GBR membrane for ideal regeneration. i-gen TM. 2mm. >2.5mm. Lingual Extension. >100 blunt angle

Similar documents
GBR membrane for ideal regeneration

03 Best combination for thin ridge

CASE REPORT MEGAGEN IMPLANT. AnyRidge. CLINICAL CASE REPORT Davide Farronato, DDs, PhD, PD, AP

Case Study. Case # 1 Author: Dr. Suheil Boutros (USA) 2013 Zimmer Dental, Inc. All rights reserved. 6557, Rev. 03/13.

REGENERATION. The future is already here

TruAbutment Digital Solutions

The Use of Alpha-Bio Tec's Narrow NeO Implants with Cone Connection for Restoration of Limited Width Ridges

Case Report. RapidSorb Rapid Resorbable Fixation System. Ridge augmentation in a one-step surgical protocol.

MiNiTM. Easy and Strong Solution for Narrow Ridge. Volume MiNi C4.0

Benefits of CBCT in Implant Planning

Contents HIOSSEN IMPLANT

Rehabilitating a Compromised Site for Restoring Form, Function and Esthetics- A Case Report

Redefining Regeneration

Socket Graft Plus. Case Presentation. Ideal Bone Graft for All Socket Grafting Situations. Case #1

Ridge Split Procedure

The anatomic limitations of the. Implant Installation With Simultaneous Ridge Augmentation. Report of Three Cases Jun-Beom Park, DDS, MSD, PhD*

Prosthetic Options in Implant Dentistry. Hakimeh Siadat, DDS, MSc Associate Professor

Bringing you Geistlich biocompatibility with improved application and handling benefits. Your combination for success

Management of a complex case

Rehabilitation of atrophic partially edentulous mandible using ridge split technique and implant supported removable prosthesis

Vertical and Horizontal Ridge Augmentation of a Severely Resorbed Ridge in the Anterior Maxilla

Tapered Screw-Vent Implant System

Dentium Implant System. New Product

Patient s Presenting Complaint V.C. presented with discomfort and mobility from the crowned maxillary left central incisor tooth. Fig 1.

MANAGEMENT OF ATROPHIC ANTERIOR MAXILLA USING RIDGE SPLIT TECHNIQUE, IMMEDIATE IMPLANTATION AND TEMPORIZATION

CASE REPORT. CBCT-Assisted Treatment of the Failing Long Span Bridge with Staged and Immediate Load Implant Restoration

How something small, can make such a big difference!! Your best choice in overdenture

The solution for the edentulous patients. Prosthetics compatibillity 3i Multi-unit Abutment Regular Abutment (MegaGen)

Socket preservation in the daily practice: A clinical case report

Immediate Implant Placement Along With Guided Bone Regeneration In Mandibular Anterior Region A Case Report.

MINI System CASE REPORT. Name: Dr. Achraf Souayah Na<on: Tunisia

INTRODUCTION. General Information. Important Warning

Replacement of a congenitally missing lateral incisor in the maxillary anterior aesthetic zone using a narrow diameter implant: A case report

DIOnavi. Brochure Ver.2. Product Introduction: DIOnavi. Clinical Case Report

LOCATOR F-Tx FIXED ATTACHMENT SYSTEM

Clinical cases by Dr. Fernando Rojas-Vizcaya. botiss. dental bone & tissue regeneration. biomaterials. strictly biologic

OSSTEM Clinical Cases

Mesial Step Class I or Class III Dependent upon extent of step seen clinically and patient s growth pattern Refer for early evaluation (by 8 years)

Osseointegrated dental implant treatment generally

Principles of Periodontal flap surgery. Dr.maryam khosravi

Immediate Implant Placement:

Immediate implant placement in the Title central incisor region: a case repo. Journal Journal of prosthodontic research,

RPC. Surgical Solutions USA Regenerative Product Catalog

SwissPlant Prosthetic Catalog. SwissPlant

Periapical Radiography

PRE-MILLED ABUTMENTS COMPLETE SOLUTIONS

Dental Implant Treatment Planning and Restorative Considerations

Ridge Augmentation. Selection of Applicable Abstracts and Posters. Using Titanium-Reinforced PTFE Membranes

Consensus Report Tissue augmentation and esthetics (Working Group 3)

Masking Buccal Plate Remodeling in the Esthetic Zone with Connective Tissue Grafts: Concepts and Techniques with Immediate Implants

LOCATOR F-Tx FIXED ATTACHMENT SYSTEM

Alveolar Bone Remodeling and Development after Immediate Orthodontic Root Movement

SwishPlant. SwishPlant System Catalog. 4.8mmD mmD. 4.8mmD mmD. 3.7mmD mmD. 6.5mmD

Thick vs. Thin Gingival Biotypes: A Key Determinant in Treatment Planning for Dental Implants

Surgical Procedure in Guided Tissue Regeneration with the. Inion GTR Biodegradable Membrane System

Vertical and Horizontal Augmentation Using Guided Bone Regeneration. Ph.D. Thesis. Dr. med. dent. et univ. Istvan Urban

hard tissue maxgraft cortico Surgical guide botiss biomaterials innovative efficient atraumatic Prefabricated allogenic bone plate

Head Office & Factory Gangnam Office

NR Line Product Catalog

Cover Page. The handle holds various files of this Leiden University dissertation.

A new approach with an in-situ self-hardening grafting material

Implant Placement in Maxillary Anterior Region Along with Soft and Hard Tissue Grafting- A Case Report.

Alveolar Ridge Augmentation with Titanium Mesh and Particulate Allograft A Case Report

Clinical Perspectives

Dental Implants: A Predictable Solution for Tooth Loss. Reena Talwar, DDS PhD FRCD(C) Oral & Maxillofacial Surgeon Associate Clinical Professor

Flapless, Immediate Implantation & Immediate Loading with Socket Preservation in the Esthetic Area Using the Alpha-Bio Tec's NeO Implants

Evaluation of a Combination Allograft Material Compared to DFDBA in Alveolar Ridge Preservation. Sanju P. Jose

simply simply digital simply crown & bridge simply removable simply fixed simply à la carte

BUILDING A. Achieving total reconstruction in a single operation. 70 OCTOBER 2016 // dentaltown.com

BONE AUGMENTATION AND GRAFTING

Contemporary Implant Dentistry

Surgical Solutions USA Regenerative Product Catalog USA

REGENERATIONTIME. A Case Report by. Ridge Augmentation and Delayed Implant Placement on an Upper Lateral Incisor

Pouch Roll Technique for Implant Soft Tissue Augmentation: A Variation of the Modified Roll Technique

SHELL TECHNIQUE WITH ALLOGENIC CORTICAL STRUTS

Limited bone availability makes implant placement challenging

Oral Rehabilitation with CAMLOG implants after loss of dentition due to an accident

One-year Re-entry Results of Guided Bone Regeneration around Immediately Placed Implants with Immediate or Conventional Loading: A Case Series

contents the smarter case approach reasons to choose simplyintegrated 5 system overview 6 ordering 7 mount-free implants 8-9

The Sandwich Bone Augmentation Technique. Jia-Hui Fu* and Hom-Lay Wang*

Hyun-Jae Cho, Kun-Soo Jang, Ki-Hyun Jeong, Jae-Yun Jeon, Kyung-Gyun Hwang, Chang-Joo Park

Pre op Failed endodontic treatment with sinus involvement.

International Journal of Health Sciences and Research ISSN:

Socket grafting and ridge preservation using Bond Apatite. Cases 1. Surgery Dr. David Baranes D.M.D

immediate implantation and loading with Paltop Osteotomes for bone expansion Case Study

OD Secure chairside pick-up using existing denture

Techniques of local anesthesia in the mandible

Practical Advanced Periodontal Surgery

Advanced Probing Techniques

Surgical Manual. Step By Step Techniques

Years of research and advancement in

LOCATOR R-Tx REMOVABLE ATTACHMENT SYSTEM

Extraction with Immediate Implant Placement and Ridge Preservation in the Posterior

SCD Case Study. The ability of the integrated implant to bear a load must be greater than the anticipated load during function.

GMI FRONTIER implant system. Surgical procedures guide

Utilizing Digital Treatment Planning and Guided Surgery in Conjunction with Narrow Body Implants. by Timothy F. Kosinski, DDS, MAGD

Gingivectomy, excision gingival, each quadrant Gingivoplasty, each quadrant

Periimplant Regeneration Fenestration

Transforming the Implant Industry. Broadest Product Line Highest Quality-Best Value

Transcription:

REGENERATION 02/03 Design Concept GBR membrane for ideal regeneration i-gen TM Description Single A type Small IG1W4509 Single A type Regular IG1W5510 Single A type Wide IG1W6511 Single B type Small IG2W0918 Single B type Regular IG2W1120 Single B type Wide IG2W1323 Single C type Small IG3W0921 Single C type Regular IG3W1125 Single C type Wide IG3W1328 1mm Cuff [AnyRidge] IA1810 i-gen 2mm Cuff [AnyRidge] IA1820 3mm Cuff [AnyRidge] IA1830 1mm Cuff [AnyOne] IA2010 2mm Cuff [AnyOne] IA2020 3mm Cuff [AnyOne] IA2030 1.5mm Cuff [MiNi] IA1415 2mm Cuff [MiNi] IA1420 3mm Cuff [MiNi] IA1430 Flat Healing Abutment H=2.5mm FHA402 Flat Healing Abutment H=3.5mm FHA403 i-gen Cover Screw ICS3510 Driver(1.6 Hex) for TCMHDL1600 Lingual Extension should be considered for a large defect. Need to have at least 1mm of space above the platform of a fixture: Make this space with a pre-existing abutment, eg,. 2mm >2.5mm horizontal extension needed to make >2mm labial bone after remodeling. >100 blunt angle with bevel should be made to avoid soft tissue irritation. 0.5~ 1.0mm shrinkage will occur after removal of membrane. Apical skirt should be adapted to the bone. Ideal regeneration line

REGENERATION 04/05 How to use Ideal + Regeneration membrane i-gen membrane 1. Place an implant into the recipient site. 2. Connect a i-gen screw to the implant and bone grafting. Usually 1 mm cuff height is good enough for vertical space, but 2 or 3 mm cuff height of can be chosen according to situation. The amount of graft material should be enough to fill the space between i-gen and the fixture. 3. Selection of i-gen and placement. According to the size and shape of bone defect, an i-gen can be chosen from 9 different shapes. Match the hole of i-gen with the screw hole of i-gen screw. 4. Fixate i-gen with a. Choose a i-gen cover Screw or Flat Healing Abutment to fix i-gen membrane depend on the need of one or two stage surgery. And tight adaptation of soft tissue flap is recommended. * We recommend that you verify the size of the abutment screws before use, it should be noted that it may not be fully compatible depending on the tolerance of each manufacturer. M2.0 1.0 IA2010 2.0 IA2020 3.0 IA2030 MegaGen (AnyOne, EZ Plus(R&W) & MegaFix) Straumann (Standard & Standard Plus) Nobel Biocare (Nobel Replace Tapered Groovy) Dentium (Superline) Dio (Steady, SM, IFI) Neobiotech (IS) Osstem (TSⅥ) 1.0 IA1810 M1.8 2.0 IA1820 3.0 IA1830 MegaGen (AnyRidge) Dentsply-Frident (Ankylos C/X Implant) Zimmer (TSV) Which i-gen? i-gen membrane has 9 different size and shapes. M1.6 1.0 IA1610 2.0 IA1620 As seen on the figure left, alveolar bone has different widths according to locations. It can be divided into three categories; Anterior(Sky blue dots), Premolar(Blue dots) and Molar(Dark blue dots). For Anteriors, narrow membranes can be used, which has 4.5mm buccal horizontal extension from the center of fixture. For Premolars, Regular membranes which has 5.5mm buccal extension, can be selected. The molar area usually needs wide membrane (6.5mm from fixture center), especially at the immediate placement case with wall defects. A and B membranes are only to cover single wall defects. C has a lingual extension to cover lingual wall defect. C has a lingual extension to cover lingual wall defect. maxilla i-gen membrane PL (Proximal BW width) Dimension BL BD Distance) mandible A1 A2 A3 4 9 11 4.5 - - IG1W4509 LW (Lingual width) LL (Lingual 4 10 11 5.5 - - IG1W5510 4 11 11 6.5 - - IG1W6511 B1 B2 B3 5 9 11 4.5 - - IG2W0918 3.0 IA1630 MegaGen (EZ Plus Internal _Small) Straumann (Bone Level) 3i (Osseotite certain & Full Osseotite NT Certain) M1.4 MegaGen (MiNi) 1.5 IA1415 2.0 IA1420 3.0 IA1430 BD LL 6.5 11 11 5.5 - - IG2W1120 9 13 11 6.5 - - IG2W1323 BW PL LW BL C1 C2 C3 5 9 11 4.5 6 4.25 IG3W0921 6.5 11 11 5.5 8 4.25 IG3W1125 9 13 11 6.5 10 9 IG3W1328 i-gen Cover Screw Height 1.0 - Use Driver(1.2 Hex) Hex 1.2 1.0 ICS3510

REGENERATION 06 /07 Clinical case Case Ⅰ. Mandibular premolar. This 65 year-old male patient visited with a chief complaint of discomfort on #24 during chewing. On the panoramic view, large bone defect was observed.. The tooth was extracted and socket was degranulated thoroughly. A 4.5mm AnyRidge Fixture was placed at the center of socket with excellent initial stability.. A, 1 mm cuff height, was connected with the fixture. A 1.6mm Hex Driver is needed to place a, which is included in the kit. Mega-Oss allograft was grafted into the defect.. The combined image of i-gen, a i-gen Screw and a Healing Abutment. A Healing Abutment was connected on the i-gen Screw to fix the i-gen for one stage surgical approach. Watch the horizontal extension of i-gen.. Simple suture was made to adapt the buccal flap against the Healing Abutment.. Postoperative panoramic and intraoral radiograph. Fig 7. 3 months after surgery. Gingival healing was excellent and intraoral radiograph showed considerable increase in radiopacity. Fig 8. Usually flap opening is not necessary to remove i-gen, but in this case the flap was elevated to check the bone regeneration. The i-gen was maintained very stable in the tissue, and it was easily removed with a hemostat. Fig 9. The defect was filled with healthy regenerated bone. From the occlusal view, the buccal bone has more than 3mm width at the level of implant platform. 0. Flap was closed with simple suture. Fig 7 Fig 8 Fig 9 0

REGENERATION 08 /09 Case Ⅱ. Maxillary premolar Case Ⅲ. Mandibular incisor area. The first premolar was extracted due to severe periodontitis. Due to the inflammation around that tooth, the implant surgery was delayed almost a month.. When the flaps were elevated, there found two different bone defects: The first premolar showed large extraction socket defect due to periodontitis, and the second premolar showed quite big undercut on the buccal bone. Ostetotomy sockets were made. A big fenestration defect on twas made he second premolar due to bony undercut.. Two 4 x 13 AnyRidge Xpeed fixtures were placed at thwith excellent initial fixation. Look defects around both implants.. Two i-gen screws cuff height, were, 2mm connected due to the irregularity on the crestal bone. The defects were grafted with the mixture of Mega-Oss(allograft) and Bone Plus (synthetic, BCP). Two regular size i-gen ( A) was fixated with healing abutments.. Flaps were closed with simple interrupted sutures, and panoramic and intraoral radiographs were taken after surgery. Fig 7. Healing was uneventful for a month. Intraoral radiograph was taken one month later from surgery.. The first premolar was extracted due to severe periodontitis. Due to the inflammation around that tooth, the implant surgery was delayed almost a month.. Two fixtures were placed on into both lateral incisors. Due to the vertical defect, fixture platforms were positioned about 3 mm above the crest. And again 3mm cuff height Flat abutments were connected to the fixtures to make more space under the membrane.. Mega-Oss bovine was grafted on the horizontal and vertical defects.. Two narrow C i-gen membranes were positioned and fixated with Cover Screws. Then a collagen membrane was placed at the center of the defect.. Primary closure was made with the periosteal releasing.. A panoramic radiograph taken immediate after surgery. Intraoral radiographs taken 1 month after surgery. Find the position of fixture platform, a and i-gen membrane. Fig 7

Full & Trial package ver 2.0 (AnyRidge or AnyOne) Recommended types of i-gen for each tooth (Refer to below table) on material Put on Cover Screw Healing Abutment Full & Trial package ver 2.0 (AnyRidge or AnyOne) Full Package Recommended types of i-gen for each tooth (Refer to below table) on material Put on Cover Screw Healing Abutment / 6ea 2.5mm / 3ea 3.5mm / 3ea Full Package i-gen full package includes - 12 i-gen membranes - 12 s (1mm, 2mm, 3mm cuff x 4 each) - 6 Cover Screws - 6 Healing Abutments (2.5, 3.5 mm height) - 1 Driver (Hex 1.6) / 6ea 2.5mm / 3ea 3.5mm / 3ea Trial Package 1mm Cuff / 2ea 2mm Cuff / 2ea 3mm Cuff / 2ea / 2ea 2.5mm / 2ea 3.5mm / 2ea i-gen trial package includes - 6 i-gen membranes - 6 s (1mm x 2ea, 2mm x 1ea, 3mm x 1ea) - 2 Cover Screws - 4 Healing Abutments (2.5 & 3.5 mm height) - 1 Driver (Hex 1.6) Individual items can be ordered additionally to fill up the package. Additional types of for other implant system are available upon request. Ask to your sales reps.