Proven technology for customized solutions. Revitan Curved Revision Hip System

Similar documents
A further enhanced classic. Wagner SL Revision Hip Stem

A Proven Concept. Alloclassic Zweymüller Stem

Alloclassic Zweymüller Stem

*smith&nephew SL-PLUS Cementless Femoral Hip System. Product Information

CLS Spotorno Hip Stem A Milestone in the History of Hip Replacements

ZMR Crossover Instruments. Abbreviated Surgical Technique

PLR. Proximal Loading Revision Hip System

Avenir Femoral Hip System

ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY

*smith&nephew SBG Anatomical Hip Stem Prosthesis. Product Information

CLS Brevius Stem with Kinectiv Technology

Revitan Straight. Surgical Technique. PFM-Revision of the Second Generation

Allofit /Allofit -S Alloclassic Acetabular Cup System

Revitan Curved. Surgical Technique. Modular Femoral Revision Prosthesis

Operating Instruction. Müller Hip Stem

Expand your Options. REX cement stop System

ZMR CROSSOVER INSTRUMENTS AND SURGICAL TECHNIQUE. Surgical Technique for Revision Hip Arthroplasty

The proven, simple solution. CPT 12/14 Hip System

Encina Taper Stem. Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

Design Rationale. ECHELON Primary Hip System

ZMR Over-the-Junction Instruments for Revision Hip Arthroplasty. Surgical Technique IMAGE TO COME

Sirus Antegrade Femoral Nail System Surgical Technique

Bone Preservation Stem

Aesculap Trilliance Triple Tapered Polished Hip Stem

operative technique Kent Hip

Restoration Modular Revision Hip System. Choice Matters

9800 Metric Blvd. Austin, Texas

Surgical Technique VPLWK QHSKHZ 1$126 1HFN 3UHVHUYLQJ +LS 6WHP 1716-e_NANOS_OPT.indd :27

Metasul LDH Large Diameter Head

Section of Modular Hip Prostheses cemented. TMC-3 Modular Hip Prosthesis, cemented. TMC-3 Modular Hüftprothese, zementiert

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter

SURGICAL TECHNIQUE. Alpine Cementless Hip Stem

Continuing the Tradition. VerSys Heritage Hip System

Optimum implant geometry

CeramTec Medical Products. BIOLOX DUO Ceramic Bipolar System. Bone-sparing joint reconstruction with a maximum range of motion

NCB Large Fragment System. Surgical Technique

Specifications guide ECHELON. Hip System

Anatomical Shoulder Glenoid. Surgical Technique

VerSys LD/Fx Cemented and Press-Fit Hip Prostheses. Surgical Technique IMAGE TO COME. Versatile solutions for total and partial hip replacement

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

RECLAIM REVISION HIP SYSTEM

Zimmer Trabecular Metal Ankle Interpositional Spacer and Trabecular Metal Ankle Fusion Spacer

Optimum implant geometry

Optimum implant geometry

CLS Spotorno Hip Stem. Surgical Technique

Medical Products Division. BIOLOX DUO Ceramic Bipolar System. Bone-sparing joint reconstruction with a maximum range of motion

One system for all revision types

Surgical Technique. Hip System

THE NATURAL FIT. Surgical Technique. Hip Knee Spine Navigation

Anatomical Shoulder Fracture. Surgical Technique

Reaching new heights. Comprehensive. Efficient. Simple.

VLIFT System Overview. Vertebral Body Replacement System

Bi-Polar 22.2mm & 28mm System - Operative technique

Surgical Technique. Unisyn Hip System

CLS Spotorno Hip Stem

PFNA. With Augmentation Option.

comprehensive Design Rationale shoulder system Knees Hips Extremities Cement and Accessories PMI TEchnology

PediLoc 3.5mm and 4.5mm Contour Femur Plate Surgical Technique

Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

Revision Modular Stem type RMD

Progeny Hip Stem. Surgical Protocol and Product Specifications

NCB Proximal Humerus Plating System

Integra. Titan Modular Shoulder System, 2.5

Revision. Hip Stem. Surgical Protocol

ACOR cementless anatomical femoral stem with a modular neck

Arcos Modular Femoral Revision System

Zimmer MMC Cup. Surgical Technique. Large Diameter Metal-on-Metal

Following a tradition of success. VerSys Heritage Primary Hip Prosthesis Surgical Technique

The bi-metric XR series of Hip implants blends biomet s proven philosophy and tradition with Advanced technology. porous primary hip series

WAGNER CONE PROSTHESIS. Surgical Technique

LPS SYSTEM POCKET GUIDE

Bone Conserving Hip Replacement Surgical technique

*smith&nephew SLR-PLUS

Featuring. Technology. Product Rationale

Scan Bi-Polar 22/28. Operative Technique

Wagner SL Revision Hip Stem

CPCS. Training Manual. Collarless Polished Cemented Stem

PediLoc Tibia Surgical Technique

CLS Spotorno Hip Cup. Surgical Technique. Nature as Model

Bone Bangalore

Modular Unipolar Femoral Head Replacement. Surgical Technique

PediLoc 3.5mm and 4.5mm Bowed Femur Plate Surgical Technique

3.5 mm Locking Attachment Plate

LCU Hip System cementless

EXACTECH KNEE. Operative Technique ADDENDUM. Metaphyseal Cones. Surgeon focused. Patient driven. TM

Diaphyseal implant surgical technique

Technique Guide. Locking Attachment Plate. For treatment of periprosthetic fractures.

INTRAMEDULLARY NAILING TIBIA AND FEMUR 1.3 TIBIAL AND FEMORAL NAILING FEMORAL NAILING WITH RETROGRADE INSERTION IMPLANTS AND OPERATING MANUAL

Absolut TM Cemented Stem. Surgical Technique

Comprehensive. Simple. Efficient.

Cementless Tapered Femoral Stem Surgical technique

Answer. Hip System Design Features:

TRAUMATOLOGY. Trochanter

PFNA. With Augmentation Option.

Distal Humerus surgical technique

M-SERIES. Modular Femoral Stem AN ACCURATE MATCH EVERY TIME

Titel. *smith&nephew MODULAR-PLUS. Text. Cementless Modular Revision System. Surgical Technique

NCB Distal Femur System. Surgical Technique

Approach Patients with Confidence

Transcription:

Proven technology for customized solutions Revitan Curved Revision Hip System

Disclaimer This document is intended exclusively for physicians and is not intended for laypersons. Information on the products and procedures contained in this document is of a general nature and does not represent and does not constitute medical advice or recommendations. Because this information does not purport to constitute any diagnostic or therapeutic statement with regard to any individual medical case, each patient must be examined and advised individually, and this document does not replace the need for such examination and/or advice in whole or in part. Information contained in this document was gathered and compiled by medical experts and qualified Zimmer personnel. The information contained herein is accurate to the best knowledge of Zimmer and of those experts and personnel involved in its compilation. However, Zimmer does not assume any liability for the accuracy, completeness or quality of the information in this document, and Zimmer is not liable for any losses, tangible or intangible, that may be caused by the use of this information.

Revitan Curved Revision Stem: Based on 1, 2, 3 Clinically Proven Implant Technologies The modular Revitan System incorporates the knowledge gained from clinical experience with cementless revision surgery during the last 20 years *. The forged cobalt-chromium connection taper was introduced in 1990 and has been used successfully during 1, 2 the past 15 years. The modularity of the Revitan Curved Revision Stem allows the surgeon to treat a wide range of indications. Revitan Curved offers a flexible and customized solution for demanding revisions. The precision-manufactured forged CoCr connection taper provides strength and reliability to the Revitan Revision System. The radius of the distal component is designed to fit the antecurvation of the femur and contributes to the good clinical results 4 achieved with Revitan Curved since its market introduction in 2002. There is an option to use locking screws to provide additional distal fixation. The intraoperative flexibility of the system is supported by a totally modular instrument set. This set facilitates efficient fixation, control of component anchorage and leg length at each step of the surgery. The Revitan Revision System has an optimized range of implants leading to a lean portfolio of only 33 implant components. Revitan Curved allows the surgeon to take optimal advantage of the modular revision stem concept and to achieve reproducible results. * based on the Wagner SL Revision (since 1987), PFM-R (since 1996) and Revisal-M (since 1996) systems

The Revitan Curved Implant System: The Distal Components The distal components of the Revitan Curved are based on the Revisal M stem, which has shown excellent clinical outcomes 5 since its introduction in 1994. The radius of the distal component is equal to that of the Revisal M stem and is designed to optimally fit the antecurvation of the femur. The benefits of this design feature have been confirmed through clinical experience with the Revisal M stem. 6 The Revitan Curved distal components are available in three different lengths: 140, 200 and 260 mm. Their diameters are between 14 and 28 mm, provided in 2 mm increments. The cross-section is octagonal with a rib on each edge providing high rotational stability. The stem has a 2 taper, which assures good primary anchorage and even distribution of the axial load. Furthermore, in the case of secondary subsidence, the movement of the component is reblocked due to the taper design. All stems with diameter $ 18 mm and length $ 200 mm have holes for locking screws, with the possibility of static and dynamic fixation. Locking screws can be used to further improve stability of distally fixed implants in specific cases such as in osteoporotic bone or a deficient isthmus. The octagonal cross section with ribs on each edge provides high rotational stability, and favors osseointegration. 4

The Proximal Components The proximal components of the Revitan Revision System are available in two different designs: cylindrical and conical. Both are provided in six different lengths from 55 to 105 mm (in 10 mm increments). The distal and proximal components can be selected and combined to achieve the best anchorage and optimal leg length. The slim neck and the short taper of the proximal Revitan Component enable large range of motion and reduce the risk of impingement. Cylindrical Component Less prominent ribs in the sagittal plane. Slim design to prevent proximal jamming. The CCD angle is constant at 135 and the offset is 44 mm, allowing for good function of the gluteal muscles. There are two holes in the medial part for nonmetallic sutures. Dorsal and ventral ribs allow a press-fit in the tensile and compressive stress-free zone of the proximal femur. The conical component contributes significantly more to efficient primary anchorage than a cylindrical component in the case of a metadiaphyseal anchorage with the endofemoral approach. This is due to the additional and larger ribs and the shape and volume of the conical component. Conical Component Conical design with additional lateral ribs enabling anchorage in the metadiaphyseal region of the femur. 5

Revitan Curved Implant System: A Customized Solution The overall length of the Revitan Curved System (proximal plus distal components) ranges from 195 mm to 365 mm, available in 10 mm increments. The modularity and the different combinations enable the surgeon to ensure the optimal leg length without compromising anchorage. 44 mm 44 mm 44 mm 44 mm 44 mm 44 mm 140 200 260 mm 55 65 75 85 95 105 mm 6 14 24 mm 8 14 28 mm 7 16 28 mm 6

Revitan Connection Taper: Flexibility- and Safety-based on Proven Technology The modular Revitan Revision System is based on the concept of distal press-fit anchorage introduced by Prof. H. Wagner. This concept demands reliable connection technology and intraoperative flexibility when assembling the components. The stem does not need proximal support to withstand forces exerted on it. The Revitan Connection Taper was introduced in 1990 and has been used in more than 20,000 cases. The taper is made with highest precision of a forged Cobalt-Chromium (CoCr) alloy (Protasul 21WF), which has a higher strength than other materials (e.g. titanium alloys). With this geometry of four zones, the maximal stress of the bending forces is concentrated on the section with the smallest diameter. This feature prevents formation of metallic debris as there is no contact between the proximal and distal implant components in this section. User-friendly instruments make it easy to assemble the components in situ. In case of secondary revision, the connection allows for intraoperative dismantling of the components. This assures easy and optimal adjustment of leg length and antetorsion. Both adjustments can be done in two independent steps. The Revitan Connection Taper is Divided into Four Zones Screw thread for the conical nut 40 +40 Cylindrical zone for centering both components during assembly Conical zone with structured surface to assure mechanical connection between the components Zone with smaller diameter to concentrate the flexion forces and to prevent metal abrasion during micromovement Antetorsion of the proximal component can be set freely in the range of 640. 7

The Anchorage: As Physiological as Possible The Revitan Curved Implant is designed to achieve primary stability irrespective of the surgical approach (endofemoral or transfemoral). This gives the surgeon the possibility to choose the optimal strategy depending on the amount of bone loss. The versatility of the modular instrument set helps the surgeon to reach this goal. Good physiological anchorage is possible for many different bone defects. Optimal Condition for Efficient Anchorage A precisely prepared, conically shaped anchorage bed is crucial for an efficient press-fit with the double-cone principle. 7 For each stem size the instrument set includes a matching rasp enabling the optimal preparation of the anchorage zone. The stable initial fixation is crucial for osseointegration and long-term fixation. The 2 taper design of the distal component reblocks the movement of the implant in case of secondary subsidence. The Concept is Histologically Proven Histological examinations based on the Wagner SL Revision Stem prove that the biomechanical anchorage principle works. 8 This principle is also used in the Revitan Curved with its 2 taper design, longitudinal ribs and material composition. The Wagner concept of distal fixation is valid for the Revitan Curved when using the transfemoral approach. 7 This fixation can be achieved through circular surface fixation. 7 Reduced Risk for Stress-Shielding The design, material and instruments interplay in a complementary manner. This reduces the risk of stress-shielding: Due to the characteristic crosssection and tapered design of the Revitan Stem, the medullary canal is not fully occluded. Together with the favorable properties of the titanium alloy Protasul-100 this assures the necessary elasticity even after implantation of stems with larger diameters. The application of precise rasps enables the controlled anchorage by press-fit in well defined and limited contact zones between bone and implant in order to prevent excessive stiffening of the femur. Additional Fixation Options There is an option to use locking screws to provide additional distal fixation. This option is especially important in osteoporotic bone where the medullary canal has expanded and no isthmus exists. Additional distal fixation is also useful in periprosthetic fractures with long spiral fractures in or above the isthmus region. With the transfemoral approach a circular press-fit fixation equivalent to the fixation of the Wagner concept is achieved. The endofemoral approach leads to a three-surface fixation with contact zones of approximately 5 cm length which is sufficient to ensure rotational stability. The ribs along the edges of the Revitan Stem cut into the cortical bone, ensures rotational stability and favors osseointegration. The grooves and ribs are crucial elements for physiological anchorage. Foto: B. Fink et al. 7 Springer Medizin Verlag 8

Instruments: A Requirement for Reproducible Results One advantage of the Revitan Curved system is the fully modular and easy-to-use instrument set. It is composed of modular rasps, modular trial prostheses and a targeting device for interlocking screws. The modularity offers total intraoperative flexibility. The Revitan Instrument System meets the requirements of modular implant surgery: anchorage of the stem and adaptation of leg length are performed in two fully independent steps. All this is done without compromising quality and safety of surgery. Targeting device A separate modular rasp is available for each implant size. The rasps allow for controlled and stepwise preparation of the medullar canal. This ensures an optimal anchoring bed even in difficult bone situation. These steps facilitate an efficient press-fit to achieve primary stability. Trial reposition can be performed at each step during surgery. This facilitates optimal adjustment of leg length and antetorsion setting. In the case of intraoperative correction or secondary revision, the instruments permit easy replacement of the proximal component. The small number of easy-to-use instruments allow for controlled and efficient implantation. The Revitan instrument set comes in four trays assuring good overview of all components. Modular rasp A targeting device locates the exact position of the locking holes without the need of the C-arm. Thanks to this, patients and operation room staff have no exposure to radiation and operating time is reduced. 9

Case Reports Case 1: Endofemoral Approach 77-year-old patient with aseptic loosening of cemented cup and stem, 12 years after implantation. Case 2: Transfemoral Approach Postoperative X-ray; noncemented revision via endofemoral approach of a Revitan Curved Stem and an Allofit-S Cup. Stable situation after 2 years. 65-year-old patient with hip pain and a partially loosen, rough-textured, noncemented stem. 10 Postoperative X-ray: revision with a Revitan Curved stem via a transfemoral approach. A transfemoral procedure was chosen to ease the extraction of the only partially loosened stem with its rough structured surface. Three cerclagewires were placed distally to prevent extension of a small shaft fissure. Stable situation after 2 years with complete consolidation of the bone flap.

Case 3: Periprosthetic Fracture 84-year-old man with periprosthetic fracture after cup revision. X-ray 1 year postoperative after revision with a Revitan Curved Stem. Two locking screws in medial-lateral direction placed below the isthmus provide additional stability. Case materials have kindly been provided by Professor B. Fink (Germany) and Professor K. Knahr (Austria). 1 Mc Innis D. et al.: Femoral Revision with a Fluted, Tapered, Modular Stem (Seventy patients followed for a mean of 3.9 years); The Journal of Arthroplasty, Vol. 21, No. 3, 2006. 2 Vendittoli P.A. et al.: Performance of Modular Tapered Fluted Titanium Stems for Femoral Revision ; Abstract 0-118 from the European Hip Society 2006 Domestic Meeting. 3 Böhm P. et al.: The Use of Tapered Stems for Femoral Revision Surgery ; Clinical Orthopedics and Related Research, No. 420, March 2004. 4 Fink B. et al.: Modified transfemoral approach to revision arthroplasty with uncemented modular revision stems. ; Operative Orthopädie und Traumatologie 1/07. 5 Schüler M.(2003): Der Revisal-M-Schaft, Entwicklung und erste Ergebnisse eines neuen, modularen und zementfreien Revisionsschaftes bei Hüfttotalendoprothesenwechseln und pertrochantären Femurfrakturen, Dissertation, Technische Universität München. 6 Knahr K. et al.: Der Revisionsschaft Revitan Kurviert: Konstruktionsmerkmale und Implantationstechnik, ÖGO Kongress 2003, Graz. 7 Fink B., Fuerst M., et al. (2005): Principles of fixation of the cementless modular revision stem Revitan. Unfallchirurg 108(12): 1029 1032, 1034 1037. 8 Schenk R. K., Wehrli U. (1989): Reaction of the bone to a cement-free SL femur revision prosthesis. Histologic findings in an autopsy specimen 5 1 2 months after surgery. ; Orthopäde 18(5): 454 462. 11

Copyright 2007 by Zimmer GmbH Printed in Switzerland Subject to change without notice. Contact your Zimmer representative or visit us at www.zimmer.com Lit.No. 06.01398.012 Ed. 03/2007 ZHUB +H84406013980121/$070301C07%