A randomized clinical trial to compare three methods of orthodontic space closure

Similar documents
The effect of environmental factors on elastomeric chain and nickel titanium coil springs

The management of impacted

Experience with Contemporary Tip-Edge plus Technique A Case Report.

The Tip-Edge appliance and

ORTHOdontics SLIDING MECHANICS

Use of a Tip-Edge Stage-1 Wire to Enhance Vertical Control During Straight Wire Treatment: Two Case Reports

Forsus Class II Correctors as an Effective and Efficient Form of Anchorage in Extraction Cases

HYCON DEVICE: A PRECISE AND CONTROLLED METHOD OF SPACE CLOSURE A CASE REPORT

Plus Combines Traditional Twin Bracket Treatment With Self-Ligation Convenience

The Comparison of Space Closure Rate between Conventional and Passive Self-ligating System Using Elastomeric Chain in Maxilla

A Novel Method of Altering the Buccal Segment Relationship

A randomized clinical trial to compare the Goshgarian and Nance palatal arch

INDICATIONS. Fixed Appliances are indicated when precise tooth movements are required

Dual Force Cuspid Retractor

With judicious treatment planning, the clinical

From Plan B to Plan A : Using Forsus Class II Correctors as a Regular Mode of Treatment

Space Closure Biomechanics Applied Using The MBT System Technique

The effectiveness of laceback ligatures: A randomized controlled clinical trial

A New Low-Friction Ligation System

Is nickel titanium superior to multistranded stainless steel wire in aligning crowded lower anteriors? A comparative in-vivo study.

Archwires & Accessories

wiirre e a a n n d d w wiirre e ffo orrms ms

IN VIVO FORCE DECAY OF NITI CLOSED COIL SPRINGS. Crystal R. Cox, DDS. Chapel Hill 2012

An Effectiv Rapid Molar Derotation: Keles K

Integrative Orthodontics with the Ribbon Arch By Larry W. White, D.D.S., M.S.D.

Simply Great Wire! Great prices.

The 20/20 Molar Tube. Ronald M. Roncone, D.D.S., M.S.

SE NiTi Heat Activated NiTi Ultra T Heat Activated NiTi Stainless Steel Beta Titanium. Ultra T Archwires

(12) Patent Application Publication (10) Pub. No.: US 2005/ A1

6. Timing for orthodontic force

The effect of Gable angle size and spring activation distance of 0.016x0.022 NiTi and TMA sectional T-loop towards force, moment y.

Mx1 to NA = 34 & 10 mm. Md1 to NB = 21 & 3 mm.

THE USE OF VACCUM FORM RETAINERS FOR RELAPSE CORRECTION

Evaluation of space closure rate during canine retraction with nickel titanium closed coil spring and elastomeric chain.

Delta Force. Bracket System. Putting you in the driver s seat for ultimate control

A clinical comparison of three aligning archwires in terms of alignment efficiency: A prospective clinical trial

We Give Back. Reduce Emergency Visits! ATTACHMENTS. No More Poking Archwires! Crimpable Mini Stops. Tooth Tone Crimpable Mini Stops

An Innovative Treatment Approach with Atypical Orthodontic Extraction Pattern in Bimaxillary Protrusion Case

Controlled Space Closure with a Statically Determinate Retraction System

3D CONTROL HAS ARRIVED

The Science Behind The System Clinical Abstracts, Volume 2

MemRx Orthodontic Appliances

TOL

CLASS II CORRECTION SIMPLIFIED

Premium Heat Activated Arch Wire

New Class of Appliance

Aesthetic Brackets and Accessories

Changes in Lip, Cheek, and Tongue Pressures After Rapid Maxillary Expansion Using a Diaphragm Pressure Transducer

essentialstm cutting your consumable costs brackets tubes wires springs instruments T:

Dental Materials Journal 2015; 34(3): Keisuke TOCHIGI, Souichiro ODA and Kazuhito ARAI INTRODUCTION

Crowding and protrusion treated by unusual extractions

GAC Archwire Collection

System Orthodontic Treatment Program By Dr. Richard McLaughlin, Dr. John Bennett and Dr. Hugo Trevisi

Sliding mechanics in an extraction case treated with 3M Clarity ADVANCED Ceramic Brackets and the 3M MBT Appliance System.

ANTERIOR AND CANINE RETRACTION: BIOMECHANIC CONSIDERATIONS. Part One

Victory Series Active Self-Ligating Brackets. Reliable. and. Effective

Treatment of Class II, Division 2 Malocclusion with Miniscrew Supported En-Masse Retraction: Is Deepbite Really an Obstacle for Extraction Treatment?

Keeping all these knowledge in mind I will show you 3 cases treated with the Forsus appliance.

The Effect of Using Self-ligating Brackets on Maxillary Canine Retraction: A Split-mouth Design Randomized Controlled Trial

Non Extraction philosophy: Distalization using Jone s Jig appliance- a case report

ARCHWIRE. An extensive selection of high quality wire types and arch forms WIRE PRODUCTS. Wires. TruFlex Nickel Titanium Archwire. TruFlex.

BRACKET CHOICES SYSTEM CHOICES. Empower 2 reconvertible molar tubes provide versatility without compromise.

AL-AZHAR. Dental Journal. Print ISSN Online ISSN ADJ-for Girls, Vol. 5, No. 1, January (2018) PP. 9:14

Gentle-Jumper- Non-compliance Class II corrector

Canine Extrusion Technique with SmartClip Self-Ligating Brackets

Surgically assisted rapid palatal expansion (SARPE) prior to combined Le Fort I and sagittal osteotomies: A case report

Correction of Crowding using Conservative Treatment Approach

SnapLink Re-Convertible Tube

ISW for the treatment of moderate crowding dentition with unilateral second molar impaction

Measurements of the torque moment in various archwire bracket ligation combinations

The validation of the Peer Assessment Rating index for malocclusion severity and treatment difficulty

2007 JCO, Inc. May not be distributed without permission.

A New Fixed Interarch Device for Class II Correction

The Loading And Unloading Properties Of Various Arch Wires As A Function Of Cross Sectional Dimension And Inter Bracket Span Width System

Crowded Class II Division 2 Malocclusion

UNILATERAL UPPER MOLAR DISTALIZATION IN A SEVERE CASE OF CLASS II MALOCCLUSION. CASE PRESENTATION. 1*

Self-ligating versus Invisalign: analysis of dento-alveolar effects

Quality. Elegance. Innovation.

Effects of a three-dimensional bimetric maxillary distalizing arch

Orthodontic Treatment Using The Dental VTO And MBT System

Treatment of a Patient with Class I Malocclusion and Severe Tooth Crowding Using Invisalign and Fixed Appliances

Arch dimensional changes following orthodontic treatment with extraction of four first premolars

Treatment of Class II, Division 2 Malocclusion in Adults: Biomechanical Considerations FLAVIO URIBE, DDS, MDS RAVINDRA NANDA, BDS, MDS, PHD

Intraoral molar-distalization appliances that

The Effectiveness of the Uprighting Spring to Support an Anchorage of Posterior Teeth during Canine Retraction Chatchalit Poolsak

THE MBT VERSATILE+ APPLIANCE SYSTEM

Incognito. Appliance System goes Digital. 3Unitek. Now in 3D. The Incognito Appliance System Digital Setup with 3D PDF Documentation

Instability of tooth alignment and occlusal relationships

Anterior Open Bite Correction with Invisalign Anterior Extrusion and Posterior Intrusion.

Molar anchorage loss has been shown to occur

Indian Journal of Basic and Applied Medical Research; June 2014: Vol.-3, Issue- 3, P

A Collection of High Quality Orthodontic Instruments

Outline the significance of the pre-adjusted Edgewise appliance system and useful bracket variations in orthodontics

Perception of pain and discomfort from three different types of orthodontic separators

The Tip-Edge Concept: Eliminating Unnecessary Anchorage Strain

rocky mountain orthodontics functionaleducation

Third-Order Torque and Self-Ligating Orthodontic Bracket Type Effects on Sliding Friction

Force Decay Associated With Coloured Elastomeric Chains; an Ex Vivo Investigation

LINGUAL STRAIGHTWIRE BRACKET SYSTEM Designed with Drs. Kyoto Takemoto and Giuseppe Scuzzo

A THESIS SUBMITTED TO THE FACULTY OF THE GRADUATE SCHOOL OF THE UNIVERSITY OF MINNESOTA BY

Transcription:

Journal of Orthodontics, Vol. 29, 2002, 31 36 SCIENTIFIC SECTION A randomized clinical trial to compare three methods of orthodontic space closure V. Dixon, M. J. F. Read, K. D. O Brien, H. V. Worthington and N. A. Mandall University Dental Hospital of Manchester, UK Abstract Index words: Active ligatures, orthodontic space closure, nickel titanium springs, powerchain, rate of tooth movement, randomized clinical trial. Aim To compare the rates of orthodontic space closure for: Active ligatures, polyurethane powerchain (Rocky Mountain Orthodontics, RMO Europe, Parc d Innovation, Rue Geiler de Kaysersberg, 67400 Illkirch-Graffenstaden, Strasbourg, France) and nickel titanium springs. Sample Patients entering the space closure phase of fixed orthodontic treatment attending six orthodontic providers. Twelve patients received active ligatures (48 quadrants), 10 patients received powerchain (40 quadrants) and 11 patients, nickel-titanium springs (44 quadrants). Method Patients were randomly allocated for treatment with active ligatures, powerchain or nickel titanium springs. Upper and lower study models were collected at the start of space closure (T o ) and 4 months later (T 1 ). We recorded whether the patient wore Class II or Class III elastics. Space present in all four quadrants was measured, by a calibrated examiner, using Vernier callipers at T o and T 1. The rate of space closure, in millimetres per month (4 weeks) and a 4-monthly rate, was then calculated. Examiner reliability was assessed at least 2 weeks later. Results Mean rates of space closure were 0.35 mm/month for active ligatures, 0.58 mm/month for powerchain, and 0.81 mm/month for NiTi springs. No statistically significant differences were found between any methods with the exception of NiTi springs showing more rapid space closure than active ligatures (P 0.05). There was no effect of inter-arch elastics on rate of space closure. Conclusions NiTi springs gave the most rapid rate of space closure and may be considered the treatment of choice. However, powerchain provides a cheaper treatment option that is as effective. The use of inter-arch elastics does not appear to influence rate of space closure. Received 20 March 2001; accepted 28 June 2001. Introduction In this study, we set out to evaluate the effectiveness of three space closure methods: polyurethane powerchain, active ligatures, and nickel titanium (NiTi) springs for orthodontic space closure. During orthodontic treatment involving extraction of teeth, there is often a need to close residual space. When space-closing sliding mechanics are used with the straight wire appliance, a force of between 100 200 g has been recommended by using elastic or wire springs. 1 Currently, there are several commonly used methods of applying this force: these are elastic modules, 2 elastic chain and NiTi springs. However, the potential disadvantage of elastic chain or active modules is the significant force decay over time. 3 6 As a result, NiTi springs are an alternative in widespread use. NiTi springs have the reported advantage of giving significantly quicker and more consistent rates of space closure, 2,7,8 but are relatively expensive to use. In contrast, active ligatures are cheap and arguably easier for the patient to keep clean. Since the comparative clinical performance of powerchain, active ligatures and NiTi springs has not previously been reported, the aim of the study was to compare the effectiveness of these three methods of orthodontic space closure. Sample We calculated the sample size for each group as 11 patients, based on an alpha significance level of 0.05 and Address for correspondence: Dr N. A. Mandall, Orthodontic Department, University Dental Hospital of Manchester, Higher Cambridge Street, Manchester M15 6FH, UK. E-mail: Nicky@fsi.den.man.ac.uk

32 V. Dixon et al. Scientific Section JO March 2002 a beta of 0.1. This gave a 90 per cent power to detect a difference of 3 mm ( 2 mm) of space closure, per 4-month time period, in each quadrant. A 4-monthly rate was used as this was judged to be an approximate average of the time taken for space closure with straightwire mechanics. A difference of 3 mm space closure in this time was considered clinically significant. The sample was obtained from patients attending for orthodontic treatment at the University Dental Hospital of Manchester, Royal Bolton Hospital, Booth Hall Childrens Hospital, and three specialist orthodontic practices. We applied the following inclusion criteria: Patient 10 18 years old at start of treatment A premolar extraction in each quadrant (no other extractions). Upper and lower pre-adjusted edgewise appliance (Roth prescription) Upper and lower 0.019 0.025-inch stainless steel working archwire in place for at least 4 weeks. Informed written consent was obtained from the patient and, where appropriate, the parent. Random allocation method Randomization was completed by throwing an unweighted di, where 1,2 active ligatures, 3,4 powerchain, and 5,6 NiTi springs. A restricted randomization method was used in blocks of 12 to ensure that equal numbers of patients were allocated to each of the three treatment groups. The author then concealed the random allocation in envelopes labelled with the study identification number and held them in a central place. When the patient was registered, the operator telephoned the study centre and a research assistant revealed the space closure method to which the patient (the unit of randomization) was allocated. In this way, the clinician and the patient were blind to the treatment allocation until the patient was registered and the treatment was due to start. During the trial, the operator could not be blind to the method of space closure, however, the examiner carrying out the model outcome measurements was blind until all the data were recorded and the code then broken. Interventions and their timing The planned interventions were rate of space closure over a 1- and 4- month time period using active ligatures, powerchain, or NiTi springs. All patients were treated identically apart from the named interventions. If the clinician wished to use Class II or Class III elastics, they did so and this was recorded and taken into account in the statistical analysis. Outcome measures The outcome measure we assessed in the trial was rate of space closure in millimetres per month (4 weeks) in all four quadrants. A 4-monthly rate of space closure was additionally calculated since this was the unit of time used in the sample size calculation. Appliance design and data collection At the end of levelling and aligning, upper and lower 0.019 0.025-inch stainless steel posted working archwires were placed. The patient was recalled after at least 4 weeks to ensure that the archwires were passive, by sliding the archwire through the bracket slots. Active ligatures Active ligatures were constructed from one grey elastic module and a long ligature. The elastic module was placed round the hook on the first molar band and the metal ligature tied to the hook on the posted archwire, stretching the elastic module twice its resting length. The active ligatures were replaced at each visit. Powerchain Narrow spaced polyurethane powerchain was placed from the first molar hook to the hook on the posted archwire. The powerchain was stretched to approximately twice its resting length and changed at each subsequent visit. NiTi springs NiTi springs (GAC Sentalloy), with 200 g force level, were used in this study and attached in the way described for active ligatures. It would have also been possible to use 150 g springs as these have been shown to be equally effective. 8 The springs were not stretched to more than 9 mm as suggested by Manhartsburger and Seidenbusch, 9 and if they were too small, a short ligature wire was used to attach the spring to the archwire hook. The NiTi springs were not replaced during treatment but were activated as necessary.

JO March 2002 Scientific Section Orthodontic space closure 33 Patient records and stopping rules When the working archwires had been in place at least 4 weeks, the operator removed them, and took upper and lower alginate impressions (T o ), then replaced and tied in with steel ligatures. They then started space closing mechanics. After 4 months (T 1 ) or earlier if space closure was complete, upper and lower alginate impressions were repeated. The patients age at start of space closure and whether they had inter-arch elastics was also recorded. There were no stopping rules identified for this trial as all methods of space closure are in routine use and no special problems with any method were foreseen. Measurement method Vernier callipers were used to measure the maximum distance between the cusp tip of the canine to the buccal groove of the first permanent molar all four quadrants at T o and T 1. Space between premolar and canine contact points was not measured because in many cases, the space at the end of 4 months was too small to be able to fit the Vernier callipers between the contact points. A rate of space closure in millimetres per month and per 4 months for each quadrant, and overall for each patient, was then calculated. models were measured in a random order so that the same patient s start and finish models were not measured consecutively. Random error was addressed by taking each space measurement three times and calculating an average. The error associated with the alginate impression technique and model preparation has been investigated by O Brien et al. 10 and this technique has been shown to have a 97 per cent coefficient of reliability. Examiner calibration and reliability Examiner calibration with Vernier callipers was completed using four metal calibration cubes with different known heights, widths, and lengths. Reliability of the measurements was assessed by re-measuring all the study models at least 1 week later. Statistics We checked the data for normality and produced simple summary statistics. Mean monthly and 4-monthly rates of space closure were compared across the three treatment groups using a two-way ANOVA to take into account the effects of inter-arch elastic wear. Examiner calibration and reliability were assessed using t-tests. Method error Systematic error was reduced by ensuring that the examiner was blind to the treatment group when the model measurements were made. The examiner was also blind (as much as was possible) to whether the model was from the start or after 4 months of space closure. All Results A trial profile for the registered patients is shown in Figure 1. This shows that for 36 patients initially registered, the final sample size for data analysis was 33. Three patients were not included in the data analysis since they were lost to follow-up. Active ligatures Power chain NiTi springs Received standard Received standard Received standard intervention n 12 intervention n 12 intervention n 12 Followed up n 12 Followed up n 10 Followed up n 11 Withdrawn n 0 Withdrawn n 2 Withdrawn n 1 Intervention ineffective n 0 Intervention ineffective n 0 Intervention ineffective n 0 Lost to follow-up n 0 Lost to follow-up n 2 Lost to follow-up n 1 Other n 0 Other n 0 Other n 0 Completed trial n 12 Completed trial n 10 Completed trial n 11 Fig. 1 Profile of randomized clinical trial to compare active ligatures, powerchain, and NiTi springs for orthodontic space closure. Registered or eligible patients n 36; not randomized n 0; randomization n 36.

34 V. Dixon et al. Scientific Section JO March 2002 Table 1 Mean monthly and 4-monthly rates of space closure for active ligatures, powerchain and NiTi springs Active ligatures Powerchain NiTi springs (48 quadrants) (40 quadrants) (44 quadrants) Mean monthly rate (SD) 0.35 mm (0.23 mm) 0.58 mm (0.30 mm) 0.81 mm (0.51 mm) Mean 4-monthly rate (SD) 1.40 mm (0.91 mm) 2.33 mm (1.18 mm) 3.23 mm (2.02 mm) Number of quadrants (%) where space 18 (38%) 12 (30%) 14 (32%) closure was complete at 4 months The mean patient age at the start of the trial was 15 years 6 months (SD 2 years 5 months), and the sample consisted of 23 girls and 10 boys. The mean monthly (4- weekly) space closure rate and 4-month space closure rates are shown in Table 1. Examiner calibration and reliability The examiner (Victoria Dixon) was calibrated for the use of Vernier callipers and the results are shown in Table 2. There was no statistically significant difference between the examiner scores and the gold standard measurements for the calibration blocks (P 0.36). Examiner reliability was similarly high with an intraclass correlation coefficient of 0.99. Comparison of rates of space closure between treatment groups Table 3 includes the comparison of data for monthly rates of space closure among active ligatures, powerchain and nickel-titanium springs. The only statistically significant difference detected was the rate of space closure between NiTi springs and active ligatures (P 0.05). This was despite the number of quadrants with space completely closed being similar among all groups. There was no effect or interaction for the use of Class II or Class III elastics on the rate of space closure for any of the methods. Discussion This randomized clinical trial has suggested that not all orthodontic space closure methods are equally efficient. Although NiTi springs appear to offer the most rapid space closure, powerchain appears to be just as useful. Nickel titanium springs close space more rapidly than active ligatures The results of our study are in agreement with previously published literature, which suggests that NiTi springs Table 2 Examiner calibration for the use of Vernier callipers. Mean (SD) SE P value Examiner 19.70 (14.47) 4.18 0.36 Gold standard 19.70 (14.51) 4.19 give more rapid and reliable space closure than active ligatures. 2,7 However, these other studies used slightly different methodology; Samuels et al. 2 used a split mouth design and many of the patients had single arch fixed appliances. We did not choose this design to eliminate the possibility of one type of space closure affecting the comparison method across the arch. In another investigation, Sonis 7 used NiTi springs to retract canines rather than space close in the buccal segments. This finding may seem surprising, at first, since Nattrass et al. 11 showed initial forces obtained by clinicians were 3.05 N for active ligatures and 1.5 N for NiTi springs. The increased efficiency of NiTi springs is, therefore, unlikely to be caused by the initial force exerted, but rather by the duration of the force as suggested by Proffitt s equilibrium theory. 12,13 It is also possible that the higher initial force with active ligatures is at a level that is counterproductive. It is more probable that it is the more continuous force from the superelastic NiTi springs, 14 which explains the more rapid rates of space closure obtained by this method. But are the results of this study clinically significant? In interpreting the results of this research, it is necessary for the clinician to consider whether any of the results are clinically significant. In this respect, it is debatable whether the differences reported in monthly rates are clinically significant. Even the differences in mean total space closed over a 4-month period are only in the order of 1 2 mm. However, although the difference in space closed between groups may not be large, the case of whether the patient has completed space closure by 4 months is

JO March 2002 Scientific Section Orthodontic space closure 35 Table 3 Two-way ANOVA* to compare the monthly space closure rates for active ligatures, powerchain, and NiTi springs. Sum of squares Df Mean square F ratio P value Space closure group 0.97 2 0.48 3.65 0.040 Inter-arch elastics 0.13 2 6.71 10-2 0.51 0.61 Group elastics 0.33 2 0.17 1.25 0.30 Comparison of groups with Mean SE P value 95% confidence Bonferroni correction difference limits Active ligatures vs powerchain 0.23 0.16 0.45 0.63 0.17 Active ligatures vs NiTi springs 0.46 0.15 0.017 0.85 0.069 Powerchain vs NiTi springs 0.23 0.16 0.50 0.63 0.18 *There was no interaction with inter-arch elastic wear and space closure method (P 0.30), and there was no effect of the use of Class II or Class III elastics on rate of space closure (P 0.61). potentially significant. For example, compare a patient with no space left at 4 months and one with 2 mm of space left in any quadrant. The latter patient would potentially have a different amount of extra time in treatment to complete space closure depending on the method used (2 mm divided by the monthly space closure rate), i.e. 5.7 months with active ligatures, 3.4 months with powerchain, and 2.5 months with NiTi springs. In addition, there are factors such as cost-benefit and chairside time to be considered when choosing the method of space closure. NiTi springs are the most expensive option, but have the advantage of being efficient and relatively quick to re-activate. Powerchain is cheaper, but is likely to take a little longer to replace at each visit. The chairside time with active ligatures is also likely to be increased because of their replacement at each visit and the increased number of visits required to obtain the same amount of space closure in comparison with the other methods. The lack of effect of inter-arch elastics on the rate of space closure It was surprising that we did not find any effect of Class II or Class III elastics on rates of space closure. Theoretically, it would seem that inter-arch elastics should speed up space closure, however, there may some explanation for their lack of effect: The study lacked statistical power to detect an elastic effect. The elastic force may not have been sufficient to influence rates of tooth movement Patients may not be co-operating totally with full time elastic wear The inter-arch elastics are moving blocks of teeth in each arch in an anterior or posterior direction without significantly adding to the space closing effect. For certain force levels, the addition of elastics may not increase the rate of tooth movement at the histological level. Method issues Internal and external bias. Consideration of internal bias is important because of the risk of biased comparisons of the interventions in the trial. Internal bias has been minimized in this trial in the following ways: Application of strict inclusion criteria. No patient refused to take part in the trial. Concealment of treatment allocation until the time of treatment. Standardization of treatment methods. The examiner making the measurement was blind to the treatment allocation. One potential source of bias within this trial was attrition bias, since two patients were lost from the powerchain group and one from the NiTi group. Usually, a statistical comparison of the drop-outs and patients remaining in the study is carried out in an effort to ascertain that the patients lost are no different to the ones remaining in the trial. In this case, it was not considered useful to compare the start space, in each quadrant, for the patients who were lost and the study patients. Generally, it was thought that even with this

36 V. Dixon et al. Scientific Section JO March 2002 potential source of bias, that external bias would be minimal and that the findings of the study were applicable to the general population of orthodontic patients. Conclusions Our study has shown that NiTi springs gave the most rapid rate of space closure and may be considered the treatment of choice. However, powerchain provides a cheaper treatment option that is as effective. The use of inter-arch elastics does not appear to increase rates of space closure. Acknowledgements Thanks go to all clinicians that placed their patients on this trial. References 1. Quinn RS, Yoshikawa DK. A reassessment of force magnitude in orthodontics. Am J Orthod 1985; 83: 252 260. 2. Samuels RHA, Rudge SJ Mair LH. A comparison of the rate of space closure using a nickel titanium spring and an elastic module: A clinical study. Am J Orthod 1993; 103: 464 467. 3. Rock, W.P., Wilson, H.J. & Fisher, S.E. Force reduction of elastomeric chains after one month in the mouth. Br J Orthod 1986; 13: 147 150. 4. Kuster, R., Ingervall, B. & Burgin, W. Laboratory and intra oral tests of the degradation of elastic chains. Eur J Orthod 1986; 8: 202 208. 5. Lu, T.C., Wang, W.N., Tarng, T.H. and Chen, J.W. Force decay of elastomeric chain A serial study. Am J Orthod Dentofacial Orthop 1993; 104: 373 377. 6. Baty, D.L., Storie, D.J. & von Fraunhofer, J.A. Synthetic elastomeric chains: A literature review. Am J Orthod Dentofacial Orthop 1994 Jun; 105(6): 536 542. 7. Sonis, A.L. Comparison of NiTi coil springs versus elastics in canine retraction. J Clin Orthod 1994; 28: 293 295. 8. Samuels, R.H.A., Rudge, S.J. & Mair, L.H. Study of space closure with nickel titanium closed coil springs and an elastic module. Am J Orthod 1998; 114: 73 79. 9. Manhartsberger, C. & Seidenbusch, W. Force delivery of NiTi coil springs Am J Orthod Dentofacial Orthop 1996; 109: 8 21. 10. O Brien, K.D., Lewis, D.H., Shaw, W.C. & Combe, E. A clinical trial of aligning archwires. Eur J Orthod 1990; 12: 380 384. 11. Nattrass, C., Ireland, A. & Sherriff, M. An investigation into the placement of force delivery systems and initial forces applied by clinicians during space closure. Br J Orthod 1997; 24: 127 131. 12. Proffitt, W.R. Equilibrium theory revisited: factors influencing the position of the teeth. Angle Orthod 1978; 48: 175 186. 13. Proffitt, W.R. On the aetiology of malocclusion. Br J Orthod 1986; 13: 1 11. 14. Han, S. & Quick, D.C. Nickel titanium spring properties in a simulated oral environment. Angle Orthod 1993; 63: 67 72.