Inherent precision. Ru-106 Eye Applicators and I-125 Ophthalmic Seeds.

Similar documents
LDR Prostate Brachytherapy

Factory loaded, sterilized, ready to implant plaques:!

MultiSource. for a higher standard in HDR brachytherapy.

ROPES eye plaque dosimetry: commissioning and verification of an ophthalmic brachytherapy treatment planning system

Ophthalmic tumors. Wolfgang Sauerwein

Can Protons replace Eye Brachytherapy? 1 Department of Radiation Oncology

Method for verifying the air kerma strength of I-125 plaques for the treatment of ocular melanoma

Dosimetric Benefit of a New Ophthalmic Radiation Plaque

Optimisation of eye plaque dosimetry using Monte Carlo method. J. Green, D. Cutajar, S. Guatelli, & Rosenfeld, A.B.

NOVEL SOFTWARE MODULES FOR TREATMENT PLANNING OF 106 RU EYE PLAQUE BRACHYTHERAPY

Uveal Melanoma. Protocol applies to malignant melanoma of the uvea.

Semiflex 3D. Always perfectly oriented. 3D Thimble Ionization Chamber for Relative and Absolute Dosimetry

Dose to professionals in epiescleral brachytherapy

Seed coordinates of a new COMS-like 24 mm plaque verified using the FARO Edge

Semiflex 3D. Always perfectly oriented. 3D Thimble Ionization Chamber for Relative and Absolute Dosimetry

A REANALYSIS OF THE COLLABORATIVE OCULAR MELANOMA STUDY MEDIUM TUMOR TRIAL EYE PLAQUE DOSIMETRY

Three-dimensional dosimetry imaging of I-125 plaque for eye cancer treatment

Applications in brachytherapy

Humanity s Vision Is Our Focus. The Ahmed Glaucoma Valve

Radioactive sources in brachytherapy

A practical approach to estimating optic disc dose and macula dose without treatment planning in ocular brachytherapy using 125 I COMS plaques

Proton Radiation Therapy of Ocular Melanoma at PSI

Research Article Outcomes and Control Rates for I-125 Plaque Brachytherapy for Uveal Melanoma: A Community-Based Institutional Experience

Update on Intraocular Oncology

OUR EYES & HOW WE SEE

Plate/Valve Specifications: Thickness: 0.9mm Width: 13.00mm Length: 16.00mm Surface Area: mm 2

Retinoblastoma. Protocol applies to retinoblastoma only.

Dose distribution and dosimetry parameters calculation of MED3633 palladium-103 source in water phantom using MCNP

PRODUCTION ANIMAL AND EQUINE OPHTHALMOLOGY

2018 Council on Ionizing Radiation Measurements and Standards. Low Energy ( kev) Electron Beam Calibration. Gary Pageau

Episcleral plaque brachytherapy has been proposed as an

Intravascular Brachytherapy Dosimetry Techniques for Gamma systems

Absolute Dosimetry. Versatile solid and water phantoms. Introduction Introduction Introduction Introtro Intro Intro

Online Care, Online Control, Online Confidence

Vitreoretinal surgical management In ocular oncology

Unit VIII Problem 8 Anatomy: Orbit and Eyeball

Eye plaque dosimetry verification using novel solid state devices

National Guidelines for the management of uveal melanoma. Sponsored by Melanoma Focus

THE CHRONIC GLAUCOMAS

Let s share our talents

Outline. Brief history and principles of ophthalmic ultrasound. Types of ocular ultrasound. Examination techniques. Types of Ultrasound

An Interactive TreatmentPlanning System For Ophthalmic Plaque Radiotherapy

Test Bank for Medical Surgical Nursing An Integrated Approach 3rd Edition by White

Vision I. Steven McLoon Department of Neuroscience University of Minnesota

Lasers and Imaging PHOTOCOAGULATION PHOTODISRUPTION SLT PHOTOREGENERATION DIAGNOSTIC ULTRASOUND

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Dose Assessment of Eye and Its Components in Proton Therapy by Monte Carlo Method

OPPORTUNITIES IN BRACHYTHERAPY

An Injector s Guide to OZURDEX (dexamethasone intravitreal implant) 0.7 mg

Slide 1. Slide 2. Slide 3. Introduction of INTRABEAM IORT. Disclosure. Contents. I have nothing to disclose.

Monte Carlo simulation of 192 Ir radioactive source in a phantom designed for brachytherapy dosimetry and source position evaluation.

Advances in Ocular Imaging

XUE HUI Department of Histology& Embryology, Basic Medicine College of Jilin University

at the Leading Edge Cannulas 20 & 23 Gauge Instruments Vitreoretinal

Flexi-Needles. BMI_FLEXINEEDLES_v2 web

Glaucoma. Cornea. Iris

Retina Center of Oklahoma Sam S. Dahr, M.D. Adult Intraocular Tumors

Carlo Mosci. Ocular Oncology Service Galliera Hospital Genova Italy (

Standard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties

Brachytherapy Kits. BMI_BRACHYKITS_v17_ _web. Luer Lock Obturator Suture Holes Outer Catheter. Outer Catheter. Radioactive Seed.

Lasers and Imaging PHOTOCOAGULATION PHOTODISRUPTION SLT PHOTOREGENERATION DIAGNOSTIC ULTRASOUND

Dosimetric characteristics of 137 Cs sources used in after loading Selectron system by Monte Carlo method

Restoring Straumann implants. with Locator abutments.

Ocular Anatomy for the Paraoptometric

Texas Definition of Eye Exam. Definitions of Eye Examinations BILLING AND CODING: WHY IS THIS STUFF SO HARD? Optometry School Definition

Efficient Dosimetry for Proton Therapy

The Orbit. The Orbit OCULAR ANATOMY AND DISSECTION 9/25/2014. The eye is a 23 mm organ...how difficult can this be? Openings in the orbit

PROTON THERAPY. Proton Therapy Edition 2016 WORLD MARKET REPORT & DIRECTORY EDITION

4/22/16. Eye. External Anatomy of Eye. Accessory Structures. Bio 40B Dr. Kandula

THE SPECIAL SENSES. Introduction Vision

Calibration Standards

Custom Prosthetic Eyes

radiation monitoring programs Tailored to your needs

THE EYE: RETINA AND GLOBE

Tall, dark and.. Uh oh

A Guide to Administering

CLINICAL SCIENCES. Pretreatment Characteristics and Response to Plaque Radiation Therapy

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Transvitreal Fine Needle Aspiration Biopsy of Choroidal Melanoma via Pars Plana Vitrectomy

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Comparison of dosimetry parameters of two commercially available Iodine brachytherapy seeds using Monte Carlo calculations

Systemic and ocular follow-up after conservative management of an intraocular tumor

Calibration of Radiation Instruments Used in Radiation Protection and Radiotherapy in Malaysia

SHIELDING TECHNIQUES FOR CURRENT RADIATION THERAPY MODALITIES

There is one thing different. Everything.

Trina Lynd, M.S. Medical Physicist Lifefirst Imaging & Oncology Cullman, AL Tri-State Alabama, Louisiana and Mississippi Spring 2016 Meeting April

INTRODUCTION: ****************************************************************************************************

Episcleral eye plaque dosimetry comparison for the Eye Physics EP917 using Plaque Simulator and Monte Carlo simulation

Special Senses: The Eye

Technical Data Sheet SONOFLOW CO.55/xxx(H) V2.0

A Little Physics. How Does It Work? Radiation Therapy for Choroidal Neovascularisation in AMD A Review. => cell death

FEE RULES RADIATION ONCOLOGY FEE SCHEDULE CONTENTS

Continuing Medical Education

CYCLOTRONS WORLD MARKET REPORT & DIRECTORY EDITION TOC and Summary USED IN NUCLEAR MEDICINE MARKET DATA, COMPANIES PROFILES.

Sterile Consumables Catalogue

THE CHRONIC GLAUCOMAS

Assisting in Ophthalmology. Copyright 2011, 2007, 2003, 1999 by Saunders, an imprint of Elsevier Inc. All rights reserved.

SUMMARY OF PERSONAL DOSIMETRY PRACTICIES IN RCA MEMBER COUNTRIES

Sense of Vision. Chapter 8. The Eye and Vision. The Eye Orbit. Eyebrows, Eyelids, Eyelashes. Accessory Organs 5/3/2016.

Transcription:

Inherent precision Ru-106 Eye Applicators and I-125 Ophthalmic Seeds www.bebig.com

Brachytherapy for Eye Tumors Ophthalmic Brachytherapy The treatment of ocular tumors is selected according to the size and location of the lesion. Whenever possible, conservation of the eye and vision is attempted. In many centres, brachytherapy is the first choice of treatment for uveal melanomas. This modality is also useful for some retinoblastomas and conjunctival tumors. With this form of radiotherapy, a radioactive plaque containing ruthenium-106 or iodine-125 is sutured to the wall of the eye, adjacent to the tumor, and left in place for several days until the required dose of radiation has been delivered. Ciliary body Iris Retinal detachment Applicator (plaque) Uveal melanoma Retina Choroid Sclera Pupil Fovea centralis Cornea Lens Vitreous body Optic disc (blind spot) Optic nerve Example of tumor localization within the eye and positioning of an eye applicator Steps of Ophthalmic Brachytherapy 1 2 3 The conjunctiva is opened and the tumor is located by transillumination. The tumor margins and the intended location of the anterior plaque edge are marked on the sclera. If neccessary, any overlying extraocular muscles (red) are disinserted. The dummy plaque (template) is positioned according to the scleral ink-marks and sutured to the sclera by releasable sutures placed through the eyelets of the dummy. The position of the dummy in relation to the tumor is assessed by using a right-angled transilluminator while performing binocular indirect ophthalmoscopy. Once the dummy is well positioned, a mattress suture is inserted but left loose. The sutures are untied but left in place. The dummy is removed and replaced by the radioactive plaque, which is secured using the same sutures as the template. All sutures are fastened. Any dis-inserted rectus muscles are re-positioned and the conjunctiva is closed. 1

Ru-106 Eye Applicators First Choice Treatment with Ergonomic Design For more than 30 years, ophthalmologists have favored Ru-106 Eye Applicators due to their superior design and technical features. Owing to the long half-life of Ru-106, the applicators can be used multiple times over a one-year period. They require no assembly, just sterilization before use. Up to 50 cycles are permitted. With their slim design, they are particularly suitable for treating children. 16 types for individual tumor match Steep dose fall-off spares organs at risk Reusable for one year Provided by the only global supplier Silver window (0.1 mm) Ru-106 coated target foil (0.2 mm) Silver backing (0.7 mm) The radioactive core of the Ru-106 Eye Applicator consists of a foil coated with ruthenium-106 that decays with a half-life of 373.6 days via rhodium-106 to stable palladium. This core is safely encapsulated within pure silver sheets. The silver backing acts as a radiation shield and absorbs approximately 95 % of the beta radiation. Beneficial Beta Radiation Spares Organs at Risk The beta radiation emitted by Ru-106/Rh-106 has a maximum energy of 3.54 MeV resulting in an advantageous steep dose fall-off. The autoradiography clearly demonstrates that the dose distribution is ideal for treating tumors with a thickness of up to 5 mm. The gamma radiation emitted by Rh-106 contributes with about 1% only negligibly to the total dose in the target volume. Autoradiography by courtesy of Prof. Lommatzsch showing the charactaristic steep dose fall-off. As in most centres, the first choice for treating choroidal melanoma at the Liverpool Ocular Oncology Centre is brachytherapy. Ru-106 plaques have been used there since the service was established, in 1993, with excellent results. Ru-106 offers a particularly limited range of beta radiation, delivering a sufficient dose to the tumor while minimizing collateral damage to healthy parts of the eye. Prof. Bertil Damato is former president of ISOO, OOG and EVER. As an ophthalmic surgeon he specialized in the treatment of adult ocular tumors since 1984 and established the Ocular Oncology Service in Liverpool in 1993, leading it for 20 years. His main research interests relate to ocular melanoma and include the development of novel therapies, prognostication and quality of life studies. 2

Ru-106 Eye Applicators Availability of 16 Different Applicator Types The applicators are available in 16 different types to tailor the treatment to each individual tumor according to size and location. The plaques are curved, with a radius of 12 to 14 mm and have eyelets for suturing them to the sclera. The diameter of the applicators varies from 11.6 to 25.4 mm. Retinoblastoma Peripheral uveal/choroidal melanoma Tumors close to the optical nerve Ciliary body melanomas or melanomas close to the iris 16 types suggested for different tumor sites and sizes Dummies for Improved Accuracy Selection of transparent dummies: Damato Template and regular CIB Transparent or silver dummies help to improve the positioning of the Ru-106 Eye Applicators. They are available for all 16 versions of the plaque. The Damato Templates offer an additional feature: Four holes allow checking the position of the template with respect to the tumor by inserting the tip of a fine right-angled transilluminator through each hole and observing its location by indirect ophthalmoscopy. These special transparent dummies are available for the applicator types CCA, CCB and CCC. Selection of silver dummies: Type CIA and CCB 3

Ru-106 Eye Applicators Source Strength and NIST Traceable Dosimetry All plaques come with an extensive individual source certificate. The source strength is stated as the reference dose rate at the axis at a distance of 2 mm from the applicator surface. Its absolute calibration is traceable to the standard to the National Institute of Standards and Technology, USA (NIST). Safety and Sterilization Container This specialized container combines an aluminum insert and an outer stainless steel container for shielding of beta and gamma radiation. It facilitates safe and convenient steam sterilization and transportation of Ru-106 Eye Applicators within the clinic. Neither for the treatment room nor for the storage are any structural measures required. Steam sterilization Temp 134 C Pressure 3 bar Duration 3.5 min Dimensions Weight ca. 2.8 kg Height with lid 7.6 cm Total height with handle 19 cm Diameter 10 cm Eckert & Ziegler BEBIG: The ONLY Global Supplier for Ru-106 Eye Applicators Each single applicator is produced, tested and certified in Berlin, Germany, in compliance with high quality standards. Countries with Ru-106 centres 4

I-125 Ophthalmic Seeds and COMS Eye Applicators IsoSeed I25.S16 With a maximum photon energy of 35 kev, iodine-125 is suitable for treating medium and large uveal melanomas and retinoblastomas, with an apex height of up to 10 mm. IsoSeed I25.S16 is available in a wide range of apparent activities up to 25 mci, according to clinical requirements. The number and location of seeds on each plaque can be adjusted to tailor the dosimetry to each individual tumor. They can be reused for up to 6 months, depending on the activity. Treatment of even medium and large tumors For use with COMS or individual applicators I-125 as silver iodide within porous ceramic Titanium capsule Marker Ø 0.8 mm 4.5 mm IsoSeed I25.S16 details COMS Applicators For application, IsoSeed I25.S16 can be inserted via silicone inserts into COMS Plaque Shells, both available from Eckert & Ziegler BEBIG in different sizes. After steam sterilization, the individually assembled COMS Applicator is ready for use. Silicone COMS insert allows for reproducible seed positioning. COMS Plaque Shell made of a gold alloy that serves as carrier and shield. Calibration Traceable to PTB The certified source strength is based on air kerma measurement of IsoSeed which are traceable to the primary standard of the National Metrology Institute of Ger many PTB (Physikalisch-Technische Bundesanstalt). Along with the NIST (National Institute of Standards and Technology), the PTB is a member of the Mutual Recognition Agreement. IsoSeed I25.S16 is also suitable for other ophthalmic seed applicators. 5

Comparison of Ru-106 and I-125 Applicators Dosimetric Comparison A plot of the 2D dose distributions clearly shows the differences between Ru-106 and I-125 plaques. In their publication, Wilkinson et al.* demonstrate that for the treatment of thin melanoma Ru-106 plaques generally deliver the dose to a smaller volume and with less side-scatter than I-125 plaques of the same size. In addition, for a given tumor, treatment modeling with a Ru-106 plaque gives statistically significant smaller doses to the optic disc and macula. This is advantageous when assessing the risks for radiation retinopathy and radiation optic neuropathy. * The British Journal of Radiology, 81 (2008), Comparison of Ru-106 and I-125 plaques for treatment of shallow choroidal melanoma lesions, Wilkinson DA, Kolar M, Fleming PA, Singh AD. Comparison of the 2D dose distributions of two plaques with 18 mm diameter. Both planned with a dose of 85 Gy to the apex of a thin tumor. I-125 shown on the left and Ru-106 on the right. Individual Advantages of Ru-106 and I-125 The graph of the dose-depth curves of Ru-106 and I-125 plaques of similar size clearly shows the individual advantages of the two nuclides. Ru-106 is characterized by a particularly steep dose fall-off, which allows delivery of a sufficient dose to the tumor while effectively sparing adjacent healthy tissue. Beyond a tumor thickness of 5 mm, I-125 provides a sclera dose within well-accepted limits. Dose on sclera (Gy) 1000 500 Ru-106 apex 5 mm I-125 apex 5 mm I-125 apex 7 mm Ru-106 apex 7 mm 85 Gy at tumor apex 85 0 5 7 Apex height (mm) Dose depth curves for Ru-106 and I-125 plaques of similar sizes (CCB and COMS Ø20 mm). The solid lines illustrate the situation for a tumor with 5 or 7 mm apex height. The dashed line shows the theoretical values for a treatment with Ru-106 beyond 5 mm tumor thickness. 6

Eckert & Ziegler BEBIG Today Eckert & Ziegler BEBIG is a European-based group active in the medical device segment of the health care industry. Its core business is the production and distribution of medical products for the treatment of cancer using brachytherapy.the company headquarters are in Belgium, with production facilities in Germany and in the USA, as well as subsidiaries throughout Europe, the USA and Brazil. In addition, Eckert & Ziegler BEBIG has a worldwide network of distributors and agents to support the international marketing and distribution of its product line. The company s products and equipment are intended for use by oncologists, radiotherapists, urologists, ophthalmologists and medical physicists. Eckert & Ziegler BEBIG employs approximately 130 people. The company has been listed on the Euronext stock exchange since April 1997. DISTRIBUTION 1 2 3 4 5 6 7 Mount Vernon, NY, USA Fortaleza, Brazil Didcot, Great Britain Seneffe, Belgium Paris, France Madrid, Spain Berlin, Germany PRODUCTION 1 2 Corporate Head Office: Manufacturer: Eckert & Ziegler BEBIG SA Eckert & Ziegler BEBIG GmbH Rue Jules Bordet Zone Industrielle C 7180 Seneffe Belgium Phone +32 64 520 811 Fax +32 64 520 801 Robert-Rössle-Str. 10 Mount Vernon, NY, USA Berlin, Germany 13125 Berlin Germany Phone +49 30 94 10 84 130 Fax +49 30 94 10 84 112 Regional Sales, Marketing and Service: Europe, Middle East, Africa, Latin America, Asia Pacific North America Eckert & Ziegler BEBIG SA Mick Radio-Nuclear Instruments, Inc. An Eckert & Ziegler BEBIG Company Rue Jules Bordet Zone Industrielle C 7180 Seneffe Belgium Phone +32 64 520 811 Fax +32 64 520 801 521 Homestead Avenue Mount Vernon, NY 10550 USA Phone +1 914 667 3999 Fax +1 914 665 8834 www.bebig.com info@bebig.com www.micknuclear.com The mentioned products are not available in all markets. Please contact your local Eckert & Ziegler BEBIG representative for more information. P13D140/Rev. 05/08.2017