Estimation of Glomerular Filtration Rates After Orthotopic Liver Transplantation: Evaluation of Cystatin C Based Equations

Similar documents
Cystatin C-based calculation of glomerular filtration rate in kidney transplant recipients

Can modifications of the MDRD formula improve the estimation of glomerular filtration rate in renal allograft recipients?

A New Approach for Evaluating Renal Function and Its Practical Application

Calculation of glomerular filtration rate based on Cystatin C in cirrhotic patients

Calculation of glomerular filtration rate based on Cystatin C in cirrhotic patients

The inaccuracy of cystatin C and creatinine-based equations in predicting GFR in orthotopic liver transplant recipients

From the 1 Department of Transplantation, Mayo Clinic, Jacksonville, FL; 2 Baylor Regional Transplant Institute, Dallas, TX; 3 Division of

Validation of El-Minia Equation for Estimation of Glomerular Filtration Rate in Different Stages of Chronic Kidney Disease

Cystatin C-based Formula is Superior to MDRD, Cockcroft-Gault and Nankivell Formulae in Estimating the Glomerular Filtration Rate in Renal Allografts

Cystatin C is a reliable marker for estimation of GFR in renal. Transplantation: validation of a new turbidimetric assay using

Comparison of Serum Cystatin C and Creatinine Levels to Evaluate Early Renal Function after Kidney Transplantation

Original Article. Saudi Journal of Kidney Diseases and Transplantation

Is the new Mayo Clinic Quadratic (MCQ) equation useful for the estimation of glomerular filtration rate in type 2 diabetic patients?

Estimating GFR using serum beta trace protein: accuracy and validation in kidney transplant and pediatric populations

ORIGINAL ARTICLE Estimating the glomerular filtration rate using serum cystatin C levels in patients with spinal cord injuries

Antiviral Therapy 13:

Εκηίμηζη ηης μεθρικής λειηοσργίας Ε. Μωραλίδης

GLOMERULAR FILTRATION RATE IN LIVER CIRRHOSIS

Glomerular filtration rate estimated by cystatin C among different clinical presentations

Assessment of glomerular filtration rate in healthy subjects and normoalbuminuric diabetic patients: validity of a new (MDRD) prediction equation

Clinical Usefulness of Serum Cystatin C as a Marker of Renal Function

The estimation of kidney function with different formulas in overall population

International Journal of Pharma and Bio Sciences IS CYSTATIN C ESTIMATION A BETTER MARKER IN CHRONIC KIDNEY DISEASE PATIENTS?

Creatinine- vs. cystatin C-based equations compared with 99m TcDTPA scintigraphy to assess glomerular filtration rate in chronic kidney disease

Evaluation of the Cockroft Gault, Jelliffe and Wright formulae in estimating renal function in elderly cancer patients

GFR prediction using the MDRD and Cockcroft and Gault equations in patients with end-stage renal disease

Comparison between a serum creatinineand a cystatin C-based glomerular filtration rate equation in patients receiving amphotericin B

9. GFR - WHERE ARE WE NOW?

Glomerular Filtration Rate. Hui Li, PhD, FCACB, DABCC

Cystatin C and renal function in pediatric renal transplant recipients

Evaluation of Renal Profile in Liver Cirrhosis Patients: A Clinical Study

Glomerular filtration rate estimation in patients with type 2 diabetes: creatinine- or cystatin C-based equations?

A Comparison Of Diagnostic Accuracy Of Cystatin C With Creatinine In The Sample Of Patient Of T2 DM With Diabetic Nephropathy

Bangladesh Journal of Medical Science Vol. 16 No. 02 April 17

Serum and urinary markers of early impairment of GFR in chronic kidney disease patients: diagnostic accuracy of urinary -trace protein

Prediction of two-sample 99m Tc-diethylene triamine pentaacetic acid plasma clearance from single-sample method

Cirrhosis was reported to be the twelfth leading

Measurement and Estimation of renal function. Professeur Pierre Delanaye Université de Liège CHU Sart Tilman BELGIQUE

Comparison of Estimated Glomerular Filtration Rate Using Different Analytes in Chronic Kidney Disease Patients

Correlation of plasma concentrations of cystatin C and creatinine to inulin clearance in a pediatric population

Improved estimation of glomerular filtration rate (GFR) by comparison of egfr cystatin C. and egfr creatinine

Estimates of glomerular filtration rate (GFR) from serum

Cystatin C A Paradigm of Evidence Based Laboratory Medicine

Cystatin C: A New Approach to Improve Medication Dosing

Improved GFR estimation by combined creatinine and cystatin C measurements

PLEASE SCROLL DOWN FOR ARTICLE

Seung Hyeok Han, MD, PhD Department of Internal Medicine Yonsei University College of Medicine

Screening for chronic kidney disease racial implications. Not everybody that pees has healthy kidneys!

Environmental Variability

Am J Nephrol 2013;38: DOI: /

Citation: Sorkhi H, Raheleh Behzadi, Joghtaei N, et al. Glomerular filtration rate determination by

Validity of the use of Schwartz formula against creatinine clearance in the assessment of renal functions in children

Early risk stratification is essential in the management of

Acute renal failure Definition and detection

Objectives. Pre-dialysis CKD: The Problem. Pre-dialysis CKD: The Problem. Objectives

Serum cystatin C is not a better marker of creatinine or digoxin clearance than serum creatinine

Characteristics of factor x so that its clearance = GFR. Such factors that meet these criteria. Renal Tests. Renal Tests

Are prediction equations for glomerular filtration rate useful for the long-term monitoring of type 2 diabetic patients?

Renal function vs chemotherapy dosing

Serum Cystatin C Levels in Children with Nephrosis or Diabetes: A Pilot Study

Comparison between creatinine and cystatin C-based GFR equations in renal transplantation

Measurement and Estimation of renal function. Professeur Pierre Delanaye Université de Liège CHU Sart Tilman BELGIQUE

GFR Estimation in Adolescents and Young Adults

Predictive performance of the modification of diet in renal disease and Cockcroft-Gault equations for estimating renal function.

Correspondence should be addressed to Maisarah Jalalonmuhali;

CYSTATIN C. An Improved Way To Screen For Chronic Kidney Disease INNOVATIONS IN CLINICAL DIAGNOSTICS

Serum Cystatin C as a Predictor of Acute Kidney Transplant Rejection

Comparison between creatinine and cystatin C-based GFR equations in renal transplantation

Special Challenges and Co-Morbidities

Received 30 September 2004; accepted 26 April 2005 Available online 5 August 2005

Comparison of Three Whole Blood Creatinine Methods for Estimation of Glomerular Filtration Rate Before Radiographic Contrast Administration

Supplementary Online Content

British Columbia is the first

Glomerular Filtration Rate Estimations and Measurements. Pierre Delanaye, MD, PhD University of Liège CHU Sart Tilman BELGIUM

Cystatin C is not a better estimator of GFR than plasma creatinine in the general population

מסקנות מיישום סטנדרטיזציה של בדיקת קראטינין : שימוש בנוסחאות לחישוב egfr

T. Gerhardt 1 *, B. Terjung 1 *, P. Knipper 2, H. Palmedo 3, R. P. Woitas 1, J. Kalff 2, T. Sauerbruch 1, U. Spengler 1

Evaluation of the 1B Equation to Estimate Glomerular Filtration Rate in Pediatric Patients with Cancer

An analysis of tacrolimus-related complications in the first 30 days after liver transplantation

The impact of albuminuria and cardiovascular risk factors on renal function Verhave, Jacoba Catharijne

Cystatin C (serum, plasma, urine)

GFR and Drug Dosage Adaptation: Are We still in the Mist?

Comparing cystatin C and creatinine in the diagnosis of pediatric acute renal allograft dysfunction

Evaluation of renal function in intensive care: plasma cystatin C vs. creatinine and derived glomerular filtration rate estimates

Recently, the National Kidney Foundation endorsed a

GFR-estimating models in kidney transplant recipients on a steroid-free regimen

Page 1. Disclosures. Main Points of My Talk. Enlightened Views of Serum Creatinine, egfr, Measured GFR, and the Concept of Clearance

Hyperfiltration Affects Accuracy of Creatinine egfr Measurement

Chronic Kidney Disease Prevalence and Rate of Diagnosis

CKD EVIDENCE TABLES - ALL CHAPTERS

Serum BTP concentrations are not affected by hepatic dysfunction

Epidemiology of Chronic Kidney Disease in Renal Transplantation

Diagnostic value of cystatin C for predicting acute kidney injury in patients with liver cirrhosis

Is There a Chronic Kidney Disease Epidemic? Profile of Chronic Kidney Disease in an Urban Renal Camp in Southern India

Assessing Renal Function: What you Didn t Know You Didn t Know

Nephrology Unit, Department of Medicine, Universiti Kebangsaan Malaysia Medical Center, Cheras, MALAYSIA. 3

AUTOMATIC REPORTING OF CREATININE-BASED ESTIMATED GLOMERULAR FILTRATION RATE IN CHILDREN: IS THIS FEASIBLE?

Introduction to Clinical Diagnosis Nephrology

CYSTATIN-C AND CREATININE BASED FORMULAE FOR ESTIMATION OF GLOMERULAR FILTRATION RATE IN RENAL ALLOGRAFT RECIPIENTS

Transcription:

LIVER TRANSPLANTATION 12:1667-1672, 2006 ORIGINAL ARTICLE Estimation of Glomerular Filtration Rates After Orthotopic Liver Transplantation: Evaluation of Cystatin C Based Equations Thomas Gerhardt, 1 Uwe Pöge, 1 Birgit Stoffel-Wagner, 2 Manuela Ahrendt, 1 Martin Wolff, 3 Ulrich Spengler, 1 Holger Palmedo, 4 Tilman Sauerbruch, 1 and Rainer P. Woitas 1 Departments of 1 Internal Medicine I, 2 Clinical Biochemistry, 3 Surgery, and 4 Nuclear Medicine, University of Bonn, Bonn, Germany Early detection of renal dysfunction in patients after orthotopic liver transplantation is important. Creatinine-based equations to estimate glomerular filtration rate (GFR) were found to be less accurate in liver transplant recipients than in their original populations. Since cystatin C (CysC) is independent from muscle mass and hepatic biosynthesis, we evaluated the diagnostic accuracy of 3 CysC-based equations (Larson, Hoek, and Filler formulae) that are based on the same CysC method as that of our center in comparison to the abbreviated creatinine-based modification of diet in renal disease (MDRD) formula in 59 liver transplant recipients. True GFR was measured by 99mTc-diethylene triamine pentaacetic acid ( 99m Tc-DTPA) clearance. Neither correlation with the GFR (correlation coefficients: 0.594-0.640) nor precision (root mean square error: 15.7-18.17 ml/min/1.73 m 2 ) differed significantly between the tested formulae. The biases of the Hoek and Larsson formulae were significantly smaller than those of the MDRD and Filler equations ( 0.1 and 2.3 vs. 10.1 and 7.9 ml/min/1.73 m 2, respectively; P 0.0023). Mean estimates of MDRD (61.9 21.4 ml/min/1.73 m 2 ) and Filler (61.2 22.1 ml/min/1.73 m 2 ) differed significantly from the measured GFR (52.3 17.5 ml/min/1.73 m 2 ; P 0.005), whereas Larsson and Hoek did not (49.5 20.2 and 51.4 17.9 ml/min/1.73 m 2, respectively). Accuracy within 30% and 50% of the true GFR was best for the Hoek (76.3% and 93.2%) formula, albeit not significantly different from MDRD (64.4% and 83.1%). Taken together, these data show the best overall performance for GFR estimates derived from the Hoek equation with respect to bias, precision, and accuracy. Liver Transpl 12:1667-1672, 2006. 2006 AASLD. Received April 3, 2006; accepted May 26, 2006. Renal dysfunction is a common problem in patients after orthotopic liver transplantation (OLT). Early detection of impaired renal function is crucial to prevent end-stage renal disease (ESRD), which occurs in up to 10% of patients. 1 Limitations of the diagnostic use of creatinine in patients with impaired liver function are well known. 2 Since gold standard methods precisely measuring the glomerular filtration rate (GFR), such as inulin- or validated-isotope clearances, are costly and time consuming, determination of GFR remains difficult in patients with liver diseases. Several creatininebased equations including biochemical, demographic, and anthropometric data have been extensively evaluated in liver transplant recipients. Gonwa and coworkers showed these equations to be applicable, despite poorer performance in comparison to the original population. 3,4 In cirrhotic patients 5 and liver transplant recipients, 6-8 cystatin C (CysC) has been applied as an alternative endogenous serum marker of GFR. Recently, CysC-based formulae were proposed to calculate GFR in patients with various kidney diseases. 9-11 In this study we evaluated the diagnostic performance of 3 CysC-based formulae for GFR estimation in liver transplant recipients. The chosen equations of Abbreviations: OLT, orthotopic liver transplantation; ESRD, end-state renal disease; GFR, glomerular filtration rate; CysC, cystatin C; CV, coefficient of variation; 99m Tc-DTPA, 99mTc-diethylene triamine pentaacetic acid; MDRD, modification of diet in renal disease; RMSE, root mean square error; CI, confidence interval. Presented in part at the annual meeting of the American Society of Nephrology, November 8 13, 2005, Philadelphia, PA. Address reprint requests to Dr. Thomas Gerhardt, Department of Internal Medicine I, University of Bonn, Sigmund-Freud-Str. 25, D-53105 Bonn, Germany. Telephone: 49-228-287-5507; FAX: 49-228-287-9165; E-mail: thomas.gerhardt@ukb.uni-bonn.de DOI 10.1002/lt.20881 Published online in Wiley InterScience (www.interscience.wiley.com). 2006 American Association for the Study of Liver Diseases.

1668 GERHARDT ET AL. Filler, Larsson, and Hoek were derived from cohorts in whom the nephelometric assay (Particle-enhanced nephelometric immunoassay [PENIA], Dade Behring, Marburg, Germany) was used, the same one employed at our center. More recently Grubb and Sjöström published alternative CysC-based equations to calculate GFR. 12-14 As these equations were derived from turbidimetric determinations of CysC (Particle-enhanced turbidimetric immunoassay [PETIA], Dako Cytomation, Glostrup, Denmark) they were not included in our analysis, as divergent results may be due to assay characteristics. PATIENTS AND METHODS Patients Enrolled in the study were 59 consecutive liver transplant recipients (24 female, 35 male) with a mean age of 47.6 12.0 ( SD) years. The mean time after liver transplantation was 5.1 3.0 years. Indications for OLT were as follows: viral hepatitis C (n 10), viral hepatitis B (n 12), viral hepatitis B/D (n 3), hepatocellular carcinoma (n 3), alcoholic liver disease (n 9), autoimmune hepatitis (n 3), primary biliary cirrhosis (n 2), primary sclerosing cholangitis (n 5), veno-occlusive disease (n 1), Wilson s disease (n 2), Alagille syndrome (n 1), amyloidosis (n 1), cystic liver disease (n 1), Senior-Loken syndrome (n 1), amanita phalloides intoxication (n 1), ecstasy intoxication (n 1), and fulminant liver failure of unknown origin (n 3). Immunosuppression was cyclosporine-based in 26 patients and tacrolimus-based in 33 patients. Additionally, 15 patients received prednisone and 4 patients received mycophenolate mofetil. Informed consent was achieved following the institutional guidelines as approved by the local Ethics Committee. Parameters, Assays, and Formulae Serum creatinine was measured with a modified Jaffé method using the Dimension Clinical Chemistry System (Dade Behring). The sensitivity of the creatinine method was 4 mol/l. This sensitivity is defined as the concentration of 2 standard deviations above the CHEM I calibrator (Dade Behring) at 0 mmol/l creatinine (n 20). The intra-assay coefficient of variation (CV) was 0.01 (mean, 61 mol/l; n 20), while the interassay CV was 0.025 (mean, 79.4 mol/l; n 20). Serum CysC was analyzed by fully automated, latexenhanced immunonephelometry (N latex cystatin C on a Nephelometer II; Dade Behring). The 95% reference interval for CysC established from a representative cohort of 100 female and 100 male healthy blood donors (median age, 31 years; 2.5-97.5 percentiles, 19.0-60.5 years) was 0.475-0.820 mg/l. The sensitivity of the assay was 0.05 mg/l. The intra-assay CV for CysC was 1.9% (mean, 0.6 mg/l; n 20), and the interassay CV was 3.6% (mean, 0.6 mg/l; n 20). ( 99m Tc-DTPA) clearance was performed as single-injection technique with 2-point blood sampling according to the method of Russell et al. 15 GFR was estimated using the following equations: GFR 4.32 80.35 1/CysC (Hoek formula 10 ); log(gfr) 1.962 [1.123 log(1/cysc)] (Filler formula 9 ); GFR 77.239 CysC 1,2623 (Larsson formula 11 ); and (MDRD) 186 [serum creatinine (mg/dl)] 1.154 [age 0.203 [0.742 if patient is female] [1.21 if patient is African American]. 16 STATISTICS All results are given as mean SD unless indicated otherwise. Correlations between 99m Tc-DTPA clearance and estimates of GFR were calculated by linear regression analysis (Pearson s correlation). Bias was calculated by the median difference between the true GFR ( 99m Tc-DTPA clearance, serving as gold standard) and the estimated equation-based GFR. Pair-wise comparison of biases was performed using paired t test. Precision of the estimates was expressed in terms of the root mean square error as described elsewhere (root mean square error (RMSE); standard deviation of the mean difference between real GFR and estimated GFR). 17 The F test was used to compare different RM- SEs. The proportion of GFR estimates within 30% and 50% deviation of the true GFR served as a measure of accuracy. 18 McNemar s test was used to compare the proportion of estimates within the 30% and 50% deviation. Analysis was performed using StatView (ver. 5.0 for Windows; SAS Institute, Inc., Cary, NC). Bland and Altman analysis of the GFR estimates and the true GFR was performed with Medcalc (Medcalc Software, Mariakerke, Belgium). 19 P values below 0.05 were considered significant. RESULTS The mean serum level of creatinine and CysC at the time of evaluation was 1.3 0.4 mg/dl and 1.6 0.5 mg/l, respectively (Fig. 1A). In 53 patients (89.8%), measured CysC levels were above the upper reference interval, whereas creatinine was elevated beyond the normal range in only 20 patients (33.9%; P 0.01). The mean GFR ( 99m Tc-DTPA clearance) was 52.3 17.5 ml/min/1.73 m 2. All formula-derived GFR estimates correlated significantly with the GFR, but correlation coefficients did not differ significantly between each other (Table 1). GFR distribution of the individual patients is shown in Figure 1B. The MDRD (61.9 21.6 ml/min/1.73 m 2 ) and Filler (61.2 22.1/1.73m 2 ) estimates differed significantly from the true GFR (52.3 17.5 ml/min/ 1.73 m 2 ; P 0.005), whereas Larsson and Hoek (49.5 20.2 and 51.4 17.9 ml/min/1.73 m 2, respectively) estimates did not. The diagnostic precision measured as RMSE indicates a lower level of precision with higher RMSE values. Although the Hoek equation showed the highest

CYSTATIN C BASED GFR ESTIMATION IN OLT 1669 Figure 1. (A) Distribution of creatinine (mg/dl) and CysC (mg/l) serum levels. Each square and triangle represents the data of a single patient. Crea, creatinine. (B) Distribution of GFR measured by 99m Tc-DTPA clearance in comparison to MDRD- and CysC-based estimates. Each square, dot, and triangle represents the data of a single patient. TABLE 1. Correlation, Difference, Accuracy and Precision of GFR Estimates Correlation Median Difference Median RMSE Accuracy Within Coefficient r 2 * P Value (ml/min/1.73 m 2 ) Difference (%) (ml/min/1.73 m 2 ) 30% 50% MDRD 0.640 0.410 0.0001 10.1 19.6 16.9 64.4 83.1 Filler 0.601 0.360 0.0001 7.9 18.4 18.2 57.6 78.0 Larsson 0.594 0.352 0.0001 2.3 5.1 17.1 69.5 89.8 Hoek 0.606 0.367 0.0001 0.1 0.2 15.7 76.3 93.2 *Square of correlation coefficient as a value of variability of predicted GFR account for variability of measured GFR; P value for correlation is not zero. precision, there was no significant statistical difference between the various equations (Table 1). A small negative bias was found for the Hoek and the Larsson formula ( 0.1 and 2.3 ml/min/1.73 m 2,respectively), whereas a significant overestimation of the true GFR was observed in the MDRD and the Filler equation (10.1 and 7.9 ml/min/1.73 m 2, respectively). The bias of the Hoek and Larsson formulae differed significantly from that of the MDRD and Filler equations (P 0.0023). As recommended by the National Kidney Foundation, we calculated the proportion of the GFR estimates within 30% and 50% of the true GFR as a measure of accuracy. The results given in Table 1 show the highest proportion of estimates within both 30% and 50% of the measured GFR for the Hoek formula (76.3% and 93.2%, respectively). Differences between all tested equations regarding the performance within the 30% and 50% proportion of true GFR were significant (P 0.05) only for comparison between the 50% proportions of the Hoek and the Filler equations. Bland and Altman plots, a graphical method to demonstrate the magnitude and consistency of the differences between calculated and measured values, are presented in Figure 2 A-D. This graphical technique demonstrates the span between 1.96 SD and 1.96 SD of the mean difference between the calculated and the true GFR. The limits of agreement estimated for the Hoek equation are 30 ml/min/1.73 m 2 below or 32 ml/min/1.73 m 2 above the true GFR. Similarly, the Larsson equation shows a span between 37 and 31 ml/min/1.73 m 2. The limits of agreement for the Filler and the MDRD equation are 27 and 45 ml/min/1.73 m 2 and 24 and 43 ml/min/1.73 m 2, respectively. Comparing the range between the limits of agreement, these data show a considerably higher distance between both limits for the MDRD, Larsson and Filler estimates compared to the Hoek formula estimates (66.7, 67.8, and 71.8 ml/ min/1.73 m 2, respectively, vs. 62.1 ml/min/1.73 m 2 ). Similar to the Bland and Altman plot, the widest overlap with the 95% confidence interval (CI) of the true GFR (95% CI: 47.6; 56.9 ml/min/1.73 m 2 ) was seen for the Hoek formula (95% CI: 46.7; 56.1 ml/min/ 1.73 m 2 ), followed by the Larsson equation (95% CI: 44.2; 54.8 ml/min/1.73 m 2 ), whereas only a poor overlap of CIs was seen with the MDRD equation (95% CI: 56.3; 67.6 ml/min/1.73 m 2 ) and the formula of Filler (95% CI: 55.3; 66.9 ml/min/1.73 m 2 ). DISCUSSION In this cross-sectional study, we evaluated the creatinine-based MDRD formula and 3 CysC-based equations for estimation of GFR in liver transplant recipients. We demonstrate that the best overall performance for GFR estimates can be derived from the Hoek equation with respect to bias, precision, and accuracy. However, while CysC-based Hoek and Larsson equations are significantly better than the MDRD formula with

1670 GERHARDT ET AL. Figure 2. Bland and Altman plots presenting (A) MDRD, (B) Larsson, (C) Hoek, and (D) Filler estimates. The Bland and Altman plots demonstrate the magnitude and consistency of the differences between calculated and measured values. The horizontal lines indicate the mean reflecting the mean difference and the span between 1.96 SD and 1.96 SD of the mean difference between the calculated and the true GFR. respect to bias, precision and accuracy did not differ significantly. In clinical practice, GFR is difficult to measure, and most clinicians estimate GFR from serum creatinine concentration, which has been shown to be a poor marker of GFR in patients with liver diseases. 2,20 Several creatinine-based formulae including demographic and anthropometrical parameters have been developed to estimate GFR more precisely. 4,21,22 These equations have been evaluated in a large cohort of liver transplant recipients identifying the MDRD equations as being more precise than the Cockroft-Gault and the Nankivell formulae. 3 However, the precision of the MDRD formula was much lower in the OLT cohort than in the original population. 4 In liver transplant recipients, reduced muscle mass and impaired hepatic biosynthesis can contribute to false low serum creatinine levels. CysC, a cysteine protease inhibitor generated by nucleated cells, freely filtered, reabsorbed, and catabolized in the proximal tubule of the kidney, is independent from muscle mass. 23,24 Consequently, in this study we employed CysC-based formulae in comparison to the abbreviated MDRD equation to estimate GFR in a cohort of patients after OLT. The latter formula was chosen for its simplicity, its dependence on only 1 laboratory variable, and its widespread use in daily clinical practice. In our study, the abbreviated MDRD formula overestimates true GFR. This is in agreement with recent observations in a cohort of renal transplant recipients 25 but is contradictory to the findings of Gonwa, who showed an underestimation of GFR in liver transplant recipients 1 and 5 years after transplantation. Previously, the impact of the calibration of the serum creatinine assay on creatinine-based GFR estimates has been emphasized. 26 As noncreatinine chromogens are known to be detected by the Jaffé method, we used a kinetic modification of the Jaffé method counteracting this possible influence. 27,28 However, this modification cannot replace a calibration of the creatinine method to that used in the original MDRD laboratory. Thus, in contrast to the original MDRD study, our results may lead to lower creatinine values and consequently to a higher estimated GFR, thereupon leading to the considerable positive bias of the MDRD formula. By contrast, the Hoek and Larsson formulae underestimated real GFR. Low-dose corticosteroid medication, which has been supposed to increase CysC serum levels 29 and consequently lead to a lower estimate in the applied formulae, was administered only in a minority of patients of our cohort (n 15; 25%). Indeed, mean CysC serum levels in patients treated with corticosteroids were somewhat higher than in patients on a steroid-free regimen, whereas this difference lacked statistical significance (1.84 0.2 vs. 1.53 0.1 mg/l; P 0.07; data not shown). Filler formula estimates, however, overestimated the true GFR considerably, despite the fact that the gold standard clearance used in the original publication was similar to our study using a single injection technique and a multiple point blood sampling method. 9 Discrepancies may be due to different patient characteristics, as the original cohort consisted of children aged 1-18

CYSTATIN C BASED GFR ESTIMATION IN OLT 1671 years showing hyperfiltration with a mean GFR above 100 ml/min/1.73 m 2, which is roughly twice as high as that in our study. Both CysC-based formulae derived from adult populations (Hoek and Larsson) provided a significantly lower bias and tended to have a higher accuracy than the abbreviated MDRD study equation. In terms of precision, only the Hoek formula tended to be superior to the MDRD formula, albeit without statistical significance. In contrast, recently a comparison between creatinine and CysC-based equations to estimate GFR in renal transplant recipients found the formula suggested by Filler to perform best in comparison with the formulae of Hoek and Larsson. 30 Despite the fact that White and coworkers used the same gold standard as we did and the mean GFR (58 23 ml/min/ 1.73 m 2 ) was comparable, varieties between kidney and liver transplant recipients and differences in steroid dosing between both studies (25% vs. 98% of patients) may account for the observed differences. 30 Studies investigating the diagnostic accuracy of CysC and creatinine as serum markers of renal function in patients after OLT by receiver operating characteristic analyses showed significant advantages for CysC in populations with high average GFR 7,8 but failed to show superiority in cohorts with low mean GFR. 6 We may therefore speculate that CysC-based formulae discriminate better in mildly impaired than in more severely impaired GFR. Thus, these CysC-based estimates may perform better in pediatric patients and patients in the early posttransplantation period than in adult longterm transplant recipients, whose renal function is diminished by, for example, accumulated calcineurin inhibitor toxicity. 3,31 However, the latter population reflects all-day practice in the outpatient department of posttransplant care. There are limitations of our study with regard to our cohort and the methodology. Compared to Gonwa and coworkers, we studied a small number of patients. 3 The superior trend in accuracy of the Hoek and Larsson formulae in comparison to the MDRD equation might become significant in a larger patient cohort. Furthermore, the comparability of our results with data from previous studies may be limited because we studied only Caucasian patients. A multiple point blood sampling may be the best approach to measure GFR by 99m Tc-DTPA. However, several studies confirmed the accuracy of the 2-point sampling plasma method by Russel, which thus may be appropriate in an all-day clinical setting. 32,33 Moreover, as discussed before, the external validation of our study may be limited by the use of a creatinine assay that was not calibrated to the MDRD laboratory. It should be taken into account that in general, results and performances of prediction equations derived from different studies are highly affected by lack of creatinine calibration to one another and different gold-standard GFR methods. Finally, the MDRD 6 equation may improve the performance of the 4 variable MDRD used in our study by adding blood urea nitrogen and albumin into the model. Unfortunately, albumin was not measured in our patients. However, Gonwa and coworkers evaluated both MDRD equations in their large cohort of liver transplant recipients at different time points and found no significant differences between the performance of MDRD 4 and MDRD 6. 3 Taken together, in our cohort of liver transplant recipients the CysC-based Hoek and Larsson estimates of GFR showed better bias when compared to the MDRD formula but lack significant superiority regarding diagnostic accuracy and precision. Since the overall performance of these equations is at least as good or even better than that of the MDRD formula, they represent a reliable tool in the surveillance of renal function in patients after OLT. However, both the currently tested CysC-based GFR estimations and the MDRD are still unsatisfying in these patients, indicating the need to develop appropriate, disease-specific alternatives to overcome these limitations. REFERENCES 1. Gonwa TA, Mai ML, Melton LB, Hays SR, Goldstein RM, Levy MF, Klintmalm GB. End-stage renal disease (ESRD) after orthotopic liver transplantation (OLTX) using calcineurin-based immunotherapy: risk of development and treatment. Transplantation 2001;72:1934-1939. 2. Sherman DS, Fish DN, Teitelbaum I. Assessing renal function in cirrhotic patients: problems and pitfalls. Am J Kidney Dis 2003;41:269-278. 3. Gonwa TA, Jennings L, Mai ML, Stark PC, Levey AS, Klintmalm GB. Estimation of glomerular filtration rates before and after orthotopic liver transplantation: evaluation of current equations. Liver Transpl 2004;10:301-309. 4. Levey AS, Bosch JP, Lewis JB, Grenne T, Rogers N, Roth D. A more accurate method to estimate glomerular filtration rate from serum creatinine: a new prediction equation. Modification of Diet in Renal Disease Study Group. Ann Intern Med 1999;130:461-470. 5. Woitas RP, Stoffel-Wagner B, Flommersfeld S, Poege U, Schiedermaier P, Klehr HU, et al. Correlation of serum concentrations of cystatin C and creatinine to inulin clearance in liver cirrhosis. Clin Chem 2000;46:712-715. 6. Schuck O, Gottfriedova H, Maly J, Jabor A, Stollova M, Bruzkova I, et al. Glomerular filtration rate assessment in individuals after orthotopic liver transplantation based on serum cystatin C levels. Liver Transpl 2002;8:594-599. 7. Samyn M, Cheeseman P, Bevis L, Taylor R, Samaroo B, Buxton-Thomas M, et al. Cystatin C, an easy and reliable marker for assessment of renal dysfunction in children with liver disease and after liver transplantation. Liver Transpl 2005;11:344-349. 8. Biancofiore G, Pucci L, Cerutti E, Penno G, Pardini E, Esposito M, et al. Cystatin C as a marker of renal function immediately after liver transplantation. Liver Transpl 2006;12:285-291. 9. Filler G, Lepage N. Should the Schwartz formula for estimation of GFR be replaced by cystatin C formula? Pediatr Nephrol 2003;18:981-985. 10. Hoek FJ, Kemperman FA, Krediet RT. A comparison between cystatin C, plasma creatinine and the Cockcroft and Gault formula for the estimation of glomerular filtration rate. Nephrol Dial Transplant 2003;18:2024-2031. 11. Larsson A, Malm J, Grubb A, Hansson LO. Calculation of glomerular filtration rate expressed in ml/min from plasma cystatin C values in mg/l. Scand J Clin Lab Invest 2004;64:25-30. 12. Grubb A, Bjork J, Lindstrom V, Sterner G, Bondesson P,

1672 GERHARDT ET AL. Nyman U. A cystatin C-based formula without anthropometric variables estimates glomerular filtration rate better than creatinine clearance using the Cockcroft-Gault formula. Scand J Clin Lab Invest 2005;65:153-162. 13. Grubb A, Nyman U, Bjork J, Lindstrom V, Rippe B, Sterner G, Christensson A. Simple cystatin C-based prediction equations for glomerular filtration rate compared with the modification of diet in renal disease prediction equation for adults and the Schwartz and the Counahan- Barratt prediction equations for children. Clin Chem 2005;51:1420-1431. 14. Sjostrom P, Tidman M, Jones I. Determination of the production rate and non-renal clearance of cystatin C and estimation of the glomerular filtration rate from the serum concentration of cystatin C in humans. Scand J Clin Lab Invest 2005;65:111-124. 15. Russell CD, Bischoff PG, Kontzen FN, Rowell KL, Yester MV, Lloyd LK, Tauxe WN, et al. Measurement of glomerular filtration rate: single injection plasma clearance method without urine collection. J Nucl Med 1985;26: 1243-1247. 16. Levey AS, Greene T, Kusek JW, Beck GJ, Group. ams. Simplified Equation to Predict Glomerular Filtration Rate from Serum Creatinine. American Society of Nephrology Renal Week 2000; A0828. 17. Walser M. Assessing renal function from creatinine measurements in adults with chronic renal failure. Am J Kidney Dis 1998;32:23-31. 18. National Kidney Foundation. K/DOQI clinical practice guidelines for chronic kidney disease: evaluation, classification, and stratification. Am J Kidney Dis 2002;39:S1-266. 19. Bland JM, Altman DG. Comparing methods of measurement: why plotting difference against standard method is misleading. Lancet 1995;346:1085-1087. 20. Woitas RP, Stoffel-Wagner B, Poege U, Schiedermaier P, Spengler U, Sauerbruch T. Low-molecular weight proteins as markers for glomerular filtration rate. Clin Chem 2001; 47:2179-2180. 21. Cockcroft DW, Gault MH. Prediction of creatinine clearance from serum creatinine. Nephron 1976;16:31-41. 22. Nankivell BJ, Gruenewald SM, Allen RD, Chapman JR. Predicting glomerular filtration rate after kidney transplantation. Transplantation 1995;59:1683-1689. 23. Laterza OF, Price CP, Scott MG. Cystatin C: an improved estimator of glomerular filtration rate? Clin Chem 2002; 48:699-707. 24. Filler G, Bokenkamp A, Hofmann W, Le Bricon T, Martinez-Bru C, Grubb A. Cystatin C as a marker of GFR history, indications, and future research. Clin Biochem 2005;38:1-8. 25. Poge U, Gerhardt T, Palmedo H, Klehr HU, Sauerbruch T, Woitas RP. MDRD equations for estimation of GFR in renal transplant recipients. Am J Transplant. 2005;5:1306-1311. 26. Hallan S, Asberg A, Lindberg M, Johnsen H. Validation of the Modification of Diet in Renal Disease formula for estimating GFR with special emphasis on calibration of the serum creatinine assay. Am J Kidney Dis 2004;44:84-93. 27. Larsen K. Creatinine assay by a reaction-kinetic principle. Clin Chim Acta 1972;41:209-217. 28. Coresh J, Astor BC, McQuillan G, Kusek J, Greene T, Van Lente F, Levey AS. Calibration and random variation of the serum creatinine assay as critical elements of using equations to estimate glomerular filtration rate. Am J Kidney Dis 2002;39:920-929. 29. Risch L, Herklotz R, Blumberg A, Huber AR. Effects of glucocorticoid immunosuppression on serum cystatin C concentrations in renal transplant patients. Clin Chem 2001;47:2055-2059. 30. White C, Akbari A, Hussain N, Dinh L, Filler G, Lepage N, Knoll GA. Estimating Glomerular Filtration Rate in Kidney Transplantation: A Comparison between Serum Creatinine and Cystatin C-Based Methods. J Am Soc Nephrol 2005;16:3763-3770. 31. de Mattos AM, Olyaei AJ, Bennett WM. Nephrotoxicity of immunosuppressive drugs: long-term consequences and challenges for the future. Am J Kidney Dis 2000;35:333-346. 32. Biggi A, Viglietti A, Farinelli MC, Bonada C, Camuzzini G. Estimation of glomerular filtration rate using chromium-51 ethylene diamine tetra-acetic acid and technetium-99m diethylene triamine penta-acetic acid. Eur J Nucl Med 1995;22:532-536. 33. Mulligan JS, Blue PW, Hasbargen JA. Methods for measuring GFR with technetium-99m-dtpa: an analysis of several common methods. J Nucl Med 1990;31:1211-1219.