TECHNICAL BULLETIN. C-Peptide EIA Kit for serum, plasma, culture supernatant, and cell lysates. Catalog Number RAB0326 Storage Temperature 20 C

Similar documents
TECHNICAL BULLETIN. GLP-1 EIA Kit for serum, plasma, culture supernatant, and cell lysates. Catalog Number RAB0201 Storage Temperature 20 C

TECHNICAL BULLETIN. Ghrelin EIA Kit for serum, plasma, culture supernatant, and cell lysates. Catalog Number RAB0207 Storage Temperature 20 C

TECHNICAL BULLETIN. Catalog Number RAB0447 Storage Temperature 20 C

TECHNICAL BULLETIN. Phospho-Akt (pser 473 ) ELISA Kit for detection of human, mouse, or rat phospho-akt (pser 473 ) in cell and tissue lysates

PYY (Human/Mouse/Rat) ELISA Kit

RayBio Human/Mouse/Rat GIP Enzyme Immunoassay Kit

Human TSH ELISA Kit. User Manual

RayBio Human Granzyme B ELISA Kit

RayBio Human ENA-78 ELISA Kit

RayBio Human Thyroglobulin ELISA Kit

STAT1 (ps727) (Human/Mouse) ELISA Kit

STAT3 (py705)/ Pan STAT3 (Human/Mouse/Rat) ELISA Kit

EGFR (py1045)/ Pan EGFR (Human) ELISA Kit

STAT3 (py705) (Human/Mouse/Rat) ELISA Kit

RayBio Human Phosphotyrosine BTK ELISA Kit

RayBio Human Phospho-DDR1 (Tyr792) ELISA Kit

RayBio Human, Mouse and Rat Phospho-NF-kB P65 (Ser536) and Total NF-kB P65 ELISA Kit

RayBio Human Phospho-DDR1 (Tyr792) and Total DDR1 ELISA Kit

RayBio Human Phospho-DDR2 (Tyr740) and Total DDR2 ELISA Kit

EliKine Free Thyroxine (ft4) ELISA Kit

ab Thyroglobulin Human ELISA Kit

RayBio Human/Mouse/Rat Bradykinin Enzyme Immunoassay Kit

ab Insulin Human ELISA Kit

ab Hemoglobin Human ELISA Kit

Mouse C-Peptide ELISA Kit

Human HIV (1+2) antigen&antibody ELISA Kit

Prothrombin (Human) ELISA Kit

Morinaga Mouse C-peptide ELISA Kit

RayBio Human/Mouse/Rat Neurotensin Enzyme Immunoassay Kit

Rat cholesterol ELISA Kit

RayBio Human/Mouse/Rat Oxytocin Enzyme Immunoassay Kit

RayBio Human PPAR-alpha Transcription Factor Activity Assay Kit

Human LDL ELISA Kit. Innovative Research, Inc.

RayBio Human/Mouse/Rat Adiponutrin Enzyme Immunoassay Kit

AssayMax Human Aldose Reductase ELISA Kit

RayBio Human/Mouse/Rat PTH Enzyme Immunoassay Kit

RayBio Human/Mouse/Rat Copeptin Enzyme Immunoassay Kit

Serum Amyloid A ELISA

ab Serum Amyloid P (APCS) Human ELISA Kit

Rat Insulin ELISA. For the quantitative determination of insulin in rat serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

HbA1c (Human) ELISA Kit

RayBio Human/Mouse/Rat Cyclic AMP Enzyme Immunoassay Kit

RayBio Human/Mouse/Rat Amylin Enzyme Immunoassay Kit

02006B 1 vial 02006B 1 vial Store at -20 C. Lyophilized recombinant IL-2

ab Human Citrate Synthase (CS) Activity Assay Kit

Human Apolipoprotein A1 EIA Kit

Human Thyroid-Peroxidase Antibody, TPO-Ab ELISA Kit

RayBio Human/Mouse/Rat Secretin Enzyme Immunoassay Kit

Insulin (Porcine/Canine) ELISA

Canine Thyroid Stimulating Hormone, TSH ELISA Kit

Rat C-peptide ELISA. For the quantitative determination of C-peptide in rat serum

ab Leptin Human ELISA Kit

Procine sphingomyelin ELISA Kit

Mouse C-peptide ELISA

Bovine Insulin ELISA

Mouse C-peptide ELISA

ab Human Hemoglobin subunit alpha SimpleStep ELISA Kit

ab Prothrombin (Factor II) Human ELISA Kit

Porcine/Canine Insulin ELISA

Mouse Leptin ELISA Kit Instructions

SIV p27 Antigen ELISA Catalog Number:

Mouse Ultrasensitive Insulin ELISA

AssayMax Human Ghrelin ELISA Kit

Apolipoprotein A-1 ELISA

Rat C-peptide ELISA. For the quantitative determination of C-peptide in rat serum. For Research Use Only. Not For Use In Diagnostic Procedures.

CoQ10(Coenzyme Q10) ELISA Kit

Rat Proinsulin ELISA

ab Cathepsin D Human ELISA Kit

ab Human Annexin A10 ELISA Kit

ab alpha 1 Microglobulin Human ELISA Kit

Human Cathepsin V ELISA Kit

ab Human Annexin A1 ELISA Kit

For the quantitative measurement of Human Prothrombin concentrations in cell culture supernatants, milk, plasma and urine

ab Apolipoprotein B (APOB) Human ELISA Kit

ab Human GFAP SimpleStep ELISA Kit

Human, Rat, Mouse Melanin Concentrating Hormone (MCH) ELISA Kit

LDL (Human) ELISA Kit

Cotinine (Mouse/Rat) ELISA Kit

Mouse C3 (Complement Factor 3) ELISA Kit

For the quantitative measurement of Apolipoprotein E in mouse serum, plasma, and tissue extract samples.

Human IL-2. Pre-Coated ELISA Kit

Nori Rabbit IL-2 ELISA Kit DataSheet

Estrone EIA kit. For the quantitative determination of estrone in dried fecal extracts, urine and tissue culture media. Cat. No.

YK052 Mouse Leptin ELISA

ab (OH) Vitamin D ELISA kit

human Total Cathepsin B Catalog Number: DY2176

Insulin ELISA. For the quantitative determination of insulin in serum and plasma.

Human Obestatin ELISA

Rabbit Glycated hemoglobin A1c (GHbA1c) ELISA Kit

ab Lipoprotein A (APOA) Human ELISA Kit

GLP-2 (Rat) ELISA. For the quantitative determination of glucagon-like peptide 2 (GLP-2) in rat serum and plasma

ab Human Cathepsin D SimpleStep ELISA Kit

GSI Canine IL-5 ELISA Kit-2 Plates DataSheet

ab Human Leptin SimpleStep ELISA Kit

HIV-1 p24 Antigen ELISA Catalog Number:

ab Human Glycogen Synthase 1 SimpleStep ELISA Kit

EXOTESTTM. ELISA assay for exosome capture, quantification and characterization from cell culture supernatants and biological fluids

Rat Mullerian Inhibiting Substance/Anti-Mullerian hormone, MIS/AMH ELISA kit

Transcription:

C-Peptide EIA Kit for serum, plasma, culture supernatant, and cell lysates Catalog Number RAB0326 Storage Temperature 20 C TECHNICAL BULLETIN Product Description The C-Peptide Enzyme Immunoassay (EIA) Kit is an in vitro quantitative assay for detecting C-Peptide based on the principle of competitive enzyme immunoassay. The microplate in the kit is pre-coated with anti-rabbit secondary antibody. After a blocking step and incubation of the plate with anti-c-peptide antibody, both biotinylated C-Peptide, and peptide standard or targeted peptide in samples interacts competitively with the C-Peptide antibody. Uncompeted (bound) biotinylated C-Peptide then interacts with Streptavidinhorseradish peroxidase (SA-HRP), which catalyzes a color development reaction. The intensity of colorimetric signal is directly proportional to the amount of biotinylated peptide-sa-hrp complex and inversely proportional to the amount of C-Peptide in the standard or samples. This is due to the competitive binding to C-Peptide antibody between biotinylated C-Peptide and peptides in standard or samples. A standard curve of known concentration of C-Peptide can be established and the concentration of C-Peptide in the samples can be calculated accordingly. Components 1. 96-well plate coated with secondary antibody (Item A) - RAB0326A: 96 wells (12 strips x 8 wells) coated with secondary antibody. 2. 20x Wash Buffer (Item B) - RABWASH3: 25 ml 3. EIA C-Peptide standard (Item C) - RAB0326C: 2 vials, 10 ml/vial 4. Anti-C-Peptide Detection Antibody (Item N) - RAB0326F: 2 vials, 5 ml/vial 5. EIA Assay Diluent A (Item D) - RABDIL9: 30 ml, contains 0.09% sodium azide as preservative. Diluent for standards, and serum or plasma samples. 6. EIA 5x Assay Diluent B (Item E) - RABDIL10: 15 ml of 5x concentrated buffer. Diluent for standards, and cell culture media or other sample types. 7. Biotinylated C-Peptide (Item F) - RAB0326G: 2 vials, 20 ml/vial 8. 200x HRP-streptavidin (Item G) - RABHRP3: 600 µl of 200x concentrated HRP-conjugated Streptavidin. 9. C-Peptide Positive Control Sample, Lyophilized (Item M) - RAB0326K: 1 vial, 100 ml 10. TMB Substrate solution (Item H) - RABTMB2: 12 ml of 3,3,5,5 - tetramethylbenzidine (TMB) in buffered solution. 11. Stop Solution (Item I) - RABSTOP2: 8 ml of 0.2 M sulfuric acid. Reagents and Equipment Required but Not Provided. 1. Microplate reader capable of measuring absorbance at 450nm. 2. Precision pipettes to deliver 2 µl to 1 ml volumes. 3. Adjustable 1-25 ml pipettes for reagent preparation. 4. 100 ml and 1 liter graduated cylinders. 5. Absorbent paper. 6. Distilled or deionized water. 7. SigmaPlot software (or other software which can perform four-parameter logistic regression models) 8. Tubes to prepare standard or sample dilutions. 9. Orbital shaker 10. Aluminum foil 11. Saran Wrap Precautions and Disclaimer This product is for R&D use only, not for drug, household, or other uses. Please consult the Material Safety Data Sheet for information regarding hazards and safe handling practices. Preparation Instructions 1. Keep kit reagents on ice during reagent preparation steps. Equilibrate plate to room temperature before opening the sealed pouch. 2. Assay Diluent B (Item E) should be diluted 5-fold with deionized or distilled water.

2 3. Briefly centrifuge the Anti-C-Peptide Antibody vial (Item N) before use. Add 50 µl of 1x Assay Diluent B into the vial to prepare a detection antibody concentrate. Pipette up and down to mix gently. 4. The antibody concentrate should then be diluted 100-fold with 1x Assay Diluent B. This is the anti-c- Peptide antibody working solution, which will be used in Procedure, step 2. Note: The following steps may be done during the antibody incubation procedure (Procedure, step 2). 5. Briefly centrifuge the vial of Biotinylated C-Peptide (Item F) before use. Add 5 µl of Item F to 5 ml of the appropriate Assay Diluent. Pipette up and down to mix gently. The final concentration of biotinylated C-Peptide will be 10 ng/ml. This solution will only be used as the diluent in Preparation, step 6. 6. Preparation of Standards: Label 6 microtubes with the following concentrations: 1,000 ng/ml, 100 ng/ml, 10 ng/ml, 1 ng/ml, 100 pg/ml, and 0 pg/ml. Pipette 450 µl of biotinylated C-Peptide solution into each tube, except for the 1,000 ng/ml (leave this one empty). It is very important to make sure the concentration of biotinylated C-Peptide is 10 ng/ml in all standards. a. Briefly centrifuge the vial of C-Peptide (Item C). In the tube labeled 1,000 ng/ml, pipette 8 µl of Item C and 792 µl of 10 ng/ml biotinylated C- Peptide solution (see step 5). This is your C- Peptide stock solution (1,000 ng/ml C-Peptide, 10 ng/ml biotinylated C-Peptide). Mix thoroughly. This solution serves as the first standard. b. To make the 100 ng/ml standard, pipette 50 µl of C-Peptide stock solution the tube labeled 100 ng/ml. Mix thoroughly. c. Repeat this step with each successive concentration, preparing a dilution series (see Figure 1). Each time, use 450 µl of biotinylated C-Peptide and 50 µl of the prior concentration until 100 pg/ml is reached. Mix each tube thoroughly before the next transfer. d. The final tube (0 pg/ml C-Peptide, 10 ng/ml biotinylated C-Peptide) serves as the zero standard (or total binding). Figure 1. Dilution Series for Standards

3 7. Prepare a 10-fold dilution of Item F. To do this, add 2 µl of Item F to 18 µl of the appropriate Assay Diluent. This solution will be used in steps 8 and 10. 8. Positive Control Preparation: briefly centrifuge the positive control vial (Item M). To the tube of Item M add 101 µl of 1x Assay Diluent B. Also add 2 µl of 10-fold diluted Item F (see step 7) to the tube. This is a 2-fold dilution of the positive control. Mix thoroughly. The positive control is a cell culture medium sample with an expected signal between 10% and 30% of total binding (70-90% competition) if diluted as described above. It may be diluted further if desired, but be sure the final concentration of biotinylated C-Peptide is 10 ng/ml. 9. If Item B (20x Wash Concentrate) contains visible crystals, warm to room temperature and mix gently until dissolved. Dilute 20 ml of Wash Buffer Concentrate into deionized or distilled water to yield 400 ml of 1x Wash Buffer. 10. Sample Preparation: Use Assay Diluent A plus biotinylated C-Peptide to dilute serum/plasma samples. For cell culture medium and other sample types, use 1x Assay Diluent B plus biotinylated C- Peptide as the diluent. For example, to make a 4-fold dilution of sample, mix together 2.5 µl of 10-fold diluted Item F (see step 7), 185 µl of appropriate Assay Diluent, and 62.5 µl of the sample; mix gently. The total volume is 250 µl, enough for duplicate wells on the microplate. Notes: It is very important to make sure the final concentration of the biotinylated C-Peptide is 10 ng/ml in every sample. Do not use Item F diluent from step 5 for sample preparation. If use of undiluted samples is planned, biotinylated C-Peptide must be added to a final concentration of 10 ng/ml. For example, add 2.5 µl of 10-fold diluted Item F to 247.5 µl of sample. 11. Briefly centrifuge the HRP-Streptavidin vial (Item G) before use. The HRP-Streptavidin concentrate should be diluted 200-fold with 1x Assay Diluent B. Note: Do not use Assay Diluent A for HRP- Streptavidin preparation in Step 11. Storage/Stability Store the kit at 20 C. It remains active for up to 1 year. Avoid repeated freeze-thaw cycles. The reconstituted standard should be stored at 20 C or 70 C ( 70 C is recommended). Opened microplate strips or reagents may be store for up to 1 month at 2 8 C. Return unused wells to the pouch containing desiccant pack and reseal along entire edge.

4 Procedure 1. Keep kit reagents on ice during reagent preparation steps. It is recommended that all standards and samples be run at least in duplicate. 2. Add 100 µl anti-c-peptide antibody (see Preparation, step 4) to each well. Incubate for 1.5 hours at room temperature with gentle shaking (1 2 cycles/sec) or incubate overnight at 4 C. 3. Discard the solution and wash wells 4 times with 1x Wash Buffer (200 300 µl each), Washing may be done with a multichannel pipette or an automated plate washer. Complete removal of liquid at each step is essential to good assay performance. After the last wash, remove any remaining Wash Buffer by aspirating or decanting. Invert the plate and blot it against clean paper towels. 4. Add 100 µl of each standard (see Preparation, step 6), positive control (see Preparation, step 8) and sample (see Preparation, step 10) into appropriate wells. Be sure to include a blank well (Assay Diluent only). Cover wells and incubate for 2.5 hours at room temperature with gentle shaking (1 2 cycles/sec) or incubate overnight at 4 C. 5. Discard the solution and wash 4 times as directed in Step 3. 6. Add 100 µl of prepared HRP-Streptavidin solution (see Preparation, step 11) to each well. Incubate for 45 minutes at room temperature with gentle shaking. It is recommended that incubation time should not be shorter or longer than 45 minutes. 7. Discard the solution and wash 4 times as directed in Step 3. Results Calculations Calculate the mean absorbance for each set of duplicate standards, controls and samples, and subtract the blank optical density. Plot the standard curve using SigmaPlot software (or other software which can perform four-parameter logistic regression models), with standard concentration on the x-axis and percentage of absorbance (see calculation below) on the y-axis. Draw the best-fit straight line through the standard points. Percentage absorbance = (B blank OD)/(B o blank OD) where B = OD of sample or standard and B o = OD of zero standard (total binding) Typical Data Standard curve(s) is for demonstration only. Standard curve(s) must be run with each assay. B/B0% 100 80 60 40 20 0 C-Peptide EIA 0.1 1 10 100 1000 Peptide Concentration (ng/ml) 8. Add 100 µl of TMB One-Step Substrate Reagent (Item H) to each well. Incubate for 30 minutes at room temperature in the dark with gentle shaking (1 2 cycles/sec). 9. Add 50 µl of Stop Solution (Item I) to each well. Read absorbances at 450 nm immediately.

5 Product Profile Sensitivity: The minimum detectable concentration of C-Peptide is is 772 pg/ml. Reproducibility: Intra-Assay: CV <10% Inter-Assay: CV <15% Specificity This kit only detects C-peptide, not Insulin A or B chain. Cross Reactivity: This ELISA kit shows no crossreactivity with any of the cytokines tested: Ghrelin, Nesfatin, Angiotensin II, NPY and APC. References 1. Marques, R.G. et al., C-Peptide: much more than a byproduct of insulin biosynthesis. Pancreas, 29(3), 231 8 (2004). 2. Wahren, J. et al., C-Peptide: a new potential in the treatment of diabetic nephropathy. Curr. Diab. Rep., 1(3), 261 6 (2001). 3. Wahren, J., C-Peptide: new findings and therapeutic implications in diabetes. Clin. Physiol. Funct. Imaging, 24(4), 180 9 (2004). 4. Kamiya, H. et al., C-Peptide prevents nociceptive sensory neuropathy in type 1 diabetes. Ann. Neurol., 56(6), 827 35 (2004).

6 Appendix Troubleshooting Guide Problem Cause Solution Inaccurate pipetting Check pipettes Poor standard curve Ensure a brief spin of Item C and dissolve Improper standard dilution the powder thoroughly with gentle mixing. Low signal Too brief incubation times Ensure sufficient incubation time; Procedure, step 2 may change to over night Inadequate reagent volumes or Check pipettes and ensure correct improper dilution preparation Large CV Inaccurate pipetting Check pipettes Review the manual for proper wash. If using High background Plate is insufficiently washed a plate washer, check that all ports are unobstructed. Contaminated wash buffer Make fresh wash buffer Store the standard at < 20 C after Improper storage of the ELISA kit reconstitution, others at 4 C. Keep Low sensitivity substrate solution protected from light Stop solution Stop solution should be added to each well before measurement. KCP,KH,MAM 12/12-1 2012 Sigma-Aldrich Co. LLC. All rights reserved. SIGMA-ALDRICH is a trademark of Sigma-Aldrich Co. LLC, registered in the US and other countries. Sigma brand products are sold through Sigma-Aldrich, Inc. Purchaser must determine the suitability of the product(s) for their particular use. Additional terms and conditions may apply. Please see product information on the Sigma-Aldrich website at www.sigmaaldrich.com and/or on the reverse side of the invoice or packing slip.