Studies with electron beam computed tomography (EBCT) Imaging

Similar documents
Improvement of Image Quality with ß-Blocker Premedication on ECG-Gated 16-MDCT Coronary Angiography

Coronary CT Angiography

Chapter 4. Department of Cardiology, Leiden University Medical Center, Leiden, The Netherlands. Department of Radiology,

M Marwan, D Ropers, T Pflederer, W G Daniel, S Achenbach

ECG-Gated 16-MDCT of the Coronary Arteries: Assessment of Image Quality and Accuracy in Detecting Stenoses

The diagnostic evaluation of dual-source CT (DSCT) in the diagnosis of coronary artery stenoses

Image quality and diagnostic accuracy of 16-slice multidetector computed tomography for the detection of coronary artery disease in obese patients

Angio-CT: heart and coronary arteries

Improved Noninvasive Assessment of Coronary Artery Bypass Grafts With 64-Slice Computed Tomographic Angiography in an Unselected Patient Population

Coronary Artery Imaging. Suvipaporn Siripornpitak, MD Inter-hospital Conference : Rajavithi Hospital

Diagnostic Accuracy of Noninvasive Coronary Angiography Using 64-Slice Spiral Computed Tomography

Non-invasive intravenous coronary angiography using electron beam tomography and multislice computed tomography

Improving Diagnostic Accuracy of MDCT Coronary Angiography in Patients with Mild Heart Rhythm Irregularities Using ECG Editing

Optimal image reconstruction intervals for non-invasive coronary angiography with 64-slice CT

Diagnostic accuracy of dual-source computed tomography in the detection of coronary chronic total occlusion: Comparison with invasive angiography

Journal of the American College of Cardiology Vol. 47, No. 8, by the American College of Cardiology Foundation ISSN /06/$32.

TITLE: Multi-Slice Computed Tomography Coronary Angiography for Coronary Artery Disease: A Review of the Clinical Effectiveness and Guidelines

Impact of SSF on diagnostic performance of coronary CT angiography within one heart beat in patients with high heart rate using a 256-row detector CT

Fundamentals, Techniques, Pitfalls, and Limitations of MDCT Interpretation and Measurement

Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control

Non-invasive coronary angiography with high resolution multidetector-row computed tomography

Coronary Artery Disease - Reporting and Data System (CAD-RADS)

Zurich Open Repository and Archive

2004;77:800 4 MSCT OF CORONARY ARTERY BYPASS GRAFTS. Results. CABG With Adequate Diagnostic Quality

X-ray coronary angiography is considered the diagnostic

Non-invasive Coronary Angiography: the Role, Limitations and Future of 64-Slice Spiral Computed Tomography Coronary Angiography

IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 51, NO. 1, FEBRUARY

Low-dose CT coronary angiography in the step-andshoot mode: diagnostic performance

Calcium scoring using 64-slice MDCT, dual source CT and EBT: a comparative phantom study

Adapted Transfer Function Design for Coronary Artery Evaluation

Eur Heart J. 2011;32:637-45

Accuracy of Multislice Computed Tomography in the Preoperative Assessment of Coronary Disease in Patients With Aortic Valve Stenosis

Dr Felix Keng. Imaging of the heart is technically difficult because: Role of Cardiac MSCT. Current: Cardiac Motion Respiratory Motion

Department of Cardiology, Grosshadern Clinic, University of Munich, Marchioninistrasse 15, Munich, Germany. Department of Cardiology,

Sang Ho Lee, Byoung Wook Choi, Hee-Joung Kim*, Member, IEEE, Haijo Jung, Hye-Kyung Son, Won-Suk Kang, Sun Kook Yoo, Kyu Ok Choe, Hyung Sik Yoo

Spiral Multislice Computed Tomography Coronary Angiography: A Current Status Report

Cardiac computed tomography: indications, applications, limitations, and training requirements

What every radiologist should know about cardiac CT: A case-based pictorial review

The Final 10-Year Follow-up Results from the Bari Randomized Trial J Am Coll Cardiol (2007) 49;1600-6

Diagnostic Accuracy of Multidetector Computed Tomography Coronary Angiography in Patients With Dilated Cardiomyopathy

Multidetector-row cardiac CT: diagnostic value of calcium scoring and CT coronary angiography in patients with symptomatic, but atypical, chest pain

Diagnostic Accuracy of Angiographic View Image for the Detection of Coronary Artery Stenoses by 64-Detector Row CT

Electron Beam CT versus 16-slice Spiral CT: How Accurately Can We Measure. Coronary Artery Calcium Volume?

Characteristics of Subclinical Coronary Artery Disease in Diabetic Patients without Known Coronary Artery Disease

RAMA-EGAT Risk Score for Predicting Coronary Artery Disease Evaluated by 64- Slice CT Angiography

Diagnostic and Prognostic Value of Coronary Ca Score

Diagnostic Accuracy of Computed Tomography Angiography in Patients After Bypass Grafting

Is computed tomography angiography really useful in. of coronary artery disease?

Ultrasound. Computed tomography. Case studies. Utility of IQon Spectral CT in. cardiac imaging

Multidetector Computed Tomography (MDCT) in Coronary Surgery: First Experiences With a New Tool for Diagnosis of Coronary Artery Disease

Cardiac CT imaging in coronary artery disease: Current status and future directions

Feasibility and Accuracy of 64 Row MDCT Coronary Imaging from a Centre with Early Experience: A Review and Comparison with Established Centres

Soft and Intermediate Plaques in Coronary Arteries: How Accurately Can We Measure CT Attenuation Using 64-MDCT?

Coronary angiography is the standard way of visualizing

Chapter. Non-Invasive Coronary Imaging and Assessment of Left Ventricular Function using 16-slice Computed Tomography

Correlation of Cardiac CTA to Conventional Cardiac Angiography in Diagnosing Coronary Artery Stenosis in a Community Based Center

Effect of dose reduction on image quality and diagnostic performance in coronary computed tomography angiography

Calcium scoring Clinical and prognostic value

Cardiac CT - Coronary Calcium Basics Workshop II (Basic)

Non-invasive Plaque Imaging

Coronary revascularization treatment based on dual-source computed tomography

Perspectives of new imaging techniques for patients with known or suspected coronary artery disease

SYMPOSIA. Coronary CTA. Indications, Patient Selection, and Clinical Implications

Coronary Calcium Screening Using Low-Dose Lung Cancer Screening: Effectiveness of MDCT with Retrospective Reconstruction

Assessment of Non-Calcified Coronary Plaques Using 64-Slice Computed Tomography: Comparison With Intravascular Ultrasound

Noninvasive Coronary Imaging: Plaque Imaging by MDCT

THE ROLE OF HIGH END MULTI DETECTOR CT IN CORONARY IMAGING ESSAY

Disclosure Information

Computed Tomography Imaging of the Coronary Arteries

Sixty-four-slice multidetector computed tomography: the future of ED cardiac care

Shih-Jen Chen, MD; Li-Tang Kuo, MD; Chao-Hung Wang, MD; Wen-Jin Cherng, MD; Ning-I Yang, MB, ChB; Chi-Wen Cheng, MD.

A new method for radiation dose reduction at cardiac CT with multi-phase data-averaging and non-rigid image registration: preliminary clinical trial

Journal of the American College of Cardiology Vol. 45, No. 11, by the American College of Cardiology Foundation ISSN /05/$30.

CT Imaging of Atherosclerotic Plaque. William Stanford MD Professor-Emeritus Radiology University of Iowa College of Medicine Iowa City, IA

Imaging congestive heart failure: role of coronary computed tomography angiography (CCTA)

Clinical Medicine Insights: Cardiology

The recent introduction of multirow detector computed

Radiation Dose Reduction and Coronary Assessability of Prospective Electrocardiogram-Gated Computed Tomography Coronary Angiography

Bypass Graft and Native Postanastomotic Coronary Artery Patency: Assessment With Computed Tomography

Diagnosis of coronary stenosis with CT angiography comparison of automated computer diagnosis with expert readings.

A Noninvasive Assessment of CAD

Image quality and, hence, the diagnostic value of cardiac. Imaging

Computer Aided Detection and Diagnosis: Cardiac Imaging Applications

Prognostic Value of Multidetector Coronary Computed Tomographic Angiography for Prediction of All-Cause Mortality

Cardiac Computed Tomography

Recent developments in cardiac CT

Interpreting CT Angiography: Three-Dimensional Reconstruction Techniques

Computed tomography in coronary imaging: current status

EXPERIMENTAL AND THERAPEUTIC MEDICINE 5: , 2013

QUANTITATIVE ASSESSMENT OF IMAGE QUALITY IN 64-SLICE-COMPUTED TOMOGRAPHY OF CORONARY ARTERIES IN SUBJECTS UNDERGOING SCREENING

b. To facilitate the management decision of a patient with an equivocal stress test.

Computer Assisted Coronary CT Angiography Analysis

A Pictorial Review of Coronary Artery Bypass Grafts at Multidetector Row CT*

Diagnostic Performance of MDCT for Detecting Aortic Valve Regurgitation

Εξελίξεις και νέες προοπτικές στην καρδιαγγειακή απεικόνιση CT. Σταμάτης Κυρζόπουλος Ωνάσειο Καρδιοχειρουργικό Κέντρο

Evidence for myocardial CT perfusion imaging in the diagnosis of hemodynamically significant coronary artery disease

General Cardiovascular Magnetic Resonance Imaging

, David Stultz, MD. Cardiac CT. David Stultz, MD Cardiology Fellow, PGY 6 March 28, 2006

Noninvasive Coronary Angiography Using Multislice Computed Tomography (MSCT) Jeffrey M. Schussler, MD, Paul A. Grayburn, MD

In Vivo 16-Slice, Multidetector-Row Computed Tomography for the Assessment of Experimental Atherosclerosis

Transcription:

Imaging Predictive Value of 16-Slice Multidetector Spiral Computed Tomography to Detect Significant Obstructive Coronary Artery Disease in Patients at High Risk for Coronary Artery Disease Patient- Versus Segment-Based Analysis Udo Hoffmann, MD; Fabian Moselewski, BS; Ricardo C. Cury, MD; Maros Ferencik, MD, PhD; Ik-kyung Jang, MD, PhD; Larry J. Diaz, MD; Suhny Abbara, MD; Thomas J. Brady, MD; Stephan Achenbach, MD Background In this study, we investigated the diagnostic value and limitations of multidetector computed tomography (MDCT) based noninvasive detection of significant obstructive coronary artery disease (CAD) in a consecutive high-risk patient population with inclusion of all coronary segments. Methods and Results In a prospective, blinded, standard cross-sectional technology assessment, a cohort of 33 consecutive patients with a positive stress test result underwent 16-slice MDCT and selective coronary angiography for the detection of significant obstructive CAD. We assessed the diagnostic accuracy of MDCT in a segment-based and a patient-based model and determined the impact of stenosis location and the presence of calcification on diagnostic accuracy in both models. Analysis of all 530 coronary segments demonstrated moderate sensitivity (63%) and excellent specificity (96%) with a moderate positive predictive value of 64% and an excellent negative predictive value (NPV) of 96% for the detection of significant coronary stenoses. Assessment restricted to either proximal coronary segments or segments with excellent image quality (83% of all segments) led to an increase in sensitivity (70% and 82%, respectively), and high specificities were maintained (94% and 93%, respectively). In a patient-based model, the NPV of MDCT for significant CAD was limited to 75%. Coronary calcification was the major cause of false-positive findings (94%). Conclusions For all coronary segments included, 16-slice MDCT has moderate diagnostic value for the detection of significant obstructive coronary artery stenosis in a population with a high prevalence of CAD. The moderate NPV of patient-based detection of CAD suggests a limited impact on clinical decision-making in high-risk populations. (Circulation. 2004;110:2638-2643.) Key Words: tomography atherosclerosis coronary disease Studies with electron beam computed tomography (EBCT) and early versions of multidetector computed tomography (MDCT) scanners equipped with 4 detectors and a temporal resolution of 250 to 330 ms demonstrated the ability of cardiac CT to detect significant coronary stenosis in selected patients with high image-quality data sets. However, the clinical applicability of these methods was limited because of the fact that roughly one third of all coronary artery segments could not be evaluated owing to stairstep and motion artifacts and the presence of calcification. When all coronary segments were included, diagnostic accuracy significantly decreased for both EBCT and MDCT (sensitivity, 68 4.3% and 63 2.9%, respectively; specificity, 68 0.2% and 71 0.2%, respectively). 1 The newest generation of MDCT scanners permits simultaneous acquisition of image data in 16 parallel cross sections with an in-plane resolution of 0.6 mm and a gantry rotation time of 420 ms that results in a temporal resolution of 210 ms. 2 Initial reports have suggested improved diagnostic accuracy for the detection of significant stenosis in assessable segments (92% sensitivity, 93% specificity) compared with selective x-ray coronary angiography. 3,4 Although the initial results are promising, a systematic and thorough analysis comparing a segment-based with a clinically more useful patient-based model, which includes all coronary artery segments as well as an assessment of technical limitations and the impact of image quality on diagnostic accuracy, has not been performed. Received February 23, 2004; de novo received April 16, 2004; revision received June 21, 2004; accepted June 22, 2004. From the Department of Radiology (U.H., F.M., R.C.C., M.F., S. Abbara, T.J.B., S. Achenbach) and the Division of Cardiology (F.M., I.-k.J., L.J.D., S. Achenbach), Massachusetts General Hospital, Boston, Mass, and the Department of Internal Medicine II (S. Achenbach), University of Erlangen, Erlangen, Germany. Correspondence to Udo Hoffmann, MD, Department of Radiology, Massachusetts General Hospital, 100 Charles River Plaza, Ste 400, Boston, MA 02114. E-mail uhoffman@partners.org 2004 American Heart Association, Inc. Circulation is available at http://www.circulationaha.org DOI: 10.1161/01.CIR.0000145614.07427.9F 2638

Hoffmann et al Coronary Artery Stenosis in CT 2639 The aim of this prospective, blinded, standard crosssectional technology assessment therefore was to test the ability of 16-slice MDCT to detect significant coronary artery stenoses based on the American Heart Association (AHA) classification of coronary artery segments. We evaluated the diagnostic accuracy on a per-segment and per-patient basis and determined the impact and underlying cause of misinterpretation. Methods Patients A cohort of 33 consecutive patients (27 male, 6 female; mean SD age, 57 9 years) scheduled for invasive coronary angiography on an inpatient basis because of suspected coronary artery disease (CAD; lead complaint of chest pain on the Canadian Cardiology Society scale of 1 to 3, with proven or suspected stress-induced myocardial ischemia) underwent cardiac MDCT within 1 day of coronary angiography. Patients in unstable clinical condition, without sinus rhythm, with impaired renal function, and possibly pregnant patients were excluded. All patients provided written, informed consent. The institutional review board of the Massachusetts General Hospital approved the study protocol. Study Design This study was designed as a prospective, blinded, standard crosssectional technology assessment between 16-slice MDCT and invasive selective coronary angiography ( gold standard ). Data Acquisition MDCT data were acquired with a Sensation 16 MDCT scanner (Siemens Medical Solutions). According to a previously published protocol, 3,5 images were acquired with 16 0.75-mm-slice collimation, a gantry rotation time of 420 ms, table feed of 2.8 to 3.8 mm per rotation, tube energy of 120 kv, and an effective tube current of 500 mas. Contrast agent (80 ml of Iodhexodol, 320 g/cm 3 ; Visipaque, Nycomed Amersham) was injected intravenously at a rate of 4 ml/s. Overlapping transaxial images were reconstructed with a mediumsharp convolution kernel (B35f) with an image matrix of 512 512 pixels, slice thickness of 1 mm, and an increment of 0.5 mm with an ECG-gated half-scan algorithm, with a resulting temporal resolution of 210 ms at the center of rotation. Image reconstruction was retrospectively gated to the ECG. The position of the reconstruction window within the cardiac cycle was individually optimized to minimize motion artifacts. On average, 4 data sets per patient were reconstructed. All 17 patients with a heart rate 65 bpm received 5 mg metoprolol intravenously before the MDCT scan. MDCT Data Analysis Two experienced observers, blinded to the patient s identity, clinical history, and results of selective coronary angiography, assessed the masked MDCT data sets. To assess internal validity, 50% of the MDCT data sets were read twice without the observer s knowledge. MDCT data were transferred to an offline image analysis workstation (Leonardo, Siemens Medical Solutions). Original axial images, thin-slice (5-mm) maximum-intensity projections (which display a stack of 5 consecutive original slices in 1 image), and multiplanar reformatted reconstructions rendered orthogonal and perpendicular to the vessel course of each respective segment were used for assessment. The MDCT data sets were evaluated for the presence of significant coronary artery stenosis within all 17 coronary segments (modified 16-segment model of the AHA, with segment 17 being the intermediate branch of the left coronary artery). The presence of stenosis was assessed by visual estimation. Any narrowing of the normal contrast-enhanced lumen to 50% that could be identified in at least 2 independent planes was defined as significant coronary artery stenosis. Image Quality Image quality was assessed for each coronary segment as excellent, limited, or not assessable. Reviewers defined the cause of impaired image quality as the presence of (1) calcified plaque, (2) motion artifacts (ill-defined vessel contours), (3) stairstep artifacts (misalignment of slices obtained from different heartbeats), or (4) image noise/suboptimal contrast enhancement. In addition, observers provided information on diagnostic certainty with regard to the absence or presence of significant CAD per patient (1 very uncertain, 2 uncertain, 3 unequivocal, 4 certain, 5 absolutely certain) and subsequent recommendations for patient management (coronary angiography indicated [yes/no]). Selective Coronary Angiography Selective coronary angiography (BICOR Coroskop Hi-P, Siemens Medical Systems) was performed with standard techniques through a transfemoral approach. Seven projections were obtained (left coronary artery, 4 views and right coronary artery, 3 views). However, owing to variability of the position of the heart, the angles of image acquisition were slightly different from patient to patient. The angiograms were quantitatively assessed with quantitative coronary angiography software (QCAPlus, Sanders Data Systems) by an independent and experienced interventional cardiologist unaware of the results of the CT examination. Significant coronary lesions were classified into significant stenosis 50% to 69% or 70% of luminal narrowing, thresholds that have been used in other MDCT studies. 6 8 Statistical Evaluation Measures of diagnostic accuracy of MDCT for the detection of significant coronary artery stenosis (sensitivity, specificity, positive predictive value, negative predictive value, and likelihood and diagnostic odds ratios with 95% confidence intervals) were calculated on a per-segment and per-patient basis. To determine the impact of image quality, analysis was carried out with and without the exclusion of segments with limited assessability as well as for proximal segments only. We also determined diagnostic accuracy for 2 routinely used positivity criteria for coronary artery stenosis ( 70% or 50% luminal narrowing), as determined by selective coronary angiography. Diagnostic certainty scores were compared with a paired 2-tailed t test. A probability value 0.05 was considered to indicate statistical significance. The intraobserver and interobserver variability for the detection of significant coronary artery stenosis was tested with a test. Results MDCT was performed without complications in all 33 patients. The mean heart rate at scan time was 60 7 bpm (range, 51 to 73 bpm). The mean scan duration was 20 3 seconds. In 24 patients, all 3 coronary arteries could be best visualized between 55% and 65% of the RR cycle. In 9 patients, the right coronary artery was best visualized at 35% of the RR cycle. Seventeen AHA coronary segments were analyzed in all patients, independent of image quality (n 530). Thirty-one segments could not be delineated on coronary angiography. Analysis was repeated with the exclusion of 92 segments (17%) with impaired image quality by MDCT (n 438). Among excluded segments, 46 were the left circumflex, 24 the left anterior descending, and 24 the right coronary artery, with segment 10 (n 6), segment 12 (n 10), and segment 16 (n 6) the most commonly affected.

2640 Circulation October 26, 2004 stenosis in 1 patient, mid-left circumflex and intermediate branch stenosis in another). In 3 patients (total of 5 vessels), MDCT detected CAD despite a normal coronary angiogram (2 proximal left circumflex, 1 proximal right coronary artery, 1 mid-right coronary artery, 1 mid-left anterior descending). Proximal Segments Fourteen patients had significant CAD in proximal coronary segments (1 2, 5 7, 11, 13; CAD prevalence, 42%). MDCT correctly detected significant CAD in 12 patients and correctly ruled out significant CAD in 17 patients. In 2 patients, MDCT failed to detect significant CAD, and in 2 patients, MDCT detected CAD despite the absence of significant epicardial coronary stenosis (stenosis 50% diameter reduction) on the coronary angiogram. Overall, MDCT was more sensitive than specific for the detection of significant CAD in this high-risk patient population. Sensitivity and specificity were insensitive to the positivity criteria as defined by coronary angiography ( 50% versus 70% stenosis). MDCT test characteristics are summarized in Table 1. Figure 1. A D, Patient with 94% stenosis of proximal left anterior descending coronary artery (LAD) detected both on MDCT and selective coronary angiography. A, Axial thin-slice maximum-intensity projection (5-mm) MDCT image showing significant narrowing of vessel lumen, with residual contrast filling in presence of eccentric, noncalcified plaque (arrow). B, Curved multiplanar reconstruction along centerline of LAD, demonstrating contrast enhancement of mid and distal LAD segments. C, Volume-rendered 3D image (surface shadowing display) of heart, demonstrating tomographic view of lesion (arrow). D, Invasive selective coronary angiography demonstrates eccentric stenosis of proximal LAD with residual filiform lumen (arrow). Quantitative coronary angiography determined 94% luminal obstruction. All other abbreviations are as defined in text. Patient-Based Analysis The prevalence of significant CAD (at least 1 stenosis 50% diameter reduction) among 33 patients was 67%. On the basis of invasive coronary angiography, 22 patients had significant coronary artery disease (1-vessel disease in 8 patients, 2-vessel disease in 7, and 3-vessel disease in 7). All Segments MDCT correctly identified significant CAD (presence of at least 1 stenosis 50% diameter reduction) in 19 patients and correctly ruled out CAD in 9 patients. In 2 patients, MDCT failed to detect significant CAD (mid-right coronary artery Segment-Based Analysis Coronary angiography by quantitative methods identified 54 significant lesions ( 50%) in 530 segments (prevalence, 9%) (Figure 1). Proximal lesions (n 33 in segments 1 2 [n 14], 5 7 [n 13], 11 [n 4], and 13 [n 2]) were more frequent than distal lesions (n 19). Forty-six lesions (28 in proximal segments, 18 in distal segments) had 70% luminal obstruction. Table 1 provides detailed data on false- and truepositive/negative findings of MDCT for the detection of significant obstructive CAD in all segments, proximal segments, and evaluable segments compared with selective invasive coronary angiography. MDCT test characteristics are summarized in Table 2. All Segments MDCT correctly detected 34 lesions and failed to detect stenoses in 20 segments with 50% stenosis (sensitivity, 63%). The sensitivity increased slightly to 67% for lesions of 70% stenosis. Specificity was not different for the detection of stenosis 50% and 70% luminal narrowing (95% and 96%, respectively). The sensitivity of MDCT did improve by 19% and 22% (for 50% and 70% stenosis, respectively) when only proximal segments were evaluated, primarily because most lesions that were not detected by MDCT occurred in distal segments (n 13 and n 12 for 50% and Figure 2. A C, Patient without stenosis of the proximal right coronary artery (RCA) as determined by selective coronary angiography. A, Axial thin-slice maximumintensity projection (5-mm) MDCT image demonstrates significant calcified plaque in the proximal RCA (arrow). B, Crosssectional reconstruction perpendicular to centerline of RCA demonstrates massive calcification, apparently without residual contrast-filled coronary lumen. C, Invasive selective coronary angiography demonstrates normal angiogram without luminal obstruction of the proximal RCA. All other abbreviations are as defined in text.

Hoffmann et al Coronary Artery Stenosis in CT 2641 Figure 3. A C, Patient with 72% stenosis of mid left circumflex coronary artery (LCX) detected by selective coronary angiography and missed by MDCT. A, Axial thin-slice maximum-intensity projection (5-mm) MDCT image demonstrates significant calcified and noncalcified plaque in the mid-lcx with apparently preserved contrast-filled coronary lumen (arrow). B, Curved multiplanar reconstruction along centerline of LCX seems to confirm this finding. C, Invasive selective coronary angiography demonstrates diffuse, significant narrowing of proximal LCX (arrow). Quantitative coronary angiography determined 72% luminal obstruction. All other abbreviations are as defined in text. 70% stenosis, respectively). The mean diameter reduction of stenoses ( 50%) that were missed by MDCT (76 14%) was not significantly different from the stenoses that were detected (78 17%, P 0.56). Evaluable Segments After exclusion of 92 segments classified as unevaluable by MDCT, coronary angiography identified 43 significant lesions ( 50%) in 438 segments (prevalence, 10%). There were 7 obstructive coronary lesions noted in segments that could not be evaluated by MDCT. MDCT correctly detected 30 lesions and failed to detect stenosis in 13 segments (sensitivity, 70%). In 371 segments, stenosis was ruled out correctly by MDCT, and in 22 segments, the degree of narrowing was overestimated (specificity, 94%). The sensitivity of MDCT for the detection of significant luminal narrowing did slightly increase after exclusion of segments with limited assessability, whereas specificity was not affected. Overall, MDCT was more specific than sensitive for the detection of coronary lesions on a segmental basis. For evaluable segments, sensitivity (70% versus 71%) and specificity (94% versus 94%) were insensitive to positivity threshold ( 50% versus 70% stenosis as detected by coronary angiography, respectively). Diagnostic Certainty Both observers were confident in their final diagnosis with regard to the presence or absence of significant CAD per TABLE 1. TP, FN, TN, and FP Findings of MDCT for Detection of Significant Obstructive CAD in All Segments, Proximal Segments, and Evaluable Segments Compared With Selective Invasive Coronary Angiography TP FN TN FP All segments Lesions 50% diameter reduction 34 20 457 19 Lesions 70% diameter reduction 31 15 462 22 Proximal segments Lesions 50% diameter reduction 27 6 185 13 Lesions 70% diameter reduction 25 3 188 15 Evaluable segments Lesions 50% diameter reduction 30 13 371 22 Lesions 70% diameter reduction 30 12 372 22 TP indicates true-positive; FN, false-negative; TN: true-negative; and FP, false-positive. All other abbreviations are as defined in text. patient (mean value for observer 1, 4.02 1.09; for observer 2, 4.09 0.87; P 0.66). In patients in whom CAD was either missed or overestimated, diagnostic certainty was lower than in patients diagnosed correctly (3.71 1.16, P 0.2). Underlying Cause of False-Negative and False-Positive Findings We determined the underlying cause with regard to the presence of calcification, image noise/motion, and location in the 20 segments with false-negative and the 19 segments with false-positive MDCT results. Calcification was identified as the underlying reason for overestimation of coronary lumen obstruction in the overwhelming majority of false-positive findings (94%) (Figure 2). On the contrary, calcification was much less of a factor in false-negative findings (14%). Instead, image noise and suboptimal contrast enhancement in small vessels ( 1.5-mm diameter) was the predominant cause of underestimation (66%) (Figure 3), eg, left circumflex with right dominant vessel supply. In some cases (20%), the great cardiac vein overlapped the left circumflex (segment 13) or the intermediate branch (segment 17) and caused false-negative results. Overall, pitfalls occurred independent of vessel type (right coronary artery, n 14; left anterior descending and intermediate branch, n 12; and left circumflex, n 13). However, the first diagonal branch, the proximal left circumflex segment, and the intermediate branch were the most frequent locations for false-positive findings, whereas the mid-right coronary artery, the mid-left anterior descending, and the first obtuse marginal branch were the most frequent locations for false-negative findings. Intraobserver and Interobserver Agreement Intraobserver agreement was excellent ( 0.81), whereas interobserver agreement was good ( 0.68), based on the comparison of all coronary segments. Discussion In our analysis of 33 patients with a high prevalence of CAD (67%), we found a moderate positive predictive value (64%) and sensitivity (63%) and a high negative predictive value (96%) and specificity (96%) for 16-slice MDCT in the detection of significant coronary stenosis in an evaluation of all 17 segments of the coronary artery tree. Increased temporal and spatial resolution led to a decrease in the number of segments with impaired image quality (17%) compared with

2642 Circulation October 26, 2004 TABLE 2. Diagnostic Accuracy and Predictive Value of MDCT for Detection of Significant Stenosis (>50% Luminal Narrowing) on Selective Angiography Sensitivity Specificity PPV NPV LR LR DOR Segment-based analysis All segments 0.63 (0.50 0.76) 0.96 (0.94 0.98) 0.64 0.96 15.77 0.39 40.89 Evaluable only 0.70 (0.57 0.82) 0.94 (0.92 0.97) 0.58 0.97 12.46 0.32 38.92 Proximal segments 0.82 (0.70 0.94) 0.93 (0.90 0.97) 0.68 0.97 12.46 0.19 64.04 Patient-based analysis All segments 0.86 (0.72 1.01) 0.82 (0.60 1.04) 0.90 0.75 4.75 0.17 28.5 Proximal segments 0.86 (0.67 1.04) 0.89 (0.76 1.03) 0.86 0.89 8.14 0.16 51.00 For segment-based analysis for all segments, analysis of 530 segments according to modified AHA classification of coronary segments; evaluable only, 438 segments (92 segments were excluded because of impaired image quality); proximal segments, 1, 2, 5, 6, 7, 11, 13. For patient-based analysis, there were 33 consecutive patients. PPV indicates positive predictive value; NPV, negative predictive value; LR, positive likelihood ratio; LR, negative likelihood ratio; and DOR, diagnostic odds ratio. All other abbreviations are as defined in text. Values in parenthesis represent upper and lower bound for 95% confidence interval. previous scanner generations ( 33%). 6 12 A patient-based analysis of the absence/presence of significant CAD demonstrated good diagnostic accuracy; however, the negative predictive value was only moderate (75%). Given the high pretest probability of disease in our population, the test appears to be of limited diagnostic value in patients at high risk for significant CAD. Confidence of the observers with regard to the final diagnosis for the presence or absence of significant CAD per patient was similar between correct and incorrect assessments. We identified calcification as the major underlying cause for overestimation of luminal narrowing and motion/noise and contrast-related image deterioration as the major reason for false-negative MDCT findings. We also demonstrated that current CT technology is insensitive to the degree of significant narrowing (50% versus 70% in selective angiography). Most previous studies were limited to the evaluation of high image quality data sets in selected patients, 6,10 15 and analysis was performed on a per-vessel basis in evaluable proximal segments. Our analysis systematically lays out the differences between a segment-based and a patient-based approach based on all 17 coronary segments, as well as the impact of coronary calcification and poor image quality on diagnostic accuracy in a consecutive patient cohort. Our results demonstrate that negative and positive predictive values of MDCT for the detection of significant CAD are different from previously established segment-based analyses and a patient-based analysis. Segment-based analysis demonstrated a low positive but a high negative predictive value. In contrast, detection or exclusion of significant CAD per patient demonstrated a moderate negative predictive value (75%) and a high positive predictive value. Per-patient analysis had better sensitivity than per-segment analysis. It should be noted that an increase in sensitivity is merely dependent on the prevalence of 1-, 2-, or 3-vessel disease, with maximal differences in 3-vessel disease. Most studies so far have been conducted in patients referred for invasive coronary angiography, a population at high risk for significant CAD. Subsequently, the prevalence of CAD in most studies was even higher than in this study 6,8,11,13,14 (mean prevalence, 72% versus 67%). Given the high pretest probability of CAD, reliable exclusion of significant CAD (high negative predictive value) per patient would represent the most valuable diagnostic information in this patient cohort. Obviously, this question cannot be addressed by a segment-based analysis. Because of a moderate negative predictive value (75%), coronary CT angiography may be of limited diagnostic value in patients at high risk for significant CAD. Instead, CT-based coronary angiography may be more useful in the diagnostic workup of patients at intermediate risk for CAD (eg, younger symptomatic subjects with multiple risk factors). In those patients, not only is the prevalence of coronary calcification, a major contributor to false-positive findings, lower but also a high positive rather than a high negative predictive value of MDCT would result in significant changes in patient management, ie, referral for coronary angiography. Although it might be difficult to perform large-scale prospective trials in view of the dynamic technical development of CT technology, such trials are necessary to establish cardiac MDCT as a clinical application and more important, to identify the group of patients in whom cardiac CT has the most diagnostic value. In addition, it is likely that 16-slice scanners will continue to be used by many institutions for cardiac imaging. We confirm the findings of initial reports on 16-slice MDCT by demonstrating that improved image quality achieved by better spatial and temporal resolution led to a significant decrease in the number of segments that could not be evaluated compared with 4-slice MDCT or EBCT. Our finding of 17% is slightly higher than previously reported (7% to 12%) 3,13 but can also be attributed to the fact that previous studies were restricted to coronary vessels 1.5 mm in diameter. Similar to previous reports, we have demonstrated that 16-slice MDCT permits the detection of significant CAD in proximal segments with higher sensitivity (82%) and specificity (93%) 3,13 compared with studies with 4-slice MDCT technology. However, despite the relatively low number of unevaluable segments, the sensitivity for segment-based detection of significant CAD including all 17 coronary segments remains limited (63%). Whereas previous studies simply mentioned calcification and motion artifacts as major confounders of image quality,

Hoffmann et al Coronary Artery Stenosis in CT 2643 we thoroughly analyzed sources of misinterpretation and could demonstrate that coronary calcification is the major reason for overestimation of luminal narrowing but that it has relatively little impact on the failure to detect coronary stenosis. Although it was beyond the goal of this study, evaluation of different display settings may play a key role in potentially overcoming this limitation. On the contrary, reduced image quality due to noise, coronary motion, and suboptimal contrast enhancement can lead to failure to detect significant stenosis. Our data demonstrate that qualitative assessment of the presence of significant stenosis may be insensitive to the severity of luminal obstruction, ie, between 50% and 70% of luminal narrowing with current CT technology. In fact, even in a proximal coronary vessel with a 3- to 4-mm lumen diameter, the difference between a 50% and a 70% stenosis is very small in terms of diameter (0.6 mm and 0.8 mm, respectively). However, whether spatial resolution of current 16-slice MDCT technology is sufficient for quantitative evaluation of the degree of stenosis was not explored in this study. Limitations The number of patients and thus, the number of analyzed coronary segments was relatively small. Because of the lack of standardized evaluation algorithms, MDCT analysis was based on visual assessment of individual image display settings. The accuracy for calcium detection may have been artificially low, because no unenhanced scan was performed: smaller calcified plaques with a density equal to the contrastenhanced lumen may thus have been missed by MDCT. However, small calcifications may not result in overestimation of the degree of stenosis. In addition, the frequent use of -blockers to lower heart rate is a limitation of the technique. Conclusions In conclusion, 16-slice MDCT has moderate diagnostic value for the detection of coronary stenoses when all coronary segments are included in the analysis. In a patient population with a high prevalence of hemodynamically significant CAD, the moderate negative predictive value for patient-based detection of CAD suggests a limited impact on clinical decision-making in high-risk populations. Acknowledgments This study was supported in part by the New York Cardiac Center, New York, NY. F. Moselewski was supported by the Daniela and Juergen Westphal-Stiftung, Flensburg, Germany. S. Achenbach was supported by Deutsche Forschungsgemeinschaft, Bonn, Germany. References 1. Hoffmann U, Hadvar J, Dunn E, et al. Is CT angiography ready for prime time? a meta-analysis. J Am Coll Cardiol. 2004;43(suppl A):312A. Abstract. 2. Flohr T, Bruder H, Stierstorfer K, et al. New technical developments in multislice CT, part 2: sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac imaging. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr. 2002;174:1022 1027. 3. Ropers D, Baum U, Pohle K, et al. Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation. 2003;107:664 666. 4. Nieman K, Cademartiri F, Lemos PA, et al. Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation. 2002;106:2051 2054. 5. Ohnesorge B, Flohr T, Becker C, et al. Cardiac imaging by means of electrocardiographically gated multisection spiral CT: initial experience. Radiology. 2000;217:564 571. 6. Becker CR, Knez A, Leber A, et al. Detection of coronary artery stenoses with multislice helical CT angiography. J Comput Assist Tomogr. 2002; 26:750 755. 7. Achenbach S, Giesler T, Ropers D, et al. Detection of coronary artery stenoses by contrast-enhanced, retrospectively electrocardiographicallygated, multislice spiral computed tomography. Circulation. 2001;103: 2535 2538. 8. Leber AW, Knez A, Becker C, et al. Non-invasive intravenous coronary angiography using electron beam tomography and multislice computed tomography. Heart. 2003;89:633 639. 9. Achenbach S, Ulzheimer S, Baum U, et al. Noninvasive coronary angiography by retrospectively ECG-gated multislice spiral CT. Circulation. 2000;102:2823 2828. 10. Kopp AF, Schroeder S, Kuettner A, et al. Non-invasive coronary angiography with high resolution multidetector- row computed tomography: results in 102 patients. Eur Heart J. 2002;23:1714 1725. 11. Nieman K, Rensing BJ, van Geuns RJ, et al. Usefulness of multislice computed tomography for detecting obstructive coronary artery disease. Am J Cardiol. 2002;89:913 918. 12. Nieman K, Oudkerk M, Rensing BJ, et al. Coronary angiography with multi-slice computed tomography. Lancet. 2001;357:599 603. 13. Nieman K, Cademartiri F, Lemos PA, et al. Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation. 2002;106:2051 2054. 14. Knez A, Becker CR, Leber A, et al. Usefulness of multislice spiral computed tomography angiography for determination of coronary artery stenoses. Am J Cardiol. 2001;88:1191-119-4. 15. Kopp AF, Schroeder S, Kuettner A, et al. Coronary arteries: retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window. Radiology. 2001;221: 683 688.