Locked plating constructs are creating a challenge for surgeons.

Similar documents
Screw Placement and Types Matter

Distal Femur Fractures in The Elderly The Ideal Construct

Fractures of the tibia shaft treated with locked intramedullary nail Retrospective clinical and radiographic assesment

Failed Subtrochanteric Fracture How I Decide What to Do?

Treatment Alternatives for Pediatric Femoral Fractures

Zimmer Small Fragment Universal Locking System. Surgical Technique

Biomechanics of Fractures and Fixation

Results of tibia nailing with Angular Stable Locking Screws (ASLS); A retrospective study of 107 patients with distal tibia fracture.

Types of Plates 1. New Dynamic Compression Plate: Diaphyseal fracture: Radius, Ulna, Humerus, Rarely tibia

Femoral Fractures in Adolescents: A Comparison of Four Methods of Fixation

PediLoc 3.5mm and 4.5mm Contour Femur Plate Surgical Technique

7/23/2018 DESCRIBING THE FRACTURE. Pattern Open vs closed Location BASIC PRINCIPLES OF FRACTURE MANAGEMENT. Anjan R. Shah MD July 21, 2018.

Intramedullary Nailing: History & Rationale

5/31/2018. Ipsilateral Femoral Neck And Shaft Fractures. Ipsilateral Neck-Shaft Fractures Introduction. Ipsilateral Neck-Shaft Fractures Introduction

Fracture fixation. Types. Mechanical considerations. Biomechanics of fracture fixation. External fixation. Internal fixation

PediLoc 3.5mm and 4.5mm Bowed Femur Plate Surgical Technique

Curriculum Vitae. Daniel C. Fitzpatrick, MD, MS Antigua Drive Eugene, OR (541) July 22, 2008

Olecranon fracture. Lonnie Froberg, MD, Ph.D Rigshospitalet, Copenhagen University Hospital

CASE REPORT. Bone transport utilizing the PRECICE Intramedullary Nail for an infected nonunion in the distal femur

LOCKING TEP LOCKING TITANIUM ELASTIC PIN INTRAMEDULLARY NAIL

JMSCR Vol. 03 Issue 08 Page August 2015

MANAGEMENT OF BILATERAL FRACTURE FEMUR WITH IMPLANT FAILURE: A CASE REPORT

Locked Plating: Clinical Indications

9/24/2015. Nailing IT Fractures: Long vs. Short Technique Tricks. Conflict of Interest. Short vs. Long Hip Nail

AcUMEDr. Anatomic Midshaft Forearm Plates

The study of distal ¼ diaphyseal extra articular fractures of humerus treated with antegrade intramedullary interlocking nailing

Case Report. Antegrade Femur Lengthening with the PRECICE Limb Lengthening Technology

Diaphyseal Humerus Fractures. OTA Course Dallas, TX 1/20/17 Ellen Fitzpatrick MD

Closed reduction and internal fixation of fractures of the shaft of the femur by the Titanium Elastic Nailing System in children.

HUMERAL SHAFT FRACTURES: ORIF, IMN, NONOP What to do?

EVOS MINI with IM Nailing

Locked Plating in Practice: Indications and Current Concepts

Plate and Bone Stresses for Single- and Double-Plated Femoral Fractures. D.R. Carter and R. Vasu

Principles of intramedullary nailing. Management for ORP

BRIDGE PLATING OF COMMINUTED SHAFT OF FEMUR FRACTURES

GAMMA LOCKING NAIL INSTRUMENTS OPERATIVE TECHNIQUE

2017 Resident Advanced Trauma Techniques Course COMPLICATIONS / CHALLENGES MALUNIONS/DEFORMITY

Distal Humerus Fractures: How should they be fixed?

Tibial Shaft Fractures

.org. Tibia (Shinbone) Shaft Fractures. Anatomy. Types of Tibial Shaft Fractures

Nailing Stability during Tibia Fracture Early Healing Process: A Biomechanical Study

Angular Malalignment in Subtrochanteric and Proximal Shaft Femur Fractures after Intramedullary Nailing using SIGN Nails

Practical Reduction Techniques: Diaphyseal Reduction. Philip Wolinsky University of California at Davis Medical Center

Advantage and limitations of a minimally-invasive approach and early weight bearing in the treatment of tibial shaft fractures with locking plates

Study of Ender s Nailing in Paediatric Tibial Shaft Fractures

Ethan M. Braunstein, M.D. 1, Steven A. Goldstein, Ph.D. 2, Janet Ku, M.S. 2, Patrick Smith, M.D. 2, and Larry S. Matthews, M.D. 2

Lengthening & Deformity correction with. Fixator Assisted Nailing

Elbow Fractures ORIF VS Arthroplasty

Zimmer Small Fragment Universal Locking System

Case Presentation: Comminuted Fractures of the Proximal Ulna 11/28/2017. Disclosures. Surgical Strategy. Implant Choice. Melvin P.

THE RING BUTTERFLY FRAGMENT

Comparative Study of Fixation Devices for Intertrochanteric Fractures

Optimum implant geometry

Designing a Novel Fixation Device for Pediatric Orthopaedic Tibia Fractures

4/28/2010. Fractures. Normal Bone and Normal Ossification Bone Terms. Epiphysis Epiphyseal Plate (physis) Metaphysis

9/24/2015. When Can I Use a SHS? When CAN T I Use a SHS? Sliding Hip Screw. Time proven. Technically simple. Cheap. Quick

Comparitive Study between Proximal Femoral Nailing and Dynamic Hip Screw in Intertrochanteric Fracture of Femur *

Tibial Nonunions: Should I Tackle and How

Orthopedics in Motion Tristan Hartzell, MD January 27, 2016

A Clinical Study For Evaluation Of Results Of Closed Interlocking Nailing Of Fractures Of The Shaft Of The Tibia

A comparative study of less invasive stabilization system and titanium elastic nailing for subtrochanteric femur fractures in older children

PERIPROSTHETIC FEMUR FRACTURES AFTER THA: Treatment with Revision

Recurrent Fifth Metatarsal Fractures. Carol Frey MD Fellowship Co - Director West Coast Sports Medicine Foundation UCLA Manhattan Beach, California

Case Reports RETROGRADE INTRAMEDULLARY NAILING FOR NONUNIONS OF SUPRACONDYLAR FEMUR FRACTURE OF OSTEOPOROTIC BONES

S U R G I C A L T E C H N I Q U E David A. McQueen, MD Return to Menu

AcUMEDr. LoCKING CLAVICLE PLATE SYSTEM

Low energy fractures: what is the difference? specific features and clinical outcomes by minimally invasive locking plates.

Relationship between the Apex of Flexible Nail and the Level of Fracture: A Biomechanical Study Ahmed N* 1, Gakhar H 2, Cheung G 3, Sharma A 4

A locking plate system that expands a surgeon s options in trauma surgery. Zimmer NCB Plating System

ISSN (O): ; ISSN (P): Short Term Evaluation of Distal Femoral Fracture Fixation by Locking Plate.

The Flower Medial Column Fusion Plate

Locked Plating: Biomechanics and Biology

2016 SIGN Conference: Treatment of Difficult Fractures Around The World

A locking plate system that expands a surgeon s options in trauma surgery. Zimmer NCB Plating System

Wichita Fusion Nail Surgical Technique. David A. McQueen, MD

DLS The biomechanical effects of dynamic locking screws

A prospective study of treatment of distal femur fractures with locking condylar plate

Pediatric Tibia Fractures Key Points. Christopher Iobst, MD

LISS DF and LISS PLT. Less Invasive Stabilization Systems for Distal Femur and Proximal Lateral Tibia.

Case Report Bilateral Distal Femoral Nailing in a Rare Symmetrical Periprosthetic Knee Fracture

Journal of Orthopaedic Surgery and Research 2010, 5:62

Technique Guide. LCP Proximal Femoral Hook Plate 4.5/5.0. Part of the LCP Periarticular Plating System.

Fibula Rod System. Lateral Malleolus Fracture Indications:

Treatment of traumatic conditions of the femur using the Huckstep nail

Young Bones. Characteristics. Klaus Hindsø

Humerus shaft - Reduction & Fixation - Compression plate - AO Surgery Reference. Compression plating

OPERATIVE TREATMENT OF THE INTERCONDYLAR FRACTURE OF THE FEMUR

Tibia fractures are the third most common long bone

Section 20: Fracture Mechanics and Healing 20-1

LCP Condylar Plate 4.5/5.0. Part of the LCP Periarticular Plating System.

Mayo Clinic Congruent Elbow Plate System

A comparative study of locking plate by MIPO versus closed interlocking intramedullary nail in extraarticular distal tibia fractures

Intramedullary Nailing of Subtrochanteric Fractures

Fractures of the Radial and Ulnar Shafts In the Pediatric Patient

FIRST DESCRIBED RETROGRADE TECHNIQUE USING MEDIAL EPICONDYLE 6/5/2018. RETROGRADE vs. ANTEGRADE FEMORAL NAILING

AO / Synthes Proximal Posterior Medial Tibia Plate. Tibial Plateau Fx. Osteosynthesis

Distal femoral fracture with subsequent ipsilateral proximal femoral fracture

PFNA-II. Proximal Femoral Nail Antirotation.

DISTAL HUMERUS FRACTURES WHAT I HAVE LEARNED DISTAL HUMERUS FRACTURES WHAT I HAVE LEARNED 63 YO WOMAN CT FIXABLE OSTEOTOMY NOT NEEDED

Orthopedic Bone Nail System - Distal Femoral Nail Surgical Technique Manual

Transcription:

Locked plating constructs are creating a challenge for surgeons. Three recent studies examining supracondylar femur fractures show concern for the high degree of stiffness of locked plating constructs and report nonunion rates as high as 23%. 1,2,3 While it is true that a plating construct needs to be strong enough to support the damaged bone while the fracture heals, it is also true that too much stiffness forces the body to heal through osteonal or primary/direct healing. 3 Primary healing requires nearly-perfect anatomic reduction and rigid compression for absolute stability, as well as a complex and unforgiving procedure. 4 Figure 1 illustrates how locked plating constructs will bend to create motion and callus formation on the far cortex. This can lead to delayed union or nonunion issues if the fracture does not heal before the plate breaks. Asymmetric Gap Closure near cortex: minimal motion far cortex: maximal motion Figure 1 1. Boulton C, Chacko A, Appleton P, Rodriguez E: Factors For Increased Failure Rate of Locked Plating in the Treatment of Distal Femoral Fractures. Poster presented at the 78th Annual Meeting of the American Academy of Orthopaedic Surgeons, February 15-19, 2011, San Diego, CA. 2. Gross J, Serna F, Lybrand K, Qui X, Humphrey C, Gorczyca J: Surgical Approach Does Not Affect Union of Supracondylar Femur Fractures Treated with Plate Fixation. Poster presented at the 78th Annual Meeting of the American Academy of Orthopaedic Surgeons, February 15-19, 2011, San Diego, CA. 3. Henderson CE, Lujan TJ, Kuhl LL, Bottlang M, Fitzpatrick DC, Marsh JL: Healing Complications are Common after Locked Plating for Distal Femur Fractures. Clin Orthop Relat Res 2011; 469(6):1757-1765. 4. Skirving AP, Day R, Macdonald W, McLaren R: Carbon Fiber Reinforced Plastic (CFRP) Plates Versus Stainless Steel Dynamic Compression Plates in the Treatment of Fractures of the Tibiae in Dogs. Clin Orthop Relat Res 1987; 224:117-124.

MotionLoc Technology answers that challenge with controlled movement. Zimmer is using far cortical locking technology as a strategy to reduce the stiffness of a locked plating construct without losing construct strength. MotionLoc Technology generates parallel motion at the fracture site through elastic flexion of the screws to actively promote secondary bone healing circumferentially across the entire fracture gap. Concept: MotionLoc screws lock in the plate and the far cortex of diaphyseal bone. MotionLoc screws have a reduced diameter mid-shaft to bypass the near cortex. Under load, the screw will elastically flex to create interfragmentary motion at the fracture site until the shaft of the screw contacts the near cortex for added support and load sharing. Figure 2 Reduced Stiffness: MotionLoc screws provide flexible fixation by elastic bending of screw shafts. MotionLoc screws reduced the initial axial stiffness of a locked plating construct by up to 64% *. Bi-Phasic Stiffness: At elevated loading and flexion, the near cortex of the bone will support the flexing screw shaft to provide a stiffness increase and reinforce the strength of the loading curve of a locked plating construct. locked plate Figure 3 Parallel Motion Parallel Motion: The elastic deformation of the MotionLoc screws translates to nearly parallel micromotion at the fracture site. With a standard locking construct in a bridging technique, micromotion is only created at the far cortex. near cortex axial load far cortex near cortex support Load Distribution: MotionLoc constructs provide evenly distributed load sharing among all MotionLoc screws. In contrast, the end-screw of a standard locked construct induces a stress riser, which reduces construct strength in bending and torsion. 5 Figure 4 Bi-Phasic Stiffness parallel interfragmentary motion 5. Bottlang, M. Doornick, J., Byrd, G., Fitzpatrick, DC, Madey, SM, A non-locking end screw can decrease fracture risk caused by locked plating in the osteoporotic diaphysis. JBJS-A, 91(3): 620-627, 2009. * Data on file at Zimmer. Please reference ZRR 2198-10-REV2

Observational study demonstrates faster and stronger healing with MotionLoc Technology. Thirty-one consecutive patients with 33 distal fractures (AO/OTA types 33 A-C) were prospectively enrolled at three trauma centers. Thirty-one fractures were available for follow-up until union or revision. Patients were followed up for a minimum of 1 year with functional and radiographic assessment obtained at post-operative weeks 6, 12 and 24, including a computed topography scan at week 12. In total, 125 MotionLoc screws were used in the study. None of them broke or lost fixation and only one of the patients displaced into varus. Thirty of 31 fractures healed within 15.6 ± 6.2 weeks (Figure 7A). Seventy-four percent of fractures formed periostal callus that extended to the lateral cortex under the plate. This suggests a direct effect of dynamization with MotionLoc screws on callus distribution. 6 Compared to these historic control data of 66 distal femur fractures stabilized with locking plates using standard locking screws, dynamic fixation in the present study yielded an on average increase in periostal callus size of 48% at week 6 (p=0.12), 72% at week 12 (p=0.02), and 113% at week 24 (p=0.001). Figure 5: Outcomes Data Parameter Results Comments Enrolled: 31 patients with 33 fractures Available for evaluation: 29 patients with 31 fractures Follow-up: Week 6: 31 fractures Week 12: 29 fractures Two patients refused CT Week 24: 31 fractures One patient died at week 20 One year: 30 fractures Implant breakage: 0 Fixation failure 0 Complications: One mal-reduction in 20 rotation Reoperation at day 5 post-op to correct malrotation One hypertrophic nonunion Reoperation with reamed nail at week 24 Varus migration [ ]: 1.0 + 1.9, range -3.3 to 5.9 Only one fracture had >5 varus migration Bridging ( > 2 cortices): Week 6: 2 fractures (6%) Week 12: 19 fractures (39%) Week 24: 30 fractures (98%) Weight bearing [kg]: Week 6: 37 + 25, range 0-90 Week 12: 66 + 29, range 0-107 One patient with nonunion was unable to bear weight Week 24: 77 + 25, range 0-114 One patient with nonunion was unable to bear weight Contact your Zimmer sales rep for the complete study results and analysis. 6. Clinicaltrials.gov, Identifier NCT01667887

MotionLoc fixation in 76-year-old female patient weighing 157 kg Pre-Op Post-Op Week 6 Week 12 Week 24 Figure 6: Durability of fixation in presence of excessive weight-bearing in an ambulating patient with a body mass index of 56, weighing 157 kg. 6 Periosteal Callus Size Periosteal Callus Distribution Circumferential Periosteal Callus A B C Figure 7: Periosteal callus assessment: A) Average size of projected periosteal callus area at the medial, anterior, and posterior aspects. B) Periosteal callus distribution, shown to scale for different time points and locations. Percentages refer to the distribution of callus at a specific time. For example, of the total periosteal callus at week 6, 35%, 30% and 35% was deposited at the posterior, anterior, and medial cortex, respectively. C) Circumferential periosteal callus included callus formation on the lateral aspect adjacent to the plate.6 6. Clinicaltrials.gov, Identifier NCT01667887

Why MotionLoc Technology? Get your answer straight from these surgeons. I have continued to use MotionLoc because of the clinical results I have seen thus far. I have been impressed with the early callus formation, the overall rate of union, and patient satisfaction. I would recommend MotionLoc to other physicians as a valuable tool, if they are having difficulties in getting fractures of the distal femur to heal reliably or are experiencing issues with implant failure due to nonunion. Chinedu Nwosa, MD Des Moines, IA With MotionLoc I m seeing healing not only at a faster rate, but also more consistent callus formation circumferentially around the fracture site. The amount of healing I m seeing is significantly greater than the bone formation I ve seen with other techniques. Gregory Tennant, DO* Fontana, CA Far Cortical Locking Technology has been extensively researched in lab and animal models with documentation of its improvement in the biomechanical aspects of fracture healing; much more than any other plating technology that has become available. When using the Zimmer adaptation of Far Cortical Locking Technology, or the MotionLoc screw, I have not had any fractures become nonunions. MotionLoc makes sense for the progression in fracture care where we have learned that providing a suitable biologic environment for healing is important. Adding a more suitable biomechanical environment to our current treatment, in my opinion, will reduce the number of nonunions in current practice. Michael Tilley, MD* Kansas City, KS * Dr. Gregory Tennant and Dr. Michael Tilley are paid consultants for Zimmer, Inc.

Patient One Information 89-year-old female, 152 lbs. Ground Level fall Comminuted supracondylar periprosthetic femur fracture She was treated with an NCB Periprosthetic Distal Femur Plate, NCB Cancellous screws, and MotionLoc screws. Follow up x-rays were taken at 24 weeks post-op and show circumferential callus bridging across the fracture site. Patient Two Information 58-year-old male Motorcycle accident Multiple extremity injuries The patient was treated with the NCB straight-narrow plate and MotionLoc screws. Follow-up x-rays were taken at 6 weeks post-op and show circumferential callus bridging around the fracture site.

Patient One: Pre-Op Patient One: 3 months

Patient Two: Pre-Op Patient Two: 3 months