Prepublication Requirements

Similar documents
AAPM Annual Meeting. ACR Accreditation Update in CT

Implementation of the 2012 ACR CT QC Manual in a Community Hospital Setting BRUCE E. HASSELQUIST, PH.D., DABR, DABSNM ASPIRUS WAUSAU HOSPITAL

CT Quality Control Manual FAQs

Utilize radiation safety principles to reduce the amount of radiation used to achieve desired clinical result.

Dental ConeBeam Computed Tomography (CBCT) X-ray Systems

Radiation Dose Specification

REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22

BICOE Breast Imaging Center of Excellence. What is it? - Requirements. National Mammography Database. What do you get? ACR Accreditation in:

Bureau of Laboratory Quality Standards

BICOE Stereotactic Breast Biopsy and Breast Ultrasound Accreditation. Introduction. Educational Objectives

NCRP PAC 4: Radiation Protection in Medicine. Overview. NCRP and PAC 4. Donald L. Miller, MD FSIR FACR Center for Devices and Radiological Health FDA

created by high-voltage devices Examples include medical and dental x-rays, light, microwaves and nuclear energy

BICOE Stereotactic Breast Biopsy and Breast Ultrasound Accreditation. Introduction. Educational Objectives

Computed tomography Acceptance testing and dose measurements

RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY. L19: Optimization of Protection in Mammography

Mapping the ASRT Objectives for Radiation Protection (47 Objectives) and Radiation Biology (21 Objectives) to this Text

CT Radiation Risks and Dose Reduction

ACR Accreditation Toolkit for Validation Site Surveys

ACR MRI Accreditation: Medical Physicist Role in the Application Process

The IAC Standards and Guidelines for Dental CT Accreditation

Bone Densitometry Equipment Operator

icat Precise Policy and Procedure Manual

Toshiba Aquillion 64 CT Scanner. Phantom Center Periphery Center Periphery Center Periphery

organizations including the International Commission on Radiation Protection exposure dose management system to all the studies and

Revised: 8/05; 9/08; 9/09; 8/11; 8/12; 1/13 Reviewed: 3/10

Compliance with TJC Guidelines on CT Clinical Practice

NONE. Disclosures. Accreditation Update

ACR MRI Accreditation Program. ACR MRI Accreditation Program Update. Educational Objectives. ACR accreditation. History. New Modular Program

354 Korean J Radiol 9(4), August 2008

Investigation of the clinical performance of a novel solid-state diagnostic dosimeter

Testing of the Implementation of the Code of Practice on Dosimetry in X-ray Diagnostic Radiology Hungarian Contribution

Kish chakrabarti, Ph.D. Senior Physicist CDRH/FDA

Establishing the quality management baseline in the use of computed tomography machines in Kenya

X-Ray & CT Physics / Clinical CT

Agenda: Dental Cone Beam Imaging

Dental Extraoral X-ray Systems

Dental Intraoral X-ray Systems

Accounting for Imaging Dose

Appendix I. List of stakeholders consulted with on the Patient Radiation Protection Manual and members of the Medical Exposure Radiation Unit

Prepublication Requirements

SOMATOM Drive System Owner Manual Dosimetry and imaging performance report

The New Jersey Radiographic Quality Assurance Program at 5 Years

STANDARD OF PRACTICE. Dental CT Scanners CONTENTS. April 2011

Disclosure. Outline. Machine Overview. I have received honoraria from Accuray in the past. I have had travel expenses paid by Accuray in the past.

Managing Cone Beam CT Dose in Paediatric Dental Imaging

PHYS 383: Applications of physics in medicine (offered at the University of Waterloo from Jan 2015)

INTER-AMERICAN UNIVERSITY OF PUERTO RICO

Establishment of local diagnostic reference levels for quality control in intraoral radiography

Overview. ACR Accreditation Update in Mammography. New ACR Activities. Requirements Today. What s New For Tomorrow. ACR: Recognized by FDA and CMS

ASRT Position Statements

SBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session

Radiation Safety Characteristics of the NOMAD Portable X-ray System

Preparing for Medical Physics Components of the ABR Core Examination

A. DeWerd. Michael Kissick. Larry. Editors. The Phantoms of Medical. and Health Physics. Devices for Research and Development.

Scientific Affairs. Scientific Affairs

Current status of diagnostic imaging in dental university hospitals in Japan

Mammography Quality Control: A Refresher

Doses from pediatric CT examinations in Norway Are pediatric scan protocols developed and in daily use?

IAEA TECDOC 1517 Quality Control in Mammography Software

Standards for Radiation Oncology

Adopting DAP as a dose metric in CT

Quality assurance in external radiotherapy

Catalog Addendum

Managing the imaging dose during Image-guided Radiotherapy. Martin J Murphy PhD Department of Radiation Oncology Virginia Commonwealth University

Medical Fluoroscopic Exposures and Incidents

Joint ICTP/IAEA Advanced School on Dosimetry in Diagnostic Radiology and its Clinical Implementation May 2009

Limited X-ray Machine Operator (LXMO) Curriculum Analysis

Document Control Report

Sasa Mutic a) Department of Radiation Oncology, Washington University School of Medicine, St. Louis, Missouri 63110

3/5/2015. Don t Electrocute Me!: Common Misconceptions in Imaging and Radiation Safety (and What to Do About Them)

MR QA/QC for MRgRT. Rick Layman, PhD, DABR Department of Radiology July 13, 2015

Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

NJ CBCT Regulation FAQ & Assistance

CURRICULUM OUTLINE FOR TRANSITIONING FROM 2-D RT TO 3-D CRT AND IMRT

8/18/2011. Acknowledgements. Managing Pediatric CT Patient Doses INTRODUCTION

Managing Radiation Risk in Pediatric CT Imaging

National Cancer Peer Review Programme. Radiotherapy Service Evidence Guide

Over the past 18 months several articles have appeared in the New York Times and other

X-RAY REGULATORY GUIDE

Table of Contents. Introduction 3. Background 4

The IAC Standards and Guidelines for Cardiac Electrophysiology Accreditation

Why is CT Dose of Interest?

Introduction and Background

Overview. ACR Update on FFDM Accreditation. New ACR Activities. QC Today. QC Tomorrow. ACR Breast Imaging Centers of Excellence BICOE

45 Hr PET Registry Review Course

Bone Densitometry. Total 30 Maximum CE 14. DXA Scanning (10) 7

Low Dose CT Lung Screening: What is Technically Required?

Medical Diagnostic Imaging

Overview of TG225 - Medical Physics Practice Guideline #1

ABSTRACT I. INTRODUCTION

Radiation Safety & Determining Need for Radiographs

Dental Radiography Core Subject. Digital Radiography

Patient dose assessment of CT perfusion scanning at the RSCH

Update on MQSA and Mammography Accreditation

19 CP Add teaching file export related codes

Radiation Safety in the Catheterization Lab

Further there has been shift from equipment focus to patient focus. During the last 15 years QC testing of equipment and dosimetry in phantoms

EXAMINATION CONTENT SPECIFICATIONS ARRT BOARD APPROVED: JANUARY 2017 IMPLEMENTATION DATE: JULY 1, 2017

User Guide for Dental and Maxillofacial Cone Beam Computed Tomography (CBCT)

Managing the imaging dose during image-guided radiation therapy

Transcription:

Issued Prepublication Requirements Standards Revisions for Organizations Providing Fluoroscopy Services The Joint Commission has approved the following revisions for prepublication. While revised requirements are published in the semiannual updates to the print manuals (as well as in the online E-dition ), accredited organizations and paid subscribers can also view them in the monthly periodical The Joint Commission Perspectives. To begin your subscription, call 800-746-6578 or visit http://www.jcrinc.com. Please note: Where applicable, this report shows current standards and EPs first, with deleted language struckthrough. Then, the revised requirement follows in bold text, with new language underlined. APPLICABLE TO AMBULATORY HEALTH CARE Effective January 1, 2019 Standard EC.02.04.03 The organization inspects, tests, and maintains medical equipment. Elements of Performance for EC.02.04.03 21. For diagnostic computed tomography (CT) services: At least annually, a diagnostic medical physicist conducts a performance evaluation of all CT imaging equipment. The evaluation results, along with recommendations for correcting any problems identified, are documented. The evaluation includes the use of phantoms to assess the following imaging metrics: - Image uniformity - Slice thickness accuracy - Slice position accuracy (when prescribed from a scout image) - Alignment light accuracy - Table travel accuracy - Radiation beam width - Low-contrast resolution - Geometric or distance accuracy - CT number accuracy and uniformity - Artifact evaluation Note 1: This element of performance does not apply to dental cone beam CT radiographic Note 2: Medical physicists are accountable for these activities. They may be assisted with the testing and evaluation of equipment performance by individuals who have the required training and skills, as determined by the physicist. (For more information, refer to HR.01.02.01, EP 1; HR.01.02.05, EP 20; HR.01.02.07, EPs 1 and 2; HR.01.06.01, EP 1; LD.03.06.01, EP 4.) Copyright 2018 The Joint Commission 1

21. 34. For diagnostic computed tomography (CT) services: At least annually, a diagnostic medical physicist conducts a performance evaluation of all CT imaging equipment. The evaluation results, along with recommendations for correcting any problems identified, are documented. The evaluation includes the use of phantoms to assess the following imaging metrics: - Image uniformity - Scout prescription accuracy - Alignment light accuracy - Table travel accuracy - Radiation beam width - Low-contrast detectability - Geometric or distance accuracy - CT number accuracy and uniformity - Artifact evaluation Note 1: This element of performance does not apply to dental cone beam CT Note 2: Medical physicists are accountable for these activities. They may be assisted with the testing and evaluation of equipment performance by individuals who have the required training and skills, as determined by the physicist. (For more information, refer to HR.01.02.01, EP 1; HR.01.02.05, EP 20; HR.01.02.07, EPs 1 and 2; HR.01.06.01, EP 1; LD.03.06.01, EP 4.) For organizations that provide fluoroscopic services: At least annually, a diagnostic medical physicist conducts a performance evaluation of fluoroscopic imaging equipment. The evaluation results, along with recommendations for correcting any problems identified, are documented. The evaluation includes an assessment of the following: - Beam alignment and collimation - Tube potential/kilovolt peak (kv/kvp) accuracy - Beam filtration (half-value layer) - Low-contrast detectability - Maximum exposure rate in all imaging modes - Displayed air-kerma rate and cumulative-air kerma accuracy (when applicable) Note 1: Medical physicists conducting performance evaluations may be assisted with the testing and evaluation of equipment performance by individuals who have the required training and skills, as determined by the physicist. Note 2: This element of performance does not apply to fluoroscopy equipment used for Copyright 2018 The Joint Commission 2

Standard HR.01.05.03 Staff participate in ongoing education and training. Elements of Performance for HR.01.05.03 14. 14. 15. The organization verifies and documents that technologists who perform diagnostic computed tomography (CT) examinations participate in ongoing education that includes annual training on the following: - Radiation dose optimization techniques and tools for pediatric and adult patients addressed in the Image Gently and Image Wisely campaigns - Safe procedures for operation of the types of CT equipment they will use Note 1: Information on the Image Gently and Image Wisely initiatives can be found online at http://www.imagegently.org and http://www.imagewisely.org, respectively. Note 2: This element of performance does not apply to CT systems used for therapeutic radiation treatment planning or delivery, or for calculating attenuation coefficients for nuclear medicine studies. Note 3: This element of performance does not apply to dental cone beam CT radiographic The organization verifies and documents that individuals who perform diagnostic computed tomography (CT) examinations participate in ongoing education that includes annual training on the following: - Radiation dose optimization techniques and tools for pediatric and adult patients addressed in the Image Gently and Image Wisely campaigns - Safe procedures for operation of the types of CT equipment they will use Note 1: Information on the Image Gently and Image Wisely initiatives can be found online at http://www.imagegently.org and http://www.imagewisely.org, respectively. Note 2: This element of performance does not apply to CT systems used for therapeutic radiation treatment planning or delivery, or for calculating attenuation coefficients for nuclear medicine studies. Note 3: This element of performance does not apply to dental cone beam CT The organization verifies and documents that individuals (including physicians, nonphysicians, and ancillary personnel) who use fluoroscopic equipment participate in ongoing education that includes annual training on the following: - Radiation dose optimization techniques and tools for pediatric and adult patients addressed in the Image Gently campaign - Safe procedures for operation of the types of fluoroscopy equipment they will use Note 1: Information on the Image Gently initiative can be found online at http://www.imagegently.org. Note 2: This element of performance does not apply to fluoroscopy equipment used for Copyright 2018 The Joint Commission 3

Standard LD.04.01.05 The organization effectively manages its programs, services, or sites. Elements of Performance for LD.04.01.05 The organization designates an individual to serve as the radiation safety officer who is responsible for making certain that radiologic services are provided in accordance with law, regulation, and organizational policy. This individual has the necessary authority and leadership support to do the following: - Monitor and verify compliance with established radiation safety practices (including oversight of dosimetry monitoring) - Provide recommendations for improved radiation safety - Intervene as needed to stop unsafe practices - Implement corrective action Standard PC.01.02.15 The organization provides for diagnostic testing. Elements of Performance for PC.01.02.15 13. For organizations that provide fluoroscopic services: The, cumulative-air kerma or kerma-area product are documented in a retrievable format. For fluoroscopy equipment that cannot display or provide cumulative-air kerma or kerma-area product, fluoroscopy time and number of images acquired are documented in a retrievable format, such as a picture archiving and communication system. Note: This element of performance does not apply to fluoroscopy equipment used for Standard PC.01.03.01 The organization plans the patient s care. Elements of Performance for PC.01.03.01 The organization establishes or adopts diagnostic computed tomography (CT) imaging protocols based on current standards of practice, which address key criteria including clinical indication, contrast administration, age (to indicate whether the patient is pediatric or an adult), patient size and body habitus, and the expected radiation dose index range. Note: This element of performance does not apply to dental cone beam CT radiographic Copyright 2018 The Joint Commission 4

The organization establishes or adopts diagnostic computed tomography (CT) imaging protocols based on current standards of practice, which address key criteria including the following: - Clinical indication - Contrast administration - Age (to indicate whether the patient is pediatric or an adult) - Patient size and body habitus - Expected radiation dose index range Note: This element of performance does not apply to dental cone beam CT Standard PC.02.01.01 The organization provides care, treatment, or services for each patient. Elements of Performance for PC.02.01.01 30. For organizations that provide fluoroscopic services: The organization identifies radiation exposure and skin dose threshold levels, that if exceeded, trigger further review and/or patient evaluation to assess for adverse radiation effects. Note 1: Information on radiation exposure thresholds can be found in the National Council on Radiation Protection (NCRP) s report number 168 and on the Food and Drug Administration s (FDA) Center for Devices for Radiological Health (CDRH) website. Note 2: Radiation exposure thresholds may be established based on metrics such as reference-air kerma, cumulative-air kerma, kerma-area product, or fluoroscopy time. (See also PI.02.01.01, EP 20) Standard PI.02.01.01 The organization compiles and analyzes data. Elements of Performance for PI.02.01.01 20. For organizations that provide fluoroscopic services: The organization reviews and analyzes instances where the radiation exposure and skin dose threshold levels identified by the organization are exceeded. Note: Radiation exposure thresholds may be established based on metrics such as reference-air kerma, cumulative-air kerma, kerma-area product, or fluoroscopy time. (See also PC.02.01.01, EP 30) Copyright 2018 The Joint Commission 5