Rapid-VIDITEST Shigella dysenteriae

Similar documents
Rapid-VIDITEST. Helicobacter pylori. One step Helicobacter pylori Blister test. Instruction manual

Rapid-VIDITEST FOB Blister

Rapid-VIDITEST C. difficile Ag (GDH) Card/Blister

Rapid-VIDITEST Enterovirus

Rapid-VIDITEST. Rota-Adeno Blister. One Step Rotavirus and Adenovirus Antigen Blister test. Instruction manual

Rapid-VIDITEST. Rota-Adeno. One Step Rotavirus and Adenovirus Antigen Blister test. Instruction manual

Rapid-VIDITEST. Influenza A+B

Rapid-VIDITEST Calprotectin

Rapid-VIDITEST. Astrovirus Card

Rapid-VIDITEST Swine Flu

Rapid-VIDITEST. Influenza A

Rapid-VIDITEST. Strep A Blister. One step Strep A Blister for the detection of Group A Streptococcal antigen from throat swabs or culture.

Rapid-VIDITEST. Strep A Card. One step Strep A Card for the detection of Group A Streptococcal antigen from throat swabs or culture.

Rapid-VIDITEST. FOB+Tf. One step Fecal Occult Blood Card Test. Instruction manual

Rapid-VIDITEST. Calprotectin-Lactoferrin

Human Influenza A (Swine Flu) Rapid test

CDIA TM Rubella IgG/IgM Rapid Test Kit

Rotavirus Test Kit. Instructions For Use. Format: Cassette Specimen: Fecal Extract Catalog Number: VEL-001-ROTA

Hepatitis C Virus (HCV) Antibody Test

Helicobacter pylori Antigen Test

Fecal H. pylori Antigen Rapid Test (Strip)

Treponema Pallidum (TP) Antibody Test

Chlamydia trachomatis (CHLa)Test Kit

Strep-a-Test Twister Test

Dengue IgG/IgM/NS1 Combo Rapid Test Device

TB LAM Ag Lateral Flow Assay Standard Operating Procedure

Malaria Pf/pan antigen Rapid Test

Chlamydia Rapid Screen Test (RAP-2858) RUO in the USA. Revised 28 Jul 2006

CrAg Lateral Flow Assay Standard Operating Procedure

HAV IgM Rapid Test(Cassette)

USO PROFESSIONALE PROFESSIONAL USE

WHO Prequalification of Diagnostics Programme PUBLIC REPORT

A rapid test for the qualitative detection of Malaria pf and pv antigen in human blood sample

MALARIA P. FALCIPARUM / P. VIVAX

See external label. 2 C-30 C for test card and Sample tube Cat.# OneStep Rotavirus Antigen RapiCard InstaTest.

Procine sphingomyelin ELISA Kit

QUICK REFERENCE INSTRUCTIONS. THYROCHEK TSH Cassette

IV2-113E Use by. Invitron Glargine ELISA Kit REF LOT IVD. Definitions. English. For in-vitro diagnostic use. Instructions for use.

ELISA-VIDITEST anti-mycoplasma pneumoniae IgM

ELISA-VIDITEST anti-mycoplasma pneumoniae IgG assay Lot:

WHO Prequalification of In Vitro Diagnostics PUBLIC REPORT. Product: OraQuick HIV 1/2 Rapid Antibody Test WHO reference number: PQDx

IBD EZ VUE I. PRINCIPLE

HBeAg and HBeAg Ab ELISA Kit

WHO Prequalification of In Vitro Diagnostics PUBLIC REPORT. Product: OraQuick HIV 1/2 Rapid Antibody Test WHO reference number: PQDx

SAMPLE PROCEDURE , 07/11

25 OH Vitamin D Rapid Test

Infectious Mononucleosis IM Cassette Test RAPU04A830

ANTIBODY SCREENING by Uni-Gold Recombigen HIV

PROCEDURE. Sekisui Diagnostics OSOM ifob Rapid Test. Title: Procedure #: Institution: Prepared by: Date: Title: Accepted by: Date adopted: Title:

ENG MYCO WELL D- ONE REV. 1.UN 29/09/2016 REF. MS01283 REF. MS01321 (COMPLETE KIT)

HAV IgG/IgM Rapid Test

ELISA-VIDITEST anti-tbev IgM ODZ-194

Cotinine (Mouse/Rat) ELISA Kit

Malaria (Pan-LDH) W/B

H. pylori IgM CLIA kit

Human HBcAb IgM ELISA kit

25 OH Vitamin D Rapid test

H E A L T H & R E S E A R C H. Innovating the future

RIDA QUICK Rotavirus. Article no: N0902

ELISA-VIDITEST anti-chlamydia trachomatis IgA

Instructions for use. TSH rat ELISA. Please use only the valid version of the Instructions for Use provided with the kit AR E-8600

H. pylori Stool Rapid Test (Cassette)

Insulin (Porcine/Canine) ELISA

DETERMINE SPECIMEN REQUIREMENTS HIV-1/2 Ag/Ab Combo TESTING PROCEDURE

Rubella Latex Agglutination Test

See external label 2 C-8 C 96 tests CHEMILUMINESCENCE. CMV IgG. Cat # Step (20-25 C Room temp.) Volume

Helicobacter pylori IgA ELISA Kit

H.Pylori IgG

H.Pylori IgG Cat # 1503Z

See external label 96 tests HSV 2 IgA. Cat #

H. pylori IgM. Cat # H. pylori IgM ELISA. ELISA: Enzyme Linked Immunosorbent Assay. ELISA - Indirect; Antigen Coated Plate

Fastect II Drug Screen Dipstick Test Training and Certification Program

CLIA Complexity: Waived

ELISA-VIDITEST anti-chlamydia trachomatis IgM

H.pylori IgA Cat #

IVD Revised 22 July, 2008

Mouse C-Peptide ELISA Kit

See external label 2 C-8 C 96 tests Chemiluminescence. CMV IgM. Cat # Diluted samples, controls & calibrator 100 µl 30 minutes

Mouse/Rat THYROXINE (T4) ELISA Catalog No (96 Tests)

Human HIV (1+2) antigen&antibody ELISA Kit

Serum Amyloid A ELISA

ODZ-345. Instruction manual

CHEMILUMINESCENCE ENZYME IMMUNOASSAY (CLIA) Toxoplasma IgG. Cat # (20-25 C Room temp.) Volume

ONE-STEP WHOLE BLOOD H.PYLORI TEST. Product Code: 24529

Campylobacter Antigen ELISA Kit

25(OH) Vitamin D ELISA (BD-220BA), 192 Tests

Mycoplasma pneumoniae IgG ELISA Kit

Thyroid Stimulating Hormone (TSH) ELISA Catalog No. GWB , legacy id (96 Tests)

Human Cytomegalovirus IgM ELISA Kit

Summary of Significant Changes at this Revision. Items Required. Printed copies are uncontrolled unless there is an allocated Copy Number on page 1

H.Pylori IgM Cat # 1504Z

INSTANT-VIEW H. pylori Rapid Test CLIA WAIVED Test for Whole Blood QUALITATIVE IN-VITRO DIAGNOSTIC TEST FOR EXTERNAL USE ONLY

ELISA-VIDITEST anti-chlamydia trachomatis IgA

DIAGNOSTIC AUTOMATION, INC.

Triiodothyronine (T3) ELISA

See external label 2 C-8 C Σ=96 tests Cat # 1505Z. MICROWELL ELISA H.Pylori IgA Cat # 1505Z

Herpes Simplex Virus 2 IgG HSV 2 IgG

NEGATIVE POSITIVE. Rev , 06/11. 5 min. Mono Test. For fi ngertip. blood: 1 DROP 1 DROP For serum, whole blood. plasma or. samples.

HIV-1 p24 ELISA Kit. Catalog Number KA assays Version: 06. Intended for research use only.

Transcription:

Rapid-VIDITEST Shigella dysenteriae One step Shigella dysenteriae test for the qualitative detection of Shigella dysenteriae in faeces. Instruction manual Producer: VIDIA spol. s r.o., Nad Safinou II 365, Vestec, 252 42 Jesenice, Czech Republic, Tel.: +420 261 090 565, www.vidia.cz INTENDED USE: The Rapid-VIDITEST Shigella dysenteriae Card/Blister is a one step coloured chromatographic immunoassay for the qualitative detection of Shigella dysenteriae type 1 in stool samples to detect a possible shigellosis (bacillary dysentery) infection in humans. INTRODUCTION: The four species of the genus Shigella; S. dysenteriae, S. flexneri, S. boydii and S. sonnei cause a wide spectrum of illness from watery diarrhoea to fulminant dysentery. The low infectious inoculum, (as few as 10 organisms) render Shigella highly contagious. Shigellosis therefore occurs as an endemic disease in populations characterized by overcrowding, poor housing, poor sanitation and inadequate water supply. The predominant serogroups of Shigella occurring in a region also appears to be related to the socioeconomic development; and evidence also indicates that the severity of shigellosis is related to the infecting serogroup. For example, S dysenteriae type 1, also known as Shiga bacillus, has been recognized as the major cause of epidemic dysentery for nearly 100 years. Pandemics of Shiga dysentery have spread across Central America, Bangladesh, South Asia and Central and East Africa. Rapid-VIDITEST Shigella dysenteriae provides a rapid detection of Shigella dysenteriae directly from the stool samples. PRINCIPLE: The Rapid-VIDITEST Shigella dysenteriae Card/Blister is a qualitative immunochromatographic assay for the determination of Shigella dysenteriae type 1(in stool samples. The membrane is pre-coated with antibodies, on the test band region, to recognize this antigen. During testing, the sample is allowed to react with the coloured conjugate (anti-s. dysenteriae antibodies-red microspheres) which was pre-dried on the test. The mixture then moves upward on the membrane by capillary action. As the sample flows through the test membrane, the coloured particles migrate. In the case of a positive result the specific antibodies present on the membrane will capture the coloured conjugate (result region). The mixture continues to move across the membrane to the immobilized antibody placed in the 1

control band region, a GREEN coloured band always appears. The presence of this GREEN band serves as 1) verification that sufficient volume is added, 2) that proper flow is obtained and 3) as an internal control for the reagents. MATERALS PROVIDED: - Rapid-VIDITEST Shigella dysenteriae Card/Blister tests - Instructions for use - Specimen collection vial with buffer MATERIALS REQUIRED BUT NO PROVIDED: - Specimen collection container - Disposable gloves - Timer SPECIMEN COLLECTION AND PREPARATION: Stool samples should be collected in clean containers and the assay should be done right after collection. The samples can be stored in the refrigerator (2-4 ºC) for 1-2 days prior to testing. For longer storage, the specimen must be kept frozen at 20ºC. In this case, the sample will be totally thawed, and brought to room temperature before testing. Ensure only the amount needed is thawed because of freezing and defrosting cycles are not recommended. Homogenise stool sample as thoroughly as possible prior to preparation. PROCEDURES: To process the collected stool samples: Use a separate vial for each sample. Unscrew the cap of the vial (1) and introduce the stick in different parts of the faecal specimen to pick up the sample (approx. 150mg) (2) (introduce the stick in 3 different parts of the sample) and put into the vial with buffer. Shake the vial in order to assure good sample dispersion (3). For liquid stool samples, aspirate the faecal specimen with a dropper and add 150µL into the vial with buffer. Close the tube with the diluent and stool sample. Shake the tube in order to assure good sample dispersion. 2

Test Procedure: Allow the tests, stool samples and buffer to reach to room temperature (15-30ºC/59-86ºF) prior to testing. Do not open the pouch until ready to perform the assay. Test Procedure for Card test 1. Remove the Rapid-VIDITEST Shigella dysenteriae Card from its sealed pouch and use it as soon as possible. 2. Shake the specimen collection vial to assure a good sample dispersion. Break off the cap of the vial (4). 3. Use a separate device for each sample. Dispense exactly 4 drops into the specimen well (S) (5). Start the timer. 4. Read the result at 10 minutes after dispensing the sample. Test Procedure for Blister test Procedure A: Using the blister test single pack as a card test: 1. Cut the blister to obtain a test single pack, hold the non sealed side and open it peeling off the upper foil. Don t remove the test from the blister cavity and use it as soon as possible. 2. Shake the specimen collection vial to assure good sample dispersion. Place the blister test single pack horizontally and identify it. 3. Dispense 5 drops of sample+buffer on the white end of the test (4). Start the timer. Read the result at 10 minutes after dispensing the sample. Procedure B: By immersion: 1. Cut the blister to obtain a test single pack, hold the non sealed side and open it peeling off the upper foil. 2. Shake the specimen collection vial to assure good sample dispersion. Dispense 5-10 drops of sample+buffer in an identified vial and leave the test strip to stand vertically in the vial, taking care of not surpassing the limit of immersion indicated with the arrows (5). Start the timer. Read the result at 10 minutes. 3

INTERPRETATION OF RESULTS: CARD BLISTER POSITIVE NEGATIVE INVALID POSITIVE: Two lines appears across the central window in the result line region, a red test line marked with the letter T and in the control line region, a green control line marked with the letter C. NEGATIVE: Only one green band appears across the control line region marked with the letter C. 4

INVALID: A total absence of the green control coloured band regardless the appearance or not of the red test line. Note: Insufficient specimen volume, incorrect procedural techniques or deterioration of the reagents are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue using the test kit and contact you local distributor. NOTES ON THE INTERPRETATION OF RESULTS: The intensity of the red coloured band in the result line region (T) will vary depending on the concentration of antigens in the specimen. However, neither the quantitative value, nor the rate of increase in antigens can be determined by this qualitative test. QUALITY CONTROL: Internal procedural controls are included in the test: A green line appearing in the control line region (C). It confirms sufficient specimen volume and correct procedural technique. LIMITATIONS: 1. The test must be carried out within 2 hours of opening the sealed bag. 2. An excess of sample could cause wrong results (brown bands appear). Dilute the sample with the buffer and repeat the test. 3. Some stood samples can decrease the intensity of the control green line. 4. Positive samples, frozen and thawed in several times (more than 3 times), could cause wrong results. 5. A negative result is not meaningful because it is possible the Shigella dysenteriae content in the stool sample to be too small. A Shigella dysenteriae determination should be carried out on a sample from a enrichment culture. 6. This test provides a presumptive diagnosis of shigellosis. A confirmed infection diagnosis should only be made by a physician after all clinical and laboratory findings have been evaluated must be based in the correlation of the results with further clinical observations. EXPECTED VALUES: Bacillary dysentery caused by Shigella dysenteriae type 1 is a major public health problem in many developing countries. There are four known species of Shigella which are pathogenic, and infection with S. dysenteriae type 1 usually progresses to the most severe form of dysentery with life-threatening complications. The most common underlying cause of death in fatal shigellosis is severe colitis, and the immediate associated causes are septicemia and pneumonia. Infection with S. dysenterieae type 1 can occur in an epidemic form, and Shigella contaminated food and drink are often the source of epidemic spread. 5

PERFORMANCE CHARACTERISTICS: Sensitivity and specificity It was performed an evaluation using Rapid-VIDITEST Shigella dysenteriae Card/Blister. It was studied some stool samples and the results were confirmed by culture. Rapid- VIDITEST Shigella dysenteriae Card/Blister test showed >99% of sensitivity and >99% of specificity. The antibodies used to elaborate this test recognise Shigella dysenteriae epitopes found in stool of patients, as well as in preparations from the bacteria cultures in vitro. This preliminary value has to be taken with precaution until more evaluation data will be available. Cross-reactivity It was performed an evaluation to determine the cross reactivity of Rapid-VIDITEST Shigella Card/Blister. There is not cross reactivity with common intestinal pathogens, other organisms and substances occasionally present in faeces: H. pylori, Escherichia coli O157:H7, Listeria monocytogenes, Campylobacter spp., Salmonella spp. STORAGE AND STABILITY: Store as packaged in the sealed pouch either at refrigerated or room temperature (2-30ºC/36-86ºF). The test is stable through the expiration date printed on the sealed pouch. The test must remain in the sealed pouch until use. Do not freeze. PRECAUTIONS: - For professional in vitro diagnostic use only. - Do not use after expiration date. - The test should remain in the sealed pouch until use. - Do not use the test if pouch is damaged. - Follow Good Laboratory Practices, wear protective clothing, use disposal gloves, do not eat, drink or smoke in the area. - All the specimens should be considered potentially hazardous and handled in the same manner as an infectious agent. - The test should be discarded in a proper biohazard container after testing. - The test must be carried out within 2 hours of opening the sealed bag. REFERENCES: 1. OPINTAN J.A., et al. Distribution of Serogroups and Serotypes of Multiple Drug Resistant Shigella Isolates Ghana Medical Association 2007. 2. Welton I., et al. Isolation of Shigellae. VI. Performance of Media with Stool Specimens. Applied Microbiology, Sept. 1968, Vol. 16, No. 9, p. 1387-1393. SYMBOLS FOR IVD COMPONENTS AND REAGENTS: In vitro diagnostic device Use by Batch code Manufacturer Last Revision: September 2011 6