A knowledge-based cone-beam x-ray CT algorithm for dynamic volumetric cardiac imaging

Similar documents
Importance of early diagnosis of cardiovascular diseases

Introduction. Cardiac Imaging Modalities MRI. Overview. MRI (Continued) MRI (Continued) Arnaud Bistoquet 12/19/03

Coronary CT Angiography

Improvement of Image Quality with ß-Blocker Premedication on ECG-Gated 16-MDCT Coronary Angiography

General Cardiovascular Magnetic Resonance Imaging

MR Advance Techniques. Cardiac Imaging. Class IV

Department of Cardiology, Grosshadern Clinic, University of Munich, Marchioninistrasse 15, Munich, Germany. Department of Cardiology,

Sang Ho Lee, Byoung Wook Choi, Hee-Joung Kim*, Member, IEEE, Haijo Jung, Hye-Kyung Son, Won-Suk Kang, Sun Kook Yoo, Kyu Ok Choe, Hyung Sik Yoo

Ultrasound. Computed tomography. Case studies. Utility of IQon Spectral CT in. cardiac imaging

MR Advance Techniques. Vascular Imaging. Class II

Cardiac CT - Coronary Calcium Basics Workshop II (Basic)

Towards Cardiac C-Arm Computed Tomography Günter Lauritsch*, Jan Boese, Lars Wigström, Herbert Kemeth, and Rebecca Fahrig

Combined Anatomical and Functional Imaging with Revolution * CT

Measurement of Respiratory and Cardiac Motion Using a Multi Antenna Continuous Wave Radar Operating in the Near Field

Shock-induced termination of cardiac arrhythmias

Electron Beam CT versus 16-slice Spiral CT: How Accurately Can We Measure. Coronary Artery Calcium Volume?

37 1 The Circulatory System

IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 51, NO. 1, FEBRUARY

Adapted Transfer Function Design for Coronary Artery Evaluation

Health Science 20 Circulatory System Notes

An Introduction to Dual Energy Computed Tomography

Cardiac Computed Tomography

Electron Beam CT of the Heart

ECG. Prepared by: Dr.Fatima Daoud Reference: Guyton and Hall Textbook of Medical Physiology,12 th edition Chapters: 11,12,13

Cardiac Imaging Tests

Improvement of cardiac imaging in electrical impedance tomography by means of a new

Chapter 13 The Cardiovascular System: Cardiac Function

Lab #3: Electrocardiogram (ECG / EKG)

The Cardiac Cycle Clive M. Baumgarten, Ph.D.

Cardiac Cycle. Each heartbeat is called a cardiac cycle. First the two atria contract at the same time.

Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement

Coronary angiography is the standard way of visualizing

Quantitative and Qualitative Assessment of Thorax Cone Beam CT Image Quality across Multiple Imaging Systems

Signal Processing of Stress Test ECG Using MATLAB

On the feasibility of speckle reduction in echocardiography using strain compounding

Toshiba Aquillion 64 CT Scanner. Phantom Center Periphery Center Periphery Center Periphery

Lab 16. The Cardiovascular System Heart and Blood Vessels. Laboratory Objectives

Outline. Electrical Activity of the Human Heart. What is the Heart? The Heart as a Pump. Anatomy of the Heart. The Hard Work

A Snapshot on Nuclear Cardiac Imaging

Matters of the Heart: Comprehensive Cardiology SARAH BEANLANDS RN BSCN MSC

Magnetic Resonance Angiography

Electrocardiography I Laboratory

Interpreting Electrocardiograms (ECG) Physiology Name: Per:

Non Contrast MRA. Mayil Krishnam. Director, Cardiovascular and Thoracic Imaging University of California, Irvine

Myocardial Twist from X-ray Angiography

Modifi ed CT perfusion contrast injection protocols for improved CBF quantifi cation with lower temporal sampling

Measurement of Ventricular Volumes and Function: A Comparison of Gated PET and Cardiovascular Magnetic Resonance

X-Ray & CT Physics / Clinical CT

ELECTROCARDIOGRAPHY (ECG)

Circulatory system of mammals

PART I. Disorders of the Heart Rhythm: Basic Principles

Low Dose Era in Cardiac CT

Imaging Strategies for Endovascular Cardiovascular Procedures and Percutaneous Aortic Valves. Roy K Greenberg, MD

Comparison of Different ECG Signals on MATLAB

Horizon Scanning Technology Summary. Magnetic resonance angiography (MRA) imaging for the detection of coronary artery disease

Introduction to ECG Gary Martin, M.D.

CFD Challenge: Simulation of Hemodynamics in a Patient-Specific Aortic Coarctation Model

b. To facilitate the management decision of a patient with an equivocal stress test.

CARDIOVASCULAR SYSTEM

Chapter 20: Cardiovascular System: The Heart

Objectives of the Heart

Topic 6: Human Physiology

: Biomedical Signal Processing

Biases affecting tumor uptake measurements in FDG-PET

ACR MRI Accreditation: Medical Physicist Role in the Application Process

Multiple Gated Acquisition (MUGA) Scanning

Cardiovascular Physiology

Removal of Baseline Wander from Ecg Signals Using Cosine Window Based Fir Digital Filter

Practice Exercises for the Cardiovascular System

Contents 1 Computational Haemodynamics An Introduction 2 The Human Cardiovascular System

, David Stultz, MD. Cardiac CT. David Stultz, MD Cardiology Fellow, PGY 6 March 28, 2006

Applying a Level Set Method for Resolving Physiologic Motions in Free-Breathing and Non-Gated Cardiac MRI

Dr Felix Keng. Imaging of the heart is technically difficult because: Role of Cardiac MSCT. Current: Cardiac Motion Respiratory Motion

University of Groningen. Quantitative CT myocardial perfusion Pelgrim, Gert

The Mammalian Circulatory System

UK Biobank. Imaging modality Cardiovascular Magnetic Resonance (CMR) Version th Oct 2015

FOR CMS (MEDICARE) MEMBERS ONLY NATIONAL COVERAGE DETERMINATION (NCD) FOR MAGNETIC RESONANCE IMAGING:

INTRODUCTION TO ECG. Dr. Tamara Alqudah

ECG Signal Characterization and Correlation To Heart Abnormalities

Electrical Conduction

MULTILEAD SIGNAL PREPROCESSING BY LINEAR TRANSFORMATION

Heart. Heart 2-Tunica media: middle layer (media ='middle') muscle fibers (smooth or cardiac).

Biomedical Imaging: Course syllabus

IP: Regulation of Cardiac Output

Automatic cardiac contour propagation in short axis cardiac MR images

Improving Diagnostic Accuracy of MDCT Coronary Angiography in Patients with Mild Heart Rhythm Irregularities Using ECG Editing

Calcium scoring using 64-slice MDCT, dual source CT and EBT: a comparative phantom study

CARDIAC CYCLE CONTENTS. Divisions of cardiac cycle 11/13/13. Definition. Badri Paudel GMC

Usefulness of New CT Technologies for Interventional Cardiovascular Procedures

Previous talks. Clinical applications for spiral flow imaging. Clinical applications. Clinical applications. Coronary flow: Motivation

Automated Detection of Polyps from Multi-slice CT Images using 3D Morphologic Matching Algorithm: Phantom Study

Cardiovascular System Notes: Physiology of the Heart

ISSUES ON COMPUTATIONAL MODELING FOR COMPUTATION-AIDED DIAGNOSIS 臨床診断支援ツールのための計算力学モデリング

Introduction to Biomedical Imaging

This presentation will deal with the basics of ECG description as well as the physiological basics of

Raja Muthupillai, PhD. Department of Diagnostic and Interventional Radiology St. Luke s Episcopal Hospital. Research Support: Philips Healthcare

Computed tomography. Department of Radiology, University Medical School, Szeged

Hemodynamic Assessment. Assessment of Systolic Function Doppler Hemodynamics

A Dynamic model of Pulmonary Vein Electrophysiology. Harry Green 2 nd year Ph.D. student University of Exeter

Transcription:

A knowledge-based cone-beam x-ray CT algorithm for dynamic volumetric cardiac imaging Ge Wang a) Department of Radiology, University of Iowa, Iowa City, Iowa 52242 Shiying Zhao Department of Mathematics and Computer Science, University of Missouri St. Louis, St. Louis, Missouri 63121 Dominic Heuscher CT Advanced Systems Group, Philips Medical Systems, 595 Miner Road, Cleveland, Ohio 44143 Received 28 September 2001; accepted for publication 29 May 2002; published 24 July 2002 With the introduction of spiral/helical multislice CT, medical x-ray CT began a transition into cone-beam geometry. The higher speed, thinner slice, and wider coverage with multislice/conebeam CT indicate a great potential for dynamic volumetric imaging, with cardiac CT studies being the primary example. Existing ECG-gated cardiac CT algorithms have achieved encouraging results, but they do not utilize any time-varying anatomical information of the heart, and need major improvements to meet critical clinical needs. In this paper, we develop a knowledge-based spiral/ helical multislice/cone-beam CT approach for dynamic volumetric cardiac imaging. This approach assumes the relationship between the cardiac status and the ECG signal, such as the volume of the left ventricle as a function of the cardiac phase. Our knowledge-based cardiac CT algorithm is evaluated in numerical simulation and patient studies. In the patient studies, the cardiac status is estimated initially from ECG data and subsequently refined with reconstructed images. Our results demonstrate significant image quality improvements in cardiac CT studies, giving clearly better clarity of the chamber boundaries and vascular structures. In conclusion, this approach seems promising for practical cardiac CT screening and diagnosis. 2002 American Association of Physicists in Medicine. DOI: 10.1118/1.1494989 Key words: x-ray computed tomography CT, spiral/helical CT, multislice/cone-beam CT, dynamic volumetric imaging, cardiac imaging, electrocardiogram ECG, multiphase/state reconstructions I. INTRODUCTION It is widely known that cardiac diseases are of paramount importance in health care, and the number one killer in the USA. Over half of the individuals who die of a coronary attack have no recorded symptoms http:// www.americanheart.org/statistics/index.html. There is an important and immediate need for early screening and accurate diagnosis of cardiac diseases. In this aspect, noninvasive imaging techniques are invaluable. The imaging modalities available today are not fully satisfactory, including cardiac angiography, ultrasound, magnetic resonance imaging MRI, electron-beam CT EBCT, and spiral CT. 1 Cardiac angiography, being the gold standard, is invasive. Ultrasound, as a cost-effective method, suffers from poor image quality. MRI, as a powerful modality, fails to detect calcification, and is subject to various artifacts. EBCT, 2 with the fastest speed, is not widely available and suffers from limited spatial and contrast resolution. Although they are most promising, current spiral/helical CT scanners, even with ECG gating, often cannot accurately depict boundaries of the cardiac structures, nor quantify small amounts of calcium reliably, especially when the heart rate is high. Multi-slice spiral CT MSCT has attracted increasing interest since its recent introduction. 3,4 Compared with singleslice systems, MSCT scanners allow faster data collection, thinner slices, and wider coverage. With the rapid development of MSCT technology, cone-beam CT CBCT should be the future of medical x-ray CT. 5 In the near future, the small cone angle will be expanded to medium cone angles by adding more detector rows. Eventually, large cone angles will very likely be used. CBCT has a great potential for dynamic volumetric imaging, with cardiac CT studies being the primary example. There are important dynamic imaging algorithms in the literature. The idea of gating for imaging of periodically varying structures was reported in the early 1980s. 6 8 The gating scheme measures an indicative periodic motion function. This signal is used to identify a quiescent period in the periodic motion so that the acquisition of projection data may be coordinated to be centered within the quiescent period. 9 Ohnesorge et al. performed a systematic phantom experiment to study ECG-gated CT images. 6 Stop-action reconstructed images revealed two types of artifacts: a pinwheel artifacts near high-contrast moving objects; and b streaks corresponding to missing views. Joseph and Whitley utilized the ECG to select the phase of the cardiac cycle being imaged. 7 Their technique assesses the diagnostic utility 1807 Med. Phys. 29 8, August 2002 0094-2405Õ2002Õ29 8 Õ1807Õ16Õ$19.00 2002 Am. Assoc. Phys. Med. 1807

1808 Wang, Zhao, and Heuscher: Dynamic volumetric cardiac imaging 1808 of images reconstructed from a limited number of projections within a cardiac region of interest. To reduce artifacts due to periodic variation in reconstructed images, Glover and Pelc developed a method for transforming an indicative periodic motion function into that distributing events more evenly over the motion period. 10 Ritchie et al. studied respiratory motion artifact reduction and developed a pixelspecific filtered backprojection algorithm. 11,12 In their algorithm, in-plane motion is corrected by performing the reconstruction with a coordinate system specific to each pixel. The coordinate system moves according to the inplane motion in the section at the time the projection is acquired. Their study was mainly evaluated for lung reconstruction with incremental CT. However, cardiac motion is much more difficult to model than respiratory motion, and incremental CT, though useful for some prospectively gated applications, can only image one phase of the cardiac cycle with limited spatial resolution. Wang and Vannier considered rigid and in-plane motion artifact reduction in spiral CT. 13 Willis and Bresler reported their work on reconstruction of objects with temporal variation. 14,15 They formulated the problem as signal recovery from time-sequential samples of a spatially and temporally band-limited signal, where one angular-independent view can be taken at a time. This requirement cannot be met by current MSCT/CBCT. Spiral CT was recognized quite early as having a significant advantage in imaging moving anatomy. 16,17 With spiral MSCT, the heart can now be scanned within a single breathold with excellent spatial resolution. Much investigation has been done into optimizing the scanning protocols and reconstruction algorithms using ECG-gating information. 18 Taguchi and Anno developed a MSCT algorithm for imaging rapidly moving organs, such as the heart and adjacent pulmonary vessels. 19 The proposed algorithm performs the interpolation of raw projection data based on the acquisition time. Nevertheless, their algorithm assumes no knowledge about periodic organ motion. Kachelriess et al. described two ECG-gated MSCT algorithms for cardiac imaging 20,21 that improve image quality compared with the standard nongated commercial reconstruction algorithms, but their approach does not take into account any anatomical knowledge of the heart as a function of time in the cardiac cycle. In addition, MSCT currently still requires an extended breathold time. The most consistent images are achieved for lower heart rates approximately 70 bpm or less while selecting the optimal phase within the heart cycle. We are committed to advancing the state of the art of spiral MSCT/CBCT, and developing it into a vital tool for clinical cardiac imaging. We hypothesize that a welldesigned MSCT/CBCT algorithm can significantly improve image quality in cardiac studies, providing an accurate assessment of heart function, extent of coronary stenosis, and quantification of coronary calcification. In this paper, we develop a knowledge-based approach for dynamic volumetric cardiac CT. The technical motivation is to effectively estimate and utilize temporal and spatial information of the beating heart, exploit all raw projection data, and reconstruct the heart with the highest possible clarity in any state of the cardiac cycle. These unique characteristics are achieved by optimizing the strategy for selecting and merging segments of raw data based on the relationship between the cardiac status and the ECG. In other words, data segments are collected when the heart or a component of the heart, for example, the left ventricle is in a consistent state for example, in similar volumes so that image reconstruction produces the best quality for any specified state. In the following, we first provide some basics on the heart and cardiac motion, and formulate our dynamic volumetric MSCT/CBCT scheme, with an emphasis on the cardiac motion modeling and MSCT/CBCT data selection/interpolation strategy. Then, we describe mathematical phantoms and numerical simulation. Also, we apply our algorithm in patient studies. Finally, we discuss several related issues as further research directions. II. METHODS AND MATERIALS A. Cardiac motion model The heart, consisting of two synchronized pumps, is the key organ of the circulatory system. The right pump pushes the blood through the lungs, while the left pump forces the blood through the peripheral organs. Each pump has two chambers: an atrium and a ventricle. The atrium moves the blood into the ventricle. The ventricle propels the blood through either the pulmonary or peripheral circulation. Special mechanisms control the heart rhythm by transmitting action potentials throughout the heart muscle. The cardiac cycle is associated with the heartbeat, which is initiated by an electrical potential in the sinus node. This potential travels rapidly through the atria into the ventricles. The cardiac cycle is featured by a period of relaxation called diastole and a period of contraction called systole. Figure 1 illustrates the different physiological events in the cardiac cycle. The top three curves show the pressure changes in the aorta, left ventricle, and left atrium, respectively. Most importantly, the fourth curve depicts the volume change of the left ventricle, the fifth curve the ECG. Also, of potential value is the sixth curve, a phonocardiogram that records sounds produced by the heart. Being of great clinical significance, without loss of generality, and to the first order of approximation, the volume of the left ventricle can be used to represent the instantaneous anatomical status of the heart, which is well correlated to the ECG. As shown in Fig. 1, major ECG wave forms are referred to as the P, Q, R, S, and T waves, respectively. They are electrical voltages generated by the heart and recorded from the surface of the body. The P wave is caused by the spread of depolarization through the atria, and followed by atrial contraction. Shortly after the P wave, the QRS waves appear due to depolarization of the ventricles, which initiates the ventricular contraction. Finally, the T wave indicates repolarization of the ventricles, and occurs slightly before the ventricular relaxation. To model the motion of the left ventricle mathematically, we let v f (t) represent its volume as a function of the instantaneous cardiac phase t, which can also be regarded as

1809 Wang, Zhao, and Heuscher: Dynamic volumetric cardiac imaging 1809 FIG. 1. Physiological events in the cardiac cycle. The last three curves are directly relevant, which represent the left ventricular volume, electrocardiogram, and phonocardiogram, respectively A. C. Guyton and J. E. Hall, Textbook of Medical Physiology, 9th ed. W. B. Saunders Co., Philadelphia, 1996. the percentage time in a cardiac cycle. Our basic assumption is that f (t) is a bounded, continuous, periodic function with the unit period. To simplify our model and without loss of generality, we assume that f (t) can be expressed as follows: f t f s t, for 0 t a, 1 f d t, for a t 1, for a constant 0 a 1, where f s (t) corresponds to the systole period, and f d (t) the diastole period. As it will become clear later that while a strict monotonic assumption on f s (t) and f d (t) is clinically valid and convenient for analysis, more general forms of f s (t) and f d (t) can be similarly treated. One specific model f (t), which was designed and used in our numerical simulation, is expressed in terms of the basic function 1 x 2, as shown in Fig. 2. In the figure, we divide the ECG cycle into several intervals. Let the interval 0,a 1 be the region from the peak of the R wave to the end of the S wave, where the heart is in the isovolumetric contraction FIG. 2. Idealized relationship between the cardiac status and the cardiac phase.

1810 Wang, Zhao, and Heuscher: Dynamic volumetric cardiac imaging 1810 phase with the maximum isovolume. Then, let the interval a 1,a 2 be the region from the end of the S wave roughly to the beginning of the T wave, where the heart is in the ejection phase down to the minimum isovolume. Let a 2,a 3 be from the end of the ejection phase to the end of the T wave for the isovolumetric relaxation phase. Let a 3,a 4 be from the end of the T wave to the peak of the P wave, where the heart is in the rapid inflow and diastolic phase up to a large portion of the maximum isovolume. Finally, let a 4,1 be from the peak of the P wave to the peak of the next R wave, where the heart is in the atrial systole phase, allowing f (t) reaching the maximum value then falling down. Mathematically, f (t) is expressed as follows: g t;0,1,a 1,b 1,0, 0 t a 1, t g t;a 1,b 1,a 2,b 2,a 2, a 1 t a 2, f where g t;a 2,b 2,a 3,b 3,a 2, a 2 t a 3, g t;a 3,b 3,a 4,b 4,a 4, a 3 t a 4, g t;a 4,b 4,1,1,c, a 4 t 1, g t;x 1,y 1,x 2,y 2,c 1 t c 2 x 2 x 1. 3 is the scaled and shifted version of the basic function with a symmetric axis at t c so that g(x k ) y k for k 1,2. The parameters and in the above equation depend on parameters x 1, y 1, x 2, y 2, c, and are given by y 2 x 2 c x 2 2x 1 c y 1 x 1 c x 1 2x 2 c, x 2 c x 2 2x 1 c x 1 c x 1 2x 2 c y 2 y 1 x 2 x 1 x 2 c x 2 2x 1 c x 1 c x 1 2x 2 c. How to obtain parameter values of the above motion model is important for an accurate estimation of the cardiac status. We have at least two ways to address this issue effectively. First, according to an individual ECG and based on data published by Stanford and others, 22 25 we can quite reliably infer the cardiac status within each cardiac cycle. This method may be further improved by other physical measurements, such as ultrasound images and a phonocardiogram. Second, we can actually measure the cardiac state directly from images reconstructed either assuming an idealized cardiac dynamics or using a non-ecg-gated CT algorithm, such as that developed by Taguchi and Anno. The volume-based curve is used in this paper as one illustration; other curves, such as those specific to vascular motion, could also be used to optimally image coronary vessels. In addition, knowledgebased reconstructions can be applied iteratively, e.g., our volume-gated cardiac reconstruction results can be applied to refine the volume-phase curve for an even better volumegated cardiac reconstruction. However, further iterations would require additional computing resources. Additionally, we mention that while our functional form of the cardiac 2 4 motion model is a good choice for this feasibility study, this motion model is subject to optimization in a future study. B. Data selection and interpolation First of all, we would clarify our usage of the terms phase and state as follows. By use of phase we mean the relative position in a cardiac cycle, while by use of state, or status in an abstract sense, we mean the absolute spatial configuration of the heart. The essence of our approach is to reconstruct the heart in multistates based on our knowledge about the instantaneous cardiac status, while existing algorithms reconstruct the heart in multiphases. In special cases, a state may just correspond to one cardiac phase. In the general case, as we will see later in this paper, a state may be related to two phases, when the heart is expanding and contracting, respectively. In other words, in our study we expect to reconstruct the heart in its anatomical state intervals to make the best use of projection data hence, radiation dose. Due to the geometric limitations with imaging, with each scanning turn there are only certain data segments available that are consistent to a given cardiac state interval. For ease of understanding, we first present our multistate reconstruction algorithm in the optimal case, then consider more general cases in this subsection. From now on, a cardiac state interval, or a cardiac state in brief, should be specifically understood as a left-ventricular volume interval. Without loss of generality, we assume a constant heart rate, an adjustable source scanning speed, and a circular MSCT/CBCT scanning geometry. Let us set the x-ray source rotation period to a positive rational number b m/n in the unit of the source rotation period, where m and n are relative prime integers, and b denotes the radio of the cardiac period over the source rotation period. By the strict monotonicity of both f s (t) and f d (t), we can uniquely determine n 1 volume values: v 0 v 1 v n 1 v n, where v 0 f min, v n f max, and the rest values are from n 1 intersection points v k :k 1,...,n 1 of f d (t) and n 1 functions f s (t kb), k 1,...,n 1. By doing so, there are exactly enough projection data for the reconstruction of all n cardiac states, which are collected after n source rotations within m cardiac cycles: v 0,v 1, v 1,v 2,..., v n 1,v n. Furthermore, for 1 j n, and n 1 f 1 k v j 1,v j 0, b, k 0 n 1 f 1 k v j 1,v j, k 0 where f k (t) f (t kb) for 0 t b. To visualize the above complicated relationship, we intro- 5 6 7 8

1811 Wang, Zhao, and Heuscher: Dynamic volumetric cardiac imaging 1811 FIG. 3. Cardiac motion map as a unified framework that graphically illustrates the relationship between the cardiac status, the cardiac cycle, and the projection angle. duce the concept of the cardiac motion map, as shown in Fig. 3, assuming b 8 5. This cardiac motion map is nothing but a representation of all the information contained in f (t) within only one source rotation period, or equivalently within a fullscan angular range. Because the period of the source angular range is 360, any angles outside the range of 0, 360 can be mapped into this range. In other words, the cardiac motion map is a superposition of shifted versions of f (t) within one scanning cycle, which shows the dependence between the cardiac states and the cardiac phases within the regularized full-scan angular range. It is critically important to interpret the cardiac motion map in the two ways shown in Fig. 3: 1 cycle overlapping view, and 2 data partition view. The cycle overlapping view shows the f (t) curve in only one full-scan angular range, where each full-scan segment, which corresponds to a scanning turn, is colored differently. The data partition view highlights the selection of data segments for the reconstruction of cardiac states. These states are naturally defined by v 0,v 1, v 1,v 2,..., v n 1,v n. Data segments associated with each cardiac state are colored differently. As a result, we can immediately comprehend the sufficiency and necessity of projection data for the reconstruction of any cardiac state. In reality, the period and the form of f (t) may vary significantly. As a result, the cardiac motion map may only depict a suboptimal pattern, corresponding to asymmetric/ distorted data partitions. In this case, Eqs. 7 and 8 may not hold exactly. Nevertheless, these cases can be handled in the same spirit of the cardiac motion map. Actually, for any cardiac state for example, the volume v s we can always numerically search upward and downward from the reference line of this cardiac state (v v s ) until a sufficient angular coverage is reached, which should be 180 plus two fan angles or more. Generally speaking, we prefer having a narrower cardiac state span, a less number of data segments and smoother transitions between these segments. If it is necessary, we can use a feathering technique to suppress artifacts from data discontinuities. In the MSCT situation, a special effort must be made for longitudinal data interpolation. The principle is to use data adequately close to a plane to be reconstructed. Specifically, we may request that data involved for linear/nearestneighbor interpolation be associated with x-ray paths that are within detector collimation. The greater the permissible longitudinal range for data interpolation, the better temporal resolution, but the poorer longitudinal spatial resolution. Those data that do not meet the above requirement are considered invalid. In the case of CBCT, the pitch and the angular range corresponding to a prespecified temporal resolution define the data segments for a particular cardiac state that contribute to the volume reconstruction, and the coneangle effect must be appropriately addressed. C. Knowledge-based image reconstruction Our knowledge-based MSCT/CBCT algorithm for cardiac imaging can be outlined as follows: Step 1. Obtain the relationship between the cardiac status and the cardiac phase. Step 2. Specify longitudinal locations of transverse slices to be reconstructed as well as cardiac states of interest; Step 3. Find cardiac state values v k in the cardiac motion map, where v 0 and v n are the minimum and maximum of the cardiac state, v k, (1 k n) is the solution to f d (t) f s (t kb). Step 4. Search for the angular interval: A k x:v k f x v k 1 ; 9 Step 5. For each transverse slice location z, rearrange MSCT/CBCT data g k ( ) g(x mod b) for x A k if they are close to z, then perform data interpolation; Step 6. Reconstruct each slice in the kth cardiac state from g k using an appropriate reconstruction algorithm. We propose using a filtered backprojection FB algorithm similar to a modified Feldkamp approach, e.g., that developed by Wang et al. 26 28 but adapted to cardiac cone-beam imaging.

1812 Wang, Zhao, and Heuscher: Dynamic volumetric cardiac imaging 1812 FIG. 4. Standard reconstruction and multistate reconstructions of the dynamic performance phantom. The motion artifacts are the worst with the standard reconstruction a, while they are suppressed in the multistate reconstructions c e and eliminated in b, f. III. RESULTS A. Numerical simulation 1. Dynamic performance phantom The temporal resolution can be quantified using the temporal sensitivity profile TSP, which is a temporal counter- TABLE I. Parameters of the cardiac motion model defined by Eq. 2. i 1 2 3 4 a i 0.4 0.4 0.5 0.85 b i 0.95 0.0 0.05 0.92 c i 0.1 0.1 0.85 0.95

1813 Wang, Zhao, and Heuscher: Dynamic volumetric cardiac imaging 1813 FIG. 5. Standard and multistate transaxial reconstructions of the dynamic thorax phantom, where the z index equals 64. The motion artifacts are the worst with the standard reconstruction a, while they are significantly reduced in the multistate reconstructions. part of the slice sensitivity profile SSP. To assess the temporal resolution of our proposed approach, we used a wellknown dynamic performance phantom in the literature. This dynamic performance phantom contains five sets of objects of 1000 HU, As described by Taguchi and Anno. 19 It has two sets of three cylinders of diameter 3, 2, and 1 mm, respectively. Set A is stationary while set B moves in the x direction. The phantom also contains three sets of three balls of diameter 3, 2, and 1 mm, respectively. Set C is stationary, set D moves in the y direction, and set E moves in the z direc-

1814 Wang, Zhao, and Heuscher: Dynamic volumetric cardiac imaging 1814 FIG. 6. Standard and multistate sagittal and coronal reconstruction of the dynamic thorax phantom, where the x and y indexes equal 300 and 256, respectively. The motion artifacts are the worst with the standard reconstruction a, g, while these artifacts are significantly reduced in the multistate reconstructions. tion. The cylinders are of 200 mm in length. The balls are centered at plane z 0 when they do not move. The sets B, D, and E all move at the frequency of 96 cycles per minute with the amplitude of 10 mm. The sizes, shapes, and motion patterns were chosen to simulate the cardiac and pulmonary motion in the patient. A circular CBCT geometry was simulated with 630 views and a 480 168 detector plane with height 280 mm. The source-to-center distance was set to 4000 mm. The diameter of field of view was 800 mm. A dynamic cardiac scan was simulated with five source rotations and eight cardiac cycles over the scan period. Images were constructed in 512 512 154 matrices with height 240 mm, using the standard Feldkamp algorithm. 26 Figure 4 presents a volume-rendered view of the dynamic performance phantom, which contains the standard commercial reconstruction and multistate reconstructions of the dynamic phantom. It can be observed in Fig. 4 that the motion artifacts dominate the standard reconstruction, but they are either suppressed or eliminated in the multistate reconstructions. 2. Dynamic thorax phantom To make numerical simulation more realistically, it is desirable to provide semianthropomorphic raw data of the tho- TABLE II. Measured points on the volume-phase curve in the high heart-rate case. Both the phase and the volume are in relative terms. Phase 0.0 12.5 25.0 37.5 50.0 62.5 75.0 87.5 Volume 66.8 57.3 41.9 34.1 30.8 30.8 32.1 55.2

1815 Wang, Zhao, and Heuscher: Dynamic volumetric cardiac imaging 1815 FIG. 7. Cardiac volume-phase curve in the high heart-rate case. rax. For the same purpose, a dynamic thorax phantom was developed by Sourbelle, which is published on http:// www.imp.uni-erlangen.de/forbild/english/results/index.htm. In our simulation, this phantom was chosen for its representative features and complete documentation. The phantom contains idealized major parts of the thorax, including lungs, heart, aorta, ribs, spine, sternum, and shoulders. For the initial testing, a simplified time-varying heart was created to replace the original heart in the thorax phantom. This heart consists of two ellipsoidal halves with appropriately specified parameters to simulate the shape of the heart. A cardiac motion function was defined by h t f t 2 /3, 10 where f (t) is defined by 2. The ellipsoidal heart was dynamically rescaled according to 10 with the model parameters listed in Table I. A CBCT scan was performed for b 8 5 under the same conditions as in the preceding section, except that the z coverage of the detector plane was set to 180 mm, the source-to-center distance 3000 mm, and the diameter of field of view 600 mm. The reconstructed volume is of 512 512 128 of height 150 mm. Figures 5 and 6 contain representative orthogonal sections reconstructed using the standard commercial algorithm and our knowledge-based algorithms, respectively. It can be observed that the multistate reconstructions are substantially superior to the standard reconstruction of the dynamic thorax FIG. 8. Cardiac motion map with five spiral MSCT rotations in the high heart-rate case.

1816 Wang, Zhao, and Heuscher: Dynamic volumetric cardiac imaging 1816 FIG. 9. Diagram showing a z positions of all raw projection data as well as b f selected data for reconstruction at each of the five states, respectively, where the vertical axis is for the z position table position, mm, and the horizontal axis for the projection view index, covering a full-scan angular range. phantom. Similar to what we have seen in Fig. 4, the motion artifacts are serious with the standard reconstruction, but they are significantly reduced to various degrees in the multistate reconstructions. B. Patient studies To demonstrate the feasibility and utility in clinical applications, we performed a number of patient studies using a state-of-the-art multislice CT scanner Mx8000 Philips Medical Systems, Cleveland, OH, USA. The imaging protocol requires 1 mm collimation, 4 slices, 1.25 mm table increment, 0.5 s full-scan period, and ECG recording. Both the ECG-based and image-based methods, as described in Sec. II A, were used to establish the relationship between the cardiac status and the cardiac phase. Then, appropriate data segments were selected for the reconstruction of each slice of interest in all the representative cardiac states, according to the scheme described in Sec. II B. Finally, image reconstruction was performed using the algorithm described in Sec. II C. Three comments are in order regarding the above general procedure. First, the status-phase relationship in this preliminary study takes the form of a volume-phase curve. The volume of interest at each cardiac phase was estimated from manually segmented CT images reconstructed using a halfscan algorithm. In all the cases, our cardiac motion model is

1817 Wang, Zhao, and Heuscher: Dynamic volumetric cardiac imaging 1817 FIG. 10. Standard reconstruction and multistate reconstructions of the high heart-rate patient. Each of the five states is defined according to the cardiac motion map, in terms of its percentage span in the full range of the volume variation. in excellent agreement with real data. Second, because of the spiral scanning nature and the limited number of detector rows, an adaptive closeness criterion was exercised in our data selection and interpolation. For example, when data are really needed, we relaxed the longitudinal range for the inclusion of data. Sometime the permissible interpolation ranges were even not symmetric with respect to the plane to be reconstructed to optimally match the asymmetric spiral MSCT geometry. Third, both full-scan and half-scan reconstruction options were implemented and used in our patient

1818 Wang, Zhao, and Heuscher: Dynamic volumetric cardiac imaging 1818 TABLE III. Measured points on the volume-phase curve in the low heart-rate case. Both the phase and the volume are in relative terms. Phase 0.0 12.5 25.0 37.5 50.0 62.5 75.0 87.5 Volume 162.7 161.5 123.9 76.5 80.9 118.0 128.9 146.3 studies. As expected, the half-scan reconstruction option was instrumental when full-scan data are unavailable. In the following, we only present two typical examples, which are high heart-rate and low heart-rate cases, respectively. 1. High heart-rate case The heart rate in this case is quite constant, about 98 beats per minute bpm. As a result, the ratio b between the cardiac period and the full-scan period is about 1.22, which is close FIG. 11. Cardiac volume-phase curve in the low heart-rate case. FIG. 12. Cardiac motion map with five spiral MSCT rotations in the low heart-rate case.

1819 Wang, Zhao, and Heuscher: Dynamic volumetric cardiac imaging 1819 FIG. 13. Diagram showing a z positions of all raw projection data as well as b f selected data for the reconstruction at each of the five states, respectively, where the vertical axis is for the z position table position, mm, and the horizontal axis for projection view index, covering a full-scan angular range. to b 5 4, allowing reconstruction of 5 states. Eight data points of the volume-phase curve were determined by segmenting images reconstructed using a half-scan algorithm. These data are summarized in Table II. Then, we conducted cubic-spline fitting to generate a smooth volume-phase curve, as shown in Fig. 7. To use this information for dynamic reconstruction, the spline fitted curve was periodically extended. The cardiac motion map in this case reveals the realistic overlapping patterns of the cardiac cycles and the feasible data partitions for each of the five cardiac state, as shown in Fig. 8. Note that in the real case the cardiac motion map is indeed suboptimal, a numerical search was done to complete the data partition work according to the motion map, as we discussed in Sec. II B, Data selection and interpolation. Figure 9 plots the z-position distributions of the selected data for dynamic reconstruction of the five states. Figure 10 includes a set of images reconstructed using the standard algorithm and our algorithm, respectively. It can be easily observed that our state-based reconstructions are definitely superior to the standard commercial reconstruction, because the cardiac boundaries are much better defined in all the five states. Here we would like to emphasize the cardiac volume, while optimal reconstruction of the coronary vessels can be achieved using a vessel-position-based approach, essentially similar to our volume-based approach. 2. Low heart-rate case The low heart-rate case was similarly studied as in the high heart-rate case. The heart-rate in this case varies sub-

1820 Wang, Zhao, and Heuscher: Dynamic volumetric cardiac imaging 1820 FIG. 14. Standard reconstruction and multistate reconstructions of the low heart-rate patient. Each of the five states is defined according to the cardiac motion map, in terms of its percentage span in the full range of the volume variation. stantially, from 50 60 bpm. Since the source rotation period was fixed at 0.5 s, the data associated with about 60 bpm allow reconstruction of only 2 independent states. To reconstruct more states, those data segments that are associated with about 51 bpm were selected for b 2.32. Eight data points of the volume-phase curve were determined by segmenting images reconstructed using a half-scan algorithm. These data are summarized in Table III. Figure 11 is the cubic-spline representation of the data in Table III. Figure 12 includes two interpretations of the cardiac motion

1821 Wang, Zhao, and Heuscher: Dynamic volumetric cardiac imaging 1821 map in this case. As shown in Figs. 13 and 14, in this low heart-rate case the multistate reconstructions were not done at the same z level, that is, states 3 and 5 were reconstructed at levels slightly different from that for states 1, 2, and 4, because the cardiac motion and the source scanning were not well synchronized to give sufficient data. However, we emphasize that even in the difficult case of this type the reconstructions were indeed of multistates with significantly better image quality of ventricular sections than the standard commercial reconstruction. IV. DISCUSSION AND CONCLUSION The estimation and utilization of the cardiac status-phase relationship is the key for success of our knowledge-based cardiac imaging approach. Although we have focused on the volume as the primary indicator of the cardiac status, the space of the cardiac status is evidently multidimensional. How to optimally and realistically capture the cardiac status in relation to the cardiac cycle remains an exciting topic. Our insight suggests that the most promising strategy should be toward a synergistic combination of an electronic atlas of the dynamic cardiac anatomy, various measurements of anatomical/physiological signals, as well as abundant information from raw projection data. As a powerful tool, the cardiac motion map can be extended to represent projection data in suboptimal and even difficult cases. With a user-friendly design, additional information can be integrated into the cardiac motion map. For example, permissible data segments may be indicated using characteristic curve segments. Also, the completeness of the permissible data can be computed and visualized in a sinogram derived from the cardiac motion map. We believe that our approach should be useful in other cardiac imaging modalities as well, MRI in particular. Much work is needed to optimize the imaging strategy for our knowledge-based cardiac imaging approach. Intrinsic interactions exist among imaging parameters, between temporal resolution and longitudinal spatial resolution, between spatial resolution and contrast resolution, between resolution and artifacts, as well as their dependencies on interpolation/ reconstruction details. 29 32 The optimality should also depend on features of interest or diseases of concern. Given the complexity of this problem, each imaging aspect needs to be addressed appropriately before the reconstruction quality of the cardiac anatomy can be optimized. Special attention should be paid when our knowledgebased cardiac imaging approach is applied to cone-beam geometry. Although the essential idea is the same as in the multislice geometry, the intermediate or large cone angle must be rigorously compensated for to suppress image artifacts, which may be more distracting in the dynamic imaging situation than in the static counterpart. The longitudinal data truncation and the spiral scanning pattern makes the cardiac imaging even more complicated. However, because we can now utilize more specific knowledge on the cardiac dynamics, our approach is already in a better position to produce superior images than existing cardiac imaging algorithms. We are currently addressing this problem with a modified FB approach, which will be reported in a follow-up publication. In conclusion, we have developed a knowledge-based spiral/helical multislice/cone-beam CT approach for dynamic volumetric cardiac imaging. For the first time, we have made available a methodology to tap into the geometric knowledge on the cardiac status. Even in our preliminary numerical simulation and patient studies, the knowledge-based cardiac CT algorithm has improved image quality greatly. This approach should bring immediate benefits for cardiac CT screening and diagnosis, and have a great potential in view of the rapid development of MSCT/CBCT technology. We are actively working on further development of this knowledge-based cardiac imaging approach, as well as the rigorous evaluation of diagnostic performance improvement. ACKNOWLEDGMENTS This work was supported in part by grants from the Philips Medical Systems, the National Institutes of Health DC03590, HL64368, and the Whitaker Foundation RG- 98-0448. The authors thank Dr. William Stanford, Dr. Honchi Lee, Dr. Simon Kao, Dr. Melhem Sharafuddin, and Dr. Michael Vannier for helpful discussions, who are with the University of Iowa, as well as Dave Matthews, Mani Vembar, and Kevin Brown for technical advice and data processing, who are with Philips Medical Systems, and Dr. Yun Liang with Purdue University for help with datasets. a Electronic mail: gc-wang@uiowa.edu 1 B. Ohnesorge, T. Flohr, C. Becker, A. F. Kopp, U. J. Schoepf, U. Baum, A. Knez, K. Klingenbeck-Regn, and M. F. Reiser, Cardiac imaging by means of electrocardiographically gated multisection spiral CT: initial experience, Radiology 217, 564 571 2000. 2 D. P. Boyd and M. J. Lipton, Cardiac computed tomography, Proc. IEEE 71, 198 307 1983. 3 K. Taguchi and H. Aradate, Algorithm for image reconstruction in multi-slice helical CT, Med. Phys. 25, 550 561 1998. 4 H. Hu, Multi-slice helical CT: scan and reconstruction, Med. Phys. 26, 5 18 1999. 5 G. Wang, C. R. Crawford CR, and W. A. Kalender, Multi-row-detector and cone-beam spiral/helical CT, IEEE Trans. Med. Imaging 19, 817 821 2000. 6 C. C. Morehouse, W. R. Brody, D. F. Guthaner, R. S. Breiman, and G. S. Harell, Gated cardiac computed tomography with a motion phantom, Radiology 134, 134 137 1980. 7 P. M. Joseph and J. Whitley, Experimental simulation evaluation of ECG-gated heart scans with a small number of views, Med. Phys. 10, 444 449 1983. 8 G. H. Glover, N. J. Pelc, and J. R. MacFall, Method for acquiring nmr data which is subject to periodic variations, United States Patent 4,751,462, 1987. 9 C. R. Crawford and N. J. Pelc, Method for reduction motion induced artifacts in projection imaging, United States Patent 4,994,965, 1991. 10 G. H. Glover and N. J. Pelc, Apparatus and method for evenly distributing events over a periodic phenomenon, United States Patent 4,720,678, 1988. 11 C. J. Ritchie, C. R. Crawford, J. D. Godwin, and Y. Kim, Correction of respiratory motion artifacts in CT with pixel-specific backprojection, Radiology 185, 271 1992. 12 C. J. Ritchie, C. R. Crawford, J. D. Godwin, K. F. King, and Y. Kim, Correction of computed tomography motion artifacts using pixelspecific back-projection, IEEE Trans. Med. Imaging 15, 333 342 1996.

1822 Wang, Zhao, and Heuscher: Dynamic volumetric cardiac imaging 1822 13 G. Wang and M. W. Vannier, Preliminary study on helical CT algorithms for patient motion estimation and compensation, IEEE Trans. Med. Imaging 14, 205 211 1995. 14 N. P. Willis and Y. Bresler, Optimal scan for time-varying tomography I: Theoretical analysis and fundamental limitations, IEEE Trans. Image Process. 5, 642 653 1995. 15 N. P. Willis and Y. Bresler, Optimal scan for time-varying tomography II: Efficient design and experimental validation, IEEE Trans. Image Process. 5, 654 666 1995. 16 D. J. Heuscher, Dynamic volume scanning for ct scanners, United States Patent 5,262,946, 1993. 17 D. J. Heuscher, W. W. Lindstrom, and H. K. Tuy, Multiple detector ring spiral scanner with relatively adjustable helical paths, United States Patent 5,485,492, 1996. 18 D. J. Heuscher, S. Chandra, R. Shekhar, and D. Hoffmeyer, Cardiac ct system, United States Patent 6,154,516, 2000. 19 K. Taguchi and H. Anno, High temporal resolution for multislice helical computed tomography, Med. Phys. 27, 861 872 2000. 20 M. Kachelriess and W. A. Kalender, ECG-correlated image reconstruction from subsecond spiral computed tomography scans of the heart, Med. Phys. 25, 2417 2431 1998. 21 M. Kachelriess, S. Ulzheimer, and W. A. Kalender, ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart, Med. Phys. 27, 1881 1902 2000. 22 Z. D. Hajduczok, R. M. Weiss, W. Stanford, and M. L. Marcus, Determination of right ventricular mass in humans and dogs with ultrafast cardiac computed tomography, Circulation 82, 202 212 1990. 23 B. H. Thompson and W. Stanford, Evaluation of cardiac function with ultrafast computed tomography, Radiol. Clin. North Am. 32, 357 551 1994. 24 M. Grover-McKay, R. M. Weiss, B. F. Vandenberg, T. L. Burns, J. Wiedner, M. D. Winniford, W. Stanford, and C. R. McKay, Assessment of cardiac volumes and left ventricular mass by cine computed tomography before and after mitral balloon commissurotomy, Am. Heart J. 128, 533 539 1994. 25 W. Stanford and B. H. Thompson, Cornary atherosclerosis and its effect on cardiac structure and function: Evaluation by electron beam computed tomography, Clin. Chem. 44, 1871 1881 1998. 26 L. A. Feldkamp, L. C. Davis, and J. W. Kress, Practical cone-beam algorithm, J. Opt. Soc. Am. 1, 612 619 1984. 27 G. Wang, T. H. Lin, P. C. Cheng, and D. M. Shinozaki, A general cone-beam reconstruction algorithm, IEEE Trans. Med. Imaging 12, 486 496 1993. 28 G. Wang, Y. Liu, T. H. Lin, and P. C. Cheng, Half-scan cone-beam x-ray microtomography formula, J. Scanning Microsc. 16, 216 220 1994. 29 A. C. Kak and M. Slaney, Principles of Computerized Tomographic Imaging IEEE Press, New York, 1987. 30 F. Natterer, The Mathematics of Computerized Tomography Wiley, New York, 1986. 31 G. Wang and M. W. Vannier, The effect of pitch in multi-slice spiral/ helical CT, Med. Phys. 26, 2648 2653 1999. 32 G. Wang and M. W. Vannier, Computerized tomography, in Encyclopedia of Electrical and Electronics Engineering, edited by J. G. Webster Wiley, New York, 1999, Vol. 4, pp. 8 24.