chapter 28 Manuel Muro, 1 Santiago Llorente, 2 Maria J. Gónzalez-Soriano, 2 Alfredo Minguela, 1 Luisa Gimeno, 2 and María R.

Similar documents
Evaluation of Two New Antibody Detection Techniques in Kidney Transplantation. Doctoral Thesis. Dr. Petra Gombos

HLA and Non-HLA Antibodies in Transplantation and their Management

Post-Transplant Monitoring for the Development of Anti-Donor HLA Antibodies

Why so Sensitive? Desensitizing Protocols for Living Donor Kidney Transplantation

Posttransplant Human Leukocyte Antigen Antibodies in Stable Kidney Transplant Recipients

Management of Rejection

Virtual Crossmatch in Kidney Transplantation

Even in this era of efficient immunosuppression, a positive

Transplantation in highly sensitised patients treated with intravenous immunoglobulin and Rituximab

Organ transplantation in Bulgaria

Clinical Study Different Impact of Pretransplant Anti-HLA Antibodies Detected by Luminex in Highly Sensitized Renal Transplanted Patients

Donor-Specific HLA Class I and CREG Antibodies in Complement-Dependent Cytotoxicity-Negative Renal Transplants

Transplantation. Immunology Unit College of Medicine King Saud University

IMMUNOBIOLOGY OF TRANSPLANTATION. Wasim Dar

23/10/2017. Panel Reactive Antibodies and Crossmatch by Flow Cytometry. Antibodies against. Renal transplantation. Antibody mediated rejection (AMR)

Effects of HLA-Matched Blood Transfusion for Patients Awaiting Renal Transplantation

FIT Board Review Corner March 2016

The new Banff vision of the role of HLA antibodies in organ transplantation: Improving diagnostic system and design of clinical trials

10/18/2012. A primer in HLA: The who, what, how and why. What?

Predicting Kidney Graft Failure by HLA Antibodies: a Prospective Trial

C4d Fixing, Luminex Binding Antibodies A New Tool for Prediction of Graft Failure After Heart Transplantation

Renal Pathology- Transplantation. Eva Honsova Institute for Clinical and Experimental Medicine Prague, Czech Republic

Robert B. Colvin, M.D. Department of Pathology Massachusetts General Hospital Harvard Medical School

Pre-transplant donor specific antibody and its clinical significance in kidney transplantation

Antihuman leukocyte antigen (HLA) antibodies can be

Dr. Yi-chi M. Kong August 8, 2001 Benjamini. Ch. 19, Pgs Page 1 of 10 TRANSPLANTATION

Mary Keogan, on Mary behalf Keogan of all in NHISSOT On behalf of all in NHISSOT. 4th April 2014

Copyright information:

Peritubular capillaries C4d deposits in renal allograft biopsies and anti HLA I/II alloantibodies screening Incidence and clinical importance

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Transplant Applications of Solid phase Immunoassays Anti HLA antibody testing in solid organ transplantation

Methodologies for Anti-HLA Antibody Screening in Patients Awaiting Kidney Transplant: A Comparative Study

25/10/2017. Clinical Relevance of the HLA System in Blood Transfusion. Outline of talk. Major Histocompatibility Complex

Approach to Kidney Transplant in Sensitized Potential Transplant Recipients

Review of Rituximab and renal transplantation. Dr.E Nemati. Professor of Nephrology

Serum samples from recipients were obtained within 48 hours before transplantation. Pre-transplant

HLA antibody screening strategy in patients awaiting kidney transplantation

The Acceptable Mismatch program of Eurotransplant.

Transfer of HLA-Specific Allosensitization From a Highly Sensitized Deceased Organ Donor to the Recipients of Each Kidney

Cases: CMV, HCV, BKV and Kidney Transplantation. Simin Goral, MD University of Pennsylvania Medical Center

Treatment of choice for end stage renal disease Imaging to establish baseline and diagnosis of potential complications Review common surgical

The MHC and Transplantation Brendan Clark. Transplant Immunology, St James s University Hospital, Leeds, UK

XM-ONE XM-ONE XM-ONE. References XMO_V4.0_100205_CE.EU

Human Leukocyte Antigens and donor selection

2017 BANFF-SCT Joint Scientific Meeting. BARCELONA March 2017

Antibody-Mediated Rejection in the Lung Allograft. Gerald J Berry, MD Dept of Pathology Stanford University Stanford, CA 94305

The role of HLA in Allogeneic Hematopoietic Stem Cell Transplantation and Platelet Refractoriness.

Basel - 6 September J.-M. Tiercy National Reference Laboratory for Histocompatibility (LNRH) University Hospital Geneva

Case Presentation Turki Al-Hussain, MD

Evaluation of Two New Antibody Detection Techniques in Kidney Transplantation

Background & objectives

3/6/2017. Prevention of Complement Activation and Antibody Development: Results from the Duet Trial

Chapter 10. Histocompatibility Testing

6/19/2012. Who is in the room today? What is your level of understanding of Donor Antigens and Candidate Unacceptables in KPD?

Antibody Mediated Rejection (AMR) in LUNG TRANSPLANT Recipients

Should red cells be matched for transfusions to patients listed for renal transplantation?

IMPACT OF PREFORMED AND DE NOVO ANTI-HLA DP ANTIBODIES

The Human Major Histocompatibility Complex

Pediatric Transplantation DOI: /j x

APHERESIS FOR DESENSITIZATION OF NON-RENAL TRANSPLANTS

Histocompatibility Evaluations for HSCT at JHMI. M. Sue Leffell, PhD. Professor of Medicine Laboratory Director

Chronic Kidney Disease (CKD) Stages. CHRONIC KIDNEY DISEASE Treatment Options. Incident counts & adjusted rates, by primary diagnosis Figure 2.

NONSPECIFIC Starts in the blood by

Quantifying HLA-specific antibodies in patients undergoing desensitization Andrea Zachary a and Nancy L. Reinsmoen b

Research Article The Diagnostic Value of Transcription Factors T-bet/GATA3 Ratio in Predicting Antibody-Mediated Rejection

Renal Transplant. Tony Chacon. Program Head BCIT Nephrology Nursing Program.

Overview. Evaluation of Potential Kidney Transplant Recipients. Projected Years of Life in Patients with ESRD

Solid Organ Transplantation 1. Chapter 55. Solid Organ Transplant, Self-Assessment Questions

Predicting HLA Class II Alloantigen Immunogenicity From the Number and Physiochemical Properties of Amino Acid Polymorphisms

XIV. HLA AND TRANSPLANTATION MEDICINE

Renal transplantation in sensitized recipients with positive luminex and negative CDC (complement-dependent cytotoxicity) crossmatches

Supplementary appendix

AMR in Liver Transplantation: Incidence

Clinical Relevance of the HLA System in Blood Transfusion. Dr Colin J Brown PhD FRCPath. October 2017

1. Discuss the basic pathophysiology of end-stage liver and kidney failure.

Review Article Clinical Relevance of HLA Antibody Monitoring after Kidney Transplantation

Antibodies against MICA Antigens and Kidney-Transplant Rejection

Autoimmunity & Transplantation. Dr. Aws Alshamsan Department of Pharmaceu5cs Office: AA87 Tel:

Understanding crossmatch testing in organ transplantation: A case-based guide for the general nephrologistnep_

Original Article Diagnostic Immunology INTRODUCTION

Transfusion support in Transplantation

Kidney paired donation in the presence of donor-specific antibodies

Completing the CIBMTR Confirmation of HLA Typing Form (Form 2005)

Human leukocyte antigen (HLA) matching has a beneficial

Focal peritubular capillary C4d deposition in acute rejection

Living-Donor Kidney Transplant in T-Cell and B-Cell Flow Cytometry Crossmatch-Positive Patients

Donor-derived Cell-free DNA Improves DSA-informed Diagnosis of ABMR in Kidney Transplant Patients

Glossary. Anesthesiologist A doctor who puts you or parts of your body to sleep during surgery.

Welche Donor-spezifischen HLA Antikörper sind schädlich?

- Transplantation: removing an organ from donor and gives it to a recipient. - Graft: transplanted organ.

Immunopathology of T cell mediated rejection

Strategies for Desensitization

RevIeWS. Sensitized renal transplant recipients: current protocols and future directions. James Gloor and Mark D. Stegall

ABO Antibody Titer and Risk of Antibody-Mediated Rejection in ABO-Incompatible Renal Transplantation

Immunosuppressants. Assistant Prof. Dr. Najlaa Saadi PhD Pharmacology Faculty of Pharmacy University of Philadelphia

Patient Education Transplant Services. Glossary of Terms. For a kidney/pancreas transplant

CASE REPORT ABSTRACT INTRODUCTION. Renal transplant was successfully performed after conversion.

HLA Antibody Complement Based Assays. Howard M. Gebel, PhD, D(ABHI) Robert A. Bray, PhD, D(ABHI) Emory University Hospital Atlanta, GA

Transcription:

chapter 28 Pre-formed Donor-Specific Alloantibodies (DSA) Detected Only by Luminex Technology Using HLA-Coated Microspheres and Causing Acute Humoral Rejection and Kidney Graft Dysfunction Manuel Muro, 1 Santiago Llorente, 2 Maria J. Gónzalez-Soriano, 2 Alfredo Minguela, 1 Luisa Gimeno, 2 and María R. Álvarez-López 1 Departments of 1 Immunology and 2 Nephrology, University Hospital Virgen de la Arrixaca, Spain 379 Introduction Classically, sensitization is defined as the presence of pre-formed alloantibodies (usually anti-hla class I antibodies but sometimes anti- HLA class II or non-hla antibodies as well) in the serum of a prospective transplant recipient. Sensitization is measured by testing the patient s serum for cytotoxicity against a panel of lymphocytes with various HLA types. The donor vascular endothelium is the major target of alloantibody, particularly the microcirculation. The target organ is destroyed by the ability of donor-specific antibodies (DSA) to recruit effector systems including complement, leukocytes including neutrophils, natural killer cells, and macrophages (1). Thus, a positive T-cell cross-match is an absolute contraindication to transplantation because of the risk of hyperacute rejection and immediate graft dysfunction and loss. Indeed, alloantibodies not only may cause hyperacute rejection, the most severe type of humoral graft injury, but also may contribute to other types of rejections, such as acute or chronic rejection (2,3). This work presents a very interesting clinical case with respect to pre-sensitization of a patient and the different methods used to analyze this sensitization which, when not properly detected, may play an important role in the outcome of a clinical transplant. Case A 45-year-old woman with end-stage renal disease (renal polyquistosis) was transplanted in our hospital. Four years before admission, the patient s base-line creatinine concentration began rising from her usual level of 3.4 mg per deciliter; three and a half years before admission, renal failure occurred and hemodyalisis was begun. There was no history of chest pain, dyspnea, cough, fever, or vomiting. The patient did not use tobacco, alcohol, or illicit drugs. Tests for hepatitis B surface antigen and for antibodies to hepatitis C were negative, as was a serologic test for VIH, although antibodies to cytomegalovirus were positive. She was apparently not sensitized to HLA antigens and had a panel-reactive antibody (PRA) level approching 0% by standard complementdependent citotoxicity (CDC) technique; she was also without previous transfusion history and transplants (with inclusion into the waiting list 3 year ago). Before transplantation, cross-matching of the patient s serum and the donor s T- and B-cells by standard CDC as- alloantibodies (dsa) Clinical Transplants 2006, Terasaki Foundation Laboratory, Los Angeles, California

380 muro, llorente, gonzalez-soriano, et al say was negative. This cross-match test (with extended times for more sensitivity) was performed as previously published (4,5). On the evening of admission, transplantation of a left cadaveric kidney into the left iliac fossa was performed without incident, except that endarterectomy of the left common iliac artery was necessary before creation of the anastomosis; the transplantation then became pink, and a left popliteal pulse was palpable. The flow of urine was sluggish until furosamida, mannitol, and fluid were infused. On the post-transplant hospital days, prednisone, dopamine, albumin, mycophenolate mofetil, ranitidine, and tacrolimus were given. On the second hospital day, two units of packed red cells were transfused, and ecography was apparently normal, although initial oliguria persisted despite the administration of furosamide and mannitol. There was no hydronephrosis. Doppler evaluation of the renal artery showed that the resistive index (RI) was slighty elevated (0.78), and no perinephric collection of fluid was identified. On the third hospital day, radionuclide scanning indicated that perfusion of the transplanted kidney was severely reduced, with a parallel decrease in renal function manifested as impared uptake and clearance of tracer activity. Doppler evaluation showed that the RI was more elevated (1.0), indicating that diastolic flow in the transplanted kidney is poor. The next day, surgical exploration revealed a well-perfused allograft that appeared healthy but felt soft; a wedge biopsy was obtained. In the examination of the frozen sections, the patient presented facts that were strongly suggestive of acute humoral rejection, as published (6,7). Humoral (or antibody-mediated) rejection is characterized by an aggregation of neutrophils in the peritubular capillaries and glomeruli, fibrin thrombi in the capillaries, vasculitis, and occasional fibrinoid necrosis of the vessel walls. Moderate focal interstitial edema and clusters of tubules lines by flattened epithelium indicated tubular injury without thrombosis. The next day, plasmapheresis and 3 boluses of methylprednisolone (500 mg per bolus) treatment were begun, and surgical exploration revealed a globular allograft that maintained conserved arterial and venose flow. On the seventh day, due to a decreased hematocrit, two units of packed red cells were transfused, and echography indicated perirrenal hematuria and abdominal pain. Surgical procedure showed a violet graft with a thrombosed vein and perirrenal bruise; thus the kidney allograft was removed. Post-transplantation cross-match by CDC assay with serum drawn at the time of the first biopsy was strongly positive, as would be expected in a case of acute humoral rejection; CDC (PRA = 53.2%), ELISA (GTI Diagnostic, Waukesha, WI) (PRA = 61.2%) and FlowPRA (OneLambda, Inc., CA) (PRA = 68.3%) antibody screenings were also performed. FlowPRA microparticle evaluations were administered according to the manufacturer s recommended procedures, as previously published (5). ELISA and Flow- PRA methods also detected antibodies that are not cytotoxic in a standard CDC (i.e., noncomplement-fixing antibodies). This latter assay also showed that these detected antibodies were anti-immunoglobulin G (IgG) antibodies. Indeed, we detected an anti-a2 antibody in this screening (the donor s typing had A2) in high titer. Then we performed ELISA and FlowPRA screening in the pre-transplant sera and received similarly negative results, confirming the previous pre-transplantation CDC screening. Figure 1 shows the comparison between preand post-transplantation FlowPRA determination. In view of these conflicting results and due to the new luminex technology available in our laboratory (Labscreen, OneLambda), we applied it and found in the pre-transplant sera anti- A2 and anti-b7 antibodies in low titer, which had not been detected with CDC, ELISA, and Flow- PRA technologies.

381 HLA class I and II typings of the patient, donor, husband, and sons are summarized in Table 1. Two of the patient s sons presented A2, B7, DR15, and DQ6 mismatches, while their mother and the other son presented A2, DR4, and DQ8 mismatches. Indeed, crossmatching of the patient s pretransplant serum and the son s and husband s T- and B-cells by standard CDC assay was negative, and the post-transplant serum was positive. Figure 1. FlowPRA screening in pre- and post-transplant sera in our patient. The histograms show the presence of IgG antibodies in the post-transplant serum and the ausence in the pre-transplant serum. Table 1. HLA Class I and II Typing of the Patient, Organ Donor, Husband, and Sons HLA Locus A Locus B Locus DRB1 Locus DQB1 Patient A23, A32 B8, B44 DRB1*07, *13 DQB1*02, *04 Organ Donor A2, A29 B8, B44 DRB1*03, *07 DQB1*02, *02 Husband A2, A2 B7, B44 DRB1*04, *15 DQB1*03, *06 First Son A2, A23 B7, B8 DRB1*13, *15 DQB1*06, *06 Thus, sensitization of the patient was probably caused by previous exposure to alloantigens such as multiple pregnancies and deliveries with exposure to paternal HLA antigens expressed by fetal cells. These alloantibodies are directed against class I and II molecules, generally as high-affinity IgG. The patient probably had low titers of pre-transplant anti-donor antibodies that were not detected prospectively by the lymphocytotoxicity and flow cytometry assays. These antibodies were retrospectively detected by luminex technology when the patient had graft loss, but they might have been detected before transplantation. alloantibodies (dsa) Second Son A2, A23 B7, B8 DRB1*13, *15 DQB1*06, *06 Discussion Third Son A2, A23 B8, B44 DRB1*04, *13 DQB1*04, *03 Therefore, we performed familiar typing on the patient s sons (the patient had three sons and two abortuses; her last pregnancy was 17 year ago). HLA-A and -B class I antigens were determined using the standard microlymphocytotoxicity technique (4,8). HLA-DRB1 and -DQB1 genotyping were performed by the PCR-SSP method (One Lambda), as previously published (9). For more than 30 years, the CDC assay has been standard for the detection of preformed anti-hla antibodies in the sera of potential kidney transplant recipients. This assay has been criticized for not being able to detect noncomplement binding, low affinity, or low titer antibodies. However, the clinical relevance in kidney transplantation of additional antibodies detected by the more sensitive ELISA and flow cytometry techniques is a matter of debate

382 muro, llorente, gonzalez-soriano, et al (2,3,10). In this sense, there are other articles comparing the different methods of HLA antibodies screening (11), although there are limited articles in which the clinical relevance and consequences of these comparisons are clear and manifiest. The present article shows a clear difference between these methods, and this difference is of major clinical importance; in our case, only the luminex technology was able to identify the patient s antibodies, and these were strongly deleterious for allograft outcome. Although antibody-mediated rejection is associated with increased graft loss (1), recovery of renal function can generally be achieved with aggressive early treatment. The important purpose of all therapeutic modalities is the removal of alloantibodies or the control of their production. The attractive treatment of early antibody-mediated rejection is the removal of alloantibodies by plasmapheresis or immunoadsorption with or without the immunosuppressive agents. However, this type of treatment was not sufficient to avoid the graft loss suffered by our patient. Another curious point of this clinical case is that the patient had circulating antibodies, which were the result of a sensitizing event that occurred 17 years ago; these antibodies in low titer could produce an immune response conducive to graft failure in spite of immunosuppressive regimen. In patients with pre-existing and long-standing alloantibody responses, however, immunosuppressives may have little effect, possibly due to long-lived plasma cells (1). The longevity of antibody responses is maintained by the presence of these long-lived plasma cells or by the persistence of antigen. Long-term antibody responses, however, are maintained by nondividing, long-lived plasma cells that produce high-affinity antibody and reside mainly in the bone marrow. Survival of long-lived plasma cells is regulated by the competition of limited survival niches. Once in survival niches, the persistence of long-lived plasma cells does not require the presence of antigen (12). In our case, the presence of low-titer antibodies in the recipient or the activation of memory B cells could have mediated these facts since IgG antibodies were present. In this sense, following transplantation, exposure to antigen can stimulate memory cells, resulting in an amnestic response and rapid production of anti- HLA antibodies. Indeed, in rejection, the strong INF-γ production in the graft ensures high MHC expression and allows IgG alloantibodies to effectively activate complement (1). On the other hand, this case report underlines the importance both of identifying patients who are sensitizied by using several screening methods and of cross-matching with historical sera. At least some antibody-mediated rejection can probably be prevented by very sensitive screening and cross-matching methods. Indeed, luminex technology has recently been noted as more sensitive than other techniques for antibody detection (13). summary The different methodologies for the detection of HLA sensitization could have discrepant results. At the moment, luminex technology seems in our opinion to be the most sensitive and safest method for antibody detection, and it should be taken into account during the transplantation process and as a means of indicating immunossuppresive regimen modulation.

383 References 1. Vongwiwatana, A., Tasanarong, A., Hidalgo, L.G., and Halloran, P. The role of B cells and alloantibody in the host response to human organ allografts. Immunol Rev (2003); 196: 197 218. 2. Susal, C. and Opelz, G. Kidney graft failure and presensitization against HLA class I and class II antigens. Transplantation (2002); 73: 1269 1273. 3. Terasaki, P.I. and Ozawa, M. Predicting kidney graft failure by HLA antibodies: a prospective trial. Am J Transplant (2004); 4: 438 443. 4. Ontañón, J., Muro, M., García-Alonso, A.M. et al. Effect of partial HLA-class I match on acute rejection in viral pre-infected human liver allograft recipients. Transplantation (1998); 65: 1047 1053. 8. Muro, M., Marín, L., Torío, A. et al. HLA polymorphism in the Murcia population (Spain) in the cradle of the archaeologic Iberians. Hum Immunol (2001); 62: 910 921. 9. Muro, M., Álvarez-López, M.R., Torío, A. et al. HLA- DRB1 and -DQB1 polymorphism in liver recipients: relationship between HLA-DQB1*0302 allele frequency and acute rejection. Hum Immunol (1997); 56: 70 76. 10. Férnandez-Fresnedo, G., Pastor, J.M., López- Hoyos, M. et al. Relationship of donor-specific class-i anti-hla antibodies detected by ELISA after kidney transplantation on the development of acute rejection and graft survival. Nephrol Dial Transplant (2003); 18: 990 995. 5. Muro, M., Sánchez-Bueno, F., Marín, L. et al. Relationship between CDC cross-match in liver recipients and antibodies screening by flow cytometry. Transplant Proc (2003); 35: 1894 1895. 6. Böhmig, G.A., Exner, M., Habicht, A. et al. Capillary C4d deposition in kidney allografts: a specific marker of alloantibody-dependent graft injury. J Am Soc Nephrol (2002); 13: 1091 1099. 7. Sayegh, M.H. and Colvin, R.B. Case 8 (2003): a 35- year-old man with early dysfunction of a second renal transplant. N Eng J Med (2003); 348: 1033 1044. 11. Dyer, P.A., Taylor, C., and Martin, S. HLA and clinical solid organ transplantation: recent publications and novel approaches. HLA (1998); 13 45. 12. Slifka, M.K., Antia, R., Whitmire, J.K., and Ahmed, R. Humoral immunity due to long-lived plasma cells. Immunity (1998); 8: 363 372. 13. Pretl, K., Chesterton, K.A., Scholander, J.T., Leffell, M.S., and Zachary, A.A. Accurate, rapid characterization of HLA-specific antibody using luminex technology. Hum Immunol (2003); 64: S108. alloantibodies (dsa)