RM Philosophy Innovation based on clinical evidence.

Similar documents
Case report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis?

TOTAL HIP REPLACEMENT:

Optimum implant geometry

Systematic Review of Clinical Outcome using Titanium Fiber Mesh Porous Ingrowth Surfaces

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter

HOSPITAL "A" (2007) ORTHOPEDIC JOINT IMPLANT COMPONENT MATRIX

Principles of acetabular fixation in primary and revision hip arthroplasty Piotr Wojciechowski, Damian Kusz, Anna WAGNER

Enhancing stability and increasing range of motion. Metasul LDH Large Diameter Head

Klinische und radiologische Ergebnisse einer «isoelastischen» Pfanne

Product Information. *smith&nephew POLARCUP Dual Mobility System

Allofit /Allofit -S Alloclassic Acetabular Cup System

A further enhanced classic. Wagner SL Revision Hip Stem

The Leader in Orthopaedic Innovation

G7 ACETABULAR SYSTEM. beautifully. efficient.

Optimum implant geometry

Featuring. Technology. Product Rationale

Zimmer Segmental System

The information contained in this document is intended for healthcare professionals only.

A NEW APPROACH TO BEARING SURFACES FOR TOTAL HIP ARTHROPLASTY

Active Articulation E1

Understanding Hip Implant Options

Exeter. Designed for Anatomic Restoration. Clinical Evidence Education

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique

Acetabular Cup System. Clinical Summary

Bone Bangalore

Trinity. Advanced Bearing Acetabular System Surgical technique

Stability without compromise. Epsilon Durasul Constrained Insert

Optimizing function Maximizing survivorship Accelerating recovery

SUMMIT and DURALOC. Clinical Summary

PINNACLE Acetabular Cup System

ACETABULAR CUP SURGICAL TECHNIQUE

Optimum implant geometry

Aesculap Plasmafit. Cementless Acetabular Cup System. Aesculap Orthopaedics

Regenerex Porous Titanium Construct. Knees Hips Extremities Cement and Accessories PMI Trauma Technology

Hedrocel trabecular metal monoblock acetabular cups : mid-term results

Index. Gainslen prosthesis 125. Debonding 22-3 Degradation products 40-1 Diffusion theory of adhesive wear 137 Dual energy X-ray absorption 95-6, 98

Arcos Modular Femoral Revision System

CONSENSUS ORTHOPEDICS INC.

Dual Mobility System Surgical technique

COMMERCIAL LEAFLET. Inventor of dual mobility. in Novae. range

ESC. Enhanced Stability Liners. Design Rationale & Surgical Technique

Trabecular Metal Technology The Best Thing Next to Bone

UHMWPE LONGEVITY: INFLUENCES OF THE ORTHOPAEDIC TRIAD

The information contained in this document is intended for healthcare professionals only.

Cementless femoral stem type SF

StelKast Acetabular. Surgical Protocol and Product Specifications. Including ProForm, Provident, Provident Apical Threaded Hole & Systems

Impingement in THA. Georgi I. Wassilew. Orthopaedic Department, Centrum für Muskuloskeletale Chirurgie Univ.-Prof. Dr. med. C.

Duraloc CONSTRAINED LINER

1Acetabular Reaming. 2Shell Sizing and Positioning. Trial Range of Motion. Trabecular Metal Natural Cup System

National Joint Replacement Registry. Lay Summary 2015 Annual Report Hip and Knee Replacement

ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY

Bi-Polar 22.2mm & 28mm System - Operative technique

MicroSeal Total Hip Acetabular System. Like Nothing Else

1.1 Ceramic on Ceramic Bearings Used with Proximal Modular Stems in THA K. J. Keggi, J. M. Keggi, R. E. Kennon and T. McTighe

Zimmer TM. Continuum Acetabular System. Bringing together proven technologies.

Dual Mobility System Evaluation surgical technique

Hip Product Brochure

Trusted technology. Trusted performance. Supporting healthcare professionals

Dual Mobility Cups. Kris Govaers, MD, PhD Dendermonde Belgium

Trabecular Metal Natural Cup System

Poor mid-term results of total hip arthroplasty with use of a Hylamer liner

CORAIL HIP SYSTEM DESIGN RATIONALE

SSSR HIP PROSTHESIS MODELS AND MATERIALS SURGICAL TECHNIQUES APPROACHES. Patrick Zingg Department of Orthopaedics University of Zurich, Balgrist

DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN USA Tel: +1 (800) Fax: +1 (574)

The science of simplicity

Revision systems. Catalogue - revision implants ARTHROPLASTY

Hard Implants. Lecture #13

Scan Bi-Polar 22/28. Operative Technique

EARLY CLINICAL RESULTS OF PRIMARY CEMENTLESS TOTAL KNEE ARTHROPLASTY

Section of total knee replacement. Total Knee Replacement System. Knieendoprothesen System. Système de prothèse totale de genou

Surface Roughness of Femoral Head Prostheses After Dislocation

MARATHON Cross-Linked Polyethylene

28 Surgical Technique

PINNACLE REVISION CUP SYSTEM

Clinical and radiological results of the stemmed Mc Minn cup in hip revision surgery

Revision Total Hip Arthroplasty Using an Extensively Porous Coated Femoral Stem

Trabecular Metal Acetabular Revision System Buttress and Shim Augments Surgical Technique

R3think your options. For US distribution only.

Reaching new heights. Comprehensive. Efficient. Simple.

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

Document No Rev. B Pg. 1 of 5 Approvals / Date Title: INSTRUCTIONS FOR USE DJO SURGICAL MODULAR REVISION HIP SYSTEM AND ACETABULAR CAGE

simplicity THE SCIENCE OF DESIGN RATIONALE

CONSENSUS ORTHOPEDICS INC. UNISYN HIP SYSTEM

PROCOTYL E Acetabular Cup System. Modular to Fit Patient s Anatomy. Versatile for Revisions.

FIXATION FIRST WEAR REDUCTION OXIDATIVE STABILITY MECHANICAL INTEGRITY PROVEN TECHNOLOGY

Comprehensive Reverse Shoulder System

National Joint Replacement Registry. Metal and Ceramic Bearing Surface in Total Conventional Hip Arthroplasty

Hip Implants. Hip Implants. 6 Your partner for implants and trauma products. Euromed Implants GmbH General Catalogue

RECOVERY. P r o t r u s i o

Product Portfolio. Consensus Knee Systems. Consensus Hip Systems

UNCEMENTED HIP ARTHROPLASTY IN PRIMARY AND REVISION SURGERY Patterns of bone remodelling and options to influence periprosthetic bone loss

The bi-metric XR series of Hip implants blends biomet s proven philosophy and tradition with Advanced technology. porous primary hip series

OPTIMIZATION OF SKELETAL HIP IMPLANT CROSS-SECTIONS

THE PERSONALIZED KNEE

Design Rationale. ECHELON Primary Hip System

Triathlon Tritanium Knee System

Progeny Hip Stem. Surgical Protocol and Product Specifications

Versatility in a proven design. Trilogy Acetabular System

Transcription:

RM Philosophy Innovation based on clinical evidence

RM Philosophy Innovation based on clinical evidence Design 1973 RM Classic Cup First uncoated RM Classic Cup out of Polyacetal was inserted by E. Morscher in 1973. First uncoated RM Classic Cup out of UHMWPE was implanted in 1975.

The Idea - Isoelasticity the main problem is the difference in bony elasticity encountered between various parts of the acetabulum Bombelli et. al. Journal of the Roval Society of Medicine (1982) Robert Mathys Senior developed the idea of isoelasticity Because of the poor wear characteristics of POM (Polyoxymethylene), Mathys preferred to use high density polyethylene (UHMWPE) Surface of each cup bears shallow circular grooves to allow bone ingrowth Two pegs to secure a firm anchoring and resist rotational forces After extensive tests in animals, the first RM cementless hip prosthesis was inserted by E. Morscher in 1973 In 1967 Robert Mathys conceived the idea of an isoelastic prosthesis made of plastic, which would anchor into the bone without cement

RM Philosophy Innovation based on clinical evidence Design Coating 1973 1983 RM Classic Cup Since the first implantation in 1973 more than 271 000 RM Classic Cups were implanted

The Beginning - RM Classic Cup

10 A rating for the RM Classic Cup The RM Classic Cup is listed in the ODEP (Orthopaedic Data Evaluation Panel) with a 10A NICE (National Institute for Health and Clinical Excellence) rating in the United Kingdom. Supplier Product Cup/Stem Fixation Modularity Date of first clinical use Modifications Number of separate datasets submitted ODEP View Year rated Mathys RM CUP TiCP COATED Cup Cementless Monobloc 1983 Yes 14 10A 2011 In total only 12* uncemented acetabular cups currently have a 10A rating. RM Classic Cup is one of them! *Source: http://www.supplychain.nhs.uk/odep/ (accessed on 07.08.2013)

10 A rating for uncemented cup *Source: http://www.supplychain.nhs.uk/odep/ (accessed on 30.01.2014)

10 A rating in UK today

10 A rating for the RM Classic Cup & for two more Beside the RM Classic Cup two more Mathys implants reached this rating Supplier Product Cup/Stem Fixation Modularity Date of first clinical use Modifications Number of separate datasets submitted ODEP View Year rated Mathys RM CUP TiCP COATED Cup Cementless Monobloc 1983 Yes 14 10A 2011 Mathys CCA (Muller straight stem) Stem Cemented Modular 1996 No 8 10A 2013 Since the first implantation in 1985 more than 350 000 RM Classic Cup were implanted Mathys CCB (Muller cup) Cup Cemented Monobloc 1996 No 6 10A 2013

Why registry data as reference? Worldwide joint arthroplasty registers are instrumental to screen for complications or implant failures Labek et. al. J Arthroplasty (2013) Registry data are.. provided by the registries official available of high evidence of high acceptance including survival & revision rates

Survival rate for uncemented cup Uncemented cups were used at considerably lower ages uncemented cups: mean age 57.3±10.4 years cemented cups: mean age 70.7±9.5 years more often in men uncemented cups: 51.4%, cemented cups: 39.2% less frequently in secondary osteoarthritis uncemented cups: 17.4%, cemented cups: 19.9% Conclusion: Uncemented cups have a somewhat reduced risk of revision for loosening/osteolysis up to an age of 69 years but are associated with other problems that lead to revision, for which reason the total revision risk shows no significant difference. Annual Report 2010, Swedish Hip Arthroplasty Rergister

Survival rate for uncemented cup Registry data We only consider the average survival rate for uncemented cups irrespective of cause

Survival rate for RM Classic Cup Study data Glossar [2]: Blencke et.al. (2004) Orthopädische Praxis, 40(9):500-506 [3]: John T et.al. (2009) EFORT Congress 3-6 June 2009, Vienna [4; 4]: Ihle M et.al. (2008) J Bone Joint Surg Br, 90(10):1284-90 [5]: Annual Report (2010) Swedish Hip Arthroplasty Register At 19.8 years the survival rate of the RM Classic Cup for aseptic loosening is at 94.4% which is an excellent outcome

Medium-term results after the implantation of coated RM cups (12-year results) Blencke BA (2005) Ortopaedics Today International Follow up of 307 implantations in year 1990 Mean age of the patients was 67.3 years Between 1990 and 2002, revision of implant of 13 patients 3 isolated cup revisions, 3 isolated stem revisions, 6 complete prosthetic revisions, explanation of 1 prosthesis because of a suspected infection and re-implantation after 6 months. 11 of 224 patients required a cup revision within 12 years. All prosthetic cup revisions performed in the hospital were caused by aseptic indications Mean survival rate after 12 years for the RM Classic Cup irrespective of cause: 96.4% The implantation of coated RM cups has provided good medium and long-term results and has exhibited a durable fixation after a minimum follow-up of 12 years

The uncemented titanium coated monobloc Robert Mathys acetabular component. A retrospective study over 15 years John T. et.al.(2009), EFORT Congress 3-6 June 2009, Vienna 1876 RM Classic Cups between January 1,1988 and December 31, 2001 451 patients had died unrelated to the operation during follow up Lost of follow up were 65 patients (69 Cups) and 34 patients (48 cups) had to be revised. Reason for revision 34 aseptic loosening, 8 infection, 2 dislocation, 2 malposition, 2 periprosthetic fractures Cumulative survival rate of the RM Classic Cup is 98.2 % @ 5 year 97.5% @ 10 years 96.9% @ 15 years The RM Classic Cup has been shown to function well at up to 15 years post implantation. Its success may in part be due to the one-piece design.

The results of the titanium-coated RM acetabular component at 20 years: a longterm follow-up of an uncemented primary total hip replacement Ihle M., Mai S., Pfluger D., Siebert W. (2008); J Bone Joint Surg Br.90(10):1284-90 93 consecutive primary THRs between January 1986 and July 1989 Mean age of the patients 52 years (28 to 81) None were lost to follow-up At the last follow up 23 patients (26 hips) had died 14 acetabular component revisions were carried out after a mean of 12.3 years 7 for osteolysis, 5 for loosening, 2 for infection Mean survival rate for the RM Classic Cup irresepective of cause: 82.7% Mean survival rate for the RM Classic Cup for aseptic loosening: 94.4% The RM concept of a monobloc acetabular component is unique. Backside wear, which occurs between a hard metal shell and the polyethylene liner, can be avoided

The design evolution - RM Pressfit Cup

RM Philosophy Innovation based on clinical evidence Design Coating Design 1973 1983 2002 RM Classic Cup RM Pressfit Cup

RM Pressfit Cup - Design concept Innovation based on excellent long-term results of RM Classic Cup UHMWPE-body to generate press-fit Use same parameters and coating as from RM Classic Cup Leaving the pegs away No drilling Short surgical technique Easy instrumentation Adaptation of the design 1.6 mm equatorial pressfit No circular grooves for higher primary bone/implant contact surface

Registry data RM Pressfit Cup Lower revision rate of RM Pressfit Cup compared to the average of all cups documented in the registry *The New Zealand Joint Registry Januar 1999 to December 2010

5 A rating for the RM Pressfit Cup The RM Pressfit Cup is listed in the ODEP (Orthopaedic Data Evaluation Panel) with a 5A NICE (National Institute for Health and Clinical Excellence) rating in the United Kingdom. Supplier Product Cup/Stem Fixation Modularity Date of first clinical use Modifications Number of separate datasets submitted ODEP View Year rated Mathys RM Pressfit Cup Cup Cementless Monobloc 2002 Yes 7 5A 2013

Osteolysis Osteolysis is one of the major failure mode of cemented and uncemented acetabular fixation [1] It is a consequence of the biological reaction of bone to ultra-high-molecular-weight polyethylene (UHMWPE) wear and metallic debris [1] The amount of UHMWPE wear is negatively correlated with the long-term survival of both cup and stem [2] [1] Macheras G, Kateros K, Kostakos A, et al. Eight- to ten-year clinical and radiographic outcome of a porous tantalum monobloc acetabular component. J Arthroplasty 2009;24(5):705. [2] Ilchmann T, Markovic L, Joshi A, et al. Migration and wear of long-term successful Charnley total hip replacements. J Bone Joint Surg Br 1998; 80-B(3):377. Therefore, knowledge of wear over time is an important indicator of the risk of early loosening

Osteolysis Courtesy Dr Ilchmann RM cup: Low wear, no holes in the back, good osteointegration = Less acetabular osteolysis

Osteolysis & wear rate in general & RM Cups Osteolysis is infrequent when wear rates are below 0.1 mm/y and virtually absent below 0.05mm/y Dumbleton et al J Arthroplasty (2002) RM Pressfit Cup RM Classic Cup metalback pressfit cup cemented all poly cups Ti-backed pressfit cups Ceramic-Ceramic (< 45 ) Ceramic-Ceramic (> 45 ) Wyss T et al, J Arthroplasty (2013) Lemaire, Maîtrise Orthopédique 158 (2), (2006) Lemaire, Maîtrise Orthopédique 158 (2), (2006) McCombe, JBJS (Br) 86-B, (2004) McCombe, JBJS (Br) 86-B, (2004) Brandt, Proc Inst Mech Eng H, 227(8), (2013) Brandt, Proc Inst Mech Eng H, 227(8), (2013) 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 Reported wear of RM Classic Cup and RM Pressfit Cup are between 0.02 and 0.09 mm/y low risk of osteolysis

Stress shielding Müller, J Orthop Res 27:176 182, (2009) Cemented cups especially prevent the loss of cancellous bone of the acetabulum while also cortical BD loss was significantly lower compared to the press-fit component.

Stress shielding Density (g/cm3) E modulus (N/mm2) Tensile strength (N/mm2) Bone 0.2 2 500 6000 10 150 Bone cement 1.17 3000 47 UHMWPE 0.94 1000 35 vitamys 0.94 800 37 Titanium 4.5 105 000 400 Mechanical properties of polyethylene and bone cement Mechanical properties of bone We expect the RM cup philosphy to behave as a cemented cup in terms of stress shielding

Osteolysis in long term follow up Between 13.7 and 15.7 years after initial operation a notable number of revisions of well integrated and stable cups due to osteolysis, were reported Most common reason was polyethylene wear All heads were 32mm in diameter 80 femoral heads were made of ceramic 13 femoral heads were made of CoCrMo alloy Therefore, reduction in wear the future challenge for uncemented hip prosthesis

RM Philosophy Innovation based on clinical evidence Design Coating Design Material 1973 1983 2002 2009 RM Classic Cup A promising solution to future challenge of wear reduction is the RM Pressfit vitamys RM Pressfit Cup

A promising solution to future challenge of wear reduction is the RM Pressfit vitamys

The future - RM Pressfit vitamys Cup

Cross-linking of UHMWPE [ ultra high molecular weight polyethylene ] Need to generate free radicals to enable cross-linking Free radicals may react with oxygen Oxidation irreversible scission of molecular chains, embrittlement etc. How to reduce the free radicals? How to prevent oxidation?

Why chose vitamin E (α-tocopherol)? Protects cell walls from oxidation during O 2 transport through these walls Ingredient of anti-ageing crèmes, food packaging Maximum daily amount: 400 mg Vitamin E reacts with oxygen & slows down the ageing process

Vitamin E meets RM Pressfit The HXLPE with highest level of mechanical properties (Type 1 according to ISO 5834-2) Allowing articulations up to 36mm from size 52 Vitamin E reacts with oxygen and slows down the ageing process Modulus of elasticity of the cup is 800N/mm 2 ~50mg Vitamin E in a RM Pressfit vitamiys cup Improving wear performance while maintaining mechanical properties

Advantages of vitamys Accelerated ageing through increased temperatures and oxygen content is used to simulate oxidation and ageing over many years of shelf storage 60 days accelerated ageing under O 2 (70 C, 5bar) correlates to 40 years in vivo. Lerf R, Zurbrügg D, Delfosse D, Biomaterials 31 (2010) 3643 3648 The in vitro testing of vitamys proved to be long-term oxidation and ageing resistant

Clinical results and ongoing studies of vitamys Wear rates of standard UHMWPE is strongly affected by ageing (oxidation) 80 % Better wear resistance with vitamys Wear rate of vitamys is 80% lower than the standard UHMWPE Wear rate of vitamys remained at a constant level Wear rate remain at a constant level using different head materials (CoCr / ceramic) and diameters (28 mm, 36 mm) Beck M, et al. in Karl Knahr (Ed.), Total Hip Arthroplasty, 2012 EFORT Increased wear resistance should theoretically lead to less osteolysis and thus to better long-term outcomes

Clinical results and ongoing studies of vitamys Wear rate of vitamys is therefore predicted to remain at the same low level over its lifetime inside patients 2 year in vivo results confirm this prediction!

UHMWPE

Take Home Message RM Philosophy Innovation based on clinical evidence Coating Design Material The Beginning - RM Classic Cup Two pegs to secure a firm anchoring and resist rotational forces Circular grooves to allow bone ingrowth Extraordinary long term results Backside wear can be avoided The design evolution - RM Pressfit Cup 1.6 mm equatorial pressfit No circular grooves for higher primary bone/implant contact surface Lower revision rate compared to the average of all cups Wear rate 0.09mm/y after 5 years The future - RM Pressfit vitamys Cup Wear rate of vitamys is 80 % lower than the standard UHMWPE In vitro testing proved to be longterm oxidation and ageing resistant Wear rate predicted to remain at the same low level over its lifetime

Mathys optimys hip stem