A COMPARATIVE EVALUATION OF HBA1C MEASUREMENT IN DIFFERENT ANTICOAGULANT VIALS AND ITS STABILITY ON STORAGE

Similar documents
A Simplified Indian Diabetes Risk Score for Screening for Undiagnosed Diabetic Subjects

Study of correlation of severity of diabetic retinopathy with levels of haemogloelbin A1c in patients with type II Diabetes Mellitus

Prevalence of Diabetes and Pre-Diabetes in Healthy Obese Employees

Screening of Type II Diabetes Mellitus on the Basis of IDRS Among Urban Population of Bhopal, Madhya Pradesh

Analysis of Hemoglobin A1c from Dried Blood Spot Samples with the Tina-quant II Immunoturbidimetric Method

Hemoglobin A1c: Comparison of Pointe Scientific s 2-Part Direct Hemoglobin A1c with the Bio-Rad Variant II and the Tosoh G8

Journal of Diabetes and Metabolic Disorders; 2011; Vol 10, pp 1-6. Keywords: Glycated hemoglobin, Paper filter, Diabetes, Dried blood spot.

External Quality Assessment of HbA 1c for Point of Care Testing

The influence of sample freezing at 80 C for 2 12 weeks on glycated haemoglobin (HbA 1c

REVIEW Global standardisation of HbA 1c

Prevalence of Diabetes Mellitus among Non-Bahraini Workers Registered in Primary Health Care in Bahrain

JMSCR Vol 06 Issue 10 Page October 2018

Mean Plasma Glucose Level - A Surrogate Marker to Glycated Haemoglobin Level For Assessment of Glycaemic Control

Correlation between eag Values Calculated from HbA1C Values and Fasting Plasma Glucose Levels for Diagnosis and Prognosis of Diabetes

Prevalence of pre-diabetes among the general population in a tertiary care hospital in north India

Effect of bitter gourd clinical trial in prediabetics: blind, randomised, cross over trial in India

A validation study of after reconstitution stability of diabetes: level 1 and diabetes level 2 controls

International Journal of Health Sciences and Research ISSN:

Epidemiology of Diabetes Mellitus in Asia

International Journal of Health Sciences and Research ISSN:

HbA1c enzymatic assay evaluation at AN academic

Prevalence of Undiagnosed Diabetes Mellitus amongst Hypertensive Patients Attending an Outpatient Clinic in Harare, Zimbabwe

Diabetes Management and Considerations for the Indian Culture

Tosoh Automated Glycohemoglobin Analyzer HLC-723GX

Glycemic Control in Type 2 Diabetes Mellitus Patients

Risk Monitor How-to guide

International Journal of Health Sciences and Research ISSN:

D. Hilton. Keywords Epidemiological methods, aging, prevalence.

History of the Vacutainer Tube. Coagulant Blood Tests

The DIABETES CHALLENGE IN PAKISTAN FIFTH NATIONAL ACTION PLAN

This PDF is available for free download from a site hosted by Medknow Publications

Accuracy of Filter Paper Method for Measuring Glycated Hemoglobin

Profile of diabetes mellitus in elderly of Chandigarh, India. S Puri, M Kalia, H Swami, A Singh, Abhimanyu, C Mangat, A Kaur, S Kaur

Why Do We Treat Obesity? Epidemiology

EFFECTIVENESS OF THE SHG IN IMPROVING THE ECONOMIC CONDITION OF WOMEN ENTREPRENEURS IN KANPUR

A study of micro vascular complications and associated risk factors in newly diagnosed patients of type 2 diabetes mellitus

Assessment of cardiovascular risk among diabetic patients in an urban area of Kancheepuram district, India: a cross sectional study

ORIGINAL INVESTIGATION. Short-term Variability in Measures of Glycemia and Implications for the Classification of Diabetes

Relationship Between Glycosylated Hemoglobin and Risk of Microalbuminuria in Patients with Type 2 Diabetes Mellitus

USE OF MACHINE LEARNING TO PREDICT THE ONSET OF DIABETES

Diabetes Care 34: , 2011

assay Introduction Conclusions: The D-100 TM system proved to be a robust and reliable method for HbA 1c

Improving the Accuracy of Hemoglobin A 1c. : Your Help Is Needed

TUEC Guidelines Medical Information to Support the Decisions of TUE Committees Diabetes Mellitus DIABETES MELLITUS

DiabetesVoice June 2013 Volume 58 Issue 2

Case Study: Type 2 Diabetes Management Care Pathway

HBA1C AS A MARKER FOR HIGH RISK DIABETIC SURGICAL PATIENT

Abstract. Introduction. Original paper. Comparison of screening for diabetic retinopathy by non-specialists and specialists

Analysis of drug used for the treatment of complications of diabetes in a teaching hospital

UTILITY OF GLYCATED HAEMOGLOBIN IN GESTATIONAL DIABETES MELLITUS: PRESENT AND FUTURE

Association of Thyroid Hormone Levels Among Type 2 Diabetic Patients Attending a Tertiary Care Hospital

HYPERTENSION AND DIABETES IN INDIA: A REVIEW

Effect of eating frequency on prediabetes status: a self-controlled preventive trial

The Diabetes Epidemic in Korea

HbA1c (Human) ELISA Kit

ORIGINAL ARTICLE. Use of Freestyle Libre Pro TM Flash Glucose Monitoring System in Different Clinical Situations at a Diabetes Centre

Detection and quantitation of hemoglobin (Hb) fractions

Evaluation of haemoglobin A1c measurement by an enzymatic method using an automated analyser that has an on-board haemolysis system

HbA1c AS AN INDEX OF GLYCEMIC STATUS IN OBESE TYPE 2 DIABETICS

Maintaining Quality in Laboratory Medicine. Glycated Haemoglobin Scheme Guide

Keywords: glycosylated haemoglobin, plasma glucose, correlation.

Journal of Advanced Scientific Research

Review Article. Intensive glycaemic control in type 2 diabetes mellitus: Does it improve cardiovascular outcomes?

Rapid globalization and industrialization occurring

Research Article Hb A1c Separation by High Performance Liquid Chromatography in Hemoglobinopathies

EFFECT OF JAMUN SEED POWDER SUPPLEMENTATION ON THE BODY MASS INDEX AND FASTING PLASMA GLUCOSE LEVELS IN WOMEN WITH TYPE 2 DIABETES MELLITUS

College of American Pathologists (CAP) GH2 Survey Data: (updated 12/09) 2009 GH2-B (fresh pooled samples) * = NGSP certified at the time of the survey

Awareness and Prevalence of Diabetes Mellitus Among Housewives in Baneshwar of Nepal

New Guidelines for the Diagnosis of Diabetes Mellitus

A review of socio-economic factors affecting for diabetes

CHAPTER 3 DIABETES MELLITUS, OBESITY, HYPERTENSION AND DYSLIPIDEMIA IN ADULT CENTRAL KERALA POPULATION

Public-Private Partnerships: Limelight on Diabetes. Renuka Gadde VP, Global Health October 18, 2012

Key words: Type 2 diabetes mellitus; Resveratrol; Glycosylated hemoglobin; Glimepiride

Conceptual Model of Diabetes Self-Management for Middle-Aged Population of Rural Area of Pakistan

Objective The aim of this systematic review was to assess the prevalence of Gestational Diabetes mellitus in Sub-Saharan Africa.

PACIFIC JOURNAL OF MEDICAL SCIENCES ISSN:

Volume 5 Issue 8, August

ISSN X (Print) Original Research Article

Sandra Božičević dipl. ing. med. biochem, Marijana Vučić Lovrenčić, PhD Vuk Vrhovac University Clinic, Zagreb, Croatia

Mission Hb accurately detects both

Early Onset of Type 2 Diabetes in Pune

Diabetes is a condition with a huge health impact in Asia. More than half of all

An Epidemiological Study of Hypertension and Its Risk Factors in Rural Population of Bangalore Rural District

Saranya N., Suganthi M.*, Shanthi Dhinakaran, Navina N.

Prevalence of Diabetes and Associated Risk Factors among Selected Type 2 Diabetes

Initiating Insulin in Primary Care for Type 2 Diabetes Mellitus. Dr Manish Khanolkar, Diabetologist, Auckland Diabetes Centre

Evaluation Report. Eurolyser HbA1c Test Kit on Smart and Cube Analyser

Study of demographic features of abdominal tuberculosis in Urban population in Pune

International Journal of Diabetes & Metabolic Disorders

ABSTRACT. uncontrolled on basal insulin? OADs;

Quality Specifications for POCT

Pre-diabetes. Dr Neel Basudev. GPSI Lambeth DICT, Diabetes Lead Lambeth CCG

Primary Prevention of T2DM. KW Chan Endocrine & Diabetes Team Department of M&G, PMH 22 March 2009

Quality of life among type 2 diabetes patients in Udupi taluk: a cross-sectional study

Auto HbA1C ANALYZER HbA1LC HPLC 3660

Stapleton, Mary; Daly, Niamh; O'Kelly, Ruth; Turner, Michael.

Effect of Supplementation of Tulsi Leaves or Curry Leaves or Combination of both Type 2 Diabetes

THE EFFECT OF VITAMIN-C THERAPY ON HYPERGLYCEMIA, HYPERLIPIDEMIA AND NON HIGH DENSITY LIPOPROTEIN LEVEL IN TYPE 2 DIABETES

The clinical value of HbA1c in combination with FPG in the early screening of the elderly with type 2 diabetes

About the Highmark Foundation

Transcription:

IJCRR Vol 05 issue 11 Section: Healthcare Category: Research Received on: 04/04/13 Revised on: 25/04/13 Accepted on: 18/05/13 A COMPARATIVE EVALUATION OF HBA1C MEASUREMENT IN DIFFERENT ANTICOAGULANT VIALS AND ITS STABILITY ON STORAGE Devajit Sarmah, Booloo Sharma Department of Biochemistry, R.D. Gardi Medical College, Ujjain, Madhya Pradesh, India E-mail of Corresponding Author: dr.devajit@gmail.com ABSTRACT Introduction: India has an overwhelming diabetic population and the importance of HbA1c testing is felt. However the need of an additional EDTA sample and due to lack of standardised laboratories in most part of India, samples are stored and transported for testing. The study aims to check the variation in HbA1c measurement in K 3 EDTA, Na-citrate, lithium-heparin and Na-fluoride/Na 2 EDTA anticoagulant vials and check for its stability when sample are stored at 2 8 C for 7 days. Methods and materials: HbA1c was measured by cation exchange HPLC based BioRad D - 10 analyser after collection of sample in K 3 EDTA, Na-citrate, lithium-heparin and Na-fluoride/Na 2 EDTA from 25 diabetic and 25 non - diabetic subjects on day 1 and on day 3, day 5 and day 7 of sample collection, after storage at 2 8 C. Result: There were no variation in the measured value of HbA1c in these anticoagulant vials (CV = 0.0 0.8%). There were no significant differences in the mean values of the HbA1c measured on day 1 and day 7 (8.2 ± 1.16 vs. 8.2 ± 1.18, P = 0.962 in diabetic and 5.3 ± 0.25 vs. 5.3 ± 0.24, P = 0.955 in non - diabetic). There were significant correlations between the HbA1c values measured on day 1 and after 7 days storage (r = 0.991 in diabetic and r = 0.957 in non diabetic). Conclusion: HbA1c values in fresh and stored whole blood sample does not change when analysed in K 3 EDTA, Na-citrate, lithium-heparin and Na-fluoride/Na 2 EDTA anticoagulant vials. Keywords: HbA1c, K 3 EDTA, Na-citrate, lithium-heparin and Na-fluoride/Na 2 EDTA, prolonged storage. INTRODUCTION Worldwide the prevalence of type-2 diabetes mellitus (T2DM) has been rising, and about 90 % of the diabetic populations are of T2DM. Of 371 million diabetic people worldwide, 63 millions are Indian, i.e. every sixth diabetic is an Indian, as reported by the International Diabetic Federation (IDF) 2012 report (1). The dramatic economic changes have had a great impact on urbanization and lifestyle of the Indians, which together with genetic predisposition contributed to the rise in diabetes in India (2). Also the presentation of T2DM occurs a decade earlier in Indians when compared to European population (3). Traditionally, for diagnosis of diabetes physicians rely on fasting plasma glucose (FPG) and oral glucose tolerance test (OGTT). Glycated haemoglobin (HbA1c) was done only in a few numbers of cases and it was used only for monitoring the effect of treatment. HbA1c is always considered as a stable indicator of glycaemia for the preceding three months (4). Its potential utility in diabetic care was first reported in 1985 World Health Organisation report (5), and by 2010 all the major expert committee and association across the globe including the American Diabetes Association (ADA) has recommended HbA1c for the diagnosis of Type 2 Page 80

DM, besides its role in prognosis (6). So, the importance of HbA1c estimation in diabetes has increased manifold in recent years. Most of the commercial kits for HbA1c estimation requires sample to be collected in EDTA anticoagulant. This requires additional sample collection for the patient. So, we estimated HbA1c in blood sample collected in K 3 EDTA, Na-citrate, lithium-heparin and Nafluoride/Na 2 EDTA vials separately and then we checked for any variation in HbA1c values. Also most laboratory uses fresh sample for estimation of HbA1c. As standardized methods for HbA1c estimation like high performance/pressure liquid chromatography (HPLC) etc. are not available in all the laboratories in India, so samples are to be stored and transported to a standardised laboratory for estimation. Thus, the sample requires storage until it is being analysed. It is said that HbA1c has high pre-analytical stability and is stable for 1 week when stored at 4 C and for 1 year when stored at -70 C (7, 8). So, to verify the stability of HbA1c in the above vials when stored at 2-4 C, HbA1c was estimated for 7 days in all the different anticoagulant vials, in context to Indian settings. MATERIAL AND METHODS The study was conducted from June 2012 to October 2012 in the Central Clinical Laboratory of the R D Gardi Medical College in Ujjain, India. A total of 25 adult Type 2 diabetic cases (diagnosed by ADA criteria or known cases) of either sex in the age group of 25 to 65 years, and 25 adult healthy non - diabetic patients in the same age group of either sex were considered for the present study. Only those subject who were not having any disease other than diabetes that may affect the HbA1c values were selected for the study. They were excluded based on necessary patient history and investigations. Clearance from the ethical committee and consent from the study subjects were obtained. K 3 EDTA, Na-citrate, lithium-heparin and Nafluoride/Na 2 EDTA vacutainer vials manufactured by Becton, Dickinson (BD) India, were used. The creation of the two groups is simply to ascertain the purpose of the study in samples with a normal and a higher HbA1c values separately. 2ml of venous sample were drawn in all the four different vacutainers from each of the diabetic patients and healthy individuals, using standard venipuncture techniques. HbA1c was estimated after 2 hours of blood collection by cation exchange HPLC based BioRad D - 10 dual programme analyzer, manufactured by BioRad, USA. Just after estimation, vials were stored at 2-8 o C and then HbA1c measured every alternate day till 7 th day in all the vials i.e. on 1 st (day of sample collection), 3 rd, 5 th and 7 th day. The results were expressed as mean ± SD. The difference between the initial HbA1c values and the values after storage were determined using paired student s t-tests while the correlation between the initial HbA1c values in the different anticoagulant vial and the values after storage were determined by Pearson correlation technique. A P-value < 0.05 was considered statistically significant on two-tailed testing for all analysis. RESULTS The present study shows no significant change in the measured value of HbA1c when it was measured using vacutainers containing different anticoagulant mentioned above in both the groups, i.e., the group with a normal HbA1c (non-diabetic) and the group with a higher HbA1c values(diabetic). The measured range of HbA1c value in diabetic group was from 7.1% to 11.3%. The mean HbA1c being 8.2% in this group. The range of HbA1c value in non-diabetic group was from 4.5% to 5.6%. The mean HbA1c being 5.3% in this group. The first day (day 1) estimated HbA1c value in the four different anticoagulant vials for the 25 Page 81

diabetic samples were expressed as mean ± SD. The mean ranges from 7.1 11.3% and the SD ranges from ± (0.00 0.06), hence the variation was insignificant. The coefficient of variation for the 25 diabetic samples measured on day 1 among four different anticoagulant vials ranges from 0.0 to 0.8%. In the non-diabetic group the measured HbA1c value for day 1 when expressed as mean ± SD, the mean ranges from 4.5 5.6% and SD ranges from ± (0.00 0.06). Also the coefficient of variation for the 25 non - diabetic samples measured on day 1 among four different anticoagulant vials ranges from 0.0 to 0.8%. Similar results were found for the HbA1c values measured in the four different anticoagulant vials among both the diabetic and non - diabetic group on day 3, day 5 and day 7. The study therefore proves that there was no variation in measurement of HbA1c when it was measured in K 3 EDTA, Na-citrate, lithium-heparin and Nafluoride/Na 2 EDTA vacutainer vials. Figure I and II shows the mean HbA1c measured in different anticoagulant vials among the 25 diabetic samples and non-diabetic samples respectively on day 1, day 3, day 5 and day 7 of testing. The figures depicts that the mean HbA1c varies from 8.2 8.22% and 5.3 5.32% for diabetic and non-diabetic samples respectively. When the HbA1c was measured in all the four anticoagulant vials on day 3, day 5 and day 7, the mean HbA1c value did not vary in both the diabetic and non - diabetic group. There was no significant differences in the mean values of the HbA1c measurement on day 1 and the values obtained after storage for 7 days (8.2 ± 1.16 vs. 8.2 ± 1.18 in diabetic and 5.3 ± 0.25 vs. 5.3 ± 0.24 in non - diabetic), and the P value being 0.962 and 0.955 for the diabetic group and non - diabetic group, respectively. Figure III and IV shows the correlation between the HbA1c measurement on day 1 and day 7 in the diabetic and non - diabetic group, respectively. There were significant correlations between the HbA1c values measured on day 1 and day 7 after storage in both the diabetic group (r=0.991) and the non - diabetic group (r=0.957). Also the inter assay coefficient of variation for the day 1 and day 7 sample in the diabetic and the non - diabetic group was 14.0 % and 4.6 %, respectively. The study therefore proves that there was no variation in measured values of HbA1c after storage at 2 8 o C for 7 days irrespective of the collection of sample in K 3 EDTA, Na-citrate, lithium-heparin or Na-fluoride/Na 2 EDTA vacutainer vials. DISCUSSION The study was conducted to determine the variation of HbA1c value when measured in different anticoagulant vials as against only EDTA advocated by most manufacturers. The study also determines the stability of HbA1c in the different vials when sample were stored at 2-8 o C for 7 days. This study infers that there was no significant variation in the HbA1c values when it was measured in K 3 EDTA, Na-citrate, lithiumheparin and Na-fluoride/Na 2 EDTA vacutainer vials. The study also confirms the stability of HbA1c measurement in the above vials when the samples were stored at 2-8 o C for 7 days. According to 2012 IDF report there are about 54% undiagnosed diabetic in India (1). When it comes to awareness in India only 1/3 rd of diabetics under Improve TM study were aware of HbA1c (9). Even today HbA1c is a very rare test in India, which is because of the cost and lack of standardised laboratory in most part of the country (10). Very recently there is an increase in the numbers of HbA1c test request by the treating physicians. India is a developing economy where almost 70% of the population resides in the rural India. There are seldom any standardised and well-equipped laboratories in rural areas, and sample for testing are often transferred to a nearby town or city for testing after being collected in the rural areas. Sometime even a well-equipped laboratory in remote town has to wait for reagent supply. In these cases the sample for testing has to be stored Page 82

until it could be analysed. It is realised that HbA1c testing is costly and the use of a separate EDTA vacutainer for testing increases the cost further. Often fasting sugar and HbA1c testing are done on the same day, but sample are collected in a Na-fluoride/Na 2 EDTA vial for fasting sugar and an EDTA vial for HbA1c resulting in requirement of more sample volume and extra cost. So, considering these facts our present study seems to very promising when it comes to HbA1c testing. Our study clearly discourages the need for an extra EDTA vial for HbA1c testing, which can be tested in the same Na-fluoride/Na 2 EDTA vial used for fasting / post prandial sugar, or in the same K 2 EDTA vial used for complete blood counts (CBC), or in the same heparin vial in ICU patient used for blood gas analysis. The cost incurred in HbA1c testing will be reduced, the compliance will increase and this in turn will contribute to a better management of diabetes. Our study also reduces the apprehension of the treating physicians regarding the stability of HbA1c test, which are transported to standardised laboratory quite far from the place of sample collection. Physicians can now rely on the reports of HbA1c received and this in turn will generate faith on HbA1c testing in India, resulting in increase request for HbA1c testing. This is very important for a country like India where more people suffer from diabetic complications due to lack of proper monitoring, especially when diabetic complications are found to occur early in India (10, 11, 12). India is a country where proper diabetic screening and adequate manpower like dieticians and field workers for diabetic awareness is lacking, and so the importance of HbA1c testing is even more in India. We also think that HbA1c should also be used for diagnosis of diabetes in India because this could diagnose many cases which go undetected by routine fasting sugar analysis. But before this a pan India HbA1c study should be conducted to establish a base line HbA1c level for Indians, based on which diagnosis and screening could be practiced (13). Until then HbA1c should be done in almost all cases for monitoring of diabetes and in selected cases for diagnosing diabetes in India. Lack of standardised laboratories is a matter of concern and transportation of sample is widely practiced and we see that our study will help gain confidence of patient and treating physician in HbA1c testing in India. HbA1c is very important in diagnosing and monitoring diabetic in a country like India which is considered the diabetic capital of the world. CONCLUSION Our study shows that HbA1c can be measured any of the K 3 EDTA, Na-citrate, lithium-heparin and Na-fluoride/Na 2 EDTA vials without any change in the measured value. So no extra vial is required and which saves lot of money. It also shows that when appropriate cold storage is maintained the sample remains stable for seven days, which is especially important when samples are to be transported for estimation in a place far from the place of collections. ACKNOWLEDGEMENT We are thankful to Dr. V. K. Mahadik, Medical Director of Ujjain Charitable Trust for providing a BioRad D-10 analyser and encouraging us for research in the field of diabetes diagnosis and screening. Authors acknowledge the great help received from the scholars whose articles cited and included in references of this manuscript. The authors are also grateful to authors / editors / publishers of all those articles, journals and books from where the literature for this article has been reviewed and discussed. Authors are grateful to IJCRR editorial board members and IJCRR team of reviewers who have helped to bring quality to this manuscript. Page 83

REFERENCES 1. International diabetic federation, IDF Diabetic atlas, 2012, 5 th edition. Available at: www.idf.org. Accessed December 20 th 2012. 2. Mohan V, Sandeep S, Deepa R, Shah B, Varghese C. Epidemiology of type 2 diabetes: Indian Scenario. Indian Journal of Medical Research 2007; 125: 217-30. 3. Mohan V, Venkatraman JV, Pradeepa R. Epidemiology of cardiovascular disease in type 2 diabetes: The Indian scenario. J Diabetes Sci Technol 2010; 4:58 70. 4. The Diabetes Control and Complications Trial Research Group. The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. N Eng J Med 1993; 329(14):977-86. 5. Diabetes Mellitus : Report of a WHO study Group, Technical Report Series 727, Geneva, World Health Organisation, 1985. 6. American Diabetes Association. Diagnosis and classification of diabetes mellitus. Diabetes Care 2012; 35 (Suppl 1):S64 S71. 7. Sacks DB, Bruns DE, Goldstein DE, Maclaren NK, McDonald JM, Parrott M.Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. Clin Chem 2002; 48:436 472. 8. Little RR, Rohlfing CL, Tennill AL, Connolly S, Hanson S. Effects of sample storage conditions on glycated hemoglobin measurement: evaluation of five different high performance liquid chromatography methods. Diabetes Technol Ther 2007; 9:36 42. 9. Shashank R Joshi, AK Das, VJ Vijay, V Mohan Challenges in Diabetes Care in India: Sheer Numbers, Lack of Awareness and Inadequate Control. JAPI, 2008; 56:443-450. 10. Joshi SR, Das AK, Vijay VJ, Mohan V. Challenges in diabetes care in India: sheer numbers, lack of awareness and inadequate control. J Assoc Physicians India 2008; 56: 443-50. 11. Mohan V, Venkatraman JV, Pradeepa R. Epidemiology of cardiovascular disease in type 2 diabetes: The Indian scenario. J Diabetes Sci Technol 2010; 4:58 70. 12. Raheja BS, Kapur A, Bhoraskar A, Sathe SR, Jorgensen LN, Moorthi SR, et al. Diab Care Asia-India Study: diabetes care in India - current status. J Assoc Physicians India 2001; 49: 717-22. 13. Sarmah D, Sharma B. Importance and Status of HBA1C in T2DM and its Indian Perspective. Asian Journal of Biomedical and Pharmaceutical Sciences 2012; 2 (12), 1-10. Page 84

Figure I: Mean HbA1c% measured for 25 diabetic samples in different anticoagulant vials on day 1, 3, 5 and 7. Figure II: Mean HbA1c% measured for 25 non-diabetic samples in different anticoagulant vials on day 1, 3, 5 and 7. Page 85

Figure III: Correlation showing diabetic HbA1c% measured in the different anticoagulant vials on day 1 and day 7 of testing in the same vials. The graph shows good correlation (r=0.991). Figure IV Figure IV: Correlation showing non-diabetic HbA1c% measured in the different anticoagulant vial on day 1 and day 7 of testing in the same vials. The graph shows good correlation (r=0.957). Page 86