LINEAR 7.5Fr. IAB Catheter

Similar documents
LINEAR. 7.5Fr. IAB Catheter. This document is intended to provide information to an international audience outside of the US.

SENSATION and CS300 Smaller meets faster. IABP System

HLS Cannulae Solutions from tip to tip.

HLS Cannulae Solutions from tip to tip.

HLS CANNULAE SOLUTIONS FROM TIP TO TIP

ER REBOA Catheter. Instructions for Use

Galt Medical Corp. A leader in vascular and interventional medical devices. part of the GaltNeedleTech TM Family

i INTERACTIVE CATALOG FIND YOUR IDEAL CANNULAE

LINEAR. 7.5Fr. IAB CATHETER INSTRUCTIONS FOR USE. INSTRUCTIONS FOR USE LINEAR 7.5Fr. Intra-Aortic Balloon Catheter 1

The next step in dialysis catheter technology

RECOMMENDED INSTRUCTIONS FOR USE

MAXIMIZE RADIAL SOLUTIONS TO PERIPHERAL CHALLENGES

SMOOTH VASCULAR ACCESS COMPARATIVE BENCH TOP RESULTS

CLAMPLESS BEATING HEART SURGERY PRODUCT FAMILY

Cardioplegia Circuit Products { ANTEGRADE}

Quick Reference Guide

Advanced Innovation for Exceptional Performance

Polyurethane Dual Lumen Occlusion Catheter English Instructions for Use. Polyurethane Dual Lumen Occlusion Catheter

DIGESTIVE HEALTH ENTERAL FEEDING PRODUCTS

DISCOVER NEW HORIZONS IN FLUID DRAINAGE. Bringing Safety and Convenience to Fluid Drainage Management

MICS & FEMORAL CANNULAE

CLARIVEIN INFUSION CATHETER

Arrow Cannon II Plus Retrograde-tunneled, Tip-first Chronic Hemodialysis Catheter

NON-COMPLIANT PTCA RAPID EXCHANGE DILATATION CATHETER

XEMEX IABP Balloon Plus

High Flow Family. Short Term Dialysis Catheters. Dialysis

Veterinary Products Catalog. I.V. Catheters Needles Syringes Winged Infusion Sets

Pruitt Irrigation Occlusion Catheter. English Instructions for Use. Pruitt Irrigation Occlusion Catheter

Advancing Lives and the Delivery of Health Care. The High-Flow Port Designed for Apheresis

CLINICAL SUPPORT SERVICES DEVELOPING AN IABP PRECEPTOR STRATEGY

Peel-Apart Percutaneous Introducer Kits for

Indications. The AngioVac cannula is intended for use as a venous drainage cannula and for the removal of fresh, soft thrombi or emboli

Thora-Para catheter drainage systems

Atrium Advanta V12. Balloon Expandable Covered Stents

INNOVATIVE PRODUCTS G, J AND GJ-TUBES WITH ENFit TM CONNECTION

A CATHETER FAMILY FOR ALL YOUR PATIENT NEEDS

Directions For Use. All directions should be read before use

CP STENT. Large Diameter, Balloon Expandable Stent

Protecting Patients. Preserving Access.

Balloon in Balloon (BIB )

PTA Balloon Dilatation Catheter

arrow nextstep antegrade & Arrow Edge The next step in dialysis catheter technology

FIND YOUR IDEAL CANNULAE CATALOG. Designed for your smallest patients

PTA Balloon Dilatation Catheter

Cook Medical. Zenith Flex AAA Endovascular Graft with Z-Trak Introduction System Physician Training

CATHETER ACCESS KIT. For use with Prometra Programmable Infusion Systems

IABP Timing & Fidelity. Pocket Reference Guide

ASAHI Corsair INSTRUCTIONS FOR USE

Z-MED II BALLOON AORTIC AND PULMONIC VALVULOPLASTY CATHETER. Instructions for Use

Balloon in Balloon (BIB )

AXS Catalyst Distal Access Catheter

Integra Flowable Wound Matrix

I SEE THE BROADEST RANGE OF PRODUCTS THRU my smallest possible incision.*

The Art of. Flow Restoration. Ikazuchi Zero. Semi-Compliant PTCA Balloon OVERVIEW CROSSABILITY LOW PROFILE CASE STUDY CODES

PORTS SETTING THE STANDARD WITH A COMPREHENSIVE FAMILY OF PORTS

ASEPT. Pleural Drainage System INSTRUCTIONS FOR USE REF LOT STERILE EO. Manufactured for: 824 Twelfth Avenue Bethlehem, PA

LeMaitre Embolectomy Catheter

The SplitWire Percutaneous Transluminal Angioplasty Scoring Device. Instructions for Use

Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully

Designed to Reduce the Risk of Occlusion (1)

Ureteroscopy solutions for your most challenging cases.

Protecting Patients. Preserving Access.

Better Post-Op Pain Control Starts Here

ASEPT Pleural Drainage System

ROTABLATORTM. Peripheral. Rotational Atherectomy System. Quick Reference Cards

Cardioplegia Circuit Products { CARDIOPLEGIA ADAPTERS}

Peripheral Intravascular Lithotripsy (IVL) Catheter Instructions for Use (IFU)

22F coil-reinforced cannula. Designed with a balloon actuated, expandable funnel shaped distal tip

JETSTREAM Atherectomy System DELIVERING VERSATILITY TO RESTORE FLOW

Catheters and Wires. Dr. Vaibhav Jain MD,DNB,MNAMS Senior Consultant, IR Medanta, the Medicity, Gurgaon

ISO INTERNATIONAL STANDARD. Sterile single-use intravascular catheter introducers

The I.V. Catheter Family

MARKING RING VEIN GRAFT VALVE INSTRUMENTS. Hook, Valve. TFX SURGICAL SPECIALTIES Phone Toll Free: Fax:

Isn t it worth two bags?

Instruction for use of Foley Catheter

Safe-T-Centesis catheter drainage system. Innovations in patient safety, clinician safety and procedural efficacy.

Arrow AC3 Optimus Intra-Aortic Balloon Pump Greater precision with increased simplicity; an evolution in IABP performance

Arrow AC3 Optimus Intra-Aortic Balloon Pump Greater precision with increased simplicity; an evolution in IABP performance

2018 CANNULAE CATALOGUE

Directions For Use. All directions should be read before use. Page 1 of 8

CONVENTIONAL ADULT CANNULAE

CONVENTIONAL ADULT CANNULAE

Exceptional Performance and Ease of Placement

Instructions for Use 1

Radux StandTall Instructions for Use Sheath Extender and Securement Clasp

NIRxcell CoCr Coronary Stent System

The High-Flow Port Designed & Indicated for Apheresis

ASEPT. Pleural Drainage System INSTRUCTIONS FOR USE. Rx only REF LOT. STERILE EO Sterilized using ethylene oxide

1 Description. 2 Indications. 3 Warnings ASPIRATION CATHETER

Global Myocardial Protection

Initial placement 24FR Pull PEG kit REORDER NO:

Endorectal Balloon (ERB) Endorectal Balloon (ERB) Instructions for Use

Navigate Complex Interventions at Every Turn

ARROW ENDURANCE. Extended Dwell Peripheral Catheter System. Rx only.

Part 1: General requirements

Challenging anatomies demand versatility.

Solitaire FR Revascularization Device

Integra. TenoGlide Tendon Protector Sheet SURGICAL TECHNIQUE

Intravascular catheters Sterile and single-use catheters. Part 5: Over-needle peripheral catheters

Peritoneal Drainage System

Transcription:

LINEAR 7.5Fr. IAB Catheter

The LINEAR 7.5Fr. Catheter Easier to insert* Proprietary IAB Membrane provides better performance* Abrasion resistance improved 43%* Improved fatigue resistance* Immediate inflation at start-up* Reduced insertion force* Abrasion resistance* in different membranes 4.5 4 3.5 1.10 1.00.90.80.70 Insertion force reduced by 43%* % 3 2.5 2 1.5 1 0.5 LBS.60.50.40.30.20.10 0 LINEAR 7.5Fr. Proprietary IAB Membrane Competitor Cardiothane II 0 LINEAR 7.5Fr. Competitor 7.5Fr. The smaller 7.5Fr. size is ideal for small adults, diabetics, and patients with PVD* Reduced catheter cross section area by 12% vs. 8Fr.* Artery Lumen Smaller catheter size allows increased distal limb flow Minimize the size of arterial puncture Ease of insertion in smaller or diseased vessel lumens LINEAR IAB catheter has 43% reduction in insertion forces compared to Competitor 7.5Fr. IAB catheter* 8Fr. (Drawing not to scale) LINEAR 7.5Fr. Catheter Increased space for distal flow

We weren t satisfied to make it smaller We had to make it better Smaller profile without compromised performance* Faster gas shuttle performance allows better support of rapid heart rates and arrhythmias LINEAR has 19% faster cycle time in 80º bend test method compared to competitive IAB catheters* 600 500 Linear 7.5Fr. Displayed faster cycle time* Improved sheath Improved sheath to introducer transition Hemostasis valve Twist lock introducer hub Universal color coding for size Wire reinforced sheath Cycle Time (msec) 400 300 200 100 Deflation Inflation Old design introducer transition 0 LINEAR 7.5Fr. Competitor LINEAR 7.5Fr. features improved sheath-tointroducer transition T-Handle protector for balloon membrane Keeps the membrane tightly wrapped prior to insertion Helps to handle catheter prior to insertion T-Handle protector simplifies handling of catheter Twist lock introducer hub prevents accidental separation

Technical specifications:* LINEAR 7.5Fr. IAB catheter with insertion kit Balloon Item Number Nominal Volume (cc) Nominal Length (mm) Balloon Dia. at 2 psi (mm) Insertable Length (mm) Pressure Lumen ID Size (in.) Guidewire Size (in.) 0684-00-0480-01U 40 258 15.0 723 0.027 0.025 0684-00-0479-01U 34 221 15.0 723 0.027 0.025 0684-00-0478-01U 25 165 15.0 723 0.027 0.025 Ordering Information Configuration Description 40cc LINEAR 7.5Fr. IAB Catheter with Catheter Extender 40cc LINEAR 7.5Fr. IAB Catheter with Arrow Pump Adapter 34cc LINEAR 7.5Fr. IAB Catheter with Catheter Extender 34cc LINEAR 7.5Fr. IAB Catheter with Arrow Pump Adapter 25cc LINEAR 7.5Fr. IAB Catheter with Catheter Extender 25cc LINEAR 7.5Fr. IAB Catheter with Arrow Pump Adapter 40cc and 34cc Insertion Kit includes : 6" (15cm) Reinforced Sheath Introducer with hemostasis valve and Introducer Dilator One 18 gauge Angiographic Needle, One Vessel Dilator One 0.025" X 145cm 3mm J PTFE Stainless Steel Guidewire One 6 ft. Catheter Extender (40cc and 34cc only) One Male Luer Cap One Three-Way Stopcock Two 4 ft. (122cm) Pressure Tubings 25cc Insertion Kit includes: Above contents and One 5 ft. Catheter Extender Item Number 0684-00-0480-01U 0684-00-0480-02U 0684-00-0479-01U 0684-00-0479-02U 0684-00-0478-01U 0684-00-0478-02U 0884-00-0019-13 0884-00-0019-12 Materials All balloon and catheter materials meet FDA and ISO biocompatibility guidelines for devices and materials. LINEAR 7.5Fr. IAB catheters and insertion kits do not contain latex. Packaging Single Pouch, Corner Peel Cycle Life 1 procedure Shelf Life 3 years from date of sterilization All parameters specified at 25 C ambient temperature. Maquet maintains a policy of continual product improvement and reserves the right to change materials and specifications without notice. 0.025" X 145cm 3mm J PTFE Stainless Steel Guidewire (Box of 5) 0684-00-0254-09 0.025" X 175cm 3mm J PTFE Stainless Steel Guidewire (Box of 5) 0684-00-0254-14 0.025" X 260cm 3mm J PTFE Stainless Steel Guidewire (Box of 5) 0684-00-0254-15 Arrow Pump Adapter 5PK (25cc to 40cc) 0684-00-0510-01 7.5Fr. Sheath and Dilator Set 0684-00-0403-05 Catheter Extender for 40cc and 34cc IABs only (Box of 10) 0684-00-0186 Catheter Extender for 25cc only (each) 0684-00-0325 *Data on file

Maquet offers a range of convenient and innovative clinical solutions for counterpulsation therapy, such as our LINEAR 7.5Fr. intra-aortic balloon catheter product line. We weren t satisfied to make a smaller shaft catheter, we also had to make it perform better than the competition and our previous product lines. Maquet created a Proprietary IAB Membrane so it can stand up to your most difficult patients. It s stronger, more durable, yet thinner than any previous IAB membrane. Our Proprietary IAB Membrane patented blow-molded polyurethane material has been developed to withstand the constant abrasion of even the most calcified aortas. Yet it is so thin, it allows us to make far less invasive catheters. Maquet The Gold Standard

Maquet Medical Systems USA 45 Barbour Pond Drive, Wayne, NJ 07470, USA Phone: 1 888 880 2874 Maquet 1300 MacArthur Blvd., Mahwah, NJ 07430, USA Phone: +1 201 995 8700 or 1 800 777 4222 www.maquet.com Getinge Group is a leading global provider of products and systems that contribute to quality enhancement and cost efficiency within healthcare and life sciences. We operate under the three brands of ArjoHuntleigh, Getinge and Maquet. ArjoHuntleigh focuses on patient mobility and wound management solutions. Getinge provides solutions for infection control within healthcare and contamination prevention within life sciences. Maquet specializes in solutions, therapies and products for surgical interventions, interventional cardiology and intensive care. PN: 0002-08-0598-US R1 Maquet is a registered trademark of Maquet GmbH LINEAR is a U.S. registered trademark of Datascope Trademark Corp. Copyright 2014 Datascope Corp. or its affiliates All rights reserved 08/14 Caution: Federal (U.S.A.) Law restricts this device to sale by or on the order of a physician. Refer to Instructions for Use for current indications, warnings, contraindications, and precautions. MCV00026807 REVB