Hearing Impairment in Pre-eclampsia

Similar documents
Research Article Preeclampsia as a Risk Factor for Damage of the Cochlear Outer Hair Cells Function

Hearing Loss as a Complication of Pre-eclampsia?

Technical Report: Distortion Product Otoacoustic Emissions That Are Not Outer Hair Cell Emissions DOI: /jaaa

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

FALSE POSITIVE DP GRAMS

functional, toxicological, and pharmacological similarities between inner ear cells and cells of the kidney tubules.

HEARING IMPAIRMENT LEARNING OBJECTIVES: Divisions of the Ear. Inner Ear. The inner ear consists of: Cochlea Vestibular

A Review of the Effectiveness of Otoacoustic Emissions for Evaluating Hearing Status After Newborn Screening

Introduction. IAPA: June 04 1

TEMPORARY HEARING THRESHOLD SHIFT MEASURED BY OTOACOUSTIC EMISSIONS IN SUBJECTS EXPOSED TO SHORT-TERM IMPULSE NOISE

Emissions are low-intensity sounds that may be detected in the external ear canal by a microphone

Clinical applications of otoacoustic emissions in Industry. Prof. Dr. B. Vinck, MSc, PhD University of Ghent, Belgium

Role of Distortion Product Otoacoustic Emissions (DPOAES) In Detecting Early Hearing Impairment in Individuals With Normal Pure Tone Audiometry (PTA)

OAE Test System. Screener PLUS. Diagnostic PLUS. with 4 frequency DPOAE testing Protocols

OAE Test System. by Maico Diagnostics ERO SCAN. EroScan Pictured. OAE Hearing Screener DPOAE/TEOAE Test Systems.

Terri-Lynn Gagnon M.Cl.Sc (AUD) Candidate University of Western Ontario: School of Communication Sciences and Disorders

Advanced. NEW! Four times faster DPOAE: concurrent measurement of both ears while recording two DPs simultaneously in each ear!

Hearing Evaluation: Diagnostic Approach

ERO SCAN. OAE Test System. Screener. Diagnostic. with 4 frequency DPOAE testing Protocols

Audiology (Clinical Applications)

FINE STRUCTURE DISTORTION PRODUCT OTOACOUSTIC EMISSION DURING PREGNANCY

Cochlear and Brainstem Audiologic Findings in Normal Hearing Tinnitus Subjects in Comparison with Non-Tinnitus Control Group

A Guide to. Otoacoustic Emissions (OAEs) for Physicians.

The effect of acoustic reflex on contralateral suppression of transient-evoked otoacoustic emissions

S ensorineural hearing loss has been

Audiological Diagnosis after Newborn Screening

(OAEs) for. Physicians. Steven D. Smith, Au.D.

Clinical Study Unilateral Auditory Neuropathy Caused by Cochlear Nerve Deficiency

Utility of Standard DPOAEs in the Evaluation of the Normal-Hearing Tinnitus Patient

Journal of American Science 2017;13(12) Hearing Function in Osteoporotic Patients.

Audiology. Anita Gáborján MD, PhD.

Clinical relationship between auditory neuropathy and nervous system diseases

A Guide to. Otoacoustic Emissions (OAEs) for Otolaryngologists.

Comparison of Distortion Product Otoacoustic Emission Amplitude between Normal Hearing Male and Female Subjects

2) What is the most robust distortion product evoked with DPOAEs? A. F1 B. F2 C. 2F1-F2 D. 2F2 F1

(OAEs) for. Steven D. Smith, Au.D.

World Articles of Ear, Nose and Throat Page 1

But, what about ASSR in AN?? Is it a reliable tool to estimate the auditory thresholds in those category of patients??

PERIPHERAL AND CENTRAL AUDITORY ASSESSMENT

Ototoxicity Monitoring: The M. D. Anderson Experience. James H. Hall, Jr., M.A., CCC-A Hilary H. Arnaud, Au.D., CCC-A

by Maico Diagnostics

Hearing Sensitivity in Years Old Hypertensive Male Adults

MEASUREMENTS AND EQUIPMENT FOR AUDIOLOGICAL EVALUATIONS

Base of Audiology Anatomy and Physiology of the organ of hearing. Examinations of hearing losses with different origin.

OtoAcoustic Emissions (OAE s)

Case Report Auditory neuropathy: A case report and review of literature

Handheld OAE-Tympanometry Combination System

A Case Study of Progressive Auditory Neuropathy

Improving the diagnostic power of otoacoustic emissions. Arturo Moleti Physics Department University of Roma Tor Vergata

ORIGINAL ARTICLE. The Distribution of Risk Factors among High Risk Infants who Failed at Hearing Screening

Submitted Oct 29, 2007; Accepted: Mar 14, 2008; Published: Apr 10, 2008

Introduction to Audiology: Global Edition

Basic Audiogram Interpretation

Neuro-Audio Version 2010

Wheeler, K.S. M.Cl.Sc. (Aud) Candidate School of Communication Sciences and Disorders, U.W.O

Emissions and Hearing Thresholds After a Six-Month Deployment on an Aircraft Carrier

ORIGINAL ARTICLES DOES VINCRISTINE AFFECT COCHLEAR FUNCTION IN CHILDREN WITH ACUTE LYMPHOBLASTIC LEUKAEMIA?

Effects of flight on auditory function in pilots

Otoacoustic Emissions As A Test Of Noise-Induced Hearing Loss. Brenda L Lonsbury-Martin PhD

Etiological evaluation of hearing loss in chronic renal failure

A Case of Hysteria? By Amy Ariss and Ingrid McBride

The clinical Link. Distortion Product Otoacoustic Emission

Auditory Neuropathy/Dyssynchrony: A Retrospective Analysis of 15 Cases

photo courtesy of Oticon Glossary

Distortion product otoacoustic emissions as a health surveillance technique for hearing screening in workers in the steel manufacturing industry

Synaptopathy Research Uwe Andreas Hermann

ORIGINAL ARTICLE. Familial temperature-sensitive auditory neuropathy/auditory dyssynchrony

NOISE INDUCED HEARING LOSS AND AUDIOMETRY

Comparison of Sensorineural Hearing Loss Degree between Controlled and Uncontrolled Type 2 Diabetes Mellitus Patients

ABR PTA ASSR Multi-ASSR OAE TEOAE DPOAE SOAE VEMP ECochG MLR P300

Psychological and Audiological Profile of Tinnitus Patients

Bone Anchored Hearing Aids

More robust estimates for DPOAE level at audiometric frequencies

Advanced otoacoustic emission detection techniques and clinical diagnostics applications

Glossary For Parents. Atresia: closure of the ear canal or absence of an ear opening.

Proceedings of Meetings on Acoustics

first described by Starr 1996 as a subgroup of patients with

KANSAS GUIDELINES FOR INFANT AUDIOLOGIC ASSESSMENT

Acoustics, signals & systems for audiology. Psychoacoustics of hearing impairment

Psychoacoustic Characteristics of Tinnitus versus Temporal Resolution in Subjects with Normal Hearing Sensitivity

L eber s hereditary optic neuropathy (LHON) is one of the

UNILATERAL SUDDEN SENSORINEURAL HEARING LOSS AFTER GENERAL ANESTHESIA

Basal Cochlear Lesions Result in Increased Amplitude of Otoacoustic Emissions

Assessment of the Effects of Different Sound Pressure Levels on Distortion Product Otoacoustic Emissions (DPOAEs) in Rats

Ear Exam and Hearing Tests

Audiometric Techniques Program in Audiology and Communication Sciences Pediatric Audiology Specialization

Educational Module Tympanometry. Germany D Germering

Hearing in Noise Test in Subjects With Conductive Hearing Loss

An efficient test protocol for identification of a limited, sensitive frequency test range for early detection of ototoxicity

Assessment of Hearing Level after Resolution of Acute Otitis Media. Ali Maeed Al-shehri*

Coding Fact Sheet for Primary Care Pediatricians

Study on Hearing Status of Elderly Patients attending a Specialized ENT Hospital (SAHIC)

CASE REPORT. AUDITORY NEUROPATHY WITH BILATERAL BAT EARS A RARE CASE REPORT A. Sivakumar 1, V. Narendrakumar 2

Trajectory of the Aging Cochlea

Audiology Curriculum Foundation Course Linkages

Evaluation of ear function after cardiopulmonary bypass with otoacoustic emissions: a pilot study

ERO SCAN. Otoacoustic Emission Testing

Tympanogenic Labyrinthitis (Cochlear Deafness) due to chronic suppurative otitis media (CSOM)

Exploring the Association of Hearing Loss with Diabetes Mellitus: A Critical Review

The registration testing for audiometric device in CFDA

Transcription:

ISSN: 2250-0359 Research Article Volume 6 Issue 3: 135 2016 Hearing Impairment in Pre-eclampsia Mohammed A Gomaa 1 *, Mohhammed M Elbadery 2, Hisham M Samy 2, Rash A Abdel Moniem 1 and Hala A Ali 3 1 Departments of Otorhinolaryngology, Faculty of Medicine, Minia University, Egypt 2 Departments of Audiology, Faculty of Medicine, Minia University, Egypt 3 Department of Gynecology and Obstetrics Nursing, Faculty of Nursing, Minia University, Egypt *Corresponding author: Mohammed Abdel Motaal Gomaa, Departmentof Otorhinolaryngology, Collage of Medicine, Minia University, Minia University Hospital, E.N.T. Department Minia, Egypt, Tel: +2012-2733-9776; E-mail: magomaa67@yahoo.com Received: July 01, 2016; Accepted: July 25, 2016; Published: July 28, 2016 ABSTRACT Introduction: Pre-eclampsia is marked by increase in blood pressure and a raised level of protein in the urine and women will often also have swelling in the feet, legs, and hands. This condition usually appears during the second half of pregnancy; the pathological changes that happen during pre-eclampsia will be consequence of vasoconstriction of blood vessels, endothelial malfunction and ischemia. Hypertension and hemo-vascular disorder that accompany the disease can influence any organ including inner ear. The aim of the present study is to study the effect of pre-eclampsia on the inner ear by using Distortion product otoacoustic emission (DPOAEs). Patients and Methods: Our study is a prospective one that done at Otorhinolaryngology, Obstetric and Audiology clinics at Minia University Hospital, from March 2011 to December 2012. It composed of patient's group that suffer from pre-eclampsia with mean age 25.3 years old and control group representing healthy pregnant women with mean age 25.4 years old. The entire study sample was subjected to audiological evaluation (Distortion product otoacoustic emission, Immitancemetry, Stapedial reflex and pure tone audiometry). Systemic and Obstetric evaluation was done to both groups. Results: Immitancemetry, stapedial reflex and pure tone audiometry were normal in both groups, while Distortion product otoacoustic emission was statistically significant lower amplitudes in nearly one third of the patient's groups at all F2 frequencies except at 6250 Hz, while none of the ears of the control group had abnormal DPOAEs. Conclusion: Pre-eclampsia can influence cochlear function and be a risk factor for sensory neural hearing loss in affected women. Key words: Pre-eclampsia, Hearing, Cochlea Introduction: Preeclampsia is defined as increase in blood pressure and proteinuria after 20 weeks of pregnancy in a woman who not suffer previously from hypertension, if left untreated; preeclampsia can lead to serious and fatal complications for both the mother and her baby 1. Preeclampsia is a serious condition that puts pregnant women at risk for failure of multiple organs including inner ear, due to vascular events and systemic toxemia 2. Preeclampsia is a common disorder that is a consequence of vasospasm, endothelial dysfunction and ischaemia 3, Preeclampsia, which affects circulation with possible immunologic pathogenesis, can induce damage to the cochlea and result in sensory neural hearing loss 4. The aim of our study is

to evaluate cochlear changes by using Otoacoustic emission in pre-eclamptic women. Subjects and Methods: The study was approved by The Research Ethics Committee of the faculty of Medicine, Minia University. A written consent was signed by all women that enrolled in the study. The current study is a prospective study that done on 16 female patients, that suffer from pre-eclampsia (the study group); and 18 healthy pregnant mothers represent the control group. The mean age of study group was 25.3 years and that of control group was 25.4 years old. The study was done at Otorhinolaryngology, Obstetric and Audiology clinics at Minia University Hospital, from March 2011 to December 2013. All patients and control groups subject to: 1. Detailed medical history 2. Obstetric examination 3. Laboratory investigation in the form of (complete blood count, blood glucose, renal function tests, liver function tests and urine analysis) 4. Full Otorhinolaryngological examination 5. Medical examination including measurement of blood pressure. The patient is diagnosed as having pre-eclampsia if she passed 20 weeks gestation; blood pressure is 140/90 mmhg or higher-documented on two measures, at least six hours apart but no more than seven days apart and there is protein in urine after urine analysis. Exclusion criteria: a. Patients with chronic suppurative otitis media (unilateral or bilateral) b. Patients with previous ear surgery c. Patients with known history of hearing loss d. Patients with otosclerosis e. Patients with previous medical diseases like Diabetes, Hypertension, autoimmune diseases. Audiological evaluation: 1. Immitancemetry using Zodiac 401 middel ear analyser to measure middle ear preassure and stapedial muscle reflex at frequencies 500, 1000, 2000, and 4000 Hz. 2. Pure tone audiometry using Amplaid 309 audiometer for assessment of hearing sensitivity. Air conduction (AC) threshold was obtained for the frequency range 250-8000 Hz at single octave intervals through using TDH 49 ear phone, while bone conduction (BC) threshold was obtained for the frequency range 500-4000 Hz at single octave intervals using B71 bone vibrator. 3. Distortion product otoacoustic emission (DPOAE) to test the cochlear function. DPOAE was recorded using the Intelligent Hearing system with Smart OAE 4.5 software. Two tones were used; L1=65 db SPL and L2=55 db SPL, while f2/f1 was 1.22. Both the amplitude of response of the distortion product (DP) at 2 f1-f2 and background noise (Ns) were obtained at 9 points corresponding to f2 frequencies of 553, 783, 1105, 1560, 2211, 3125, 4416, 6250 and 8837 Hz. These measurements were used to build DP-gram by displaying the DP against the F2 frequency. The SNR was measured (SNR=DP-Ns) at each of these 9 points. DPOAE was consi dered normal and thereby reflecting normal cochlear function if the SNR was equal to or greater than 3 db SPL on at least 70% of the tested frequencies. Our data was collected and analyzed statistically by using student t-tests Results: Our results revealed statistically significant lower DPOAE amplitudes in the study groups at all F2 frequencies except at 6250 Hz, while none of the ears of the control groups had abnormal DPOAEs (Tables 1 and 2). Show Mean and SD of DPOAE amplitudes in db SPL of the right and left ear-consequently for both study and control groups; in addition to t and p values of the student t test. The results of the present study revealed that 36.4% of patients of the study group had abnormal DPOAEs (i.e., the DPOAEs was greater than 3 db SPL in less than 70% of the tested frequencies) Our results pointed out that there is no statistical difference between patient and control groups in Immitancemetry and stapedial muscle reflex, as they were normal in both groups. Our results showed also, that pure tone audiometry at examined frequencies were normal in both groups Discussion: Otoacoustic emissions especially the distortion

F2 Frequency (khz) Group Mean SD T value P value 1105 Study Group 7.89 8.51 Control Group 14.2 6.87 3.6 0.001 1560 Study Group 10.00 11.66 Control Group 23.4 4.88 5.6 0.000 2211 Study Group 17.14 5.94 Control Group 28.0 5.02 6.3 0.000 3125 Study Group 16.29 7.78 Control Group 25.9 8.0 3.6 0.001 4416 Study Group 10.00 5.10 Control Group 17.8 9.0 4.3 0.000 6250 Study Group 9.27 7.01 Control Group 9.5 3.93 0.19 0.84 Table 1: Mean and SD of DPOAE amplitudes in db SPL of the right ear for both study and control groups; in addition to the t and p values of the student t test. F2 Frequency (khz) Group Mean SD T value P value 1105 Study Group 7.75 8.55 Control Group 15.75 4.15 3.56 0.001 1560 Study Group 13.25 11.38 Control Group 20.44 5.36 5.62 0.000 2211 Study Group 15.13 9.2 Control Group 24.9 3.81 6.42 0.000 3125 Study Group 15.63 7.66 Control Group 22.9 6.98 3.5 0.001 4416 Study Group 7.65 6.78 Control Group 19.7 7.45 4.33 0.000 6250 Study Group 9.5 5.7 Control Group 8.3 4.56.18 0.81 Table 2: Shows mean and SD of DPOAE amplitudes in db SPL of the left ear for both study and control groups; in addition to the t and p values of the student t test. product type (Distortion product otoacoustic emissions; DPOAEs) is a sensitive test for cochlear function. It has excellent test retest reliability and it can detect sub-clinical cochlear abnormality before these abnormalities manifest clinically in the conventional audiogram. Therefore it has been used to monitor cochlear function in patients taking ototoxic medications as gentamycin and subject under noise exposure. Compared to the transient otoacoustic emissions (TOAEs), DPOAEs is more frequency specific and test wider frequency range than TEOAEs 5. Arterial hypertension may affect hearing by different ways. High pressure in the cochlear microcirculation may cause haemorrhage in the inner ear, which may cause progressive or sudden sensory neural hearing loss. As blood viscosity is increased due to pre-eclampsia the capillary blood flow and oxygen saturation in the cochlea are reduced which causes tissue hypoxia that can cause hearing deficits and hearing loss in hypertensive patients. Moreover, increase in arterial blood pressure may cause ionic changes in cell potentials of the hair cells of the cochlea, thus causing hearing loss 6-9. The pathogenesis of preeclampsia is complicated and not fully understood. It may be associated with multiorgan failures of the mother, coagulopathy, vasospasm, ischemia and microthrombi in peripheral circulation that my lead to maternal and foetal 4,10. Bakhshaee et al. stated that damage to the cochlear hair cells during preeclampsia was possible. Theyevaluated hearing in 37 preeclamptic patients and 38 healthy women with TEOAE and reveal significant differences between the two groups, as 13.5% of pre-eclamptic women had abnormality in TEOAE. These findings pointed out the possible effect of preeclampsia on the cochlea at least temporarily 4. Our results showed that 36.4% of the ears of pre-eclamptic women had abnormal DPOAEs

which agree with Bakhshaee et al. and as we use of DPOAEs which is more sensitive than TEOAE, explain the higher results that we have. Altunta et al. pointed out that, there was no significant difference between hypertensive and healthy pregnant women in terms of hearing assessment, but damage to the cochlear hair cells consequent to hypertension during pregnancy is possible. The results of his study suggested that ischaemia of the inner ear that caused by microthrombus and vasospasm in hypertensive patients during pregnancy does not result in hearing impairment in the postpartum period 6. Our results disagree with Altunta et al. as there is hearing impairment detected by DPOAEs in 36.4% of preeclmptic women. Ozdemir et al. found statistically significant differences between per-eclamptic and healthy women in pure-tone audiometric results. However, these results were irrelevant clinically as all puretone thresholds were lower than 20 db (normal hearing abilities). The differences between brainstem auditory-evoked potentials were not statistically significant 11. Our results disagree with Ozdmir et al. as there is no statistical difference between both groups in pure tone audiometery and our data showed significant difference between patient's group and control group regarding DPOAEs. Baylan et al. OAE-right, and OAE-left differed significantly between pre-eclamptic patient and control groups also bone conduction at 500 Hz significantly differ between both groups in pure tone audiometry 12. Our results agree with Baylan in OAE results but differ in pure tone audiometery as our results pointed out that no statistical difference between both groups regarding pure tone audiometery. Conclusion: Our results pointed out that pre-eclampsia can influence the cochlea and in turn it may be a risk factor for sensory neural hearing loss in pregnant women, this may be temporarily. We recommend doing this study on wide scale of patients and following them for a while in postpartum.

References 1. Myo clinic (2010) Pre-eclampsia 2. Bakhshaee M, Boskabadi H, Hassanzadeh M (2008) Hearing impairment in the neonate of preeclamptic women. Otolaryngol Head Neck Surg 139: 846-849. 3. Roberts JM, Pearson G, Cutler J (2003) Summary of the NHLBI working group on research on hypertension during pregnancy. Hypertension 41: 437-445. 4. Bakhshaee M, Hassanzadeh M, Nourizadeh N, Karimi E, Moghiman T, et al. (2008) Hearing impairment in pregnancy toxemia. Otolaryngol Head Neck Surg 139: 298-300. 5. Vinck BM, Van Cauwenberge PB, Leroy L, Corthals (1999) Sensitivity of transient evoked and disortion product otoacoustic emissions to direct effects of noise on the human cochlear. Audiol 38: 44-52 6. Altuntaş EE, Yenicesu AGI, Mutlu AE, Muderris S, Çetin M, et al. (2012) An evaluation of the effects of hypertension during pregnancy on postpartum hearing as measured by transient-evoked otoacoustic emissions. Acta Otorhinolaryngol Ital 32: 31-36. 7. Moraes L, Almeida E, Matsuo T (2006) Hypertension as a factor associated with hearing loss. Braz J Otorhinolaryngol 72: 533-540. 8. Nagahara K, Fisch U, Yagi N (1983) Perilymph oxygenation in sudden and progressive sensorineural hearing loss. Acta Otolaryngol 96: 57-68. 9. Maddox PT, Saunders J, Chandrasekhar SS (2009) sudden hearing loss from PDE-5 inhibitors: a possible cellular stress etiology. Laryngoscope 119: 1586-1589. 10. Yinon Y, Kingdom JC, Odutayo A (2010) vascular dysfunction in women with a history of preeclampsia and intrauterine growth restriction: insights into future vascular risk. Circulation 122: 1846-1853. 11. Ozdemir I, Yilmaz S, Albayrak M, Yıldızbas S, Guven DG, et al. (2011) Hearing evaluation in preeclamptic patients.gynecol Obstet Invest 72: 1-4. 12. Baylan MY, Kuyumcuoglu U, Kale A, Celik Y, Topcu I (2010) Is preeclampsia a new risk factor for cochlear damage and hearing loss? Otol Neurotol 31: 1180-1183.