The Evolution of Fundus Perimetry

Similar documents
The New Frontier of Microperimetry

The New Frontier of Microperimetry

The ideal tool for early detection and monitoring of AMD.

Macular Integrity Assessment. Microperimetry Handbook. First Edition

EasyScan: Smart Retinal Imaging

NEW AUTOMATED PERIMETERS NEW. Fast and precise perimetry at your fingertips. ZETA strategy EyeSee recording DPA analysis

3/16/2018. Perimetry

C a t a r a c t G l a u c o m a R e t i n a R e f r a c t i v e. The GDxVCC Early answers and ongoing assessment for glaucoma

PRIMUS 200 from ZEISS The essential OCT

The MP-1 Microperimeter Clinical Applications in Retinal Pathologies

STRUCTURE & FUNCTION An Integrated Approach for the Detection and Follow-up of Glaucoma. Module 3a GDx

Experience Spectacular Retinal Imaging with the new NIDEK F-10 Digital Ophthalmoscope

Hidden LED Array Perimeter IVS-201A / IVS-201B. Reliable Accurate Economical. Lis t ic

PRIMUS 200 from ZEISS The essential OCT

EVALUATION OF FIXATION DURING PERIMETRY USING A NEW FUNDUS PERIMETER

Definitions. Indications for Perimetry. Indications for Perimetry. Purposes of Perimetry. Indications for Perimetry 3/4/2015

Supplementary Appendix

Visual Fields Shawn L. Cohen, M.D. Part 2 of 4. Definitions / Tables (Part 2 of 2) Static Perimetry (Humphrey, Octopus)

Moving forward with a different perspective

21st Century Visual Field Testing

Macular Integrity Assessment. Microperimetry Handbook. First Edition

Cirrus TM HD-OCT. Details defi ne your decisions

Investigative Ophthalmology & Vision Sciences MSc Course. Glaucoma Module. Visual Field Reliability Indices. David Henson 2014.

Cirrus TM HD-OCT. Details define your decisions

Glaucoma: Diagnostic Modalities

VISUAL FIELDS. Visual Fields. Getting the Terminology Sorted Out 7/27/2018. Speaker: Michael Patrick Coleman, COT & ABOC

Science & Technologies

The Effect of Pupil Dilation on Scanning Laser Polarimetry With Variable Corneal Compensation

The Measure of Confidence

Non-commercial use only

SOCT Copernicus REVO. * - Currently import and overlay are avaibale in manual mode only

Macular pseudoholes (MPHs) are well-demarcated, DEVELOPMENT OF MACULAR PSEUDOHOLES. A 36-Month Period of Follow-up

The Role of the RNFL in the Diagnosis of Glaucoma

STANDARD AUTOMATED PERIMETRY IS A GENERALLY

Expanding your field of vision. Visual Field Analyzers from Carl Zeiss

INTERCHANGEABLE HEAD SYSTEM. Easily and quickly change between caries diagnosis and intraoral imaging. T r i t o n H D

Widefield Retinal Imaging with Auto Fluorescence Technology in the Optometric Practice

GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER. Setting The Clinical Standard

Yasser R. Serag, MD Tamer Wasfi, MD El- Saied El-Dessoukey, MD Magdi S. Moussa, MD Anselm Kampik, MD

Five Things You re Missing with Your Fundus Camera

Linking structure and function in glaucoma

The World s fastest OCT. As simple as pressing. the start button

CHAPTER 10 NON-CONVENTIONAL PERIMETRY

TUMBLING E RESOLUTION PERIMETRY IN GLAUCOMA

OCT in the Diagnosis and Follow-up of Glaucoma

OCT Image Analysis System for Grading and Diagnosis of Retinal Diseases and its Integration in i-hospital

Summary HTA HTA-Report Summary Validity and cost-effectiveness of methods for screening of primary open angle glau- coma

Evolving glaucoma management True diagnostic integration for the preservation of vision

Specific deficits of flicker sensitivity in glaucoma and ocular hypertension

Structural examina.on: Imaging

Navigated Laser Therapy. A New Era in Retinal Disease Management

Correlation of Blue Chromatic Macular Sensitivity with Optic Disc Change in Early Glaucoma Patients

NERVE FIBER LAYER THICKNESS IN NORMALS AND GLAUCOMA PATIENTS

Method for comparing visual field defects to local RNFL and RGC damage seen on frequency domain OCT in patients with glaucoma.

CHAPTER 13 CLINICAL CASES INTRODUCTION

Financial Disclosure. Visual Field Interpretation RELIABILITY VISUAL FIELD INTERPRETATION IN GLAUCOMA METHODS OF DATA PRESENTATION

Noel de Jesus Atienza, MD, MSc and Joseph Anthony Tumbocon, MD

Fluctuations on the Humphrey and Octopus Perimeters

Eye-tracking technology in low vision: implications for functional diagnosis and rehabilitation

Scanning Laser Polarimetry in Patients with Acute Attack of Primary Angle Closure

DRI OCT Triton Series A Multimodal Swept Source OCT

Perimetric testing is used clinically to detect visual field

Introducing ANGIOVUE ESSENTIAL. Built on the Avanti Widefield OCT Platform. OCT Angiography for Primary Eye Care

tracking progression we can better manage our patients. Like any tool, any instrument you ve got to

Use of Scanning Laser Ophthalmoscope Microperimetry in Clinically Significant Macular Edema in Type 2 Diabetes Mellitus

PLEX Elite 9000 from ZEISS Swept-Source OCT

3/23/2016. Diagnostic Services Taylor Pannell CRA, OCT-C. Services Available. Important info for the Tech to know. Visual Fields

On Different Wavelengths: The Spectrum of Retinal Imaging. On Different Wavelengths: The Spectrum of Retinal Imaging. Wavelength Specific Imaging

RETINAL NERVE FIBER LAYER

The only measure of RNFL Integrity: GDxPRO

CHAPTER 11 KINETIC PERIMETRY WHAT IS KINETIC PERIMETRY? LIMITATIONS OF STATIC PERIMETRY LOW SPATIAL RESOLUTION

Comparative study of new imaging technologies for the diagnosis of glaucoma: Protocol Approved by the Ethics Committee

CS Introducing the CS 1600 Intraoral Camera Revolutionary technology. Superior workflow.

The only measure of RNFL Integrity : GDxPRO

CS Introducing the CS 1600 Intraoral Camera Revolutionary caries detection aid. FIRE technology. Superior patient care.

Parafoveal Scanning Laser Polarimetry for Early Glaucoma Detection

Comparative evaluation of time domain and spectral domain optical coherence tomography in retinal nerve fiber layer thickness measurements

Intro to Glaucoma/2006

PERIMETRY A STANDARD TEST IN OPHTHALMOLOGY

Extraction of Blood Vessels and Recognition of Bifurcation Points in Retinal Fundus Image

BC380. The New Standard in Body Composition Analysis BODY COMPOSITION ANALYZER

Goals. Glaucoma PARA PEARL TO DO. Vision Loss with Glaucoma

Translating data and measurements from stratus to cirrus OCT in glaucoma patients and healthy subjects

Tips and Tactics for Retinal Imaging

DC-6. Diagnostic Ultrasound System

Lasers and Imaging PHOTOCOAGULATION PHOTODISRUPTION SLT PHOTOREGENERATION DIAGNOSTIC ULTRASOUND

VPAT Summary. VPAT Details. Section Telecommunications Products - Detail. Date: October 8, 2014 Name of Product: BladeCenter HS23

Correlating Structure With Function in End-Stage Glaucoma

USER'S MANUAL. METROVISION - 4 rue des Platanes PERENCHIES FRANCE

Oishi A, Miyamoto K, Yoshimura N. Etiology of carotid cavernous fistula in Japanese. Jpn J Ophthalmol. 2009;53:40-43.

Visualize. Analyze. Personalize. OCT + OCTA. with

S Morishita, T Tanabe, S Yu, M Hangai, T Ojima, H Aikawa, N Yoshimura. Clinical science

Xperius Ultrasound System Responsive Advanced Simple

Seiji T. Takagi, Yoshiyuki Kita, Asuka Takeyama, and Goji Tomita. 1. Introduction. 2. Subjects and Methods

MOVE IT OR LOSE IT: THE ROLE OF KINETIC VISUAL FIELDS

Clinical Trial Endpoints for Macular Diseases

Analysis of the Retinal Nerve Fiber Layer Texture Related to the Thickness Measured by Optical Coherence Tomography

Make a more confident glaucoma risk assessment with Corneal Hysteresis, a superior predictor of glaucoma progression.

Visual Deficits in Amblyopia

Behandlungsstrategien beim Offenwinkelglaukom. F. Bochmann, Augenklinik LUKS

Transcription:

The Evolution of Fundus Perimetry

Company Profile CenterVue designs and manufactures highly automated medical devices for the diagnosis and management of ocular pathologies, including those that represent the leading causes of blindness. Our goal is to design Smartly Simple devices and to provide high-value services that enable Eye Care Specialists to better preserve patients sight and quality of vision, in particular by detecting preventable diseases; and in so doing dramatically improve their quality of life. CenterVue is headquartered in Padova, Italy, with the US branch in San Jose, California. CenterVue is present in over 70 countries with its distribution network. 2 Fundus Perimetry 3

It seems evident that the main usage for microperimeters is destined to monitor glaucoma damaged residual functional vision [..] For mainstream ophthalmology many indicators point to the fact that microperimeters may take the lead role played by SAP in the last decades. Microperimetry and clinical practice: an evidence-based review; Samuel N. Markowitz, MD, FRCSC, Sophia V. Reyes, MD. Canadian Journal of Ophthalmology Vol. 48, Issue 5. 4 Fundus Perimetry 5

Fundus related perimetry Introducing COMPASS Fundus related perimetry is a technique that images the retina during visual field testing, enabling a correlation to be made between visual function and retinal structure. 1 Advantages of Fundus Perimetry 2 over Standard Automated Perimetry include reduced test retest variability, increased sensitivity to early deficits, the possibility to measure sensitivity at specific retinal locations, higher accuracy in the description of scotomas and of course the simultaneous assessment of function (expressed by retinal sensitivity) and structure (images of the ONH and of the retina). Fundus Perimetry also provides a simultaneous, quantitative assessment of fixation characteristics. The first fundus perimeter capable of performing standard 24-2 visual field testing and the first confocal system delivering true color images. COMPASS is a scanning ophthalmoscope combined with an automatic perimeter that provides confocal images of the retina, as well as measurements of retinal threshold sensitivity, under non-mydriatic conditions. 32 33 32 34 33 33 34 32 31 32 32 30 31 39 32 31 33 31 29 28 26 29 28 32 10 33 33 39 28 32 31 29 27 32 32 38 32 39 28 31 33 38 29 31 33 33 33 38 38 33 28 38 31 32 32 33 31 31 31 31 32 31 34 32 30 32 31 38 38 Example of 10-2 Fundus Perimetry Example of 10-2 SAP Use of Fundus Perimetry in the clinical management of glaucoma has been limited so far, as available systems were lacking compliance with the standards of automated perimetry. COMPASS overcomes such limitations and brings visual field analysis to the next level! In particular COMPASS, for the first time, extends field coverage to 30 + 30 and employs luminance parameters and a sensitivity scale as used in standard automated perimetry. 1 Crossland et al., 2012 2 Also referred as microperimetry 6 Fundus Perimetry 7

The Next Level of Fundus Perimetry Retinal Tracking Compatibility with standard 24-2 visual field testing As a perimeter, the system offers full compatibility with standard 24-2 visual field testing and contains an age-matched database of retinal sensitivity in normal subjects. Retinal tracking is at the heart of Fundus Perimetry. Infrared images, acquired at the rate of 25 images per second, allow for continuous, automated, tracking of eye movements, with positional accuracy in the 10-20 microns range. Determination of eye movements yields to Fixation Analysis, where the location of the functional site of fixation and its stability are computed. Fixation analysis is unique to Fundus Perimetry. Retinal tracking also yields to active compensation of fixation losses, with perimetric stimuli being automatically re-positioned prior to projection based on the current eye position. This mechanism is critical to reduce test-retest variability and ensure accurate correlation between function (i.e. retinal threshold values) and structure (retinal appearance). 24-2 test performed with Compass Compensation of eye movements takes place before and during the projection of a certain stimulus. In absence of this mechanism, a normal 2-3 degrees shift in eye position occurring at the time of projection of a certain stimulus would easily produce an artifact in VF results, with a wrong sensitivity being reported at that specific location. Plot of eye movements during VF testing 3 Superior quality of color and red-free images As a retinal imager, COMPASS uses a confocal optical design, similarly to SLO systems, to capture color as well as red-free images of superior quality. In addition, a high resolution live image of the retina obtained using infrared illumination is available throughout the test. Color image: detail of the ONH Color confocal imaging SLO systems are superior to conventional fundus cameras in many ways, as they exploit a confocal imaging principle, which limits the effect of backscattered light from deeper layers and provides enhanced image quality in terms of contrast and resolution. Another major advantage of SLO systems is that they operate with much smaller pupils than non-confocal instruments. At the same time, though, SLO systems do not provide color images, as they typically employ monochromatic laser sources, resulting in black and white or pseudo-color images. Differently from existing SLO systems, Compass uses white light instead of monochromatic lasers, hence providing true color images and offering high fidelity to real retinal appearance. Compass images improve the diagnostic capabilities in the management of glaucoma as they offer: Color image: detail of the ONH no need for pupil dilation excellent resolution and contrast high quality even in presence of media opacities, such as cataract optimized exposure of the ONH Infrared image Red-free image: detail of the RNFL Non-confocal imaging: detail of the ONH 8 Fundus Perimetry 9

Fixation Analysis In Glaucoma How to Read Printouts Studies have demonstrated abnormal fixation characteristics in patients diagnosed with early Primary Open Angle Glaucoma (POAG) and Advanced Glaucoma without other retinal diseases. COMPASS combines in one page the standard deviation maps typical of SAP with structure-function correlation data as well as fixation analysis. For example, fixation instability has been demonstrated in early and moderate POAG [1], while other studies have reported predominantly eccentric fixation in up to 15% of the studied population with advanced glaucoma [2]. Finally, it is known that fixation stability and its location correlate with visual acuity, in particular the more unstable and eccentric fixation is, the lower visual acuity [3]. Legend 1 Patient info 2 Examined eye 4 1 5 3 2 Fixation analysis with Compass provides additional, quantitative, parameters for assessing visual function. 3 Exam info 4 Color image of ONH 1. Shi Y, Liu M, Wang X, Zhang C, Huang P (2013) Fixation behavior in primary open angle glaucoma at early and moderate stage assessed by the MicroPerimeter MP-1. Journal of glaucoma 22 (2):169-173. 2. Kameda T, Tanabe T, Hangai M, Ojima T, Aikawa H, Yoshimura N (2009) Fixation behavior in advanced stage glaucoma assessed by the MicroPerimeter MP-1. Japanese journal of ophthalmology 53 (6):580-587. 3. Morales MU, Saker S, Mehta RL, Rubinstein M, Amoaku WM (2013) Preferred retinal locus profile during prolonged fixation attempts. Can J Ophthalmol 48 (5):368-374. 5 Fundus Perimetry (db) over red-free image 6 Deviation maps 7 Standard VF map 6 7 Benefits Features 8 Mean Deviation and Pattern Standard Deviation High-resolution confocal imaging of the ONH and of the central retina Combined structure and function analysis Significantly reduced test retest variability Reliable follow-up Fully automated operation Comprehensive and clear printout Operator friendly More patient comfort: test can be suspended at any time without data loss Pupillary tracking Fixation control using automated highresolution, 25 Hz, retinal tracking Auto-focus Fully automated, visual field testing (24-2, 10-2, custom) Automatic follow-up Confocal, 60 imaging Color, red-free, infrared imaging Patient vocal guidance during VF testing Quantitative analysis of Fixation 9 10 11 Glaucoma Staging System 2 Bivariate Contour Ellipse Area indices and fixation plot over IR image Fixation graph describing amplitude of eye movements vs. time 9 8 10 11 Wired/WiFi connectivity Touch-screen operated via tablet Non-mydriatic operation 10 Fundus Perimetry 11

Technical specifications * The smartly simple approach COMPASS performs the entire 24-2 test, including capture of infrared, red-free and color retinal images, in a fully automatic way. Class and type of applied part 1, B (according to EN 60601-1). Fundus Perimetry: Projection field: 30 (radius) Background luminance: 31.4 asb Maximum luminance: 10000 asb Dynamic range: 0-50 db Stimulus size: Goldmann III (26 ), V Stimulus duration: 200 ms Threshold tests: 24-2, 30-2, 10-2, custom Fixation control: 25 Hz automated retinal tracking Foveal threshold testing Automatic pupil measurement Fundus Imaging: Fixation target: programmable, internal User interface: Nexus Tablet with 10.1 multi-touch screen Connectivity: Wi-Fi and Ethernet Printer: any printer compatible with Tablet Hard drive: 250 GB Dimensions: Weight: 25 Kg Size: H 620 X W 590 X D 360 mm Electrical requirements: Power: 100-240 VAC, 50-60 Hz Consumption: 80 W The complete process includes: automated alignment of the instrument to the patient, using bilateral pupil tracking; auto-focus, correcting for the patient s spherical refraction; automated acquisition of live, infrared, retinal images; automated execution of the VF test; automated collection of fixation data throughout the VF test; automated compensation of eye movements during VF testing, using retina and pupil tracking; automated acquisition of a color retinal image, including auto-exposure; the only intervention by the operator during the process is the selection of the center of the ONH. Field of view: 60 (diameter) Sensor resolution: 5 Mpixel (2592x1944) Light source: infrared (825-870 nm) and white LED (440-650 nm) Imaging modalities: color, infrared, red-free Resolution: 14 microns Other features: Automatic operation: auto-alignment, autofocus, auto-retinal tracking, auto-pupil tracking, auto-exposure, auto-capture Non-mydriatic operation: minimum pupil size 3 mm Working distance: 28 mm Auto-focus range: -12D to +15D Ergonomic and motorized chin rest. Improved cleaning ability of the patient rest cushions. Touch screen interface and high resolution, 2560x1600 pixel display. The patient push button is designed for improved ergonomics. Connectors on the back include 3 USB ports and 1 Ethernet port. Digital joystick is used for manual alignment and focusing. * Specifications are subject to change without notice for improvement. 12 Fundus Perimetry 13

The first fundus perimeter capable of performing standard 24-2 visual field testing and delivering true color confocal images. 14 Fundus Perimetry 15

adimer.net Centervue SpA Via San Marco 9H 35129 Padova - Italy Ph: +39 049 7396 147 Fax +39 049 7396 148 info@centervue.com www.centervue.com Centervue Inc. 92 Bonaventura Drive, San Jose CA 95134 - USA Ph: +1 408 988 8404 Fax: +1 408 716 3271 infous@centervue.com www.centervue.com REV01-140905