GE Healthcare Life Sciences. Quality matters. Whatman TM filters for air monitoring

Similar documents
GE Healthcare Life Sciences. Quality matters. Whatman TM filters for air monitoring

P2-P3 P3-P4 P4-P5 P5-P6 P6-P7 P7 P8 P8-P9 P9-P11 P11-P13

All of our Radioiodine Cartridges

Contents. 01 Welded Syringe Filter Economy Syringe Filter Sterile Syringe Filter Membrane Filter 21

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP

CORESTA RECOMMENDED METHOD N 8

Residuals/Impurities. Are All Substances Above the Threshold Indicated: Nested Materials Method Basic Method

Heparin Sodium ヘパリンナトリウム

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certificate of Secondary Education

FILTERS (MEMBRANE) Sterile Cellulose Nitrate Membrane Filters, Gridded. Whatman. FilterCups Disposable Filter Funnels, Whatman

MONOGRAPHS (USP) Saccharin Sodium

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP

Cecilia Pretorius CSIR Centre for Mining Innovation (CMI) CSIR/CMI/HF/EXP/2010/0028/A

MONOGRAPHS (NF) Pharmacopeial Forum 616 HARMONIZATION Vol. 31(2) [Mar. Apr. 2005]

Norcross, GA TRANSPORTATION EMERGENCIES (24 Hrs.): CHEMTREC (800) GENERAL INFORMATION : (770)

Petrolatum. Stage 4, Revision 1. Petrolatum is a purified semi solid mixture of hydrocarbons obtained from petroleum.

GRIMM. European Approval PM10 & PM2.5. situation & legislation for. Aerosol Technik

Nondestructive Testing Procedure: Liquid Penetrant Testing

Restek PAL SPME Fibers cat.#

TALC: ASBESTOS ISSUES AND MANAGEMENT Asbestos has long been considered a known human carcinogen

Development, Fabrication and Study of Fullerene- Containing Carbon Material (FCC) for Immobilization of Iodine: Final report 2005

AIR PURIFICATION AND AROMATHERAPY SYSTEM

EASIMIP TM PATULIN Product Code: P250 / P250B

CHAPTER 5 CHARACTERIZATION OF ZINC OXIDE NANO- PARTICLES

CORESTA Recommended Method No. 84

The new generation of TipOne Pipette Tips

Based on the selected Content Inventory Threshold:

Nitrogen and Protein Determination in Meat Products by Accelerated Digestion with Hydrogen Peroxide and Sulfuric Acid

EASI-EXTRACT FOLIC ACID Product Code: P81 / P81B

Residuals/Impurities. Considered Partially Considered Not Considered. Explanation(s) provided. for Residuals/Impurities? Yes No

Nanopigments For Broad Spectrum Sun Protection. Patricia Aikens NAFTA Technical Services

Hazardous Substances

Residuals/Impurities. Are All Substances Above the Threshold Indicated: Nested Materials Method Basic Method

FERTILIZER. Safety Data Sheet. OSHA Haz Com Standard 29 CFR V Kraft Rd Lakeland, FL

Global Standards Engineering Policy & Procedure

SPE Cartridges. All Finneran Products Are Certified. Conditioning Sample application Wash Elution

Application Note No. 119/2013 Determination of bisphenol A in preserved food SpeedExtractor E-916: Determination of bisphenol A in preserved food

Based on the selected Content Inventory Threshold:

Membrane Chip Interface and Accessories

Purves Environmental, Inc. Since 1993

Agilent Captiva Sample Preparation Filtration Portfolio GAUGE THE DIFFERENCE FILTRATION CAN MAKE

STARCHES FOR COSMETIC INDUSTRIES CORN PO4 PH B AND RICE NS

A Primer on Acute Inhalation Toxicity Testing

Caleva tablet dissolution baths normally use cannula style filters with a large range of porosities. 100 Pack 1000 Case. 100 Pack 1000 Case

Chapter 7 Notes. Section 1

SAFETY DATA SHEET (SDS): COASTAL BRAND SHELL

1 PRODUCT AND COMPANY IDENTIFICATION

GB Translated English of Chinese Standard: GB NATIONAL STANDARD

Material Safety Data Sheet Alkaline Iodide Azide Solution I. Section 1 - Chemical Product and Company Identification

Risk Assessment Issues: Asbestos p. 100 Review of Epidemiological Evidence for Health Effects in Workers Exposed to MMMFs p. 103

Thermo Scientific ART Pipette Tips. superior tips. for any application, any pipette

EASI-EXTRACT BIOTIN Product Code: P82 / P82B

BROEN UNIFLEX FITTINGS FOR NON-BURNING 2.0 GASES / VACUUM

Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 82 nd meeting 2016.

Pectins. Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 82 nd meeting 2016

Analytical Method for 2, 4, 5-T (Targeted to Agricultural, Animal and Fishery Products)

FAO SPECIFICATIONS FOR PLANT PROTECTION PRODUCTS

Implementation Guide for the DoseControl Dosimetry System

ACUMER 4161 Phosphinopolycarboxylic Acid Scale Inhibitor and Dispersant

Based on the selected Content Inventory Threshold:

DuPont Nafion PFSA Membranes NRE-211 and NRE-212 Perfluorosulfonic acid polymer. Membranes. Product Information. Description. Coversheet.

Canister FR-15-CBRN. User Instructions. Important: Keep these User Instructions for reference

Solution range. Superior accuracy in surface interaction analysis

CELLULOSE, MICROCRYSTALLINE. Cellulosum microcristallinum. Cellulose, microcrystalline EUROPEAN PHARMACOPOEIA 7.0

THE BENCHMARK IN CAR AIR PURIFICATION TECHNOLOGY SHEPROS. Safety, Health & Environmental Product Solutions

Engineering the Growth of TiO 2 Nanotube Arrays on Flexible Carbon Fibre Sheets

HYDROXYPROPYLCELLULOSE, LOW SUBSTITUTED Stage 4, Revision 1 CP: USP BRIEFING NOTE

LECTURE 10. PACKAGING TECHNOLOGY

Material Safety Data Sheet Buffer Solution ph 9.0. Section 1 - Chemical Product and Company Identification

JUST. in Case. Acids in Safebreak bottles

CORESTA RECOMMENDED METHOD NÄ 9

Pure animal nutrition

Microfiltration Membranes

Safety Data Sheet MasterEmaco ADH 1490 PART B also CONCRESIVE 1490 PTB Revision date : 2012/01/27 Page: 1/7

Autotitrator. Technical Information and Specifications. mpt-2. detailed specification sheets from

PUTTING ON PAPER. Dow Paper Coatings

Membranes. Chapter 5. Membrane Structure

MATERIAL SAFETY DATA SHEET

CRYSTALLINE SILICA EMPLOYEE TRAINING

EUDRAGIT L 100 and EUDRAGIT S 100

8.05 days 138 days 7.60 days 0.22 mr/h at 1.0 meter per millicurie 124,068 curies/gram 2 mm = 0.20 cm = 0.08 in 165 cm = 65.0 in = 5.

1 out of 8. Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 86th Meeting 2018 ERYTHROSINE

DURAMAX 50 RV ANTIFREEZE MSDSP380

Multifunctional Cellulosic Scaffolds from Modified Cellulose Nanocrystals. Eldho Abraham and Oded Shoseyov Hebrew University of Jerusalem, Israel

Material Safety Data Sheet Buffer Solution for Water Hardness, ASTM. Section 1 - Chemical Product and Company Identification

EMERGENCY PHONE: or (651) (24 hours)

Product Guide for LudgerSep TM ur2 UHPLC Column for DMB Sialic Acid Analysis

Prevention of respiratory diseases and occupational diseases

OG TAL ODUCT CA PR e e HEALTH

Material Safety Data Sheet

ProAir Clear 2 Pack FOR PROFESSIONAL USE ONLY

KEY RESIN #510LV EPOXY BINDER

Based on the selected Content Inventory Threshold:

LIQUID PENETRANT EXAMINATION PROCEDURE

247 CMR BOARD OF REGISTRATION IN PHARMACY

Plastic Storage Bottles. Product Selection Guide

Based on the selected Content Inventory Threshold:

Based on the selected Content Inventory Threshold:

David M. Shelow, Restek Corporation, 110 Benner Circle, Bellefonte, PA 16823

Transcription:

GE Healthcare Life Sciences Quality matters Whatman TM filters for air monitoring

Quality matters Why does quality matter? Particulate testing Examples include PM 10 & PM 2.5 particulate monitoring. Quality matters, because you need to focus on delivering accurate results on the quality of the air sample, without worrying about the quality of the consumables you use on a daily basis. This is why GE Healthcare Life Sciences is committed to supporting you with high-quality Whatman filters that are: Manufactured in ISO certified facilities Reproducible, supporting consistent performance Qualified for specific air monitoring applications (e.g., PM 2.5 membrane for PM 2.5 determination of suspended particulates in air) This brochure highlights the filtration solutions offered under the Whatman brand for the applications shown to the right. Chemical analysis Examples include analysis for ozone, sulfur dioxide and heavy metals. Asbestos control Examples include asbestos monitoring by optical analysis. 2

What are you testing? Under which circumstances? We recommend Particulate monitoring methods Automated sampling Page 4 Glass Microfiber Reels Manual sampling Aggressive Environment (high temp and acidic ) Page 5 Quartz fiber filter such as QM-A Quartz fiber thimbles Manual sampling Normal environment Pages 4 and 6 Glass fiber filters such as GF/A and EPM 2000 Membrane filters such as PTFE Glass fiber thimbles Radioactivity Page 4 Grade 72 SAS cards-static Air Sampling * PAS cards-personal Air Sampling * Glass fiber filters such as GF/A Chemical Analysis Heavy metals Pages 4 and 5 Quartz fiber filters EPM 2000 glass fiber filters Other chemicals (such as Ozone, Volatile Organic Carbons, SO 2, NO 2, CO, Benzoate) Pages 4, 5, 6 Glass fiber filters Quartz fiber filters Cellulose filters* PTFE membranes Asbestos Analysis Analysis by microscopy Page 7 Polycarbonate membranes such as Cyclopore TM and Nuclepore TM Mixed cellulose ester such as ME25/21 and MembraClear Air retention efficiency: GF/A, EPM 2000, and QM-A have an air retention efficiency of greater than or equal to 99.95% of 0.3 µm size particulates. A Certificate of analysis is available for each batch (upon request; Fig 1) Fig 1. Example of certificate of analysis featuring the air retention efficiency range This list of applications is not exhaustive. Please contact your Fisher Scientific representative for more information. *please contact your Fisher Scientific representative for information on SAS, PAS cards and cellulose filter papers. 3

Glass fiber filters and thimbles Two of the most significant fractions of suspended particulate matter are the respirable fraction (< 2.5 μm) and the inhalable fraction (< 10 μm). Two important tests performed in air monitoring of particulate matter, PM 2.5 and PM 10, are concerned with these two fractions. Whatman glass fiber filters are recommended for gravimetric determination of airborne particulates, such as PM 10, stack sampling, and absorption methods of air pollution monitoring. Products Binder or binder free Material Features and benefits GF/A Binder free Glass fiber Fine particle retention High flow rate Good loading capacity EPM 2000 Binder free Glass fiber Used in high-volume PM-10 air sampling equipment Detailed chemical analysis of trace pollutants GF10 Binder Glass fiber Extreme mechanical stability Used as a weighing aid in infrared weighing Used up to 180 C Grade 72 N/A Glass fiber/ cellulose Used to absorb radioactive iodine in air pollution monitoring and in nuclear installations Glass fiber thimbles Binder and binder free Glass fiber Used at temperatures up to 500 C Glass fiber filters can be customized in a reel format for use in automated air sampling systems Fig 2. EPM 2000 Glass fiber filters Fig 3. Glass fiber reel for automated samplers 4 Ordering information -- Glass fiber filters, circles and sheets Grade Code no. Code no. Code no. Code no. Code no. Code no. Quantity Dimensions 25 mm 37 mm 47 mm 50 mm 90 mm 8 10 inches (sheet) GF/A 0987412A 0987412B 0987414A 09874601 0987416B 09927858 100/pack EPM 2000 - - 0987469 - - 0987467 100/pack GF 10 - - 09924281 09924278 09924279** 200/pack Grade 72 - - 09874603 - - - 100/pack Ordering information -- Glass fiber filters, reels Grade Code no. Code no. Code no. Quantity Dimensions 70 mm 50 m 35 mm 30 m 50 mm 100 m GF 10 09927954 09927955 09924283 1/pack Ordering information -- Glass fiber thimbles Binder Code no. Code no. Code no. Code no. Quantity Dimensions* 22 80 mm 25 100 mm 33 94 mm 10 38 mm Inorganic binder 09924286 09924289 09924292 09874621 25/pack Other dimensions available for thimbles (with or without binder). Please contact your Fisher Scientific representative. *internal diameter external length **100/pack

Quartz fiber filters and thimbles GE Healthcare offers two types of quartz filters QM-A and QM-H. The low level of alkaline earth metals in these filters virtually eliminates artefact products of sulfates and nitrates (from SO 2 and NO 2, respectively). QM-H is a pure quartz fiber filter with low heavy metal content. We also offer quartz fiber thimbles. More information is available on the tables below. Features and benefits of quartz fiber filters: High-purity quartz (SiO 2 ) microfiber filters are mainly used in air pollution monitoring. Used for air sampling in acidic gases, stacks, flues, and aerosols, particularly at high temperatures. Applicable for particulate monitoring and heavy metal analysis. QM-A quartz fiber filters QM-H quartz fiber filters Quartz fiber thimbles High-purity quartz microfiber filters Used for air sampling, particularly at high temperatures up to 500 C 100% pure quartz Can be used up to 900 C Low heavy metal content Made from high-purity quartz microfiber Able to withstand high temperatures (up to 1000 C) Suitable for both solvent extraction and air sampling applications Fig 4. QM-A quartz fiber filters Ordering information -- Quartz fiber filters and thimbles Product name Dimensions Code no. Quantity QM-A quartz fiber filter 25 mm diam. 09874605 100/pack 37 mm diam. 0987488 100/pack 47 mm diam. 0987489 100/pack 50 mm diam. 09874606 100/pack 90 mm diam. 09874607 100/pack 8 10 inches (sheet) 09873P 100/pack Quartz fiber thimbles 25 90 mm* 09874622 10/pack *internal diameter external length 5

PTFE and mixed cellulose ester membrane filters PTFE membranes Whatman TE and PM 2.5 membrane filters from GE Healthcare are made from PTFE material. These membrane filters are chemically resistant and possess low chemical background interference (e.g., metals), allowing the user to carry out sensitive determinations. PM 2.5 filters are used for the measurement of fine particulate matter in the atmosphere. Whatman TE membranes are general purpose PTFE membrane filters that have multiple applications in environmental analysis. Use Whatman PM 2.5 membranes for the EPA PM 2.5 reference method (under the requirements of 40 CFR part 50 Appendix L) Fig 5. PM 2.5 membranes for use in particulate matter testing Product name TE type membranes PM 2.5 membranes Features and benefits Suitable for filtration of gases and liquids Resistant to most acids, alkalis, and solvents such as sodium hydroxide and hexane: Laminated onto a nonwoven polypropylene support material Increased durability for aggressive testing environments Hydrophobic characteristics prevent passage of aqueous aerosols (e.g., during venting applications) Used for PM 2.5 ambient air monitoring Conforms to EPA PM 2.5 reference method under the requirements of 40 CFR part 50 Appendix L Manufactured under clean room conditions Does not contain glues or adhesives Sequentially numbered for easy traceability of the filter Chemically resistant polypropylene support ring, which eliminates curling, and makes the filter robot-friendly Retains a minimum of 99.7% of 0.3 µm size particulates 6 Mixed cellulose ester membranes Mixed cellulose membranes from GE Healthcare are designed to meet your environmental air monitoring requirements. These membranes are typically used in applications for the determination of metals in airborne particulates. Ordering information -- Membrane filters Membrane type Pore size Code no. Code no. Code no. Code no. Code no. Quantity Diameter 25 mm 37 mm 46.2 mm 47 mm 50 mm PM 2.5 PTFE membrane 2 µm - - 057175 - - 50/pack TE type PTFE membrane 0.2 µm 09927606 - - 09874619 09874620 50/pack 0.45 µm 09927602 - - 9301099 09874618 50 /pack 1 µm 09874614 - - 09874615 09874616 50/pack 5 µm - 09874609-09874610 09874611 50/pack Mixed cellulose ester membrane 0.2 µm 09927775 - - 09927205 09927715 100/pack 0.45 µm 09927178 - - 09927611 09927192 100/pack 0.8 µm 09927186 09927260-09927189 09927256 100/pack 3 µm 09927181 - - 09927184 09927751 100/pack

Membranes for asbestos sampling and analysis Asbestos analysis is commonly undertaken by a number of microscopy techniques such as Scanning Electron Microscopy (SEM), Transmission Electron Microscopy (TEM), and Phase Contrast Microscopy (PCM). These methods usually involve sampling and/or observation, both of which involve the use of membrane filters such as polycarbonate or mixed cellulose ester membranes. Fig 6. Asbestos fibers on a Cyclopore membrane Product name Membrane material Features and benefits ME type (e.g., ME 25/21) MembraClear Nuclepore and Cyclopore Mixed ester cellulose Mixed ester cellulose Polycarbonate Typically used for Transmission Electron Microscopy (TEM) Available with or without grid Full range of pore sizes High air flow rates Designed for use with Hot Block Method (PCM technique) White with black grid for high contrast 0.8 μm pore size Becomes transparent with acetone vapor treatment; absence of crystalline artifacts aids in visualization Controlled pore size distribution Smooth flat membrane: particles are retained on surface and easily visible during optical analysis Nuclepore membranes available in two versions: gold coated or uncoated Ordering information -- Membrane filters for asbestos sampling and analysis Membrane Pore size Code no. Code no. Code no. Quantity Diameter 25 mm 37 mm 47 mm Nuclepore polycarbonate membrane 0.2 µm 0930061-0930069 100/pack 0.4 µm 0930062-0930071 100/pack 0.4 µm gold coated 09874624 - - 50/pack 0.8 µm 0930063 K08CP03700 0930072 100/pack Cyclopore polycarbonate membrane 0.2 µm 099303B - 099305B 100/pack 0.4 µm 099303C - 099305C 100/pack 1.0 µm - - 099305F 100/pack ME25/21 cellulose mixed ester membrane 0.45 µm - - 09874623 100/pack 7

GE, imagination at work, and GE monogram are trademarks of General Electric Company. Cyclopore, Nuclepore, and Whatman are trademarks of GE Healthcare companies. 2013 General Electric Company All rights reserved. First published Oct. 2013 BN09251311 10/2013