PPR Original Paper Evaluation of Selective Caries Removal by a Fluorescence Feedback-Controlled Er:YAG La Key Words OOF ser in vitro Abstract Aim:

Similar documents
Diagnodent and the caveats of caries diagnosis by laser fluorescence

Performance of a laser fluorescence device in detecting oclussal caries in vitro

Near-UV light detection

Preprint. Reference. Caries diagnosis using light fluorescence devices: VistaProof and DIAGNOdent. BETRISEY, Emilie, et al.

Assessing Caries Removal by Undergraduate Dental Students Using Quantitative Light- Induced Fluorescence

Performance of Laser Fluorescence for Residual Caries Detection in Primary Teeth

Dental caries are bacterial induced necrosis of tooth structure

DIAGNOdent Measurements and Correlation with the Depth and Volume of Minimally Invasive Cavity Preparations

Evaluation of Dentin Root Canal Permeability After Instrumentation and Er:YAG Laser Application

Correlation between Laser Fluorescence Readings and Volume of Tooth Preparation in Incipient Occlusal Caries In Vitrojerd_

Scanning Is Believing

Original Paper. D.F. Côrtes a K.R. Ekstrand b A.R. Elias-Boneta c, R.P. Ellwood d

71 Photothermal Radiometry and Modulated Luminescence: Applications for Dental Caries Detection

Collaborators. Dental caries. Fluorescence and photochemical reactions: Lessons from teeth and tissues. 54,000+ patient appointments per year

MinimalInvasiveTechniquesinCariesDetectionDiagnosisandMangagementAClinicalStudy

Emphasis has been placed on the diagnosis of occlusal

CLINICAL EVALUATION OF CHEMO-MECHANICAL CARIES REMOVAL USING CARIE-CARE SYSTEM AMONG SCHOOL CHILDREN

Er:YAG and adhesion in conservative dentistry : clinical overview

The Effect of Distance and Tooth Structure on Laser Fluorescence Caries Detection

Early lesion detection at 6-7 years and years schoolchildren from Bucharest, a prediction factor of decay evolution

Detection of intraoral lesions using a fluorescence camera

Endodontics Cracked Tooth: How to manage it in daily practice

EMDOLA Education Program: First Year Details. History of lasers: Optics data : The quantum nature of the light:

Investigation of Dental Caries Using Laser and Light-Induced Autofluorescence Methods

Direct composite restorations for large posterior cavities extended range of applications for high-performance materials

New horizons for Er:YAG lasers: QSP mode advantages in the Lightwalker AT

Diagnostic Values of Laser Fluorescence Device Compared to Other Techniques in Occlusal Caries Detection

KaVo DIAGNOdent. Laser Fluorescence Caries Detection. Ever Play Hide and Seek With Caries?

Up to date literature at your disposal to discover the benefits of laser dentistry

Diagnosis of Pit and Fissure Caries Using Frequency-Domain Infrared Photothermal Radiometry and Modulated Laser Luminescence

Chemomechanical Caries Removal for Children

Comparison of two different methods of detecting residual caries

Title remineralization therapy. Issue Date Australian Dental Associatio

Caries prevention is critical for children, especially. Quantitative Assessment of Enamel Hypomineralization. Permanent Molars of Children in China

Effects of Dental Probing on Occlusal Surfaces A Scanning Electron Microscopy Evaluation

Bangladesh Journal of Medical Science Vol. 17 No. 02 April 18

Chapter 5. Investigation of in vitro Dental Erosion by Optical Techniques

DENTAL CLINICS OF NORTH AMERICA. Emmiam. Incipient and Hidden Caries. GUEST EDITOR Daniel W. Boston, DMD. October 2005 Volume49 Number4

The Effect of Mineralizing Fluorine Varnish on the Progression of Initial Caries of Enamel in Temporary Dentition by Laser Fluorescence

Micro-CT evaluation of cavities prepared with with different Er:YAG handpieces

Use of the ICDAS system and two fluorescence-based intraoral devices for examination of occlusal surfaces

Department of Oral Surgery, Heinrich Heine University, D Düsseldorf, Germany.

Dental Depth Profilometric Diagnosis of Pit & Fissure Caries Using Frequency-Domain Infrared Photothermal Radiometry and Modulated Laser Luminescence

A Comparison of Methods for the Detection of Smooth Surface Caries

MDJ Evaluation the effect of eugenol containing temporary Vol.:9 No.:2 2012

Morphological changes in hard dental tissue prepared using the Er:YAG laser

Anisotropy of Tensile Strengths of Bovine Dentin Regarding Dentinal Tubule Orientation and Location

Dental Depth Profilometric Diagnosis of Pit & Fissure Caries using Frequency-Domain Infrared Photothermal Radiometry and Modulated Laser Luminescence

Comparison of White MTA And Grey MTA in the Apical Sealing Ability of Lased And Unlased Root Canal Walls - A Pilot Study

Chapter 15 Detection of Early Caries by Laser-Induced Breakdown Spectroscopy

powered by technology easy laser guide

Current Concepts in Caries Management Diagnostic, Treatment and Ethical/Medico-Legal Considerations. Radiographic Caries Diagnosis

Medical sciences (2018) 1 16

Photoluminescence spectra of sound tooth and those of different carious stages

Application of two fluorescence methods for detection and quantification of smooth surface carious lesions. Abdulaziz Saad Aljehani

A NOVEL APPROACH FOR TREATING FISSURE CARIES. The problem of hidden caries. Current diagnostic methods

Active Care - Shadeguides How to choose the right Laser

The Histology of Dentin

Relationship between Colors of Carious Dentin and Laser Fluorescence Evaluations in Caries Diagnosis

COVER FEATURE SYNOPSIS

Preclinical Dentistry. I. Dental Caries Non carious lesions: trauma, erosion. abrasion, wedge shaped defects. Lenka Roubalíková

In Vitro Evaluation of the Spectra Early Caries Detection System

Practice Impact Questionnaire

Recovery percentage of remineralization according to severity of early caries

LASERS FOR DENTAL APPLICATIONS.

Efficacy of Chemomechanical Caries Removal System as Compared to Conventional Rotary Method of Caries Removal - An In Vitro Comparative Study

In vivo study of different methods for diagnosing pit and fissure caries

Efficiency of the Polymer Bur SmartPrep Compared with Conventional Tungsten Carbide Bud Bur in Dentin Caries Excavation

Research Article Nd:YAG Lasers Treating of Carious Lesion and Root Canal In Vitro

Update in Caries Diagnosis

An in vitro experiment in the early diagnosis of caries using four diagnostic methods

Restorative Dentistry and it s related to Pulp health. Dr.Ahmed Al-Jobory

stabilisation and surface protection

VistaCam ix HD for diagnostics support in HD quality

Influence of Water Absorption Shift on Ablation Speed of Er:YAG and Er,Cr:YSGG Dental Lasers

Diagnosis versus Detection of Caries

Impact of Photodynamic Therapy Applied by FotoSan on Periodontal Tissues Clinical Parameters

Removal of Human Gingival Melanin Pigmentation by Er:YAG vs Nd:YAG Laser: A Case Report

Periodontal Regeneration

Lec. 3-4 Dr. Saif Alarab Clinical Technique for Class I Amalgam Restorations The outline form

Clinical Evaluation of Polyamide Polymer Burs for Selective Carious Dentin Removal

SOLASE DENTAL DIODE LASER

QSP Mode Characteristics of 3rd Generation ASP Powered Er:YAG Dental Lasers

THERMAL CHANGES IN THE HARD DENTAL TISSUE AT DIODE LASER ROOT CANAL TREATMENT

Measurement of surface hardness of primary carious lesions in extracted human enamel Measurement of Knoop hardness using Cariotester

FACT SHEET: ABOUT DENTAL CARIES

Examination and Treatment Protocols for Dental Caries and Inflammatory Periodontal Disease

Temperature Measurements During Dental Cutting Using an Internally Cooled Diamond Dental Bur

LASERS IN PERIODONTAL THERAPY A REVIEW

NON-IONIZING DIAGNOSTIC PROCEDURES

T he survival of an implant involves

Air-Abrasive Technology for Caries Diagnosis and Fissure Sealing. A Clinical Study

Review of possible predictors for pain perception with class 1 5 cavity preparations using Er,Cr:YSGG laser: a retrospective clinical in vivo study

Gorduysus MO et al. Operating Microscope improves ability to locate and negotiate second canal

ECC II Caries Disease Status. Drs Francisco Ramos-Gomez, Man Wai Ng and Jessica Lee

Fuji II LC. A Perfect Choice

Selected Laser Bibliography and Literature Review Bold type incidates highly recommended reading.

The influence of erbium:yttrium aluminum garnet laser ablation with variable pulse width on morphology and microleakage of composite restorations

Orange/Red Fluorescence of Active Caries by Retrospective Quantitative Light-Induced Fluorescence Image Analysis

Transcription:

Original Paper Caries Res 372 DOI: 10.1159/0000XXXXX Evaluation of Selective Caries Removal by a Fluorescence Feedback-Controlled Er:YAG Laser in vitro J. Eberhard a A.K. Eisenbeiss a A. Braun c J. Hedderich b S. Jepsen a Department of Operative Dentistry and Periodontology and b Department of Medical Statistics, University Hospital Schleswig-Holstein, Kiel and c Department of Periodontology, Operative and Preventive Dentistry, University Hospital Bonn, Bonn, Germany c Received: September 29, 2004 Accepted after revision: February 17, 2005 Key Words Dental caries Fluorescence Laser Treatment Abstract Aim: To establish a fluorescence threshold level that could guide a therapeutic Er:YAG laser through a caries lesion to determine a therapeutic endpoint of caries removal. Materials and Methods: A total of 65 extracted human teeth, 35 with dentine caries and 30 healthy, were used for this study. An Er:YAG laser system that emitted at a wavelength of 2.94 m was used. The laser was equipped with a laser fluorescence feedback system, excitation wavelength 655 nm, to control the irradiation by the Er:YAG laser. The evaluated threshold levels of the fluorescence feedback system were 3, 7, 8, 10, 12, 15 and 20. After treatment the teeth were prepared for histological staining according to the method of Brown and Brenn for the identification of bacteria. The specimens were subjected to a quantitative evaluation of residual bacteria on the treated dentine surface. In addition, the internal fluorescence of dentine and potential fluorescence changes of dentine after laser irradiation were evaluated. Results: About 80% of the irradiated dentine surface showed residual bacteria with threshold levels of 20, 15, 12, and 10. Residual bacteria were not found with threshold levels of 7 and 3. The study revealed a significant increase in dentine fluorescence after laser irradiation. Conclusion: The results of the present in vitro study indicate that a fluorescence threshold level of 7 or 8 units can guide an Er:YAG laser to a complete removal of carious dentine. Copyright 2005 S. Karger AG, Basel By the time a caries process can be detected the lesion is no longer incipient [Gwinnett, 1971] and is generally destined to be restored because of the irreversible nature of the lesion [Angmar-Månsson and ten Bosch, 1987]. The most common procedures for removing infected dental hard tissues are by excavators and burs [Banerjee et al., 2000]. When removing demineralized dentine it is not always easy to know at what point excavation is completed because there is an apparent lack of objective clinical markers for the differentiation between infected and healthy dentine. The clinician tends to rely on the consistency of the tissue, but no rigorous correlation between the consistency of the dentine and the area of infection could be established and changes in hardness and colour are continuous and not abrupt. Therefore, the operative treatment of carious lesions by rotary instruments depends to a significant degree upon the clinical skills of the operator and has often resulted in considerable removal of healthy tooth structure [Banerjee et al., 2000]. Conse- Fax +41 61 306 12 34 E-Mail karger@karger.ch www.karger.com 2005 S. Karger AG, Basel 0008 6568/05/0000 0000$22.00/0 Accessible online at: www.karger.com/cre Jörg Eberhard, DDS, PhD Department of Operative Dentistry and Periodontology University Hospital Schleswig-Holstein, Arnold-Heller-Stasse 16 DE 24105 Kiel (Germany) Tel. +49 (431) 597 2815, Fax +49 (431) 597 2815, E-Mail eberhard@konspar.uni-kiel.de CRE372.indd 1 27.05.2005 10:46:23

quently, a clinical method for the distinction between the outer infected dentine and the inner non-infected dentine is required for the rational treatment of dental caries with minimal destruction of healthy tissues. Several approaches for the selective removal of infected dentine have been introduced during the last decades including the use of caries detector dyes and the chemomechanical caries removal technique. The staining of different carious layers was introduced in 1975 by Ogushi and Fusayama [1975]. However the susceptibility to dye staining by acid red appears to be a feature of reduced mineral content rather than being specific for a carious lesion. Sound circumpulpal dentine and the dentinoenamel junction could also be stained, which may result in the unnecessary removal of sound dentine [Kidd et al., 1993; Yip et al., 1994]. The chemomechanical caries removal approach is basically a gel-assisted hand excavation that is also aimed to determine the endpoint of caries excavation. Chemomechanical caries removal may be associated with a risk of leaving caries in the dentinoenamel junction [Cederlund et al., 1999] and is much more timeconsuming than conventional excavation [Tavares et al., 1988], even though other study groups reported successful caries removal with this system [Ericson et al., 1999]. There has been growing interest in using lasers as diagnostic devices that capitalize on measurements that discriminate between benign and malignant cells [Bohorfoush, 2000]. These methods are based on laser-induced fluorescence that is used for a variety of applications like electrophoresis [Paez and Hernandez, 2001] or photodynamic therapy [Sternberg and Dolphin, 1993]. Fluorescence is a phenomenon by which the wavelength of the emitted light is changed into a longer wavelength upon absorption and subsequent re-emission of light. The fluorescence of dental hard tissues has been known for a very long time and more recently laser light was used to induce fluorescence of enamel in a sensitive, non-destructive diagnostic method for the detection of enamel demineralization and dental caries [Bjelkhagen et al., 1982; Sundström et al., 1985; Lussi et al., 2004]. Laser fluorescence was introduced to aid detection of occlusal caries as an adjunct to visual inspection and radiographic examination [Hibst and Gall, 1998]. Red laser diode light is directed to the tooth surface by a specially designed probe tip, and the fluorescent signal is filtered from the incident light and fed back to the detector through the same device. The excitation wavelength of 655 nm (red light) induces a fluorescence signal that has been assigned to a protoporphyrin, which is present as a bacterial breakdown product [König et al., 1998]. The use of laser-induced fluorescence to control a device that is capable of removing dental hard tissues would be a very promising approach for the selective removal of carious dentine. It has been technically realized by the combination of an Er:YAG laser and a modification of laser fluorescence in one dental instrument. Within this system the removal of dental hard tissues by the Er:YAG laser is controlled by the fluorescence signal from the tooth surface induced by the red-infrared diagnostic laser. However, at present there are no data available on the feasibility of this system for selective caries removal. Therefore, it was the aim of this in vitro study to establish a fluorescence threshold level that could guide the therapeutic laser through a caries lesion until no bacteria were detectable by histological staining and hence a therapeutic endpoint of caries removal was reached. Moreover, for the safe use of this system additional information about the internal fluorescence of dentine and on changes of the dentine fluorescence induced by Er:YAG laser irradiation were gathered. Materials and Methods Specimens Several private dental offices provided a total of 65 extracted human teeth, 35 with dentine caries and 30 healthy, that were used for this study. In each office, the teeth were extracted for periodontal, orthodontic or prosthodontic reasons and were obtained from patients who consented to their use for research. The teeth were stored immediately after extraction in buffered saline at 8 C until further processing. Laser Device An Er:YAG laser system (Key III Laser: Kavo, Biberach, Germany) that emitted at a wavelength of 2.94 m with a spot size of 0.63 mm was used. The output settings were 250 mj/pulse and the pulse repetition rate was 4 pulses/s. These parameters were chosen on the basis of preliminary experiments. Irradiation of a focused beam was performed for the present experiments with the non-contact handpiece 2060 (Kavo, Biberach, Germany). The irradiated area was continuously cooled by a water spray system (1 ml/min). The laser was equipped with a laser fluorescence feedback system ( fig. 1 ). The emitted light with a wavelength of 655 nm (red light) is transported through a fibre bundle to the tip of the handpiece and the same tip, but different fibres, samples the fluorescent light. The laser-induced fluorescence of the dentine is measured and used to control the therapeutic irradiation by turning on the Er: YAG laser if the fluorescence value is above a preselected threshold level. If the dentine fluorescence is below this value the Er:YAG laser does not emit. For the present study the evaluated threshold levels of the fluorescence feedback system were 3, 7, 8, 10, 12, 15 and 20. 2 Caries Res 372 Eberhard /Eisenbeiss/Braun/Hedderich/ Jepsen CRE372.indd 2 27.05.2005 10:47:32

Fig. 1. Schematic illustration showing the construction and light guidance of the fluorescence-assisted Er:YAG laser. (1) The diagnostic laser with a wavelength of 655 nm is transported through a fibre bundle to the tip of the handpiece. (2) The tooth substance emits a fluorescence signal that is collected by separate fibres and transported to an internal analysis unit, which calculates the intensity of the fluorescence light in a range from 0 to 100 fluorescence values. A fluorescence signal smaller than a pre-selected threshold value activates the diagnostic laser. A fluorescence signal greater than a pre-selected threshold value activates the therapeutic Er:YAG laser. (3) The Er:YAG laser light is transported through the handpiece and ablates the tooth substance. 3 1 2 Diagnostic laser (655 nm) Red fluorescence > Threshold level Er:YAG laser 2.94 µm Threshold level Fig. 2. Brown and Brenn staining shows the bacterial deposits within the untreated carious dentine ( A ) and after Er:YAG laser treatment with threshold levels of 15 ( B ), 12 ( C ) and 7 ( D ). The insert ( E ) shows the residual dentine after conventional excavation with a bur. A Original magnification! 40. B E Original magnification! 20. Fluorescence Threshold Level For all experimental procedures the enamel was removed by high-speed burs and water cooling until access to the carious lesion was achieved. On the surface of the carious lesion small incisions were cut with a sharp scalpel blade to divide the lesion into three areas that were treated as follows: (A) no treatment, (B) caries removal with a bur at a speed of 700 rpm without water cooling and (C) laser irradiation. The specimens were assigned randomly to the different groups. Before the experiments the operator received a full training in caries removal using the laser. After calibration of the fluorescence feedback system following the instructions of the manufacturer the handpiece was manually adjusted perpendicular to the treated surface. The handpiece was used in the non-contact irradiation mode with a distance from the tip to the cavity floor of approximately 12 15 mm. The pilot laser beam was used to adjust the correct distance and as caries removal progressed and the distance of the treated cavity floor to the tip of the handpiece changed, irradiation Caries Treatment by Fluorescence-Guided Er:YAG Laser Caries Res 372 3 CRE372.indd 3 27.05.2005 10:47:32

was paused and the distance was readjusted. The laser treatment was terminated if the fluorescence feedback system did not indicate any reflective fluorescence from the dentine above the pre-selected threshold level. No caries disclosing agent or dental probe was used to explore the laser-treated dentine surface after laser irradiation. For every pre-selected threshold level 5 specimens were treated. Conventional bur treatment was performed by an experienced dentist in a dry field by means of steel burs of the appropriate size mounted on a micromotor at low speed. The consistency of the tissue was examined with a dental explorer to confirm the completeness of caries removal. Sample Preparation After treatment the teeth were cut through the incisions along the tooth axis in three specimens with a cutting saw (WoCo Apparatebau, Clausthal-Zellerfeld, Germany). The specimens were fixed in phosphate-buffered formalin for 24 h and then washed in Sörensen phosphate-buffered saline for another 24 h. After dehydration by alcohol the specimens were embedded in methacrylate (Sigma-Aldrich, Dreieich, Germany). The polymerized specimens were placed onto microscopic slides and ground to approximately 30- to 60- m-thin slices. Two slices were fabricated from each specimen (n = 240). The slices were stained by the method of Brown and Brenn [1931] for the identification of gram-positive (blue) and gram-negative (red) bacteria. Quantitative Evaluation The samples were investigated under a microscope (Axiophot 2, Carl Zeiss, Jena, Germany) at a total magnification of! 100.8 (Lens Plan-Neofluar! 63 and ocular E-P1! 10; Zeiss). A test grid was mounted on the focal plane of the eyepiece of the microscope and consisted of a square frame of a definitive size enclosing an area of 4,681 m 2. Five test grids were randomly located on the surface of treated dentine and the number of test squares positive for bacteria within the dentinal tubules was expressed as percentage of the total number of squares covering the treated dentine surface. For each threshold level 5 teeth were used and two individual specimens were investigated quantitatively. Internal Fluorescence of the Dentine Twenty non-carious third molars that had been removed during orthodontic treatments were selected for this experiment. The teeth were divided into halves along the long axis by a cutting saw with water cooling. In 10 teeth, beginning from the occlusal surface to the roof of the pulp chamber the fluorescence of the tooth hard substance was measured with the laser handpiece 2060 (Key III Laser, Kavo) and with the DIAGNOdent device (Kavo). After each measurement about 0.5 mm of dentine was removed with a low-speed bur until the pulp chamber became exposed. A micrometer measuring system under a stereomicroscope at! 16 magnification was used to measure the distance between the prepared tooth surface and the pulp chamber. In a second group (n = 10) this procedure was repeated to measure the internal fluorescence of the dentine in the opposite direction from the pulp chamber to the enamel-dentine border. Fluorescence of Irradiated Dentine Ten non-carious third molars were selected and cut along the tooth long axis as described to determine the fluorescence changes in dentine induced by therapeutic laser irradiation. The dentine was irradiated with the therapeutic Er:YAG laser without the fluorescence-feedback system under a stereomicroscope at! 16 magnification until approximately 0.5 mm of dentine had been removed. The fluorescence of the resulting dentine surface was recorded by both the therapeutic laser system (Key III laser handpiece 2060) and by the diagnostic device (DIAGNOdent) and subsequently 0.5 mm of dentine was removed with a rotary bur. Again, the fluorescence values were recorded and the dentine was irradiated by the Er:YAG laser until another 0.5 mm of dentine was removed. This procedure was continued until the pulp chamber became exposed. Statistical Analysis For each experimental group the fluorescence values were described by means 8 standard deviations (SD). Obvious extreme values or outliers were not observed. Nevertheless, normal distribution was not assumed in the data for statistical testing, because for 10 teeth in each experimental group any test for normal distribution has only small power. Differences between reading points at different steps of the experimental procedure were evaluated with Friedman analysis of variances by ranks and multiple comparisons. Differences between the fluorescence readings of the DIAGNOdent and the laser and between different treatment regimes were compared at each step by Wilcoxon matched-pairs signed-rank test. All calculations were performed with the statistical program SPSS 11. Effects were regarded as statistically significant for p! 0.05. Results Fluorescent Threshold Level The dentine surface of an untreated carious lesion showed that 100% of the dentinal tubules located in the carious lesion contained bacteria that completely filled the dentine tubules ( fig. 2 A). Following treatment of the carious lesions with a rotary bur and confirmation of caries removal with a dental explorer no bacteria were found in the residual dentine of the cavity floor ( fig. 2 E). The results for the histological evaluation following caries removal by Er:YAG laser are presented in figure 2 A D. Employing the Er:YAG laser with fluorescence threshold levels of 20, 15, 12 and 10, respectively, revealed only a minor reduction of residual bacteria within the dentinal tubules from 94.0 to 88.0% ( table 1 ). In contrast, the fluorescence threshold level of 8 resulted in a significant decrease in residual bacteria within dentinal tubules of the cavity floor to a mean percentage of 6.7%. Laser ablation of carious dentine with the guidance of the fluorescence threshold levels of 7 and 3 resulted in no residual bacteria within the dentine tubules located at the cavity floor ( table 1 ). 4 Caries Res 372 Eberhard /Eisenbeiss/Braun/Hedderich/ Jepsen CRE372.indd 4 27.05.2005 10:47:39

14 12 10 14 12 10 Fluorescence 8 6 4 Fluorescence 8 6 4 2 2 0 0 2 0 1.0 2.0 3.0 Distance to pulp (mm) 4.0 5.0 6.0 2 0.5 0.5 1.5 2.5 Distance to dentinoenamel junction (mm) 3.5 Fig. 3. Variation in the fluorescence readings of the laser handpiece 2060 (circles) and for the DIAGNOdent device (squares) in the direction towards the roof of the pulp chamber (means 8 SD). The fluorescence readings of the DIAGNOdent increase towards the pulp, but without any statistically significance. The experiment was reproduced 10 times on different samples. Fig. 4. Variation in the fluorescence readings of the laser handpiece 2060 (circles) and for the DIAGNOdent device (squares) from the roof of the pulp chamber to the dentinoenamel junction (mean 8 SD). The experiment was reproduced 10 times on different tooth samples. Table 1. Means and SD of the residual amounts of bacteria (%) estimated by a quantitative approach on the laser-treated dentine surface with different threshold levels of the fluorescence feedback system n Residual bacteria, % of tubules mean SD Control Untreated caries 5 100 0.0 Bur treatment 5 0.0 0.0 Laser threshold value 20 5 94.0 13.4 15 5 98.0 4.5 12 5 90.0 12.3 10 5 93.3 11.6 8 5 6.7 11.6 7 5 0.0 0.0 3 5 0.0 0.0 For control purposes untreated carious lesions and carious lesions treated by a bur were used. For each threshold level 5 teeth were investigated and the quantitative evaluation was performed on two separate specimens. PROOF Fluorescence of Dentine The measurements of the dentine fluorescence by the laser handpiece and the DIAGNOdent device from the enamel-dentine surface to the roof of the pulp chamber are illustrated in figure 3. The mean fluorescence values of healthy dentine measured by the DIAGNOdent device were statistically significantly higher than those measured with the laser handpiece for every reading point (p = 0.005). The statistical analysis demonstrated no significant differences between the mean fluorescence values for different measuring points from the dentinoenamel junction to the roof of the pulp chamber for the DIAGNOdent device or for the laser handpiece, even though the values had a tendency to increase 2.0 mm away from the roof of the pulp chamber. In consequence, a mean fluorescence recording for dentine of 6.2 8 2.4 (mean 8 SD) was measured with the DIAGNOdent device and of 1.1 8 0.8 with the laser handpiece. In a similar fashion fluorescence values of healthy dentine from the roof of the pulp chamber to the dentinoenamel junction are presented in figure 4. Again, the mean fluorescence values measured with the DIAGNO- Caries Treatment by Fluorescence-Guided Er:YAG Laser Caries Res 372 5 CRE372.indd 5 27.05.2005 10:47:39

40 30 8 6 Fluorescence 20 Fluorescence 4 10 2 0 0.5 1.5 1.5 2.5 2.5 3.5 3.5 4.5 Distance to pulp (mm) 0 0.5 1.5 1.5 2.5 2.5 3.5 3.5 4.5 Distance to pulp (mm) Fig. 5. Variation in the fluorescence readings of the DIAGNOdent device before (squares) and after (filled squares) laser irradiation at different intervals of the distance towards the roof of the pulp chamber (mean 8 SD). The experiment was reproduced 10 times on different samples. Fig. 6. Variation in the fluorescence readings of the dentine surface after bur treatment (circles) and after laser irradiation (filled circles) at different intervals of the distance towards the roof of the pulp chamber (mean 8 SD). For the experiment the readings were performed on the same samples used for the DIAGNOdent readings. dent device were statistically significantly higher than those obtained with the laser handpiece for every reading point (p = 0.005). There were no statistically significant differences between the mean fluorescence values for individual measuring points from the roof of the pulp chamber to the dentinoenamel junction for both fluorescence devices. Thus, by scanning the dentine from the roof of the pulp chamber to the dentinoenamel junction opposite to the direction of the first series of measurements a mean fluorescence recording for dentine of 5.3 8 2.8 was measured with the DIAGNOdent device and of 1.3 8 0.9 with the laser handpiece. Fluorescence of Laser-Irradiated Dentine The Er:YAG laser irradiation significantly increased the fluorescence signal of sound dentine measured by DI- AGNOdent ( fig. 5 ) or the laser handpiece ( fig. 6 ) compared to the dentine treated with a bur, irrespective of the reading point within the dentine (p = 0.005). The mean fluorescence of dentine increased from 5.4 8 2.5 to 18.2 8 11.4 after laser irradiation measured by the DIAGNOdent device, and from 1.4 8 1.1 to 3.3 8 1.9 measured with the laser handpiece. PROOF Discussion Present diagnostic methods used to indicate the endpoint of caries removal in a clinical situation are quite subjective and may thus lead to either under- or overinstrumentation. Ideally, a diagnostic tool should indicate the presence or absence of bacteria because of the infectious nature of the disease. A defined endpoint of caries removal would therefore coincide with the complete removal of all bacteria-infected dentine. The results of the present in vitro study could demonstrate the capacity of selective caries removal for an Er:YAG laser that is controlled by the fluorescence signal from bacterial breakdown products induced by a red-infrared diagnostic laser. Hibst and Keller [1989] first demonstrated the effective ablation of dental hard tissues by means of the Er: YAG laser. The application of the Er:YAG laser has been used for caries treatment in vitro [Aoki et al., 1998; Armengol et al., 1999] and in clinical situations as well [Keller and Hibst, 1997; Keller et al., 1998]. No differences in the effectiveness of dentine removal by an Er: YAG laser compared to a conventional drill have been 6 Caries Res 372 Eberhard /Eisenbeiss/Braun/Hedderich/ Jepsen CRE372.indd 6 27.05.2005 10:47:40

reported [Hibst and Keller, 1989; Keller and Hibst, 1989; Shigetani et al., 2002]. In general, it is accepted that under adequate water spray and with a careful irradiation technique, cavities without any sign of thermal damage to the surrounding tissues as well as to the dental pulp could be produced with the Er:YAG laser [Hossain et al., 1999; Yamada et al., 2001]. Animal histological studies also showed that the pulp response to the Er:YAG laser appears to be similar to the response from high-speed handpiece application [Sonntag et al., 1996]. In an in situ study no pathological changes were observed 7 days after Er: YAG laser treatment by light transmission electron microscopy and 3 months postoperatively the apposition of tertiary dentine has been demonstrated [Nair et al., 2003]. The experiments aimed at determining a threshold level for the fluorescence-aided caries removal by an Er: YAG laser demonstrated almost no caries removal with threshold levels between 10 and 20, a marked reduction of residual bacteria below 10% with a threshold level of 8, and no detectable residual bacteria for threshold levels of 7 and smaller. It is noticeable that no linear correlation between the bacterial reduction and the pre-selected threshold level could be observed, but rather an abrupt decrease in a narrow range between 7 and 9 units. Thus, the fluorescence feedback system appears to operate by a true yes or no decision with respect to the detection of even small numbers of bacteria within the dentine. In contrast to other methods like explorers aimed to determine the endpoint of caries removal the induced fluorescence of 655 nm is likely related to bacterial components as proposed by König et al. [1998]. The relation between microoganisms or bacterial products and the fluorescence signal has been confirmed in the present study and in a recently published study by Iwami et al. [2003]. In contrast to other fluorescence-aided caries excavation techniques like the FACE method [Lennon et al., 2002; Lennon, 2003], that combines caries detection by fluorescence with caries removal by a rotary instrument, the fluorescence directly regulates the activity of the device used for dentine treatment, which might be an advantage during clinical use. For the safe use of this system, additional information about the internal fluorescence of dentine and on changes of the dentine fluorescence induced by Er:YAG laser irradiation was required. With respect to the determination of a threshold level, substantial variations of the fluorescence in different regions of sound dentin would rule out the possibility of determining a single threshold level or even the use of this system for clinical caries removal. In fact, previous studies showed that the transmission and scattering properties of dentine differ according to the direction of the tubules and this affected the fluorescence measurements [Vaarkamp et al., 1995; Iwami et al., 2003]. Therefore, in the first part of the present study we evaluated the fluorescence characteristics of sound dentine with the laser handpiece and with a laser fluorescence device to investigate the fluorescence readings from the dentinoenamel junction to the roof of the pulp. It could be demonstrated that the fluorescence readings showed only minor variations at different locations of the dentine that were not statistically significantly different. Increased fluorescence values of the dentine approaching the roof of the pulp chamber were also reported by Lussi et al. [2000]. Irrespective of the direction of the readings, towards the pulp or away from the roof of the pulp chamber, no differences in fluorescence signals were observed and it was therefore possible to determine mean fluorescence values for non-carious dentine. Laser fluorescence has been proven as a useful tool for the detection of early lesions on the occlusal surface [Lussi et al., 1999, 2001; Francescut and Lussi, 2003], although the agreement between validated caries and the fluorescence signal is still unsatisfactory when using the device to detect carious dentine under enamel [Heinrich- Weltzien et al., 2003]. However, the carious lesion is not covered by enamel in the current approach and this might improve detection. When comparing the fluorescence readings by the laser handpiece and by laser fluorescence, the latter measurements were about 4 6 times greater, but the two sets closely correlated with each other. This observation was most likely due to different light transmission systems in the laser handpiece and in the DIAG- NOdent device. The light transmission window of the laser handpiece has a larger diameter than that of the cone-shaped tip of the DIAGNOdent and the former picked up light from outside the target surface as well. Therefore, the manufacturer adjusted the sensitivity of the laser handpiece. Another safety issue that had to be addressed before any clinical use was the possible impact on the dentine fluorescence by the Er:YAG laser irradiation itself. Instead of perpendicular measurements of sectioned carious teeth we selected an experimental protocol that closely resembled the clinical direction of caries removal towards the pulp chamber. Interestingly, the results of the present study could demonstrate that the ablation of dentine by the Er:YAG laser significantly increased the fluorescence values of the resulting dentine surface as measured by the laser and the laser fluorescence device. Again, Caries Treatment by Fluorescence-Guided Er:YAG Laser Caries Res 372 7 CRE372.indd 7 27.05.2005 10:47:40

the laser fluorescence readings were greater by a factor of 5 6 than the laser readings. The observed increase of the fluorescence induced by the laser irradiation was by a factor of 2 3. It could be assumed that laser treatment of the dentine was followed by a dehydration of the dentine that could induce the observed increase in fluorescence. In contrast to the present findings in vitro studies demonstrated that dehydration of enamel was accompanied by decreased fluorescence values [Al-Khateeb et al., 2002; Pretty et al., 2004]. Whether structural changes of the dentine after laser ablation, dehydration or any other thermal effects were the origin of the changes in fluorescence values could not be evaluated in the present study; this question should be addressed by future research. The increase in fluorescence values by the Er:YAG laser itself is of potential concern, because sound dentine could emit fluorescence signals exceeding the established threshold level leading to its removal. However, from the present data it could be calculated that 68 and 98% of fluorescence values read by the laser handpiece from irradiated sound dentine were in the range of 1.4 5.2 and 0 7.1, respectively. From these data it could be concluded that a threshold level of 7 or greater will not have any impact on changes in dentinal fluorescence induced by the laser irradiation itself for most of the cases under the present in vitro situation. In conclusion, the results of the present in vitro study suggest that a fluorescence threshold level of 7 or 8 units could guide an Er:YAG laser to a complete removal of carious dentine. Because ablation by this laser is controlled by the induced fluorescence of bacteria or bacterial products this method may be superior to current methods for caries removal where the endpoint of the treatment is determined by subjective means. Thus, on the basis of these promising results future studies are warranted to validate the present findings under in vivo conditions, before fluorescence-controlled selective caries removal by Er:YAG laser can be recommended for clinical use. References Al-Khateeb S, Exterkate RA, de Josselin de Jong E, Angmar-Mansson B, ten Cate JM: Light-induced fluorescence studies on dehydration of incipient enamel lesions. Caries Res 2002; 36: 25 30. Angmar-Månsson B, ten Bosch JJ: Optical methods for the detection and quantification of caries. Adv Dent Res 1987; 1: 14 20. Aoki A, Ishikawa I, Yamada T, Otsuki M, Watanabe H, Tagami J, Ando Y, Yamamoto H: Comparison between Er:YAG laser and conventional technique for root caries treatment in vitro. J Dent Res 1998; 77: 1404 1414. Armengol V, Jean A, Rohanizadeh R, Hamel H: Scanning electron microscopic analysis of diseased and healthy dental hard tissues after Er: YAG laser irradiation: In vitro study. J Endod 1999; 25: 543 546. Banerjee A, Kidd EA, Watson TF: In vitro evaluation of five alternative methods of carious dentine excavation. Caries Res 2000; 34: 144 150. Bjelkhagen H, Sundström F, Angmar-Månsson B, Ryden H: Early detection of enamel caries by the luminescence excited by visible laser light. Swed Dent J 1982; 6: 1 7. Bohorfoush AG: New diagnostic methods for esophageal carcinoma. Recent Results Cancer Res 2000; 155: 55 62. Brown JH, Brenn L: Method for the differential staining of Gram-positive and Gram-negative bacteria in tissue sections. Bull John Hopkins Hosp 1931; 48: 69 73. Cederlund A, Lindskog S, Blomlof J: Efficacy of Carisolv-assisted caries excavation. Int J Periodontics Restorative Dent 1999; 19: 464 469. Ericson D, Zimmerman M, Raber H, Gotrick B, Bornstein R, Thorell J: Clinical evaluation of efficacy and safety of a new method for chemomechanical removal of caries: A multi-centre study. Caries Res 1999; 33: 171 177. Francescut P, Lussi A: Correlation between fissure discoloration, Diagnodent measurements, and caries depth: An in vitro study. Pediatr Dent 2003; 25: 559 564. Gwinnett AJ: A comparison of proximal carious lesions as seen by clinical radiography, contact microradiography, and light microscopy. J Am Dent Assoc 1971; 83: 1078 1080. Heinrich-Weltzien R, Kuhnisch J, Oehme T, Ziehe A, Stosser L, Garcia-Godoy F: Comparison of different DIAGNOdent cut-off limits for in vivo detection of occlusal caries. Oper Dent 2003; 28: 672 680. Hibst R, Gall R: Development of a Diode Laser- Based Fluorescence Caries Detector. Caries Res 1998; 32: 267 317. Hibst R, Keller U: Experimental studies of the application of the Er:YAG laser on dental hard substances. I. Measurement of the ablation rate. Lasers Surg Med 1989; 9: 338 344. Hossain M, Nakamura Y, Yamada Y, Kimura Y, Matsumoto N, Matsumoto K: Effects of Er,Cr: YSGG laser irradiation in human enamel and dentine: Ablation and morphological studies. J Clin Laser Med Surg 1999; 17: 155 159. Iwami Y, Shimizu A, Yamamoto H, Hayashi M, Takeshige F, Ebisu S: In vitro study of caries detection through sound dentine using a laser fluorescence device, DIAGNOdent. Eur J Oral Sci 2003; 111: 7 11. Keller U, Hibst R: Experimental studies of the application of the Er:YAG laser on dental hard substances. II. Light microscopic and SEM investigations. Lasers Surg Med 1989; 9: 345 351. Keller U, Hibst R: Effects of Er:YAG laser in caries treatment: A clinical pilot study. Lasers Surg Med 1997; 20: 32 38. Keller U, Hibst R, Geurtsen W, Schilke R, Heidemann D, Klaiber B, Raab WH: Erbium:YAG laser application in caries therapy: Evaluation of patient perception and acceptance. J Dent 1998; 26: 649 656. Kidd EA, Joyston-Bechal S, Beighton D: The use of a caries detector dye during cavity preparation: A microbiological assessment. Br Dent J 1993; 174: 245 248. König K, Flemming G, Hibst R: Laser-induced autofluorescence spectroscopy of dental caries. Cell Mol Biol (Noisy-le-grand) 1998; 44: 1293 1300. Lennon ÁM: Fluorescence-aided caries excavation (FACE) compared to conventional method. Oper Dent 2003; 28: 341 345. Lennon ÁM, Buchalla W, Switalski L, Stookey GK: Residual caries detection using visible fluorescence. Caries Res 2002; 36: 315 319. 8 Caries Res 372 Eberhard /Eisenbeiss/Braun/Hedderich/ Jepsen CRE372.indd 8 27.05.2005 10:47:41

Lussi A, Francescut P, Achermann F, Reich E, Hotz P, Megert B: The use of the DIAGNOdent during cavity preparation (abstract 56). Caries Res 2000; 34: 308 360. Lussi A, Hibst R, Paulus R: DIAGNOdent: An optical method for caries detection. J Dent Res 2004; 83(special issue C):C80 83. Lussi A, Imwinkelried S, Pitts N, Longbottom C, Reich E: Performance and reproducibility of a laser fluorescence system for detection of occlusal caries in vitro. Caries Res 1999; 33: 261 266. Lussi A, Megert B, Longbottom C, Reich E, Francescut P: Clinical performance of a laser fluorescence device for detection of occlusal caries lesions. Eur J Oral Sci 2001; 109: 14 19. Nair PN, Baltensperger MM, Luder HU, Eyrich GK: Pulpal response to Er:YAG laser drilling of dentine in healthy human third molars. Lasers Surg Med 2003; 32: 203 209. Ogushi K, Fusayama T: Electron microscopic structure of the two layers of carious dentine. J Dent Res 1975; 54: 1019 1026. Paez X, Hernandez L: Biomedical applications of capillary electrophoresis with laser-induced fluorescence detection. Biopharm Drug Dispos 2001; 22: 273 289. Pretty IA, Edgar WM, Higham SM: The effect of dehydration on quantitative light-induced fluorescence analysis of early enamel demineralisation. J Oral Rehabil 2004; 31: 179 184. Shigetani Y, Tate Y, Okamoto A, Iwaku M, Abu- Bakr N: A study of cavity preparation by Er: YAG laser: Effects on the marginal leakage of composite resin restoration. Dent Mater J 2002; 21: 238 249. Sonntag KD, Klitzman B, Burkes EJ, Hoke J, Moshonov J: Pulpal response to cavity preparation with the Er:YAG and Mark III free electron lasers. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 1996; 81: 695 702. Sternberg ED, Dolphin D: Second generation photodynamic agents: A review. J Clin Laser Med Surg 1993; 11: 233 241. Sundström F, Fredriksson K, Montan S, Hafstrom-Bjorkman U, Strom J: Laser-induced fluorescence from sound and carious tooth substance: Spectroscopic studies. Swed Dent J 1985; 9: 71 80. Tavares M, Soparkar PM, DePaola PF: Evaluation of a chemomechanical method of caries removal in root surface lesions. Quintessence Int 1988; 19: 29 32. Vaarkamp J, ten Bosch JJ, Verdonschot EH: Propagation of light through human dental enamel and dentine. Caries Res 1995; 29: 8 13. Yamada Y, Hossain M, Nakamura Y, Suzuki N, Matsumoto K: Comparison between the removal effect of mechanical, Nd:YAG, and Er: YAG laser systems in carious dentine. J Clin Laser Med Surg 2001; 19: 239 243. Yip HK, Stevenson AG, Beeley JA: The specificity of caries detector dyes in cavity preparation. Br Dent J 1994; 176: 417 421. Caries Treatment by Fluorescence-Guided Er:YAG Laser Caries Res 372 9 CRE372.indd 9 27.05.2005 10:47:41

Filename: CRE372 Article-No: 372, Fig.: 6, Tab.: 1 <Issueid>000</Issueid> </S> <F16_Sup>a </F16_Sup> </S> <F16_Sup>a </F16_Sup> <I>A. </I> <S>Braun </S> <F16_Sup>c </F16_Sup> </S> <F16_Sup>b </F16_Sup> <I>S. </I> <S>Jepsen </S> <F16_Sup>c </F16_Sup> <I>J. </I> <S>Eberhard <I>A.K. </I> <S>Eisenbeiss <I>J. </I> <S>Hedderich Abstract Sorry, there is no abstract. Read the first few lines of the text instead! Copyright 2005 S. Karger AG, Basel CRE372.indd 10 27.05.2005 10:47:41