A New Low-Friction Ligation System

Similar documents
An in vitro investigation of the influence of self-ligating brackets, low friction ligatures, and archwire on frictional resistance

In Vitro Frictional Forces Generated by Three Different Ligation Methods

There has been increased use of self-ligating. Friction between various self-ligating brackets and archwire couples during sliding mechanics

Sliding mechanics in an extraction case treated with 3M Clarity ADVANCED Ceramic Brackets and the 3M MBT Appliance System.

ABSTRACT INTRODUCTION /jp-journals

ORTHOdontics SLIDING MECHANICS

Introduction. Formerly known as Susan David

A Comparison of Frictional Resistance between Active and Passive Self-ligating Brackets with Conventional Bracket Systems

Third-Order Torque and Self-Ligating Orthodontic Bracket Type Effects on Sliding Friction

A study of the frictional characteristics of four commercially available self-ligating bracket systems

The Tip-Edge appliance and

An estimated 25-30% of all orthodontic patients can benefit from maxillary

2007 JCO, Inc. May not be distributed without permission.

Introducing the Clarity SL Self-Ligating Appliance System

Plus Combines Traditional Twin Bracket Treatment With Self-Ligation Convenience

ANTERIOR AND CANINE RETRACTION: BIOMECHANIC CONSIDERATIONS. Part One

Experience with Contemporary Tip-Edge plus Technique A Case Report.

Evaluation of methods of archwire ligation on frictional resistance

The management of impacted

2008 JCO, Inc. May not be distributed without permission. Correction of Asymmetry with a Mandibular Propulsion Appliance

INCLUDES: OVERVIEW ON CLINICAL SITUATIONS FREQUENTLY ENCOUNTERED IN ORTHODONTIC TREATMENTS MECHANOTHERAPY USED TO RESOLVE THESE SITUATIONS

Tooth movement can occur when the applied

Delta Force. Bracket System. Putting you in the driver s seat for ultimate control

Frictional resistance in monocrystalline ceramic brackets with conventional and nonconventional elastomeric ligatures

INDICATIONS. Fixed Appliances are indicated when precise tooth movements are required

The Science Behind The System Clinical Abstracts, Volume 2

HYCON DEVICE: A PRECISE AND CONTROLLED METHOD OF SPACE CLOSURE A CASE REPORT

In vitro comparative study on the friction of stainless steel wires with and without Orthospeed (JAL 90458) on an inclined plane

FRICTION PRODUCED BY ESTHETIC BRACKETS WITH VARYING LIGATION CHRISTINE KNOX ABENOJA

Molar anchorage loss has been shown to occur

A comparative study of the static and kinetic frictional resistance of titanium molybdenum alloy archwires in stainless steel brackets

Archwire Insertion and Disengagement Instruments Technique Guide

Use of a Tip-Edge Stage-1 Wire to Enhance Vertical Control During Straight Wire Treatment: Two Case Reports

Space Closure Biomechanics Applied Using The MBT System Technique

Frictional Properties of Self-Ligating Brackets and Low-Friction Ligatures

Frictional Resistance in Various Ceramic Brackets using Archwires of different Alloys, Sizes and Cross sections: A Comparative Study

Controlled Space Closure with a Statically Determinate Retraction System

Orthodontic Treatment Using The Dental VTO And MBT System

A Modified Three-piece Base Arch for en masse Retraction and Intrusion in a Class II Division 1 Subdivision Case

Canine Extrusion Technique with SmartClip Self-Ligating Brackets

6. Timing for orthodontic force

MBT System as the 3rd Generation Programmed and Preadjusted Appliance System (PPAS) by Masatada Koga, D.D.S., Ph.D

Integrative Orthodontics with the Ribbon Arch By Larry W. White, D.D.S., M.S.D.

Dual Force Cuspid Retractor

A New Fixed Interarch Device for Class II Correction

An Evaluation of Efficiency and Effectiveness of Self-ligating Bracket Systems: A Prospective Clinical Study

Crowding and protrusion treated by unusual extractions

LIMITING FACTORS AFFECTING STAGE I TREATMENT: A BIOMECHANICAL PERSPECTIVE. Christopher G. Gibson. Chapel Hill 2016

Dental Materials Journal 2015; 34(3): Keisuke TOCHIGI, Souichiro ODA and Kazuhito ARAI INTRODUCTION

System Orthodontic Treatment Program By Dr. Richard McLaughlin, Dr. John Bennett and Dr. Hugo Trevisi

MemRx Orthodontic Appliances

SE NiTi Heat Activated NiTi Ultra T Heat Activated NiTi Stainless Steel Beta Titanium. Ultra T Archwires

THE MBT VERSATILE+ APPLIANCE SYSTEM

Self-ligating versus Invisalign: analysis of dento-alveolar effects

From Plan B to Plan A : Using Forsus Class II Correctors as a Regular Mode of Treatment

Frictional properties of aesthetic brackets

The Tip-Edge Concept: Eliminating Unnecessary Anchorage Strain

Anchorage system. tomas / Sets Page 270 tomas / Pins Page 271 Instruments and accessories Page 273 Patient consultation material Page 282

Characterizing constraining forces in the alignment phase of orthodontic treatment

04 Inserting the HYCON TUBE

Advantages. Fantastic. systems. Together with Unitek Lateral Development Archwires, this system puts you in control to

Advantages. Fantastic. Treatment. Finishes. 3M Self-Ligating Appliances Lateral Development System. Unitek Lateral Development Archwires

Forsus Class II Correctors as an Effective and Efficient Form of Anchorage in Extraction Cases

Intraoral molar-distalization appliances that

Treatment of Class II, Division 2 Malocclusion in Adults: Biomechanical Considerations FLAVIO URIBE, DDS, MDS RAVINDRA NANDA, BDS, MDS, PHD

A randomized clinical trial to compare three methods of orthodontic space closure

The Comparison of Space Closure Rate between Conventional and Passive Self-ligating System Using Elastomeric Chain in Maxilla

AL-AZHAR. Dental Journal. Print ISSN Online ISSN ADJ-for Girls, Vol. 5, No. 1, January (2018) PP. 9:14

Comparative Biomechanics of Labial versus Lingual Fixed Appliances - A Review

Aesthetic Brackets and Accessories

BRACKET CHOICES SYSTEM CHOICES. Empower 2 reconvertible molar tubes provide versatility without compromise.

Victory Series Active Self-Ligating Brackets. Reliable. and. Effective

A review of the orthodontic literature

Developing lingual orthodontics

Frictional resistance exerted by different lingual and labial brackets: an in vitro study

ARCHWIRE. An extensive selection of high quality wire types and arch forms WIRE PRODUCTS. Wires. TruFlex Nickel Titanium Archwire. TruFlex.

Treatment of an open bite case with 3M Clarity ADVANCED Ceramic Brackets and miniscrews.

The effectiveness of laceback ligatures: A randomized controlled clinical trial

A finite element analysis of the effects of archwire size on orthodontic tooth movement in extraction space closure with miniscrew sliding mechanics

Is nickel titanium superior to multistranded stainless steel wire in aligning crowded lower anteriors? A comparative in-vivo study.

REPRINTED FROM JOURNAL OF CLINICAL ORTHODONTICS 1828 PEARL STREET, BOULDER, COLORADO Dr. Nanda Dr. Marzban Dr. Kuhlberg

The 20/20 Molar Tube. Ronald M. Roncone, D.D.S., M.S.

Measurements of the torque moment in various archwire bracket ligation combinations

The Study of Frictional Force in Self-Ligating Orthodontic Brackets

Simply Great Wire! Great prices.

TURN CLASS II INTO SIMPLE CLASS I PATIENTS.

Comparison of Frictional Resistance in Conventional Brackets with Different Stainless Steel Wires

UNILATERAL UPPER MOLAR DISTALIZATION IN A SEVERE CASE OF CLASS II MALOCCLUSION. CASE PRESENTATION. 1*

Orthodontic bracket slot dimensions as measured from entire bracket series

Honing Damon System Mechanics for the Ultimate in Efficiency and Excellence Jeff Kozlowski, DDS East Lyme, CT

The effect of surface treatment and clinical use on friction in NiTi orthodontic wires

Indian Journal of Basic and Applied Medical Research; June 2014: Vol.-3, Issue- 3, P

LINGUAL STRAIGHTWIRE BRACKET SYSTEM Designed with Drs. Kyoto Takemoto and Giuseppe Scuzzo

Correction of Crowding using Conservative Treatment Approach

The role of friction in orthodontics

Effect of Brackets Types on the Amount of Movement and Rotation of Canine during Retraction: A Simulated In vitro Study

SnapLink Re-Convertible Tube

Crowded Class II Division 2 Malocclusion

We Give Back. Reduce Emergency Visits! ATTACHMENTS. No More Poking Archwires! Crimpable Mini Stops. Tooth Tone Crimpable Mini Stops

wiirre e a a n n d d w wiirre e ffo orrms ms

Transcription:

2005 JCO, Inc. May not be distributed without permission. www.jco-online.com A New Low-Friction Ligation System ARTURO FORTINI, MD, DDS MASSIMO LUPOLI, MD, DDS VITTORIO CACCIAFESTA, DDS, MS Many factors can contribute to the frictional resistance of edgewise appliances, 1-7 including bracket and wire materials and cross-sections, surface conditions of the archwires and bracket slots, torque at the wire-bracket interface, interbracket distance, the presence of saliva, and the functions of the oral environment. 8-11 Schumacher and colleagues found, however, that friction was determined mostly by the type and force of ligation. 12 The first self-ligating bracket was the Russell attachment, introduced in the mid-1930s to reduce chairtime and improve operator efficiency. 13,14 More recently, two broad classifications of self-ligating brackets have been developed: the active type, in which the spring clip presses against the archwire (SPEED,* In-Ovation,** Time***), and the passive type, in which the clip does not contact the wire (TwinLock, Damon ). Every self-ligating bracket, whether active or passive, uses the movable fourth wall of the bracket to convert the slot into a tube. Several studies have demonstrated a significant reduction *Trademark of Strite Industries Ltd., 298 Shepherd Ave., Cambridge, Ontario, N3C 1V1 Canada. **Trademark of GAC International, 355 Knickerbocker Ave., Bohemia, NY 11716. ***Registered trademark of Adenta GmbH, P.O. Box 82199, Gutenbergstr. 9, D-82205 Gilching, Germany. Trademark of Ormco/ A Company, 1717 W. Collins Ave., Orange, CA 92867. Leone, Via P. a Quaracchi, Sesto Fiorentino, Italy. in friction with self-ligating brackets compared to conventional designs. 3,15-20 This can help shorten treatment, especially in extraction cases, where tooth translation is achieved by sliding mechanics. Self-ligating systems do have several limitations, however: Full expression of bracket torque is difficult to achieve. Clinical management is more problematic than with conventional brackets due to frequent failure of the clips. The brackets are bulkier and more expensive than other edgewise brackets. Oral hygiene is more difficult because of the brackets complex geometry. This article describes an alternative to selfligating systems: a ligature that markedly reduces the amount of friction between the archwire and the edgewise bracket. The Slide ligature enables the archwire to apply the desired amount of force without the resistance of conventional ligatures, thus reducing treatment time and producing more stable results. Low-Friction Ligature System The Slide ligature, made of a special medical polyurethane, is applied to the bracket in the same way as a conventional elastomeric ligature (Fig. 1). Like a passive self-ligating bracket, it Fig. 1 Slide low-friction ligature tied into edgewise bracket. 464 2005 JCO, Inc.

Dr. Fortini is a Clinical Assistant Professor and Dr. Cacciafesta is an Assistant Professor, Department of Orthodontics, University of Pavia, Pavia, Italy. Dr. Lupoli is a Visiting Professor, Department of Maxillofacial Surgery, University of Florence. Dr. Cacciafesta is also an Assistant Professor, University of Insubria, Varese, Italy, and is in the private practice of orthodontics in Pavia. Dr. Lupoli is also in the private practice of orthodontics in Florence, and Dr. Fortini is in the private practice of orthodontics at Via G. Meoni 48-52, 59100 Prato, Italy; e-mail: artfort@tin.it. Dr. Fortini Dr. Lupoli Dr. Cacciafesta allows the archwire to slide freely in the slot while transmitting its full force to the tooth (Fig. 2). The Slide ligature also forms a buffer between the brackets and the soft tissues, considerably improving patient comfort (Fig. 3). Slide ligatures are specifically designed for use with STEP brackets, but are available in three sizes to fit any type of edgewise appliance, including ceramic brackets (Fig. 4). To meet the demands of younger patients, the ligatures are manufactured in various colors (Fig. 5). Slide ligatures can be used in cases where considerable leveling and alignment are required, A B Fig. 3 Difference in thickness of STEP brackets with Slide ligatures (A) compared to self-ligating Damon 2 brackets (B). Fig. 4 Slide ligatures with ceramic brackets. Fig. 2 Slide ligature forms fourth wall of slot, allowing archwire to slide freely while transmitting full force to tooth. Fig. 5 Various colors of Slide ligatures. VOLUME XXXIX NUMBER 8 465

A New Low-Friction Ligation System Fig. 6 Slide brackets used on cuspid and premolar brackets for sliding mechanics during space closure. Fig. 7 Case 1. 12-year-old female patient with bimaxillary protrusion, severe crowding in both arches, and transposed upper right canine and first premolar. Fig. 8 Case 1. Upper.020" stainless steel archwire and compressed-coil spring used to move right canine mesially; lower.014" superelastic nickel titanium archwire tied in with Slide ligatures. A B C Fig. 9 Case 1. A. Patient at start of treatment. B. Lower.016" superelastic nickel titanium archwire used with elastic chain for extraction space closure. C. Lower left canine completely aligned after eight weeks. 466

Fortini, Lupoli, and Cacciafesta as well as in patients who need sagittal or transverse expansion. The advantages of the system are especially evident in the early stages of orthodontic treatment, when the archwire can slide freely inside the tunnel between the bracket slot and the ligature. The system also enables the clinician to apply friction and reduced-friction mechanics simultaneously on the same archwire by using Slide ligatures only in particular segments. For example, during en masse space closure on a rectangular stainless steel archwire, Slide ligatures can be used in the posterior segments to reduce friction, while conventional ligatures are used in the anterior segment to maximize torque expression and control (Fig. 6). Case 1 A 12-year-old female presented with a bimaxillary protrusion, severe crowding in both arches, and transposition of the upper right canine and first premolar (Fig. 7). After extraction of the right first premolars, preadjusted STEP brackets were bonded in the upper arch, and an.020" Gold Tone stainless steel archwire and compressed-coil spring were used to move the upper right canine mesially (Fig. 8). In the lower arch, an.014" superelastic nickel titanium archwire was tied into preadjusted STEP brackets with Slide low-friction ligatures. Once the lower left canine had been partially aligned, the archwire was changed to.016" superelastic nickel titanium; the extraction space was closed with elastic chain (Fig. 9). After eight weeks of treatment, the lower left canine was in proper position. Case 2 In this 11-year-old female with a Class II malocclusion, the initial upper molar distalization was retained with a modified Nance button (Fig. 10). An upper.014" superelastic nickel titanium archwire was then tied into preadjusted STEP brackets with Slide ligatures (Fig. 11). No lacebacks were required to move the upper right canine. In the lower arch, an.020" Gold Tone stainless steel archwire was placed with bend- Leone, Via P. a Quaracchi, Sesto Fiorentino, Italy. Fig. 10 Case 2. 11-year-old female Class II patient after initial upper molar distalization, retained with modified Nance button. VOLUME XXXIX NUMBER 8 467

A New Low-Friction Ligation System Fig. 11 Case 2. Upper.014" superelastic nickel titanium archwire, with Slide ligatures and no lacebacks; lower.020" stainless steel archwire with bend-backs. Fig. 12 Case 2. Upper right canine leveled after 32 days without intrusion of adjacent teeth. backs. After 32 days of this phase of treatment, the upper right canine had been leveled without any intrusive side effects on the adjacent teeth or posterior anchorage reinforcement (Fig. 12). Case 3 A 13-year-old female presented with a skeletal and dental Class III malocclusion (Fig. 13). Preadjusted STEP brackets were bonded in the upper arch, and an.016" Gold Tone stainless steel archwire was inserted with a laceback to the left canine (Fig. 14). Low-friction mechanics were then initiated with an.014" superelastic nickel titanium archwire, using Slide ligatures and no lace- or bendbacks (Fig. 15). Enough space was gained in seven weeks to align the upper right canine (Fig. 16). Conclusion The user-friendly Slide low-friction ligature can be employed with any edgewise bracket without altering the clinician s preferred mechanotherapy. This system offers advantages over self-ligating brackets in controlling friction, while increasing patient comfort and potentially reducing treatment time. (text continued on p. 470) 468

Fortini, Lupoli, and Cacciafesta Fig. 13 Case 3. 13-year-old female patient with skeletal and dental Class III malocclusion. Fig. 14 Case 3. Upper.016" stainless steel archwire with laceback to left canine. Fig. 15 Case 3. Low-friction mechanics with.014" superelastic nickel titanium archwire and Slide ligatures. VOLUME XXXIX NUMBER 8 469

A New Low-Friction Ligation System Fig. 16 Case 3. Alignment of upper right canine after seven weeks of treatment. REFERENCES 1. Omana, H.M.; Moore, R.N.; and Bagby, M.D.: Frictional properties of metal and ceramic brackets, J. Clin. Orthod. 26:425-432, 1992. 2. Besancon, R.M.: The Encyclopedia of Physics, 3rd ed., Van Nostrand Reinhold Company, New York, 1985. 3. Pizzoni, L.; Ravnholt, G.; and Melsen, B.: Frictional forces related to self-ligating brackets, Eur. J. Orthod. 20:283-291, 1998. 4. Loftus, B.P.; Årtun, J.; Nicholls, J.I.; Alonzo, T.A.; and Stoner, J.A.: Evaluation of friction during sliding tooth movement in various bracket-arch wire combinations, Am. J. Orthod. 116:336-345, 1999. 5. Kapur, R.; Sinha, P.K.; and Nanda, R.S.: Comparison of frictional resistance in titanium and stainless steel brackets, Am. J. Orthod. 116:271-274, 1999. 6. Ogata, R.H.; Nanda, R.S.; Duncanson, M.G. Jr.; Sinha, P.K.; and Currier, G.F.: Frictional resistance in stainless steel bracket-wire combinations with effects of vertical deflections, Am. J. Orthod. 109:535-542, 1996. 7. Proffit, W.R. and Fields, H.V.: The biological basis of orthodontic therapy, in Contemporary Orthodontics, C.V. Mosby, St. Louis, 1993, pp. 266-288. 8. Andreasen, G.F. and Quevedo, F.R.: Evaluation of friction forces in the 0.022 x 0.028 edgewise bracket in vitro, J. Biomech. 3:151-160, 1970. 9. Kapila, S.; Angolkar, P.V.; Duncanson, M.G.; and Nanda, R.S.: Evaluation of friction between edgewise stainless steel brackets and orthodontic wires of four alloys, Am. J. Orthod. 98:117-126, 1990. 10. Rose, C.M. and Zernik, J.H.: Reduced resistance to sliding in ceramic brackets, J. Clin. Orthod. 30:78-84, 1996. 11. Braun, S.; Bluestein, M.; Moore, B.K.; and Benson, G.: Friction in perspective, Am. J. Orthod. 115:619-627, 1999. 12. Schumacher, H.A.; Bourauel, C.; and Drescher, D.: The effect of the ligature on the friction between bracket and arch, Fortschr. Kieferorthop. 51:106-116, 1990. 13. Stolzenberg, J.: The Russell attachment and its improved advantages, Int. J. Orthod. Dent. Child. 21:837-840, 1935. 14. Stolzenberg, J.: The efficiency of the Russell attachment, Am. J. Orthod. 32:572-582, 1946. 15. Berger, J.L.: The influence of the SPEED bracket s self-ligating design on force levels in tooth movement: A comparative in vitro study, Am. J. Orthod. 97:219-228, 1990. 16. Sims, A.P.T.; Waters, N.E.; Birnie, D.J.; and Pethybridge, R.J.: A comparison of the forces required to produce tooth movement in vitro using two self-ligating brackets and a pre-adjusted bracket employing two types of ligation, Eur. J. Orthod. 15:377-385, 1993. 17. Sims, A.P.T.; Waters, N.E.; and Birnie, D.J.: A comparison of the forces required to produce tooth movement ex vivo through three types of pre-adjusted brackets when subjected to determined tip or torque values, Br. J. Orthod. 21:367-373, 1994. 18. Read-Ward, G.E.; Jones, S.P.; and Davies, E.H.: A comparison of self-ligating and conventional orthodontic bracket systems, Br. J. Orthod. 24:309-317, 1997. 19. Thomas, S.; Sherriff, M.; and Birnie, D.: A comparative in vitro study of the frictional characteristics of two types of self-ligating brackets and two types of pre-adjusted edgewise brackets tied with elastomeric ligatures, Eur. J. Orthod. 20:589-596, 1998. 20. Thorstenson, G.A. and Kusy, R.P.: Resistance to sliding of selfligating brackets versus conventional stainless steel twin brackets with second-order angulation in the dry and wet (saliva) states, Am. J. Orthod. 120:361-370, 2001. 470