Cytoreductive Surgery and Hyperthermic Intraperitoneal Chemotherapy

Similar documents
Useful Ectopics: Case Study. Effects of vasodilation and the diagnostic value of ectopic heartbeats

Where there s flow, there s life. Measuring flow and pressure together, for even greater control

Impedance Cardiography (ICG) Application of ICG for Hypertension Management

Impedance Cardiography (ICG) Application of ICG in Intensive Care and Emergency

Cardiac Output Monitoring - 6

Impedance Cardiography (ICG) Method, Technology and Validity

Topics to be Covered. Cardiac Measurements. Distribution of Blood Volume. Distribution of Pulmonary Ventilation & Blood Flow

SHOCK. Emergency pediatric PICU division Pediatric Department Medical Faculty, University of Sumatera Utara H. Adam Malik Hospital

Hemodynamic Monitoring and Circulatory Assist Devices

The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the PreSep oximetry catheter for

HOW LOW CAN YOU GO? HYPOTENSION AND THE ANESTHETIZED PATIENT.

Posted: 11/27/2011 on Medscape; Published Br J Anaesth. 2011;107(2): Oxford University Press

Introduction. Invasive Hemodynamic Monitoring. Determinants of Cardiovascular Function. Cardiovascular System. Hemodynamic Monitoring

Goal-directed vs Flow-guidedresponsive

The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the PreSep oximetry catheter for

Admission of patient CVICU and hemodynamic monitoring

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE

FloTrac Sensor and Edwards PreSep Central Venous Oximetry Catheter Case Presentations

Titrating Critical Care Medications

Physiologic Based Management of Circulatory Shock Kuwait 2018

CARDIAC OUTPUT Monitoring ANDY CAMPBELL JOURNAL CLUB NOV 2011

Tailored Volume Resuscitation in the Critically Ill is Achievable. Objectives. Clinical Case 2/16/2018

Obligatory joke. The case for why it matters. Sepsis: More is more. Goal-Directed Fluid Resuscitation 6/1/2013

TOPIC : Cardiogenic Shock

Staging Sepsis for the Emergency Department: Physician

Special Lecture 10/28/2012

Department of Intensive Care Medicine UNDERSTANDING CIRCULATORY FAILURE IN SEPSIS

-Cardiogenic: shock state resulting from impairment or failure of myocardium

WE NEED TO REDISCOVER PHYSIOLOGY!

The Use of Dynamic Parameters in Perioperative Fluid Management

The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the Edwards PreSep oximetry catheter

How and why I give IV fluid Disclosures SCA Fluids and public health 4/1/15. Andrew Shaw MB FRCA FCCM FFICM

Disclaimer. Improving MET-based patient care using treatment algorithms. Michael R. Pinsky, MD, Dr hc. Different Environments Demand Different Rules

Nurse Driven Fluid Optimization Using Dynamic Assessments

ADVANCED PATIENT MONITORING DURING ANAESTHESIA: PART ONE

Cardiac Output MCQ. Professor of Cardiovascular Physiology. Cairo University 2007

Cardiovascular Management of Septic Shock

Dr. F Javier Belda Dept. Anesthesiology and Critical Care Hospital Clinico Universitario Valencia (Spain) Pulsion MAB

Edwards FloTrac Sensor & Performance Assessments of the FloTrac Sensor and Vigileo Monitor

Sepsis Wave II Webinar Series. Sepsis Reassessment

BIOL 219 Spring Chapters 14&15 Cardiovascular System

SHOCK AETIOLOGY OF SHOCK (1) Inadequate circulating blood volume ) Loss of Autonomic control of the vasculature (3) Impaired cardiac function

Nothing to Disclose. Severe Pulmonary Hypertension

Standard Operating Procedure (SOP) Management of intervention group patients SOP 001

-12. -Ensherah Mokheemer - ABDULLAH ZREQAT. -Faisal Mohammad. 1 P a g e

WHICH CARDIAC OUTPUT MONITOR IN COLORECTAL ENHANCED RECOVERY? :

Vasoactive Medications. Matthew J. Korobey Pharm.D., BCCCP Critical Care Clinical Specialist Mercy St. Louis

Making the Case For Less Invasive Flow Based Parameters: APCO + SVV. Patricia A. Meehan, RN, MS, CCRN (a) Education Consultant Edwards Lifesciences

SHOCK and the Trauma Victim. JP Pretorius Department of Surgery & SICU Steve Biko Academic Hospital.

Ruminations about the Past, Present, and Future

FUNDAMENTALS OF HEMODYNAMICS, VASOACTIVE DRUGS AND IABP IN THE FAILING HEART

Vital Signs. Vital Signs. Pulse. Temperature. Respiration. Blood Pressure

IV fluid administration in sepsis. Dr David Inwald Consultant in PICU St Mary s Hospital, London CATS, London

Evaluation of Left Ventricular Function and Hypertrophy Gerard P. Aurigemma MD

Assessing Preload Responsiveness Using Arterial Pressure Based Technologies. Patricia A. Meehan, RN, MS Education Consultant Edwards Lifesciences, LLC

Intra-operative Echocardiography: When to Go Back on Pump

Blood pressure. Formation of the blood pressure: Blood pressure. Formation of the blood pressure 5/1/12

Special Lecture 11/08/2013. Hypertension Dr. HN Mayrovitz

Surviving Sepsis Campaign Guidelines 2012 & Update for David E. Tannehill, DO Critical Care Medicine Mercy Hospital St.

Fluid bolus of 20% Albumin in post-cardiac surgical patient: a prospective observational study of effect duration

Printed copies of this document may not be up to date, obtain the most recent version from

3/14/2017. Disclosures. None. Outline. Fluid Management and Hemodynamic Assessment Paul Marik, MD, FCCP, FCCM

MANAGEMENT OF CIRCULATORY FAILURE

PHYSIOLOGY MeQ'S (Morgan) All the following statements related to blood volume are correct except for: 5 A. Blood volume is about 5 litres. B.

Haemodynamics. Milan Chovanec Department of Physiology 2.LF UK

SEPSIS RAPID RESPONSE

Critical Care Nursing Program August to November, 2015 Full-time Lesson A13 Pumping and Perfusion III Basic Hemodynamic Monitoring

Reducing Variation in Perioperative Fluid Utilization Results in Improved Surgical Outcomes

Management of Cardiogenic Shock. Dr Stephen Pettit, Consultant Cardiologist

Prof. Dr. Iman Riad Mohamed Abdel Aal

Relax and Learn At the Farm 2012

FAILURE IN PATIENTS WITH MYOCARDIAL INFARCTION

FLUIDS AND SOLUTIONS IN THE CRITICALLY ILL. Daniel De Backer Department of Intensive Care Erasme University Hospital Brussels, Belgium

The Anatomy and Physiology of the Circulatory System

One monitor for the whole patient pathway

Hemodynamic Monitoring Pressure or Volumes? Antonio Pesenti University of Milan Italy

Swans and Pressors. Vanderbilt Surgery Summer School Ricky Shinall

Swans and Pressors. Vanderbilt Surgery Summer School Ricky Shinall

Sepsis Bundle Project (SEP) Kathy Wonderly RN, MSEd, CPHQ Consultant Developed: April 2015 Most recent Revision: December 2018

Shock, Monitoring Invasive Vs. Non Invasive

Determination of left ventricular stroke volume from the arterial pressure wave

The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the PreSep oximetry catheter for

Intraoperative Fluid Management. David G Hovord BA MB BChir FRCA Clinical Assistant Professor University of Michigan

Early Goal-Directed Therapy

Cardiovascular Effects of Anesthesia for Cesarean Delivery in the Cardiac Patient

haemodynamic monitoring

Technique. Technique. Technique. Monitoring 1. Local anesthetic? Aseptic technique Hyper-extend (if radial)

Chapter 24 Vital Signs. Copyright 2011 Wolters Kluwer Health Lippincott Williams & Wilkins

Sepsis Combine experience and Evidence. Eran Segal, MD Director General ICU, Sheba Medical Center, Israel

Shock Quiz! By Clare Di Bona

Patient Safety Safe Table Webcast: Sepsis (Part III and IV) December 17, 2014

Disclosure Information : No conflict of interest

FLUID RESUSCITATION AND MONITORING IN SEPSIS PROTOCOLIZED VS USUAL CARE DEEPA BANGALORE GOTUR MD, FCCP ASSISTANT PROFESSOR, WEILL CORNELL MEDICAL

Hemodynamic Monitoring in Critically ill Patients in Arthur Simonnet, interne Tuteur : Pr. Raphaël Favory

VASOPRESSORS AND INOTROPES CLINICAL PROFESSOR ANDREW BEZZINA FACEM MAY 2017

Full Disclosure. The case for why it matters. Goal-directed Fluid Resuscitation

The Septic Patient. Dr Arunraj Navaratnarajah. Renal SpR Imperial College NHS Healthcare Trust

Shock and hemodynamic monitorization. Nilüfer Yalındağ Öztürk Marmara University Pendik Research and Training Hospital

HAEMODYNAMIC DYSFUNCTION AFTER ABDOMINAL AORTIC ANEURYSM REPAIR

Taking the shock factor out of shock

Transcription:

Cytoreductive Surgery and Hyperthermic Intraperitoneal Chemotherapy A 44 year old female undergoing 10 hour Cytoreductive (CRS) procedure followed by Hyperthermic Intraperitoneal Chemotherapy (HIPEC). CRS and HIPEC involves a large abdominal incision, extensive peritoneal stripping and highly invasive application of heated chemotherapy to the remaining abdominal contents for an average of 60 minutes. This causes major shifts in blood fluid, blood pressure, coagulation, respiratory, electrolytes and body temperature. Due to the significant dilatation effects of HIPEC these patients lose fluids and are often hypotensive. It is therefore essential to be able to accurately monitor and differentiate between both blood pressure and blood flow. This enables the clinician to confidently manage the multiple interventions required to ensure optimal organ perfusion. ODM+ is uniquely designed to guide both the fluids and vasoactive drugs during this procedure, utilising the combination of technologies available within the device. Oesophageal Doppler directly and accurately measures the blood flow and enables the clinician to intervene using the Doppler-specific 10% stroke volume algorithm for fluids as well as to titrate vasoactive agents and inotropes. The timing, balance, and interaction of both fluids and drugs is critical in these cases. The calibrated pulse pressure algorithm is ideal to provide longer term monitoring and when diathermy interferes with the ultrasound signal. High Definition Impedance CardioGraphy (HD-ICG) can then be used after surgery to ensure the patient is not hyper or hypovolaemic 48 hours post operatively. Screenshot 1 CRS Patient Optimised Blood loss during CRS is minimal so the first objective is to get the patient fluid optimised at the start of surgery, understanding that the up-coming interventions will cause significant shifts in haemodynamics. Most of these patients are young, (<50 years old) and are usually cardiovascularly fit. During both the CRS and especially in HIPEC the patient can be hypotensive (MAP <65) and phenylephrine is typically given. Phenylephrine will increase blood pressure, but due to the nature of this drug it can also significantly decreases cardiac output (CO) and stroke volume (SV), so it is therefore vital to be able to accurately measure and visualise the patient s blood flow before administering this drug. The ODM+ is unique as it provides real time information on the patient s CO and SV as well as information on contractility (PV) and afterload (FTc) which can all change when vasoactive drugs are given. www.deltexmedical.com page 1 of 7

Screenshot 2 Haemodynamics Before Phenylephrine Infusion Managing blood pressure is very important during the procedure and understanding the impact on blood flow is very important. This patient became hypotensive (MAP <60) so phenylephrine was administered. The screenshot above shows the CO and SV before the infusion was started. www.deltexmedical.com page 2 of 7

Screenshot 3 Haemodynamics After Phenylephrine Infusion The screenshot above was taken 8 minutes after phenylephrine infusion was started MAP and HR increases to try to maintain CO, but SV and PV has reduced by 20%. This is where it is critical to utilise the ODM+ which accurately identifies this reduction, compared to technologies that use blood pressure waveform analysis alone, that will show SV increasing at this point. Blood pressure-derived algorithms incorrectly assume a rise in blood pressure means a rise in SV. www.deltexmedical.com page 3 of 7

There is a lot of diathermy during CRS so the clinician also used the arterial line and the ODM calibrated pulse pressure waveform analysis (PPWA) on the ODM+ to monitor the patient. When interventions are required the screen can be switched back to the Doppler flow based parameters. Screenshot 4 - Pressure Monitoring Mode - End of CRS This screenshot was taken at the end of CRS procedure and the patient has been maintained at the same optimised level, using ODM+ to manage both the fluid boluses and vasoactive drugs as appropriate. Screenshot 5 - Pressure Monitoring Mode - End of CRS At the start of HIPEC the fluid was pumped into the abdominal cavity using the Sun Chip HIPEC system, which caused an increase in intra-abdominal pressure and impairment of venous return. It is very important at this stage to have insight into the actual components of SV such as Flow Time corrected (FTc) and Peak Velocity (PV). www.deltexmedical.com page 4 of 7

Screenshot 6 HIPEC Begins The screenshot below shows the reduction in SV, CO, PV and FTc caused by 3 litres of saline being pumped into the abdominal cavity impacting venous return. During HIPEC there are major shifts in haemodynamics caused by blood loss, blood pressure changes, the depth of anaesthesia and levels of pain control. However, the biggest impact is the introduction of the hyperthermia solution at temperatures of 39-42 C which induces a hypermetabolic state and significant peripheral vasodilation, which is reflected in FTc. www.deltexmedical.com page 5 of 7

Screenshot 7 shows before and after a rapid 250 ml fluid challenge. At 16.39 the patient s SV had dropped to 75 and 7 minutes after the fluid bolus was given the SV increased back to 93. Screenshot 7 Before and After a Fluid Challenge www.deltexmedical.com page 6 of 7

Summary Clinical studies recommend that a liberal approach to fluid management is the best approach during CRS and HIPEC. However, with major shifts in both blood flow and blood pressure this procedure should not be done without using advanced haemodynamic monitoring to accurately manage the timing and response. Fluid loading blindly, towards the end of CRS and at the start of HIPEC, will have a negative impact on the patient s long-term recovery. Using technologies that rely solely on the analysis of blood pressure to derive a blood flow estimate could also be dangerous in these patients. They can give false readings when blood pressure is increasing either when, vasoactive drugs are given, or due to intra-abdominal pressure from the hyperthermic fluid reducing venous return. For example, if at the beginning of HIPEC the pressure-based monitors are recording increases in SV and CO in line with increased blood pressure, it is possible that no more fluid will be administered. The patient could be hypovolaemic, due to the losses caused by peripheral dilatation and increasing systemic oxygen demand. The CardioQ-ODM+ is the only device that measures flow, pressure and impedance. Therefore it can be utilised to ensure the patient is normovolaemic throughout. As such the patient receives neither too much nor too little fluid during this very challenging procedure. Appendix Abbreviations: CO - cardiac output SV - stroke volume FTc - flow time corrected CI - cardiac index SI - stroke index PV - peak velocity HR - heart rate BP - blood pressure CVP - central venous pressure BMI - body mass index area BSA - body surface area Doppler parameter details: FTc - duration of flow during systole and is inversely affected by afterload. Normal range in a resting healthy individual approximately 330-360ms. If afterload is increasing, FTc is likely to reduce and vice versa. Most common cause of a low FTc is hypovolemia - a low circulating blood volume causes vasoconstriction and subsequent reduced FTc. A high FTc is seen in low resistance/afterload states such as sepsis or anaesthesia. PV - can be a good indicator of contractility but is affected by load and age. The shape of the waveform can indicate left ventricular function - more upright waveforms usually indicate good ventricular function whereas a flatter waveform usually indicates reduced ventricular function. www.deltexmedical.com page 7 of 7