Background: Bedside ultrasound is emerging as a useful tool in the assessment of

Similar documents
Correlation between Central Venous Pressure and Inferior Vena Cava Sonographic Diameter; Determining the Best Anatomic Location

Point-of-Care Ultrasound Closer look at the Inferior Vena Cavae &

Derivation of a pediatric growth curve for inferior vena caval diameter in healthy pediatric patients: brief report of initial curve development

Dehydration from gastroenteritis remains a common

Identification of congestive heart failure via respiratory variation of inferior vena cava diameter,

Inferior vena cava diameters and collapsibility index reveal early volume depletion in a blood donor model

Research Article Caval Aorta Index and Central Venous Pressure Correlation in Assessing Fluid Status! Ultrasound Bridging the Gap

Abstract. ª 2011 by the Society for Academic Emergency Medicine 912 PII ISSN doi: /j

The Effect of Weight-based Volume Loading on the Inferior Vena Cava in Fasting Subjects: A Prospective Randomized Double-blinded Trial

Perioperative Ultrasonography Ehab Farag, MD, FRCA Hesham Elsharkawy David G. Anthony, M.D.

ORIGINAL ARTICLE. Role of Ultrasound in Evaluation of Undifferentiated Shock in ICU Settings

The role of bedside ultrasound in the diagnosis of pericardial effusion and cardiac tamponade

Ultrasound in Emergency Medicine

Use of Ultrasound Measurement of the Inferior Vena Cava Diameter as an Objective Tool in the Assessment of Children with Clinical Dehydration

Resident & Student Association. Activities

Original Research Article

Doppler Basic & Hemodynamic Calculations

Estimation of Right Atrial Pressure from the Inspiratory Collapse of the Inferior Vena cava in Pediatric Patients

Guide to Small Animal Vascular Imaging using the Vevo 770 Micro-Ultrasound System

Sonographic measurement of the inferior vena cava as a marker of blood loss

Evolution of Clinical Anatomy with Ultrasonography Past Present and Future

Min Hur, Eun-Hee Kim, In-Kyung Song, Ji-Hyun Lee, Hee-Soo Kim, and Jin Tae Kim INTRODUCTION. Clinical Research

Prof. Dr. Iman Riad Mohamed Abdel Aal

Background & Indications Probe Selection

Ultrasonography of jugular vein as a marker of hypovolemia in healthy volunteers

Guidelines, Policies and Statements D20 Statement on Peripheral Venous Ultrasound

Objectives. Hepatobiliary Ultrasound: Anatomy, Technique, Pathology. RUQ: Normal Anatomy. Emergency Ultrasound: Gallbladder Location

Focused Assessment Sonography of Trauma (FAST) Scanning Protocol

PART II ECHOCARDIOGRAPHY LABORATORY OPERATIONS ADULT TRANSTHORACIC ECHOCARDIOGRAPHY TESTING

Point-of-Care Ultrasound Guide for Landmarks, Recording, and Report Content. TJUH/MHD EM Ultrasound Division 2012

LOWER EXTREMITY VENOUS COMPRESSION ULTRASOUND. CPT Stacey Good, DO Emergency Medicine Ultrasound Fellow Madigan Army Medical Center

Abdominal Ultrasonography

Certificate in Clinician Performed Ultrasound (CCPU) Syllabus. Rapid Cardiac Echo (RCE)

Upper Extremity Venous Duplex Evaluation

Intro Case. Outline What We ll Cover. What we won t cover. Cardiac Ultrasound and The RUSH Exam: Bedside Ultrasound in Resuscitation and Shock

The role of ultrasound duplex in endovenous procedures

My Patient Has Abdominal Pain PoCUS of the Biliary Tract and the Urinary Tract

Bedside Ultrasound. US Guided Fluid Resuscitation. Michiel J. van Veelen, Emergency Physician, DTM&H

Hemodynamic Assessment. Assessment of Systolic Function Doppler Hemodynamics

Duplex ultrasound is first-line imaging for all

Certificate in Clinician Performed Ultrasound (CCPU) Syllabus. Basic Echocardiography in Life Support

Biliary Ultrasonography Kathleen O Brien MD MPH RDMS Kaiser Permanente South Sacramento

Ultrasonography for Novices

Background & Indications Probe Selection

Pericardial Diseases. Smonporn Boonyaratavej, MD. Division of Cardiology, Department of Medicine Chulalongkorn University

CARDIOLOGY AND CARDIOVASCULAR ANESTHESIA

Adult Echocardiography Examination Content Outline

Adel Hasanin Ahmed 1

Echocardiographic Cardiovascular Risk Stratification: Beyond Ejection Fraction

Department of General Medicine, Kilpauk Medical College and Hospital, Chennai, Tamil Nadu, India * Corresponding author

Research Article Comparison of Colour Duplex Ultrasound with Computed Tomography to Measure the Maximum Abdominal Aortic Aneurysmal Diameter

Bedside Ultrasound for DVT. Linear Probe. Leg Veins

A Practical Approach to Ultrasound Assessment of Respiratory Distress

Certificate in Clinician Performed Ultrasound (CCPU) Syllabus

University of Cape Town

Disclosures. Cardiac Ultrasound. Introductory Case. 80 y/o male Syncope at home Emesis x 3 in ambulance Looks sick. No pain.

The faculty will include physicians with international reputations as outstanding ultrasound educators.

Pediatric Lung Ultrasound (PLUS) In Diagnosis of Community Acquired Pneumonia (CAP)

Abdominal Ultrasound. Diane Hallinen, MD. Bloodroot

Effect of Bedside Ultrasonography on the Certainty of Physician Clinical Decisionmaking for Septic Patients in the Emergency Department

Lower Extremity Venous Insufficiency Evaluation

Shock, Monitoring Invasive Vs. Non Invasive

Bedside Ultrasound for Detection of Deep Vein Thrombosis: the Two-Point Compression Method

Point of Care Ultrasound in the ICU

Hepatobiliary Ultrasound Rimon Bengiamin, MD, RDMS Assistant Clinical Professor Director of Emergency Ultrasound UCSF Fresno. Objectives. Why?

Echocardiography Volume assessment. Justin Mandeville 2014

Abdomen and Retroperitoneum Ultrasound Protocols

Caroline Polley, BSN, RN, VA-BC Clinical Specialist BD

Assessment of clinical dehydration using point of care ultrasound for pediatric patients in rural Panama

Estimation of Right Atrial Pressure on Inferior Vena Cava Ultrasound in Asian Patients

The Flat Cava Sign Revisited: What is its Significance in Patients Without Trauma?

Bedside RUQ Ultrasound. Replace Formal ULS? Why Bedside ULS RUQ? RUQ Ultrasound. Bedside ULS is Limited, Goal-Directed

Basic of Ultrasound Physics E FAST & Renal Examination. Dr Muhammad Umer Ihsan MBBS,MD, DCH CCPU,DDU1,FACEM

Optimal Filter Placement

Relax and Learn At the Farm 2012

Tissue Doppler Imaging in Congenital Heart Disease

CATCH A WAVE.. INTRODUCTION NONINVASIVE HEMODYNAMIC MONITORING 4/12/2018

Peripheral intravenous (IV) access is often a vital

Revealing new insights. irotate electronic rotation and xplane adjustable biplane imaging. Ultrasound cardiology. irotate and xplane

Point of Care Ultrasound (PoCUS)

Principles of Ultrasound. Cara C. Prideaux, M.D. University of Utah PM&R Sports Medicine Fellow March 14, 2012

Distinguishing Right From Left: A Standardized Technique for Fetal Echocardiography

Accuracy of Emergency Physician Assessment of Left Ventricular Ejection Fraction and Central Venous Pressure Using Echocardiography

This appendix was part of the submitted manuscript and has been peer reviewed. It is posted as supplied by the authors.

HOW TO SET UP THE ECHO LAB?

Mary Lou Garey MSN EMT-P MedFlight of Ohio

Non Contrast MRA. Mayil Krishnam. Director, Cardiovascular and Thoracic Imaging University of California, Irvine

Right Heart Hemodynamics: Echo-Cath Discrepancies

ECO Course. General Information Guide. Echocardiography & Clinical Ultrasound Online COURSE OBJECTIVES WHO WE ARE

Fig MHz cm/s. Table 1 Fig. 2. Fig. 3, 4. Fig. 5

Diagnosis in your pocket:

AAENP US WORKSHOP 2/25/17

Abdominal ultrasound:

Carotid Abnormalities Coils, Kinks and Tortuosity David Lorelli M.D., RVT, FACS Michigan Vascular Association Conference Saturday, October 20, 2012

The caval index: an adequate non-invasive ultrasound parameter to predict fluid responsiveness in the emergency department?

Rotation: Echocardiography: Transthoracic Echocardiography (TTE)

Cardiac ultrasound protocols

Emergency Ultrasound. Case ECG. Potential diagnoses. An 80-year-old man in shock. ED patient with non traumatic undifferentiated hypotension

Diagnosis of Intussusception by Physician Novice Sonographers in the Emergency Department

ULTRASOUND OF THE FETAL HEART

Transcription:

Abstract: Background: Bedside ultrasound is emerging as a useful tool in the assessment of intravascular volume status by examining measurements of the inferior vena cava (IVC). Many previous studies do not fully describe their scanning protocol. Objectives: The objective of our study is to evaluate which of three commonly reported IVC scanning methods demonstrates the best inter-rater reliability. Methods: Three physicians visualized the IVC in the three planes and utilized M-mode to measure the maximal and minimal diameter during quiet respiration. Pair-wise correlation coefficients were determined using Pearson Product Moment Correlation. Results: The most reliable pair of measurements (inspiratory and expiratory) was using the anterior mid-axillary line longitudinal view with a Kappa value for both at 0.692. Conclusion: Imaging with the anterior mid-axillary longitudinal approach using the liver as an acoustic window provides the best inter-rater reliability in measurements of the IVC. Likewise, our findings demonstrate that IVC measurements differ based on anatomic location Keywords: Intravascular volume status, inferior vena cava, bedside ultrasound

Introduction Central venous pressure (CVP) monitoring is advocated as the most accurate measure to assess for hydration and volume status in the treatment of cardiogenic and noncardiogenic shock. However, CVP monitoring requires the insertion of an invasive catheter with risks including infection, hemorrhage, pneumothorax, dysrhythmias, and venous thrombosis. Furthermore, placement of the catheter is expensive and time and resource consuming in a busy emergency department. Bedside ultrasound is emerging as a useful tool in the assessment of intravascular volume status. Bedside ultrasound measurements of the inferior vena cava (IVC), including IVC diameter, the degree of collapse of the IVC on inspiration versus expiration and the IVC/aorta diameter index, are all proposed non-invasive alternatives to CVP monitoring in assessing hydration status. 1-5 However, different studies have proposed different approaches to imaging the IVC. Lyon et. al. and Kosiak et. al. and others used a subxyphoid approach to view the IVC along the longitudinal axis, using the liver as a sonographic window. 1,5-7 Pershad et. al. and Blehar et al measured the IVC in the subxyphoid transverse axis just caudal to the hepatic vein confluence. 8,9 To our knowledge, no previous study has determined the inter-observer variability in measurements using different approaches to IVC imaging and measurements. The objective of our study is to evaluate which of the three most commonly reported IVC scanning methods (Figure 1) demonstrates the best inter-rater reliability: 1. subxyphoid longitudinal plane (SXL) (Figure 2) 2. subxyphoid transverse plane (SXT) (Figure 3) and

3. anterior mid-axillary line longitudinal (AML) (Figure 4) using the liver as a sonographic window.

Methods We selected healthy volunteers for a prospective observational study. The protocol was approved by the institutional review board at our institution. The bedside ultrasound examinations were performed by 3 physicians, one attending physician who had completed an emergency ultrasound fellowship and two fellows in emergency ultrasound. The three physicians had each completed at least 175 technically adequate ultrasound scans prior to this study. Each physician spent approximately one hour reviewing the principles and techniques of IVC scanning prior to study initiation. These included visualizing the IVC in the three planes and utilizing M-mode to measure the maximal and minimal diameter. Wallace et.al. suggest that M-mode measurements may be inaccurate because the movement of the diaphragm during respiration can result in caudal displacement of the IVC. 10 With a stationary probe, this physiologic variation is also possible when visualizing the structure in a B-mode cine loop. Therefore, we chose to perform IVC evaluation in M-mode for the ease of interpretation of location of maximal and minimal diameters as well as their measurements in one screen image. Our sample consisted of medical students rotating through the department and family members who were accompanying patients in the emergency department. No individual was there to seek medical care in the emergency department. Inclusion criteria included any patient > 18 years of age willing to participate in the study. Individuals < 18 years of age or refused to participate were excluded from the study. No attempt was made to control for past medical history, medication use or hydration status.

Volunteers were placed in the supine position with the head at 0 degrees. A Sonosite Titan portable ultrasound machine was used with a C15 (2-4 MHz) broadband transducer on the abdominal setting. Subjects received no instructions on how to breath and all measurements were taken during quiet respiration. Identification of the IVC by anatomic landmarks was confirmed with color Doppler imaging. Three IVC views were obtained 1. subxiphoid in a longitudinal plane (SXL), 2. subxiphoid in a transverse plane (SXT) and 3. anterior mid-axillary line in a longitudinal plane (AML), using the liver as a sonographic window. For each view, the IVC was observed during three respiratory cycles. M-mode assessment was performed 2 centimeters distal to the junction of the IVC and the right atrium, at a point where the two walls were parallel (Figure 5). The probe was held perpendicular to the vessel during the measurements. A cine loop was recorded during three respiratory cycles. Using frame-by-frame review, calipers were used to measure minimal and maximal diameters in millimeters during inspiration and expiration. The internal diameter of the IVC was used for all measurements. No attempt was made to evaluate if the measurements were taken during systole or diastole. All three sonographers performed measurements separately and in succession, without the volunteer shifting position between scans. All measurements were collected and organized into a database. For each volunteer, the three measurements for IVC diameter during inspiration and the three measurements for

IVC diameter during expiration were averaged for each view. The data was analyzed using pairwise correlation. The data was continuous so the Pearson Product Moment Correlation was used. This allowed the most reproducible measurements between operators for each of the views.

Results 14 adult volunteers were enrolled in the study. Measurements of the IVC in each of the three anatomic locations were obtained in all patients. 141 paired inspiratory and expiratory measurements were recorded for SXL view, 138 for the SXT view, and 138 for the AML view. For each volunteer, we averaged the three measurements for each view for IVC diameter during inspiration and the three measurements for IVC diameter during expiration. We present the measurements in millimeters using means and standard deviations (parenthesis) in Table 1. The average IVC diameter during expiration was 19.5 mm for the SXL view, 18.7 for the SXT view, and 19.1 for the AML view. Inspiratory IVC measurements were 13.3, 12.7, and 14.1 respectively. Respiratory variation was best observed through the SXL approach with an average change in diameter of 6.27 mm compared to 6.03 mm and 4.92 mm for the SXT and AML approaches respectively. Operators 1 and 2 each recorded individually 51 paired inspiratory and expiratory measurements in the SXL view, 51 in the SXT view, and 51 in the AML view. Operator 3 recorded 39 paired measurements in the SXL view, 36 in the SXT view, and 36 in the AML view. Average measurements of the IVC varied by operator and are summarized in Table 2. There was a statistically significant difference in the respiratory change obtained using the SXT approach (P<0.05). There was no significant difference in the measurements obtained by the other approaches. Because only operators 1 and 2 performed measurements on all of our volunteers (operator 3 scanned 12 volunteers), Operator 3 was excluded from inter-observer

agreement analysis because data for all volunteers was not recorded. We analyzed the pairwise correlation between operators using the Pearson Product Moment Correlation, assuming the data to be parametric (Table 3). We used an alpha of 0.05 for statistical significance. The highest inter-rater agreement for IVC diameter measurements was the inspiratory view using the SXT approach. However, the most reliable pair of measurements (inspiratory and expiratory) was using the AML view with identical pairwise correlations for both at 0.692.

Discussion Multiple previous studies have demonstrated that ultrasonographic imaging of the IVC is a useful non-invasive alternative to CVP monitoring in assessing patients hydration status in the emergency department. However, different studies have proposed imaging from different anatomic locations and there is no agreement as to which is the most reliable method for obtaining IVC measurements. We know based on results from previous studies that measurements of the IVC will vary by anatomic location. In one study it was demonstrated that the percentage collapse of the IVC will vary between anatomic locations. 9 However, to our knowledge there is no previous study that describes the interobserver variability in measurements using different approaches to IVC imaging. Our study is the first to investigate the interobserver variability in measurements of the IVC using three different approaches: 1. subxyphoid longitudinal plane (SLP) 2. subxyphoid transverse plane (STP) and 3. anterior mid-axillary line longitudinal (AML) using the liver as a sonographic window. The results of this study suggest that the AML approach provides the best inter-rater reliability, however, the results are very close and all 3 approaches provide a good inter-rater reliability in obtaining IVC measurements. Our study also reiterates that IVC measurements will vary by anatomic location. Therefore when different observers will be imaging the IVC, measurements should always be obtained from a consistent anatomic location, especially when investigating correlation to CVP. We caution that future studies should clearly describe the scanning

approach used and whether there was consistency throughout the investigation in the anatomic location chosen for imaging. Limitations There are several limitations to this study. First, the study was performed in adult presumably healthy volunteers. However, we collected neither demographic data nor parameters that would indicate the individual s intravascular volume status. This prospective observational convenience sample of people was small in size (14) and more people would need to be enrolled to power these trends in our findings and draw strong conclusions. In addition, only operators 1 and 2 scanned all the volunteers and therefore operator 3 had to be excluded from inter-observer agreement analysis.

Conclusion Imaging through the anterior mid-axillary longitudinal approach using the liver as an acoustic window provides the best inter-rater reliability in measurements of the inferior vena cava. Likewise, our findings demonstrate that IVC measurements differ based on anatomic location making it difficult to draw comparisons between previous research studies. It is our hope that this brief report will encourage further researchers to standardize the anatomic approach in measuring IVC diameter as a non-invasive marker of hemodynamic status.

References 1 Lyon, M, Blaivas, M and Brannam, L. Sonographic measurement of the inferior vena cava as a marker of blood loss. The American Journal of Emergency Medicine 2005; 23:45-50. 2 Chen, L, Kim, Y, Santucci, KA. Use of Ultrasound Measurement of the Inferior Vena Cava Diameter as an Objective Tool in the Assessment of Children with Clinical Dehydration. Academic Emergency Medicine 2007 14: 841-845 3 Simonson, JS and Schiller, NB. Sonospirometry: a new method for noninvasive estimation of mean right atrial pressure based on two-dimensional echocardiographic measurements of the inferior vena cava during measured inspiration. Journal of the American College of Cardiology 1988; 11:557-564. 4 Chen L, Hsiao A, Langhan M, Riera A, Santucci KA. Use of Bedside Ultrasound to Assess Degree of Dehydration in Children With Gastroenteritis. Academic Emergency Medicine 2010; 17: 1042-1047. 5 Nagdev AD, Merchang RC, Tirado-Gonzalez A, Sisson CA, Murphy MC. Emergency department Bedside Ultrasonographic Measurement of the Caval Index for Non-invasive Determination of Low Central Venous Pressure. Annals of Emergency Medicine. 2010; 55:290-295.

6 Jones AE, Kline JA. Use of Goal-Directed Therapy for Severe Sepsis and Septic Shock in Academic Emergency Departments. Critical Care Medicine 2005 Vol. 33, No. 8 7 Kosiak, W, Swieton, D, Piskinowicz, M. Sonographic inferior vena cava/aorta diameter index, a new approach to the body fluid status assessment in children and young adults in emergency ultrasound-preliminary study. American Journal of Emergency Medicine 2008: 26(3): 320-325. 8 Pershad, J, Myers, S, Plouman, C et.al. Bedside Limited Echocardiography by the Emergency Physician Is Accurate During Evaluation of the Critically Ill Patient. Pediatrics 2004; 114: 667-671. 9 Blehar, DJ, Dickman, E, Gaspari, R. Identification of Congestive Heart Failure via Respiratory Variation of Inferior Vena Cava Diameter. American Journal of Emergency Medicine 2009; 27: 71-75. 10 Wallace, DJ, Allison, M, Stone, MB. Inferior Vena Cava Percentage Collapse During Respiration Is Affected by the Sampling Location: An Ultrasound Study in Healthy Volunteers. Academic Emergency Medicine 2009; 17(1): 96-99.

Article Summary: 1. Why is this topic important? Assessing intravascular volume status is necessary when caring for the critically ill. Bedside ultrasound of the inferior vena cava offers a non-invasive mean of this assessment. 2. What does this study attempt to show? There are a number of ways to measure the inferior vena cava sonographically. This study examines the inter-rater reliability of three different scanning techniques. 3. What are the key findings? The anterior mid-axillary line longitudinal view had the best inter-rater reliability. 4. How is patient care impacted? Using this non-invasive bedside tool is safer for patients. Standardizing the scanning method of inferior vena cava measurements as a marker of intravascular volume status will make it easier to compare future research studies.