Infinity MCable -Microstream CO 2

Similar documents
Infinity MCable -Masimo SET

A decision with a future DRÄGER EVITA INFINITY V500

Tropic plus ultrasonic nebulizer Consumables and Accessories

Dräger Alcotest 3820 Alcohol Screening Device

Dräger DrugCheck 3000 Drug Testing Device

Dräger Alcotest 6820 Alcohol Screening Device

Dräger Alcotest 5510 Alcohol Screening Device

Dräger Alcotest 5820 Alcohol Screening Device

Dräger Alcotest 6810 Alcohol Screening Device

Volume Guarantee Initiation and ongoing clinical management of an infant supported by Volume Guarantee A Case Study

Infinity Kappa Patient Monitor

MT Custom Weaning Protocol for your Ventilator Patients SMARTCARE /PS

D D Non-Invasive Ventilation (NIV) with the Oxylog VE300 and Oxylog 3000 plus

MT Custom Weaning Protocol for your Ventilator Patients SMARTCARE /PS

Electrical Impedance Tomography

Dräger Alcotest 5000 Alcohol Screening Device

Proportional Pressure Support (PPS) Clinicians successfully match patient s respiratory demands and facilitate weaning by using PPS

D Non-Invasive Ventilation (NIV) with the Oxylog 2000 plus and Oxylog 3000 plus

Dräger Mobile Printer

Dräger Alcotest 3820 Alcohol Screening Device

Dräger Alcotest 6820 Alcohol Screening Device

Dräger SSK 5000 Drug Testing Device

X Series Extensive Capabilities

Dräger Alcotest 5510 Alcohol Screening Device

Dräger Alcotest 3820 Alcohol Screening Device

Defibrillators TEC-8300K series. It s all seamless

Dräger Alcotest 3820 Alcohol Screening Device

Dräger Alcotest Handheld Product Suite

Infinity. Kappa XLT Patient Monitor. Because you care

Dräger Alcotest 8610

Natural performance. Introducing the BiPAP A30 - because ease of use and therapy efficacy are key to patient well-being

Capnography for Pediatric Procedural Sedation Learning Module Last revised: February 18, 2014

Cardiocap/5. GE Healthcare. The compact, all-in-one, critical care monitor. Features. Available options

Dräger Alcotest 9510 Evidential Alcohol Measuring Device

TECHNOCARE MEDISYSTEMS

Capnography: The Most Vital Sign

Carina. The compact wonder. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Pain Management Portfolio FAQs

3/30/12. Luke J. Gasowski BS, BSRT, NREMT-P, FP-C, CCP-C, RRT-NPS

June 2011 Bill Streett-Training Section Chief

NomoLine No-moisture sampling lines for intubated and non-intubated patients in low- and high-humidity applications

Dräger Alcotest Hard protective case Robust and weatherproof. All case components power on when the case is opened.

INTUBATION/RSI. PURPOSE: A. To facilitate secure, definitive control of the airway by endotracheal intubation in an expeditious and safe manner

Effective Treatment for Obstructive Sleep Apnoea

Capnography (ILS/ALS)

Assessing Global Patient Status with the Halo Index

Health Tech Symposium Fall, Dan Sommers P.E. EMT-P

CAPNOGRAPHY. 1.1 To set forth the policy and procedure for performing continuous end-tidal waveform capnography.

ETCO2 MONITORING NON-INTUBATED PATIENTS

Transcutaneous Monitoring and Case Studies

Julie Zimmerman, MSN, RN, CCRN Clinical Nurse Specialist

MANUAL MEDICAL DIRECTOR RESPIRATORY BOB MILLER, BS, RRT, RCP RESPIRATORY SERVICES DIRECTOR APPROVED BY

Global Oilfield Solutions. Demulsifiers for the Oil Industry: Basorol

Automated Blood Pressure Monitor

Power to see the big picture

Effective Treatment for Obstructive Sleep Apnoea

Goldman Sachs JBWere Australasian Investment Forum New York - 7 March 2006

Nihon Kohden America. Capnography Monitoring with the CapONE CO2 Sensor For use with the BSM 2300/4100/5100 and the BSM 6000 Series Bedside Monitors

Capnography Connections Guide

Association for Radiologic & Imaging Nursing

2 hospital system, tertiary care, community, referral centers

A Business & Clinical Case for Continuous Surveillance

My CoughAssist. A patient guide to CoughAssist E70

NomoLine No-moisture sampling lines for intubated and non-intubated patients in low- and high-humidity applications

Filter/HMEs: Supporting daily clinical routine SAFESTAR CARESTAR HUMIDSTAR TWINSTAR

experiences that matter

Don t let your patients turn blue! Isn t it about time you used etco 2?

VITAL SIGNS MONITORING. RVS-100/200 ri-vital. Vital Signs Patient Monitors

3880 PORTABLE MRI MONITORING SYSTEM

Identification of patients at risk for Opioid-Induced Respiratory Depression

Appendix D An unresponsive patient with shallow, gasping breaths at a rate of six per minute requires:

Emergency Care Clinical Data Transmission Networks

HOSPITAL PROCEDURE Collaborative Practice Committee

Interfacility Protocol Protocol Title:

ACCESSORIES AND DISPOSABLES

All motion is not created equal.

Appendix E Choose the sign or symptom that best indicates severe respiratory distress.

Capnography 101. James A Temple BA, NRP, CCP

Defibrillators TEC-8300K series. Improving quality of resuscitation

OG TAL ODUCT CA PR e e HEALTH

1 Pediatric Advanced Life Support Science Update What s New for 2010? 3 CPR. 4 4 Steps of BLS Survey 5 CPR 6 CPR.

FY06 Full Year Update & Overview

Respiratory Rate. Disclosure: Research grants and honoraria from Masimo Corp

GE Healthcare. Ohmeda TruSat For wherever your patients take you

End Tidal CO2 Not All Its Cracked Up To Be The Limitations of PETCO2 In Sedation Analgesia

By Mark Bachand, RRT-NPS, RPFT. I have no actual or potential conflict of interest in relation to this presentation.

MasterScope Body. Powered by SentrySuite

CYBERKNIFE M6 SERIES: Unmatched Precision and Patient Comfort

Conflict of Interest Disclosure

Capnography Could Make You a Rock Star!

IFT1 Interfacility Transfer of STEMI Patients. IFT2 Interfacility Transfer of Intubated Patients. IFT3 Interfacility Transfer of Stroke Patients

Safe Use of Opioids in Hospitals: Addressing The Joint Commission Sentinel Event Alert

Check a Pulse! When to Question SpO 2, NIBP & EtCO 2 Readings

ASPIRUS WAUSAU HOSPITAL, INC. Passion for excellence. Compassion for people. SUBJECT: END TIDAL CARBON DIOXIDE MONITORING (CAPNOGRAPHY)

Stellar 100 Stellar 150

Compressor Nebulizer. Model UN-014

microprocessor controlled eddy current brake Load / accuracy Watt, speed independent / according to DIN VDE

EMS System for Metropolitan Oklahoma City and Tulsa 2017 Medical Control Board Treatment Protocols

Capnography. Capnography. Oxygenation. Pulmonary Physiology 4/15/2018. non invasive monitor for ventilation. Edward C. Adlesic, DMD.

Volumetric Infusion Pumps INFUSIONMANAGEMENT

Transcription:

Infinity MCable -Microstream CO 2 With Infinity MCable -Microstream CO 2, measuring the presence of carbon dioxide helps you detect changes in your patient s ventilatory status to pre-empt possible respiratory depression. You ll see continuous waveforms and readings for end-tidal CO 2 concentration, inspiratory CO 2 concentration and respiratory rate on the patient s Infinity M540 monitor. D-2422-2016

02 Infinity MCable -Microstream CO2 Benefits Provides continuous surveillance Capnography provides valuable information about a patient s evolving respiratory status. The early detection of respiratory compromise can lead to a more successful clinical intervention and, potentially, a positive patient outcome. Complements pulse oximetry Combining capnography, pulse oximetry and heart rate measurements on the Infinity M540 monitor gives you a complete picture of a patient s respiratory function in a single view. Continuous monitoring of respiratory status has been shown to reduce rescue events and ICU transfers.1 Serves a wide range of patients Infinity Microstream CO 2 MCable is indicated for intubated and non-intubated patients with a wide selection of sampling lines in neonate, pediatric and adult sizes. Its low flow 50 ml/minute sample rate is effective for all patient types. Reduces distractions The Microstream technology of the Infinity MCable-Microstream CO 2 uses algorithms proven to generate fewer non-essential alarms, potentially improving clinical efficiency and patient safety.2,3 Works with your Infinity Acute Care System The plug-and-play Infinity MCable-Microstream CO 2 /Infinity M540 patient monitoring combination is a costeffective solution, compared with purchasing and maintaining a standalone CO 2 monitor for every patient bed. 1 Taenzer AH, Pyke JB, McGrath SP, Blike GT. Impact of pulse oximetry surveillance on rescue events and intensive care unit transfers: a before-and-after concurrence study. Anesthesiology. 2010;112(2):282-287. 2 Hockman S, Glembot T, Niebel K. Comparison of capnography derived respiratory rate alarm frequency using the SARA algorithm versus an established nonadaptive respiratory rate alarm management algorithm in bariatric surgical patients. Resp Care (Open Forum Abstracts). 2009;12. 3 ECRI Institute. The Hazards of Alarm Overload: Keeping Excessive Physiologic Monitoring Alarms from Impeding Care. ECRI Guidance Article, March 2007.

Infinity MCable -Microstream CO2 03 Accessories Sampling lines Collect and filter breathing samples of neonatal, pediatric and adult patients which are subsequently measured by the MCable-Microstream CO 2. The accessories feature single-patient-use lines for intubated and non-intubated procedures. D-2420-2016 MT-3012-2004 MCable-Microstream CO 2 holder Secures the MCable-Microstream CO 2 and provides a mechanism for mounting the device. Universal pole mount MCable-Microstream CO 2 can be mounted on an IV pole for use during transport or at the bedside. D-2418-2016 D-2423-2016 MCable-Microstream CO 2 pole mount adapter Adapts the MCable-Microstream CO 2 holder to allow mounting of the MCable to an IV pole or bedrail via the universal clamp.

04 Infinity MCable -Microstream CO2 Accessories MCable-Microstream CO 2 extension cable (0.9 m) Lengthens the MCable-Microstream CO 2 connecting cable to the Infinity M540 monitor. D-2427-2016 D-2417-2016 SpO 2 pod mount Allows the MCable-Microstream CO 2 to be mounted to the back of the Infinity M540 monitor by sliding and securing the MCable-Microstream holder onto the SpO 2 pod mount. Related Products Infinity M540 D-19701-2009 Streamline workflows with a monitor that goes from bedside to transport in the push of a button. Leave cables and modules attached to your patient and continue monitoring parameters and alarms in real time, while recording data during travel. Use the Infinity M540 as a standalone monitor, or integrate it with hospital IT to access clinical information systems and data analysis applications.

Infinity MCable -Microstream CO2 05 Related Products Infinity Acute Care System Transform your clinical workflow with Infinity Acute Care System. Its multiparameter monitor integrates with its networked medical-grade workstation, giving you real-time vital signs, access to clinical hospital systems and data management applications for a comprehensive range of patient information and powerful analysis tools at the point-of-care. D-1195-2009 D-19739-2009 Infinity Gateway Suite Get the most out of your clinical information systems. Integrate data from Dräger monitoring and therapy devices with lab results, entries in electronic medical records and clinical information systems across hospital departments. Infinity Gateway applications, interfaces and developer tools enable you to exchange information for a more comprehensive view of your patients.

06 Infinity MCable -Microstream CO2 Technical Data Microstream carbon dioxide concentrations (CO2) CO2 units etco2, inco2 range CO2 waveform resolution etco2, inco2 resolution mmhg or kpa or vol% (as relevant to Microstream capnography) 0 99 mmhg (as relevant to the Microstream capnography) 0.1 mmhg 1 mmhg CO2 partial pressure accuracy 0 to 38 mmhg ± 2 mmhg 1,2,3 Accuracy in presence of interfering gases as required by ISO 80601-2-55 Waveform sampling Respiratory rate range Respiratory rate accuracy Flow rate Leakage rate System Response Rise time Delay time Warm-up period Compression 1 Applies for respiratory rates up to 80 breaths per minute. 39 to 99 mmhg ± [5% of expected reading + 0.08 x (expected reading in mmhg - 39 mmhg)] 1,2,3 The accuracy in presence of interfering gases is within 4% of the accuracy values above; therefore: 0 to 38 mmhg: ± (2 mmhg + 4% of expected reading in mmhg) 39 99 mmhg: ± [9% of expected reading in mmhg + 0.08 x (expected reading in mmhg - 39 mmhg)] 0 to 38 mmhg ± (2 mmhg + 4% of expected reading in mmhg) in the presence of up to 80% helium with up to 15% oxygen 39 99 mmhg: ± [9% of expected reading in mmhg + 0.08 x (expected reading in mmhg - 39 mmhg) in the presence of up to 80% helium with up to 15% oxygen 20 samples/second 0 to 150 breaths per minute 0 to 70 breaths per minute ± 1 breaths per minute 71 to 120 breaths per minute ± 2 breaths per minute 121 to 150 breaths per minute ± 3 breaths per minute 50 ml per minute (tolerance -7.5, +15), flow measured by volume Less than 40 mbar per minute when a 30% vacuum is invoked on the flow system. <190 ms. <2.7 sec. After the system warm up and during steady state Microstream MCable use: the maximum delay time between patient breath and its report on the CO2 waveform is 2.9 sec. Includes power-up time (10 seconds maximum) and initialization time (180 seconds). Total warm-up time 1 minute and 30 seconds maximum. BTPS is the standard correction used by Microstream capnography during all measurement procedures for body, temperature, pressure, and saturation. 2 For respiratory rates above 80 breaths per minute, accuracy is 4 mmhg or ± 12% of reading, which-ever is greater, for etco2 values exceeding 18 mmhg. 3 For respiratory rates above 60 breaths/minute, the Microstream FIlterLine H Set for Infant/Neonatal is required. Physical specifications MCable dimensions (height x width x depth) MCable weight MCable Holder dimensions (height x width x depth) MCable Holder weight 92 mm (3.6 in) x 70 mm (2.7 in) x 49 mm (1.9 in) 240 grams (0.52 pounds) 106 mm (4.2 in) x 87 mm (3.4 in) x 70 (2.8 in) 100 grams (3.52 ounces)

Infinity MCable -Microstream CO2 07 Technical Data Electrical specifications Power source Mode of Operation Powered directly from the M540 Continuous Risk management Protection against electrical shock Protection against liquid ingress Defibrillator protection Type BF IPX2 (protected against vertically falling water drops) per IEC 60529 Yes Ordering Information MCable-Microstream CO2 MCable-Microstream CO2 kit MCable-Microstream CO2 MCable-Microstream CO2 holder MCable-Microstream CO2 pole mount adapter Order No. MS33160 MS32641 MS32642 MS32774 Universal pole mount 74 85 621 MCable-Microstream CO2 extension cable 68 72 159 Test gas etco2 kit Microstream CO2 Accessories for Intubated Patients Adult/Pediatric MS16684 CO2 Microstream airway adapter, adult/pedi 78 69 535 CO2 Microstream airway adapter, ICU, adult/pedi 78 69 543 Neonate/Pediatric etco2 Microstream airway adapter, neo/pedi 78 69 550 Microstream CO2 Accessories for Non-intubated Patients Adult CO2 Microstream nasal cannula, adult 78 69 477 CO2 Microstream nasal cannula, ICU, adult 78 69 592 CO2 Microstream nasal cannula plus 02, adult 78 69 493 CO2 Microstream nasal/mouth cannula, adult/intermediate CO2 Microstream nasal/mouth cannula plus 02, adult/ intermediate Pediatric MS26187 MS26188 CO2 Microstream nasal cannula, pedi 78 69 469 CO2 Microstream nasal cannula plus 02, pedi 78 69 485 CO2 Microstream nasal/mouth cannula plus 02, pedi 78 69 584 CO2 Microstream nasal cannula, pedi 78 69 501 Neonate/Pediatric CO2 Microstream nasal cannula ICU, neo/pedi 78 69 618 Microstream is a trademark of Medtronic, Inc. The Dräger name and logo, Infinity and MCable are registered trademarks of Dräger.

08 Infinity MCable -Microstream CO2 Notes 91 01 152 16.04-1 HQ PP Subject to modifications 2016 Drägerwerk AG & Co. KGaA CORPORATE HEADQUARTERS Drägerwerk AG & Co. KGaA Moislinger Allee 53 55 23558 Lübeck, Germany www.draeger.com Manufacturer: Draeger Medical Systems, Inc. 3135 Quarry Road Telford, PA 18969-1042, USA REGION DACH Drägerwerk AG & Co. KGaA Moislinger Allee 53 55 23558 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 2080 info@draeger.com REGION EUROPE Drägerwerk AG & Co. KGaA Moislinger Allee 53 55 23558 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 2080 info@draeger.com REGION MIDDLE EAST, AFRICA Drägerwerk AG & Co. KGaA Branch Office P.O. Box 505108 Dubai, United Arab Emirates Tel +971 4 4294 600 Fax +971 4 4294 699 contactuae@draeger.com REGION ASIA / PACIFIC Draeger Medical South East Asia Pte Ltd. 25 International Business Park #04-27/29 German Centre Singapore 609916, Singapore Tel +65 6572 4388 Fax +65 6572 4399 asia.pacific@draeger.com REGION NORTH AMERICA Draeger, Inc. 3135 Quarry Road Telford, PA 18969-1042, USA Tel +1 800 4DRAGER (+1 800 437 2437) Fax +1 215 723 5935 info.usa@draeger.com REGION CENTRAL AND SOUTH AMERICA Dräger Panama Comercial S. de R.L. Complejo Business Park, V tower, 10th floor Panama City Tel +507 377 9100 Fax +507 377 9130 contactcsa@draeger.com Locate your Regional Sales Representative at: www.draeger.com/contact