUCTIONS IN PELVIC RIM AND ACETABULAR FRACTURES Somasekhar R 1, A. V. K. Adithya 2, Kalra V.

Anterior Stabilisation of Sacroilliac Joint for Complex Pelvic Injuries

Stoppa Approach for Anterior Plate Fixation in Unstable Pelvic Ring Injury

Percutaneous screw fixation for sacral & sacro iliac joint injuries: Case series

Emergent Management of Pelvic Ring Fractures with Use of Circumferential Compression

Pelvic Injuries. Chapter 21

The functional outcome of surgically treated unstable pelvic ring fractures by open reduction, internal fixation

Short Segment Screw Fixation without Fusion for Low Lumbar Burst Fracture: Severe Canal Compromise but Neurologically Intact Cases

Magnetic Resonance Imaging for the Evaluation of Ligamentous Injury in the Pelvis: A Prospective Case-Controlled Study

CASE REPORT. Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report

ASJ. A Rare Hyperextension Injury in Thoracic Spine Presenting with Delayed Paraplegia. Asian Spine Journal. Introduction

Preliminary results of cannulated screw fixation for isolated pubic ramus fractures

Fractures of the Thoracic and Lumbar Spine

factor for identifying unstable thoracolumbar fractures. There are clinical and radiological criteria

Intracanal Sacral Nerve Impingement Following Percutaneous Iliosacral Screw Pelvic Fixation

Using the Starr Frame and Da Vinci surgery system for pelvic fracture and sacral nerve injury

Primary total hip arthroplasty after acetabular fracture using intra-acetabular bended plates

OUTCOME OF MANAGEMENT OF CLOSED PROXIMAL TIBIA FRACTURES IN TERTIARY HOSPITAL OF SURAT Karan Mehta 1, Prashanth G 2, Shiblee Siddiqui 3

Fractures of the Pelvis and Acetabulum

Pseudo-arthrosis repair of a posterior cruciate ligament avulsion fracture

Crescent Fracture-Dislocation of the Sacroiliac Joint: Use of Iliosacral Screws

PELVIC RING FRACTURES: SHOULD THEY BE FIXED?

Failed Extensor Indicis Proprius Tendon Transfer for Extensor Pollicis Longus Tendon Rupture after Distal Radial Fracture

The role of MDCT in the preoperative planning of percutaneous screw fixation of lateral compression type 2 (LCII ) injuries.

CiSE. PHILOS Plate Osteosynthesis in Metaphyseal Fractures of the Distal Humerus through an Anterolateral Approach. Introduction ORIGINAL ARTICLE

ROTATIONAL PILON FRACTURES

Patient Information MIS LLIF. Lateral Lumbar Interbody Fusion Using Minimally Invasive Surgical Techniques

Surgical Care at the District Hospital. EMERGENCY & ESSENTIAL SURGICAL CARE

Sven Märdian, Klaus-Dieter Schaser, Florian Wichlas, and Philipp Schwabe

Complication Rate and Pitfalls of Temporary Bridging External Fixator in Periarticular Communited Fractures

Clinico-radiological outcome of closed reduction and percutaneous fixation of proximal humerus fractures

Open Access Case Report DOI: /cureus.599. Ashok K. Rathod 1, Rakesh P. Dhake 1, Aditya Pawaskar 1

Pelvic Fixation. Disclosures 5/19/2017. Rationale for Lumbo-pelvic Fixation

The Comparison of the Result of Epiduroscopic Laser Neural Decompression between FBSS or Not

분절성쇄골골절의수술적치료와비수술적치료 - 증례보고 -

Jana Chmelová a *, Milan Šír b, Vladimír Ječmínek b

Original Article Clinics in Orthopedic Surgery 2016;8:

Endobutton technique for dynamic fixation of traumatic symphysis pubis disruption

Unstable elbow dislocations: a case report of a new surgical technique

Competence of the Deltoid Ligament in Bimalleolar Ankle Fractures After Medial Malleolar Fixation *

Crossed Steinmann Pin Fixation In Supracondylar Femur Fractures In Adults A Case Series

The sacrum is a complex anatomical structure.

A Clinical Study For Evaluation Of Results Of Closed Interlocking Nailing Of Fractures Of The Shaft Of The Tibia

The study of distal ¼ diaphyseal extra articular fractures of humerus treated with antegrade intramedullary interlocking nailing

Proximal radioulnar translocation associated with elbow dislocation and radial neck fracture in child: a case report and review of literature

EVOS MINI with IM Nailing

Triple Pelvic Osteotomy

Posteromedial approach to the distal humerus for fracture fixation

University of Groningen. Thoracolumbar spinal fractures Leferink, Vincentius Johannes Maria

Subaxial Cervical Spine Trauma Dr Hesarikia BUMS

The Journal of the Korean Society of Fractures Vol.11, No.3, July, 1998

Lumbosacral Fixation Using the Diagonal S2 Screw for Long Fusion in Degenerative Lumbar Deformity: Technical Note Involving 13 Cases

Jin Wan Kim, Youn Soo Hwang, Kyu Pill Moon, Kyung Taek Kim, Joon Yeon Song

IMAGING OF PELVIC FRACTURES AND ASSOCIATED INJURIES C. Craig Blackmore, MD, MPH

The Acute Management of Pelvic Ring Injuries

Functional outcome of open reduction and internal fixation of clavicle fracture

CASE REPORT. Bone transport utilizing the PRECICE Intramedullary Nail for an infected nonunion in the distal femur

Techique. Results. Discussion. Materials & Methods. Vol. 2 - Year 1 - December 2005

ILIZAROV TECHNIQUE IN CORRECTING LIMBS DEFORMITIES: PRELIMINARY RESULTS

Iliosacral Screws Indications. What Injuries Are Amenable? CRPFPP Indications Injured Zones 11/18/2013

Percutaneous fixation of traumatic pubic symphysis diastasis using a TightRope and external fixator versus using a cannulated screw

Primary internal fixation of fractures of both bones forearm by intramedullary nailing

The Treatment of Pelvic Discontinuity During Acetabular Revision

Tibial plateau fractures: four years review at B&B Hospital

The Most Reliable Spinal Solution

10/24/18. Bones. Innominate Bone. Hip Socket (Acetabulum) Ligaments. Pubic symphysis Sacroiliac Ligaments Front (anterior) Back (posterior)

Single-Thread Screw Available in 25-45mm lengths (5mm Increments) Dual-Thread Screw Available in 30-45mm lengths (5mm Increments)

Tibial deformity correction by Ilizarov method

.org. Tibia (Shinbone) Shaft Fractures. Anatomy. Types of Tibial Shaft Fractures

A novel method of treating isolated unicondylar fracture of the head of the proximal phalanx: A case report

Biomechanical and Clinical Evaluation of a New Operative Technique

recovery. Many methods of treatment for fractures of the clavicle had been IJMDS January 2016; 5(1) 991

Fractures and dislocations around elbow in adult

Case Report Pediatric Transepiphyseal Seperation and Dislocation of the Femoral Head

PELVIS & SACRUM Dr. Jamila El-Medany Dr. Essam Eldin Salama

Traumatic posterior hip instability and reconstruction with a femoral head allograft in a young man

Transcription:

Original Article http://dx.doi.org/10.3349/ymj.2012.53.2.422 pissn: 0513-5796, eissn: 1976-2437 Yonsei Med J 53(2):422-426, 2012 Anterior Pelvic Plating and Sacroiliac Joint Fixation in Unstable Pelvic Ring Injuries Won-Sik Choy, Kap Jung Kim, Sang Ki Lee, and Hyun Jong Park Department of Orthopaedic Surgery, Eulji University College of Medicine, Daejeon, Korea. Received: May 31, 2011 Revised: June 12, 2011 Accepted: June 20, 2011 Corresponding author: Dr. Kap Jung Kim, Department of Orthopaedic Surgery, Eulji University College of Medicine, 1306 Dunsan-2 dong, Seo-gu, Daejeon 302-799, Korea. Tel: 82-42-611-3280, Fax: 82-42-259-1289 E-mail: oskkj@eulji.ac.kr The authors have no financial conflicts of interest. Purpose: To analyze the effectiveness of anterior pelvic plating and subsequent percutaneous sacroiliac joint screw fixation in patients with unstable pelvic ring injuries. Materials and Methods: Thirty-two patients were included with twentyone males and eleven females. The mean age was 41 years (range, 19-76). The mean follow-up period was 51 months (range, 36-73). According to AO-OTA classification, there were 11 cases of B2 injuries, 8 cases of B3 injuries, 9 cases of C1 injuries, 2 cases of C2 injuries and 2 cases of C3 injuries. In the posterior lesions, there were 20 cases of sacral fractures and 12 cases of sacroiliac joint disruptions or dislocations. Anterior pelvic plating and subsequent percutaneous sacroiliac joint fixation were performed. Results: The clinical results were 16 cases of excellent, 10 cases of good, 4 cases of moderate and 2 cases of poor functional results. The 2 cases out of 7 moderate reductions had poor functional results with residual neurologic symptoms. The radiological results were 16 cases of anatomic, 9 cases of nearly anatomic and 7 cases of moderate reduction. All patients were healed except 3 cases of nonunion at the pubic ramus. The complications encountered were 3 cases of screw loosening, 2 cases of anterior plate breakage and 1 case of postoperative infection. Conclusion: In patients with unstable pelvic ring injuries, anterior pelvic plating and subsequent percutaneous sacroiliac joint screw fixation may be a useful surgical option. The radiological results and residual neurologic symptoms had effects on its functional results. Key Words: Pelvic ring injuries, anterior pelvic plating, sacroiliac joint fixation INTRODUCTION Copyright: Yonsei University College of Medicine 2012 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non- Commercial License (http://creativecommons.org/ licenses/by-nc/3.0) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited. Unstable pelvic ring injuries are uncommon which are mainly caused by high energy injuries. They result in extensive disruption of the pelvis and high rates of mortality and late morbidity. They are frequently associated with various types of combined injuries. The conservative treatment of these injuries has been disappointing. Early rigid fixation and anatomical reduction of the pelvic ring are recommended to reduce mortality and allow early ambulation. 1 The complicated vertical shear type of injury or an unstable lateral compression injury or external rotational instability requires anatomical reduction, anteriorly and posteriorly. Dis- 422

Treatment of Unstable Pelvic Ring Injuries placed unstable pelvic ring injuries are commonly associated with disruption of the osteoarticular junction of the sacroiliac joint, and stable fixation of sacroiliac joint is technically demanding while the stability of posterior pelvic ring is more important than that of anterior ring. Anterior fixation can be stabilized by plating, which is the method of choice however, the surgical options for fixation of posterior lesion is still controversial. Plating or sacral bars have been widely used for posterior lesion but they need wide exposure which may be susceptible to infection and postoperative complications. In view of these problems, the percutaneous sacroiliac joint screw fixation is far less invasive technique than those of previous options which can be applied to sacroiliac joint disruption and sacral fractures commonly encountered in unstable pelvic ring injuries. The purpose of our study was to evaluate the effective- ness of anterior pelvic plating and subsequent percutaneous sacroiliac joint screw fixation in patients with unstable pelvic ring injuries. MATERIALS AND METHODS Thirty-two patients with unstable pelvic ring injuries who were followed more than 3 years were included. There were 21 males and 11 females with the mean age of 41 years (range, 19-76). The mean follow-up period was 51 months (range, 36-73) (Table 1). The mechanisms of injury were traffic accident in 20, fall from a height in 9 and crashed from falling objects in 3 cases. Seventeen patients (53%) out of 32 patients had associated injuries or other site fractures. Initial radiologic assessments were anterior-posterior and Table 1. Patients Data No. Age Sex F/U months Classification Radiologic result Clinical result 1 38 M 73 B2 Anatomic Excellent 2 41 M 73 C2 Moderate Moederate 3 48 F 68 B2 Anatomic Good 4 44 M 64 C1 Moderate Good 5 31 M 62 B2 Anatomic Excellent 6 41 F 62 C3 Moderate Poor 7 40 F 62 C1 Nearly anatomic Good 8 41 M 62 C1 Anatomic Excellent 9 63 M 60 B3 Anatomic Excellent 10 48 M 55 B2 Anatomic Good 11 31 M 51 B2 Anatomic Excellent 12 29 F 50 B2 Anatomic Good 13 51 M 50 B2 Anatomic Excellent 14 37 M 50 C1 Nearly anatomic Good 15 35 M 49 C1 Moderate Moderate 16 62 F 49 B2 Anatomic Excellent 17 20 F 49 B2 Anatomic Good 18 40 F 49 B3 Anatomic Excellent 19 42 F 49 B2 Anatomic Excellent 20 27 F 47 B3 Anatomic Excellent 21 54 M 47 C1 Nearly anatomic Good 22 19 F 47 B3 Nearly anatomic Excellent 23 40 M 46 B3 Anatomic Excellent 24 36 M 43 B3 Nearly anatomic Excellent 25 64 M 42 C2 Moderate Moderate 26 32 M 41 B3 Nearly anatomic Good 27 30 M 39 C1 Nearly anatomic Excellent 28 34 M 39 C1 Moderate Moderate 29 38 F 38 B3 Anatomic Excellent 30 23 M 37 B2 Nearly anatomic Good 31 76 M 37 C1 Nearly anatomic Excellent 32 49 M 36 C3 Moderate Poor No., number; F/U, follow-up; M, male; F, female. 423

Won-Sik Choy, et al. inlet-outlet views of pelvis. Three dimensional pelvis CT scan was routinely performed to obtain more information about fracture pattern and operative plan. According to AO- OTA classifications, 2 11 cases of B2, 8 cases of B3, 9 cases of C1, 2 cases of C2 and 2 cases of C3. In the posterior lesions, there were 20 cases of sacral fractures (6 in type I and 14 in type II in the Denis 3 classification) and 12 of sacroiliac joint disruptions or dislocations. Six patients had existing neurologic symptoms at the time of injury. The mean duration from injury to surgery was 4.2 days (range, 0-11). Eight patients (25%) were operated within post-injury 24 hours. Twenty-two patients (69%) were operated within post-injury 10 days. We tried to stabilize the pelvic fractures as early as possible. Remaining 2 patients (6%) who were operated post-injury at 11 days were delayed due to severe combined injuries and intolerable conditions for surgery at the time of injury. All patients were operated under general anesthesia on radiolucent table in a supine position. The leg on the injured side was draped freely, and both hips and knees were slightly flexed to relax the iliopsoas muscle. Our preferred surgi- cal approach was the modified Stoppa 4 approach. Modified Stoppa approach is limited, intra-pelvic approach. It leads to access the intra-pelvic aspect of the pelvis and acetabulum which is gained by retraction of the muscular, neurovascular and urologic structures. It offers the direct visualization of medal wall of acetabulum, entire pelvic ring, and sacroiliac joint which facilitates the development and utilization of improved reduction and plating options. Care must be taken not to injure the corona mortis, obturator nerve, and peritoneum. Through this approach, we could open injured site to obtain exact anatomical reduction with the assistance of intra-operative longitudinal traction and closed manipulation. We fixed anterior ring with single pelvic reconstruction plate and tried to fix at least three screws in each fractured segment (Fig. 1). The posterior ring was indirectly reduced after procedure of anterior ring. Percutaneous sacroiliac joint fixation was performed with same patient s position. After obtaining the true lateral view with fluoroscope guide, the entry point of sacroiliac screw was determined at S1 body. Care should be taken not to injure the sacral canal or foramen with guidance A B C Fig. 1. (A and B) Plain radiograph and 3-D reconstructive CT scan of pelvis show bilateral ramus fractures, left-sided sacral fracture (type I) and right-sided iliac fracture. (C) Immediate postoperative X-ray shows anterior pelvic plating and sacroiliac joint screw fixation. Anatomical reduction is obtained. (D) Final radiograph shows well-maintained and complete union with excellent clinical result. CT, computed tomography. D 424

Treatment of Unstable Pelvic Ring Injuries of pelvic inlet and outlet views. After drilling over the guide pin, a single partially threaded cannulated screw (7.0 mm in diameter) with washer was inserted. The screw was long enough to pass the center of the sacral body. The cannulated screw was tightened till the fracture sites were approximately together (Fig. 1). Postoperatively, passive motion of hip up to 45 degrees was started on the second or third day which was increased to 90 degrees over next 7 days. Active hip motions were started thereafter. Partial weight bearing using walking aids was allowed at postoperative 4-6 weeks. Then, full weight bearing began when a bony union was visible. Periodic follow-up radiographs of the anteroposterior, inlet and outlet views were checked at regular intervals of 4 weeks. For radiologic assessments, we used the criteria of Matta and Saucedo 5 grading system. It was graded as anatomic, nearly anatomic, moderate and poor. The location of sacroiliac screw was graded as adequate or inadequate position by intrusion into sacral canal or sacral foramen or not. The clinical result was evaluated according to the criteria of Rommens and Hessmann 6 which was graded as excellent, good, moderate and poor. We defined excellent or good as a satisfactory result and moderate or poor as an unsatisfactory result. Statistical analysis was tested by Fisher s exact test and a p-value less than 0.05 was considered to be statistically significant. RESULTS All fractures except 3 cases were united within postoperative 16 weeks (range, 12-20 weeks). Three non-union occurred at anterior pubic ramus. Among them, 1 case of nonunion (type C2) occurred with a plate breakage. Since it was asymptomatic, further procedure was not needed. The radiological results were 16 cases of anatomic, 9 cases of nearly anatomic and 7 cases of moderate. In the 7 cases of moderate reductions, 2 cases were inadequate reduction of posterior ring with persisting residual neurologic symptoms. The maximum average of displacement was 15.8 mm in 12 cases of sacroiliac joint disruptions or dislocations. It improved to 5.3 mm, postoperatively. The clinical results revealed 26 cases of satisfactory (16 of excellent and 10 of good), and 6 cases of unsatisfactory results (4 of moderate and 2 of poor). In relation to radiological results, 25 cases which were above nearly anatomic reductions had satisfactory results, and 6 cases of moderate reductions had unsatisfactory clinical results (p<0.05). There were 2 cases of residual neurologic symptoms which coincided with unsatisfactory functional results. With regard to postoperative complications, there were 3 cases of screw loosening (2 cases of anterior plate and 1 case of sacroiliac screw), 2 cases of anterior plate breakage and 1 case of postoperative infection. In 2 cases of screw loosening from anterior plate, re-operation was not needed since they were asymptomatic. One case of sacroiliac screw loosening showed mild loosening. Then, further management was not necessary. Among 2 cases of anterior plate breakage, 1 case was combined with non-union. One case of post-operative infection was healed with thorough debridement without plate removal. DISCUSSION The pelvic ring plays many important roles not only in accommodating the intra-pelvic organs but also bearing body weight and providing support to trunk and spinal column. It is, therefore, very essential to stabilize and restore the ovalshaped osseo-ligamentous structure of the pelvic ring. Several authors reported the results of conservative treatment including external fixation and surgical interventions. 6-9 Most of stable pelvic ring injuries do not necessarily need surgical interventions and they are satisfactorily cured with conservative treatment. However, treatment of unstable pelvic ring injuries by conservative treatments needs a long hospital day and can lead to inaccurate reduction with high mortality rate. 10 Surgical treatments, therefore, are advocated since they can promote early rehabilitation and decrease many complications. 11 External fixation can be a kind of good option for pelvic ring injuries, and it can be applied rapidly and early in pelvic ring disruption. However, external fixation alone is not sufficient to stabilize the posterior lesion, and additional method must be needed. Open reduction and internal fixation which is more constructive treatment modality, can result in a satisfactory outcomes. 5,6 In unstable pelvic ring injuries, anterior fixation alone may not be sufficient to reduce the posterior injury, and the additional fixation of the posterior lesion is recommended, especially vertical shear injuries. 12 Sacral bars have many advantages for sacral fractures and sacroiliac joint dislocations. However, there is a risk of over-compression with nerve injury. Furthermore, bilateral ends of 425

Won-Sik Choy, et al. bar are so prominent that it can result in discomfort to patients. 13 Anterior plating of sacroiliac joint can fix sacroiliac joint, however, surgical approach is limited and can injure 5th lumbar nerve root. 14 Posterior plating of sacroiliac joint through posterior approach has the same biomechanical stability as sacral bars, but it can cause adverse effects such as bleeding, wound problem and postoperative infection. The sacroiliac joint screw fixation can be applied to both sacral fractures and sacroiliac joint disruption. It is also minimally invasive technique with percutaneous fixation, and postoperative complications can be minimal. Furthermore, sacroiliac joint screw can be applied after anterior plating without changing patient s position as in our study. To obtain an anatomical reduction of rotationally unstable pelvic ring injury, anterior plating can be a good surgical option. 15 This is also important in vertically unstable pelvic ring injuries, since a satisfactory reduction of the posterior ring is the first step toward an accurate fixation of the sacroiliac screw. We strongly believe that anatomical reduction and satisfactory anterior plating can make sacroiliac joint screw fixation much easier. Unstable pelvic ring injuries have a tendency to re-displace if only the posterior ring is fixed. Anterior plate fixation is known to lower the rate of malunion. 13 Sagi, et al. 16 reported that anterior plating for the vertically unstable pelvis increases the stability of the fixation construct, and that there were no cases of further displacement after initial fixation and high rate of satisfactory results was obtained. We obtained 7 cases of moderate reduction which were all type C pelvic ring injuries. Among them, 6 cases showed unsatisfactory clinical result except 1 case of good result. We believe that severities of initial injury are closely co-related with radiologic and clinical results. 13,17 It has been assumed that residual neurologic symptom is an another causative factor affecting clinical outcome. Denis, et al. 3 reported that nerve injuries of type C pelvic ring injuries are more severe than those in type B. There were 2 cases of persistent residual neurologic symptoms in this study which showed poor clinical results. In conclusion, anterior pelvic plating combined with percutaneous sacroiliac joint screw fixation is effective treatment options for unstable pelvic ring injuries since it has shown a high rate of functional success and a low complication rate. REFERENCES 1. Tile M. Pelvic ring fractures: should they be fixed? J Bone Joint Surg Br 1988;70:1-12. 2. Fracture and dislocation compendium. Orthopaedic Trauma Association Committee for Coding and Classification. J Orthop Trauma 1996;10 Suppl 1:v-ix, 1-154. 3. Denis F, Davis S, Comfort T. Sacral fractures: an important problem. Retrospective analysis of 236 cases. Clin Orthop Relat Res 1988;227:67-81. 4. Hirvensalo E, Lindahl J, Böstman O. A new approach to the internal fixation of unstable pelvic fractures. Clin Orthop Relat Res 1993:28-32. 5. Matta JM, Saucedo T. Internal fixation of pelvic ring fractures. Clin Orthop Relat Res 1989:83-97. 6. Rommens PM, Hessmann MH. Staged reconstruction of pelvic ring disruption: differences in morbidity, mortality, radiologic results, and functional outcomes between B1, B2/B3, and C-type lesions. J Orthop Trauma 2002;16:92-8. 7. Suzuki T, Shindo M, Soma K, Minehara H, Nakamura K, Uchino M, et al. Long-term functional outcome after unstable pelvic ring fracture. J Trauma 2007;63:884-8. 8. Nepola JV, Trenhaile SW, Miranda MA, Butterfield SL, Fredericks DC, Riemer BL. Vertical shear injuries: is there a relationship between residual displacement and functional outcome? J Trauma 1999;46:1024-9. 9. Smith W, Shurnas P, Morgan S, Agudelo J, Luszko G, Knox EC, et al. Clinical outcomes of unstable pelvic fractures in skeletally immature patients. J Bone Joint Surg Am 2005;87:2423-31. 10. Stocks GW, Gabel GT, Noble PC, Hanson GW, Tullos HS. Anterior and posterior internal fixation of vertical shear fractures of the pelvis. J Orthop Res 1991;9:237-45. 11. Burgess AR, Eastridge BJ, Young JW, Ellison TS, Ellison PS Jr, Poka A, et al. Pelvic ring disruptions: effective classification system and treatment protocols. J Trauma 1990;30:848-56. 12. Kellam JF, McMurtry RY, Paley D, Tile M. The unstable pelvic fracture. Operative treatment. Orthop Clin North Am 1987;18:25-41. 13. Keating JF, Werier J, Blachut P, Broekhuyse H, Meek RN, O Brien PJ. Early fixation of the vertically unstable pelvis: the role of iliosacral screw fixation of the posterior lesion. J Orthop Trauma 1999;13:107-13. 14. Leighton RK, Waddell JP. Techniques for reduction and posterior fixation through the anterior approach. Clin Orthop Relat Res 1996:115-20. 15. Tornetta P 3rd, Dickson K, Matta JM. Outcome of rotationally unstable pelvic ring injuries treated operatively. Clin Orthop Relat Res 1996:147-51. 16. Sagi HC, Ordway NR, DiPasquale T. Biomechanical analysis of fixation for vertically unstable sacroiliac dislocations with iliosacral screws and symphyseal plating. J Orthop Trauma 2004;18: 138-43. 17. Pohlemann T, Angst M, Schneider E, Ganz R, Tscherne H. Fixation of transforaminal sacrum fractures: a biomechanical study. J Orthop Trauma 1993;7:107-17. 426