Metha Short Hip Stem System

Similar documents
Optimum implant geometry

Encina Taper Stem. Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

Optimizing function Maximizing survivorship Accelerating recovery

Aesculap Orthopaedics Excia. Hip Stem

Bone Preservation Stem

THE NATURAL FIT. Surgical Technique. Hip Knee Spine Navigation

Surgical Technique. Hip System

Taperloc Complete Hip System. Surgical Technique

Plasmapore XP. Stability that Starts at the Surface

Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

Revision. Hip Stem. Surgical Protocol

PL-AGE Cervical Stand Alone Device. Aesculap Spine

Bone Conserving Hip Replacement Surgical technique

Optimum implant geometry

Surgical Technique r5.indd 1 12/8/10 10:36 AM

TaperFill. Surgical Technique

Quintex Cervical Plating System

HELIOS h i p s y s t e m

Optimum implant geometry

Integra. Titan Modular Shoulder System, 2.5

Aesculap Trilliance Triple Tapered Polished Hip Stem

5A* ODEP. Conserving bone. Preserving soft tissue. Restoring biomechanics. rating

Surgical technique MkII instrumentation

Design Rationale. ECHELON Primary Hip System

SURGICAL TECHNIQUE. Alpine Cementless Hip Stem

Approach Patients with CONFIDENCE

ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY

ACTIS. TOTAL HIP SYSTEM Approach Active Patients with Confidence DESIGN RATIONALE

Progeny Hip Stem. Surgical Protocol and Product Specifications

ACETABULAR CUP SURGICAL TECHNIQUE

Approach Patients with Confidence

UNDERSTANDING TRADITION, MASTERING INNOVATION. Surgical Technique

Cementless Tapered Femoral Stem Surgical technique

asterloc Surgical Technique HIP SYSTEM UNDERSTANDING TRADITION, MASTERING INNOVATION Hip Knee Spine Navigation

Cementless Tapered Femoral Stem Surgical technique

Knee Revision. Portfolio

Surgical Technique. *smith&nephew POLARSTEM Cementless Stem System

Lumbar Total Disc Replacement. A Patient s Guide

S U R G I C A L T E C H N I Q U E

FIRST STEM SPECIFICALLY DESIGNED FOR AMIS. Surgical Technique

Surgical Technique VPLWK QHSKHZ 1$126 1HFN 3UHVHUYLQJ +LS 6WHP 1716-e_NANOS_OPT.indd :27

FLH /11

Approach Patients with Confidence

28 Surgical Technique

Ovation Hip System. Surgical Technique

HIP SYSTEM SURGICAL TECHNIQUE

CORAIL HIP SYSTEM SURGICAL TECHNIQUE

TOTAL HIP REPLACEMENT:

Arcos Modular Femoral Revision System

Fixed and Variable Geometry Total Shoulder Arthroplasty

3A ODEP. Preserving the natural anatomy and restoring patient biomechanics

Featuring. Technology. Product Rationale

CC TRIO VERSAFITCUP. Surgical Technique. each to their own. Hip Knee Spine Navigation

Hip Resurfacing.

ZMR Crossover Instruments. Abbreviated Surgical Technique

U2 PSA. Revision Knee. Surgical Protocol

CORAIL HIP SYSTEM DESIGN RATIONALE

Inspiring people, Enriching lives

Anterior Approach Surgical Technique. Paragon Stem System. enabling people to enjoy life

*smith&nephew SL-PLUS Cementless Femoral Hip System. Product Information

Operating Instruction. Müller Hip Stem

Continuing the Tradition. VerSys Heritage Hip System

EXTENDED TROCHANTERIC OSTEOTOMY SURGICAL TECHNIQUE FPO EXTENSIVELY COATED FIXATION

UTF Stem. reduced. Surgical Protocol

VerSys LD/Fx Cemented and Press-Fit Hip Prostheses. Surgical Technique IMAGE TO COME. Versatile solutions for total and partial hip replacement

DESIGN RATIONALE AND SURGICAL TECHNIQUE

9800 Metric Blvd. Austin, Texas

Preoperative Planning. The primary objectives of preoperative planning are to:

The science of simplicity

*smith&nephew SL-PLUS

FIRST STEM SPECIFICALLY DESIGNED FOR AMIS. Surgical Technique

PLR. Proximal Loading Revision Hip System

Predicting the Position of the Femoral Head Center

Tri-Lock Bone Preservation Stem

Integra. DigiFuse Cannulated Intramedullary Fusion System SURGICAL TECHNIQUE

Clinical Evaluation Surgical Technique

S h o u l d e r Solutions by Tornier C o n v e r T i b l e S h o u l d e r S y S T e m

pact SYSTEM Surgical Technique HEMISPHERICAL CEMENTLESS CUP SYSTEM MULTI-HOLE & RIM-HOLE Hip Knee Spine Navigation

ZMR Over-the-Junction Instruments for Revision Hip Arthroplasty. Surgical Technique IMAGE TO COME

CAUTION Federal law (USA) restricts this device to sale, by or on the order of a physician.

simplicity THE SCIENCE OF DESIGN RATIONALE

ZMR CROSSOVER INSTRUMENTS AND SURGICAL TECHNIQUE. Surgical Technique for Revision Hip Arthroplasty

DIRECT ANTERIOR APPROACH

Bone Bangalore

MetaFix. Cementless Total Hip Replacement Surgical technique

Restoration Modular Revision Hip System. Choice Matters

Specifications guide ECHELON. Hip System

EMPERION Modular Hip System Surgical Technique

MetaFix. Cementless Total Hip Replacement Surgical technique

TriboFit Hip System. Issue 3 - August 2013 English

AML Hip System. Design Rationale/ Surgical Technique

PROFEMUR Total Hip System P R O D U C T C A T A L O G

Reaching new heights. Comprehensive. Efficient. Simple.

Tissue Sparing. DEsign Rationale

EVOLVING OUR HERITAGE, MEETING YOUR NEEDS. Surgical Technique

A U X I L I A R Y C O N N E C T O R S Surgical Technique

Integral 180 Surgical Technique

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique

Transcription:

Metha Short Hip Stem System Accuracy That Stands Alone Aesculap Orthopaedics

Metha Short Hip Stem System Designed For Anatomic Accuracy The Metha Short Hip Stem is designed for anatomic accuracy to restore natural biomechanics and ensure excellent joint stability. Guided by the femoral neck upon insertion, the stem anteversion and head position are designed for anatomic accuracy Biomechanical offset and leg length can be restored while achieving soft tissue balance around the hip joint The optimized position of the femoral head to the position of the cup reduces the risk of dislocation Meta-Diaphyseal Variability The Metha Short Hip Stem is positioned in the direction of each patient s femoral neck, restoring natural biomechanics and ensuring exceptional joint stability. 2

True Metaphyseal Anchoring The Metha Short Hip Stem achieves true metaphyseal anchoring, re-establishing physiological conditions, for successful total hip arthroplasty. Fixation within the closed ring of the femoral neck and lateral neck support provides primary implant stability Stem placement on the medial calcar restores a more physiological strain distribution, thereby decreasing stress shielding A proximal-bilateral conical stem shape encourages metaphyseal load transfer and supports primary stability The smoothed and slightly curved distal tip is guided along the dorsolateral cortex, preventing diaphyseal fixation and reducing the risk of thigh pain offset 50 15 10 5 0 5 optimal position The Metha Short Hip Stem has one straight medial design, allowing implantation at various varus/valgus positions that adjust to individual bone morphology and ensure primary stability by close contact with the medial calcar. 3

Metha Short Hip Stem System Bone and soft tissue Preserving The Metha Short Hip Stem addresses the growing demand for bone and soft tissue preservation through a minimally invasive implantation. Moreover, the preserved bone stock allows for an improved potential revision situation, where a standard implant can be used instead of a longer revision stem. Introduction through the femoral neck and high 50 degree osteotomy eliminates disruption of the greater trochanter and surrounding muscles Minimal lateral shoulder design conserves bone in the greater trochanter while the reduced length maintains femoral canal integrity Broach only technique facilitates minimal endosteal disturbance Metha Short Hip Stem in the lateral view Metha Short Hip Stem in the AP view 4

Surface technology for Long-term Stability Plasmapore surface coating enhances the Metha Short Hip Stem s stability. Built on Expertise Aesculap has over 20 years of expertise in applying Plasmapore coatings onto orthopaedic and spine implants. The resorbable, porous Long-Term Stability Plasmapore µ-cap The advanced coating technology is a coating; x 800 combination of a Plasmapore microporous titanium rough coating and a thin bioactive calcium phosphate surface finish. The calcium phosphate is intended to be osteoinductive while the porous Plasmapore structure offers an optimal foundation for potential bone growth. The improved anchoring of the implant results in a more physiologic transmission of forces at the interface between bone and the implant helping to ensure reliable, long-term stability. Note the radiographic increase in bone density in the medical calcar region 5

Metha Short Hip Stem System Accommodates preferred surgical approach with Simplicity The Metha Short Hip Stem provides surgical approach flexibility with instrumentation that accommodates both traditional and less invasive approaches. The broach-only technique simplifies the procedure for the surgeon while the two-tray system facilitates operating room efficiency. NF140R Angled handle for direct anterior approach NF180R Straight handle for lateral and anterolateral approaches NF141R, NF142R Offset handles* NF144R Curved handle for posterior approach *Note: NF141R for the left hip (lateral and anterolateral approaches) or right hip (posterior approach) NF142R for the right hip (lateral and anterolateral approaches) or left hip (posterior approach) 6

Clinical Data 1. Mihalko, W. THA through a direct anterior approach spares muscle, expedites recovery. Orthopedics Today. 2011 April;31(4). 2. Lerch, M. Bone remodelling around the Metha short stem in total hip arthroplasty: a prospective dual-energy X-ray absorptiometry study. International Orthopaedics (SICOT). 2011;36(3):533-538. 3. Wittenberg, R.H. et al. Five -year results of a cementless short-hip stem prosthesis. Orthopedic Reviews 2013;5:e4 Contact your Aesculap Sales Representative to access this clinical information. Indications for Use The Metha Hip System (uncemented, press fit fixation) is intended to replace a hip joint. The device is intended for: Skeletally mature individuals undergoing primary surgery for total hip replacement Patients suffering from severe hip pain and disability due to rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis, collagen disorders, avascular necrosis of the femoral head and nonunion of previous fractures of the femur. Patients with congenital hip dysplasia, protrusion acetabuli, or slipped capital femoral epiphysis Patients suffering from disability due to previous fusion Patients with acute femoral neck fractures Contraindications Do not apply in the presence of: Joint diseases that can be treated with reconstructive surgery (e.g. displacement osteotomy) Acute or chronic infections near the joint or systemic infections Secondary diseases that could influence joint implant functionality Systemic diseases and metabolic disturbances Acute osteoporosis or osteomalacia Severely damaged bone structures that could prevent stable implantation of implant components Bone tumors in the region of implant fixation Bone deformities, axis misalignments, or other bone conditions that rule out the implantation of a hip joint prosthesis preserving the collum femoris Anticipated excessive load on the joint implant Dependency on pharmaceutical drugs, drug abuse, or alcoholism Medicinal Inadequate patient compliance Foreign body sensitivity to the implant materials Skeletal immaturity Neuromuscular diseases impairing the affected extremity Prosthesis head with neck length XL in combination with short stem prosthesis sizes 0 and 1 Prosthesis heads with neck length XXL See Instructions for Use for complete indications, contraindications, precautions and warnings at www.aesculapimplantsystems.com. 7

All rights reserved. Technical alterations are possible. This leaflet may be used for no other purposes than offering, buying and selling of our products. No part may be copied or reproduced in any form. In the case of misuse we retain the rights to recall our catalogs and price lists and to take legal actions. 2014 AESCULAP. ALL RIGHTS RESERVED. PRINTED IN THE USA. Aesculap is an equal opportunity employer Aesculap Implant Systems, LLC 3773 Corporate Parkway Center Valley, PA 18034 Phone 866-229-3002 Fax 610-984-9096 www.aesculapimplantsystems.com Aesculap Implant Systems, LLC - a B. Braun company DOC1128 2M 3/14