Published December 16, 2010 as /ajnr.A2314

Similar documents
Endovascular treatment of intracranial aneurysms has been

Development of endovascular occlusion devices has been

Pipeline Embolization Device

HHS Public Access Author manuscript J Neurointerv Surg. Author manuscript; available in PMC 2016 April 28.

A Collagen-Based Coil for Embolization of Saccular Aneurysms in a New Zealand White Rabbit Model

Angiographic and Histologic Analysis of Experimental Aneurysms Embolized with Platinum Coils, Matrix, and HydroCoil

Role, safety, and efficacy of WEB flow disruption: a review

Serial Angiography in an Elastase-induced Aneurysm Model in Rabbits: Evidence for Progressive Aneurysm Enlargement after Creation

Coiling of ruptured and unruptured intracranial aneurysms

Endovascular treatment with coils has become an established

Endovascular treatment is increasingly used for ruptured

Endovascular coil embolization of cerebral aneurysms is associated

Coil embolization of ruptured intracranial aneurysms leads

Usefulness of Coil-assisted Technique in Treating Wide-neck Intracranial Aneurysms: Neck-bridge Procedure Using the Coil Mass as a Support

Time-resolved Magnetic Resonance Angiography for assessment of recanalization after coil embolization of visceral artery aneurysms

Mo d i f i c at i o n s to platinum coils have been proposed. Evaluation of the new HydroSoft coil in a canine model of bifurcation aneurysm

NIH Public Access Author Manuscript J Am Coll Radiol. Author manuscript; available in PMC 2013 June 24.

Rescue Balloon Reposition of the Protruding Coil Loops during Endovascular Treatment of An Anterior Communicating Artery Aneurysm: A Case Report

Subarachnoid hemorrhage secondary to ruptured intracranial

Endovascular embolization of intracranial aneurysms

Jean Raymond, Igor Salazkin, Annick Metcalfe, François Guilbert, Alain Weill, and Daniel Roy. AJNR Am J Neuroradiol 24: , October 2003

The treatment of wide-neck and giant intracranial aneurysms

Endovascular treatment of intracranial aneurysms with bare

Introducing a New Treatment Method for Brain Aneurysms

Shallow aneurysms with wide necks pose a technical challenge

Ruptured intracranial vertebral confluence

Can Flow diverters be used in acute SAH

Endovascular embolization with detachable coils has become

Endovascular coil embolization is an effective and popular

Saccular intracranial aneurysms are characterized pathologically

Shallow aneurysms with wide necks pose a technical challenge

UPSTATE Comprehensive Stroke Center

THE POWER OF HYDROGEL

High-Flow, Small-Hole Arteriovenous Fistulas: Treatment with Electrodetachable Coils

Intracranial aneurysms are an important health problem

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE Medical technology guidance SCOPE Pipeline embolisation device for the treatment of

ORIGINAL PAPER. 8-F balloon guide catheter for embolization of anterior circulation aneurysms: an institutional experience in 152 patients

Intravascular stents for intracranial internal carotid and vertebral artery aneurysms: preliminary clinical experience

ORIGINAL PAPER. Hemispheric divided coiling technique for coil embolization of middle- and large-sized intracranial aneurysms

The standard examination to evaluate for a source of subarachnoid

CONCLUSIONS: In this large prospective series of patients, WEB flow disruption was a safe and efficient technique.

Ruby Coil. Large Volume Detachable Coils

Long term follow-up of patients with coiled intracranial aneurysms Sprengers, M.E.S.

Flow-diversion devices have been approved by the. Patency of the ophthalmic artery after flow diversion treatment of paraclinoid aneurysms

Neurosurgical decision making in structural lesions causing stroke. Dr Rakesh Ranjan MS, MCh, Dip NB (Neurosurgery)

Endovascular treatment is now the preferred treatment option

Selective Endovascular Treatment of Intracranial Aneurysms with a Liquid Embolic: A Single-Center Experience in 39 Patients with 41 Aneurysms

Endovascular treatment can significantly improve the outcomes

A single center comparison of coiling versus stent assisted coiling in 90 consecutive paraophthalmic region aneurysms

Flow diverters are flexible microcatheter-delivered selfexpanding

A Novel Technique of Microcatheter Shaping with Cerebral Aneurysmal Coil Embolization: In Vivo Printing Method

Two decades ago, the development of detachable coils marked

Long-term effects of antiplatelet drugs on aneurysm occlusion after endovascular treatment

Understanding aneurysms and flow diversion treatment

Coil embolization of intracranial aneurysms is prone to recurrence

LVIS Intraluminal Stent Device: Separates itself from other stents used in treatments for aneurysm with recent PMA FDA approval

Endovascular Treatment of Intracranial Anterior Circulation Aneurysms with Flow Diverters: A Single Centre Experience with Mid- and Long-Term Results

Aneurysm Embolization: Coiling

Studying Aneurysm Devices in the Intracranial Neurovasculature

Endovascular treatment of intracranial aneurysms with detachable

Epidemiology And Treatment Of Cerebral Aneurysms At An Australian Tertiary Level Hospital

Quality Metrics. Stroke Related Procedure Outcomes

Y-Stent-Assisted Coil Embolization of Anterior Circulation Aneurysms

Endovascular treatment of intracranial aneurysms by coiling

From its clinical introduction in 1991 in nonsurgical patients

Thrombosis in Giant Basilar Tip Aneurysms during Coil Embolization

What You Should Know About Cerebral Aneurysms

Aneurysm Embolization: Coiling, Stenting, & Flow Diversion

To coil or not to coil? How to pick the right treatment of intracranial aneurysms.

Case Report 1. CTA head. (c) Tele3D Advantage, LLC

Comparison between Solitaire AB and Enterprise stent assisted coiling for intracranial aneurysms

Intraprocedural aneurysmal rupture is one of the most feared

Original Article Occlusion of lateral aneurysm in common carotid artery of rabbits with flow-diverting stent

Novel non-occlusive temporary endoluminal neck protection device to assist in the treatment of aneurysms in a canine model

Dept. of Neurosurgery, Division of Endovascular Neurosurgery, Medilaser Clinic, Tunja, Colombia 2

Embolization with detachable coils is a safe and effective

The incidence of subarachnoid hemorrhage (SAH) increases

Endovascular treatment (EVT) of intracranial aneurysms is an

Endovascular treatment of cerebral aneurysms using the Woven EndoBridge technique in a single center: preliminary results

Case Report. Case Report

Flow diverters are increasingly used to treat large, giant, and,

Treatment of Unruptured Vertebral Artery Dissecting Aneurysms

SURPASS FLOW DIVERTER

Interlocking Detachable Coil Occlusion in the Endovascular Treatment of Intracranial Aneurysms: Preliminary Results

Detection & Treatments

Yoshikazu Matsuda, 1,2 Joonho Chung, 1,3 Kiffon Keigher, 1 Demetrius Lopes 1 ORIGINAL RESEARCH. New devices

The Importance of Coil Packing

Superior cerebellar artery aneurysms: incidence, clinical presentation and midterm outcome of endovascular treatment

Use of a Flow Re-direction Endoluminal Device (FRED) for Wide-neck Large/Giant Cerebral Aneurysms

Treatment of intracranial aneurysms with bare platinum

Limitations of thrombolysis, including low recanalization

History of the Powerlink System Design and Clinical Results. Edward B. Diethrich Arizona Heart Hospital Phoenix, AZ

Large and giant aneurysms are associated with much worse outcomes

An Overview of Post-EVAR Endoleaks: Imaging Findings and Management. Ravi Shergill BSc Sean A. Kennedy MD Mark O. Baerlocher MD FRCPC

Practical Feasibility and Packing Density of Endovascular Coiling Using Target Nano TM Coils in Small Cerebral

Enterprise Stent-assisted Cerebral Aneurysm Coiling: Can Antiplatelet Therapy be Terminated after Neointima Formation with the Enterprise Stent?

Neuroform Microdelivery Stent System

Aneurysms of the posterior inferior cerebellar artery

Initial experience with implantation of novel dual layer flow-diverter device FRED

Transcription:

Published December 16, 2010 as 10.3174/ajnr.A2314 ORIGINAL RESEARCH S.C. Kwon Y.H. Ding D. Dai R. Kadirvel D.A. Lewis D.F. Kallmes Preliminary Results of the Luna Aneurysm Embolization System in a Rabbit Model: A New Intrasaccular Aneurysm Occlusion Device BACKGROUND AND PURPOSE: Recent advances in endovascular devices have been aimed at providing high density, mesh-like metallic materials across the aneurysm neck, in place of coil technology. Therefore our aim was to report the in vivo preclinical performance of a self-expanding intrasaccular embolization device. MATERIALS AND METHODS: Elastase-induced aneurysms were created in 12 rabbits. Each aneurysm was embolized with a Luna AES. DSA was performed preimplantation; 5, 10, and 30 minutes postimplantation; and at 1 month in 12 rabbits and at 3 months in 8 rabbits. Early postimplantation intra-aneurysmal flow was graded as unchanged, moderately diminished, or completely absent. Oneand 3-month DSAs were graded by using a 3-point scale (complete, near-complete, or incomplete occlusion). Aneurysms were harvested for gross and microscopic histologic evaluation at 1 month (n 4) and at 3 months (n 8). Tissues within the aneurysm dome and across the aneurysm neck were assessed by using HE staining. RESULTS: Ten (83%) of 12 aneurysms demonstrated complete cessation of flow within 30 minutes of device implantation. At 1-month follow-up, 10 (83%) of 12 aneurysms were completely occluded. At 3 months, 7 of 8 (88%) aneurysms remained completely occluded. One-month gross examination in 4 rabbits demonstrated that membranous tissue completely covered the device in 3 subjects (75%). Microscopic examination showed that 3 aneurysms had loose connective tissue filling the aneurysm cavity. Three-month gross and microscopic examinations demonstrated membranous tissue completely covering the device, loose connective tissue filling the aneurysm cavity, and neointima formation crossing the aneurysm neck in 8 of 8 (100.0%) subjects. Received June 14, 2010; accepted after revision July 30. From the Department of Neurosurgery (S.C.K.), Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan, Republic of Korea; and Department of Radiology (S.C.K., Y.H.D., D.D., R.K., D.A.L., D.F.K.), Mayo Clinic, Rochester, Minnesota. This study was funded by NFocus Neuromedical, Palo Alto, California. Please address correspondence to David F. Kallmes, MD, Mayo Clinic College of Medicine, 200 First St SW, Rochester, MN 55905; e-mail: Kallmes.david@mayo.edu DOI 10.3174/ajnr.A2314 CONCLUSIONS: The Luna AES achieved high rates of complete angiographic occlusion and showed promising histologic findings in the rabbit aneurysm model. ABBREVIATIONS: AES Aneurysm Embolization System; An. aneurysm; CA completely absent; CO complete occlusion; DSA digital subtraction angiography; HE hematoxylin-eosin; IVDSA intravenous digital subtraction angiography; MD moderately diminished; NO nearcomplete occlusion The goals of endovascular procedures for the treatment of cerebral aneurysms are to exclude the aneurysm sac from the cerebral arterial circulation and preserve parent vessel patency. There are 2 main categories of endovascular aneurysm treatment, intrasaccular and endoluminal procedures. The safety and efficacy of intrasaccular detachable coil embolization is well documented 1-3 but has limitations. Even with evolving procedural techniques and technology, the rate of aneurysmal total occlusion remains suboptimal. 4,5 The prevalence of coil compaction, which results in posttreatment recanalization and recurrence, is frequent. 4,6,7 Conceptually, endoluminal flow diverters direct blood flow away from the aneurysm cavity primarily by placing a stent-like device across the aneurysm neck. However, flow diverters have had limited clinical utility, though they have shown excellent occlusion rates, even in large and giant aneurysms. 8-12 These devices may remain problematic in ruptured aneurysms, not only because they require concomitant use of dual antiplatelet therapy but also because immediate aneurysm occlusion usually does not occur. Furthermore, there are drawbacks when placing these devices in bifurcation aneurysms due to the inherent design limitations. In the present study, we describe the in vivo performance of a new type of embolization device. This new device, the Luna AES (NFocus Neuromedical, Palo Alto, California) is a selfexpanding ovoid braided implant that when placed into an aneurysm cavity, provides an attenuated mesh of metal across the neck. The purpose of this study was to evaluate the safety, performance, and efficacy of the Luna AES in the rabbit elastase-induced aneurysm model. Materials and Methods The endosaccular embolization device was the Luna AES, a self-expanding ovoid ball-like implant with a delivery system (Fig 1). The implant is made from a double layer of nitinol wire mesh secured at both proximal and distal ends and clearly marked with radiopaque platinum markers. A variety of implant diameters is available, as with coils. The delivery system provides distal navigation through a commercially available microcatheter with detachment controlled by operator activation of the delivery handle. The unexpanded profile for INTERVENTIONAL ORIGINAL RESEARCH Copyright 2010 by American Society of Neuroradiology. AJNR Am J Neuroradiol : 2011 www.ajnr.org 1

the aneurysm, it was recaptured and removed, and a different size Luna was placed in the aneurysm. After embolization, DSA of the aortic arch and brachiocephalic vessels was performed at 5, 10, and 30 minutes following device implantation. The catheter and vascular sheath were removed, and the proximal aspect of the femoral artery was ligated with a 4 0 suture. IVDSA for all subjects followed at 1 month. DSA of the aortic arch was performed at the time of sacrifice, either 1 month (n 4), or 3 months (n 8). Animals were then euthanized with a lethal injection of pentobarbital. The harvested embolized aneurysms and aorta were immediately fixed in 10% neutral buffered formalin. Fig 1. The Luna AES. each is 1.9F, approximately 0.025 inches that is, devices can be delivered through a commercially available standard microcatheter with a 0.027-inch lumen. In this study, Luna devices were delivered with a 5F guiding catheter. In Vivo Experiments Aneurysms (n 12) were created in New Zealand white rabbits as previously described. 13 Aneurysms were allowed to mature for at least 21 days before embolization. Anesthesia was induced by using 74-mg/kg ketamine, 5-mg/kg xylazine, and 1-mg/kg acepromazine and was maintained by using ketamine (10 mg/kg) and xylazine (3 mg/kg). Using a sterile technique, we performed surgical cutdown of the right common femoral artery and a 5F vascular sheath was inserted. Heparin (100 U/kg) was administered intravenously. A 5F guide catheter (Envoy; Cordis Neurovascular, Miami Lakes, Florida) was placed into the aortic arch, and DSA was performed. Following the DSA, the aneurysm size (neck, width, and height) was determined by using sizing markers of a known diameter. The catheter was advanced and gently placed into the aneurysm cavity. The Luna device size was selected to match each aneurysm on the basis of the average of the aneurysm height and width. The Luna device was delivered into the aneurysm cavity via the 5F guide catheter by using the Luna delivery system and was deployed. If the Luna was not the correct size for Angiographic Evaluation DSA was performed at 30 minutes after device implantation. Early postimplantation intra-aneurysmal flow was characterized as unchanged, moderately diminished, or completely absent. IVDSA through catheterization of the ear vein for all 12 rabbits was performed at 1 month. 14 Also DSA, followed by sacrifice, was performed at 1 month (n 4) and 3 months (n 8) after implantation. The follow-up sacrifice angiograms were accomplished by a surgical cutdown of the left femoral artery. A 4F catheter was placed in the aortic arch, and DSA was performed. At the 1- and 3-month follow-ups, we graded the degree of aneurysm occlusion by using a 3-point scale (complete, near-complete, or incomplete occlusion), as previously published. 15 All follow-up angiograms were compared with immediate postembolization angiograms. Device migration within the aneurysm (ie, the position of the device relative to the aneurysmal cavity and parent artery) was assessed at all time points. Histopathology Each dissected aneurysm and adjacent parent artery specimen were fixed in 10% neutral buffered formalin for at least 24 hours. Gross examination of the sample was performed. Specimens were processed by using previously described histologic techniques. 16 Briefly, samples were embedded in paraffin and subsequently sectioned at 1000- m intervals in a coronal orientation, permitting long-axis sectioning of the aneurysm neck, with a slow-speed saw (Isomet; Beuhler, Lake Bluff, Illinois). The metallic material of the device was carefully removed under a dissecting microscope (Leica MZ12.5; North Central Instruments, Minneapolis, Minnesota). After metal was removed, the samples were re-embedded in paraffin and sectioned at 5- and 7- m intervals. Sections were stained with HE. The Summary of serial cases No. Longest Width, Height of An. (mm) Neck, (mm) Size of Luna, (mm) Early Intra- Aneurysmal Flow Follow-Up (mo) Findings on Final Angiogram Gross Findings Microscopic Findings of Aneurysmal Dome Microscopic Findings of Neck 1 3.6 9.6 2.3 5.5 MD 1 NO Membranous tissue Loose connective tissue Thick neointima 2 3.5 11.8 3.0 7.5 CA 1 CO Small empty cavity Loose connective tissue No neointima 3 3.6 6.7 1.6 6 CA 1 CO Membranous tissue Loose connective tissue Thin neointima 4 4.3 7.6 2.0 6 CA 1 CO Membranous tissue Loose connective tissue Thick neointima with unorganized thrombus 5 3.1 8.5 2.5 6 CA 3 CO Membranous tissue Loose connective tissue Thick neointima 6 3.8 9.7 2.5 6 CA 3 CO Membranous tissue Loose connective tissue Thin neointima 7 3.2 8.4 2.4 6 CA 3 CO Membranous tissue Loose connective tissue Thin neointima 8 3.2 12.8 3.6 8 CA 3 CO Membranous tissue Loose connective tissue Thin neointima 9 3.5 9.5 3.2 6 CA 3 CO Membranous tissue Loose connective tissue Thick neointima 10 3.2 7.2 1.5 6 CA 3 CO Membranous tissue Loose connective tissue Thin neointima 11 4.3 12.3 2.5 6.5 MD 3 NO Membranous tissue Loose connective tissue Thin neointima 12 3.6 13 2.9 6.5 CA 3 CO Membranous tissue Loose connective tissue Thin neointima 2 Kwon AJNR 2011 www.ajnr.org

Fig 2. Representative case 5 in the Table. A, Pretreatment DSA demonstrates the aneurysm. B, DSA immediately after placement of Luna AES shows some cessation of intra-aneurysmal flow. C, DSA image at 5 minutes postimplantation shows total occlusion of the aneurysm. D and E, IVDSA at 1 month (D) and DSA at 3 months (E) show total occlusion. F, Gross examination at the neck orifice shows that the device is covered with a translucent membranous tissue. G, Photomicrograph of the aneurysm stained with Hematoxylin and Eosin (H&E; original magnification 12.5 ). This photomicrograph demonstrates that the aneurysmal cavity is filled with loose connective tissue and that a thick layer of neointima crosses the neck interface. H, Photomicrograph (enlargement of box in G) of the aneurysm s neck stained with H&E (original magnification 40 ). This image shows that the neointima consists of spindle cells, which appear to be smooth muscle cell-like. AJNR Am J Neuroradiol : 2011 www.ajnr.org 3

Fig 3. Representative images from case 2 in the Table. A, DSA before treatment shows the aneurysm. B, Image at sacrifice shows a small remnant at the neck. C, Gross examination shows the device is partially covered with membranous tissue, such that the aneurysmal cavity is open to the parent artery through the holes of the device. D, Photomicrograph of the aneurysm stained with H&E (original magnification 12.5 ). The photomicrograph reveals thrombus at the neck, with no neointimal layer, and the remnant seen in B. tissues within the aneurysm dome were categorized as unorganized thrombus, loose connective tissues (organized thrombus or organized tissues), and connective tissue. The neointima across the aneurysmal neck was defined as no neointima, thin neointima (tissues on the stent surface at the neck composed of 3 layers of cells, with minimal extracellular matrix deposition), and thick neointima (neointima containing 3 layers of cells, with or without noticeable collagenous matrix deposition). Results Dimensions of aneurysms and sizes of deployed devices are summarized in the Table. Luna devices were successfully placed in all 12 aneurysms. There were no perioperative complications. At early postimplantation angiography, we confirmed 3 cases of low-lying devices within the parent artery, but no substantial parent artery compromise was noted at any time point. Ten (83%) of 12 aneurysms demonstrated complete cessation of flow within 30 minutes following device implantation (Fig 2C); 2 others, in which slightly undersized devices were used because of limited inventory for this prototype development project, had moderately diminished intra-aneurysmal flow and small neck remnants. At 1 month, all 10 aneurysms that were completely occluded on the early postimplantation angiogram remained completely occluded; the 2 aneurysms with small neck remnants at early postimplantation were nearly completely occluded. At 3 months, 7 of 8 (88%) aneurysms remained completely occluded. The occlusion of 1 other aneurysm remained near-complete. One-month gross examination in 4 specimens revealed membranous tissue completely covering the device in 3 subjects (Fig 2E); a single subject had an aneurysm cavity that was open to the parent artery through the bare holes of the device (Fig 3C). This latter subject had complete angiographic occlusion (Fig 3B). One rabbit that had complete tissue membrane covering the device on gross examination was found to have a small neck remnant both pathologically and angiographically. Microscopic examination showed that 3 aneurysms at 1 4 Kwon AJNR 2011 www.ajnr.org

month had completely organized loose connective tissue filling the entire aneurysmal cavity. Organized loose connective and unorganized thrombus both were present and filled the aneurysm cavity in the remaining subject. The Neointimal formation at the aneurysmal neck could be confirmed in 3 subjects. Three-month gross and microscopic examination in 8 rabbits showed a membranous tissue completely covering the device, organized loose connective tissue filling the entire aneurysm cavity, and neointima crossing the neck in all 8 specimens (Fig 2F). Discussion In this study, we described the in vivo preclinical performance of the Luna AES device, designed to be placed in the aneurysmal cavity and to provide flow disruption across the metallic struts from the parent artery to the aneurysm. Using the Luna AES, we noted complete or near-complete cessation of intraaneurysmal flow within minutes after placement in most cases. High rates of complete aneurysm occlusion were noted at 1 and 3 months. The histologic findings showed excellent healing within the aneurysm cavity and along the aneurysm neck in most cases. These data suggest that the Luna AES might be used for occlusion of intracranial saccular aneurysms, both ruptured and unruptured. With the advent of intraluminal flow-diversion devices, the endovascular community has refocused attention away from devices aimed at filling the aneurysm cavity and toward devices that can achieve disruption of flow along the aneurysm neck. 8-12 Unlike current endoluminal flow-diversion devices, the Luna AES does not require the use of dual antiplatelet therapy. Furthermore, at least on the basis of the preclinical work described here, the Luna AES might also achieve immediate or nearly immediate cessation of flow within the aneurysm cavity due to a high degree of neck coverage compared with coiling, allowing its use in ruptured aneurysms. Notwithstanding the promising results from the current study, there remain substantial uncertainties about the use of the Luna AES. The device is not suitable for complex irregular, wide-neck, and fusiform aneurysms. The aneurysms treated in this preclinical study almost certainly were more regular in shape than many human aneurysms; as such, the high rates of complete occlusion may be overstated here in comparison with what may be expected clinically. Precise device sizing and positioning are the most important factors for good results but will require refinement as the device is applied clinically, because the geometry of an aneurysm is a 3D sphere and the morphology and delivery are markedly different from that of coils. Furthermore, strategies for addressing incomplete aneurysm occlusion, either immediate or delayed, may be problematic because coil placement into the lumen of the indwelling Luna AES device will not be feasible. Because this was the initial feasibility trial, it was powered for practical and not statistical considerations; therefore, the number of aneurysms treated was small for drawing a conclusion concerning aneurysm obliteration or parent artery patency rates. In addition, the devices were placed through 5F guiding catheters rather than microcatheters. Further study regarding trackability in a tortuous vasculature through the microcatheter will be needed. Finally, the aneurysm dimensions were relatively small, and the aneurysm necks were relatively narrow, so the use of the Luna AES in large and wideneck aneurysms remains unexplored. Conclusions The Luna AES, an intrasaccular flow-diverting device, provided excellent acute and short- and midterm continuous angiographic and histopathologic aneurysmal occlusion in the rabbit model. Furthermore, no antiplatelet therapy is required. References 1. Gallas S, Pasco A, Cottier JP, et al. A multicenter study of 705 ruptured intracranial aneurysms treated with Guglielmi detachable coils. AJNR Am J Neuroradiol 2005;26:1723 31 2. Molyneux A, Kerr R, Stratton I, et al. International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trial. Lancet 2002;360:1267 74 3. Molyneux A, Kerr R, Yu L, et al, for the International Subarachnoid Aneurysm Trial (ISAT) Collaborative Group. International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusion. Lancet 2005;366:809 17 4. Hayakawa M, Murayama Y, Duckwiler G, et al. Natural history of the neck remnant of a cerebral aneurysm treated with the Guglielmi detachable coil system. J Neurosurg 2000;93:561 68 5. Kole MK, Pelz DM, Kalapos P, et al. Endovascular coil embolization of intracranial aneurysms: important factors related to rates and outcomes of incomplete occlusion. J Neurosurg 2005;102:607 15 6. Byrne J, Sohn M, Molyneux A, et al. Five-year experience in using coil embolization for ruptured intracranial aneurysms: outcomes and incidence of late rebleeding. J Neurosurg 1999;90:656 63 7. Raymond J, Guilbert F, Weill A, et al. Long-term angiographic recurrences after selective endovascular treatment of aneurysms with detachable coils. Stroke 2003;34:1398 403 8. Ahlhelm F, Roth C, Kaufmann R, et al. Treatment of wide-necked intracranial aneurysms with a novel self-expanding two-zonal endovascular stent device. Neuroradiology 2007;49:1023 28 9. Ionita CN, Paciorek AM, Dohatcu A, et al. The asymmetric vascular stent: efficacy in a rabbit aneurysm model. Stroke 2009;40:959 65 10. Kallmes DF, Ding YH, Dai D, et al. A new endoluminal, flow-disrupting device for treatment of saccular aneurysms. Stroke 2007;38:2346 52 11. Kallmes DF, Ding YH, Dai D, et al. A second-generation, endoluminal, flowdisrupting device for treatment of saccular aneurysms. AJNR Am J Neuroradiol 2009;30:1153 58 12. Sadasivan C, Cesar L, Seong J, et al. An original flow-diversion device for the treatment of intracranial aneurysms: evaluation in the rabbit elastase-induced model. Stroke 2009;40:952 58 13. Altes TA, Cloft HJ, Short JG, et al. 1999 ARRS Executive Council Award: creation of saccular aneurysms in the rabbit a model suitable for testing endovascular devices. AJR Am J Roentgenol 2000;174:349 54 14. Ding YH, Dai D, Lewis DA, et al. Intra-venous digital subtraction angiography: an alternative method to intra-arterial digital subtraction angiography for experimental aneurysm imaging. Neuroradiology 2005;47: 792 95 15. Dai D, Ding YH, Lewis DA, et al. A proposed ordinal scale for grading histology in elastase-induced, saccular aneurysms. AJNR Am J Neuroradiol 2006;27:132 38 16. Dai D, Ding YH, Danielson MA, et al. Modified histologic technique for processing metallic coil-bearing tissue. AJNR Am J Neuroradiol 2005;26:1932 36 AJNR Am J Neuroradiol : 2011 www.ajnr.org 5