TN-0116 Scott Krepich

Similar documents
APPLICATIONS TN Determination of Sugars in Animal Feed using HPLC-ELSD

APPLICATIONS TN Analytical Method

Run 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1.

A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns

Protect Your Mass Spec

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1

Finally, a Solid Phase Extraction product for Drugs of Abuse

APPLICATIONS TN Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology.

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

APPLICATIONS TN A Sensitive Extraction Method for Nicotine and Metabolites from Urine using Simplified Liquid Extraction (SLE)

Phospholipid Removal Solutions

APPLICATIONS TN Materials and Methods

Labs Across the World Are Advancing Their Protein Precipitation

Core-Shell Technology for Proteins and Peptides

APPLICATIONS Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns

Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases

Rapid Analysis of Synthetic Cannabinoids and their Metabolites in Urine using Solid Phase Extraction and LC/MS/MS. JWH018-4-Hydroxypentyl metabolite

PAIN PANEL. Research and Solutions

Columns The FIRST and ONLY sub-2 µm core-shell columns on the market

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit

For Far. Greater. UHPLC Column Performance You Must Have Kinetex Core-Shell UHPLC Columns.

Preparative Chromatography Meets UHPLC

Keep it Clean with Strata -X

NEW. Kinetex. Biphenyl TMS TMS TMS TMS. Selectivity that a C18 just can t give you!

LC-MS/MS Method for the Determination of Tenofovir from Plasma

METHAMPHETAMINE & AMPHETAMINE

An Easier QuEChERS Solution for Diverse Matrices. Learn more at

Figure 1. Core-Shell Particle Technology

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

SIMPLIFIED CHIRAL SEPARATIONS. Lux Cellulose-1. Guaranteed Alternative. to CHIRALCEL OD-H. Exceptional Quality Sensibly Priced

APPLICATION TN Materials and Methods Reagents and Chemicals

APPLICATIONS TN Rapid Analysis of Hop Acids in Beer using Strata -X Solid Phase Extraction and Kinetex 2.6 µm Core-Shell Technology Column

Keep It Clean. Solid Phase Extraction Solutions for Drugs of Abuse Analysis. Neutral Drugs of Abuse Basic Drugs of Abuse

Sample Concentration and Analysis of Human Hormones in Drinking Water

Supported Liquid Extraction (SLE) For Food Applications

Yes You Can! New! Amazing EVO C18. Core-Shell Technology

Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs. Table 1. List of pain panel drugs

Increasing concentrations of perfluoroalkyl acids in Scandinavian otters (Lutra lutra) between 1972 and 2011 a new threat to the otter population?

PAIN PANEL. Application Guide. Screen 41 compounds in under 4 minutes

High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

Ultivo Applications Terri Sosienski LC/MS Applications Scientist. June 14, 2017

High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS)

Exceed your Purification Goals. Guaranteed. Phenomenex l WEB:

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

Strata-X- NEW! Drug B. Drug B Plus for In-Well Hydrolysis. Simplify Your Solid Phase Extraction.

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

APPLICATION TN Rapid Analysis of a 48 Drug Research Panel in Less Than 4 Minutes Using Kinetex Biphenyl Core-Shell Technology HPLC/UHPLC Columns

Core-Shell Technology. 11 HPLC Myths. Uncovered. & Why You Must Have Kinetex Core-Shell HPLC Columns

APPLICATIONS TN Rapid, High Resolution Analysis of Aflatoxin Extracts from Peanut Butter Using Kinetex Core-Shell Technology and Strata SPE

Robust and Fast Analysis of Tobacco-Specific Nitrosamines by LC-MS/MS

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis

Awesome! Unconventionally. Kinetex EVO C18 HPLC/UHPLC Core-Shell Columns 2.6. Core-Shell Technology

Evaluation of an LC-MS/MS Research Method for the Analysis of 33 Benzodiazepines and their Metabolites

Confidence. A New Standard of. Calibration, Surrogate, & Internal Standards for Environmental Analysis

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis

Quantitative Analysis of THC and Main Metabolites in Whole Blood Using Tandem Mass Spectrometry and Automated Online Sample Preparation

COMBO ULTIMATE HPLC/UHPLC. Kinetex + Luna Omega NEW. Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput

Integration of steroids analysis in serum using LC-MS/MS with full-automated sample preparation

Comparison of Full Scan MS2 and MS3 Linear Ion Trap Approaches for Quantitation of Vitamin D

4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column

LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine

Vitamin Testing APPLICATIONS GUIDE

Providing a Universal, One-step Alternative to Liquid-Liquid Extraction in Bioanalysis

Extraction of Aflatoxin M1 From Infant Formula Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis

Impurity Profiling of Carbamazepine by HPLC/UV

Application Note. Author. Abstract. Introduction. Food Safety

A RAPID AND SENSITIVE ANALYSIS METHOD OF SUDAN RED I, II, III & IV IN TOMATO SAUCE USING ULTRA PERFORMANCE LC MS/MS

Analysis of Per- and Polyfluoroalkyl Substances (PFASs) in Biological Fluid Using a Novel Lipid Removing Sorbent and LC-MS/MS

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No.

NEW Kinetex F5. HPLC/UHPLC Core-Shell Columns

A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS

Semiquantitative Suspect Screening to Assess Poly and Perfluoroalkyl Substances (PFASs) in the Environment

The Investigation of Factors Contributing to Immunosuppressant Drugs Response Variability in LC-MS/MS Analysis

APPLICATIONS TN Determination of Sterols in Olive Oil using Supported Liquid Extraction (SLE), Solid Phase Extraction (SPE) and GC-FID

Separations. Sweet Sugar. Are in Your Future. New. Luna Omega SUGAR LC Column OMEGA

Analysis of Rosuvastatin in Dried Blood Spot and Plasma Using ACQUITY UPLC with 2D Technology

Performance of an ultra low elution volume 96-well plate

Removal of Triton X-100 from Plasma Samples Using Mixed-Mode Solid Phase Extraction (SPE)

Paul Silcock 1, Anna Karrman 2, and Bert van Bavel 2. Aim. Introduction. Sample preparation

Detection of Low Level of Chloramphenicol in Milk and Honey with MIP SPE and LC-MS-MS

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

Per- and polyfluorinated compounds (PFC) analysis of various matrices using UPLC- MS/MS and GC-MS/MS

Reduced Ion Suppression and Improved LC/MS Sensitivity with Agilent Bond Elut Plexa

IC-MS Environmental Applications - Water Testing. Application Notebook

Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs

ApplicationNOTE EXACT MASS MEASUREMENT OF ACTIVE COMPONENTS OF TRADITIONAL HERBAL MEDICINES BY ORTHOGONAL ACCELERATION TIME-OF-FLIGHT.

Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases

Use of a Tandem Mass Spectrometry Research Method for the Analysis of Amino Acids and Acylcarnitines in Dried Blood Spots

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

Dayana Argoti, Kerry Hassell, Sarah J. Fair, and Joseph Herman Thermo Fisher Scientific, Franklin, MA, USA

Protein Precipitation for Biological Fluid Samples Using Agilent Captiva EMR Lipid 96-Well Plates

Determination of Chlorophenoxyacetic Acid and Other Acidic Herbicides Using a QuEChERS Sample Preparation Approach and LC-MS/MS Analysis

Determination of Amantadine Residues in Chicken by LCMS-8040

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry

Fast and easy separation of 23 drugs of abuse. including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS

PFAS Monitoring in a Post Health Advisory World-What Should We Be Doing?

Authors. Abstract. Introduction. Environmental

Transcription:

TN-116 APPLICATIONS Analysis of Perfluorinated Compounds (PFCs) in Aqueous Matrices, Evaluating Various Online SPE Sorbents by LC-MS/MS Scott Krepich Senior Field Application Scientist Scott enjoys surfing and eating. He is crazy about chromatography, because his mom is really into CSI and thinks that is what he does. David Schiessel 1 and Scott Krepich 2 1 BABCOCK Laboratories, Inc, 61 Quail Valley Court, Riverside, CA 9257 USA 2 Phenomenex, Inc., 411 Madrid Avenue., Torrance, CA 951, USA Introduction The analysis of perfluorinated compounds (PFCs) in aqueous matrices, especially drinking water and ground water, has received much attention in recent years. The US EPA has issued health advisories specifically for PFOA and PFOS and the occurrence data from the third Unregulated Contaminant Monitoring Rule (UCMR3) indicates a continuing need for this specific analysis. Using EPA method 537, a 25 ml water sample is fortified with surrogates and passed through a solid phase extraction (SPE) cartridge containing polystyrenedivinylbenzene (SDVB) 1. This extraction is very robust and very sensitive to the low ng/l levels using only 2-1 ul injections. However, method 537 does take a considerable amount of time to perform the SPE because the methanol extract has to be evaporated to dryness and then reconstituted. Online SPE has been shown to be an excellent technique for analyzing aqueous matrices because it bypasses the offline SPE time mentioned previously, increases sample throughput significantly 4, and requires a much smaller sample volume. Additionally, it can be just as sensitive due to the larger injection volume. The performance of three different online SPE sorbents was evaluated for this application; Strata C18-E, Strata-X, and Strata-X-AW. Four PFC analyte classes were evaluated; Perfluoroalkyl acids (PFAAs), Perfluorosulfonates (PFSAs), Perfluorosulfonamidoacetic acids (FOSAAs), and Fluorotelomersulfonates (FTSs). We present data on the pros and cons of each sorbent as well as sensitivity, accuracy, and precision. Materials and Methods Materials LC Column: Kinetex 5 μm EVO C18 1A Dimensions: 1 x 2.1 mm Part No.: D-4633-AN Guard Column: ULTRA Cartridges Part No.: AJ-9298 Online SPE: Strata-X-AW 33 μm Polymeric Weak Anion-Exchange Dimensions: 2 x 2. mm Part No.: M-S38-B-CB Online SPE Cartridge Holder: 2 mm Cartridge Holder Part No.: CH-5845 Sample Filters: Phenex Glass Fiber 1.2 μm 28 mm Part No.: AF-8515-12 Sample Preparation Procedure 1. Samples are collected in polypropylene bottles and preserved with.5 g/l Trizma. 2. A 1 ml aliquot is spiked with surrogates at a concentration of 5 ng/l. 3. If necessary, filter using a 1 ml syringe fitted to a 1.2 μm glass fiber syringe filter. 4. The filtered sample is spiked with internal standard at 5 ng/l. 5. The filtered sample is loaded and analyzed using a 5. ml injection volume. 6. The online SPE is completely automated; it includes a sample wash step (2.1 to 4.1 min) to wash Trizma preservative from the media. Instrumentation LC Pump 1: Thermo Accela 12, Flow 3 μl/min LC Pump 2: Thermo Accela 6 (see table for flow rates) Autosampler Parameters: Transfer Time 25 sec, Elution Time 29 sec Column: Kinetex 5 µm EVO C18 1Å Dimensions: 1 x 2.1 mm Part No.: D-4633-AN Mobile Phase: A:.4 % Ammonium Hydroxide in Water B: Methanol Gradient: Time (min) % B 9 3.1 2 4.5 2 6.1 9 11 9 14 9 Flow Rate:.3 ml/min Temperature: Ambient Detector: Thermo TSQ Quantum Ultra QQQ (MS/MS) HPLC System: Thermo Accela 125 Injection: 5. ml Analytes: 1. Caffeine (2 ppm) 2. Dicyandiamide (2 ppm) 3. Creatinine (4 ppm) 4. Creatine (4 ppm) For additional technical notes, visit www.phenomenex.com Page 1 of 8

TN-116 1 95 9 85 8 75 7 65 6 55 5 45 4 MS Source Parameters: Capillary Temp 15 C Vaporizer Temp 25 C Sheath Gas 4 arb Aux Gas 4 arb ESI Voltage -3.kV Q1 FWHM.7 Da CID Pressure 1.mTorr Argon Column: Kinetex 5 µm EVO C18 1Å Dimensions: 1 x 2.1 mm Part No.: D-4633-AN Mobile Phase: A:.4 % v/v Ammonium Hydroxide in Water B: Methanol Gradient: Time (min) % B 9 3.1 2 4.5 2 6.1 9 11 9 14 9 Flow Rate:.3 ml/min Temperature: Ambient Detector: Thermo TSQ Quantum Ultra QQQ (MS/MS) HPLC System: Thermo Accela 125 Injection: 5. ml Analytes: 1. Caffeine (2 ppm) 2. Dicyandiamide (2 ppm) 3. Creatinine (4 ppm) 4. Creatine (4 ppm) 35 3 25 2 15 1 5 4. 4.5 5. 5.5 6. 6.5 7. 7.5 8. 8.5 9. 9.5 1. min App ID 2442 LC Gradient (pump 1) Time Water MeOH.4 % NH 3. 9 1 3.1 2 2 6 4.5 2 2 6 6.1 9 1 11. 9 1 14. 9 1 Note: To decrease PFOA contributed by the eluent system, MeOH is kept at 9 % while loading the online SPE with sample and subsequently brought down to 2 % 1 min prior to online SPE elution. Online SPE Program (pump 2) Time Water MeOH ACN Flow ml/min Comments. 1 2.5 Sample Loading 2. 1 2.5 Sample Loading 2.1 1 2.5 SPE Wash 4.1 1 2.5 SPE Wash 4.11 3 7 Idle 9. 3 7 Idle 9.1 1 2. ACN Wash 9.49 1 2. ACN Wash 9.5 2. 98 3. MeOH Wash 11.5 2. 98 3. MeOH Wash 11.51 1 3. Cond: Water 14. 1 3. Cond: Water Methanol (MeOH); Acetonitrile (ACN); Ammonia (NH 3 ); Ammonium Hydroxide (NH 4 OH): Ammonium Acetate (NH 4 OAc) Page 2 of 8

TN-116 Table 1. Summary of online SPE and HPLC conditions that were investigated and their performance Options Column Strata SPE Sorbent Sample ph 1 Kinetex EVO C18 5 µm 1 x 2.1 mm SPE Conditioning ph Eluent* PFBA / PFPeA % Shape X-AW Trizma (ph=7) neutral.24-.4 % NH 3 1 excellent 2 3 4 5 6 7 8 9 Kinetex EVO C18 5 µm 5 x 2.1 mm Kinetex EVO C18 5 µm 5 x 2.1 mm Kinetex EVO C18 5 µm 5 x 2.1 mm Luna Omega C18 1.6 µm 5 x 2.1 mm 5 x 2.1 mm 5 x 2.1 mm 5 x 2.1 mm 5 x 2.1 mm X-AW neutral neutral.4 % NH 3 16 very poor X-AW neutral neutral.24-.4 % NH 3 76 OK X-AW acidic neutral.2 % Formic Acid 13 OK C18 neutral neutral 2 mm NH 4 OAc <1 C18 acidic (ph=2) acidic (ph=2).2 % Formic Acid 22 very poor C18 acidic (ph=2) acidic (ph=2) 2 mm NH 4 OAc 11 OK C18 neutral acidic (ph=2) 2 mm NH 4 OAc 11 OK X neutral neutral 2 mm NH 4 OAc 5.9 poor 1 5 x 2.1 mm * Note: All eluents used a gradient of increasing methanol for elution. X acidic neutral 2 mm NH 4 OAc 5.1 poor Figure 1. Online SPE using C18-E sorbent and 2. mm ammonium acetate mobile phase modifier on a Luna Omega C18 LC column. 1 9 8 PFPeA 7 6 5 4 3 2 PFBA 1 1 2 3 4 5 6 7 8 9 1 11 12 13 14 15 16 min Figure 2. Online SPE using Strata-X-AW sorbent and.4-.8 % ammonia mobile phase modifier on a Kinetex C18 EVO LC column (final conditions) 1 9 8 7 6 5 4 3 2 1 PFBA PFPeA 1 2 3 4 5 6 7 8 9 1 11 12 13 14 min Column: Luna Omega 1.6 μm C18 1Å Dimensions: 5 x 2.1 mm Part No.: B-4742-AN Mobile Phase: A: 2 mm Ammonium Acetate in Water B: Methanol Gradient: Time (min) % B 4 4.1 4 6.1 9 13 9 13.1 4 16 4 Injection: 5. ml Flow Rate:.2 ml/min Temperature: 4 C Detector: Thermo TSQ Quantum Ultra QQQ HPLC System: Thermo Accela 125 Column: Kinetex 5 µm EVO C18 1Å Dimensions: 1 x 2.1 mm Part No.: D-4633-AN Mobile Phase: A:.4 % v/v Ammonium Hydroxide in Water B: Methanol Gradient: Time (min) % B 9 3.1 2 4.5 2 6.1 9 11 9 14 9 Injection: 5. ml Flow Rate:.3 ml/min Temperature: Ambient Detector: Thermo TSQ Quantum Ultra QQQ HPLC System: Thermo Accela 125 For additional technical notes, visit www.phenomenex.com Page 3 of 8 App ID 24388 App ID 24376

TN-116 Figure 3. Elution strength of.4 % NH 3 (left) and.24 % NH 3 (Right) illustrating more efficient elution of analytes (PFBA and PFPeA) with increased base concentration in the mobile phase. 1 8 6 4 2 PFBA PFPeA 1 8 6 4 2 PFBA PFPeA 2 4 6 8 1 12 14 16 min 2 4 6 8 1 12 min Figure 4. Effect of filtering on recovery of long chain PFCs. Unfiltered GF Filtered RC Filtered 1 8 6 4 2 1 8 6 4 2 1 8 6 4 2 1 8 6 4 2 7. 7.5 8. 8.5 9. Time (min) 7.5 8. 8.5 9. Time (min) 7.5 8. 8.5 9. Time (min) Page 4 of 8

TN-116 Figure 5. LCMRL plot of PFOA and PFOS showing the relationship of the data to the predicted limits. The LCMRL is the highest value of the upper and lower prediction limit intersection points with the 5-15 % criteria. Results & Discussion One of the first objectives was to find the best SPE sorbent that would cover the target analytes. Table 1 summarizes the options that were investigated. It quickly became apparent during development that the earliest eluter (lowest molecular weight) analyte was to be the indicator of SPE performance. As such the relative responses of PFBA and PFPeA were tabulated as well as the peak shape in order to meet data quality objectives similar to EPA method 537. The peak shape of the first 2 eluting peaks is addressed in EPA method 537 with a requirement for peak asymmetry factor. It should be noted (lines 1 and 3 in the table) that the Trizma preservative marginally improved the PFBA relative to PFPeA. It was experimentally determined that the same elution conditions- (Methanol and 2. mm NH 4 OAc) used for C18 or Strata -X online SPE could not work on the Strata-X-AW. Incidentally the mechanism used in weak anion-exchange (high ph elution) is quite different than the one employed using C18. Due to limitations on standard silica C18 analytical columns and online SPE, which typically cannot operate at high ph, a different approach was chosen. The analytical column chosen was a Kinetex EVO C18 5 x 2.1 mm due to its extended ph operability range. This does result in some retention time differences when comparing the analytical systems. For this reason and due to variability associated with electrospray ionization, response was evaluated relative to other analytes to evaluate performance. The Strata-X-AW provided a significant improvement in trapping smaller chain PFCs. Figure 1 shows a chromatogram of PFBA (6.71 min) and PFPeA (7.61min) using a C18 online SPE cartridge and 2. mm ammonium acetate. Note that the response of PFBA is 11 % of the PFPeA response using C18 however this value rises noticeably to 76 % when using Strata-X-AW (Figure 2). This seems to be a simple limitation of using C18 for small organic acids even if the sample is acidified. The same effect was observed for the sulfonates PFBS and PFHxS, but to a lesser degree. Another aspect of this analysis that was investigated was the ability to filter aqueous samples. This has a direct effect on whether the method could be adapted to aqueous soil extracts. Two types of filters were evaluated; glass fiber (Phenex GF) and regenerated cellulose (Phenex RC). The biggest impact filtering has on analytes is with longer chain PFCs like PFDoDA, PFTrDA, PFTeDA, and PFDS. Figure 4 is a comparison between unfiltered, glass fiber filtration, and regenerated cellulose filtration (left to right). For additional technical notes, visit www.phenomenex.com Page 5 of 8

TN-116 Table 2. Performance comparison of the online SPE (Strata -X-AW) method with EPA 537. Analyte Online SPE LCMRL Online SPE DL EPA537 LCMRL* EPA537 DL** PFBA 9.8 1.4 - - PFPeA 5.9.9 - - PFHxA 1.4.9 2.9 1.6 PFHpA 5..5 3.8.5 PFOA 3.4 2. 5.1 1.7 PFNA 3.5.8 5.5.7 PFDA 11 1.2 3.8.7 PFUnDA 14 1.2 6.9 2.8 PFDoA 17 2.5 3.5 1.1 PFTrDA 12 3.3 3.8 2.2 PFTeDA 12 2.1 4.7 1.7 PFBS 6.3 1.6 3.7 3.1 PFHxS 5.5 1.5 8. 2. PFHpS 6.5 1.8 - - PFOS 4.9 3.2 6.5 1.4 PFDS 11 4.5 - - 6:2-FTS 4.1.8 - - 8:2-FTS 5.1 1.7 - - N-MeFOSAA 14 2.7 14 6.5 N-EtFOSAA 12 3.2 14 4.2 * LCMRL is the lowest concentration minimum reporting level 6 ** DL is the detection limit 6 Conclusion Balancing the performance across the wide range of analytes, the Strata-X-AW provides the most robust online SPE, especially if short chain PFCs are of interest. To assess performance as compared to EPA 537 methodology using the Strata-X-AW, a LCMRL (lowest concentration minimum reporting level) study was performed in Trizma preserved water to determine the lowest concentration at which an accuracy of 5-15 % can be achieved with a confidence of 99 %. Additionally, a DL (detection limit) study was performed to determine the lowest concentration at which an analyte can be detected with a 99 % confidence without an accuracy limit. The results of this study are listed in Table 2 along with results from EPA method 537. While all 3 SPE sorbents evaluated could be used for PFC analysis, the Strata-X-AW shows markedly improved recoveries for the widest analyte class. This is not surprising considering offline SPE using weak anion-exchange is fairly robust in other matrices 2,3. However, if only certain priority PFCs are required such as PFOA and PFOS, C18 would provide adequate peak shape and recovery. One caveat with this system is that the sample ph should be adjusted to 2 using formic acid and the sorbent should be conditioned using.2 % formic acid. This provides sufficient strength to protonate and trap analytes. With the advent of analytical columns like the Kinetex EVO C18 core-shell that can support a higher ph, it s possible to couple weak anion-exchange online SPE to a suitable analytical column. Additionally, the use of aqueous ammonia in the eluent has no limitingfactors when coupled to MS due to its volatility and preliminary data show that ammonia provides better ionization than ammonium acetate. Glass fiber filters can allow samples to be filtered without detrimentally affecting performance. This makes it possible to further expand the applicability of the method. For example, one method of extracting PFCs from soil uses methanol followed by SPE cleanup 5. It s quite possible that a large volume (.5-1. ml) of methanol could be filtered using glass fiber, diluted with water, and pre-concentrated using a Strata-X-AW as described above. Preliminary tests show that up to 1 % methanol can be injected onto Strata-X-AW before the high organic starts affecting the smallest acids (i.e.: PFBA). Acknowledgements We would especially like to thank David Schiessel and BABCOCK Laboratories for developing and contributing this application. References 1. EPA Method 537 v1.1, Determination Of Selected Perfluorinated Alkyl Acids In Drinking Water By Solid Phase Extraction And Liquid Chromatography/ Tandem Mass Spectrometry (LC/MS/MS), September 29. 2. Zhang Y, Tan D, Geng Y, et al. Perfluorinated Compounds in Greenhouse and Open Agricultural Producing Areas of Three Provinces of China:Levels, Sources and Risk Assessment. Ahmed W, Beale DJ, eds. International Journal of Environmental Research and Public Health. 216;13(12):1224. doi:1.339/ijerph13121224. 3. Yamazaki, Eriko, Sachi Taniyasu, Kodai Shimamura, Shunya Sasaki, and Nobuyoshi Yamashita. Development of a Solid-Phase Extraction Method forthe Trace Analysis of Perfluoroalkyl Substances in Open-Ocean Water. Bunseki Kagaku 64, no. 1 (215): 759 68. doi:1.2116/bunsekikagaku.64.759. 4. Bersuker, I.B. Electronic Structure and Properties of Transition Metal Compounds: Introduction to the Theory; Wiley & Sons: New York, 1996; Chapter 4. EPA Method 543 v1., Determination of Selected Organic Chemicals in Drinking Water by On-line Solid Phase Extraction - Liquid Chromatography/ Tandem Mass Spectrometry (On-line SPE - LC/MS/MS), March 215. 5. Strynar, Mark J., Andrew B. Lindstrom, Shoji F. Nakayama, Peter P. Egeghy, and Laurence J. Helfant. Pilot Scale Application of a Method for the Analysis of Perfluorinated Compounds in Surface Soils. Chemosphere 86, no. 3 (January 212): 252 57. doi:1.116/j.chemosphere.211.9.36. 6. Martin, John J., Stephen D. Winslow, and David J. Munch. A New Approach to Drinking-Water-Quality Data: Lowest-Concentration Minimum Reporting Level. Environmental Science & Technology 41, no. 3 (February 27): 677 81. doi:1.121/es72456n Page 6 of 8

TN-116 Ordering Information Kinetex EVO C18 Core-Shell LC Columns 5 μm Minibore Columns (mm) 3 x 2.1 5 x 2.1 1 x 2.1 15 x 2.1 3/pk A-4633-AN B-4633-AN D-4633-AN F-4633-AN AJ-9298 for 2,1 mm ID 5 μm MidBore Columns (mm) 5 x 3. 1 x 3. 15 x 3. 3/pk B-4633-Y D-4633-Y F-4633-Y AJ-9297 for 3, mm ID 5 μm Analytical Columns (mm) 5 x 4.6 1 x 4.6 15 x 4.6 25 x 4.6 3/pk B-4633-E D-4633-E F-4633-E G-4633-E AJ-9296 for 4,6 mm ID 2.6 μm Minibore Columns (mm) 3 x 2.1 5 x 2.1 1 x 2.1 15 x 2.1 3/pk A-4725-AN B-4725-AN D-4725-AN F-4725-AN AJ-9298 for 2,1 mm ID 2.6 μm MidBore Columns (mm) 5 x 3. 1 x 3. 15 x 3. 3/pk B-4725-Y D-4725-Y F-4725-Y AJ-9297 for 3, mm ID 2.6 μm Analytical Columns (mm) 5 x 4.6 1 x 4.6 15 x 4.6 3/pk B-4725-E D-4725-E F-4725-E AJ-9296 for 4,6 mm ID 1.7 μm Minibore Columns (mm) 5 x 2.1 1 x 2.1 15 x 2.1 3/pk B-4726-AN D-4726-AN F-4726-AN AJ-9298 for 2,1 mm ID ULTRA Cartridges require holder, Part No.: AJ-9 Luna Omega LC Columns 1.6 μm Microbore Columns (mm) Phases 5 x 1. 1 x 1. 15 x 1. C18 B-4742-A D-4742-A F-4742-A 1.6 μm Minibore Columns (mm) Phases 3 x 2.1 5 x 2.1 1 x 2.1 15 x 2.1 3/pk C18 A-4742-AN B-4742-AN D-4742-AN F-4742-AN AJ-952 for 2.1 mm ID 3 μm Minibore Columns (mm) Cartridges (mm) Phases 3 x 2.1 5 x 2.1 1 x 2.1 15 x 2.1 4 x 2.* PS C18 A-4758-AN B-4758-AN D-4758-AN F-4758-AN AJ-765 for ID: 2. - 3. mm Strata SPE Ordering Information On-line Extraction Cartridge Description Part Number Unit/Box Strata-X on-line extraction cartridge, 2 x 2. mm M-S33-B-CB ea Strata-X-AW online extraction cartridge, 2 x 2. mm M-S38-B-CB ea Strata C18 online extraction cartridge, 2 x 2. mm M-S39-CB ea Cartridge holder, 2 mm CH-5845 ea If Phenomenex products in this technical note do not provide at least an equivalent separation as compared to other products of the same phase and dimensions, return the product with comparative data within 45 days for a FULL REFUND. For additional technical notes, visit www.phenomenex.com Page 7 of 8

TN-116 APPLICATIONS Australia t: +61 ()2-9428-6444 f: +61 ()2-9428-6445 auinfo@phenomenex.com Austria t: +43 ()1-319-131 f: +43 ()1-319-13 anfrage@phenomenex.com Luxembourg t: +31 ()3-24187 f: +31 ()3-2383749 nlinfo@phenomenex.com Mexico t: 1-8-844-5226 f: 1-31-328-7768 tecnicomx@phenomenex.com Belgium t: +32 ()2 53 415 (French) t: +32 ()2 511 8666 (Dutch) f: +31 ()3-2383749 beinfo@phenomenex.com Canada t: +1 (8) 543-3681 f: +1 (31) 328-7768 info@phenomenex.com China t: +86 4-66-899 f: +86 ()22 2532-133 phen@agela.com Denmark t: +45 4824 848 f: +45 481 6265 nordicinfo@phenomenex.com Finland t: +358 ()9 4789 63 f: +45 481 6265 nordicinfo@phenomenex.com France t: +33 ()1 3 9 21 1 f: +33 ()1 3 9 21 11 franceinfo@phenomenex.com Germany t: +49 ()621-5883- f: +49 ()621-5883-11 anfrage@phenomenex.com India t: +91 ()4-312 24 f: +91 ()4-312 2411 indiainfo@phenomenex.com Ireland t: +353 ()1 247 545 f: +44 1625-51796 eireinfo@phenomenex.com Italy t: +39 51 6327511 f: +39 51 6327555 italiainfo@phenomenex.com www.phenomenex.com Phenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at international@phenomenex.com Page 8 of 8 The Netherlands t: +31 ()3-24187 f: +31 ()3-2383749 nlinfo@phenomenex.com New Zealand t: +64 ()9-478951 f: +64 ()9-478952 nzinfo@phenomenex.com Norway t: +47 81 2 5 f: +45 481 6265 nordicinfo@phenomenex.com Puerto Rico t: +1 (8) 541-HPLC f: +1 (31) 328-7768 info@phenomenex.com Spain t: +34 91-413-8613 f: +34 91-413-229 espinfo@phenomenex.com Sweden t: +46 ()8 611 695 f: +45 481 6265 nordicinfo@phenomenex.com United Kingdom t: +44 ()1625-51367 f: +44 ()1625-51796 ukinfo@phenomenex.com USA t: +1 (31) 212-555 f: +1 (31) 328-7768 info@phenomenex.com All other countries Corporate Office USA t: +1 (31) 212-555 f: +1 (31) 328-7768 info@phenomenex.com Terms and Conditions Subject to Phenomenex Standard Terms and Conditions, which may be viewed at http://www.phenomenex.com/termsandconditions. Trademarks Kinetex, Strata, and Luna are registered trademarks and, MercuryMS and Phenex are trademarks of Phenomenex. Thermo Scientific, Accela, and TSQ Quantum are trademarks of Thermo Fisher Scientific.Trizma is a registered trademark of Sigma-Aldrich Co. Disclaimer Phenomenex is not affiliated with Thermo Fisher Scientific. 217 Phenomenex, Inc. All rights reserved. TN5379617_W