Linear Occlusion. By Dr. John P. Frush

Similar documents
Concepts of occlusion Balanced occlusion. Monoplane occlusion. Lingualized occlusion. Figure (10-1)

Horizontal jaw relations: The relationship of mandible to maxilla in a

529-A Treatment and Management of the Edentulous Patient. Upon completion of this course the student should be able to:

Horizontal Jaw Relation

Prosthodontics. Dental articulator. 1-Allow most of the prosthetic work to be done in the absence of the patient.

Arrangement of the artificial teeth:

AD2 MEASURES CONDYLE DISPLACEMENT (MCD) MANUAL

Dr Mohammed Alfarsi Page 1 9 December Principles of Occlusion

ALTERNATE OCCLUSAL SCHEMES

Lab Procedure Prior to Try-in

The Hanau Modular Articulator System 194 Fixed 11 cm width, adjustable Radial-Shift Guidances. Illustrated Instruction Manual

Articulators. 5- Wax up and refining the occlusion for dental restorations.

Occlusion in complete denture

Arrangement of posterior artificial teeth Standardized parameters Curve of Wilson Curve of Spee

Complete Denture Clinic Complete Removable Dental Prosthesis Procedures

This article discusses the highlights of making personalized

Occlusion and removable prosthodontics

Bone Reduction Surgical Guide for the Novum Implant Procedure: Technical Note

Splint Appliance. Selection Guide. Great Lakes. See inside...

Removable Prosthodontics. Complete Denture Procedures for a Team Approach

Kois Dento-Facial Analyzer System Instructions

by VIKTOR FÜRGUT Profile Compass Measuring Compass Occlusal Plane Indicator chrome-plated Modeling Instrument

Denture Troubleshooting Guide

Restoring Severe Anterior Wear Cases; A Step by step Process

PREDICTABILITY IN COMPREHENSIVE RECONSTRUCTION Bite registration and recovery process for comprehensive reconstructive cases.

The Effect of the Central Bearing Plate Form on the Fischer Angle

3000 Series Articulator System

Surveying. 3rd year / College of Dentistry/University of Baghdad ( ) Page 1

Vertical relation: It is the amount of separation between the maxilla and

Removable Prosthodontics. Complete Denture Procedures for a Team Approach in the Home

Jaw relations and jaw relation records

Jaw relation registration in RPD

See the end from the beginning

DENT Advanced Topics in Removable Prosthodontics, Winter 2008

Occlusion & Prosthodontics

Selection and arrangement of teeth in rpd

INSIGHT & INNOVATION. Envelope of Parafunction: 7 Steps of Treatment Planning Many methods and theories have been

Interim Denture Interim Complete Dental Prosthesis Clinical Steps

KaVo PROTAR evo. Exciting design and function.

Try-in of the Trial Denture by Dr. Mahmoud Ramadan

OBTAINING CONSISTENT mandibular

The De Vreugd Occlusal Compass

The Gerber Articulator and System of Full Denture Construction

UDELL DENTAL LABORATORY Instructions for Use

Exciting design and function.

Annals and Essences of Dentistry

Implant and Tooth Supported Full-Mouth Rehabilitation with Hobo Twin-Stage Technique

CLEAR, THIN, & STRONG

The Hanau Modular Articulator System 190 Fixed 11 cm width, adjustable Bennett Angle and/or Adjustable Protrusion. Illustrated Instruction Manual

How to provide intraoral scans to SomnoMed for the production of SomnoDent device.

Full mouth occlusal rehabilitation; by Pankey Mann Schuyler philosophy

MemRx Orthodontic Appliances

Face-Bow Instructions

Case report: Lingualized occlusion -A better way for enhancing function & esthetic

(12) Patent Application Publication (10) Pub. No.: US 2005/ A1

Muscles of mastication [part 1]

Archived SECTION 14 - SPECIAL DOCUMENTATION REQUIREMENTS

AN EVALUATION OF MANDIBULAR BORDER MOVEMENTS THEIR CHARACTER AND SIGNIFICANCE

The M Ruler (Figure 6) Figure 6 M Ruler (Figure 7)

Symposium on Occlusal Articulation. Mandibular Movement Recordings and Articulator Adjustments Simplified. Harry C. Lundeen, D.D.S.

Balancing Ramp: An Excellent way to enhanced the Retention, Stability and Function of Denture.

TURN CLASS II INTO SIMPLE CLASS I PATIENTS.

Construction of Removable Partial Denture

Tooth preparation for posterior fi xed partial denture (FPD) Tooth preparation for anterior fi xed partial denture (FPD)

Methods of determining vertical dimension of occlusion

Occlusal rehabilitation of posterior fixed prostheses: A clinical report

Combi ArtiCulAtor SyStem instruction manual

B U J O D. Review Article. Occlusal Schemes for Complete Dentures - A Review Article. Savitha et al. Authors: Savitha K. C.*, Srinivas L.

Connect your Scanner to SomnoMed Canada. SOMGauge Protrusive Bite Recording - Manual. Scanning Impressions - Lower and Upper

We have simplified the. for you! Just a few steps to the articulator system of your choice! choose the perfect articulator for you!

Principle of Occlusion

MEDICAL ASSISTANCE BULLETIN COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF PUBLIC WELFARE

Removable partial dentures

Removable Prosthodontics. Summative Evaluations

Fixed Twin Blocks. Guidelines for case selection are similar to those for removable Twin Block appliances.

SURVEYING OF REMOVABLE PARITAL DENTURES FEB, 11, 2015

Nagri D et al. Linear occlusion and Neutral Zone recording for severely resorbed ridges

Dr.Mikulás Krisztina. Fabrication of the trial denture, and the try in procedure

Unique Dental Supply. Catalog We Bring World Quality Products to Enhance your Business QUALITY PRODUCTS SINCE 1974

ident CT Guide Protocol

Prosthetic Options in Implant Dentistry. Hakimeh Siadat, DDS, MSc Associate Professor

MM01-Facebow And Bite Registration Procedure Checklist

Occlusal Splint Fabrication Technique

8500 Series Articulator and QuickMount Face-Bow Instruction Manual

ARAB AMERICAN UNIVERSITY. Lab. Manual. Prosthetic Dentistry1; Removable Prosthodontics. 3 rd year

Table of Contents. Flexi-Overdenture Characteristics

Indirect retainers. 1 i

Attachment G. Orthodontic Criteria Index Form Comprehensive D8080. ABBREVIATIONS CRITERIA for Permanent Dentition YES NO

Jaw relation (Maxillomandibular relationship): any one of the infinite

Deep and cross bite (class II and class III) Special Edition

JANUARY 2017 REVOLUTIONIZING. the Complete Denture Process

Application of ARCUS digma I, II systems for full mouth reconstruction: a case report

UNDERSTANDING DIGITAL DENTISTRY: CBCT AND INTRA-ORAL 30 SCANNING

Full-mouth rehabilitation of a patient with severe attrition using the Hobo twin-stage procedure

PATIENT INSTRUCTIONS FOR BRACE REMOVAL

Factors of Mandibular Movements related to occlusal Morphology

Mandibular ridge changes after adaptation. An issue of shortened dental arch to be considered from changes of soft tissues after unattended tooth loss

Shadeguides Finding the Centric Relation The Kois Deprogrammer

Chapter 12. Prosthodontics

Using the Lucia Jig to take an accurate & reliable centric relation bite registration

Transcription:

Linear Occlusion By Dr. John P. Frush Doctor Frush graduated from the University of Southern California in 1935 and has a private practice in San Marino, California. He is a member of the American Prosthodontic Society and a member of the Postgraduate Staff of the University of Southern California. This paper was presented by Dr. Frush at the 102 nd Annual Session of the Illinois State Dental Society in Springield. Linear occlusion is an entirely new occlusal design. It is intriguing because of its simplicity and its remarkable success in practical usage. By incorporating an extremely effective chewing mechanism with linear stability in the occlusion, an entirely new combination of prosthetic advantages is achieved. Linear occlusion definitely provides a stabilizing effect on the denture bases during function. Heretofore, occlusion for full dentures has been limited to three-dimensional (cusp) occlusion and two-dimensional (flat plane) occlusion. When the combined points of contact on the occluding surface form a flat plane, the tooth is two-dimensional. When any portion of the occluding surface is above another portion of the occluding surface, the tooth is three-dimensional All of the posterior tooth designs which have been available fall into either one of these categories. Two-Dimensional: Fench, Halls inverted Cusp, Myerson & Sears, Tru-Byte Rational, Univac Bio-Mechanical. Three-Dimensional: Criterion, Myerson s Synchronized, Pilkington- Turner. Tru-Byte Dentron, Tru-Byte Fournet, Tru-Byte Functional, Tru-Byte New Hue Diatoric, Tru-Byte 20 Degree, Tru-Byte 30 Degree, Tru-Byte 33 Degree. Univac Nuform, Univac NIC, Verident NIC. Linear occlusion allows us to complete the geometric classification of occlusion by providing a one-dimensional occlusal design. As such, it provides the practitioner with a valuable new tool to cope with prosthetic problems.

Geometric classification of occlusion is not a pure geometric interpretation of the entire bilateral occluding surfaces of posterior teeth. A geometric classification of occlusion describes the dimensional contact (one, two or three dimensional) between the occluding surfaces of any two opposing teeth. 1) Cusp Occlusion In cusp occlusion the contact between the opposing surfaces of any two teeth occurs in three dimensions. These dimensions are the width of the occluding surface, the length of the occluding surface, and the depth of the occluding surface. THREE DIMENSIONAL (CUSP) Length Width Height These dimensions are the width of the occluding surface and the length of the occluding surface. 3) Linear occlusion Linear occlusion is a onedimensional contact between two opposing posterior teeth. The contact occurs only in one dimension which is the length of the contacting blade (not surface). This blade, being always in the form of a straight line, geometrically constitutes length in occlusal contact without either width or depth of occusal contacts. ONE DIMENSIONAL (LINEAR) Length 2) Flat Plane Occlusion In flat plane occlusion the contact between two opposing posterior teeth occurs in two dimensions. TWO DIMENSIONAL (FLAT PLANE) Length Width There is ample clinical evidence that one-dimensional occlusion has certain advantages over either two or three-dimensional occlusion because of the geometric simplicity of the occlusal contact. The reduction in the amount of occluding surface accomplished by one-dimensional occlusion likewise reduces the potential occlusal deflections which may occur with broader contacting surfaces. Directions of Force Directions of force developed in any kind of surface contact between opposing posterior teeth (two or

three-dimensional occlusion) necessarily change with any alteration in the relationship of these opposing occlusal surfaces, such as with lateral excursion of the mandible. Directions of force in three-dimensional occlusion can be determined by observing the slopes of the contacting inclined surfaces in Diagram A. However, if the relationship of there contacting surfaces suddenly changes, through lateral excursion of the mandible, the directions of force also change, as in Diagram B. directions of force are vertical to the flat surface opposing the blade, as in Diagram A. Any change in the position of the linear contact against the upper surface, as in a lateral excursion of the mandible, would not appreciably change the direction of force, which still remains essentially vertical Diagram B. In the opposite excursion of the mandible, the blade still contacts a flat surface and the direction of force remains essentially vertical, Diagram C. Likewise, in two-dimensional occlusion, the directions of force can be determined by observing the angle of the surface contact. Of course, in two-dimensional occlusion the surface contact is presumably occurring at a flat or level angle, Diagram A. However, the slightest change in relationship of these opposing surfaces, such as a lateral excursion of the mandible, produces a bilateral imbalance with an attendent tipping of the denture base in relationship to its original position on the tissue, Diagram B. Whereas, in linear occlusion the To a patient, chewing efficiency is apparently first related to the ease with which he can penetrate and cut the bolus of food. Next, chewing efficiency to a patient is related to the comminution of the bolus of food. Next, chewing efficiency to a patient is related to the comminution of the bolus after it is penetrated and cut. Many methods of introducing easier penetrating and cutting power to the occlusion have been attempted in the form of cutter bars which occur in various shapes. If one studies the various types of cutter bars it becomes apparent that the simplicity of a straight line (one-dimensionsal) occlusal contact is not maintained. Therefore, it is doubted that the

efficiency of a simple blade contact in the occlusion has been properly documented. One of the prerogatives every dentist has is to make his own comparision and personally document the practical difference between linear occlusion, whichever he has been using. The best way to do this is on an existing set of dentures which are at the present time less than satisfactory. The attached procedure should be followed. The one-dimensional; occlusion at present in use (about 20,000 cases) includes a crushing surface lingual to the linear contact as shown in the diagram below: gypsum is crushed by stainless steel balls, the size of the particles is determined by adjusting the proximity of the stainless steel balls. It is interesting to note that in the finest of particles the balls never quite touch. If one studies the diagram below, it becomes apparent that the space between the crushing surfaces varies greatly from the extreme lingual (L) to the blade contact (B). Apparently, from clinical experience, the separation of the crushing surfaces at L should be no more than a millimeter (.040 ). This crushing surface, in order to maintain true linear contact between the occluding surfaces, never touches. Carbon paper will determine this when the dentures are seated at the delivery appointment. However, it can be seen that the person who sets up the teeth and finishes the dentures has control over the distance between the crushing surfaces lingual to the blade. As in a ball mill, or any crushing mechanism, the proximity of the crushing surfaces determines the fineness of the separated particles. For instance, in the ball mill where Clinical evidence points to improvement in comfort, stability and chewing as a result of onedimensional occlusion. This seems sufficient to indicate an advantage over two-dimensional and threedimensional occlusion. A very important aspect of this innovation is that it seems to provide the following: 1) Reduction of needless problems due to complexities of occlusal contacts and resultant deflections. 2) Simplification of prosthodontic procedure. 3) Reduced post-insertion adjustments with an attendent

time-saving factor in both laboratory and operatory. 4) A general increase in chewing efficiency, comfort and stability of full dentures. Denture Techniques Whatever denture techniques or procedures being use can be continued. For instance, impressions and relationships, the mounting and re-mounting of the dentures, etc, can be done according to present practice. When the dentures are constructed with flat plane or cusp teeth, any kind of articulator can be used. However, with linear occlusion there is a definite requirement. Any articulator with an incisal guide pin, a flat incisal guide plate, and an adjustable condyle inclination can be used. The Hanau articulator is ideal for this, the exception being the extremely old Hanau with the cup type of incisal guidance. Centrimatic articulators are recommended because they already have a fixed 12 degree condylar inclination and a flat incisal guide plate. Laboratory Procedures When one-dimensional occlusion is used: 1) The lower anterior teeth may be set with as much horizontal overlap as necessary, but the vertical overlap should be zero. This is a requirement of linear occlusion. To have any interference in right or left lateral or protrusive (cusp rise) defeats the bilateral line contact necessary between the upper and lower dentures at all times. Protrusive balance is desirable. 2) All the lower teeth will be set on a flat occlusal plane. The anterior level of the occlusal plane will be the lower anterior teeth, and the posterior level of the occlusal plane will be approximately at the top of the retromolar pads. 3) Technicians should set the lower posteriors with the buccal surfaces nearly straight up and down. This will bring the linguals of the first and second molars almost as high as the buccal blade on these teeth. The linguals of the bicuspids will not be as high because of the basic design. The bicuspidswere designed to cut more than to crush; therefore, it is not expected that the occlusal surface lingual to the blade on these teeth will be used as much for crushing as will the first and second molars. 4) The upper posteriors are set with the occlusal surfaces level and with the central fossa of the upper teeth against the blade of the lower posterior teeth. If the linguals of the lower molars and of the upper molars touch when the upper posteriors are set, it is okay. Note: The separation between the linguals of the upper and lower posterior teeth is eventually achieved at the expense of the lower posteriors. After the teeth are completely waxed, the occlusal surface lingual the blade of the lower

posteriors is ground for proper clearance. 5) Following are the salient features of a one-dimensional occlusion in the set-up: 1. All the lower teeth on a flat occlusal plane; this plane extending from the lower anteriors towards the top of the retromolar pads. 2. The combined buccal blades of the lower posterior teeth should form a perfect straight blade. This blade should be perfectly straight to support one-dimensional contact against the opposing occlusion. 3. The crushing table lingual to the buccal blade on the lowers should be adjusted to create an inter-occlusal crushing space of approximately one millimeter. 4. Zero vertical overlap between the anterior teeth. It should be noted here that any interference in a protrusive movement requires a change in vertical to avoid this interference. A forced change in vertical dimension in this instance produces the same kind of a deflection of the denture base on the mucosa as would a cusp rise in lateral excursion of the mandible. 6) Cusp rise is removed from the upper occlusion before the dentures are delivered to the patient. This is why a flat incisal guide plate must be used on the articulator. It is best to accomplish this after the dentures are deflasked and remounted on the articulator. If the laboratory (or the dentist) does not usually re-mount the dentures before delivering them to the dentist, the cusp rise would be removed in the wax-up. The laboratory procedure for removing cusp rise on the articulator is as follows: 1. Set the incisal guidance at zero degrees and the condylar inclination at 12 degrees. (The Centrimatic articulator automatically has these features;) 2. Adjust the upper occlusion until the pin touches in centric. 3. Remove any contact marks which appear on the crushing table of the lower posteriors. Never grind the lower blade itself. 4. Run the articulator through right and left lateral. Balance is automatically achieved by grinding away the interferences, revealed by the carbon paper on the upper teeth, which lift the pin off the incisal guidance plate. These must be removed to eliminate cusp rise. 5. Continue to relieve the upper occlusion through right and left lateral until the pin maintains contact with the incisal guide plate through all excursions. This automatically balances the occlusion! 6. If necessary, remove any interferences in protrusive by grinding the lower anteriors.

When switching from flat plane or cusp occlusion to linear occlusion, the set-up is the same as for a set-up of linear occlusion on new dentures. Note: If the anterior teeth are locked or touch in centric after the dentures are mounted on the articulator, the technician should arbitrarily open the articulator to relieve this anterior interference. This arbitrary opening is possible only with linear occlusion. It should not be done with either cusp or flat plane teeth because neither of these can accommodate the slight change in centric occlusion which is affected by such a procedure. Use the following technique for switching posteriors: 1) Carefully position the occlusion of the dentures into centric contact. Do not use a wax or plaster relationship for this purpose. Sticky was the teeth together preparatory for mounting. 2) Mount the dentures with the occlusal plane sloping up and back. If it is customary to use a face bow for mounting dentures, this is even better. 3) Set the teeth and cure. Either cold cure or heat cure is satisfactory. In the event cold cure is used, the articulator should be opened slightly to accommodate for the shrinkage which always occurs. General Considerations The author of this memorandum on technique has personally taught more than 500 dental technicians the use of one-dimensional occlusion in dentures. The greatest obstruction to learning the proper application of one-dimensional occlusion by the technician is habit. The habits developed in full denture work by a good technician over a period of years are necessarily associated with either flat plane teeth or cusp teeth. With these two types of occlusion, there has been little need for precision placement of the individual teeth. For instance, the technician learns to set teeth very rapidly and to rationalize the set-up to this speed. If a lower molar is placed buccally or lingually a millimeter in relationship to the approximating teeth, it is not necessary to correct. Not so with linear occlusion. The very simplicity of this occlusion sometimes defeats precision performance by the technician,. In looking at the occlusion, he over-simplifies it and fails to realize the geometric significance of a bilateral straight line contact in the occlusion. If one lower posterior is buccal or lingual even a half-millimeter to the intended straight line, a second dimension is immediately incorporated into the occlusion. The slightest deviation from onedimensional occlusion can cause postinsertion problems of soreness or looseness which the operator should immediately investigate and correct in the occlusion. Linear Contact There is no excuse for a laboratory technician not to understand why linear contact is so important and not to implement it in the set-up. However, the final control of this must be in the hands of the operator. This is ordinarily done when the finished dentures are delivered from the laboratory for insertion in the patient s mouth. The operator should take a lead pencil and mark the edge of the blade to check its accuracy; then, with carbon paper, the operator should be sure there is no other contact than the

blades when the patient slides from right to left. Protrusive balance is desirable, but not protrusive interference. It should be apparent by now that linear occlusion is simply a bilateral linear contact between the dentures when they occlude in the mouth. This bilateral linear contact must be maintained in right and left lateral excursions of the mandible into the parafunctional occlusion relationships. In a protrusive excursion, a balancing contact between the anterior teeth is permissible. This excludes any protrusive interference which would bring about a change in vertical opening in end to end relationship of the anterior teeth. This requirement to maintain onedimensional occlusion brings into focus the patient with a deep over-bite of the natural anterior teeth. with either two or three-dimensional occlusion. This opening is usually sufficient that in setting the anterior teeth, the technician can achieve a protrusive balance of the anterior teeth, the technician can achieve a protrusive balance of the anterior teeth by sacrificing very little in the length of either the upper or the lower anteriors. Vertical Dimension Linear occlusion works better without an over-bite in artificial denture. However, in view of the clinical experience to date, patients with a deep over-bite can be included in linear occlusion. It has been sufficiently demonstrated that patients with a deep over-bite can have vertical dimension increased to terminal phonetic closure. This vertical opening has been described in many ways. Silverman describes it as the closest speaking space. In any event, it is the vertical relationship of the anterior teeth at the spoken word six. This vertical dimension is noted by having the patient stand and then count to ten loudly. At the moment the patient pronounces the word six, the operator simply observes the vertical relationship of the anterior teeth and registers his centric relationship at this vertical. This can only be said of one-dimensional occlusion and should not be attempted