Bio-degradable osteosynthesis system in treatment of mandibular parasymphysis fractures

Similar documents
RapidSorb Resorbable Tacks. Resorbable Fixation System.

Three Dimensional Titanium Mini Plates in Management of Mandibular Fractures

RAPIDSORB RAPID RESORBABLE FIXATION SYSTEM. A new resorbable approach to Alveolar bone augmentation

The Skeletal Stability of Maxillary Advancement in Combination with Bilateral Sagittal Split Ramus Osteotomy. Mohamed Diaa Z.

Surgical technique. IMF Screw Set. For temporary, peri opera tive stabilisation of the occlusion in adults.

Technique Guide. Compact 2.0 LOCK Mandible. The locking system for the mandible.

Biodegradable plates and screws in oral and maxillofacial surgery Buijs, Gerrit Jacob

Mandible External Fixator II. Provides treatment for fractures of the maxillofacial area.

New innovations in craniomaxillofacial fixation: the 2.0 lock system

RAPIDSORB RAPID RESORBABLE FIxATION SySTEm

Inion CPS. Biodegradable Fixation System. Product Overview

Mandible fracture - Management. Dr Dinesh Kumar Verma OMFS SDCRI, SGNR

PROXIMAL TIBIAL PLATE

Low Profile Neuro Plating System. Surgical Technique

Technique Guide. IMF Screw Set. For intermaxillary fixation.

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

Advances in skeletal stabilization techniques have

Pinit Plate Small Bone Fusion System Bone Plate & Screw System

WINSTA-C. Clavicle Plating System

MatrixNEURO. The next generation cranial plating system.

DISTRACTION PRODUCT OVERVIEW. For a wide variety of facial applications

External Skeletal Fixation (ESF)

Departement of Stomatology, The Second Hospital of Lanzhou University, 82 Cuiyingmwen, Chengguan District, Lanzhou City, Gansu Province, China

Zimmer Small Fragment Universal Locking System. Surgical Technique

IMF Screw Set. For temporary, peri opera tive stabilisation of the occlusion in adults.

MatrixNEURO. The next generation cranial plating system.

Locking Proximal Humerus Plate. For complex and unstable fractures.

Scholars Journal of Medical Case Reports

THE USE OF TEMPORARY ANCHORAGE DEVICES FOR MOLAR INTRUSION & TREATMENT OF ANTERIOR OPEN BITE By Eduardo Nicolaievsky D.D.S.

Elbow Hinge Fixator. Guided Flexion/Extension for Unstable Elbow Fractures.

Lapidus Arthrodesis System Instructions for Use

2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

low ProfIle neuro PlaTIng system

OBSOLETED. LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

SYNPOR POROUS POLYETHYLENE IMPLANTS. For craniofacial and orbital augmentation and reconstruction

DOWNLOAD OR READ : RIGID FIXATION FOR MAXILLOFACIAL SURGERY PDF EBOOK EPUB MOBI

Two-Year Follow-up on the Use of Absorbable Mesh Plates in the Treatment of Medial Orbital Wall Fractures

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plates. Part of the Synthes locking compression plate (LCP) system.

Resorbable Implant Technology

Distal Radius Plate 2.4/2.7 dorsal and volar

For the Attention of the Operating Surgeon: IMPORTANT INFORMATION ON THE MATRIXRIB FIXATION SYSTEM

RFS. Resorbable Fixation System SURGICAL TECHNIQUE

Technique Guide Small Bone Fusion System

CASE REPORT. CBCT-Assisted Treatment of the Failing Long Span Bridge with Staged and Immediate Load Implant Restoration

CHAPTER. 1. Uncontrolled systemic disease 2. Retrognathic jaw relationship

Technique Guide. RapidSorb Rapid Resorbable Fixation System. A new resorbable approach to Alveolar bone augmentation.

The Calcaneal Plate. The Synthes non-locking solution for the Calcaneus.

3.5 mm LCP Extra-articular Distal Humerus Plate

AcUMEDr. BIoTRAKt Resorbable Pin

Case Report. Orthognathic Correction of Class II Open Bite. Using the Piezoelectric System and MatrixORTHOGNATHIC Plating System.

Femur Condylar Plate System Procedural Steps.

Suuronen R, Pohjonen T, Hietanen J. A 5-year in vitro and in vivo study of biodegradation of polylactide plates J Oral Maxillofac Surg 56:604, 1998

Technique Guide. 3.5 mm LCP Olecranon Plates. Part of the Synthes locking compression plate (LCP) system.

EndoWorld OSM19-5-E/ MegaFix. The Bioabsorbable Interference Screw. KARL STORZ SPORTS MEDICINE, Inc.

LOW PROFILE NEURO. This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

Surgical Technique. Distal Humerus Locking Plate

Surgical Technique. Clavicle Locking Plate

ORIGINAL ARTICLE. deformity is often made difficult because of the inherent

Bio XT Maximising the Material Performance of Resorbable Implants

Compact 2.0 LOCK Mandible. The locking system for the mandible.

LCP Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment Locking Compression Plate (LCP) system.

LCP Metaphyseal Plates. For extra-articular fractures.

CRANIAL RECONSTRUCTION SOLUTIONS

Rapid ResoRbable fixation system

.org. Tibia (Shinbone) Shaft Fractures. Anatomy. Types of Tibial Shaft Fractures

A locking plate system that expands a surgeon s options in trauma surgery. Zimmer NCB Plating System

Mandible External Fixator II. Provides treatment for fractures of the maxillofacial area.

NCB Proximal Humerus Plating System

INTERNAL FIXATION OF THE METACARPALS AND PHALANGES P. BURGE

Bioabsorbable osteofixation for orthognathic surgery

Technique Guide KISSloc Suture System

CS 2.0. Product information. Intelligent innovations for a better life.

Comparative Study of the Efficacy of Titanium Lag Screw and Titanium Miniplates for Internal Fixation of Anterior Mandibular Fractures

Contemporary Implant Dentistry

Resorbable Implant Technology

AcUMEDr. LoCKING CLAVICLE PLATE SYSTEM

LCP Distal Humerus Plates

Titanium Wire With Barb and Needle

Headless Compession Screw 2.5 / 3.0

A Novel Technology for Maxillomandibular Fixation: Universal SMARTLock Hybrid MMF

2.7 mm/3.5 mm LCP Distal Fibula Plate System. Part of the Synthes locking compression plate (LCP) system.

MatrixNEURO Cranial Plating System

MetaFix Ludloff Plate

LCP Medial Proximal Tibial Plate 4.5/5.0. Part of the Synthes LCP periarticular plating system.

Headless Compession Screw 4.5 / 6.5 SURGICAL TECHNIQUE. Titanium or Stainless Steel. Cannulated Headless Design. Multiple Thread Options.

Technique Guide. Locking Attachment Plate. For treatment of periprosthetic fractures.

Titanium Wire with Barb and Needle. Surgical Technique Guide for Canthal Tendon Procedures.

Clinical Study Open Reduction of Subcondylar Fractures Using a New Retractor

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plate Aiming Instruments. Part of the 3.5 mm LCP Percutaneous Instrument System.

Technique Guide. SynPOR Porous Polyethylene Implants. For craniofacial and orbital augmentation and reconstruction.

Unusual transmigration of canines report of two cases in a family

O.S.2-C. Compression staple PEEK

LOGIC SURGICAL TECHNIQUE GUIDE. In d i c at i o n s. Co n t r a i n d i c at i o n s. Mandibular Distraction System

Medartis Product Overview MODUS

Dental Implants: A Predictable Solution for Tooth Loss. Reena Talwar, DDS PhD FRCD(C) Oral & Maxillofacial Surgeon Associate Clinical Professor

Technique Guide. 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

Conventus CAGE PH Surgical Techniques

EVALUATION OF MODIFIED EXTRAORAL TECHNIQUE IN ZYGOMATIC ARCH EXAMINATION

Transcription:

Al Am een J Med Sci 2012; 5(4): 371-375 US National Library of Medicine enlisted journal ISSN 0974-1143 ORIGI NAL ARTICLE C O D E N : A A J MB G Bio-degradable osteosynthesis system in treatment of mandibular parasymphysis fractures Sameer Choudhari 1, Sulabha A.N 2*, Warad NM 1, A.P.Krishna 3 and Salim Mujawar 1 1 Department of Oral Maxillofacial Surgery, 2 Department of Oral Medicine and Radiology, Al-Ameen Dental College and Hospital, Athani Road, Bijapur-586108 Karnataka, India and 3 Department of Oral Maxillofacial Surgery, ACPM Dental College, Dhule, Maharashtra, India Abstract: Background: Rigid internal fixation using metal compression plates, miniplates, micro plates etc are established system in treatment of facio-maxillary trauma. Most of the time results are satisfactory and are in vague. Until recently, unfortunately these well established treatments have certain inherent disadvantages like foreign body sensation, tissue reaction, secondary infection, galvanic current reaction etc. Bio-resorbable plating system has been used in the present study in selected patients and results have found to offer better advantages than routine metal plates. Objective: This study aims to demonstrate the biocompatibility and benefits of bioresorbable plating system with surrounding soft tissue and bone. Methods: The present study uses bioresorbable polyl lactic acid (PLLA) plating system to treat the mandibular fractures. These plates were assessed for biodegradability using ultrasonographic aid for period of 1 year. Results and Conclusion: We found at end of 1 year thickness of plate changed markedly with decrease in size of plates and screws with fading of bur holes. Hence these materials are satisfactory in treatment of maxillofacial fractures offering better advantage than conventional metal plating system Keywords: Maxillofacial trauma, Mandibular fractures, Bioresorbable plates, Ultrasonography Introduction Internal fixation of maxillofacial fracture is indicated after open reduction. Since 1970 fixation devices have developed to achieve adequate strength, rigidity as well as biocompatibility with satisfactory bone healing at fracture site. Titanium bone plates are currently used extensively for fixation of facial fractures in form of compression plates, micro plates and miniplates and these several disadvantages persists including palpability, hardware loosening, temperature sensitivity, fretting corrosion, interference with radiographic imaging and subsequently need for a second surgery for removal of implant. In order to overcome some of the problems a new class of materials namely bioresorbable polymers have been developed for the use in internal fixation of maxillofacial injuries. These materials are in use since early eighties as the fields of bioresorbable materials have matured, many devices have become available to maxillofacial surgeon including pin, suture materials, plates etc. These materials undergo resorption, thereby achieving the advantage of titanium fixation without the associated long term problems. These bio-resorbable polymer plates have been chosen to treat selected number of patients with vertical undisplaced fractures of mandible in the parasymphysis region and evaluated our own observations regarding biodegradability of plates and screws by ultrasonographic aid. Aims and objective: 1. The purpose of the present study is to highlight the possible benefits of bioresorbable plate and screw fixation system in mandibular parasymphysis fracture. 2. To demonstrate biocompatibility of bioresorbable plating system with surrounding soft tissue and bone. 3. The purpose of this study is also to investigate the use of ultrasound for detection and monitoring the degradation process of bio-resorbable plating system for period of twelve months. 2012. Al Ameen Charitable Fund Trust, Bangalore 371

Material and Methods The bio-degradable materials used nowadays for fracture fixation are high molecules weight polymers. The bio-degradable material used in the present study is the poly-l lactic acid (PLLA). It has ideal strength properties for internal fixation of fracture (bending strength, is up to 240 mega Pascal). This is hydrophobic, highly crystalline, resorption time is long, and during degradation it forms crystals which take considerable time to resorb [1]. The other bioresorbable materials are polydioxanone (PDS), poly lactic acid (PLA), poly glycolic acid (PGA) etc. These plating materials are well tolerated by living tissue; mild inflammatory reactions are seen around the implants. Local swelling, sinus formation have been reported in human beings [2]. Ten patients reporting to department of oral and maxillofacial surgery requiring open reduction and internal fixation were selected. A four holed plate with 2.5 mm of thickness were used for fracture reduction. The vertical fracture in the body of mandible at parasymphysis region, single, comminuted, compound fractures was selected in patient age ranging from 20-45 years. (Fig -1) Risdon s incision (submandibular incision) (Fig- 2) was taken for all the patient to expose the fracture site followed by 8mm screw application on 4 holed extended miniplate. (Fig -3, Fig- 4) Post operative healing and fracture stability was achieved in the entire patients except in one case where the implant related fluctuant swelling was seen at end of 4 months. Later swelling was subsided by antibiotic regimen, healing of bone was undisturbed. Ultrasound with 5 MHz linear probe was used at implanted site of plate fixation at interval of 2 month 4 month 8 month and 12month to assess the biodegradability. Fig-3: Loading of the screw before application Fig-1: CT scan 3D reconstruction images of fracture parasymphysis of the mandible Fig-4: Adaptation of 4 holed miniplates at fractured site Fig-2: Submandibular incision Fig-5: USG views of plates and screws in mandibular parasymphysis region after two months of insertion 2012. Al Ameen Charitable Fund Trust, Bangalore 372

At the end of 2 months (Fig-5) no significant ultrasonographic feature were noted. At the end of 4 months (Fig-6) ultrasonographically outer border of plate was precisely limited as a hyperechoic periphery in comparison to hypoechoic centre. No change in the diameter of bur holes in bone was seen, echoes were much appreciable at this stage. No implant related infection, swelling seen. Degradation started with water in take, producing increase in the distance between the hyperechoic outer borders with breaking in the lines, further at the end of 8 months (Fig-7) maximum of volume was reached, and hypoechoic structure was seen at the site of the plate. Bur holes were fading, plates and screws appeared less echoic compared to the fourth month scan. Healing of the bone was satisfactory at this period with out any complications. At the end of 1 year length (Fig-8) thickness of plate changed markedly with decrease in the size of plate, screws and bur holes and region appeared less echoic. Fig-6: USG views of plates and screws in mandibular parasymphysis region after four months of insertion Fig-7: USG views of plates and screws in mandibular parasymphysis region after eight months of insertion Results and Discussion Fig-8: USG views of plates and screws in mandibular parasymphysis region after twelve months of insertion Treatment methods in maxillofacial fracture have evolved over centuries. Bridle wires, gold wires, splints, head cap, arch bars, head frames etc have been tried and used. The treatment of maxillofacial fracture took the greatest step ahead in middle of 20 th century with advent of plates and screws [3]. Advantage with these plates and screws are easy to use, allow precise anatomic repositioning, less relapse and in case of mandibular fracture with rigid internal fixation there is no need for maxillomandibular fixation, allowing early return to masticatory function. Stainless steel plates was one of earliest materials used which is resistant to corrosion, but it does corrode and may cause hypersensitivity in patients known to be sensitive to any of its components [3]. Vitallium, titanium evolved later which also showed the corrosion product in distant organs like lungs, liver etc [4]. They also produced star burst or streak artifacts on standard CT scan [5]. To overcome these problems search for better alternative was ignited by the pioneering work by Kulkarni R.K. et al [6]. They studied the synthesis, characterization, tissue reactivity and in vivo degradation of polylactic acid and found no inflammatory reaction to tissue implant. The material was slow degrading and eliminated possibly by carbon dioxide through the 2012. Al Ameen Charitable Fund Trust, Bangalore 373

respiration. This study spurned the interest in using biodegradable materials in the maxillofacial surgical field [6]. In the present study biodegradable plates used for treatment of mandibular symphysis fractures were 4 holed 2.5 mm plates for all cases to ensure uniform results. Only parasymphysis fracture were treated and fractures at other sites of the body of mandible were not treated due to fact that interfragmentory contacts plays an important role during the post-operative stability [7] and hence these fractures were a contraindication for resorbable plates. The undisplaced favorable fractures at the parasymphysis region were plated with resorbable 2.5mm plates and screws. Healing was uneventful in all cases throughout the follow up period of 1 year, in only one case swelling around plate after 6 months was noted which was relieved by antibiotics and antiinflammatory drugs. Swelling may be explained by a combination of factors such as disintegration of PLLA into small particles on increased osmotic pressure caused by these fragments and low mechanical resistance against pressure of subcutaneous tissue compared with bone which leads to noticeable swelling [8]. In the present study, screws breakage and distortion of screw head was noted, similar to findings noted by many authors [9]. When screw breakage occurred there was no need to relocate the plates to second position, as is the case with broken metal screw, instead holes are drilled through the broken screw itself [9]. Bahr W [10] showed by light microscopy that highest mechanical stress was at transition from screw head to screw shaft, there by making it weaker part of screw. Tendency to tighten a A little more to ensure stable fixation may place these screws closer to failure range and in advertent application of excessive torque can lead to shearing off of the screw head [11]. These however occurred in our initial cases probably due to the complexity of handling the material and initial learning curve required as material is highly technique sensitive [12]. No such complications occurred during later cases because the material is highly technique sensitive and with practice placement of plates and screws became easier and quicker reducing the operating time. As these plates are not radiopaque the disappearance of the plates cannot be verified radio-graphically, hence disappearance of bur holes and assessment of degradation by ultrasonography may be taken as an indication of total degradation of plates. It is observed from the present study that bio-resorbable system proved efficient and ideal in treating the maxillofacial fractures. Conclusion With the advent of biodegradable plating system it is hoped that one day it will eventually replace conventional metal plates and screws. Hence we would say that these materials are satisfactory in treatment of maxillofacial fractures offering better advantage, however proper case selection is essential criteria to make these plates successful. Once the cost factor of bioresorbable plating system is taken care these will become useful over the metal plating system. Ultrasonographic aid has proved an essential diagnostic aid in assessing the biodegradation process of plates and screws in mandibular fracture over a period of 1 year in the present study. References 1. Kallela I, Laine P, Suuronen R, Ranta P, Iizuka T, Lindqvist C Osteotomy site healing following mandibular sagittal split osteotomy and rigid fixation with polylactide biodegradable screws. Int. J. Oral Maxillofac. Surg. 1999; 28: 166-70. 2. Cutright DE, Hunsuck EE, Beasley JD Fracture reduction using a biodegradable material, polylactic acid. J. Oral Surg. 1971; 2: 393-7 3. Haug R.H. Retention of asymptomatic bone plates used for orthognathic surgery and facial fractures. J. Oral Maxillofac. Surg. 1996; 54: 611-7. 4. Bos RRM, Boering G, Rozema FR, Leenslag JW: Resorbable poly (L-lactide) plates and screws for fixation of the zygomatic fractures. J. Oral Maxillofac. Surg, 1987; 15: 751-3. 5. Harada K, Enomoto S. Stability after surgical correction of mandibular prognathism using the sagittal split ramus osteotomy andfixationwith poly-l-lactic acid (PLLA) screws. J. Oral Maxillofac Surg. 1997; 55:464-8. 6. Kulkarni R.K, Pani K.C, Neumann C, Leonard F: Polylactic acid for surgical implants. Arch. Surg. 1966; 93: 839-43. 7. Tams J, Otten B, Loon JVP, Bos R.R: A computer study of fracture mobility and strain on biodegradeable plates used for fixation of mandibular 2012. Al Ameen Charitable Fund Trust, Bangalore 374

fractures. J. Oral. Maxillofac. Surg. 1999;57:973-81 8. Kallela I, Tulamo RM, Hietanen J, Pohjonen T, Suuronen R, Lindqvist C: Fixation of mandibular body osteotomies using biodegradable amorphous selfreinforced (70L: 30DL) polylactide or metal lag screws : An experimental study in sheep. J Craniofac Surg 1999; 27: 124-133. 9. Haers P.E., Sailer H.F: Biodegradable self-reinforced poly-l/dl-lactide plates and screws in bimaxillary orthognathic surgery: Short term skeletal stability and material related failures. J. Cranio-Maxillofac. Surg. 1998; 26: 363-72. 10. Bahr W, Stricker A, Gutwald R, Wellens E: Biodegradable Osteosynthesis material for stabilization of midfacial fractures : Experimental investigation in sheep. J. Cranio-Maxillofac. Surg; 1999; 27; 51-7. 11. Shetty V, Caputo AA, Kelso I: Torsion -axial force characteristics of SR-PLLA screws. J. Cranio- Maxillofac Surg 1997; 25: 19-23. 12. Mc Manners J, Moos KF, EI-Attar A: The use of biodegradable fixation in sagittal split and sub sigmoid osteotomy of the mandible : A preliminary report. Br J Oral Maxillofac. Surg. 1997; 35: 401-5. *All correspondences to: Dr. Sulabha. A.N MDS, Professor, Department of Oral Medicine and Radiology, Al-Ameen Dental College and Hospital, Athani Road, Bijapur-586108 Karnataka, India. Email: sulabha595@rediffmail.com 2012. Al Ameen Charitable Fund Trust, Bangalore 375