Verification of relative output factor measurement using Gafchromic films for small-field radiosurgery photon beams.

Similar documents
Verification of Relative Output Factor (ROF) Measurement for Radiosurgery Small Photon Beams

Calibration of dosimeters for small mega voltage photon fields at ARPANSA

Radiochromic film dosimetry in water phantoms

ROPES eye plaque dosimetry: commissioning and verification of an ophthalmic brachytherapy treatment planning system

Topics covered 7/21/2014. Radiation Dosimetry for Proton Therapy

Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies

A comparison of dose distributions measured with two types of radiochromic film dosimeter MD55 and EBT for proton beam of energy 175 MeV

Basic dosimetric data for treatment planning system

The Journey of Cyberknife Commissioning

Multilayer Gafchromic film detectors for breast skin dose determination in vivo

DOSIMETRIC COMPARISION FOR RADIATION QUALITY IN HIGH ENERGY PHOTON BEAMS

Dosimetric characterization of surface applicators for use with the Xoft ebx system

Two-Dimensional Thermoluminescence Dosimetry System for Proton Beam Quality Assurance

Phantom Positioning Variation in the Gamma Knife Perfexion Dosimetry

tsmall FIELD DOSE CALIBRATIONS WITH GAFCHROMIC FILM

A preliminary clinic dosimetry study for synchrotron radiation therapy at SSRF

Y FILMS DOSIMETR Nederland België / Belgique

Verification of treatment planning system parameters in tomotherapy using EBT Radiochromic Film

Small Field Dosimetry: Overview of AAPM TG-155 and the IAEA-AAPM Code of Practice (Therapy)

Mania Aspradakis John Byrne Hugo Palmans John Conway Jim Warrington Karen Rosser Simon Duane

Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy

Hot Topics in SRS: Small Field Dosimetry & Other Treatment Uncertainties. Sonja Dieterich, PhD University of California Davis

Plan-Specific Correction Factors for Small- Volume Ion Chamber Dosimetry in Modulated Treatments on a Varian Trilogy

Limits of Precision and Accuracy of Radiation Delivery Systems

CALCULATION OF BACKSCATTER FACTORS FOR LOW ENERGY X-RAYS USING THE TOPAS MONTE CARLO CODE

Absorbed Dose Response in Water of Kilovoltage X-rays Beams of Radiochromic Film and Thermoluminescent for Brachytherapy Dosimetry

Inhomogeneity effect in Varian Trilogy Clinac ix 10 MV photon beam using EGSnrc and Geant4 code system

Small Field Dosimetry: Overview of AAPM TG-155 and the IAEA-AAPM Code of Practice (Therapy) What is a Small Field? Indra J. Das/ Small Fields (Page-1)

MEASUREMENT OF TMR AND PDD PROFILES IN SMALL FIELDS. SB Crowe, E Whittle, C Jones, T Kairn

Monte Carlo simulation of 192 Ir radioactive source in a phantom designed for brachytherapy dosimetry and source position evaluation.

Assessment of Dosimetric Functions of An Equinox 100 Telecobalt Machine

Small field diode dosimetry

Applications in brachytherapy

Patient dosimetry for total body irradiation using single-use MOSFET detectors

Can we hit the target? Can we put the dose where we want it? Quality Assurance in Stereotactic Radiosurgery and Fractionated Stereotactic Radiotherapy

3D printing of air slab caps for correction free small field dosimetry. Benjamin Perrett, Paul Charles, Tim Markwell, Tanya Kairn, Scott Crowe

Disclosure. Outline. Machine Overview. I have received honoraria from Accuray in the past. I have had travel expenses paid by Accuray in the past.

Comparison of microlion liquid filled ionisation chamber with Semiflex and Pinpoint air filled chambers

Diode calibration for dose determination in total body irradiation

Film-based dose validation of Monte Carlo algorithm for Cyberknife system with a CIRS thorax phantom

IMRT point dose measurements with a diamond detector

4 Essentials of CK Physics 8/2/2012. SRS using the CyberKnife. Disclaimer/Conflict of Interest

Evaluation of Dosimetric Characteristics of a Double-focused Dynamic Micro-Multileaf Collimator (DMLC)

On the impact of ICRU report 90 recommendations on k Q factors for high-energy photon beams

How accurately can we measure dose clinically? Accurate clinical dosimetry. Dosimetric accuracy requirement

Small field detector correction factors: effects of the flattening filter for Elekta and Varian linear accelerators

Monte Carlo water-equivalence study of two PRESAGE formulations for proton beam dosimetry

PMP. Use of Cylindrical Chambers as Substitutes for Parallel- Plate Chambers in Low-Energy Electron Dosimetry. Original Article.

Dosimetric study of 2D ion chamber array matrix for the modern radiotherapy treatment verification

Much of what we will say

Energy response of EBT3 radiochromic films: implications for dosimetry in kilovoltage range

Quality Assurance of a 50-kV Radiotherapy Unit Using EBT3 GafChromic Film: A Feasibility Study

Evaluation of a single-scan protocol for radiochromic film dosimetry

GAFCHROMIC DOSIMETRY MEDIA TYPE MD-V3

Optimization of the T2 parametric image map calculation in MRI polymer gel dosimetry

Manik Aima, Larry A. DeWerd, Wesley S. Culberson

Australian Journal of Basic and Applied Sciences. Evaluation of CT based MAGAT gel dosimetry system for measuring 3D dose distribution

Detectors assessment for stereotactic radiosurgery with cones

IAEA-CN THE ESTRO-EQUAL RESULTS FOR PHOTON AND ELECTRON BEAMS CHECKS IN EUROPEAN RADIOTHERAPY BEAMS*

Activity report from JCOG physics group

Diode Dosimetric Characteristics Assessment for In-Vivo Dosimetry in Radiotherapy Treatment

Measurement of Dose to Implanted Cardiac Devices in Radiotherapy Patients

Protons Monte Carlo water-equivalence study of two PRESAGE formulations for proton beam dosimetry J. Phys.: Conf. Ser.

Semiflex 3D. Always perfectly oriented. 3D Thimble Ionization Chamber for Relative and Absolute Dosimetry

Applications of Monte Carlo simulations to radiation dosimetry

Advanced film dosimetry for a UK brachytherapy audit

Out-of-field doses of CyberKnife in stereotactic radiotherapy of prostate cancer patients

Verification of the PAGAT polymer gel dosimeter by photon beams using magnetic resonance imaging

Calibration of TLD700:LiF for Clinical Radiotherapy Beam Modalities & Verification of a High Dose Rate Brachytherapy Treatment Planning System

Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy

M. J. Maryanski, Three Dimensional BANG Polymer Gel Dosimeters AAPM'99, CE Course

Dosisverifikation mit Delta 4 Discover während der Behandlung

8/2/2018. Disclosures. In ICRU91: SRT = {SBRT/SABR, SRS}

Small Field Dosimetry & Radiochromic film

EXPERIMENTAL RESULTS IN PERCENTAGE DEPTH DOSE (PDD) DETERMINATION AT THE EXTENDED DISTANCES *

LONG TERM STABILITY OF THE PERFORMANCE OF A CLINICAL LINEAR ACCELERATOR AND Z-SCORE ASSESSEMENT FOR ABSORBED DOSE TO WATER QUANTITY

Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

STEREOTACTIC DOSE VERIFICATION PHANTOM VERSATILE STEREOTACTIC QA PHANTOMS

Measurement of computed tomography dose profile with pitch variation using Gafchromic XR-QA2 and thermoluminescence dosimeter (TLD)

Verification of micro-beam irradiation

PROCEDURE FOR ABSORBED DOSE TO WATER DETERMINATION IN HIGH ENERGY PHOTON AND ELECTRON BEAMS BY FERROUS SULPHATE DOSIMETER AT INMRI-ENEA

An Independent Audit and Analysis of Small Field Dosimetry Quality Assurance. David Followill IROC Houston QA Center

S. Derreumaux (IRSN) Accidents in radiation therapy in France: causes, consequences and lessons learned

The use of radiographic film for linear accelerator stereotactic radiosurgical dosimetry

Production and dosimetry of simultaneous therapeutic photons and electrons beam by linear accelerator: a monte carlo study

Practical Reference Dosimetry Course April 2015 PRDC Program, at a glance. Version 1.0. Day 1 Day 2 Day 3 Day 4

Semiflex 3D. Always perfectly oriented. 3D Thimble Ionization Chamber for Relative and Absolute Dosimetry

A model for assessing VMAT pre-treatment verification systems and VMAT optimization algorithms

IAEA/AAPM Code of Practice for the Dosimetry of Static Small Photon Fields. Jan Seuntjens McGill University Montréal, Canada

PRECISE DOSIMETRY OF SMALL PHOTON BEAMS COLLIMATED BY AN ADD-ON DYNAMIC MICRO-MULTILEAVES COLLIMATOR.

Small Field Dosimetry Issues: Theory, Calibration and Treatment Planning

Eric E. Klein, Ph.D. Chair of TG-142

ABSTRACTS FOR RADIOTHERAPY STANDARDS USERS MEETING. 5 th June 2007

How accurately can we measure dose clinically? Dosimetric accuracy requirement. Accurate Clinical dosimetry. Part I: Fundamentals and Issues

Patient-specific quality assurance for intracranial cases in robotic radiosurgery system

MAX-HD SRS PHANTOM THE COMPREHENSIVE END-TO-END SRS PHANTOM SCAN PLAN LOCALIZE TREAT. distributed by:

Amendment No. 2. Item No. 2 (Rfx/ Event number )

In vivo dosimetry and shielding disk alignment verification by EBT3 GAFCHROMIC film in breast IOERT treatment

Verification of performance of Acuros XB Algorithm (AXB) Implemented on Eclipse Planning System

SRS/SBRT Errors and Causes

Transcription:

IOP Conference Series: Materials Science and Engineering PAPER OPEN ACCESS Verification of relative output factor measurement using Gafchromic films for small-field radiosurgery photon beams. To cite this article: R Abdullah et al 2018 IOP Conf. Ser.: Mater. Sci. Eng. 298 012022 View the article online for updates and enhancements. This content was downloaded from IP address 148.251.232.83 on 04/07/2018 at 12:00

Verification of relative output factor measurement using Gafchromic films for small-field radiosurgery photon beams. R Abdullah 1, 4, M S Sapeei 1, N S A Shukor 1, M F M Yusof 1, M Mohamed 2, 3, N R N Idris 2, 3, A L Yusoff 2, 3, A Zakaria 1, and M Z A Aziz 4 1 School of Health Sciences, Health Campus USM, Universiti Sains Malaysia, Kelantan, Malaysia 2 Department of Nuclear Medicine, Radiotherapy, and Oncology, School of Medical Sciences, Health Campus USM, Universiti Sains Malaysia, Kelantan, Malaysia 3 Department of Nuclear Medicine, Radiotherapy, and Oncology, Hospital Universiti Sains Malaysia, Kelantan, Malaysia. 4 Advanced Medical and Dental Institute, Universiti Sains Malaysia, Bertam, Pulau Pinang, Malaysia. reduan@usm.my Abstract. Accurate dosimetry of small-field photon beams has always been difficult to achieve, due to the steep dose gradient and absence of lateral electronic equilibrium. The purpose of this study was to verify the measurement of relative output factor (ROF), which is one of the dosimetric parameter required for stereotactic radiosurgery (SRS) treatment planning. The ROFs for Radionics circular cone collimators with diameter in the range of 10.0 to 45.0 mm were measured using Gafchromic EBT2 and EBT3 films. The measurements were then compared with the ROFs obtained using a PinPoint ionisation chamber and Monte Carlo (MC) simulation. From the results, the ROFs measured by the ionisation chamber, EBT2, and EBT3 films were good agreement with the MC simulation, with deviations of less than 1.5, 2.6, and 5.0 % respectively. Based on the film dosimetry, the EBT2 film showed in a more reliable measurement for field size ranging from 15.0 to 45.0 mm, compared with EBT3. As a conclusion, based on the special characteristic of the small-field photon beams, ROF measurement using PinPoint ionisation chamber are being favoured, due to its accuracy. However, the EBT2 film can be used as an alternative, when high spatial resolution is required. 1. Introduction In order for a stereotactic radiosurgery (SRS) treatment planning system (TPS) to be commissioned to work with a medical linear accelerator (LINAC), a large number of measurements using the LINAC will be required, to be entered into the system. One of the parameters to be measured is the relative output factor (ROF). The ROF is a simple way of comparing the output of a LINAC under desired settings, to the output of the same LINAC under reference condition (i.e. field size of 10 x 10 cm 2 at the reference depth inside a water phantom, and source to surface distance (SSD) of 100 cm), with known absolute dose. The ROFs need to be accurately measured for very small field size, as it can be Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. Published under licence by Ltd 1

used to tell the TPS how the LINAC output varies as the field size reduces, allowing a more accurate calculation of the dose. The accuracy of the ROF directly affects the accuracy of the dose delivered in a radiosurgical treatment [1]. Accurate measurement of the ROF for small-field photon beams ( 4 x 4 cm 2 ) used in SRS can be made difficult due to the presence of lateral electronic disequilibrium and steep dose gradients. The ionisation chamber is a standard dosimeter used for measuring the dosimetric parameters of photon beams, such as percentage depth dose (PDD) beam profiles, and ROF. However, for small-field photon beams, several challenges are present, as discussed in the published literatures [2-4]. Various dosimeters can be used as alternative to the ionisation chamber, e.g., diode, diamond detector, thermoluminiscent detector (TLD), metal-oxide-semiconductor field effect transistor (MOSFET), glass rod dosimeter (GLD), radiographic, and radiochromic films. Each dosimeter has its own pros and cons when it is used for the small-field photon beams, as elaborated in the published literatures [5-10]. To date, there is no single detector which can be used on its own, a narrow circular field (with diameter of 20 mm) [11]. This led to many relying on the Monte Carlo (MC) simulation. Although the MC calculation is still considered as an experimental method, it is often used as a detector-independence reference. The relative performance of each detector can therefore be quantified, as deviation from the MC simulation results. Therefore, the ROFs of small-filed photon beams can be obtained, through careful comparison between the ROFs estimated by the small volume ionisation chamber, film dosimetry, and MC simulation. This study was conducted to compare the measured ROF using two different types of Gafchromic film (i.e. EBT2 and EBT3) and a PinPoint ionisation chamber, and validated using MC simulation. 2. Material and methods All irradiations were performed with 6 MV photon beam, using a LINAC (PRIMUS, Siemens Healthineers, Erlangen, Germany) equipped with a multi-leaf collimator (MLC). The LINAC output was calibrated based on the IAEA TRS-398 protocol [12]. The ROF for circular cone collimators (Radionics, Integra Radionics, Massachusetts, USA) with diameters of 10.0, 15.0, 20.0, 22.5, 27.5, 32.5, and 45.0 mm, were measured in this study. 2.1. Measurement of ROF using PinPoint Ionisation Chamber The measurement of ROF using an ionisation chamber (PinPoint, PTW, Freiburg, Germany) with vented sensitive volume of 0.015cm 3, was conducted by placing it inside a water scanning system (MP3, PTW, Freiburg, Germany). The ionisation chamber was placed at the centre of a 45.0 mm circular field size, depth of maximum dose (dmax) of 1.5 cm and SSD of 100 cm. the procedure was repeated by replacing the circular cone collimator with that of a different diameter. The ROF for each circular cone collimator was calculated, by calculating the ratio of the charge obtained at dmax ( w, ic, A), to the charge ontained at similar depth with 10 x 10 cm 2 or reference field size ( w, ic, r ). The ROFs were calculated using Equation 1, as follows: R F A = Cw,ic,A Cw,ic,r (1) 2.2. Film calibration Gafchromic EBT2 films (Ashland Inc., Kentucky, USA) were irradiated with 6 MV photon beam, by placing it inside a 30 x 30 x 20 cm3 solid water phantom (RW3, PTW, Freiburg, Germany), at the centre of a 10 x 10 cm2 field size, dmax of 1.5 cm and SSD of 100 cm. Film calibration was carried out by placing the film perpendicular to the beam, for dose ranging from 50 to 500 cgy. Unexposed film was also developed, to obtain the background reading. After 24 hours, the calibrated films were scanned using a flatbed scanner (Epson Expression 10000XL, Seiko Epson Corporation, Nagano, Japan) in landscape orientation. The ratio of film response to the dose delivered was determined in 2

pixel value, using a patient plan verification software (Verisoft, PTW, Freiburg, Germany). Equation 2 was used to convert pixel value to the net optical density (OD). Similar procedure was repeated for the EBT3 film (Ashland Inc., Kentucky, USA). Finally, a calibration curve (dose versus net OD) was generated for each film type, i.e. EBT2 and EBT3 films. t = Lo ix a irra ia i ix a irra ia i (2) 2.3. Measurement of ROF using Gafchromic EBT2 and EBT3 films Gafchromic films (i.e. EBT2 and EBT3) taken from the same batch as the calibrated films, were irradiated with 6 MV photon beam, by placing it inside the 30 x 30 x 20 cm 3 solid water phantom, at the centre of a 45.0 mm circular field size, dmax of 1.5 cm and SSD of 100 cm. the procedure was repeated by replacing the circular cone collimator with that of a different diameter. The irradiated films were scanned using the EPSON flatbed scanner, at 24 hours post-irradiation and analysed using Verisoft software. The net OD was converted to dose, based on calibration curve. The ROF for each circular cone collimator was calculated, by calculating the dose obtained at dmax, to the dose obtained at similar depth with 10 x 10 cm 2 field size. 2.4. Modelling and simulation The ROF for the Radionics circular cone collimators were calculated using BEAMnrc and DOSXYZ nrc software components, which are included in the EGSnrc source code (national Research Council Canada, NRCC). The code was installed on a personal desktop computer. The BEAmnrc is a general purpose MC simulation system for modelling of radiotherapic source, while DOSXYZnrc is used to calculate the dose in three dimensional (3D) medium [13]. The simulations were performed in three stages. For the first stage, the BEAMnrc was used to simulate the PRIMUS LINAC head, to obtain the phase space data for the first 20 cm distance after target (right after the projection mirror). This phase space file was used for the subsequent circular and square (10 x10 cm 2 ) field sizes. In this stage, 50 million particle histories were used. For the second stage, all circular cone collimators used in this study were simulated. The collimators were simulated as stainless steel materials with a density of 8.03g/cm 3. The geometry of each collimator was simulated based manual measurement, since technical drawing of the component was unavailable. The radionics assembly holder and circular cone collimators were simulated using the BEAMnrc s flattening filter (FLATFILT) component module. The 50 x 50 mm 2 (phase space file was used for second stage) and space files were generated for all cone collimators, at SSD of 80 cm. The energy cut-off values for photon (PCUT) and electron (ECUT) transport were set to 0.01 and 0.70 MeV, respectively. The phase space files generated during the second stage of the simulations were used in the final stage, to calculate the 3D dose distributions in water phantom using the DOSXYZnrc software. 3. Results and Discussion Figure 1 shows the calibration curves of the EBT2 and EBT3 films, following irradiation with 6 MV photon beam. Both films showed linear response to the dose. Based on the R 2 values, EBT3 showed a more linear response to the dose ranging from 50 to 250 cgy, compared to the EBT2 film. The differences between the films were smaller than ~ 4 %, with almost similar sensitometric curve pattern. In general, the results showed no significant variation in terms of dose response, for both films. However, the variations in sensitivity (net OD per unit dose) may be present, when different batches of film were used. This has been proven in the study done by Butson et al. (2010), where it was concluded that there were variations in the sensitivity between different batches of each film (i.e. EBT2 and EBT3), although both batches possess similar thickness of active layer (~ 28 µm) [5]. Hence, the EBT2 and EBT3 films must be calibrated, every time a set of measurement needs to be performed using films from different batches. 3

300 Dose (cgy) 250 200 150 100 50 R² = 0.9918 R² = 0.9898 EBT3 EBT2 0 0 0.05 0.1 0.15 Net OD Figure 1. Dose (cgy) versus net OD for Gafchromic EBT2 and EBT3 films. The comparison between the ROFs measured using the PinPoint ionisation chamber, EBT2 and EBT3 films with respect to the MC calculated ROF, are shown in Table 1 and 2. The ROFs measured using the ionisation chamber were in excellent agreement with the MC calculated ROFs (with less than 1.5 % deviation, except for the 10 mm circular collimator. The accuracy of the ionisation chamber in small-field photon beam measurement was dependent on the resolution of the ionisation chamber. A smaller sensitive volume will contribute to higher resolution. The ROFs measured using the EBT2 and EBT3 films were also found to be in good agreement with the MC-calculated ROFs (with deviations of less than 2.6 and 5.0 %, respectively), except for 10 mm circular collimator. The results were in parallel with the study done by Underwood (2013), which reported the inherent variations in dose measurement of around 2 to 5 % (for both EBT2 and EBT3 films), even with an optimised dosimetric process [14]. Table 1. The ROFs obtained using the films (EBT2 and EBT3), ionization chamber (PP), and MC simulation, for different circular cone diameters. Cone (mm) ROF EBT2 EBT3 PP MC 10.0 0.616 0.625 0.733 0.770 15.0 0.829 0.833 0.827 0.824 20.0 0.859 0.843 0.873 0.879 22.5 0.867 0.850 0.887 0.886 27.5 0.892 0.850 0.896 0.895 32.5 0.887 0.868 0.902 0.902 45.0 0.938 0.905 0.928 0.915 4

Table 2. The percentage deviations between the ROFs obtained using the films (EBT2 and EBT3) and ionization chamber (PP), relative to the MC simulation, for different circular cone diameters. Cone (mm) Deviations (%) EBT2/MC EBT3/MC PP/MC 10.0-20.03-18.86-14.73 15.0 0.62 1.10 0.37 20.0-2.24-4.06-0.65 22.5-2.14-4.06 0.11 27.5-0.34-5.03 0.11 32.5-1.71-3.82-0.05 45.0 2.56-1.05 1.47 Unlike the ionisation chamber, the self-developed Gafchromic films record doses through indirect measurement. Thus, the films were required to be rested for the first 24 hours following irradiation, before they can be read and analysed. Still, systematic error may be introduced during the measurement, as well as the scanning process. This is because, the flatbed scanner was not specifically made for film dosimetry, and thus, hardware issues may be present, which could results in a dose fluctuation. Human error may also be present during the setup of the experiment, the scanning process and analysis of the films using the dosimetric software. The energy dependence of the films may be another contributor to the variations. Nonetheless, for the 6 MV photon beams used in this study, a relatively small difference in the films response of < 10 % were demonstrated, from 60 KeV to MeV range [15]. 4. Conclusion Gafchromic EBT2 and EBT3 films were shown to be capable of measuring the ROFs for small-field photon beams, due to their features, i.e. lack in lateral electronic equilibrium, high in spatial resolution, and near tissue equivalent. Both films are inexpensive and provide good option for smaller radiotherapy centre that do not own the equipment or personnel, to perform a more complex smallfield relative dosimetry. However, the films are limited such that, the read out process needs careful attention, to avoid measurement uncertainties. Therefore, based on the special characteristics of smallfield photon beams, the PinPoint ionisation chamber was suggested due to its accuracy. However, the EBT2 film can be used as an alternative, when high spatial resolution is required. 5. References [1] Rah J E, Shin D O, Jang J S, Kim M C, Yoon S C and Suh T S 2008 Application of a glass rod detector for the output factor measurement in the CyberKnife Appl. Radiat. Isot. 66 1980-85 [2] Khelashvili G, Chu J, Diaz A and Turian J 2012 Dosimetric characteristics of the small diameter BrainLab (TM) cones used for stereotactic radiosurgery J. Appl. Clin. Med. Phys. 13 4-13 [3] Sharma S D, Kumar S, Dagaonkar S S, Bisht G, Dayanand S, Devi R, Deshpande S S, Chaudhary S, Bhatt B C and Kannan S 2007 Dosimetric comparison of linear acceleratorbased stereotactic radiosurgery systems J. Med. Phys. 32 18-23 [4] R Abdullah, N R N Idris, A Zakaria, A L Yusof, N I Mohsin and M Mohamed 2015 Measurement of dosimetric parameters and dose verification in stereotactic radiosurgery Malaysian J. Health Science 13 39-9 5

[5] Butson M J, Yu P K N, Cheung T and Alnawaf H 2010 Energy response of the new EBT2 radiochromic film to x-ray radiation Radiat. Meas. 45 836-9 [6] Sharpe M B, Jaffray D A, Battista J J and Munro P 1995 Extrafocal radiation: A unified approach to the prediction of beam penumbra and output factors for megavoltage x-ray beams Med. Phys. 22 2065-74 [7] Zhu T C, Bjarngard B E and Shackford H 1995 X-Ray Source and the Output Factor Med. Phys. 22 793-8 [8] R Abdullah, N I Mohsin, M Mohamed, N R N Idris, A Zakaria and A L Yusof 2016 Verification of Relative Output Factor measurement for radiosurgery small photon beams Health Environm. J. 7 20-31 [9] Alalawi A I, Jafari S M, Najem M A, Alsaleh W, Clark C H, Nisbet A, Abolaban F, Hugtenburg R P, Hussein M, Alzimami K S, Bradley D A and Spyrou N M 2014 Preliminary investigations of two types of silica-based dosimeter for small-field radiotherapy Radiat.Phys. Chem. 104 139-44 [10] Ralston A, Liu P, Warrener K, McKenzie D and Suchowerska N 2012 Small field diode correction factors derived using an air core fibre optic scintillation dosimeter and EBT2 film Phys. Med. Biol. 57 [11] Fan J, Paskalev K, Wang L, Jin L, Li J, Eldeeb A and Ma C 2009 Determination of output factors for stereotactic radiosurgery beams Med. Phys. 36 5292-300 [12] Andreo P, Huq M S, Westermark M, Song H J, Tilikidis A, DeWerd L and Shortt K 2002 Protocols for the dosimetry of high-energy photon and electron beams: a comparison of the IAEA TRS-398 and previous international Codes of Practice Phys. Med. Biol. 47 3033-53 [13] Aziz M Z A, Yusoff A L, Osman N D, Abdullah R, Rabaie N A and Salikin M S 2015 Monte carlo dose calculation in dental amalgam phantom. J. Med. Phys. 40 150-5 [14] R J Underwood 2013 Small field dose calibrations with Gafchromic film MSc. Thesis Georgia Institute of Technology [15] Muench P J, Meigooni A S, Nath R and Mclaughlin W L 1991 Photon Energy-Dependence of the sensitivity of Radiochromic film and comparison with Silver-Halide film and Lif Tlds used for brachytherapy dosimetry. Med. Phys. 18 769-75 Acknowledgments This study was supported financially by the Short-term Grant (304/PPSK/61313048) of Universiti Sains Malaysia. This work was made possible with the cooperation of the Nuclear Medicine, Radiotherapy, and Oncology Department, School of Medical Sciences, Hospital Universiti Sains Malaysia, and School of Health Sciences, Universiti Sains Malaysia (USM). 6