New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

Similar documents
New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

Enhanced LC-MS Sensitivity of Vitamin D Assay by Selection of Appropriate Mobile Phase

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

Impurity Profiling of Carbamazepine by HPLC/UV

High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine

LC-MS/MS Method for the Determination of Tenofovir from Plasma

Bioanalytical Quantitation of Biotherapeutics Using Intact Protein vs. Proteolytic Peptides by LC-HR/AM on a Q Exactive MS

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

Comparison of Full Scan MS2 and MS3 Linear Ion Trap Approaches for Quantitation of Vitamin D

The Investigation of Factors Contributing to Immunosuppressant Drugs Response Variability in LC-MS/MS Analysis

GC-MS/MS Analysis of Benzodiazepines Using Analyte Protectants

Identification and Quantitation of Microcystins by Targeted Full-Scan LC-MS/MS

ApplicationNOTE EXACT MASS MEASUREMENT OF ACTIVE COMPONENTS OF TRADITIONAL HERBAL MEDICINES BY ORTHOGONAL ACCELERATION TIME-OF-FLIGHT.

Evaluation of an LC-MS/MS Research Method for the Analysis of 33 Benzodiazepines and their Metabolites

Increased Identification Coverage and Throughput for Complex Lipidomes

Providing a Universal, One-step Alternative to Liquid-Liquid Extraction in Bioanalysis

ApplicationNOTE A MULTI-RESIDUE LC/MS/MS METHOD FOR THE DETERMINATION OF 81 PESTICIDE RESIDUES IN FRUIT AND VEGETABLES: PART 1, METHOD OVERVIEW

[ Care and Use Manual ]

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

Quantitative Analysis of THC and Main Metabolites in Whole Blood Using Tandem Mass Spectrometry and Automated Online Sample Preparation

Results of Using Re-washed Vials and Closures

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

Agilent 7700x ICP-MS

LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine

Rapid and Direct Analysis of Free Phytosterols by Reversed Phase HPLC with Electrochemical Detection

Detection of oxygenated polycyclic aromatic hydrocarbons (oxy-pahs) in APCI mode with a single quadrupole mass spectrometer

Dry eye disease commonly known as atopic keratoconjunctivitis is an autoimmune disease of

Using Multiple Mass Defect Filters and Higher Energy Collisional Dissociation on an LTQ Orbitrap XL for Fast, Sensitive and Accurate Metabolite ID

Use of a Tandem Mass Spectrometry Research Method for the Analysis of Amino Acids and Acylcarnitines in Dried Blood Spots

Using Software Tools to Improve the Detection of Impurities by LC/MS. Application Note. Christine Miller Agilent Technologies.

Thermo Fisher Scientific, Sunnyvale, CA, USA; 2 Thermo Fisher Scientific, San Jose, CA, USA

A Rapid UHPLC Method for the Analysis of Biogenic Amines and Metabolites in Microdialysis Samples

More structural information with MS n

Measuring Phytosterols in Health Supplements by LC/MS. Marcus Miller and William Schnute Thermo Fisher Scientific, San Jose, CA, USA

Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 1290 Infinity II/6230B LC/TOF system

Mass Spectrometry. Actual Instrumentation

Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices

Identification of Steroids in Water by Ion Trap LC/MS/MS Application

Determination of Clinically Relevant Compounds using HPLC and Electrochemical Detection with a Boron-Doped Diamond Electrode

Core-Shell Technology for Proteins and Peptides

Bio-Rad Laboratories. Hemoglobin Testing. VARIANT II Hemoglobin Testing System For HbA 1c

PosterREPRINT INTRODUCTION. 2-D PAGE of Mouse Liver Samples. 2-D PAGE of E.coli Samples. Digestion / Cleanup. EXPERIMENTAL 1-D PAGE of BSA Samples

Characterization of an Unknown Compound Using the LTQ Orbitrap

ACQUITY UPLC WITH PDA DETECTION: DETERMINING THE SENSITIVITY LIMITS OF OXYBUTYNIN AND RELATED COMPOUNDS

Protect Your Mass Spec

Dayana Argoti, Kerry Hassell, Sarah J. Fair, and Joseph Herman Thermo Fisher Scientific, Franklin, MA, USA

Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System

Uptake and Metabolism of Phthalate Esters by Edible Plants

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis

Probing for Packaging Migrants in a Pharmaceutical Impurities Assay Using UHPLC with UV and Mass Detection INTRODUCTION

Improved Extraction and Analysis of Hexavalent Chromium from Soil and Water

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit

Identification and Quantification at ppb Levels of Common Cations and Amines by IC-MS

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

IC-MS Environmental Applications - Water Testing. Application Notebook

Nitrogen/Protein Determination in Starch by Flash Combustion using Large Sample Weight as an Alternative to the Kjeldahl Method

Applying a Novel Glycan Tagging Reagent, RapiFluor-MS, and an Integrated UPLC-FLR/QTof MS System for Low Abundant N-Glycan Analysis

Vitamin D3 and related compounds by ESI and APCI

Fast and easy separation of 23 drugs of abuse. including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS

Quantitative Analysis of Drugs of Abuse in Urine using UHPLC Coupled to Accurate Mass AxION 2 TOF Mass Spectrometer

Integrated Targeted Quantitation Method for Insulin and its Therapeutic Analogs

Analysis of Isoflavones with the PerkinElmer Flexar FX-15 UHPLC System Equipped with a PDA Detector

LC-MS/MS quantitative analysis of Polyunsaturated Omega 3, 6,7 and 9 Fatty Acids in Serum for

International Journal of Applied Pharmaceutical Sciences and Research

LCMS-8030 Application Report. Steroids: Testosterone, Progesterone, Estradiol, Ethinylestradiol

LC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell 120 EC C18 Column

Edgar Naegele. Abstract

Ensuring High Sensitivity and Consistent Response in UHPLC-MS Analyses

Improving Food Process Control Using the

Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Steviol Glycosides from Stevia rebaudiana Bertoni

2D-LC as an Automated Desalting Tool for MSD Analysis

Mercury Speciation Determinations in Asian Dietary Supplements

APPLICATIONS Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns

Thermo Scientific LipidSearch Software for Lipidomics Workflows. Automated Identification and Relative. Quantitation of Lipids by LC/MS

A New Era in SFC Column Technology

Sample Concentration and Analysis of Human Hormones in Drinking Water

Detection and Quantification of Inorganic Arsenic in Fruit Juices by Capillary Ion Chromatography with Suppressed Conductivity Detection

The first and only fully-automated, multiplexed solution for Measles, Mumps, Rubella and Varicella-zoster virus antibody testing

Lipidomic Analysis by UPLC-QTOF MS

LC-MS/MS analysis of Chlorates in Milk and Whey Powder using the Agilent 6470 QQQ

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages

Title: Pharmacokinetics of daikenchuto, a traditional Japanese medicine (Kampo) after. single oral administration to healthy Japanese volunteers

Determination of Amantadine Residues in Chicken by LCMS-8040

application Natural Food Colorants Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS

Dynamic Analysis of HIV-Human Protein-Protein Interactions During Infection

Introduction to LC/MS/MS

APPLICATIONS TN Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology.

Analysis of the Non-Ionic Surfactant Triton-X Using UltraPerformance Convergence Chromatography (UPC 2 ) with MS and UV Detection

Authors. Abstract. Introduction. Environmental

FT-Raman Surface Mapping of Remineralized Artificial Dental Caries

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1

Small Scale Preparative Isolation of Corticosteroid Degradation Products Using Mass-Based Fraction Collection Application

About bioassay of Oximes:? New isolation alternatives from biomatrices? Chromatographic separation issues? Reserve on using MS or MS/MS detection

Comprehensive Two-Dimensional HPLC and Informative Data Processing for Pharmaceuticals and Lipids

PIF: Precursor Ion Fingerprinting Searching for a Structurally Diagnostic Fragment Using Combined Targeted and Data Dependent MS n

Core E Analysis of Neutral Lipids from Human Plasma June 4, 2010 Thomas J. Leiker and Robert M. Barkley

Transcription:

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS Subhra Bhattacharya, Deva H. Puranam, and Stephen C. Roemer Thermo Fisher Scientific Fisher Chemical, One Reagent Lane, Fair Lawn, NJ

Material and Methods Fisher Chemical has developed a new solvent grade, UHPLC-MS Optima, for mobile phases targeting trace analysis by UHPLC-MS. These ultra-pure solvents will provide a very low mass noise level in both positive and negative mode ionization, minimal metal ion content, and very low UHPLC- UV response using photo diode array detection. Fisher Chemical s high purity solvents are specifically qualified for UHPLC-MS and offered in Acetonitrile, Methanol, and Water. Solvent Pack size Packaging Catalog Number Acetonitrile 1L Borosilicate Glass A956-1 Methanol 1L Borosilicate Glass A458-1 Water 1L Borosilicate Glass W8-1 Introduction Ultra-high performance liquid chromatography (UHPLC) is associated with submicron particle size column and high pressure flow resulting in increased resolution and sensitivity for complex sample mixtures and increased speed of analysis. Mass spectrometry (MS) enables the detection and identification of analytes at the parts per trillion level. UHPLC coupled with MS (UHPLC- MS) is a powerful tool in analytical chemistry that requires mobile phase solutions prepared with exceptionally pure solvents permitting trace analysis. UHPLC-MS Optima, the new Fisher Chemical solvent grade for mobile phases targeting UHPLC-MS will show a very low mass noise level in both positive and negative mode ionization, minimal metal ion content, and very low UHPLC-UV response using photodiode array detection. Mobile phase: acetonitrile (ACN), methanol, and water were evaluated; all three solvents are from a new grade, Optima UHPLC-MS, that will provide very low mass noise level in both positive and negative mode ionization. Instrument: Thermo Scientific Accela UHPLC system comprised of an auto-sampler, photodiode array detector, and attached to an LTQ-XL mass spectrometer equipped with an electro-spray ionization interface. Column: Thermo Scientific Hypersil GoldTM column (50 mm x 2.1 mm, 1.9 micron), Catalog No: 26-102-052130. Standards: propazine (SPEX CertiPrep, S-3170,1000 μg/ml) as the positive mode standard and chloramphenicol (SPEX CertiPrep, S-4032, 1000 μg/ml) as negative mode standard. These standards provided adequate ionization without any additive applied to the mobile phase. ESI-MS from 100 to 1500 amu. The collision induced dissociation (CID) mass spectra were obtained with helium as the collision gas after isolation of the particular precursor ion. Other parameters including gas flow and capillary voltage were adjusted as required. HPLC Gradient: 0 0.5 min: 90% water, 10% ACN 0.5 min 2.0 min: 0% water, 100% ACN 2 min 5 min: 100% ACN Post run 5.1 min 10 min: 90% water, 10% ACN Flow rate: 0.6 ml/min for water/acn, 0.5 ml/ min for water/methanol Injection volume: 5 μl Propazine Chloramphenicol (M+H) + = 230.11 (M-H) - = 321.01 2

Results linking UHPLC-MS sensitivity to trace analysis of positive and negative mode standards (Figs. 1 10). (Figs. 3 6) and chloramphenicol as negative mode standard (Figs. 7 10) in order to assess interfering baseline peaks in both full scan ESI- MS and CID generated product ions. Figure 1. Blank Gradient of PDA, UV and TIC Figure 2. Blank Gradient of PDA, UV and TIC Figure 3. Serial Dilution of Propazine EIC of m/z 230 Figure 4. Mass Spectra of m/z 230 Propazine Peak (250 pg) Figure 5. MS/MS of Propazine From Serial Dilution 3

Figure 6. MS/MS Spectra of Propazine in Two Different Solvent Systems Figure 7. Serial Dilution of Chloramphenicol Figure 8. Mass Spectra of Chloramphenicol in and Figure 9. MS/MS of Chloramphenicol in and Gradient Figure 10. MS/MS Spectra of Chloramphenicol 4

Discussion water/methanol in PDA, UV and mass spectra is shown in Figs. 1 and 2. No extraneous peaks were observed in either solvent system. was detected in positive mode ionization both in water/acn and water/methanol gradient by EIC after full scale data acquisition (100 1500 amu). The signal to noise ratio of the peak was observed below the level of quantitation (LOQ) in the ACN gradient. However, a 25 pg/μl concentration (25 ppb) of propazine showed S/N >10 in both solvent systems (Fig. 3). accomplished using 250 fg/μl (250 ppt) of analyte, and the signal to noise ratio of the m/z 188 product ion was monitored. For both solvent systems, the propazine product ion showed S/N >30 (Figs. 5 and 6) which is consistent with the detection sensitivity of the LTQ-XL ion trap mass spectrometer. of chloramphenicol showed S/N >10 in the solvent systems showed m/z 435 due to TFA (m/z 113) adduct formation coming from the system (Fig. 8). generated the product ion of m/z 257 with a S/N >10 (Figs. 9 and 10). Conclusions UHPLC-MS mobile phase solvents, trace amounts of propazine and chloramphenicol standards showed significant peak height without interfering background peaks in both full scan ESI-MS and CID generated product ions. common practice for evaluating MS sensitivity, and we have developed a similar approach to assess the purity of mobile phase solvents. peak of m/z 188 with a signal to noise ratio >30 at 250 ppt using a water/acetonitrile mobile phase. 5

To place an order, contact your local Fisher Scientific office. 2014 Thermo Fisher Scientifi c Inc. All rights reserved. All other trademarks are the property of Thermo Fisher Scientifi c Inc. and its subsidiaries. AMERICAS Canada Fisher Scientific Canada www.fishersci.ca Tel: 800-234-7437 Fax: 800-463-2996 EUROPE Austria info.austria@thermofisher.com www.at.fishersci.com Tel: 0800 20 88 40 Fax: 0800 20 66 90 Germany info.germany@thermofisher.com www.de.fishersci.com Tel: 2304 932-5 Fax: 2304 932-950 Portugal pt.fisher@thermofisher.com www.pt.fishersci.com Tel: 21 425 33 50 Fax: 21 425 33 51 ASIA India lsi_marketing @thermofisher.com www.fishersci.in Tel: +91-22-6680 3000 Fax: +91-22-6680 3001 OCEANIA Australia AUinfo@thermofisher.com www.thermofisher.com.au Tel: 1300-735-292 Fax: 1800-067-639 14_2054 LW/JG 11/14 BN1118143 4 Latin America Fisher Scientific Global Export, Latin America www.fishersci.com Tel: 770-871-4725 Fax: 770-871-4726 Belgium be.fisher@thermofisher.com www.be.fishersci.com Tel: 056 260 260 Fax: 056 260 270 Ireland fsie.sales@thermofisher.com www.ie.fishersci.com Tel: 01 885 5854 Fax: 01 899 1855 Spain es.fisher@thermofisher.com www.es.fishersci.com Tel: 902 239 303 Fax: 902 239 404 Korea sales.fsk@thermofisher.com www.fishersci.co.kr Tel: 02-3420-8700 Fax: 02-3420-8710 New Zealand NZinfo@thermofisher.com www.thermofisher.co.nz Tel: 0800-933-966 Fax: +64 9 980 6788 United States Fisher HealthCare www.fisherhealthcare.com Tel: 800-640-0640 Fax: 800-290-0290 Czech Republic info.cz@thermofisher.com www.thermofisher.cz Tel: 466 798 230 Fax: 466 435 008 Italy it.fisher@thermofisher.com www.it.fishersci.com Tel: 02 950 59 478 Fax: 02 950 59 479 Sweden fisher.se@thermofisher.com www.se.fishersci.com Tel: 31 352 32 00 Fax: 31 352 32 50 Malaysia enquiry.my@thermofisher.com www.fishersci.com.my Tel: (603) 51228888 Fax: (603) 5121 8899 Fisher Scientific www.fishersci.com Tel: 800-766-7000 Fax: 800-926-1166 Denmark kundeservice@thermofisher.com www.dk.fishersci.com Tel: 70 27 99 20 Fax: 70 27 99 29 Lithuania sales.lt@thermofisher.com www.lt.fishersci.com T: +370 5 2444442 F: +370 5 2392756 Switzerland info.ch@thermofisher.com www.ch.fishersci.com Tel: 056 618 41 11 Fax: 056 618 41 41 Singapore enquiry.sg@thermofisher.com www.fishersci.com.sg Tel: (65) 6873 6006 Fax: (65) 6873 5005 Finland fisher.fi@thermofisher.com www.fi.fishersci.com Tel: 09-802 76 280 Fax: 09-802 76 235 The Netherlands nl.info@thermofisher.com www.nl.fishersci.com Tel: 020 487 70 00 Fax: 020 487 70 70 United Kingdom fsuk.sales@thermofisher.com www.fisher.co.uk Tel: 01509 555500 Fax: 01509 555111 France fr.fisher@thermofisher.com www.fr.fishersci.com Tel: 03 88 67 14 14 Fax: 03 88 67 11 68 Norway fisher.no@thermofisher.com www.no.fishersci.com Tel: 22 95 59 59 Fax: 22 95 59 40