Evaluation of a Digital Measurement Tool to Estimate Working Length in Endodontics

Similar documents
The Effect of X Ray Vertical Angulation on Radiographic Assessment of Alveolar Bone Loss

The influence of sensor size and orientation on image quality in intra-oral periapical radiography

The wonderful world of dental radiology

The wonderful world of dental radiology

Periapical Radiography

Jordan University of Science and Technology Faculty of Applied Medical Sciences Department of Allied Dental Sciences Course Syllabus

Periapical radiography and cone beam computed tomography for assessment of the periapical bone defect 1 week and 12 months after root-end resection

COMMON COURSE OUTLINE: Course discipline/number/title: DS 1300: Dental Radiology

ACADEMY FOR DENTAL ASSISTANTS

Canal length estimation in curved root canals A comparison between conventional and direct digital radiography *Avinash M **Kamath PM

Current Concepts in Caries Management Diagnostic, Treatment and Ethical/Medico-Legal Considerations. Radiographic Caries Diagnosis

DENTAL RADIOLOGY Identify basic facts and terms of radiology, to include fundamentals. with 70% accuracy.

Case Report Treatment of Two Canals in All Mandibular Incisor Teeth in the Same Patient

Working length changes following straight-line access and different coronal flaring methods

The effects of file size, sodium hypochlorite and blood on the accuracy of Root ZX apex locator in enlarged root canals: an in vitro study

Comparison of Working Length Determination Using Apex Locator and Conventional Radiography in Curved Canals an In Vitro Study

Dental Hygiene Spring 2018 Summer 2014 Fall COURSE OUTLINE DHT 1032 Dental Radiography 2 Credit Hours

In vitro comparison of three different image receptors for determining the length of endodontic files

Dental Radiography

Dental Intraoral X-ray Systems

Diagnostic accuracy of conventional radiography and digital radiography in detecting of root fractures (invitro study)

Intraoral Imaging. Chapter 41. Copyright 2018, Elsevier Inc. All Rights Reserved. 1

Limited To Endodontics Newsletter. Limited To Endodontics A Practice Of Endodontic Specialists June Volume 4

Radiation Safety & Determining Need for Radiographs

UNSURPASSED ACCURACY UNRIVALED RELIABILITY Data on file.

Oral and Maxillofacial Radiology

Frank: Merrill's Atlas of Radiographic Positioning & Procedures, 12th Edition

Evidence-based decision-making in endodontics

Proceedings of the World Small Animal Veterinary Association Sydney, Australia 2007

Large periapical lesion: Healing without knife and incision

Jordan University of Science and Technology Faculty of Applied Medical Sciences Department of Applied Dental Sciences 1 st Semester

Common Intra Oral Radiographic Errors Made by Dental Students

In Vitro Comparative Study of the Working Length Determination with Radiovisiography and Conventional Radiography in Dilacerated Canals

Establishment of local diagnostic reference levels for quality control in intraoral radiography

Guided learning hours It is recommended that 15 hours should be allocated for this unit, although patterns of delivery are likely to vary.

Course File 243 DDS Physics of Diagnostic Radiology and Oral and Maxillofacial Radiology

INTER-AMERICAN UNIVERSITY OF PUERTO RICO

In vitro comparison of conventional film and direct digital imaging in the detection of approximal caries

Localization of impacted maxillary canines using panoramic radiography

Effect of Developer Age and Film Speed on Diagnostic Accuracy of Endodontic File Length Measurement on Radiographs

Level 3 Diploma in Dental Nursing

CLINICAL AUDIT OF DENTAL RADIOGRAPHY

COURSE INFORMATION SHEET. HOURS: 3 Credit Hours, 2 Lecture, 3 Laboratory hours a week, 80 Contact Hours

Impact of quality control on radiation doses received by patients undergoing abdomen X-ray examination in ten hospitals

-./ Accuracy of digital panoramic in detection of interproximal caries ! " # 8 9-/ 0 567:: /0 1 :

Periapical radiographic technique errors made with film and phosphor plates

Radiation Safety for Dental Auxiliaries. Susan W. Grammer, RDH, M.Ed. Course Content. A. Radiation History and the Use of Radiographs

The Effect of Bite Registration on the Reproducibility of Parallel Periapical Radiographs Obtained with Two Month Intervals

SYLABUS. Subject: Dental Radiology

Accuracy of Working Length Determination using IOPA Grid Technique and Apex Locator: An In vivo Study

Accuracy of Conventional and Digital Radiography in Detecting External Root Resorption

Patient dose in routine X-ray examinations in Yazd state

Intraoral radiographic techniques Introduction There are three main types of intraoral radiographs: Periapical radiograph Bitewing radiograph

IN VITRO COMPARISON OF TWO ELECTRONIC APEX LOCATORS

Journal of Dental School 2014; 32(1): 23-29

Comparison of conventional radiography with cone beam computed tomography for detection of vertical root fractures: an in vitro study

Unusual root canal anatomy in a maxillary second molar

NEW BRUNSWICK NIHB Regional Dental Benefit Grid Oral and Maxillofacial Surgeons

Administrative-Master Syllabus form approved June/2006 Page 1 of 1

Dental Radiography STANDARDS & GUIDELINES TABLE OF CONTENTS. College of Dental Surgeons of BC

HOUSTON COMMUNITY COLLEGE SYSTEM Coleman College for Health Sciences Dental Assisting Program Fall 2014

A comparative study of cone-beam computed tomography and digital periapical radiography in detecting mandibular molars root perforations

In vitro cone beam computed tomography imaging of periodontal bone

The reduction methods of operator s radiation dose for portable dental X-ray machines

POLICY FOR THE USE AND CONTROL OF IONIZING RADIATION FOR DIAGNOSTIC IMAGING AT THE SCHOOL OF DENTISTRY, UNIVERSITY OF MINNESOTA

Straight to the point with your diagnosis.

NOVA SCOTIA NIHB Regional Dental Benefit Grid Oral and Maxillofacial Surgeons

NEWFOUNDLAND AND LABRADOR NIHB Regional Dental Benefit Grid Oral and Maxillofacial Surgeons

PRINCE EDWARD ISLAND NIHB Regional Dental Benefit Grid Oral and Maxillofacial Surgeons

CHAPTER 3 - DEFINITION, SCOPE, AND INDICATIONS FOR ENDODONTIC THERAPY ARNALDO CASTELLUCCI

Assessment of the relationship between the maxillary molars and adjacent structures using cone beam computed tomography

FRACTURES AND LUXATIONS OF PERMANENT TEETH

WaveOne Gold reciprocating instruments: clinical application in the private practice: Part 2

Nestor Cohenca Professor Department of Endodontics Department of Pediatric Dentistry Diplomate, ABE

Mædica - a Journal of Clinical Medicine. Interobserver variability of the diagnosis of apical periodontitis on panoramic radiography assessment

Radiology. & supporting structures. Lec. 14 Common diseases of teeth Dr. Areej

Introduction. Clinical Periodontal Examination 11/1/16

Digital radiography has

CAMOSUN COLLEGE School of Health & Human Services Dental Programs. DHYG 131 Dental Radiology. Winter, 2013 COURSE OUTLINE

NEW JERSEY RADIOLOGIC TECHNOLOGY BOARD OF EXAMINERS (BOARD) DENTAL RADIOGRAPHY CURRICULUM REQUIREMENTS

SIGNIFICANCE OF WORKING LENGTH IN RCT: A CASE REPORT

NEW JERSEY RADIOLOGIC TECHNOLOGY BOARD OF EXAMINERS (BOARD) DENTAL RADIOGRAPHY CURRICULUM REQUIREMENTS GENERAL REQUIREMENTS

Monday Morning Pearls of Practice by Bobby Baig

A case of apical fenestration misdi Title persistent apical periodontitis. Author(s) Furusawa, M; Hayakawa, H; Ida, A; I

A Comparison of 2D versus 3D Radiography in the Treatment Planning of Root Canal Treated Teeth with Periapical Lesions

Karl Maloney, DDS,* Jairo Bastidas, DMD, Katherine Freeman, DrPH, Todd R. Olson, PhD, and Richard A. Kraut, DDS. Materials and Methods

Accuracy of CBCT as modality to identify the presence of secondary mesiobuccal root canal in the maxillary first molar

Principles of diagnosis in Endodontics. Pain History. Patient Assessment. Examination. Examination 11/07/2014

Assistant Professor, Department of Oral and Maxillofacial Surgery, S.D. Dental College and Hospital, Parbhani, Maharashtra, India, 2

Medical Diagnostic Imaging

Efficacy of Pseudocolor Tool of Digital System in the Detection of Proximal Caries

Horizontal root fracture (HRF) implies a severe injury to cementum, dentin, and pulp

Radiographic Policy *ALL RADIOGRAPHS ARE TAKEN FOR DIAGNOSTIC PURPOSES ONLY

Assessment of the relationship between maxillary sinus floor and maxillary posterior teeth root apices using spiral CT scan

Comparison of Spreader Penetration during Lateral Compaction of 0.04 and 0.02 Tapered Gutta-Percha Master Cones

PREVALENCE OF ROOT ANGULATION IN VIDARBH POPULATION: A PANORAMIC RADIOGRAPHIC STUDY

In vivo accuracy of conventional and digital radiographic methods in confirming root canal working length determination by Root ZX

User Guide for Dental and Maxillofacial Cone Beam Computed Tomography (CBCT)

In vitro Study of Apically Extruded Debris and Irrigant Following the Use of Conventional and Rotary Instrumentation Techniques

Transcription:

Volume 2 Number 1 Winter Issue, 2001 Evaluation of a Digital Measurement Tool to Estimate Working Length in Endodontics Abstract The purpose of the study was to compare the segmental measurement tool from the Shick Technologies CDR digital system with the conventional film radiography measurement technique to determine preoperative working length. Natural extracted human teeth with varying degrees of root curvature were used. All teeth were imaged using the Shick Technologies CDR direct digital system and conventional E-speed film. Measurements from digital radiography and conventional film were compared with measurements made directly from the endodontic files. The Wilks' Lambda multivariate test was used. The mean measurement of each modality was compared with the other and with the gold standard. The test showed statistically significant differences between the two modalities at p<0.05. The mean measurements for both modalities were not significantly dif ferent from the gold standard. The modality most closely approaching the gold standard was the conventional film. Keywords: endodontics Direct digital radiography, Schick Technologies CDR, conventional film, working length, Seer Publishing 1

Figure 2 (Figure 2) The standard geometric configuration was fixed at 40-cm source-to-object distance, 1- cm object-to-receptor distance, and zero degrees vertical and horizontal angulation of the X-ray beam. Figure 1 Introduction Radiology is an essential part of endodontics to ensure successful root canal therapy. It is helpful in estimating and confirming the lengths of root canals and to verify the apical extension of an endodontic file prior to and during instrumentation. Traditionally, the root length is determined initially by measurement of periapical radiographs. However, measurement of roots that 1, 2, 3 are excessively curved is difficult when using this method. With direct digital radiography, segmental measurements may be combined to give the overall working length of a curved root. The accuracy of this segmental measurement tool compared to conventional film measurement techniques has not been tested. Therefore, the aim of this study is to compare the segmental measurement tool from the Shick Technologies CDR digital system with the conventional film radiography measurement technique to determine preoperative working length. (Figure 1) Materials and Methods Twenty extracted human posterior teeth stored at 4 C in 0.9% NaCl containing 0.002% sodium azide were used for this pilot study. Teeth with varying degrees of root curvature were selected. An optical bench was used to reproducibly position the X-ray source, teeth, and image receptor. All teeth were imaged using the Shick Technologies CDR direct digital system and conventional E-speed film. A GE-1000 intraoral X-ray machine was used operated at 70kVp and 10mA. The timer settings that were required to produce comparable densities for both conventional film and digital images were determined by consensus of two oral and maxillofacial radiologists. Timer settings were 5 impulses for the CDR images and 14 impulses for conventional film. All intraoral films were processed at the same time in a Hope P-10 automatic processor for 4.5 min. at 82 F. After the images were obtained, three experienced endodontists measured the working lengths of twenty root canals from digital images using the segmental measurement tool. (Figure 3) The working lengths from the conventional film were measured using an electronic digital caliper Figure 3 2

(Fred Fowler Co., Newton, MA). To determine the actual working lengths, access preparations were made and a K-type size 15 endodontic file was placed in the canals until the file was flush with the apical foramen. Measurements from digital and conventional film were then compared with measurements made directly from the endodontic files. The Wilks' Lambda multivariate test was used. The mean measurement of each modality was compared with the other and with the gold standard. Results The Wilks' Lambda multivariate test showed statistically significant differences between the two modalities at p<0.05. The mean measurements for both modalities were not significantly dif ferent from the gold standard. The modality most closely approaching the gold standard was the conventional film. The majority of measurements made from conventional film were shorter than the actual measurement (-.314), while the majority of the measurements made using the digital segmental measurement tool were longer than the actual measurement (.467). (Table 1) Discussion No significant differences between the two modalities and the gold standard were found. Measurements made from both conventional film and direct digital images were less than 1 mm different from direct measurements from the extracted teeth. This finding suggests the Shick Technologies CDR digital system may be suitable for use in estimating the preoperative working length in endodontic treatment. Use of this digital system offers the benefits of reduced patient exposure to ionizing radiation and rapid image production without the use of a darkroom. In addition, the digital images may be enhanced to highlight areas of interest. Difference in measurements from the two modalities were statistically significant, however, the difference was not considered clinically significant at less than 1 mm. Although the difference was small, one of the modalities (direct digital) overestimated, while the other (E-speed film) underestimated working length. One possible explanation may have been the lack of a reference point on the occlusal surface of the teeth from which to make the measurements. This study found the measurements made using the segmental measurement tool from the Shick Technologies CDR digital system were comparable to those made using conventional film radiography. Additional studies are warranted to further evaluate the direct digital segmental measurement tool. Table 1. Comparison of direct measurements with measurements made using DDR and conventional film. Mean Working Lengths Differences from Direct Measurement Direct Measurement 19.14 mm N/A E-speed Film 18.83 mm -0.31 mm Digital 19.61 mm +0.46 mm 3

References 1. Ingle JI. Endodontic instruments and instrumentation. Dent. Clin. North Am., pp. 805-22, November, 1957. 2. Bramante MC. A critical evaluation of some methods of determining tooth length. Oral Surg Oral Med Oral Pathol., pp463-73, March, 1974. 3. Stein TJ, Corcoran JF. Radiographic "working length" revisited. Oral Sur Oral Med Oral Pathol 1992;74: 796-800. 4

About the Authors 5