Photon Attenuation Correction in Misregistered Cardiac PET/CT

Similar documents
Identifying Image Artifacts, Their Causes and How to Fix Them: PET. Brad J Kemp, PhD Mayo Clinic, Rochester, MN

Typical PET Image. Elevated uptake of FDG (related to metabolism) Lung cancer example: But where exactly is it located?

For myocardial perfusion SPECT, professional societies recommend

The development of combined PET/CT scanners has

Quantitative outcome of registration methods for correcting cardiac drift in cardiac PET/CT imaging

CARDIAC PET PERFUSION IMAGING with RUBIDIUM-82

A Snapshot on Nuclear Cardiac Imaging

Habib Zaidi Rene Nkoulou Sarah Bond Aylin Baskin Thomas Schindler Osman Ratib Jerome Declerck

Advantages of PET Myocardial Imaging

Validation of CT Perfusion Imaging Against Invasive Angiography and FFR on a 320-MDCT Scanner

2017 Qualified Clinical Data Registry (QCDR) Performance Measures

Accurate attenuation correction (AC) is a major clinical

PET is currently the accepted gold standard in noninvasive

Myocardial perfusion PET at rest and with pharmacologic

Impaired Regional Myocardial Function Detection Using the Standard Inter-Segmental Integration SINE Wave Curve On Magnetic Resonance Imaging

GE Healthcare. Rad Rx. White Paper

MEDVISO WHITE PAPER ON STRAIN ANALYSIS IN TAGGED MR IMAGES

Attenuation correction via transmission maps has long been an integral part of

2019 Qualified Clinical Data Registry (QCDR) Performance Measures

J of Nuclear Medicine Technology, first published online January 24, 2014 as doi: /jnmt

Bone PET/MRI : Diagnostic yield in bone metastases and malignant primitive bone tumors

Dual cardiac respiratory gated PET: implementation and results from a feasibility study

05/02/ CPT Preauthorization Groupings Effective May 2, Computerized Tomography (CT) Abdomen 6. CPT Description SEGR CT01

4D PET: promises and limitations

Preview of Presentation

Measurement of Respiratory and Cardiac Motion Using a Multi Antenna Continuous Wave Radar Operating in the Near Field

Soft-tissue attenuation influences the diagnostic accuracy

Fundamentals of Nuclear Cardiology. Terrence Ruddy, MD, FRCPC, FACC

Feasibility of a New C-arm angiography (DYNA-CT) based three-dimensional algorithm in combination with myocardial perfusion assessment

ASNC CONSENSUS STATEMENT REPORTING OF RADIONUCLIDE MYOCARDIAL PERFUSION IMAGING STUDIES. Approved August 2003

PET for the Evaluation of Myocardial Viability

General Cardiovascular Magnetic Resonance Imaging

Calculation methods in Hermes Medical Solutions dosimetry software

POSITRON EMISSION TOMOGRAPHY (PET)

Typical chest pain with normal ECG

Pitfalls and Remedies in PET/CT imaging for RT planning

María del Pilar Garrido Ruiz Teresa Mendoza Dobaño Cristian Jesús Lucena Morales

PET-MRI in malignant bone tumours. Lars Stegger Department of Nuclear Medicine University Hospital Münster, Germany

Case-Based Pitfalls of SPECT and PET: Recognizing and Working with Artifacts

Biases affecting tumor uptake measurements in FDG-PET

AMERICAN IMAGING MANAGEMENT

AMERICAN IMAGING MANAGEMENT

Cardiac PET. John Buscombe

Perspectives of new imaging techniques for patients with known or suspected coronary artery disease

2016 Qualified Clinical Data Registry (QCDR) Performance Measures

State-of-the-Art SPECT/CT: Cardiac Imaging

NUCLEAR CARDIOLOGY UPDATE

SPECT-CT: Τι πρέπει να γνωρίζει ο Καρδιολόγος

Assessment of cardiac function using myocardial perfusion imaging technique on SPECT with 99m Tc sestamibi

Sung A Chang Department of Internal Medicine, Division of Cardiology, Sungkyunkwan University School of Medicine, Samsung Medical Center

Cigna - Prior Authorization Procedure List: Radiology & Cardiology

Evidence for myocardial CT perfusion imaging in the diagnosis of hemodynamically significant coronary artery disease

BlueAdvantage SM. & BlueChoice SM Radiology Prior Authorization Program Code List CPT /HCPS

Nuclear Cardiology Pierre-Yves MARIE Department of Nuclear Medicine CHU-Nancy, FRANCE.

Cardiology for the Practitioner Advanced Cardiac Imaging: Worth the pretty pictures?

Conflict of Interest Disclosure

The Value of Tc-99m MIBI Washout Rate in Detection of Ischemia compared with standard Myocardial Perfusion Imaging

Patterns and Prevalence of Misregistration in 18 F-FDG PET/CT

Detection of Mild Cognitive Impairment using Image Differences and Clinical Features

Animals. Male C57Bl/6 mice (n=27) were obtained from Charles River (Sulzfeld, Germany) and

Reproducibility of Uptake Estimates in FDG PET: a Monte Carlo study

evicore cardiology procedures and services requiring prior authorization

Rubidium-82 myocardial perfusion PET/CT

Measurement of Ventricular Volumes and Function: A Comparison of Gated PET and Cardiovascular Magnetic Resonance

SPECT or PET for Cardiovascular Screening in High-Risk Patients

Diagnostic Imaging Prior Review Code List 2 nd Quarter 2018

Diagnostic Imaging Utilization Management and Consultation Management Programs Imaging Code Listing for Connecticut, Maine and New Hampshire

Imaging in epilepsy: Ictal perfusion SPECT and SISCOM

Radiation Detection and Measurement

Fellows on this rotation are expected to attend nuclear conferences and multimodality imaging conference.

Is metal artefact reduction mandatory in cardiac PET/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

University of Groningen. Quantitative CT myocardial perfusion Pelgrim, Gert

Positron emission tomography myocardial perfusion and glucose metabolism imaging

Myocardial viability testing. What we knew and what is new

TITLE: Systolic Diastolic Partial Volume Differences on ECG-Gated Rb-82 Cardiac PET for Partial

Cigna - Prior Authorization Procedure List: Radiology & Cardiology

Cardiovascular Imaging

Nuclear Cardiology Cardiac Myocardial Perfusion with 82 Rb. Dominique Delbeke, MD, PhD Vanderbilt University Medical Center Nashville, TN

Promising New Fluorine-18 Labeled Tracers for PET Myocardial Perfusion Imaging

High Tech Imaging Quick Reference Guide

Introduction. Cardiac Imaging Modalities MRI. Overview. MRI (Continued) MRI (Continued) Arnaud Bistoquet 12/19/03

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

Clinical PET/CT imaging. PET/CT - Optimization of torso imaging. CT-based attenuation correction. PET/CT torso imaging

Zahid Rahman Khan, MD(USA), MS Diplomate American Board of Nuclear Medicine Consultant t Nuclear Medicine

Cardiac Imaging. Kimberly Delcour, DO, FACC. Mahi Ashwath, MD, FACC, FASE. Director, Cardiac CT. Director, Cardiac MRI

Pearls & Pitfalls in nuclear cardiology

Myocardial Perfusion: Positron Emission Tomography

CT Perfusion. U. Joseph Schoepf, MD, FAHA, FSCBT MR, FSCCT Professor of Radiology, Medicine, and Pediatrics Director of Cardiovascular Imaging

45 Hr PET Registry Review Course

MPI Overview. Artifacts and Pitfalls in MPI. Acquisition and Processing. Peeyush Bhargava MD, MBA

A Comparison of Strategies for Summing Gated Myocardial Perfusion SPECT: Are False Negatives a Potential Problem?

Precision and accuracy of clinical quantification of myocardial blood flow by dynamic PET: a technical perspective

RADIOTRACERS FOR MYOCARDIAL PERFUSION IMAGING

Myocardial perfusion scintigraphy using rubidium-82 positron emission tomography

Cardiac Nuclear Medicine

TW Hamilton, EP Ficaro, TA Mitchell, JN Kritzman, JR Corbett University of Michigan Health System, Ann Arbor, MI

INNOVATIONS IN SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY

Cardiac Imaging Tests

The Integral Role of Metabolic and Perfusion Imaging in Assessment of Myocardial Scar: Comparison between 18F-FDG PET and 99Tc-Sestamibi

Transcription:

Photon Attenuation Correction in Misregistered Cardiac PET/CT A. Martinez-Möller 1,2, N. Navab 2, M. Schwaiger 1, S. G. Nekolla 1 1 Nuklearmedizinische Klinik der TU München 2 Computer Assisted Medical Procedures and Augmented Reality, TU München Email: a.martinez-moller@lrz.tu-muenchen.de Abstract. PET-CT misalignment has been reported as a source of artefacts in cardiac PET/CT due to a biased photon attenuation correction. Using the data from 28 cardiac PET/CT rest/stress examinations, PET- CT misalignment was corrected using three different methods: manual registration, automatic mutual information based image registration and an emission-driven correction algorithm. The clinical effects of the realignment were quantitatively assessed, and significant changes were observed in 6 out of 28 examinations (21.4%), in 5 of these studies resulting in the disappearance of large apparent perfusion defects. These results indicate that the excellent specificity of PET for the detection of perfusion defects could be compromised when CT-based attenuation correction is done without correction of PET-CT misalignment. 1 Introduction Positron emission tomography (PET) is a functional imaging technique which provides volumetric images of the distribution of a radiotracer in the body. This is achieved through the detection of 511 kev photons produced by the annihilation of positrons emitted by the radiotracer. However, only a fraction of the photons is being detected, as a significant part is being attenuated (either scattered or absorbed) through interactions within the body, according to the following formula: A = A 0 exp µ(x)dx (1) where A 0 is the flow of initial photons, A the flow of photons which go through the trajectory without suffering attenuation, and µ the coefficient of attenuation for each of the body regions within each photon s trajectory. Therefore, a correction for photon attenuation is necessary for accurate quantification of PET images. This is done through the obtention of attenuation maps containing the coefficient µ for each part of the body [1]. Since the introduction of combined PET/CT scanners, the attenuation map is usually computed by a bilinear scaling of X-ray tissue radiodensity as measured using CT [2]. One fundamental assumption of the attenuation correction is the accurate spatial registration of the PET emission data and the attenuation maps. However, even when using combined PET/CT scanners, a potential misregistration

228 Fig. 1. On the top row, fused PET/CT examination without attenuation correction showing a clear misregistration. On the bottom, the same examination after attenuation correction. A notable decrease of activity is observed in the misregistered areas of the myocardium due to a biased attenuation correction can be found between both modalities as a result of non simultaneous acquisition and differences in temporal resolution between PET and CT. Such a misregistration can lead to artefacts in the attenuation corrected PET image, as can be seen in Fig. 1. 2 State of the art and new contribution To our knowledge, no studies have reported on the effects of the misregistration for cardiac PET/CT yet. In contrast, the problem of emission-transmission misalignment in cardiac imaging -due to pharmacological stress, patient breathing or other patient motion- has been previously investigated using PET with rotating sources [3, 4], SPECT [5] and SPECT/CT [6]. This work provides new information regarding frequency and extent of cardiac PET-CT misregistration, evaluates the clinical impact of such a misregistration due to artefacts caused by biased photon attenuation correction, and proposes potential solutions to minimize these artefacts. 3 Methods 28 consecutive patients (20 men and 8 women, age 63±12y) with suspected coronary artery disease (CAD) were enrolled in this study. All patients had been referred for a cardiac PET/CT rest/stress perfusion study to evaluate the functional impact of CAD. Imaging was performed on a Siemens Biograph 16 PET/CT (Siemens Medical Solutions, Erlangen, Germany).

229 Transmission data for the thorax were acquired with a low-dose CT scan (120 kv, 26 ma) performed in shallow breathing. After that, patients received a 300 to 500 MBq injection of 13 N-labelled NH 3 and the PET image was acquired for 10 minutes. Image data from 5 min p.i. to 10 min p.i. was summed and used for further analysis. 3.1 PET-CT registration In order to investigate the clinical effects of PET-CT misalignment we sought to remove the misregistration by realigning the CT to the PET and repeating the PET reconstruction with the aligned CT-based attenuation map. For this purpose, a registration program was developed using IDL (Interactive Data Language, RSI Inc. Boulder, CO, USA), allowing three different possibilities to realign the PET and CT examinations: manual registration (only translational motion allowed), automatic mutual information based registration (exhaustive search within the translational space), and an emission driven correction method to modify the heart outline based on the PET data. The emission driven correction is an in-house developed method based on the following assumption: if there is tracer uptake corresponding to the left ventricle (LV) in the PET image, the corresponding voxel in the CT should contain cardiac tissue. However, in case there is an inconsistency and the voxel contains lung tissue and therefore nearly no attenuation, the value of the voxel is modified to match that of cardiac tissue. As this operation was only to be applied in the LV. a fully automatic segmentation of the LV from the PET scan was required, and performed by means of a spatially localized thresholding, as the LV has always high NH 3 uptake. The segmentation and modification of the attenuation map required less than one second runtime using a standard personal computer. For each PET examination, all three realignment techniques mentioned above were separately applied, and the PET raw data was reconstructed again hsing each of the realigned CT. The tracer uptake was quantified before and after realignment by spatially sampling the left ventricle and projecting the measured activity on a polar map basis. The polar map was then divided in 17 segments according to the AHA17 model [7] and compared to a normal NH 3 perfusion map. Segments where the uptake differed by more than 2.5 standard deviations were considered as perfusion defects. 4 Results The average misalignment between the PET and CT datasets assessed by manual registration was 6.1±6.3 mm. The spatial distribution of the motion was as follows: left-right 1.3±2.2 mm (range: 0-5.1 mm), anterior-posterior 1.6±2.9 mm (range: 0-15.4 mm), head-feet 4.7±6.1 mm (range: 0-23.6 mm). Head-feet motion represented the major component of the misalignment, in agreement with the main direction of the breathing motion. The maximum value of the misalignment for an examination was 29 mm.

230 The defect size as quantified by comparison to a normal database changed by more than 10 %LV in 6 out of 28 patients (21.4%), all of them following a manual realignment greater than 10 mm. In 5 of the 6 patients, the perfusion defect - which ranged between 15 and 46 %LV- was fully artifactual and disappeared after reconstruction with the realigned CT-based attenuation map. Automatic mutual information based image registration was not successful for the registration of PET and CT cardiac images. The effects of a misaligned heart in the were largely compensated by a reasonably well aligned thorax, so that the registration indicated that the original pose was always the best alignment. Subsequently, we tested a more regional approach by applying the registration to a manually defined volume of interest around the heart. Unfortunately, this technique did not produce better results, as the low correlation between the functional information provided by PET and the anatomical detail provided by CT made mutual information fail, being incapable of properly assessing the agreement between both poses when limited to the cardiac region only. The emission-driven method had results equivalent to those obtained by manual registration. The correlation between the variation of measured uptake produced by both methods was high (R 2 = 0.74, p < 0.001) and good agreement was seen for large misregistration-induced defects. 5 Discussion The results in this study indicate that PET-CT misregistration occurs frequently in cardiac perfusion studies and can have important clinical consequences. Changes of the defect size larger than 10% of the myocardium were observed in 6 out of 28 patients (21.4%), fact which which could compromise the otherwise excellent specificity of PET for the detection of perfusion defects. Realignment of CT to PET and repetition of the PET reconstruction minimizes the artefacts induced by a biased photon attenuation correction. Although automatic registration would be the optimal approach, we obtained disappointing results for the cardiac region, indicating that manual registration is the only solid option. Alternatively to manual registration, the proposed emission-driven correction yielded equivalent results, having the advantages of being fast and fully automatic. References 1. Zaidi H, Hasegawa BH. Determination of the attenuation map in emission tomography. J Nucl Med 2003;44:291 315. 2. Kinahan P, Hasegawa BH, Beyer T. X-ray-based attenuation correction for positron emission tomography/computed tomography scanners. Sem Nucl Med 2003;33(3):166 179. 3. Loghin C, Sdringola S, Gould KL. Common artifacts in PET myocardial perfusion images due to attenuation-emission misregistration: Clinical significance, causes and solutions. J Nucl Med 2004;45:1029 1039.

231 4. McCord ME, Bacharach SL, Bonow RO, et al. Misalignment between PET transmission and emission scans: Its effect on myocardial imaging. J Nucl Med 1992;33:1209 1213. 5. Matsunari I, Boning G, Ziegler SI. Effects of misalignment between transmission and emission scans on attenuation-corrected cardiac SPECT. J Nucl Med 1998;39:411 416. 6. Fricke H, Fricke E, Weise R, et al. A method to remove artifacts in attenuationcorrected myocardial perfusion SPECT introduced by misalignment between emission scan and CT-derived attenuation maps. J Nucl Med 2004;45:1619 1625. 7. Cerqueira MD, Weissman NJ, Dilsizian V. Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: A statement for healthcare professionals from the cardiac imaging committee of the council on clinical cardiology of the American Heart Association. Circulation 2002;105:539 542.