micromend Skin Closure Device Pre-clinical Studies of Closure of Surgical Wounds in Live Pigs

Similar documents
Adhesive strips for the closure of surgical wounds: a systematic review and meta-analysis

DERMABOND PRINEO SKIN CLOSURE SYSTEM (22 CM)

Surgery and Crohn s. Crohn s Disease 70 % Why Operate? Complications of Disease. The Gastrointestinal Tract. Surgery for Inflammatory Bowel Disease


Positioning System. Laparoscopic ventral hernia repair KEY BENEFITS SOFT TISSUE REPAIR

Robot Assisted Rectopexy

Placing PEG and Jejunostomy Tubes in Dogs and Cats

Transfemoral Amputation

Extracapsular Repair Monofilament Nylon Suture

Mr John Groom The Complete Guide to Hernia

NovoSorb BTM. A unique synthetic biodegradable wound scaffold. Regenerating tissue. Changing lives.

White Paper. Wound Closure

Our Experience with Endoscopic Brow Lifts

Trocar Essentials. High quality, cost effective, single use Trocars

Advanced Wound Management: Nine Myths and Realities (2008)

DermaSpan Acellular Dermal Matrix. Reinforcement of Ruptured Posterior Tibial Tendon Repair. Surgical Protocol by Charles Zelen, DPM, FACFAS

ROBOTIC ASSISTED LAPAROSCOPIC PYELOPLASTY (RALP) Does The Patients Weight Effect The Surgical Results? Boris Chertin MD

Some of the ophthalmic surgeries

Southmedic s Dynamic Tissue Systems. Control Reduce Close

Laparoscopic Salpingectomy for Ectopic Pregnancy Simulation

Principles of plastic and reconstructive surgery

SURGICAL TECHNIQUE THE TENDON ANCHOR SYSTEM

How-To Booklet: Pediatric Spay-Neuter. Surgical Techniques Pictorial

Body Contouring Implants - Calf

BEN C. TAYLOR, MD TRAUMA FELLOW GRANT MEDICAL CENTER

Three steps for post-operative care. Give your patients the closure they need.

(FIG.1) Landmarks of the external ear in dogs. (FIG.2) Anatomy of the ear.

ThruPort Ergonic Minimal Incision Instrumentation

JuggerKnot Soft Anchor 1.0 mm Mini

OptiFix Absorbable Fixation System

All surgery carries some uncertainty and risk

EndoBlade Soft Tissue Release System

Delayed Primary Closure of Diabetic Foot Wounds using the DermaClose RC Tissue Expander

Laparoscopic Right Colectomy

B. Braun Mesh Range It s All about Prevention. Experts in Abdominal Wall Health. Hernia Repair

COMPARING KIRSCHNER WIRE FIXATION TO A NEW DEVICE USED FOR PROXIMAL INTERPHALANGEAL FUSION

IS THE LAP-BAND RIGHT FOR ME?

No Drain Abdominoplasty: No More Excuses. Karol A Gutowski, MD, FACS

Fibula Rod System. Lateral Malleolus Fracture Indications:

Ludwig-Maximilians-Universität PROCEEDINGS. European Society of Veterinary Orthopaedics and Traumatology

DIGESTIVE HEALTH ENTERAL FEEDING PRODUCTS

Force Characteristics of Trocar Insertion Abdomen in Laparoscopic Surgery

Mommy Makeover

Surgical jejunostomy, DEPJ or PEGJ

Surgical Pearls in the Management of Body Contouring by Liposculpture from Fournier s Syringe to Lipomatic

with Laparoscopic Ventral Hernia Repair Positioning System SOFT TISSUE REPAIR Designed for Accurate Mesh Centering

Cystotomy Laboratory Simulation

Boonlawat Homvises MD* * Department of Surgery, Faculty of Medicine, Thammasat University, Pathumthani, Thailand

radially expanded, and tissues are stretched not cut. substantial axial force to penetrate the abdominal

The pillars defining our quality care. We Care!

Better Post-Op Pain Control Starts Here

Case Report. RapidSorb Rapid Resorbable Fixation System. Ridge augmentation in a one-step surgical protocol.

Comparative Study Of Laparoscopic Versus Open Peptic Perforation Closure

Port Access Laparoscopic Cannulas and Trocars

Strength and Predictability. Zimmer Collagen Repair Patch

No Drain Abdominoplasty: No More Excuses. Karol A Gutowski, MD, FACS Instructional Course


Primary Coverage. The Benefits of Circumcision Operation Principle Academic Article Circumstapler Advantages Operating Procedure Post Operation Caring

M A H O M E W O R K # 2 P a g e Outpatient surgery is generally limited to procedures requiring less than 60

LAPAROSCOPIC HERNIA REPAIR

Hernias Umbilical Hernia When to See a Surgeon? What Are Symptoms of an Umbilical Hernia? How is Repair Performed?

Smart Solutions for Serious Wounds. An advanced bilayer dermal regeneration matrix FDA approved for the treatment of diabetic foot ulcers.

2013 MCT CPC-H Quiz #8 Chapters 13 and 14

Chapter 24. Arthroscopic Thumb Carpometacarpal Interposition Arthroplasty. Introduction. Operative Technique. Patient Preparation and Positioning

BUNNELL. Expanded product line Customer service Please visit BunnellSplints.com Sizing information on back page WRIST HAND FINGER ORTHOSIS

AcUMEDr. Locking Proximal Humeral Plate. PoLARUSr PHPt

Surgical Technique. CONQUEST FN Femoral Neck Fracture System

Cochlear Baha Attract Surgery. Aurélie Dewael Education Manager Cochlear Academy EMEA

CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE

Breast Reconstruction Postmastectomy. Using DermaMatrix Acellular Dermis in breast reconstruction with tissue expander.

Hysterectomy. What is a hysterectomy? Why is hysterectomy done? Are there alternatives to hysterectomy?

SCIENTIFIC PAPER ABSTRACT INTRODUCTION MATERIALS AND METHODS

SAVI SCOUT radar localization was developed to make breast surgery easier for women.

Evaluation of the wound healing response post deep dermal heating by fractional RF: INTRAcel

Provision of Rotational Stability: Prevention of Collapse: Closed Fracture Reduction: Minimally Invasive Surgery with no Exposure of the Fracture:

Case Study. TRAM Flap Reconstruction with an Associated Complication. Repair using DermaMatrix Acellular Dermis.

THE MEMORY STAPLE SURGICAL TECHNIQUE

Goals of Care. Restore shape and function after cancer

Innovative Range of Regenerative Solutions

Scientific Forum. Nostrilplasty: Raising, Lowering, Widening, and Symmetry Correction of the Alar Rim

SINGLE INCISION ENDOSCOPIC SURGERY (SIES)

Torn ACL Hamstring Graft

NOTES NOTES???? 9/7/2009. M. Hagen. Center for the Future of Surgery University of California San Diego

Humanity s Vision Is Our Focus. The Ahmed Glaucoma Valve

ISPUB.COM. S Saad, E Shakov, V Sebastian, A Saad INTRODUCTION METHODS CASE REPORT 2 CASE REPORT 3 CASE REPORT 1

Understanding SCOUT. Procedure

INGUINAL HERNIA REPAIR PROCEDURE GUIDE

JuggerKnot Soft Anchor 1.0 mm Mini

ORIGINAL ARTICLE. A Prospective Controlled Study of Wound-Healing Characteristics. glues have been investigated

RECONSTRUCTION OF SUBTOTAL DEFECTS OF THE NOSE BY ABDOMINAL TUBE FLAP. By MICHAL KRAUSS. Plastic Surgery Hospital, Polanica-Zdroj, Poland

The next generation in all suture implant technology. Q-FIX All-Suture Implants

Farah S, Kiyingi A, Leinkram C. The Melbourne Hernia Clinic Masada Hospital 26 Balaclava Road St Kilda East Victoria, Australia 3168.

Minimally Invasive Surgery Tool. Team Members: Sujan Bhaheetharan (BWIG) Ashley Huth (BSAC) Max Michalski (Communicator) Brenton Nelson (Leader)

7/11/17. The Surgeon s Operative Report: Tools and Tips to Enhance Abstraction. Stopwoundinfection.com. Impact to Healthcare

Facing Gallbladder Surgery?

Patient Safety in Postbariatric Body Contouring. Karol A Gutowski, MD, FACS

No Drain Abdominoplasty with Progressive Tension Sutures. Karol A Gutowski, MD, FACS

Hernia. emoryhealthcare.org

Transcription:

micromend Skin Closure Device Pre-clinical Studies of Closure of Surgical Wounds in Live Pigs RONALD BERENSON, M.D. and PAUL LEUNG, M.S. EXECUTIVE SUMMARY KitoTech Medical has developed a revolutionary wound closure product, micromend, which combines the ease of application of a bandage with the anchoring strength of sutures and staples. The two porcine studies reported here demonstrate that micromend is able to achieve excellent closure of surgical wounds. In the first study, micromend was compared to sutures, and was shown to be as effective in closing port site wounds. The second study demonstrated outstanding cosmetic results when micromend was used to close 12cm surgical incisions. Wounds closed with micromend devices showed equivalent tensile strength to sutures during the wound healing process. These results combined with its many other advantages, including ease of use, time savings, reduced pain, elimination of the need for return clinic visits for device removal, reduced risk of needle sticks, and consistent and reproducible results, make micromend an attractive alternative to sutures and staples for wound closure. INTRODUCTION There continues to be a need for improved wound closure products that can address the current limitations of suture and staples, which include inflammation and scarring, variable results, risk of infections, and the need for return clinical visits for removal. In the emergency room and clinics, there is also a need to reduce pain associated with use of sutures and staples. Finally, sutures take considerable time to use, which adds costs to surgery and other procedures requiring wound closure. Clinical performance of the micromend skin closure device was tested in pre-clinical studies conducted on juvenile pigs whose skin is similar to that of humans. Two pre-clinical studies were conducted evaluating the use of micromend to close port site wounds produced by trochar insertion (Study 1), and 12cm linear surgical incisions (Study 2). MATERIALS AND METHODS micromend wound closure device micromend is a disposable device with two arrays of tiny microstaples attached to an adhesive backing in the shape and size of a butterfly closure (Figure 1). The microstaples enable anchoring of the device into the skin making it possible to close dermal wounds currently closed using sutures and staples. micromend is rapid and easy to use, and is relatively painless upon application.

Figure 1. micromend Device Study Procedures General Full-thickness wounds in the skin were made in the abdomen of juvenile pigs. The wounds were closed with either micromend devices or sutures in Study 1, while only micromend devices were used to close wounds in Study 2. No other wound closure products were used to close the wounds in either study. All wounds were covered with Tegaderm (3M). Evaluations were performed serially via observations by surgical staff over a three-week period, including placement of devices and sutures (Day 0), as well as on subsequent days at intervals of 2-3 days. Wounds were assessed for evidence of inflammation, wound dehiscence, infection, cosmetic results, and any other abnormalities. Photographs were obtained at Day 0, and on Days 10 and 20 to document healing of the wounds. Wound tensile strength was measured on Days 10 and 20. Tensile strength testing was performed by a standard procedure that utilizes a servo-hydraulic material testing machine. Skin samples were excised using a dog-bone template, and underwent tensile strength testing within an hour of their removal. The skin samples were loaded quasi-statically under tension until construct failure. A custom designed fixture was used to rigidly fix the distal portions of each sample to the testing machine platform (Figure 2). All displacement loads were applied orthogonal to the wound, causing the wound to be loaded across its length. Each sample was loaded until failure at a rate of 40 mm/sec. Force (N) and displacement (mm) data was collected at a rate of 100 Hz. Figure 2: Skin sample placed within custom designed load fixtures

Specific Procedures Study 1 Trocar wounds (port site wounds) were made using a standard laparoscopic instrument that was inserted in the lateral dorsal surface of both sides of the abdomen. (Figures 3A and 3B). The trocar had a diameter of 1.2cm and was inserted through all skin layers. The wound was then closed with one micromend device (Figure 3C) or one suture (3-0 Nylon). Excellent wound approximation was achieved using the micromend device. A total of 36 wounds were closed with micromend, while 12 wounds were closed with sutures in nine pigs. Figure 3: Trochar wound and micromend closure A) Trochar insertion B) Port site wound C) micromend closure Specific Procedures Study 2 Incisions, which were 12cm in length, were made using a scalpel to generate linear wounds in the skin (Figure 4A). The wounds were made in a cephalad to caudal direction with one wound made on each side of the abdomen. Ten micromend devices were applied adjacent to one another to close each wound (Figure 4B). Excellent wound approximation was achieved using micromend devices. A total of 6 wounds were closed with micromend devices in three pigs. Figure 4: Surgical incision and closure A) 12cm surgical incision B) micromend wound closure

RESULTS Study 1 Excellent wound closure results were documented in all wounds closed with micromend devices. No wounds showed significant inflammation, and there was no evidence of wound dehiscence or infections in any of the closed wounds. At Days 10 and 20, excellent wound healing and appearance was observed in wounds closed with micromend. (Figure 5). A Comparison of wounds closed with sutures and micromend showed no significant differences in wound healing or appearance. Figure 5: Appearance of 10 wounds closed with micromend devices (Day 20) Wound tensile strength measured in Newtons (N) was equivalent between wounds closed with sutures and staples at Days 10 and 20 (Table 1). At Day 20, micromend closed wounds had approximately 20N of tensile strength per cm of wound length (note: wounds were approximately 1.2cm wide). Table 1: Wound Tensile Strength Time Point micromend Suture Day 10 Day 20 12.7 ± 1.3 N (n=36) 23.9 ± 1.4 N (n=12) 13.8 ± 2.9 N (n=18) 21.2 ± 4.8 N (n=6) The median time to close each wound (1.2cm width) with one micromend device was 11 seconds (range: 7-19), while the median time to close each wound with one suture was 32 seconds (range: 20-42). Consequently, wound closure with the micromend device was 3 times faster than with the suture. Study 2 For all 6 wounds, there was no evidence of wound dehiscence, infection, significant inflammation or other abnormalities. Results on Day 20 showed excellent wound healing and appearance for each wound (Figure 6). (Note: the brown patches are dried blood resulting

from the original incisions and are observed with closure using sutures and other devices). Figure 6: Appearance of wounds (Day 20) Wound tensile strength averaged 301+/-49N, which translates into approximately 25N per cm of wound length. The total time to close the 12cm wounds was a median of 127 seconds (range: 121-187 seconds) while the median time to close each 1cm of wound length was approximately 11 seconds (range: 12-18). CONCLUSION The current studies demonstrate that micromend devices can be used to provide effective wound closure for both short and long wounds associated with surgery. These include both port sites due to insertion of trocar instruments in minimally invasive surgeries (laparoscopic and robotic), as well as surgical incisions associated with open surgeries. Reproducible results were observed with excellent wound healing and appearance. There was no evidence of wound dehiscence, infections, or significant inflammation in any wound. Wound approximation was excellent in both studies. In Study 1 where closure with sutures and micromend were compared, there were no differences in wound healing or appearance In Study 2, close wound approximation across the entire length of the wounds was noteworthy, and likely contributed to the excellent cosmetic results achieved in all long wounds.. In addition, wounds closed with micromend achieved equivalent tensile strength to sutures at Days 10 and 20. The surgeon indicated that closure with micromend devices was simple and straightforward (data not shown) for both short and long wounds. Consistent with this observation, closing port site wounds was 3 times faster with micromend than with sutures. For the long surgical wounds, closure was achieved at a similar speed per cm of wound length to that achieved with closing the shorter port site wounds. The long surgical incisions were closed in

approximately 2 minutes. Previous studies have documented that closure of surgical skin incisions takes approximately 30 seconds to a minute for each cm of wound length. If we assume similar closure time in the current study, it would take 6-12 minutes to close the 12cm long wounds with sutures. micromend is projected to be 3-6 times faster in closing these wounds. To learn more, go to www.micromend.com