Patients commonly arouse from sleep and experience awake states.

Similar documents
Clinical Technologies

SensAwake. Responsive Pressure Relief

A simple solution for your complex patients

Improving Care & Outcomes

The intelligent solution. System One Sleep Therapy System uses advanced intelligence to deliver excellent care while making patient management easy

One intelligent solution

Goldman Sachs JBWere Australasian Investment Forum New York - 7 March 2006

One intelligent solution

Natural performance. Introducing the BiPAP A30 - because ease of use and therapy efficacy are key to patient well-being

FY07 Full Year Update & Overview

DIGITAL AUTO-TRAK + Bi-FLEX + AUTO Bi-LEVEL THE POWER OF. Sometimes when three come together the results can be quite extraordinary. Unique even.

Investment Highlights

FY06 Full Year Update & Overview

XT series. Continuous Positive Airway Pressure

Health Care Providers:

Global Continuous Positive Airway Pressure(CPAP) Devices Market Research Report - Forecast to 2027

THE NEW HOME FOR C-FLEX IS BUILT ON THE IDEA THAT A BETTER NIGHT S SLEEP COMES FROM PRODUCTS THAT ARE EASY TO USE.

Fisher & Paykel Healthcare

a new beginning in managing CSA ResMed.com/AirSolutions

Performance. Connectivity. Comfort. A Breath of Innovation

The International Palestinian Congress in Sleep Medicine

Full Year Update FY2011 May 2011

Effective Treatment for Obstructive Sleep Apnoea

Equivalence of Nasal and Oronasal Masks during Initial CPAP Titration for Obstructive Sleep Apnea Syndrome

Therapy guide. A simple guide to managing your treatment of Obstructive Sleep Apnea

Half Year Update FY2012 November 2011

Infant Invasive Ventilation. Clinical Paper Summaries

Comparative Efficacy of Two Expiratory Pressure Reduction Systems in the Treatment of Obstructive Sleep Apnea

PEDIATRIC PAP TITRATION PROTOCOL

Provider guide. DreamStation CPAP DreamStation CPAP Pro DreamStation Auto CPAP DreamStation BiPAP Pro DreamStation Auto BiPAP

Titration protocol reference guide

During the therapeutic titration of nasal continuous

Effective Treatment for Obstructive Sleep Apnoea

2014 Full Year Results Presentation. Year ended 31 March 2014

Positive Airway Pressure and Oral Devices for the Treatment of Obstructive Sleep Apnea

COMPLEX SLEEP APNEA IS IT A DISEASE? David Claman, MD UCSF Sleep Disorders Center

Positive Airway Pressure and Oral Devices for the Treatment of Obstructive Sleep Apnea

For personal use only

For personal use only

For personal use only

NON-INVASIVE VENTILATION MADE RIDICULOUSLY SIMPLE

Finally, CPAP you can sleep with OPEN FOR MORE

CPAP/BPAP AND DIAGNOSTIC SLEEP LABS

Pap Settings. A review of fine tuning settings For patient comfort and compliance Wendy Cook BSRT Judy Salisbury RPGST

Data Management of the Sleep Disordered Breathing Patient

Wake up to Life. with ResMed s advanced sleep therapy system.

Positive Pressure Therapy

Provider guide. DreamStation

Persistence of Upper-Airway Symptoms During CPAP Compromises Adherence at 1 Year

All About Positive Airway Pressure (PAP) Therapy

DreamStation. Provider guide

GE Healthcare. Non Invasive Ventilation (NIV) For the Engström Ventilator. Relief, Relax, Recovery

Noninvasive Mechanical Ventilation in Children ศ.พญ.อร ณวรรณ พฤทธ พ นธ หน วยโรคระบบหายใจเด ก ภาคว ชาก มารเวชศาสตร คณะแพทยศาสตร โรงพยาบาลรามาธ บด

Index. sleep.theclinics.com. Note: Page numbers of article titles are in boldface type.

Pediatric Sleep-Disordered Breathing

OSA and COPD: What happens when the two OVERLAP?

Titration protocol reference guide

Management of OSA. saurabh maji

Sleep Apnea Therapy Device

SUBURBAN LUNG ASSOCIATES, S.C. 800 Biesterfield Road, Suite 510 Elk Grove Village, IL 60007

Autotitrating CPAP: Interpreting Studies

(To be filled by the treating physician)

Precision Sleep Medicine

New Government O2 Criteria and Expert Panel. Jennifer Despain, RPSGT, RST, AS

What is an APAP Machine?

TNI 20: Breathe Easier without a Mask

Questions: What tests are available to diagnose sleep disordered breathing? How do you calculate overall AHI vs obstructive AHI?

WHAT DO YOU WANT FROM A HOME VENTILATION SYSTEM? 8322_RS_HomeNIV_brochure_v14.ind1 1 4/7/06 12:57:35

Inspire Therapy for Sleep Apnea

Financial Presentation

Philip L. Smith, MD; Christopher P. O Donnell, PhD; Lawrence Allan, BS; and Alan R. Schwartz, MD

Chronic NIV in heart failure patients: ASV, NIV and CPAP

Disclosures. Michael Gunnuscio RPSGT, Bob Chase RRT, Umakanth Khatwa MD

medical products, serving patients from the hospital to the home.

Policy Specific Section: October 1, 2010 January 21, 2013

Auto Servo Ventilation Indications, Basics of Algorithm, and Titration

ResScan Report Interpretation Guide. FOR CLINICAL USE ONLY V1.0 June, 2011

Equivalence of Autoadjusted and Constant Continuous Positive Airway Pressure in Home Treatment of Sleep Apnea*

CPAP Sales PRODUCT .. BROCHURE ~ INFORMATION. Making a Great Nights' Sleep Affordable

A 74-year-old man with severe ischemic cardiomyopathy and atrial fibrillation

POLICY All patients will be assessed for risk factors associated with OSA prior to any surgical procedures.

Joel Reiter*, Bashar Zleik, Mihaela Bazalakova, Pankaj Mehta, Robert Joseph Thomas

Mario Kinsella MD FAASM 10/5/2016

Oventus: Innovators in Sleep Apnoea Treatment Investor lunch presentation Tattersall s Club, Brisbane

About VirtuOx. Was marketed exclusively by Phillips Healthcare division, Respironics for 3 years

Sept ibreeze+ Series. Redefine your premium CPAP

Lumis Tx: the all-in-one hospital ventilation solution

1 2 3 Based on the contents detailed below, assess the substantial equivalence to a legally marketed predicate device. In that case, the standards, et

Titration and monitoring of CPAP in infants

WILAflow Elite Neonatal Ventilator. Non-invasive treatment for the most delicate patients.

Web-Based Home Sleep Testing

A New, Clinically Proven Sleep Apnea Therapy for people unable to use CPAP.

National Sleep Disorders Research Plan

For personal use only

Tired of being tired?

A new beginning in therapy for women

Pocket Guide. System One REMstar Pro and REMstar Auto

Inspire Therapy for Sleep Apnea

Positive Airway Pressure and Oral Devices for the Treatment of Obstructive Sleep Apnea

Emerging Sleep Testing Methods

Transcription:

Sensitive to Sleep

Patients commonly arouse from sleep and experience awake states. PATIENTS are intolerant of the delivered pressure and can have difficulty returning to sleep. To aid the transition back to sleep, patient comfort is critical. Diagram: Typical sleep / wake pattern in a normal elderly individual. Solid white area represents REM sleep; green areas represent arousals and awake states. Source: Respiratory Care: A Guide to Clinical Practice 4 th ed. 1997 Burton et al. Section 11, Aran et al. Sleep-Disordered Breathing, Pg 295-308. S L E E P S T A G E S Awake Arousals stage 1 & REM Stage 2 delta sleep Typical Histogram in a normal elderly individual Time Hours 1 2 3 4 5 6 7 8

The Problem Up to 9% of the adult population are affected by Obstructive Sleep Apnea (OSA) with a trend of increasing prevalence. (1-2) The common treatment for OSA is positive airway pressure therapy. However, patients can be intolerant of the pressure when they arouse from sleep and experience awake states. Pressure is not required during wakefulness and can cause discomfort, making it difficult for patients to return to sleep. As this discomfort may be detrimental to overall therapy compliance, lowering the pressure during awake states can improve comfort and compliance. References: (1) Young et al, Epidemiology of Obstructive Sleep Apnea; A Population Health Perspective. Am J Respir Crit Care Med 2002; 165:1217 1239. (2) Young T, Palta M, Dempsey J, et al. The occurrence of sleep-disordered breathing in among middle-aged adults. N Engl J Med 1993; 328:1230-1235.

A U T O S E R I E S The SleepStyle 200 Auto Series provides pressure on demand and innovative SensAwake Technology to personalize sleep treatment to patients needs. SensAwake Introducing SensAwake SENSAWAKE AMBIENT TRACKING PLUS Unique SensAwake Technology senses the critical awake state of patients and promptly reduces the delivered pressure to the lowest, most comfortable level. Treatment is personalized during sleep and awake states. SensAwake makes returning to sleep easier to increase sleep quality and to ultimately improve therapy uptake. Ambient Tracking Plus technology provides effective humidification under changing Conditions. This humidification technology compensates for changing temperatures and humidity loss during leaks.

The Solution The SleepStyle 200 Auto Series uses unique SensAwake Technology to sense the critical awake state of patients and promptly reduce the delivered pressure to the lowest, most comfortable level. Through the combination of SensAwake and the advanced auto-adjusting system, treatment is personalized during sleep and awake states. This makes returning to sleep easier to increase sleep quality and ultimately improve therapy uptake. senses the changes in breathing between sleep and awake states.

Sensitive to Sleep Irregular respiration has been identified as a marker of wakefulness. Research has shown an automated technique can identify wakefulness. (3) The versatile SleepStyle 200 Auto Series offers titration and long-term treatment solutions for patients. The auto-adjusting algorithm detects and effectively responds to flow limitations, apneas and hypopneas. This enables the SleepStyle 200 Auto Series to automatically adjust its pressure to enable your patients to sleep easier. Reference: (3) Ayappa I, Norman R, Whiting D, et al. Automated detection of irregular respiration: A marker of wakefulness. Sleep Medicine 7 2006; S83.

FIGURE 1: Pattern of regular breathing seen during non-rem sleep in the absence of sleep-disordered breathing. 120 Seconds of flow signal 30 Seconds SLEEP EPOCH Regular respiration corresponds with sleep (non-rem) on the polysomnogram. FIGURE 2: Irregularity of the airflow signal during a transition from sleep to wake. 120 Seconds of flow signal 30 Seconds AWAKE EPOCH Irregularity of the flow signal corresponds with awake epoch on the polysomnogram. References: (4) Norman R, Ayappa I, Whiting D, et al. Irregular respiration as a marker of anxious wakefulness. ATS 2005 International Conference. San Diego, California, USA, 2005; A64. (5) Ayappa I, Norman R, Whiting D, et al. Automated detection of irregular respiration: A marker of wakefulness. Sleep Medicine 7 2006; S83. (6) Vgontzas A and Kales A. Sleep and its disorders. Annual Review of Medicine 1999; 50:387-400. IRREGULAR RESPIRATION AS A MARKER OF WAKEFULNESS: Sleep in the absence of disordered breathing is marked by regular respiration (Fig. 1). Transient ventilatory irregularities often occur at the transition from sleep to awake states (Fig. 2). (4) SensAwake automatically detects these sleep/wake transitions using a sophisticated algorithm. (5) Upon detecting the awake state the pressure is promptly reduced, to alleviate discomfort and facilitate a rapid return to sleep. SensAwake is a technological breakthrough in the delivery of positive airway pressure. The SensAwake algorithm is intuitive (5) and pays particular attention to the withdrawal of pressure in the awake state. SensAwake personalizes therapy to the patient s unique sleep pattern. (6)

Your Patient s Comfort Your Patient s Comfort Personalized Pressure Humidification IT HAS BEEN SHOWN THAT PATIENT COMFORT IS INCREASED WITH THE USE OF Personalized Pressure (7) and HEATED HUMIDIFICATION. (8) Patients receive effective and comfortable treatment due to advanced personalized pressure delivery that adjusts to suit their needs during sleep and awake states. Effective humidification under changing conditions is achieved by Ambient Tracking Plus, minimizing disruptive condensation and maximizing humidity to prevent nasal discomfort. References: (7) Haniffa M, Lasserson TJ, Smith I. Interventions to improve compliance with continuous positive airway pressure for obstructive sleep apnea. Cochrane database of systemic reviews. 2004, Issue 4 Art. No.:CD003531. DOI: 10.1002/14651858.CD003531 pub2. Marrone O, Resta O, Salvaggio A, et al. Preference for fixed or automatic CPAP in patients with obstructive sleep apnea. Sleep Medicine 2004; 5(3):247-251. (8) Massie CA, Hart RW, Peralez K, et al. Effects of humidification on nasal symptoms and compliance in sleep apnea patients using continuous positive airway pressure. Chest 1999; 116:403-408.

Upon waking, comfort is critical to aid the transition back to sleep. The SleepStyle 200 Auto Series is designed for enhanced patient comfort. Patients receive effective and comfortable therapy with personalized pressure delivery and humidification during sleep and awake states. Personalized therapy enhances the quality of sleep and encourages improved patient compliance.

Managing Your Patients All Fisher & Paykel Healthcare products are designed to deliver real benefits for you and your patients. The SleepStyle 200 Auto Series is an advanced auto-adjusting system designed to enhance patient comfort and improve therapy uptake while contributing to the efficiencies of your service(s). It employs a number of innovative features that minimize set-up times and patient follow-up. Analysis of therapy is streamlined by the new patient efficacy reporting software, PerformanceMaximizer. The SmartStick offers easy monitoring of treatment parameters for comprehensive patient management. The table below shows the range of performance features available in the SleepStyle 200 Auto Series: SleepStyle 200 Auto Series Performance Category Performance Feature Pressure Control A Auto-adjusting CPAP B SensAwake Technology C Altitude Adjustment Control Manual D Leak Compensation Humidification Delivery E Fully Integrated System F Ambient Tracking Plus Performance Logging G PerformanceMaximizer Software H SmartStick Removable Media

The SLEEPSTYLE 200 Auto Series Features: Auto-adjusting CPAP Technology: The SleepStyle 200 Auto Series offers pressure on demand with advanced flowbased sensing technology. The auto-adjusting algorithm detects and effectively responds SensAwake: Patients commonly arouse from sleep and experience awake states, during which they are often intolerant of pressure. SensAwake uses flow to monitor patients breathing patterns, identifies these awake states and promptly reduces the pressure. This aids the transition back to sleep in order to enhance acceptance of treatment. Ambient Tracking Plus: This technology provides effective humidification under changing conditions. It minimizes condensation to prevent mask pressure fluctuations and algorithm disruptions while maximizing humidity during leaks to prevent nasal discomfort. Removable Media: The SmartStick, along with PerformanceMaximizer software, allows for easy monitoring of treatment efficacy and comprehensive patient management. 10

For more information, please contact your local Fisher & Paykel Healthcare representative: Fisher & Paykel Healthcare has a policy of continuous product improvement and reserves the right to alter specifications without notice. Patented in principal countries of the world. International PO Box 14 348, Panmure Auckland 1741, New Zealand Tel: +64 9 574 0100 Fax: +64 9 574 0158 Email: info@fphcare.com Web: www.fphcare.com Australia Tel: +61 3 9879 5022 Fax: +61 3 9879 5232 Austria Tel: 0800 29 31 23 Fax: 0800 29 31 22 Benelux Tel: +31 78 644 0924 Fax: +31 78 644 0914 China Tel: +86 20 3205 3486 Fax: +86 20 3205 2132 France Tel: +33 1 64 46 5201 Fax: +33 1 64 46 5221 Germany Tel: +49 7182 93777 0 Fax: +49 7182 93777 99 India Tel: +91 80 4123 6041 Fax: +91 80 4123 6044 Irish Republic Tel: 1800 409 011 Italy Tel: +39 06 7839 2939 Fax: +39 06 7814 7709 Japan Tel: +81 3 3661 7205 Fax: +81 3 3661 7206 Middle East Tel: +9 71 4 360 0849 Fax: +9 71 4 368 8110 Northern Ireland Tel: 0800 132 189 Spain Tel: +34 902 013 346 Fax: +34 902 013 379 Switzerland Tel: 0800 83 47 63 Fax: 0800 83 47 54 UK (EU Authorized Representative) Tel: +44 1628 626 136 Fax: +44 1628 626 146 USA Tel: 1800 446 3908 +1 949 453 4000 Fax: +1 949 453 4001 Fisher & Paykel Healthcare Limited 185044886 RevB