Long-term Outcome of Polished Stems in Total Hip Arthroplasty

Similar documents
Early failure of total hip replacements implanted at distant hospitals to reduce waiting lists

IMPROVED CEMENTING TECHNIQUES AND FEMORAL COMPONENT LOOSENING IN YOUNG PATIENTS WITH HIP ARTHROPLASTY

Charnley Total Hip Arthroplasty with Use of Improved Cementing Techniques A MINIMUM TWENTY-YEAR FOLLOW-UP STUDY

Twenty-five-Year Results After Charnley Total Hip Arthroplasty in Patients Less than Fifty Years Old A CONCISE FOLLOW-UP OF A PREVIOUS REPORT*

Continuing the Tradition. VerSys Heritage Hip System

ORIGINAL PAPER. Department of Orthopedic Surgery, Hamamatsu Medical Center ABSTRACT

Case Report Massive Femoral Osteolysis Secondary to Loosening of a Cemented Roughened Long Stem: A Case Report

Optimum implant geometry

Initial Evaluation on Subsidence of Cemented Collarless Polished Tapered Stem Applied to the Patients with Narrow Femoral Medullar Canal

Treatment of Periprosthetic Femoral Fractures Following Hip Arthroplasty

Femoral stem loosening rate of less than 0.16% per year at years 1. Exeter Hip

Femoral Osteolysis Around the Unrevised Stem During Isolated Acetabular Revision

Revision Total Hip Arthroplasty Using Tantalum Augment in Patients with Paprosky III or IV Acetabular Bone Defects: A Minimum 2-year Follow Up Study

Medium- to Long-term Results of Strut Allografts Treating Periprosthetic Bone Defects

Results of Conversion Total Hip Prosthesis Performed Following Painful Hemiarthroplasty

CIRCUMFERENTIAL PROXIMAL FEMORAL ALLOGRAFTS IN REVISION SURGERY ON TOTAL HIP ARTHROPLASTY: CASE REPORTS WITH A MINIMUM FOLLOW-UP OF 20 YEARS

The Effect of Hydroxyapatite Coating on Long-term Results of Total Hip Arthroplasty with Hydroxyapatite-coated Anatomic Femoral Stem

Ten-year survival of the cemented MS-30 femoral stem Increased revision rate in male patients

Bone Preservation Stem

Outcomes of Charnley total hip arthroplasty using improved cementing with so-called second- and third-generation techniques

Total Hip Arthroplasty Using Metal Head on a Highly Cross-linked Polyethylene Liner

Tri-Lock Bone Preservation Stem

Optimizing function Maximizing survivorship Accelerating recovery

Optimum implant geometry

Two Years Outcomes Of Total Hip Replacement Using A Short Stem With Femoral Neck Anchoring

CASE REPORT COMPLETE BONE REMODELING AFTER CALCAR RECONSTRUCTION WITH METAL WIRE MESH AND IMPACTION BONE GRAFTING: A CASE REPORT

The shape and size of femoral components in revision total hip arthroplasty among Chinese patients

Dissociation of Polyethylene Liner of the Dual Mobility Acetabular Component after Closed Reduction of Dislocation: A Case Report

21st Century Fracture Management ETS. Surgical Protocol

J of Evolution of Med and Dent Sci/ eissn , pissn / Vol. 4/ Issue 22/ Mar 16, 2015 Page 3785

Revision hip arthroplasty with S-ROM prosthesis: a study of clinical outcomes and implant stability

Revision Total Hip Arthroplasty Using an Extensively Porous Coated Femoral Stem

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter

Revision total hip arthroplasty with cemented femoral component

Following a tradition of success. VerSys Heritage Primary Hip Prosthesis Surgical Technique

Avenir Femoral Hip System

Optimum implant geometry

CPCS. Training Manual. Collarless Polished Cemented Stem

111. ACETABULAR FIXATION

The Exeter Universal stem

The Effect of Surface Finish and of Vertical Ribs on the Stability of a Cemented Femoral Stem

Comparative Study of Peripheral Rim Fixation Using Jumbo Cup in Revisional Hip Arthroplasty

Revision of the cemented femoral stem using a cement-in-cement technique

Surgical Technique. Hip System

Conversion total hip arthroplasty Functional outcome in Egyptian population

The Journal of Arthroplasty

The Journal of the Korean Society of Fractures Vol.16, No.1, January, 2003

Title component: minimum 9-year follow-up. The final publication is available

LIMITED INFLUENCE OF PROSTHETIC POSITION ON ASEPTIC LOOSENING OF THE SOUTER-STRATHCLYDE TOTAL ELBOW PROSTHESIS

Outcomes of Surgical Treatment of Periprosthetic Femoral Fractures in Cementless Hip Arthroplasty

INTRAMEDULLARY CANCELLOUS BONE BLOCK TO IMPROVE FEMORAL STEM FIXATION IN CHARNLEY LOW-FRICFION ARTHROPLASTY B. M. WROBLEWSKI, ADRIAN VAN DER RIJT

This publication is not intended for distribution in the USA.

Ten-year survival of the MS-30 matt-surfaced cemented stem

MINIMUM TEN-YEAR FOLLOW-UP OF COMPUTED TOMOGRAPHY BASED, CUSTOM CEMENTLESS STEM AFTER INTERTROCHANTERIC OSTEOTOMY FOR DYSPLASTIC HIPS

SUMMIT and DURALOC. Clinical Summary

Outcome of Surgical Treatment of AO Type C Pelvic Ring Injury

SURGICAL TECHNIQUE. Alpine Cemented Hip Stem

Bone Bangalore

Featuring. Technology. Product Rationale

Revision Total Hip Arthroplasty

Encina Taper Stem. Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

Centralization of the femoral component in cemented hip arthroplasty using guided stem insertion

DESIGN RATIONALE AND SURGICAL TECHNIQUE

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

Extended Trochanteric Osteotomy Followed by Cemented Impaction Allografting in Revision Hip Arthroplasty

R/F. Can T-smart Tomosynthesis Improve Diagnostic Accuracy on THA Component Stability? 1. Abstract

Hedrocel trabecular metal monoblock acetabular cups : mid-term results

Fixation and loosening of the cemented Müller straight stem

Bilateral total knee arthroplasty: One mobile-bearing and one fixed-bearing

Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

Stability without compromise. Epsilon Durasul Constrained Insert

Cotyloplasty in Cementless Total Hip Arthroplasty for an Insufficient Acetabulum

Socket wall addition device in the treatment of recurrent hip prosthesis dislocation

Measuring the Impact of Femoral Head Size on Dislocation Rates Following Total Hip Arthroplasty

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique

VerSys LD/Fx Cemented and Press-Fit Hip Prostheses. Surgical Technique IMAGE TO COME. Versatile solutions for total and partial hip replacement

Ito Hiroshi, Tanino Hiromasa, Yamanaka Yasuhiro, Minami Akio, Matsuno Tateo

Exeter. Designed for Anatomic Restoration. Clinical Evidence Education

A mechanical review of postoperative stem fractures of cemented total hip arthroplasty implants without femoral fracture

Templating and Pre Operative Planning 2. Preparation of the Acetabulum 4. Trial Sizing and Impaction of the Shell 5.

Case report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis?

Cementless Acetabular Fixation With and Without Screws

VERSYS HERITAGE REVISION HIP PROSTHESIS. Surgical Technique for Revision Hip Arthroplasty

Mid Term Results of Total Hip Arthroplasty for Various Hip Disorders

Femoral Revision in Hip Resurfacing Compared With Large-Bearing Metal-on-Metal Hip Arthroplasty

Exeter Contemporary Flanged Cup. Exeter. Providing Solutions

ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY

Aesculap Trilliance Triple Tapered Polished Hip Stem

AUTOBLOQUANTE AUTOBLOQUANTE. Product Rationale Surgical Technique

PRIMARY BIPOLAR ARTHROPLASTY IN TREATMENT OF UNSTABLE INTERTROCHANTERIC FRACTURES IN ELDERLY PATIENTS

Early results of Trabecular Metal augment for acetabular reconstruction in revision hip arthroplasty

Total Hip Arthroplasty around the Inception of the Interface Bioactive Bone Cement Technique

AGGRESSIVE GRANULOMATOUS LESIONS IN CEMENTLESS TOTAL HIP ARTHROPLASTY

The Basis CL cemented femoral stem: results after 8.9 years follow-up

A 42-year-old patient presenting with femoral

CORAIL HIP SYSTEM DESIGN RATIONALE

Collarless polished tapered stem

FIXATION FIRST WEAR REDUCTION OXIDATIVE STABILITY MECHANICAL INTEGRITY PROVEN TECHNOLOGY

Metha Short Hip Stem System

Transcription:

ORIGINAL ARTICLE Hip Pelvis 27(2): 83-89, 2015 http://dx.doi.org/10.5371/hp.2015.27.2.83 Print ISSN 2287-3260 Online ISSN 2287-3279 Long-term Outcome of Polished Stems in Total Hip Arthroplasty Jin-Young Park, MD, Hong-Joon Han, MD*, Seok-Jong Baik, MD, Suc-Hyun Kweon, MD Department of Orthopaedic Surgery, St. Carollo Hospital, Suncheon, Korea, Joint Replacement Center of Iksan Hospital, Iksan, Korea*, Department of Orthopedic Surgery, Wonkwang University College of Medicine, Iksan, Korea Purpose: The purpose of this study was to evaluate the clinical outcomes and radiologic findings of primary total hip arthroplasty (THA) using cemented polished femoral stems. Materials and Methods: We retrospectively reviewed 91 hips (91 patients) that had undergone primary THA with cemented polished femoral stems who were followed for at least 10 years. The mean age at surgery was 57 years (47-75 years). Mean follow up period was 12.8 years (10.1-14.0 years). Harris Hip Score (HHS) was used for clinical evaluation. Radiologic evaluation was focused on cementing technique including subsidence within the cement mantle, radiolucent lines at the cement-bone or cement-stem interface, cortical hypertrophy, and calcar resorption. Results: The average HHS was 55.2 points before the surgery that improved to an average of 93.2 points at the final follow-up. According to Barrack classification, there were 50, 32, and 9 cases in A, B, and C grades, respectively. Subsidence of femoral stem was less than 2 mm except in one patient. There were no progressing radiolucent line or loosening of the femoral stem. Conclusion: In this study, THA using cemented polished femoral stems was found to have favorable outcomes in long term follow-up. Key Words: Polished femoral stem, Osteolysis, Cement technique INTRODUCTION Early in the history of cemented stems in primary total Submitted: January 16, 2015 1st revision: March 4, 2015 2nd revision: April 5, 2015 Final acceptance: April 22, 2015 Address reprint request to Suc-Hyun Kweon, MD Department of Orthopedic Surgery, Wonkwang University Hospital, 895 Muwang-ro, Iksan 570-711, Korea TEL: +82-63-859-1367 FAX: +82-63-852-9329 E-mail: osksh@wonkwang.ac.kr This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons. org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. hip arthroplasty (THA), unfavorable clinical outcomes were often observed due to poor cementing techniques, materials (e.g., pre-coated stems) and design (collared) of artificial joints. It is reported that failure in surgeries might be caused by incomplete filling of bone cement in the femoral canal, surface treatment of cemented femoral stems that may result in osteolysis, and femoral stem designs that put excessive stress on the cement mantle 1-3). Subsequently, multiple studies demonstrated improved outcomes via enhancement of mechanical strength and reduction of stress on the cement mantle by using cement guns, vacuum mixing methods, and proximal/distal centralizers as well as improvement in design of femoral stems (e.g., polished, collarless, and double-tapered femoral stems) 4-6). However, there is little information available on the long-term follow-up Copyright c 2015 by Korean Hip Society 83

Hip Pelvis 27(2): 83-89, 2015 outcome of primary THA using cemented femoral stems in South Korea. In this study, we investigated the longterm outcome of primary THA using a femoral stems that are polished, collarless, and double-tapered. MATERIALS AND METHODS 1. Study Subjects We retrospectively reviewed 91 hips (91 patients) out of 125 hips (113 patients) who underwent primary THA with Exeter (Howmedica International Ltd., London, UK) femoral stems (Fig. 1) in our hospital between January 1993 and December 2003. Our patients constituted of 52 men and 39 women with an average age of 57 years (45-75 years). The shortest and longest follow-up durations were 10 years and 1 month, and 14 years, respectively. The mean follow-up duration was 12.8 years. Preoperative diagnoses included avascular necrosis (38 patients), Legg-Calve-Perthes disease (13 patients), developmental hip dysplasia (10 patients), primary osteoarthritis (5 patients), and femoral neck fracture (25 patients) (Table 1). 2. Surgical Methods The anterolateral approach (modified Hardinge) was used for operation. For the cementing technique, we used rasp to shape and fit the femoral marrow space and the loose cancellous bone in the proximal femur followed by pulsatile irrigation. A thin polyethylene suction pipe was inserted into the femoral marrow space and gauze soaked in hydrogen peroxide were packed to keep the area dry and prevent bleeding during the suction. After confirming the viscosity of cement, the gauze and the suction pipe were removed and the distal marrow space was blocked with an intramedullary plug. Retro-perfusion of the low-viscosity Simplex cement (Howmedica Osteonics Co., Rutherford, NJ, USA) was performed using a cement gun. After filling the proximal part with cement, the distal part of the cement gun was removed. An inverted triangle-shaped silicon was inserted and the proximal femoral part was sealed. Pressure was applied to get an even dispersion of the cement in the femoral marrow space. The Exeter femoral stem with a distal centralizer was inserted as depicted in Fig. 1. We did not use the vacuum mixing method in our patients. A cementless acetabular cup was used. CLS Expansion (Sulzer Orthopaedic, Barr, Switzerland), Osteolock (Howmedical Osteonics Co.), HGII (Zimmer, Warsaw, IN, USA), and Spherical (Osteonics, Allendale, NJ, USA) were used in 34, 23, 18, and 16 patients, respectively. Metal-polyethylene and zirconia- polyethylene were used for the articular surface in 76 and 15 patients, respectively. After surgery, patients completed femoral quadriceps and knee flexion exercises Table 1. Patient Demographic Characteristics Fig. 1. Exter femoral stem (Howmedica International Ltd. London, UK). Characteristic Data Age (yr) 57 (45-75) Sex (M:F) 52:39 Average follow-up period (yr) 12.8 Preoperative diagnosis (hip) Osteonecrosis 38 Fracture 25 LCP sequelae 13 Hip dysplasia 10 Osteoarthritis 05 Values are presented as median (range) or number only. M: male, F: female, LCP: Legg-Calve-Perthes disease. 84 www.hipandpelvis.or.kr

Jin-Young Park et al. Long-term Outcome of Polished Stems in Total Hip Arthroplasty for 3-5 days followed by 5-7 days of wheelchair assisted walking. Up to the 6th week, partial weight bearing was allowed and full weight bearing was achieved with gradual increment of the weight load. 3. Experimental Methods Harris Hip Score (HHS) 7) was used for clinical evaluation. Patients were grouped as excellent, good, normal, and poor in >90, 80-89, 70-79, and <69 HHSs, respectively. We used anteroposterior and lateral images for radiologic evaluation of hips at the time of operation and throughout the final follow-up. Barrack classification 1) was used for postoperative cementing technique evaluation that categorizes the patients into four grades. We measured the vertical distance of the radiolucent line of the outer shoulder of stem in zone 1 to assess subsidence of the femoral stem 8). When we could not measure this distance, the change in the distance between the end of the femoral stem and the lower part of the distal centralizer was assessed (Fig. 2). As described by Gruen et al. 9), the femoral stem is divided into 7 zones for monitoring and the radiolucent line is identified if the demarcation line of bone cement and femoral stem is thicker than 2 mm. Loosening of the femoral stem is classified as Definite Loosening, Probable Loosening, or Possible Loosening according to the classification of Harris et al. 10). We also monitored the reduction in height of the medial femoral neck (calcar) and the changes in erosion and cyst thereof. Localized endosteal bone lysis and femoral cortical hypertrophy were also analyzed. As described previously by DeLee and Charnley 11), an acetabular cup is divided into 3 zones and the radiolucency between bone and the acetabluar cup is monitored along with osteolysis. We evaluated the stability of the acetabular cup according to the method of Massin et al. 12) where the loosening of the acetabular cup is defined as 1) more than 5 mm displacement in radiologic images or 2) appearance of radiolucent lines including the acetabular screws. We used Spearman correlation coefficient to find out the association between postoperative complication and Barrack s classification against HHS. Clinical failure was defined as reoperation due to 1) loosening of acetabular cup, 2) loosening of femoral stem, and 3) any other clinical reasons (periprosthetic fracture, recurrent dislocation) by the end of the follow-up. The Kaplan-Meier survival analysis was performed using the SPSS program ver 12.0 (SPSS Inc., Chicago, IL, USA) 13). RESULTS The average HHS was 55.2 (19-82) before the surgery that improved to an average of 93.2 (78-100) at the final follow-up. Excellent and good outcomes were found in 75 (82.4%) and 12 (13.2%) patients, respectively with only 4 (4.4%) patients in the normal group (Table 2). In postoperative imaging, 50 (54.9%) and 32 (35.2%) patients were classified as grade A and grade B, respectively, according to the Barrack classification. We A B Fig. 2. Radiologic parameters about subcidence of femoral stem (red arrows at the proximal femoral shoulder and red lines in the distal centralizer). www.hipandpelvis.or.kr 85

Hip Pelvis 27(2): 83-89, 2015 identified nine patients as grade C and no one as grade D (Table 3). The average subsidence of femoral stem was 1.9 mm (0.5-4.9 mm) at the final follow-up with no subsidence of bone cement in any case. Only one patient possibly had loosening of femoral stem on the final follow-up imaging who was categorized as grade C. Four patients had less than 2-mm reduction in height of medial femoral neck at the final follow-up. Three patients had femoral cortical hypertrophy. Loosening of the acetabular cup was found in 13 patients. Revision of the acetabular cup was performed in 9 patients (9.9%). Others were monitored without revision. We did not find osteolysis and loosening of the femoral stem in any patient (Fig. 3). Postoperative complications included fracture of the proximal part of the femoral stem due to falling (3 patients, Vancouver type C), fracture of the femoral stem due to an unknown reason (1 patient), and recurrent dislocation due to improper positioning of the acetabular cup (2 patients). Proximal femoral stem fractures were managed with inner fixation using a metal plate with replacing a same size stem while maintaining the cement. The two patients with recurrent dislocation underwent revision of acetabular cup. Barack classification did not significantly influence the HHS yet it was shown to be significantly lower in patients with either loosening of the acetabular cup or postoperative complications (Table 4). The Kaplan- Meier survival analysis revealed 84.6% survival rate for a total of 124 hips over 12.8 years of follow-up including 34 hips lost to follow-up (Fig. 4). Table 2. Comparison of Preoperative and Postoperative Harris Hip Scores (HHS) Variable Data Preoperative HHS 55.2 (19-82). Last follow-up HHS.93.2 (78-100) Distribution of score Excellent (>90) 75 (82.4). Good (80-89) 12 (13.2). Fair (70-79) 4 (4.4). Poor (<69) 00 (0)00.. Values are presented as median (range) or number (%). Table 3. Radiological findings indicating cement filling in the postoperative X-ray Variable Data Subsidence (mm) 1.9 (0.5-4.9) Cement grade* Grade A 50 Grade B 32 Grade C 09 Grade D 00 Values are presented as median (range) or number only. *Based on Barrack s classification. A B C Fig. 3. (A) This anteroposterior radiography shows Legg-Calve-Perthes disease sequalae of femoral head in a 58-year-old male. (B) The postoperative radiography shows good cement mantle (Barrck grade A). (C) After 12.4 years, the radiography shows subsidence less than 1 mm of femoral stem and no osteolysis around acetabular and femoral component. 86 www.hipandpelvis.or.kr

Jin-Young Park et al. Long-term Outcome of Polished Stems in Total Hip Arthroplasty Table 4. Correlation of Harris Hip Score (HHS) and Barrack s Classification, Complications Variable (n) HHS P-value Barrack s classification 92.7 (86-97)0 0.523 A (50) B (32) 93.1 (87-100) C (09) 91.9 (85-98)0 Acetabular aceptic loosening (9) 82.3 (79-88)0 <0.05 Periprosthetic or stem fracture (4) 80.5 (78-82)0 <0.05 Reccurent dislocation (2) 79.0 (78-80)0 <0.05 Values are presented as median (range). Fig. 4. At the mean follow-up (F/U) 12.8 years, the survival rate was 84.6% by Kaplan-Meier. THA, total hip arthroplasty. DISCUSSION In this study, we investigated long-term clinical outcome of polished femoral stems in primary THA and found favorable outcomes from both clinical and radiologic aspects. Unlike other cement stems, the polished femoral stem (0.1μm Ra) is debonded from the bone cement and shifts toward the axis creating subsidence in the bone cement. Subsidence is mechanically critical and potentially results in favorable clinical outcomes as it contributes to improved femoral stem stability in bone cement through hoop stress. In early bone cementing surgeries, however, 30-40% failure rate was demonstrated for primary THA in longterm follow-ups (10 years) with the failure rate being 15% in 20-year follow-ups. Such failures might be due to poor cementing technique(s), surface treatments for the femoral stems, and their designs 14-16). The early cementing technique is known to have poor clinical outcomes and failure as it inserts the femoral stem despite incomplete marrow filling with bone cement. This happens due to either non-sufficient bone cement filling or presence of debris and excessive removal of cancellous bone from the proximal femoral canal, followed by bleeding in the marrow space that gives rise to an inconsistent thickness in cement mantle, which should be at least 2 mm 4). Barrack et al. 1) claimed no loosening of the femoral stem in their 12-year radiographic review on second generation cementing techniques (e.g., use of a methylmethacrylate femoral medullary plug, delivery of a doughy mix of cement using a gun, and pulsatile irrigation). Kim et al. 5) also reported excellent clinical www.hipandpelvis.or.kr 87

Hip Pelvis 27(2): 83-89, 2015 outcomes in their 2-year follow-up of fourth generation cementing techniques (vacuum mixing method and use of proximal and distal centralizers). We implemented the second generation cementing techniques along with the use of distal centralizers in all patients. In addition, in order to achieve excellent filling of bone cement in the distal femoral part, silicon plugs were used to seal the proximal femoral part, and pressurized bone cement was filled using a cement gun 16). This resulted in the absence of a radiographic postoperative boundary line between the bone cement and the femoral cortex (aka white out ). In our nine patients who were categorized as grade C in Barrack classification, we did not find a failure in the femoral stem, which shows that the cementing technique did not attribute to this outcome. Rather, these patients were osteoporotic who are characterized by a wide marrow space and non-sufficient cancellous bone, which might have resulted in the distal dislocation of the femoral medullary plug under pressure. Surface treatment of the femoral stem is controversial. In earlier national and international studies, favorable outcomes were shown with precoated or rough surface femoral stems. Most failures were shown in bone cement thickness of below 1 mm (C2), which is a result of poor cementing technique 17-20). However, in a few investigations, higher risks of loosening of stem and osteolysis were reported with rough or precoated femoral stems, hence, polished femoral stems were recommended 21-23). This could be due to short life of binding between the femoral stem and the bone cement that could not last over the follow-up. In addition, debonding is unavoidable with rough and precoated stems, which eventually exacerbates the stress over the bone cement and increases the likelihood of debris formation that can facilitate osteolysis via abrasion of the bone cement. There are a few studies on polished femoral stems in South Korea. Shon et al. 24) and Yim et al. 25) followed up patients receiving polished femoral stems for over 5 years and did not find any aseptic loosening of femoral stem. Similarly, in the present study, we did not find aseptic loosening of the femoral stem while the subsidence of the femoral stem was approximately 1.9 mm (0.5-4.9 mm) in our 10-year follow-up. Polished femoral stems are present in a separate form from the bone cement, which allows subsidence of the femoral stem in the cement. This may result in stress relaxation that relieves the stress on the bone cement. Carrington et al. 26) showed reduction in the height of the medial femoral neck after implementation of bone cement in primary THA. The authors claimed that the reduction might be due to incomplete transfer of stem weight to the distal femur yet no association might exist with aseptic loosening. In our study, we had four patients with reduction in the height of the medial femoral neck but no loosening of stem was observed. Cortical hypertrophy develops due to the weight load on the femoral stem on the proximal part of the femur. Particularly, it happens with large-sized femoral stems. However, subsidence of stem may be unrelated to cortical hypertrophy 26). We had three patients with cortical hypertrophy who had the stem size of No 3 yet, subsidence was found to be less than 1 mm in these patients. Subsidence of the femoral stem transfers the hoop stress to bone and minimizes the stress shield. In our patients, cortical hypertrophy might be caused by imbalanced transfer of stress. In patients undergoing revision of acetabular cup (9 patients), two had CLS expansion and three had Osteolock. HGII was used in three patients and one had received Spherical. Metal-polyethylene was the material of the articular surface in all nine patients. It appears that the position, direction of cup, and combination of the articular surface may elicit a more pronounced effect on the clinical and radiologic outcomes rather than the various type of the acetabular cup. There are a number of limitations in our study. We retrospectively reviewed clinical and radiologic outcomes without having a matching control group. In addition, we did not include other potential factors that might have influenced the outcome including the position of the acetabular cup, size of the femoral head, degree of abrasion of the articular surface, patients age, and physical activities. CONCLUSION In our study, we found favorable outcomes with polished femoral stems for primary THA in a 10-year follow-up. This might be due to debonding between the stem and the bone cement. This creates the hoop stress in bone and contributes to improved stability of the femoral stem. Therefore, THA using cemented polished femoral stems was found to have favorable outcomes in long term follow-up. 88 www.hipandpelvis.or.kr

Jin-Young Park et al. Long-term Outcome of Polished Stems in Total Hip Arthroplasty REFERENCES 01.Barrack RL, Mulroy RD Jr, Harris WH. Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. A 12-year radiographic review. J Bone Joint Surg Br. 1992;74:385-9. 02.Sherfey JJ, McCalden RW. Mid-term results of Exeter vs Endurance cemented stems. J Arthroplasty. 2006;21:1118-23. 03. Mohler CG, Callaghan JJ, Collis DK, Johnston RC. Early loosening of the femoral component at the cement-prosthesis interface after total hip replacement. J Bone Joint Surg Am. 1995;77:1315-22. 04. Mulroy WF, Estok DM, Harris WH. Total hip arthroplasty with use of so-called second-generation cementing techniques. A fifteen-year-average follow-up study. J Bone Joint Surg Am. 1995;77:1845-52. 05.Kim SY, Baek SH, Park IH, et al. Early results of hybrid total hip arthroplasty using a fourth generation cementing technique. J Korean Hip Soc. 2003;15:209-16. 06.Williams HD, Browne G, Gie GA, Ling RS, Timperley AJ, Wendover NA. The Exeter universal cemented femoral component at 8 to 12 years. A study of the first 325 hips. J Bone Joint Surg Br. 2002;84:324-34. 07.Harris WH, Maloney WJ. Hybrid total hip arthroplasty. Clin Orthop Relat Res. 1989;249:21-9. 08.Fowler JL, Gie GA, Lee AJ, Ling RS. Experience with the Exeter total hip replacement since 1970. Orthop Clin North Am 1988;19:477-89. 09. Gruen TA, McNeice GM, Amstutz HC. Modes of failure of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res. 1979;141:17-27. 10. Harris WH, McCarthy JC Jr, O Neill DA. Femoral component loosening using contemporary techniques of femoral cement fixation. J Bone Joint Surg Am. 1982;64:1063-7. 11.DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976;121:20-32. 12. Massin P, Schmidt L, Engh CA. Evaluation of cementless acetabular component migration. An experimental study. J Arthroplasty. 1989;4:245-51. 13.Kaplan EL, Meier P. Nonparametric estimation from incomplete observations. J Am Stat Assoc. 1958;53:457-81. 14.Beckenbaugh RD, Ilstrup DM. Total hip arthroplasty. J Bone Joint Surg Am. 1978;60:306-13. 15.Stauffer RN. Ten-year follow-up study of total hip replacement. J Bone Joint Surg Am. 1982;64:983-90. 16.Sutherland CJ, Wilde AH, Borden LS, Marks KE. A tenyear follow-up of one hundred consecutive Müller curvedstem total hip-replacement arthroplasties. J Bone Joint Surg Am. 1982;64:970-82. 17.Schulte KR, Callaghan JJ, Kelley SS, Johnston RC. The outcome of Charnley total hip arthroplasty with cement after a minimum twenty-year follow-up. The results of one surgeon. J Bone Joint Surg Am. 1993;75:961-75. 18.Oh I, Bourne RB, Harris WH. The femoral cement compactor. An improvement in cementing technique in total hip replacement. J Bone Joint Surg Am. 1983;65:1335-8. 19.Shon WY, Hur CY, Moon JG, Nam HW, Lee YK, Choi JH. 3-5 years results of cemented Versys-TM femoral stem. J Korean Hip Soc. 2004;16:317-23. 20. Suh DH, Yun HH, Chun SK, Shon WY. Fifteen-year results of precoated femoral stem in primary hybrid total hip arthroplasty. Clin Orthop Surg. 2013;5:110-7. 21. Harris WH. Long-term results of cemented femoral stems with roughened precoated surfaces. Clin Orthop Relat Res. 1998;355:137-43. 22. Sporer SM, Callaghan JJ, Olejniczak JP, Goetz DD, Johnston RC. The effects of surface roughness and polymethylmethacrylate precoating on the radiographic and clinical results of the Iowa hip prosthesis. A study of patients less than fifty years old. J Bone Joint Surg Am. 1999;81:481-92. 23.Collis DK, Mohler CG. Comparison of clinical outcomes in total hip arthroplasty using rough and polished cemented stems with essentially the same geometry. J Bone Joint Surg Am. 2002;84-A:586-92. 24.Shon WY, Hur CY, Moon JG, Han SW, Yang JH, Jang KM. 2-5 year results of the cemented polished Versys Heritage femoral stem. J Korean Orthop Assoc. 2008;43: 9-16. 25.Yim SJ, Woo SH, Kim MY, et al. Total hip arthroplasty using Exeter stem. J Korean Hip Soc. 2005;17:195-200. 26. Carrington NC, Sierra RJ, Gie GA, Hubble MJ, Timperley AJ, Howell JR. The Exeter Universal cemented femoral component at 15 to 17 years: an update on the first 325 hips. J Bone Joint Surg Br. 2009;91:730-7. www.hipandpelvis.or.kr 89

Hip Pelvis 27(2): 83-89, 2015 90 www.hipandpelvis.or.kr