Parametric Release Regulatory Requirements. Terry E. Munson Technical Vice President PAREXEL International, LLC

Similar documents
Sterility Assurance and Risk Management: A CDER Microbiologist s Perspective

Single market, regulatory environment, industries under vertical legislation Pharmaceuticals : regulatory framework and market authorisations

Stonegate Pharmacy LP 11/10/16

Product Sterility Testing... To Test or Not to Test? That Is the Question

STERILITY TESTING OF PHARMACEUTICAL PRODUCTS

Inspections, Compliance, Enforcement, and Criminal Investigations

Misconceptions with Moist Heat Sterilization Roy McLean

Residual Solvents: FDA/ Regulatory Perspective

Hieber's Pharmacy 12/5/17

Raritan Pharmaceuticals, Inc. 6/20/17

Larry! 28/06/2016. House Keeping. Welcome! From the GoToWebinar page:

Draft Guidance for Industry and FDA Staff

TSDR Pharmacy Inc. dba brandmd Skin Care 11/9/17

Public Health Service Food and Drug Administration Dallas District 4040 North Central Expressway Dallas, Texas

The proposed rule is significant, and the requirements and exceptions are complex. Key provisions of the proposal are described below.

AKA Good Manufacturing Practice (GMP) Certification Program

Inspections, Compliance, Enforcement, and Criminal Investigations

FDA 510(k) 101 The Basics

Aseptic Process Simulation (APS) Program Risk Assessment

Inspections, Compliance, Enforcement, and Criminal Investigations

Unidirectional Airflow Smoke Test Protocol

Excipient Risk Assessment

4/26/2013. Libia Lugo Drug Specialist San Juan District Office Investigations Branch

Monitoring The Sterilization Process. Are We Over The Top?

Healthcare Sterilisation: Introduction and Standard Practices, Volume 1

A WHITE PAPER STERILITY TESTING ESSENTIAL THINGS YOU MUST KNOW

DEPARTMENT OF HEALTH & HUMAN SERVICES Food and Drug Apini$r$iy -tq 5-f

Introduction. Current status of 510(k) clinical data requirements. 1 Current Status&Considerations:

Town and Country Compounding and Consultation Services, LLC 10/17/17

PDA Points to Consider relating to EU GMP Annex 1 changes. Presented by Ashley Isbel 30 November, 2016

Validation Introduction. Presented by John Montalto 27 March, 2013

Status Update on the Review of DMFs

510(k) submissions. Getting US FDA clearance for your device: Improving

How Do You Know If a Sterilized Package Remains Sterile?

Overview of Dietary Supplement GMP Inspection Trends Quality Session 6

How Do You Know If Your Sterilized Instruments Remain Sterile?

Sandoz Inc. 12-Aug-08

Reishi D. International, Inc. 2/6/18

HOGAN & IFbuxrso~ LLP.

Inspections, Compliance, Enforcement, and Criminal Investigations

Agency Information Collection Activities; Submission for Office of Management and

Sterilization of health care products Radiation. Part 2: Establishing the sterilization dose

Certifications & Approvals

Complex Medical Devices and Steam Sterilization. By Andrew Gay Director - Sterilizer Validation Australia

Proper CMC Submission -API. Ramnarayan Randad, Ph.D. DMF Review Staff/OGD June 4, 2014 GPhA/FDA Bethesda, MD

FOOD SCIENCE AND NUTRITION

LEAF Marque Assurance Programme

Curriculum Vitae. Lone Cleveland Andersen. Courses

Please find enclosed Dosimetry Service Licence No which replaces Dosimetry Service Licence No

EU Regulatory Update & GMP Deficiencies. Bryan J Wright July 2017

FOOD AND DRUGS AUTHORITY (FDA) GHANA

MHRA Pharmacovigilance Inspections: Prepare and Manage for Success

BEST PRACTICE CHANGE CONTROL : DECIDING WHEN TO SUBMIT A 510(K) FOR A DEVICE CHANGE. Yuan Xu 18- JAN- 2018

Food Safety Modernization Act - Impacts on the Grain and Feed Industry

Alignment of FSMA with Existing Food Safety Programs International Citrus & Beverage Conference

Aer ODE B3-20. Database System for GEX B3 Dosimetry. Aérial. Optical Dosimetry Equipment. (gamma and/or electron beam versions)

Revised August 28, 2018

Technical requirements Nutrition products

Inspections, Compliance, Enforcement, and Criminal Investigations. Central Texas Regional Blood & Tissue Center 07-Nov-03

QA Program Evaluation Research Tool CF-195, Effective

STANDARD FOR PORCINE SEMEN QUALITY IN AI CENTRES

DETERMINING WHETHER AN ACTIVITY IS HUMAN SUBJECTS RESEARCH AS DEFINED BY FEDERAL REGULATIONS

Agency Information Collection Activities; Submission for Office of Management and Budget

TAMPA ELECTRIC COMPANY ENERGY SUPPLY HEARING CONSERVATION PROGRAM

PIC/S GUIDANCE ON CLASSIFICATION OF GMP DEFICIENCIES

Risk Based Environmental Monitoring

Committed to Environment, Health, & Safety

New TGA Requirements for Microbiology

INTERNATIONAL CONFERENCE ON HARMONISATION OF TECHNICAL REQUIREMENTS FOR REGISTRATION OF PHARMACEUTICALS FOR HUMAN USE

Medidée Services SA. Nano-Tera.ch. 05 February 2015 part 4. Intro ISO GMP - GLP Pierre-Alain Sommer

Proficiency Testing Policy

Healthcare Sterilisation: Challenging Practices Volume 2

Guide to Registration of Homeopathic Veterinary Medicinal Products

040716_ANDI_VENTIS WEBSITE(new) Printout 1. HOME PAGE. Welcome to our world of Dry Powder Inhalers!

AMERICAN BOARD OF CRANIOFACIAL DENTAL SLEEP MEDICINE

Page 1132

Alcohol and Drug Testing for Employees with Commercial Drivers' License

ALCOHOL AND DRUG-TESTING OF BUS DRIVERS REGULATION

Sterile U Network. Quality Control for Table-top Steam Sterilizers. Introduction: T U T O R I A L S

ANDA Submissions Refuse to Receive for Lack of Proper Justification of Impurity Limits Guidance for Industry

Case 2:18-cv JTF-dkv Document 1 Filed 09/25/18 Page 1 of 17 PageID 1 IN THE UNITED STATES DISTRICT COURT FOR THE WESTERN DISTRICT OF TENNESSEE

Sterilization of health care products - Radiation - Part 2: Establishing the sterilization dose

INTRODUCTION TO DRUG LAW AND REGULATION: REGULATION OF DRUG MANUFACTURING

Environmental Certification Services Indoor Air Quality Certification Manual

cgmp (21 CFR 111) Regulation and Compliance Overview

FILL AMOUNT CONTROL FOR LIQUID AND SEMISOLID DOSAGE FORMS


CO SPONSORED BY. November 14, 2018 DoubleTree by Hilton Hotel Rochester Rochester, MN

Brazilian Official Gazette (Diário Oficial da União DOU) of 1 February 2010

ISO INTERNATIONAL STANDARD. Sterilization of health care products Radiation Part 2: Establishing the sterilization dose

Food Additives Program

Rock Solid Nutrition, LLC 12/22/16

Autism Speaks Translational Postdoctoral Fellowship Program 2011 Request for Applications

ISO 13485:2016 MEDICAL DEVICES QMS TRANSITION GUIDE

INTERNATIONAL CONFERENCE ON HARMONISATION OF TECHNICAL REQUIREMENTS FOR REGISTRATION OF PHARMACEUTICALS FOR HUMAN USE

Issue Date: 5/15/18 Supersedes Version Dated: 8/1/16 Page 1 of 5

Good Laboratory Practice. EU-Serbia screening meeting Brussels, 19 June 2014

Environmental Monitoring How to Satisfy the Regulator. Presented by Tanja Varglien, July 2017

Module 34: Legal aspects, ADI and GRAS status of food additives

Transcription:

Parametric Release Regulatory Requirements Terry E. Munson Technical Vice President

History First application approved for parametric release in 1985 Formed the basis for the FDA Compliance Policy Guide 7132a.13 issued in 1987 No further requests for parametric release until mid 90s FDA Submission Guideline issued February, 2010 October 22, 2010 2

CPG 7132a.13 Defined Parametric Release as a sterility release procedure based upon effective control, monitoring, and documentation of a validated sterilization process cycle in lieu of release based upon end-product sterility testing Only applies to terminal moist heat sterilization of drug products October 22, 2010 3

CPG 7132a.13 - Requirements Cycle has been validated to achieve microbial bioburden reduction to 10 0 with a minimum safety factor of an additional 6 log reduction. Cycle Validation Chamber Heat Distribution Load Configuration Heat Distribution Heat Penetration of Product Bioburden Studies Lethality Study referencing a test organism of known resistance Identify cycle parameters as Critical or non-critical Critical Time, Pressure, Temperature Non-Critical Heat-up Time, Cooling Time, etc. October 22, 2010 4

CPG 7132a.13 - Requirements Failure of more than one critical parameter must result in automatic rejection of the sterilizer load Integrity of the container closure system has been validated Bioburden Testing Total Aerobic Count Total Spore Count For each batch October 22, 2010 5

CPG 7132a.13 - Requirements Chemical or biological Indicators are included in each truck, tray or pallet of each sterilizer load. Chemical Indicators Cannot be used to evaluate cycle lethality Should have a time/temperature response Should be stable For each cycle - minimum degradation values established Biological Indicators Document biological indicator characteristics Can be used to evaluate cycle lethality Can be used in place of one critical parameter October 22, 2010 6

CPG 7132a.13 - Requirements Reason for having indicators in each load GMP regulation 21 CFR 211.167(a) requires that for each batch of drug product purporting to be sterile and/or pyrogen free, there shall be appropriate laboratory testing to determine conformance to such requirements. October 22, 2010 7

Submission Guideline - 2010 Submission of Documentation in Applications for Parametric Release of Human and veterinary Drug Products Terminally Sterilized by Moist Heat Processes, February 2010 Applicable to Human and Animal Drugs and Biological products. Parametric Release is defined as a sterility assurance release program where demonstrated control of the sterilization process enables a firm to use defined critical process controls, in lieu of the sterility test to fulfill the intent of 21 CFR 211.165(a) and 211. 167(a). October 22, 2010 8

Submission Guideline - 2010 Validation of the Sterilization Cycle Should be conducted in accordance with Submission of Documentation for Sterilization Process Validation in Applications for Human and Veterinary Drug Products, November 1994 Defines the criteria to be submitted in the application October 22, 2010 9

Submission Guideline - 2010 A sterilization load monitor, either in the form of a physical chemical or biological indicator, is included with each load to satisfy the requirement for a laboratory test. Required by 211.167(a) Must be placed in appropriate positions to indicate that the load was exposed to the sterilization process October 22, 2010 10

Submission Guideline - 2010 Content of the Submission Control Strategy for Terminal Sterilization Program Rationale for method used to monitor and control terminal sterilization process Rationale for selection of critical parameters Description of the acceptance criteria for parametric release Description of the proposed production loading pattern Description of microbiological monitoring plan for product and components October 22, 2010 11

Submission Guideline - 2010 Content of the Submission (cont.) Risk Assessment, process Understanding and Prior Knowledge Consistency of performance of the terminal sterilization cycle within validated limits Risk to sterility of product The terminal sterilization cycle Production loading pattern Container closure system Potential contamination risks from the environment Experience with the proposed or similar product or similar sterilization cycle Discussion of your overall prior knowledge and production and testing experience October 22, 2010 12

Submission Guideline - 2010 Content of the Submission (cont.) Documentation for Parametric Release Process Detailed description of the current terminal sterilization cycle Identification of the critical parameters minimum and maximum limits for each Certify that meeting critical parameters will be used as the primary release criterion for product release. Sterility test cannot be used to overrule failed cycles. Acknowledgement that any sample tested by the reference test method for sterility will pass October 22, 2010 13

Submission Guideline - 2010 Content of the Submission (cont.) Documentation for Parametric Release Process (cont) Description of the sterilization load monitors Type of monitor that will be used How the load monitor will be used and analyzed What functions are being measured by the monitor Rationale for the location of the monitor Recommends that Class 5 indirect monitors (ISO 15882, 2008) be used. Justification for the classification of the indirect monitors used Documentation of the control system to verify exposure of the load to the sterilization process Show the link between batch release criteria and the commitments in the application October 22, 2010 14

Filing Must submit an application for new drug products Must submit a prior approval supplement for already approve drug products October 22, 2010 15

FDA Approval Process Starts when application or supplement is accepted Reviewers will start review of the submitted documents At the same time a GMP status request is sent to the Office of Compliance in the respective Centers. Center for Drug Evaluation and Research Center for Veterinary Medicine Center for Biologics Evaluation and Research October 22, 2010 16

FDA Approval Process (cont) The Office of Compliance will query their database for the sites listed in the application/supplement. If last inspection over two year will send a request for inspection to the appropriate District Office. If GMP status questionable - will send a request for inspection to the appropriate District Office. If inspection and GMP status is acceptable will inform reviewers that GMP status is acceptable Application/Supplement will be approved if GMP status is acceptable and the documentation in the application/supplement meets October 22, 2010 17

EU Requirments In addition to the basic validation data the EU also Requires: Need sterility test history for acceptance A qualified sterility assurance engineer should be on site Need two independent systems to check for compliance to specifications October 22, 2010 18

Future Manufacturers are still going to be slow to implement parametric release because of the addition requirements put on the sterilization process. October 22, 2010 19

Contact Information Terry E. Munson Technical Vice President PAREXEL Consulting Phone: 1-571-436-7582 Email: terry.munson@parexel.com October 22, 2010 20