Agilent 6410 Triple Quadrupole LC/MS. Sensitivity, Reliability, Value

Similar documents
Agilent 6490 Triple Quadrupole LC/MS System with ifunnel Technology. Ultra sensitive quantitative performance

Using Software Tools to Improve the Detection of Impurities by LC/MS. Application Note. Christine Miller Agilent Technologies.

Agilent s LC/MS Portfolio and Applications Examples

Quantitative Analysis of Opiates in Urine Using RRHT LC/MS/MS. Application. Authors. Introduction. Abstract. Forensics

Vitamin D3 and related compounds by ESI and APCI

Join the mass movement towards mass spectrometry

Breaking the Sensitivity Barrier in Triple Quad LC/MS Performance

More structural information with MS n

LC/MS/MS SOLUTIONS FOR LIPIDOMICS. Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS

The New 6495 Triple Quadrupole LC/MS

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

Identification of Steroids in Water by Ion Trap LC/MS/MS Application

Rapid, Simple Impurity Characterization with the Xevo TQ Mass Spectrometer

LC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell 120 EC C18 Column

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

Quantitation of Protein Phosphorylation Using Multiple Reaction Monitoring

LC/MS/MS of Trichothecenes and Zearalenone in Wheat Using Different Sample Prep Methods

Introduction to LC/MS/MS

MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager

Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 1290 Infinity II/6230B LC/TOF system

Reduced Ion Suppression and Improved LC/MS Sensitivity with Agilent Bond Elut Plexa

Quantification of lovastatin in human plasma by LC/ESI/MS/MS using the Agilent 6410 Triple Quadrupole LC/MS system

A Definitive Lipidomics Workflow for Human Plasma Utilizing Off-line Enrichment and Class Specific Separation of Phospholipids

Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ

Liquid Chromatograph Mass Spectrometer LCMS-8050 C146-E232A

Detection, Confirmation, and Quantification of Chloramphenicol in Honey, Shrimp and Chicken Using the Agilent 6410 LC/MS Triple Quadrupole

Toxicology Screening of Whole Blood Extracts Using GC/Triple Quadrupole/MS

Liquid Chromatograph Mass Spectrometer LCMS-8040 C146-E188E

application Natural Food Colorants Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

Ultra Performance Liquid Chromatography Coupled to Orthogonal Quadrupole TOF MS(MS) for Metabolite Identification

Impurity Identification using a Quadrupole - Time of Flight Mass Spectrometer QTOF

Performance Characteristics of the Agilent High Matrix Sample Introduction (HMI) Accessory for the 7500 Series ICP-MS. Product Overview.

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions

AbsoluteIDQ p180 Kit. Targeted Metabolite Identifi cation and Quantifi cation

Mass Spectrometry Made Simple for Clinical Diagnostic Labs

Comprehensive Forensic Toxicology Screening in Serum using On-Line SPE LC-MS/MS

Application Note. Abstract. Authors. Pharmaceutical

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

Modified QuEChERS for HILIC LC/MS/MS Analysis of Nicotine and Its Metabolites in Fish

Highly Repeatable Ultra Low Detection of Estradiol Using Triple Quadrupole GC/MS in NCI Mode

Qualitative and quantitative determination of cannabinoid profiles and potency in CBD hemp oil using LC/UV and Mass Selective Detection

Author. Introduction. Abstract

Key Advantages of Comprehensive Cannabis Analysis

Metabolomic fingerprinting of serum samples by direct infusion mass spectrometry

DETERMINATION OF CANNABINOIDS, THC AND THC-COOH, IN ORAL FLUID USING AN AGILENT 6490 TRIPLE QUADRUPOLE LC/MS

Rapid Lipid Profiling of Serum by Reverse Phase UPLC-Tandem Quadrupole MS

Rapid and Robust Detection of THC and Its Metabolites in Blood

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

Fully Automated Online Sample Preparation AND Quantification of Amiodarone from Whole Blood using CLAM-LC-MS/MS

Single Quadrupole Compact Mass Spectrometer for Liquid Sample

Confident, lower-pressure analysis of carbohydrates, alcohols, and organic acids. Agilent Hi-Plex Ligand-Exchange HPLC Columns

LECTURE 3. Ionization Techniques for Mass Spectrometry

Polymer Additive Analysis by EI and APCI

Made For Routine Food, Environment, and Forensic Testing

Quantitative Analysis of Amphetamine-Type Drugs by Extractive Benzoylation and LC/MS/MS. Application. Introduction. Authors. Abstract.

INTRODUCTION CH 3 CH CH 3 3. C 37 H 48 N 6 O 5 S 2, molecular weight Figure 1. The Xevo QTof MS System.

Profiling of Endogenous Metabolites Using Time-of-Flight LC/MS with Ion Pair Reverse Phase Chromatography

Analysis of Acrylamide in French Fries using Agilent Bond Elut QuEChERS AOAC kit and LC/MS/MS

Extended Mass Range Triple Quadrupole for Routine Analysis of High Mass-to-charge Peptide Ions

High Resolution Glycopeptide Mapping of EPO Using an Agilent AdvanceBio Peptide Mapping Column

Determination of Amantadine Residues in Chicken by LCMS-8040

INTRODUCTION TO MALDI IMAGING

Considerations of the use of Triple Quadrupoles or Ion Traps in Quantitative Applications

Cannabinoid Quantitation Using an Agilent 6430 LC/MS/MS

Improving Selectivity in Quantitative Analysis Using MS 3 on a Hybrid Quadrupole-Linear Ion Trap Mass Spectrometer

Determination of Multi-Residue Tetracyclines and their Metabolites in Milk by High Performance Liquid Chromatography - Tandem Mass Spectrometry

A FORENSIC TOXICOLOGY METHOD FOR THE DETERMINATION OF DESOMORPHINE, HEROIN, METHADONE, BUPRENORPHINE AND METABOLITES IN URINE USING LC/MS QQQ

Determination of Aflatoxins in Food by LC/MS/MS. Application. Authors. Abstract. Experimental. Introduction. Food Safety

Comprehensive Two-Dimensional HPLC and Informative Data Processing for Pharmaceuticals and Lipids

Authors. Abstract. Introduction. Environmental

LC-MS/MS Solutions for Comprehensive Cannabis Analysis

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

Author. Introduction. Small Molecule Pharmaceuticals & Generics

Sample Concentration and Analysis of Human Hormones in Drinking Water

New Instruments and Services

Modernizing the Forensic Lab with LC-MS/MS Technology

Jose Castro-Perez, Henry Shion, Kate Yu, John Shockcor, Emma Marsden-Edwards, Jeff Goshawk Waters Corporation, Milford, MA, U.S. and Manchester, UK

Measuring Lipid Composition LC-MS/MS

California TOF/QTOF Users Meetings: MS Settings. Jim Lau, Agilent Technologies.

The Agilent MassHunter Software. One Software for all Agilent Mass Spec Systems

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

LCMS-8030 Application Report. Steroids: Testosterone, Progesterone, Estradiol, Ethinylestradiol

Simultaneous Analysis of Amino Acids and Acylcarnitines in Dried Blood Spots

Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices

Small Scale Preparative Isolation of Corticosteroid Degradation Products Using Mass-Based Fraction Collection Application

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis

Fat-Soluble Vitamins Analysis on an Agilent ZORBAX Eclipse PAH Polymeric C18 Bonded Column

Opiates, Opioids and Benzodiazepines, Amphetamines & Illicit Drug Forensic Analysis by LC/MS

Application Note. Author. Abstract. Introduction. Food Safety

Extraction of a Comprehensive Steroid Panel from Human Serum Using ISOLUTE. SLE+ Prior to LC/MS-MS Analysis

Analyzing Phenyl Ureas and Carbamates with HPLC/API-MS. Presented by Chen-Kai Meng, Ph.D. Applications Chemist

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry

High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine

Quadrupole and Ion Trap Mass Analysers and an introduction to Resolution

Detection of Cannabinoids in Oral Fluid with the Agilent 7010 GC-MS/MS System

Agilent 1260 Infinity Analytical SFC System

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis

Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations

Efficient Quantitative Analysis of THC and Metabolites in Human Plasma Using Agilent Captiva EMR Lipid and LC-MS/MS

Transcription:

Agilent 64 Triple Quadrupole LC/MS Sensitivity, Reliability, Value

Sensitivity, Reliability, Value Whether you quantitate drug metabolites, measure herbicide levels in food, or determine contaminant levels in ground water, the triple quadrupole mass spectrometer is unequaled for quantitating trace organic compounds in complex matrices. The Agilent 64 Triple Quadrupole LC/MS establishes a new standard for value in a triple quadrupole mass spectrometer. It delivers outstanding sensitivity, great ease of use, and legendary Agilent reliability all at a very attractive price. Performance and reliability for demanding quantitative analyses The 64 Triple Quad is built upon Agilent s proven expertise in quadrupole mass spectrometry. Paired with Agilent s industry-leading 2 Series LCs and ZORBAX LC columns, the 64 delivers sensitive, reproducible analyses of target compounds in complex matrices. Femtogram-level sensitivity Maximized ion generation and transmission across a broad mass range ensure low limits of detection and quantitation regardless of application. Fast, high-throughput MS/MS An innovative collision cell maintains sensitivity and avoids memory effects even at very short dwell times. Rugged, reliable performance Orthogonal nebulization and high drying capacity simplify operation, allow split-less operation at common flow rates, keep the ion optics cleaner, and reduce background. Tremendous versatility A broad selection of ion sources allows the 64 to address the widest range of applications. Simplified operation Automated tuning, parameter-less integration, method editor, curve-fit assistant, batch review, outlier flagging, and customizable reporting maximize convenience and throughput for the quantitation of large, multicompound batches. 25 µl/min m/z 69 --> of 3 MS/MS transitions Analysis of a reserpine dilution series in coffee shows femtogram-level sensitivity even in a complex matrix 2

Agilent 64 Triple Quadrupole LC/MS Low limits of quantitation regardless of application The Agilent 64 Triple Quadrupole LC/MS has been designed to maximize ion generation and ion transmission across a broad mass range, for low limits of detection and quantitation regardless of application. Nebulizing gas Ions Heated nitrogen drying gas Great sensitivity starts with superior ionization technology Agilent s LC/MS ion sources use our patented nebulization technology. Superior nebulization, orthogonal to the axis of the sampling capillary, reduces noise related to incomplete drying of solvent droplets. It also keeps the sampling capillary and ion optics cleaner, for reduced maintenance. The standard sources allow split-less operation at all common flow rates. Eluent spray Entrance to dielectric capillary Orthogonal nebulization and high drying capacity reduce droplet noise for better sensitivity, and also reduce maintenance requirements Collision cell innovations enhance sensitivity and speed The 64 Triple Quad features a highpressure, high-frequency hexapole collision cell that delivers rich MS/MS spectra with both sensitivity and speed. The collision cell uses linear axial acceleration to achieve very fast MS/MS, without cross-experiment memory effects (see page 4). It maintains excellent sensitivity even with five-millisecond dwell times (see page 4), so you can perform measurements over even the narrowest chromatographic peaks. Octopole ion guide Better ion transmission over a wider mass range Hyperbolic quadrupole Enhanced ion transmission and spectral resolution Hyperbolic quadrupole Enhanced ion transmission and spectral resolution Thin skimmer & short capillary-to-skimmer distance Reduced beam broadening Patented lenses Enhanced high-mass ion transmission and increased sensitivity High-pressure hexapole collision cell with linear acceleration Optimized MS/MS fragmentation without cross-experiment memory effects Off-axis, high-energy dynode detector High gain with rapid polarity switching, long life, and low noise Ion optics are optimized for ion transmission across a broad mass range www.agilent.com/chem/qqq 3

No cross-experiment memory effects 8 counts Abundance (counts) x 3.6.4.2.8.6.4.2 +EIC m/z 28. (MRM m/z 39. --> 28.) *.462 * 3.84 * 6.34 * 7.967 * 4.694.5.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5 8 8.5 9 Acquisition Time (min) 8 counts Abundance (counts) 7 6 5 4 3 2 +EIC m/z 28. (MRM m/z 4. --> 28.).5.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5 8 8.5 9 Acquisition Time (min) MS/MS analysis of 5 pg of alprazolam at 2 ms dwell time shows excellent RSD and no detectable cross-experiment memory effects (cross talk). Note that the top scale is 225 times the bottom scale. Excellent %RSD even at short dwell times x 3 +EIC m/z 28. (MRM m/z 39. --> m/z 28.); Alprazolam 2 pg on column Abundance 3 2 Dwell Time Area %RSD ms 486.6 2 ms 365.74 5 ms 322 2.25.5.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5 8 8.5 9 Time (min) Analysis of 2 pg of alprazolam on column shows only minor changes in peak area and percent RSD even at very short MS/MS dwell times. This makes the 64 ideal for fast chromatography and high throughput. 4

Agilent 64 Triple Quadrupole LC/MS Excellent linearity over a wide dynamic range Abundance x 5.4.2.8.6.4.2 +EIC m/z 28.9 (MRM m/z 39. --> m/z 28.9 m/z) Alprazolam to pg x 2.8.6.4.2.8.6.4.2 pg 5 pg 9.446 pg 2.74 23.985 6.58 2 ng ng 45.346 47.6 5 6 7 8 9 2 2 22 23 24 4.963 44.2 6.58 9.446 2.74 25.827.38629.626 32.97935.2737.459 39.75 5 ng 48.739 5. ng 52.32 54.395 5 2 25 3 35 4 45 5 55 Time (min) This alprazolam analysis in positive electrospray mode demonstrates excellent linearity over a wide dynamic range x 5 8 Abundance 7 6 5 4 3 2 Y = 77.2x + 593.4 R2 =.9974 2 3 4 5 6 7 8 9 Amount (pg) Versatility of multiple ionization choices For maximum flexibility in matching your 64 to your applications, Agilent offers a wide selection of ionization sources: Electrospray ionization (ESI) Atmospheric pressure chemical ionization (APCI) Atmospheric pressure photoionization (APPI) Multimode (ESI/APCI) HPLC-Chip Cube MS interface The multimode source is a breakthrough offering nearly universal ionization for LC/MS users who want greater versatility, throughput, and convenience. It can operate in, and automatically switch between, a variety of modes: ESI only APCI only Alternating ESI/APCI mode True simultaneous ESI and APCI with results as good as or better than dedicated, singlemode sources. The multimode source facilitates access for multiple users and long, unattended runs involving more than one ionization mode. Agilent multimode (ESI/APCI) source simplifies access and maximizes throughput while delivering superior performance www.agilent.com/chem/qqq 5

All new, sample- and compound-centric software The all-new Agilent MassHunter Workstation software makes your analyses easier. It includes separate programs for instrument control and data acquisition, qualitative data analysis, and quantitative data analysis. Each program is designed to simplify operation and maximize productivity. Faster, easier setup and acquisition Whether you are an expert or new to LC/MS, MassHunter Workstation software greatly simplifies operation of your LC/MS system. Tune automatically A proven, reliable autotune program maximizes performance and minimizes effort. Save time setting up analyses Import worklists directly from spread sheet programs such as Microsoft Excel. Operate from a single user interface A single interface for both LC and MS can be configured to display only the information you need. Better, easier quantitation All-new, sample- and compound-centric quantitation software ensures that you spend less time analyzing your data. Set up quantitation more easily Import information directly from the data acquisition method. Find the best curve fit faster A curve-fit assistant tests all fits and provides statistics on their quality. Better integration Automated, parameter-less integrator uses a novel algorithm, optimized for MRM data from a triple quad, to achieve superior integration with minimum user input. Dynamically linked results save time Calibration curves are automatically updated when you reintegrate a peak. Review an entire batch at once The batch-at-a-glance interface helps you review more samples more easily. Outlier values are automatically flagged Color coding focuses your attention where it is needed. MassHunter Workstation software for the 64 includes a range of calibration options, from manual tuning to the fully automated autotune program shown here that ensures maximum performance with minimum effort 6

Agilent 64 Triple Quadrupole LC/MS The curve-fit assistant automatically tests all possible fits and provides statistics on their quality, making it easy for you to select the best fit The "batch-at-a-glance" interface allows you to navigate the results on a compound- or sample-centric basis. Dynamic linking of compound results and color coding of outliers help you focus on problem data and significantly speed up results review. Shown here is quantitation of four drugs of abuse with ISTDs in oral fluid. www.agilent.com/chem/qqq 7

For more information Learn more: www.agilent.com/chem/qqq Buy online: www.agilent.com/chem/store The MassHunter Workstation software includes a wide array of standard report templates, and allows you to easily customize them in the well-known Microsoft Excel environment. You can also use Excel to preview printed reports. Flexible reporting With the MassHunter Workstation software, reporting is fast and flexible. Preconfigured templates simplify basic reports, or you can create custom reports in the familiar Microsoft Excel user interface. Processed results and system parameters are stored in XML, a standard data interchange format, so they can easily be imported into proprietary databases or informatics systems. Find an Agilent customer service center in your country: www.agilent.com/chem/contactus u.s. and canada -8-227-977 agilent_inquiries@agilent.com europe info_agilent@agilent.com asia pacific adinquiry_aplsca@agilent.com Research use only. Information, descriptions and specifications in this publication are subject to change without notice. Agilent Technologies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material. Microsoft is a U.S. registered trademark of Microsoft Corporation. Agilent Technologies, Inc. 26 Printed in the USA April, 26 5989-4894EN