Presentation Product & clinics

Similar documents
NO MORE NEWS AN EVIDENCE BASED APPROACH ON LASERS IN SKIN OF COLOR PATIENTS DR. EDUARDO WEISS, M.D., FAAD

BISON. Accento. 755nm Long Pulsed Alexandrite Laser 1064nm Long Pulsed Nd:YAG Laser FOR EXPORT ONLY

Hands-on: Lasers. NonAblative Rejuvenation

Treatment of Leg Telangiectasia (Spider Veins) with Magma Long Pulse ND - Laser 1064 nm Case Study

Multi-Application Platform. Summary of Peer-reviewed Articles for Various Clinical Indications April 2016

INTENSE PULSED LIGHT VERSUS ADVANCED FLUORESCENT TECHNOLOGY PULSED LIGHT FOR PHOTODAMAGED SKIN: A SPLIT-FACE PILOT COMPARISON

LASERS: CAN THEY TREAT SPIDER VEINS? Steven E. Zimmet, MD

M & T srl. medical & technology

Aesthetic Laser Industry Why the excitement?

Treatment of Postpartum Leg Telangiectasia (Spider Veins) with Magma Long Pulse ND - Laser 1064 nm Case Study

Dual wavelength (1540nm nm) mixed technology for fractional resurfacing in skin rejuvenation Background

Chapter 21: FotoFacial RF Pro Treatment of Specific Clinical Subtypes

Icon specifications. Handpiece compatibility

FEB-2015 ISSUE. Dr. David Pudukadan

Diode and diode pumped frequencies doubled solid state. 940 nm, 532 nm

Light EVO. Taking care of people, our masterpieces. Multiple Wavelengths for the Highest Challenges in Laser Applications.

NONABLATIVE RESURFACING

Superior RF Multi-Treatment Platform

Superior RF Multi-Treatment Platform

High Power CO2 Laser + Micro-needle Fractional RF

LIGHT SERIES MULTIPLE WAVELENGTHS FOR THE HIGHEST CHALLENGES IN LASER APPLICATIONS

In-vivo histopathological study of YouLaser MT interaction with the skin. A laser device emitting combined 1540 and nm wavelengths.

Casnigo, April, the 21 st, Operative Protocols for PRISMA Nd: YAG laser 1440

The starting point to your success. Light LUMENIS.COM/AESTHETIC

Advances in Lasers for Skin of Color

Laser Treatment of Leg Veins

NEW IN-DEMAND AESTHETICS IN ONE PLATFORM TECH BREAKTHROUGH PLUS

Technology You Trust Innovation You Need

Our Approach to Non-Ablative Treatment Of Photoaging

SPECIAL TOPIC. AboutSkin Dermatology & DermSurgery, Greenwood Village, CO b. The Aesthetic Clinique, Destin, FL c

Prospective, Comparative Evaluation of Three Laser Systems Used Individually and in Combination for Axillary Hair Removal

BBLs BroadBand Light. Daryl Mossburg, RN BSN Clinical Specialist Sciton, Inc. All rights reserved.

ProFractional. ProFractional Therapy. Tunable Fractional Solution. Advanced Fractional Aesthetic Laser Surgery

Clinical Efficacy and Statistical Evaluation of INTRAcel Treatment

Mona SC-2 Ultra Pulse Co2 Fractional laser system. Beijing Sanhe Beauty S & T Co.,Ltd

A Clinical, Histological, and Computer-Based Assessment of the Polaris LV, Combination Diode, and Radiofrequency System, for Leg Vein Treatment

Diode Lasers Enable Diverse Therapeutic Applications

CLINICAL EVALUATION REPORT ON THE EFFICACY AND SAFETY OF THE CORE SYSTEM FOR FACIAL ENHANCEMENT TREATMENTS

Low-fluence Q-switched neodymium-doped yttrium aluminum garnet (1064nm) laser for the treatment of facial melasma in local population

combining Fractional RF and Superficial RF

NOVEL MULTI-SOURCE PHASE-CONTROLLED RADIOFREQUENCY TECHNOLOGY FOR NON- ABLATIVE AND MICRO-ABLATIVE TREATMENT OF WRINKLES, LAX SKIN AND ACNE SCARS

GentleFamily. GentleLASE, GentleYAG, GentleMAX & Pro Series. Banubeautylaser.com.au

The Professional Choice

STUDY. A Comparison of 3 Lasers and Liquid Nitrogen in the Treatment of Solar Lentigines

NEOGENEVO ENERGIST NITROGEN PLASMA SYSTEM SKIN RESURFACING SKIN REJUVENATION SKIN TIGHTENING SKIN REGENERATION SEVERE AND FINE WRINKLE REDUCTION

Dual modality body shaping study with RF and IR technologies utilizing SharpLight s FormaxPlus Platform.

Reports on Scientific Meeting

XF Microlens Optic and XD Microlens Compression Optic for Non-Ablative Fractional Skin Treatment with the Palomar Icon System

In Vivo Histological Evaluation of a Novel YSGG Ablative Fractional Device for Cutaneous Remodeling

Therapeutic Efficacy and Safety of Wavelength-Converted 660-nm Q-Switched Ruby-Like Versatile YAG Treatment on Various Skin Pigmentation Disorders

Clinical Study Treatment of Mesh Skin Grafted Scars Using a Plasma Skin Regeneration System

Laser Skin Rejuvenation

Non-Ablative Rejuvenation

Photodamaged skin occurs as a result of its

ACNE IS A COMMON DISORder,

Clinical experiences in Asian skin with new technology of ablative fractional Er:YAG Laser

Efficacy and safety of ablative fractional carbon dioxide laser for acne scars

Non-ablative Acne Scar Reduction with a Short-Pulsed 1064-nm Nd:YAG Laser a Pilot Study

Laser Skin Rejuvenation

Using Normal and High Pulse Coverage With Picosecond Laser Treatment of Wrinkles and Acne Scarring: Long Term Clinical Observations

Just the Facts Ma am

Treatment of aging skin using the SharpLight Omnimax Stacked multiple modality platform

Introduction. Device Description. Dual-Band Spectral Output

Treatment Effects of Combined Radio-Frequency Current and a 900 nm Diode Laser on Leg Blood Vessels

Efficacy and Safety of Picosecond 755-nm Alexandrite Laser With Diffractive Lens Array for Non-Ablative Rejuvenation in Chinese Skin

Randomized Controlled Trial: Comparative Efficacy for the Treatment of Facial Telangiectasias With 532 nm Versus 940 nm Diode Laser

ClearSkin. Er:Glass 1540nm Laser Module. Orly Baror Gal, Eng.BioMedical. Clinical Applications Specialist

Nonablative Skin Tightening: A Review of the Literature

NEOGEN Evo ENE RGI ST NITROGEN PLASMA SYSTEM ARTG SKIN RESURFACING SKIN REGENERATION SOFT BLEPHAROPLASTY MELASMA SKIN TIGHTENING

An In-Depth Examination of Radiofrequency Assisted Liposuction (RFAL)

LightSheer INFINITYTM

Treat Your Patients Better

PHOTO REJUVENATION UTILIZING A KRYPTON LIGHT SOURCE:A CLINICAL AND HISTOLOGICAL STUDY

Daryl Mossburg, BSN RN Clinical Specialist Sciton, Inc.

Nonablative Infrared Skin Tightening in Type IV to V Asian Skin: A Prospective Clinical Study

Available online at Vol. 07, No. 02, pp , February, 2018 RESEARCH ARTICLE

Chapter 19: FotoFacial RF Pro Parameters

Treatment of Refractory Rosacea with a Dual Wavelength Long- Pulsed 755-nm Alexandrite and 1,064-nm Nd:YAG Laser

QuattroLux Photo-dynamic Therapy LED

RightLight TM Technology Enhanced Dye Wavelengths. WHITE PAPER Synchro VasQ

Andrei Metelitsa, MD, FRCPC, FAAD Clinical Associate Professor, Dermatology, U of C Co-Director, Institute for Skin Advancement

M u l t i - A p p l i c a t i o n L a s e r S y s t e m

High Intensity Focused Ultrasound Facial Skin Lifting

L ASER THER APIES. Wrinkle treatment Skin firming Pore reduction Acne Portwine stains UV light

Ruby Laser Hair Removal: Evaluation of Long-Term Efficacy and Side Effects

Ellipse hair removal offers clinically-proven, safe and effective long-term removal of unwanted hair. How does Ellipse Hair Removal Work?

Evaluating facial pores and skin texture after low-energy nonablative fractional 1440-nm laser treatments

Background Head Quarter Promoter Holding Pattern Turnover

Arisa Ortiz, MD Director, Laser and Cosmetic Dermatology Assistant Clinical Professor Department of Dermatology UC San Diego

#1 LASER PLATFORM IN THE WORLD S 2ND LARGEST AESTHETIC MARKET. An Adavium Medical Company

Special editorial section. May 2010 Practical Dermatology 23

Conventional ablative carbon dioxide (CO 2 ) and

UltraPulse Encore. Bridge Therapy Fractional CO 2.

Reduces the appearance of cellulite and improves the appearance of the skin.

Frequently Asked Questions

NEHSNORTH EASTERN HEALTH SPECIALISTS

Perfect skin with cosmetic mole removal

Laser hair reduction uses long-pulse lasers emitting

Focused Ultrasound Body-shaping system Beijing Sanhe Beauty S & T Co.,Ltd

Transcription:

Presentation Product & clinics

Design

What s Long Pulse Nd:YAG? medium YAG (Yuttrium Aluminum Garnet : Y 3 Al 5 O 12 ) + Nd 3+

The Wavelength Penetrates All kind of Hair removal Each laser possesses specific characteristics that enable it to penetrate the skin's surface at a certain depth. Aileen penetrates 6 mm into the skin s surface which facilitates the removal of various types of hair follicles located at different depths.

Correlation with spot size and laser penetration depth A larger spot size enables greater penetration depth which improves absorption of energy to the targeted hair follicle. Aileen offers up to 15mm spot size Save Treatment hours More effect

Gas Cooling(RCS) Skin Protection Safe Treatment Less pain More effective RCS method rapidly cools down the epidermis and have 2 step before & after shot

Gas Cooling(RCS)

Non-ablative fractional hand piece Painless Treatment Deep Penetration Powerful Rejuvenation Aileen has a non-ablative fractional handpiece. Thanks to its high power and high penetration depth for complete combined non-ablative fractional laser.

Non-ablative fractional hand piece

Wide Range of Pulse Duration Aileen possesses a wide range of pulse duration (0.3 ~ 300 ms) which enables the removal of various types of hair follicles located at different depths and rejuvenates the skin in the epidermis. This also enables the treatment of other applications TRT TRT (time required to lower the affected skin s treatment area temperature by 50% after receiving laser treatment.)

Square Pulse Current 400~700V Pulse duration 50ms Aileen possesses a square pulse type based on 18,000 uf high capacity and stable control system which produces high treatment results with fewer side effects. A square pulse is the ideal pulse type as it releases continuous energy during pulse duration then returns the energy to 0 afterwards. If the energy is not constant, treatment results become less effective and it is more likely for side effects to appear afterwards.

Flat Top Beam Profile Flat top beam profile Gaussian beam profile Aileen has flat top beam profile where the energy level is spread out evenly which offers safe treatment and low side effects. This is opposed to a Gaussian beam profile which has an unsteady beam as the distribution of energy is concentrated only in the center.

Fast and Economical treatment Fast treatment using larger spot size (2 ~ 15 mm) Only one zoom handpiece to adjust spot size without requiring changing handpiece. Fast 10 Hz pulse repetition treatment due to high quality capacitor. Fiber optic arm allows for easy treatment (lightweight and can be used in almost any angle)

High power supply Long pulse Nd: YAG requires high power supply in order to effectively treat thinning hair, remove fine wrinkles and thick vascular lesions. The intense energy released from the power supply and capacitors enables the selection of the appropriate treatment parameters. Pulse width Spot size Fluence energy Test result Out put energy 0.3 ms 7 mm 20 J/ cm2 10 ms 10 mm 161 J/ cm2 30 ms 15 mm 89 J/ cm2 50 ms 15 mm 102 J/ cm2

Correlation Skin Type and Wavelength Ⅰ Ⅱ Ⅲ Ⅳ Ⅴ Ⅵ Ruby (694 nm) Alexandrite (755 nm) Diode (800 nm) Nd:YAG (1064 nm)

Vascular theory (Clinical Study on Blue leg veins) Background and Objectives Evaluation of the efficacy, on 1 2 mm blue leg telangiectasia, of a 1,064 nm Nd:YAG laser emitting in a non uniform pulse sequence calculated to consider Met-Hb formation during laser irradiation of a blood vessel. Materials and Methods A 1,064 nm Nd:YAG laser was used in a non uniform pulse sequence mode, fluences: 300 360 J/cm2 spot:2 mm, þ58c contact cooling. The clinical evaluation was performed on 11 female patients, average age: 43 (25 57) years, phototype I VI. All subjects were previously examined with Doppler ultrasound. A treatment site (64 cm) was selected on each patient. The topography of the vessels network was reported on a tracing plastic frame before each session and 6 weeks after the last one. These frames were digitized and the number of vessels was determined using the Digitized Tracing Frames Technique. Side effects were noted before and after every treatment, and 6 weeks after the last one. This study lasted for 10 months. Results and Discussions: Patients tolerated the procedure without anesthesia. Moderate pain, transient erythema and edema, one hyperpigmentation and one matting were noted. There was no hypopigmentation. 55% (P<0.002) vessels clearance after one session, 86% after two sessions (P<0.001), and 98% (P<0.001) after three sessions were obtained. Ontwo patients, the treatment was completed after two sessions with a full clearance. Data reported in this study were obtained thanks to a computerized calculation of vessels clearance. They are similar or superior to those reported in the literature about 1,064 nm Nd:YAG lasers and leg telangiectasia. Conclusions: Since, it was developed to consider the modification of blood absorption and the methemoglobin formation which leads to an increase of the 1.06 mm wavelength absorption, the non uniform pulse mode emphasizes the efficacy of this 1,064 nm Nd:YAG laser concerning the treatment of blue leg veins telangiectasia between 1 and 2 mm. This mode gives the possibility to deliver high energy while preserving the surrounding tissue and leads to a rapid vessel clearance with reduced pain and few side effects when compared to previously published clinical studies using a 1.06 mm laser. Lasers Surg. Med. 32:160 170, 2003. Correspondence to: Serge Mordon, PhD, UPRES Hu 4 2689, INSERM (French National Institute of Health and Medical Research) IFR114, Pavillon Vancostenobel, Lille University Hospital, 59037 LILLE, Cedex, France.

Vascular theory (Clinical Study on Blue leg veins) Summarized results over 11 patients: clearance of the vessels is 55% (P<0.002), 6 weeks after 1 treatment, 86% (P<0.001), 6 weeks after 2 treatments, 98% (P<0.001) 6 weeks after 3 treatments. Correspondence to: Serge Mordon, PhD, UPRES Hu 4 2689, INSERM (French National Institute of Health and Medical Research) IFR114, Pavillon Vancostenobel, Lille University Hospital, 59037 LILLE, Cedex, France.

Vascular theory (Clinical Study on Blue leg veins) Patient 13: Before, after 2 and 3 treatments. Correspondence to: Serge Mordon, PhD, UPRES Hu 4 2689, INSERM (French National Institute of Health and Medical Research) IFR114, Pavillon Vancostenobel, Lille University Hospital, 59037 LILLE, Cedex, France.

Vascular theory (Clinical Study on Blue leg veins) Background and Objectives Millisecond pulsed 1064nm Nd:YAG lasers have developed for the treatment of leg telangiectasias. To date there Have been very few side by side comparison studies of laser versus the gold standard sclerotherapy in treating small leg veins. This study aims to compare a long pulsed Nd:YAG laser with contact cooling to sclerotherapy for treating small diameter leg telangiectasias by evaluating objective clinical effects. Materials and Methods Fourteen patients were selected with leg telangiective ranging from 0.5 to 2 mm at four comparable sites. One site was treatrd with long pulsed Nd:YAG alone, the second received sclerotherapy along, the third laser then sclerotherapy, and the last one sclerotherapy then laser. The patients were followed up at 3 months after the last treatment. Photographs were taken pre-operatively and at 3 months after the last session. They were used for objective and comparative analysis. Statistical analysis was performend using Friedman s test controlling for subject. Results Improvement was tabulated from the photographic assessment on an improvement scale from 0 (no change) To 4(greater then 75% clearing). There were clinical improvements in the laser group then sclerotherapy without statistical significance, side effects were minimal and included hyperpigmentation. Conclusions: This pilot study demonstrates that the long pulse Nd:YAG 1064nm laser can yield results similar to sclerotherapy in the treatment of small leg telangiectasias. Combination of both methods could increase reponse to treatment. Correspondence to: Serge Mordon, PhD, UPRES Hu 4 2689, INSERM (French National Institute of Health and Medical Research) IFR114, Pavillon Vancostenobel, Lille University Hospital, 59037 LILLE, Cedex, France.

Vascular theory (Clinical Study on Blue leg veins) BACKGROUND The long-pulsed 1064-nm Nd:YAG laser (employing varying spot sizes, pulse widths, and fluences) has gained popularity for treating lower extremity blue and red vessels that are less than 4 mm in diameter. OBJECTIVE. To evaluate the efficacy of high-power 50-ms 1064 Nd:YAG laser in the treatment of class I III lower extremity vessels. METHODS Ten female patients (mean age of 39 years) had a 5-cm2 area of veins measuring 0.2 to 3 mm in diameter treated with up to three treatment sessions using a new 1064 Nd:YAG laser, with the end point being 100% vessel clearing after three treatments. Red vessels were treated with a spot size of 1.5 mm, a fluence of 400 to 600 J/cm2, a pulse width of 30 to 50 ms; blue vessels of 1 to 3 mm were treated with a spot size of 3 mm, a fluence of 250 to 370 J/cm2, and a pulse width of 50 to 60 ms. Macrophotographic imaging evaluations by blinded observers using a quartile scale and a patient satisfaction scale were employed to evaluate results. RESULTS At month 3 after the final treatment session, 20% of all vessel types had 50% to 75% improvement. Equal clearing was noted for blue and red vessels. At month 6, 80% of patients had a greater than 75% clearing. Ninety percent of patients were highly satisfied with the treatment results at 6 months. CONCLUSION By varying spot size, fluence, and pulse duration, a long-wavelength 1064-nm Nd:YAG laser can achieve excellent results for treating both blue and red lower extremity vessels that are less than 3 mm in diameter. Correspondence to: Serge Mordon, PhD, UPRES Hu 4 2689, INSERM (French National Institute of Health and Medical Research) IFR114, Pavillon Vancostenobel, Lille University Hospital, 59037 LILLE, Cedex, France.

Theory (Nd:YAG Versus RF-ThermaCool) Background and objective. To improve photoaging skin with laser treatment, multiple sessions have been considered necessary to achieve results comparable with one radiofrequency (RF) treatment. We compared single-treatment improvements obtained by the long-pulse 1064 nm Nd:YAG laser and RF device. Study design/materials and methods. In a split-face study, patients with sagging skin were treated once with laser (left side) and once with RF (right side) energy. Results. Improvement judged by six blinded observers was greater for wrinkles and laxity (30% median) on the laser-treated side and essentially the same with both modalities (15% median) for texture, pores, and pigmentation. Improvement was maintained for at least 2-6 months on both facial sides without adverse effects. Conclusion- With a single treatment, both the long-pulse 1064 nm Nd:YAG laser and ThermaCool RF device provide a modest degree of improvement in both wrinkles and laxity of facial skin and similar improvement in texture, pores, and pigmentation. Authors: Mark B. Taylor a; Inna Prokopenko a Affiliation: a Gateway Aesthetic Institute and Laser Center, Salt Lake City, Utah, USA Published in: Journal of Cosmetic and Laser Therapy, Volume 8, Issue 1 April 2006, pages 17-22

Theory (Nd:YAG Versus RF-ThermaCool) Authors: Mark B. Taylor a; Inna Prokopenko a Affiliation: a Gateway Aesthetic Institute and Laser Center, Salt Lake City, Utah, USA Published in: Journal of Cosmetic and Laser Therapy, Volume 8, Issue 1 April 2006, pages 17-22

Theory (Nd:YAG Versus RF-ThermaCool) Authors: Mark B. Taylor a; Inna Prokopenko a Affiliation: a Gateway Aesthetic Institute and Laser Center, Salt Lake City, Utah, USA Published in: Journal of Cosmetic and Laser Therapy, Volume 8, Issue 1 April 2006, pages 17-22

Collagen Matrix Increased Collagen Increased Chung Buk university hospital

Collagen Matrix Increased Tissue Remodeling Iodine addition Chung Buk university hospital

Treatment Results: Before & After

Tightening 3 treatments @ 2 week intervals 1. Pulse width : 10/10/10ms / Spot size : 15mm / Fluence : 42J/ cm2 / 3pass Mode Face lifting

Skin Rejuvenation Pulse width : 0.3,10/10/10ms, / Spot size : 07,15mm / Fluence : 26-39 J/ cm2 2. Mode : M3,M2

Acne redness 3 treatments @ 1 week intervals 1. Pulse width : 5ms / Spot size : 5mm / Fluence : 132J/ cm2 2. Mode : Genesis -2

Acne redness 5 treatments @ 1 week intervals 1. Pulse width : 5ms / Spot size : 5mm / Fluence : 132J/ cm2 2. Mode : Genesis -2

Acne redness 5 treatments @ 1 week intervals 1. Pulse width : 5ms / Spot size : 5mm / Fluence : 132J/ cm2 2. Mode : Genesis -2

Acne redness 5 treatments @ 1 week intervals 1. Pulse width : 5ms / Spot size : 5mm / Fluence : 132J/ cm2 2. Mode : Genesis -2

Acne redness 2 treatments @ 1 week intervals 1. Pulse width : 5ms / Spot size : 5mm / Fluence : 132J/ cm2 2. Mode : Genesis -2

Blue vein 1 treatments Pulse width : 50ms / Spot size : 5mm Fluence : 168 J/ cm2

Blue vein 1 treatments Pulse width : 50ms / Spot size : 5mm Fluence : 100J/ cm2

Telanaiectasia 1 treatments Pulse width : 8ms / Spot size : 2mm Fluence : 125J/ cm2

Vascular 1 treatments Pulse width : 8ms / Spot size : 2mm Fluence : 125J/ cm2

Telanaiectasia 1 treatments Pulse width : 8ms / Spot size : 2mm Fluence : 125J/ cm2

Telanaiectasia 3 treatments @ 4 week intervals Pulse width : 10ms / Spot size : 2mm Fluence : 150J/ cm2

Hair removal 2 treatments @ 4 week intervals Pulse width : 10/10ms / Spot size : 10mm Fluence : 25J/ cm2

Hair removal 2 treatments @ 4 week intervals Pulse width : 10/10ms / Spot size : 15mm Fluence : 32J/ cm2

Melasma 1 week interval @ 7 treatment Pulse width : 16/35ms / Spot size : 10mm Fluence : 38J/ cm2