Why Choose OriGen? Mission Statement: We create medical products which improve peoples lives.

Similar documents
MAKE THE CLEAR CHOICE. IV Products and Accessories Designed to Help Maximize Clinical Performance While Optimizing Savings

Isn t it worth two bags?

Better Post-Op Pain Control Starts Here

Helping to protect you from exposure to hazardous drugs

Education for Self Administration of Intravenous Therapy HOME IV THERAPY PICC. Portacath

Flexi-Needles. BMI_FLEXINEEDLES_v2 web

CATHETER ACCESS KIT. For use with Prometra Programmable Infusion Systems

Exacta EXTERNAL DRAINAGE AND MONITORING SYSTEM

Irrigation systems PRODUCT CATALOG

Graft Delivery Devices

DISCOVER NEW HORIZONS IN FLUID DRAINAGE. Bringing Safety and Convenience to Fluid Drainage Management

Brachytherapy Kits. BMI_BRACHYKITS_v17_ _web. Luer Lock Obturator Suture Holes Outer Catheter. Outer Catheter. Radioactive Seed.

Exacta EXTERNAL DRAINAGE AND MONITORING SYSTEM

User Bulletin 7500 Fast Precision Plate Holder for MicroAmp Tube Strips

DRAINAGE. MeritEMEA.com

Cardioplegia Circuit Products { CARDIOPLEGIA ADAPTERS}

Integra Flowable Wound Matrix

Becker external drainage and monitoring system

CryoStor CS2, CS5 and CS10 FREEZE MEDIA

OTAGO LIPOSURG. Compact, powerful system for infiltration and liposuction

Tropic plus ultrasonic nebulizer Consumables and Accessories

* CDC (Central Disease Control, USA) Guideline 2011* recommends using transparent and split septum designed needle free valves.

EQUASHIELD II Closed System. Technical Spe. FDA cleared under ONB product code and substantiated to prevent microbial ingress up to 7 days

Fluid Mgmt. Manifolds - Fluid Management. Product Code Description Units Per Box

Content: About Seaforia. Introduction Seaforia Sperm Seaparation System Seaforia procedure Seaforia Disposable Kit Seaforia Lab Kit.

Y s A P. n n. C o. e c. t o r s E R. e s. e l. e e d l I V. e d o s C l. vadsite The Transparent, Split Septum, Needleless Connector

RealLine Mycoplasma genitalium Str-Format

Galt Medical Corp. A leader in vascular and interventional medical devices. part of the GaltNeedleTech TM Family

AMSure UROLOGICAL CARE

Boehringer Ingelheim BioXcellence. Producing Value. Global Contract Manufacturing Excellence

For accurate and easy urine measurement

Consumer Health Care V5.0_2013

COST, PROCESS & QUALITY IMPROVEMENT

Quick Sealing with a Twist to Connect Actuation Method

Sterile Consumables Catalogue

Volumetric Infusion Pumps INFUSIONMANAGEMENT

DUAL CHAMBER SYSTEMS

Innovations in Administration and Injection Systems EXPERIENCED CREATIVE FOCUSED

Seaforia Sperm Separation System. Product Catalog

Human Umbilical Cord Blood CD34 + /133+ Progenitor Cell Care Manual

CLICK SEAL SYSTEM. Thermo Scientific Samco Clicktainer Vial. Unique click seal system providing sample protection and user safety

Solutions for Urological Care

Partner with the Global Leader in Drug Delivery Systems.

Micro Production Part.

Stratis INSTRUCTIONS FOR USE. Needle-free Injection System. 0.5mL volume (+/-5%)

Sharps Safety. Product Catalog. Needle-Pro EDGE Safety Needles and Syringe Combinations. Arterial Blood Sampling Kits

Clinical Conference, continued

BMI Medical. Ventricular Catheter T

AN INTRODUCTION TO YPSODOSE FOR THE LARGE-VOLUME INJECTION OF BIOLOGICS

Veterinary Products Catalog. I.V. Catheters Needles Syringes Winged Infusion Sets

RealLine HIV quantitative Str-Format

LG MEDIA & GPS DISHWARE CODA AIR

ASEPT System ASEPT Pleural/Peritoneal. ASEPT Drainage Kits (600 ml ml) Accessories. Quality and Experience

Rapid-VIDITEST Swine Flu

IMPORTANT DRUG INFORMATION

Solutions Urological Care

THE FLOCARE RANGE OF ENTERAL FEEDING PUMPS, TUBES AND ACCESSORIES

Original Pump Disposables

PORTO 2 VENT CPAP OS. Operator s Manual. PORTO 2VENT CPAP OS System Operator s Manual Part Number Rev I

Partner with the Global Leader in Drug Delivery Systems.

ASEPT. Pleural Drainage System INSTRUCTIONS FOR USE REF LOT STERILE EO. Manufactured for: 824 Twelfth Avenue Bethlehem, PA

MICAFUNGIN MIXING

Kiwa Inspecta. Kiwa Inspecta. Trust Quality Progress

BD UnijectTM Auto-disable Prefillable Injection System Bridging the Gap

CLICK SEAL SYSTEM. Thermo Scientific Samco Clicktainer Vial. Unique click seal system providing sample protection and user safety

experiences that matter

Standard Operating Procedure for cannulation

Enteral nutrition safely PEDIATRICS

SYMBOLOGY. = Manufacturer. = Manufacturing Serial Number. = Manufacturing Lot Number = Catalog Number LOT REF. = Do not resterilize Single Use Only

BROEN UNIFLEX FITTINGS FOR NON-BURNING 2.0 GASES / VACUUM

Amigo Surgi-care Pvt. Ltd.

Driving performance, delivering versatility. Spetzler -Malis and SILVERGlide Non-Stick Bipolar Forceps

Let s share our talents

BODY FLUID TREATMENT

with ENFit compatible connectors Enteral Syringes & Accessories PRODUCT GUIDE & ORDER CODES

DORO. NON-STICK Bipolar Forceps. DORO Simply Better Built Simply More Choices.

RealLine HCV Qualitative Str-Format

VENTILATOR PRODUCT ACCESSORIES CATALOG

URGENT: Important Safety Information

Instruction for use of Foley Catheter

Mouse Hepatic Progenitor Organoid Culture: Supplementary Protocols

LINEAR. 7.5Fr. IAB Catheter. This document is intended to provide information to an international audience outside of the US.

Specialty Sterilization Service

21in Heavy-Duty Recycler /Rear Bagger Lawn Mower

Autotitrator. Technical Information and Specifications. mpt-2. detailed specification sheets from

FINE INSTRUMENTS AND EQUIPMENT FOR LIPOPLASTY

Sodium Chloride 0.9% Injection, FK Std.

Dynarex Introduces New ENFit Connectors in accordance with the FDA Your Medical Products Partner

Plastic Storage Bottles. Product Selection Guide

Course Syllabus National College of Midwifery /2017

RealLine HIV qualitative Str-Format

ASEPT Pleural Drainage System

NEPHROCHECK Calibration Verification Kit Package Insert

ASEPT. Pleural Drainage System INSTRUCTIONS FOR USE. Rx only REF LOT. STERILE EO Sterilized using ethylene oxide

Beaver-Visitec International. Ophthalmic and Microsurgical Product Catalog

Quantity in. Unit of Measure. (If Applicable) 1 each Anode Buffer Reservoir Jar 1 Applied Biosystems $101.65

Volumetric Infusion Pumps - Delivering Volume with Accuracy

Preparation Instructions for the CAMLOG /CONELOG Implant System

This document is a preview generated by EVS

Transcription:

Accessory Catalog

S-FFP12 Mission Statement: We create medical products which improve peoples lives. Why Choose OriGen? Quality Commitment quality is the foundation of all product design at OriGen, and each product is produced with the intention that it will improve patient health. OriGen is certified annually to ISO13485 standards, and regularly inspected by the FDA, ISO-certification organizations, and our customers. We maintain worldwide certifications to cgmps and our products are registered with regulatory agencies across the world. RF-T15 er Commitment We offer superior products and real customer service. We listen to our customers and work with them to develop products that meet their needs. OriGen is not just another supplier; we are a partner committed to providing you with solutions tailored to your specific needs. As an OriGen customer, you can be sure that the same attention to detail has gone into every product with the OriGen label. Design Commitment We strive to find product solutions to make your operations more intuitive, safer, and more efficient. OriGen s engineers will work with you to develop products that fit your lab practices, not make you change your practices to fit the products. CC2 VSV OriGen accessory sets are intended to streamline cell processing; adapting to your process rather than the other way around. If you do not see what you need included in this catalog, custom product design is available. Contact your sales representative or our main office at +1 (512) 474-7278 and we will begin the development process. Please note: This catalog contains both stock and custom products. products have an 8-12 week lead time and minimum quantities may apply. The symbol (*) appears throughout the catalog and indicates 100% DMSO resistance. Tube lengths may be shortened to show component detail. Images are not to scale.

Sterile Access Bag & vial spikes for accessing OriGen products including CryoStore TM freezing and Permalife TM cell culture bags and CryoPur TM DMSO vials. Individual sterilized caps are also available for use with OriGen bags and accessory sets. Sterile Access CBS* One spike with needle-free valve Stock 50 IBS One spike with needle injection site Stock 50 CBS VSV* Vial spike with needle-free valve Stock 10 VSV NFV* Needle-free valve with caps Stock 10 PC2 PC2 Protective cap for female luer 100 NFV PC3 Knob style, non-vented cap for male luer 100 PC3

Spike Adapters Spike Adapters Tube sets with spikes that provide access to CryoStore bags and OriGen bag spike ports. S-FFP12 One spike to one spike port and two female luers with 12cm SCD tubing and pinch Stock 20 S-FFP12 2P-S16 2P-S16 Two spike ports to one spike with 16cm SCD tubing 20 2S-P20 2S-P20 Two spikes to one spike port with Stock 20 20cm SCD tubing and pinch 2S-M20 2S-S30 Two spikes to one male luer with 20cm SCD tubing and pinch Two spikes to one spike with 30cm SCD tubing and pinch 20 20 S-38B12 S-38B12* One spike to one 3/8 barb with 12cm tubing Stock 25

Spike Adapters Tube sets with spikes that provide access to CryoStore bags and OriGen bag spike ports. S-S3 One spike to one spike with 3cm of SCD tubing 50 S-S10 S-S50 20-SKS One spike to one spike with 10cm of SCD tubing and pinch clamp One spike to one spike with 50cm of SCD tubing and pinch clamp One spike to one spike with 20cm of SCD tubing, a pinch clamp and a stopcock 50 50 25 S-S10 Spike Adapters S-F10* One spike to one female luer with 10cm of tubing and pinch clamp Stock 50 20-SKS S-F50 F-S12 One spike to one female luer with 50cm of SCD tubing and pinch clamp One spike to one female luer with 12cm SCD tubing Stock 50 50 S-F10 150-S-M One spike to one male luer with 150cm SCD tubing and roller clamp 50 S-M10* S-M50 One spike to one male luer with 10cm of tubing and pinch clamp One spike to one male luer with 50cm SCD tubing and pinch clamp Stock 50 Stock 50 S-M10 S-M50C* One spike to one male luer with 50cm tubing and pinch clamp 50 S-M* One spike to one male luer 50 SU-M50 One spike to one male luer with 50cm SCD tubing and roller clamp 50

Tube Adapters Provide a quick connection or bridge between items being processed Tube Adapters 10-F-M 10-F-M* One male leur to one female luer with 10cm tubing and pinch clamp 50 12-F-M* 15-F-T One female luer to one male luer with 12cm tubing One female leur with 15cm of SCD tubing sealed at the end 50 50 2M-F17 2M-F17* Two male luers to one female luer with 17cm of tubing 20 2M-M17* Two male luers to one male luer with 17cm of tubing 20 Dv-M80 Dv-M80 One vented drip chamber to one male luer with 80cm SCD tubing and a pinch clamp 50

Sterile Syringes Provide sterile sampling for testing biologics and transfer between laboratories RF-T15 6ml syringe on a female luer with 15cm sealed SCD tubing Stock 25 R3F-T15 3ml syringe on a female luer with 15cm sealed SCD tubing Stock 25 RF-T15 R12-C 12ml syringe, double aseptically pouched 12 R60-CS 60ml syringe with a cap, double aseptically pouched 20 15-RF60-T 60ml syringe on a female luer with 15cm sealed SCD tubing 25 RV-T15 6ml syringe on a needle-free valve 25 with 15cm SCD tubing (tubing is plugged with a breathable vent) RV50-T15 60ml syringe on a needle free valve with 15cm SCD tubing (tubing is plugged with a breathable vent) 20 RV-T15 Sterile Syringes

Manifold Sets Manifold sets are tube sets with multiple terminals and adapters that minimize product handling and streamline cellular processing 3S-T100 3S-T100 Three spikes to sealed tubing with 100cm of SCD tubing and pinch 12 Manifold Sets 40-S-V-SMM 40-S-V-SMM* One spike to a needle-free valve to one spike and two male luers with 40cm tubing and roller. 100% DMSO resistant below the needle-free valve 20 4S-4M60 4S-4M60 Four spikes to four male luers with 60cm SCD tubing, roller and pinch Stock 12

Cell Connect TM The Cell Connect TM is designed to streamline the addition of hematopoietic stem cells and freezing solution into up to four CryoStore TM freezing bags to process for cryopreservation. CC1 Two spikes to a 3-way stopcock, 60ml syringe and needle-free valve to four male luer with SCD tubing and pinch Stock 12 CC2 One spike and one male luer to a 3-way stopcock, 60ml syringe and needle-free valve to four male luers with SCD tubing and pinch Stock 12 CC1 CC35-5MT 5 male luers with pinch. Intended as an add-on to CC1 or CC2 via sterile dock to create 5 additional terminals for a total of 8 SCD connections for Cryostore TM bag filling 12 A B Example of use: Close all pinch. Attach cells to spike (A) and attached freeze media to spike (B). Attach up to four CryoStore TM freezing bags via male luers (E). Seal off any unused tubes to reduce cell loss. Open pinch to the desired pathway, transfer cells and solutions. A rocker or oscillator is recommended for freeze media addition. D C CC35-5MT E E E E Cell Connect TM

Manifold Sets Manifold sets are tube sets with multiple terminals and adapters that minimize sample handling and streamline processing. F-8S100 F-8S100 One female luer to eight spikes with 100cm SCD tubing and pinch 12 SDv-9M141 SDv-9M141 One spike and vented drip chamber to nine male luers with 140cm SCD tubing and pinch 10 Manifold Sets

Sterile Components Sterile Components Components for your laboratory processes. SC-1 SC-1* CT Description Stock or A 4-way stopcock that regulates the flow of fluid through a tube Stock Description Stock or Cryotape. Cryogenic tape that is stable in LN vapor phase 1¼ X 8 strips Stock 50 10

Americas & Asia 7000 Burleson Rd, Bldg D Austin, TX USA 78744-3202 Tel: +1 (512) 474 7278 Tel: Toll Free (800) 233 9014 Fax: Toll Free (888) 812 8411 or +1 (512) 617 1503 E-mail: sales.us@origen.com Distributed by: www.dlongwood.com ML04.01.R00 2014 Issue Europe & Middle East OriGen Biomedical GmbH Romerstrasse 14 72393 Burladingen, Germany Tel: +49-7475-915591 Fax: +49-7475-914718 E-mail: sales.europe@origen.com