ATTUNE Knee System: Cruciate Sacrificing Fixed Bearing

Similar documents
STABILITY & MOTION VS. THE PERSONA KNEE SYSTEM. The Zimmer Persona Knee

ATTUNE Knee System: Stability in Total Knee Replacement

BALANCING THE PATIENT NEED FOR FREEDOM OF MOVEMENT AND JOINT STABILITY

ATTUNE KNEE SYSTEM: SOFCAM CONTACT

Fixed Bearing. stabilityinmotion

Rotating Platform. stabilityinmotion

Evolution. Medial-Pivot Knee System The Bi-Cruciate-Substituting Knee. Key Aspects

Kinematics Analysis of Different Types of Prosthesis in Total Knee Arthroplasty with a Navigation System

ATTUNE KNEE SYSTEM 25% 25% 25% 25% VALUE ANALYSIS BRIEF VALUE SUMMARY UNMET NEEDS IN TOTAL KNEE ARTHROPLASTY

Tibial Base Design Factors Affecting Tibial Coverage After Total Knee Arthroplasty: Symmetric Versus Asymmetric Bases

itotal Customized POSTERIOR-STABILIZED knee replacement system

Stephen R Smith Northeast Nebraska Orthopaedics PC. Ligament Preserving Techniques in Total Knee Arthroplasty

ATTUNE KNEE SYSTEM 30% 30% 20% 20% VALUE ANALYSIS BRIEF VALUE SUMMARY BENEFITS OF TOTAL KNEE ARTHROPLASTY (TKA) UNMET NEEDS IN TKA

Zimmer FuZion Instruments. Surgical Technique (Beta Version)

The challenge. Knee replacement patients report lower levels of satisfaction versus hip replacement patients. Return to sports activity post surgery

Rotating Platform System. Product Rationale

Think isometry Feel balance

TOTAL KNEE ARTHROPLASTY (TKA)

EMPOWERING LIFE THROUGH NATURAL MOTION

LAMINA SPREADER SURGICAL TECHNIQUE

THE ATTUNE REVISION ROTATING PLATFORM KNEE SYSTEM

TKA Gap Planning. Supporting healthcare professionals

NexGen Legacy LPS-Flex Knee. Brochure

ConforMIS, Inc. 28 Crosby Drive Bedford, MA Phone: Fax:

HIGH FLEXION IN CONTEMPORARY TOTAL KNEE DESIGN: A PRECURSOR OF UHMWPE DAMAGE? A FINITE ELEMENT STUDY

Direct Measurement of Graft Tension in Anatomic Versus Non-anatomic ACL Reconstructions during a Dynamic Pivoting Maneuver

Distal Cut First Femoral Preparation

Bicruciate-Retaining or Medial Pivot Total Knee Prosthesis Pritchett 225 Fig. 3. The MP total knee prosthesis. Fig. 1. An anteroposterior radiograph o

DATA & RESEARCH OVERVIEW

TRUMATCH PERSONALIZED SOLUTIONS with the SIGMA High Performance Instruments

Bilateral total knee arthroplasty: One mobile-bearing and one fixed-bearing

THE ATTUNE REVISION FIXED BEARING KNEE SYSTEM

ATTUNE KNEE SYSTEM 25% 25% 25% 25% VALUE ANALYSIS BRIEF VALUE SUMMARY UNMET NEEDS IN TOTAL KNEE ARTHROPLASTY

Retrospective Study of Patellar Tracking in an Anatomical, Motion Guided Total Knee Design. Adam I. Harris, M.D. & Michelle Ammerman

Consistency in U2 Knee System over Time

Knee Revision. Portfolio

Intramedullary Tibial Preparation

Extramedullary Tibial Preparation

Gold standard of a TKA. Conflicting goals? POLYETHYLENE WEAR THE SOLUTION: MOBILE BEARING KNEES. MOBILE BEARING A totally new approach (1977)

NexGen CR-Flex and LPS-Flex Knees. Design Rationale

RESECTION GUIDE SYSTEM. TRUMATCH Personalized Solutions Surgical Technique with ATTUNE Knee INTUITION Instruments

20 Kinematics of Mobile Bearing Total Knee Arthroplasty

Mako Partial Knee Patellofemoral

STIFFNESS AFTER TKA PRE, PER AND POST OPERATIVE CAUSING FACTORS

Estimating Total Knee Arthroplasty Joint Loads from Kinematics

Surgical Technique. VISIONAIRE FastPak Instruments for the LEGION Total Knee System

why bicompartmental? A REVOLUTIONARY ALTERNATIVE TO TOTAL KNEE REPLACEMENTS

Frontal Plane Kinematics After Mobile- Bearing Total Knee Arthroplasty

Mako Partial Knee Medial bicompartmental

A Systematic Review on Performance of the Vanguard Complete Knee System

Surgical Technique. Hinge Disassembly and Rebuild Technique

The Cruciate Ligaments in Total Knee Arthroplasty

Biomechanics of the Knee. Valerie Nuñez SpR Frimley Park Hospital

Rotaglide+ TM. Total Knee System Product overview

Knee Replacement Implants

INTUITION INSTRUMENTS SURGICAL TECHNIQUE

JOINT RULER. Surgical Technique For Knee Joint JRReplacement

BIOMECHANICAL MECHANISMS FOR DAMAGE: RETRIEVAL ANALYSIS AND COMPUTATIONAL WEAR PREDICTIONS IN TOTAL KNEE REPLACEMENTS

INTUITION INSTRUMENTS SURGICAL TECHNIQUE

Comparison of high-flex and conventional implants for bilateral total knee arthroplasty

CLASSIFICATION OF MOBILE BEARING KNEE DESIGN: MOBILITY AND CONSTRAINT

Revolution. Unicompartmental Knee System

CONTRIBUTING SURGEON. Barry Waldman, MD Director, Center for Joint Preservation and Replacement Sinai Hospital of Baltimore Baltimore, MD

PIN GUIDE SYSTEM SURGICAL TECHNIQUE. with the SIGMA High Performance Instruments System. This publication is not intended for distribution in the USA.

Surgical Technique. VISIONAIRE Disposable Instruments for the LEGION Total Knee System

BOOK CHAPTERS PUBLICATIONS

TOTAL KNEE ARTHROPLASTY SYSTEM

RECLAIM REVISION HIP SYSTEM

SIGMA High Performance Partial Knee. Unicondylar. Surgical Technique

ANATOMIC Fixed Bearing Total Knee System Posterior Stabilised Version Cemented or Cementless Options

Constrained Posterior Stabilized (CPS) Surgical Technique

Instrumentation Options

Full Function, Faster Medial-Pivot

Over 20 Years of Proven Clinical Success. Zimmer Natural-Knee II System

Single Axis Revision Knee System

Effects of Posteromedial Vertical Capsulotomy on the Medial Extension Gap in Cruciate-retaining Total Knee Arthroplasty

HP KNEE EXTRACTION Instrumentation. Product Overview

Masterclass. Tips and tricks for a successful outcome. E. Verhaven, M. Thaeter. September 15th, 2012, Brussels

Constrained Posterior Stabilized (CPS)

Presented By Dr Vincent VG An MD BSc (Adv) MPhil Dr Murilo Leie MD Mr Joshua Twiggs BEng Dr Brett A Fritsch MBBS FRACS (Orth) FAOrthA.

CLINICAL FINDINGS USING THE VERASENSE KNEE SYSTEM THE INTELLIGENT CHOICE FOR FLEXION STABILITY

A study of functional outcome after Primary Total Knee Arthroplasty in elderly patients

THE PERSONALIZED KNEE

Zimmer Gender Solutions Natural-Knee Flex System

INSTRUMENTS. Product Rationale

Vanguard. Total Knee System

Zimmer Patient Specific Instruments. Surgical Techniques for NexGen Complete Knee Solution

Triathlon Knee System. Universal Baseplate Surgical Protocol

Persona. The Personalized Knee. Trabecular Metal Tibia. Surgical Technique

ZIMMER NEXGEN CRUCIATE RETAINING (CR) AND LEGACY KNEE POSTERIOR STABILIZED (LPS) TRABECULAR METAL MONOBLOCK TIBIAS. Surgical Technique Addendum

TRUMATCH PERSONALIZED SOLUTIONS with the SIGMA High Performance Instruments

ACTIS. TOTAL HIP SYSTEM Approach Active Patients with Confidence DESIGN RATIONALE

MIS Cemented Tibial Component

INSTRUMENTS. Design Rationale

NexGen CR-Flex Fixed Bearing Knee. Surgical Technique

Zimmer NexGen. LPS-Flex Fixed Bearing Knee. Surgical Technique. Designed to accomodate resumption of high-flexion daily activities

Contact stress at the post-cam mechanism in posterior-stabilised total knee arthroplasty

Effect of Total Knee Replacement Conformity on Articular Constraint in Mechanical Testing

Fixed Bearing Knees Function with Wear Resistance

Transcription:

ATTUNE Knee System: Cruciate Sacrificing Fixed Bearing Christel Wagner Knee Development Manager DePuy Synthes Joint Reconstruction INTRODUCTION: The purpose of a well functioning posterior cruciate ligament (PCL) in a native knee is to prevent the femur from translating too far anteriorly or the tibia from translating too far posteriorly. The PCL also guides posterior rollback of the femur. A surgeon who prefers to retain the posterior cruciate ligament (PCL) generally utilizes a cruciate retaining (CR) component, while a surgeon who excises the PCL generally utilizes a posterior stabilized (PS) component, replacing the PCL with a cam and spine. A subset of surgeons utilize a cruciate sacrificing (CS) procedure in which the PCL is released but is not replaced by a cam and spine. This procedure requires certain implant design considerations in order to provide the resistance for translation that is typically provided by either the PCL in a CR knee or the cam and spine in a PS knee. The ATTUNE TM Knee System CR fixed bearing (FB) insert has been designed with the surgeon who uses a CS procedure in mind, and it has been cleared by the FDA for a CS application. HISTORICAL REVIEW OF CS KNEES One of the historical challenges of excising the PCL has been the effect on the flexion space and anteriorposterior (A/P) stability. Numerous studies have demonstrated that once the PCL is removed the flexion space can open up by several millimeters 1, 2 and A/P translation increases. 3, 4 To address these challenges, two distinct design approaches were considered for CS applications. The first approach was the development of a rotating platform (RP) device that incorporated a high degree of femoral to insert conformity. This device, called the Low Contact Stress Knee (LCS TM Knee System), enabled size to size insert to femur matching. To achieve this conformity, a decoupling of rotational forces was built into the design by allowing flexion and extension to occur on the top side of the insert and internal and external rotation to occur on the backside (Figure 1). The system also incorporated gap balancing instruments to help balance the increased flexion space that occurred with an excised PCL. Literature has shown that this type of design was able to attenuate anteroposterior translation when the PCL was removed. 5 The second approach to CS applications was directed at fixed bearing (FB) knees. Due to rotation and flexion occurring on the top side of the insert, and the articular surface accommodating several sizes of femoral Figure 1 Figure 2 components, a different approach was taken from CS RP Knees. This new approach incorporated a uniquely designed polyethylene insert that featured a raised anterior lip (Figure 2). This was first launched within the Natural-Knee System, 6 with the raised anterior lip acting as a ramp to provide subluxation resistance. 1

CURRENT DESIGN CHALLENGES WITH FIXED BEARING CS KNEES: Based upon the success of the FB Natural-Knee Ultracongruent insert, the industry began widely adopting a raised anterior lipped polyethylene insert for fixed bearing CS applications. Mid-term survivorship with these types of inserts has been good. 6 However, to begin addressing the 15-20% of patients who are dissatisfied after TKA, 7 it is important to understand the limitations of these devices and how they may be improved. The first limitation is associated with the raised anterior lip. In many cases the raised anterior lip does not attenuate A/P sliding as compared to a standard CR insert. 8 The anterior lip acts as a deterrent to subluxation. This is a result of compromises that have been accepted into current FB constructs. In these FB constructs, the tibial tray and insert sizes match and the femur is allowed to be upsized or downsized on top of the insert. As a result, FB CS inserts must be designed to accommodate articulation with a larger or smaller sized femur. This creates a compromise in femoral to insert conformity. This compromise allows for the possibility of the femoral component sliding forward rather than rolling back before it interacts with the anterior ramp of the CS polyethylene. DePuy Synthes Joint Reconstruction testing has shown that the sliding distance of a femoral component on a raised anterior lipped insert, is similar to a standard CR insert. 8 This demonstrates that the anterior lip is not helping patients improve their stability throughout flexion but instead acting only as a barrier to subluxation. The second limitation of current CS FB knees is related to the sagittal curvature of the femoral component. Data has shown there is relatively no difference in the extension gap when comparing knees with and without a PCL. 1,2 However, as the knee flexes to 45 degrees and 90 degrees, the flexion gap increases significantly in PCL deficient knees (Figure 3). When reviewing most current TKA designs, there is generally a significant, sudden reduction in the femoral radius of curvature between 30 and 60 degrees. In some designs, such as Triathlon, this transition occurs at 10 degrees. 9 This sudden decrease in the femoral radius of curvature has the potential to increase the femoral component s ability to slide forward on the polyethylene during mid-flexion, 9 especially in a PCL deficient knee where the flexion gap increases with deeper flexion. 1 Joint component gap (mm) 21 19 17 15 13 11 9 CR PS 0 10 45 90 135 Knee flexion angle ( ) Figure 3: Graph showing the flexion space opening up in a PS knee versus a CR knee as the knee flexes The last limitation is with regard to gap balancing. While many companies in the industry have begun providing femoral components with consistent A/P increments in between femoral sizes, there is still a need for inserts that provide fine tune options for gap balancing. In many cases tibial inserts designed for a CS application have inconsistent increments between thicknesses. To address these challenges in FB CS knees, the ATTUNE Knee has focused on improving the following: Femoral to Insert Conformity for Fixed Bearing CS Applications Femoral Geometry for Fixed Bearing CS Applications Knee System Sizing and Balancing Features for CS Surgeons Subluxation Resistance 2

ATTUNE CR FEMORAL TO INSERT CONFORMITY FOR FIXED BEARING CS APPLICATIONS: To address limitations with an insert that can accommodate several different femoral sizes, the ATTUNE System incorporates a patented fixed bearing central locking mechanism design that works across all sizes to optimize patient fit and kinematics. This design, the LOGICLOCK TM Tibial Base, allows for the insert to always match the femoral component. In a FB CS application this enables increased sagittal conformity and stability. To demonstrate an increase in A/P stability with the ATTUNE CR versus a raised anterior lipped polyethylene construct, a test was conducted to compare the ATTUNE CR insert to the SIGMA Knee Curved Plus (CVD+) insert (Figure 4). The SIGMA CVD+ design features a higher raised anterior lip than the ATTUNE CR insert design. The testing that was performed assessed the amount of force required to move the femoral component anteriorly and posteriorly on the tibial insert. As shown in the graphs below (Figure 5), the ATTUNE CR insert provided similar or more resistance against anterior translation than the SIGMA CVD+ insert at different flexion angles. 8 This indicated a greater force is required to move the ATTUNE CR Femoral component anteriorly on the tibial insert. Figure 4: Depiction of in vitro A/P stability test CR Anterior Stability 400 400 CR Anterior Stability 350 350 300 300 250 250 A/P Face (N) 200 200 150 150 A/P Face (N) 100 100 ATTUNE CR-FB 50 SIGMA CR-CVD+ 50 ATTUNE CR-FB SIGMA CR-CVD+ 0 0 2 4 6 8 10 12 0 2 4 6 8 10 12 0 A/P Translation (mm) A/P Translation (mm) Figure 5: A/P stability of CS fixed bearing designs (ATTUNE CR and SIGMA CVD+) at 15 and 90 degrees of flexion. 3

ATTUNE FEMORAL GEOMETRY FOR FIXED BEARING CS APPLICATIONS: To address the limitations associated with a reduction in the femoral radius of curvature leading to instability, 9 the ATTUNE Knee femoral components have incorporated a gradually reducing radius of curvature (ATTUNE GRADIUS Curve). The following data shows the gradually reducing conformity ratio of the ATTUNE CR in comparison to the SIGMA Knee, NexGen and Triathlon (the conformity ratio is defined as the ratio of the femoral radius to the polyethylene insert radius). The data demonstrates higher stability with the ATTUNE CR throughout the range of motion, while still providing rotational freedom in deeper flexion (Figure 6). 0º 15º 30º 60º 90º ATTUNE CR FB 0.88 0.83 0.77 0.66 0.67 SIGMA CR FB 0.76 0.76 0.76 0.47 0.47 NexGen CR 0.54 0.54 0.54 0.31 0.31 Triathlon CR 0.38 0.22 0.22 0.22 0.22 Figure 6: Sagittal conformity ratios for the ATTUNE CR Fixed Bearing, SIGMA CVD Fixed Bearing, NexGen CR Fixed Bearing, and Triathlon CR Fixed Bearing from 0 to 90 degrees flexion. After the ATTUNE GRADIUS Curve, which occurs from 5 to 65 degrees in the CR knee, there is another feature which further works to the benefit of a surgeon in a CS procedure. After 65 degrees, the ATTUNE CR femoral component incorporates a brake radius. The brake radius acts as a cam and spine for the CR knee. This is accomplished by slightly increasing the femoral radius of curvature from 65-105 degrees, in turn helping the knee to roll back and reduce anterior slide. This is especially important in the absence of a PCL. To evaluate the ATTUNE CR femoral geometry, Fitzpatrick et al. (2012) analyzed the influence of implant geometry on the inherent stability, motion, and contact mechanics of the knee joint. 9 Specifically, A/P and internal-external (IE) motions of the knee in four current TKA implant designs (Triathlon [Stryker Orthopaedics, Mahwah, NJ], NexGen [Zimmer, Warsaw, IN], ATTUNE Knee System [DePuy Synthes Joint Reconstruction, Warsaw, IN], and SIGMA Knee System [DePuy Synthes Joint Reconstruction, Warsaw, IN]) were compared. Each design was assessed for A/P stability during a step-down (high A/P shear) and rotational stability/freedom during Medial A/P Position (mm) 14 12 10 8 6 4 2 0 0 Triathlon NexGen ATTUNE SIGMA 25 50 75 100 Stance-phase Gait Cycle (%) Figure 7: This graph shows the A/P movement of Triathlon, NexGen, the ATTUNE Knee, and SIGMA Curved throughout the stance phase of gate. Note: The more vertical variation in a line, the greater the A/P movement stance-phase gait (high IE torque). The ATTUNE Knee System was shown to provide a greater degree of A/P stability than other designs in the marketplace while avoiding excessive rotational constraint. The result was a balanced level of stability and freedom that more closely matches that found in the native knee. 10 4

ATTUNE KNEE SYSTEM SIZING AND BALANCING FEATURES FOR CS SURGEONS: Knee arthroplasty is considered to be a soft tissue procedure. 11,12 Balancing the flexion and extension gaps is extremely important in achieving optimal stability and motion, especially in PCL deficient knees. Significant research and development was spent on the ATTUNE System femoral and tibial insert sizing and geometry so that surgeons would be enabled to retain or sacrifice the PCL. This included working with anthropometric research experts at the University College Dublin (UCD) to take advantage of their extensive database of bone scans. This database represented a global patient population of Caucasian, Indian, Chinese, and Japanese ethnicities. 13 To accommodate a worldwide population, the ATTUNE Knee System provides a comprehensive femoral size offering including 10 standard and 4 narrow femoral sizes, in consistent 3 mm A/P increments and 1 mm insert thickness increments in the smaller thicknesses. (Figure 8). This sizing range combined with INTUITION Instruments and the ability to get precise implant placement (Figure 9) enable the restoration of posterior femoral offset and flexion gap balance in a CS application. +1.5 mm Hole Center Line Hole -1.5 mm Hole Anterior Down Referencing Pin Holes Posterior Up Referencing Pin Holes Narrow Size Reference Cutout Figure 8: 1 mm insert thickness increments (left) and 3 mm femoral A/P increments (right) Figure 9: INTUITION TM Instruments 4-in-1 cutting block provides 1.5 mm positional shift SUBLUXATION RESISTANCE: The comprehensive offering of 3 mm femoral A/P increments, 1 mm insert increments, and precise gap balancing tools, works together in a CS application to provide better or equal frank subluxation resistance with ATTUNE CR vs. a raised anterior lip polyethylene construct. For example: When looking at the SIGMA Knee, there is the opportunity to downsize the femoral component, using anterior referencing. This opens up the flexion space by 4 mm in a worst case scenario. In addition there is also an opportunity to downsize the thickness of the insert by 2.5 mm. In a worst case scenario this would create a 6.5 mm gap mismatch (4 mm femoral + 2.5 mm insert). To address this, SIGMA incorporates a CVD+ insert to prevent subluxation by providing an anterior lip height of 7.5 mm. In a worst case mismatch scenario (a downsized femur and a thinner insert) the height of the anterior lip of a CVD+ insert would still prevent dislocation from occurring: 7.5 mm Anterior lip height 6.5 mm mismatched gap = 1 mm remaining preventing dislocation. With ATTUNE CR, when using the same anterior referencing technique above, the largest mismatch with a CR femur that can occur is 3 mm. With the first 4 tibial insert thicknesses, the maximum polyethylene thickness mismatch that can occur is 1 mm. The worst case scenario mismatch for the ATTUNE Knee comes out to 4 mm (3 mm femoral + 1 mm insert). The ATTUNE CR insert provides an anterior lip height of 6 mm. Therefore, in a worst case mismatch scenario (a downsized femoral component and a thinner tibial insert) the height of an anterior lipped ATTUNE CR tibial insert would provide 5

more dislocation resistance than a SIGMA CVD+ tibial insert: 6 mm Anterior lip height 4 mm mismatched gap = 2 mm remaining, preventing dislocation. In the event that a thicker ATTUNE CR insert is being used, and the jump between thickness increments goes up to 2 mm, ATTUNE CR would still provide the same frank subluxation resistance as a SIGMA CVD+ tibial insert: 6 mm ATTUNE CR anterior lip height 5 mm mismatched gap (2 mm insert + 3 mm femur) = 1 mm remaining preventing dislocation (Figure 10). SIGMA CVD+ (insert > 10 mm) ATTUNE (insert < 8 mm) ATTUNE (insert > 10 mm) Anterior Vertical Rise 7.5 mm 6.0 mm Max femoral A/P size mismatch (anterior down) 4 mm* 3 mm 3 mm Max polyethylene thickness mismatch 2.5 mm 1 mm 2 mm Total Possible Mismatch 6.5 mm 4 mm 5 mm Resistance to Frank Subluxation (Anterior Vertical Rise - Total Mismatch) 1 mm 2 mm 1 mm *Utilizing SIGMA size 3-5 Figure 10: Resistance to Frank Subluxation for SIGMA CVD+ and ATTUNE CR CONCLUSION: While current industry CS designs are characterized by an increased anterior lip height, ATTUNE CR has been designed with the intent of helping surgeons reduce A/P instability in CS applications without compromising rotational freedom in deep flexion. Through proprietary technologies like the ATTUNE GRADIUS Curve, LOGICLOCK Tibial Base, and INTUITION Instruments, the ATTUNE Knee System provides surgeons with a CS implant that maintains optimized kinematics for improved stability and motion when the PCL is absent. All these benefits are achieved without the need for increased inventory or additional insert options. REFERENCES 1. Matsumoto T, Kuroda R, Kubo S, Muratsu H, Mizuno K, Kurosaka M. The intra-operative joint gap in cruciate-retaining compared with posteriorstabilised total knee replacement. J Bone Joint Surg Br. 2009 Apr;91(4):475-80. 2. Mihalko WM, Krackow KA. Posterior cruciate ligament effects on the flexion space in total knee arthroplasty. Clin Orthop Relat Res. 1999 Mar;(360):243-50. 3. Siebel T, Käfer W. In vitro investigation of knee joint kinematics following cruciate retaining versus cruciate sacrificing total knee arthroplasty. Acta Orthop Belg. 2003 Oct;69(5):433-40. 4. Shoji H, Wolf A, Packard S, Yoshino S. Cruciate retained and excised total knee arthroplasty. A comparative study in patients with bilateral total knee arthroplasty. Clin Orthop Relat Res. 1994 Aug;(305):218-22. 5. Banks SA, Hodge WA. 2003 Hap Paul Award Paper of the International Society for Technology in Arthroplasty. Design and activity dependence of kinematics in fixed and mobile-bearing knee arthroplasties. J Arthroplasty. 2004 Oct;19(7):809-16. 6. Hofmann AA, Tkach TK, Evanich CJ, Camargo MP. Posterior stabilization in total knee arthroplasty with use of an ultracongruent polyethylene insert. J Arthroplasty. 2000 Aug;15(5):576-83. 7. Bourne RB, Chesworth B, Davis A, Mahomed N, Charron K. Comparing patient outcomes after THA and TKA: is there a difference? Clin Orthop Relat Res. 2010 Feb;468(2):542-6. 8. DePuy Synthes Joint Reconstruction Internal: WR100393 and WR080330. 9. Fitzpatrick CK, Clary CW, Rullkoetter PJ. The Influence of Design on TKR Mechanics During Activities of Daily Living. Poster No. 2034. 58th Annual Meeting of the Orthopaedic Research Society. 2012, San Francisco, CA. 10. Sathasivam & Walker, The Conflicting Requirements of Laxity and Conformity in Total Knee Replacement, J. of Biomechanics, 1999, 32, pp. 239-247 11. Heesterbeek P. Mind the gaps! Clinical and technical aspects of PCLretaining total knee replacement with the balanced gap technique: an academic essay in Medical Science. Acta Orthop Suppl. 2011 Oct;82(344):1-26. 12. Dennis DA, Komistek RD, Kim RH, Sharma A. Gap balancing versus measured resection technique for total knee arthroplasty. Clin Orthop Relat Res. 2010 Jan;468(1):102-7. 13. Courtis, P., Heldreth, M., FitzPatrick, D. Probabilistic Modeling of Femoral Component Overhang Poster Number 1988. 58th Annual Meeting of the Orthopaedic Research Society. 2012, San Francisco, CA. 6

Third party trademarks used herein are trademarks of their respective owners. DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN 46582 T. +1 (800) 366-8143 www.depuysynthes.com DePuy Synthes Joint Reconstruction, a division of DOI 2014 0612-82-513 (Rev. 1) EO 2/14