M. Velizarova, T. Yacheva and K. Tzatchev Department of Clinical Laboratory and Clinical Immunology, MU Sofia

Similar documents
HAEMATOLOGICAL EVALUATION OF ANEMIA. Sitalakshmi S Professor and Head Department of Clinical Pathology St John s medical College, Bangalore

NOTE: This table will be discontinued after this lot.

Role Of Complete Blood Count In Analysis Of Macrocytosis In Adult Patient Dr Sarat Das 1, Dr Navanita Das 2 1

Automated Quantitation of Hemoglobin-Based Blood Substitutes in Whole Blood Samples

Changes of hematological references depends on storage period and temperature conditions in rats and dogs

A Look Into the Determination of Cell Morphology in Hematology in the 21 st Century. Ramon Simon-Lopez, MD Global Scientific Director Beckman Coulter

Effect of the addition of the antioxidant taurine on the complete blood count of whole blood stored at room temperature and at 4 C for up to 7 days

Sue Jung Kim, MD, MS; Yoonjung Kim, MD; Saeam Shin, MD; Jaewoo Song, MD, MS; Jong Rak Choi, MD, PhD

Apport diagnostique des nouveaux indices érythrocytaires dans l anémie

Scoring System for Detecting Spurious Hemolysis in Anticoagulated Blood Specimens

Full Blood Count analysis Is a 3 part-diff good enough? Dr Marion Münster, Sysmex South Africa

LOOKING BACK TO OUR ROOTS: 80 YEARS OF WINTROBE S INDICES

RBC Histogram as Supplementary Diagnostic Tool with Peripheral Smear Examination in Evaluating Anaemia

Clinical use of flow cytometry

Brief Communication Diagnostic Hematology

The LaboratoryMatters

Collect and label sample according to standard protocols. Gently invert tube 8-10 times immediately after draw. DO NOT SHAKE. Do not centrifuge.

Hematology 101. Cindy Rogers, MT(ASCP) Diagnostics System Specialist

Changes in Automated Complete Blood Cell Count and Differential Leukocyte Count Results Induced by Storage of Blood at Room Temperature

Laboratory for diagnosis of THALASSEMIA

The Egyptian Journal of Hospital Medicine (July 2017) Vol.68 (3), Page

Chapter 2. ERYTHROPOIESIS and ANEMIA

Blutbild 2012: Automatisiert oder manuell? Georg Stüssi Servizio di Ematologia Istituto Oncologico della Svizzera Italiana

EDUCATIONAL COMMENTARY MORPHOLOGIC CHANGES IN PERIPHERAL BLOOD CELLS

Study of RBC histograms in various anemias: A six months prospective study

Evaluation of the Abbott CELL-DYN 4000 Hematology Analyzer

Anemia 1: Fourth year Medical Students/ October/21/ 2015/ Abdallah Abbadi.MD.FRCP Professor

Diagnostic Approach to Patients with Anemia

8.2 Principles of Quantitative Hematologic Determinations (1)

DR SUDHIR MEHTA MD,MNAMS,FICP. Senior Professor & Head Medical Unit SMS Medical College & Hospital Jaipur

Complete Blood Count (CBC)

BONE MARROW PERIPHERAL BLOOD Erythrocyte

American University of Beirut Faculty of Health Sciences Medical Laboratory Sciences Program

Interpreting the CBC. Robert Miller PA Assistant Professor of Clinical Pediatrics and Family Medicine USC Keck School of Medicine Retired

White Blood Cell and Platelet Counting Performance by Hematology Analyzers:A Critical Evaluation

EDUCATIONAL COMMENTARY BLOOD CELL IDENTIFICATION

NEW YORK STATE CYTOHEMATOLOGY PROFICIENCY TEST PROGRAM Glass Slide - November 2016

Utility of automated RBC parameters in evaluation of anemia

American University of Beirut Faculty of Health Sciences Medical Laboratory Sciences Program

How useful are complete blood count and reticulocyte reports to clinicians in Addis Ababa hospitals, Ethiopia?

Iron Deficiency Anemia, β-thalassemia Minor, and Anemia of Chronic Disease. A Morphologic Reappraisal

Evaluation of Anemia. Md. Shafiqul Bari Associate professor (Medicine) SOMC

Anemia In the Insurance Applicant What do the numbers mean?

Changes to CBC Reference Ranges

HEAMATOLOGICAL INDICES AND BONE MARROW BIOPSY

a) Determine the HgB values for the patient samples to fill in the table below. (15 points total) (g/dl) (%) 1 (Female)

EFFECTS OF ZINC SUPPLEMENTATION ON SOME HEMATOLOGICAL PARAMETERS OF SPONTANEOUSLY HYPERTENSIVE RATS

Step 2. Common Blood Tests, and the Coulter Counter Readout

Utilizing Sysmex RET He to Evaluate Anemia in Cancer Patients

Validation of Criteria for Smear Review Following Automated Blood Cell Analysis in Ain Shams University Laboratory

Research Article Erythrocyte and Reticulocyte Indices on the LH 750 as Potential Markers of Functional Iron Deficiency

AVCPT FORMULA GUIDE HEMATOLOGY. Test Formula Example Mean Corpuscular Volume (MCV) Mean Corpuscular Hemoglobin Concentration (MCHC)

Red Cell Indices and Functions Differentiating Patients with the β-thalassaemia Trait from those with Iron Deficiency Anaemia

The Complete Blood Count

Hematology 101. Blanche P Alter, MD, MPH, FAAP Clinical Genetics Branch Division of Cancer Epidemiology and Genetics Bethesda, MD

Sample stability for complete blood cell count using the Sysmex XN haematological analyser

Cbc with differential

The Full Blood Count. Dave Reynders University of Pretoria Paediatric Oncology and Haematology

(anemia) ก hemoglobin concentration, hematocrit deviation 1 1 ก hemoglobin, hematocrit mean corpuscular volume (MCV) 2

Approach to the child with anemia. Nittaya Wisanuyothin,MD. Pediatrics Department, Maharat Nakhonratchasima Hospital

3. Blood Cell Histograms:

Case scenarios in Pediatric Hematology and Oncology. Dr. Zainul Aabideen Consultant, Pediatric Hematology and Oncology Burjeel Hospital

Use of the XE-2100 in a Patient with Cold Auto-immune Hemolytic Anemia

A Study on the Relationship between CBC and EEG for Epilepsy Patients

Hematological profile among Sudanese patients with sickle cell anemia

5/1/2017 DISCUSSION POINTS. Clinical Utility of Immature Cell Indices Beyond the Routine CBC John E. Donnelly BSN, RN

q,a;e Fc ) ORIGINAL EVALUATION. FH9-B 2017 Hematology Auto Differentials, FH9

Differential Blood Smear H3

Complete Blood Count (CBC) Assist.Prof. Filiz BAKAR ATEŞ

USING RETICULOCYTE INDICES TO IDENTIFY α-thalassemia A PRELIMINARY REPORT

Hematological Profile of Sickle Cell Anemia Subjects in Central India: A Cross Sectional Analysis ABSTRACT

INFECTION/ INFLAMMATION

Biological Variations of Hematologic Parameters Determined by UniCel DxH 800 Hematology Analyzer

A Reliable Screening Protocol for Thalassemia and Hemoglobinopathies in Pregnancy An Alternative Approach to Electronic Blood Cell Counting

Hemoglobin. Each alpha subunit has 141 amino acids, and each beta subunit has 146 amino acids.

Evaluation of the Abbott Cell-DYN 3500 Hematology Analyzer in a University Hospital

Continuing Education Questions

Diagnostic difficulties in prevention and control program for thalassemia in Thailand: atypical thalassemia carriers

ORIGINAL EVALUATION. FH9-C 2017 Hematology Auto Differentials, FH9

Performance Evaluation of the Plateletworks in the Measurement of Blood Cell Counts as compared to the Beckman Coulter Unicel DXH 800

20/01/1439. Prof. M. Rushdi. Prof. Mahmoud Rushdi Faculty of Veterinary Medicine Assiut University Egypt.

Red cell disorder. Dr. Ahmed Hasan

Automated Blood Cell Counts. State of the Art. Mauro Buttarello, MD, and Mario Plebani, MD. Abstract

INTERELATIONSHIP BETWEEN IDA AND VITAMIN D DEFICIENCY IS NOW ESTABLISHED

TECHNICAL UNIVERSITY OF MOMBASA

Icd code for cbc with differential/ platelet

Factors affecting oxygen dissociation curve

Optimization of Criteria for Verification of Automated Platelet Counts Generated by the Sysmex XE-2100 Hematology Analyzer

I. Definitions. V. Evaluation A. History B. Physical Exam C. Laboratory evaluation D. Bone marrow examination E. Specialty referrals

Guide to the 1-3 Minute Blood Film Microscopic Review: Why and How?

UTILITY OF ERYTHROCYTE INDICES FOR SCREENING OF β THALASSEMIA TRAIT IN PREGNANT WOMEN ATTENDING ANTENATAL CLINIC

CELL-DYN Strength in Technology, Proven Reliability. Optical WBC Technology. Patented M.A.P.S.S. Differential. Multiple Technologies

Serum soluble transferrin receptor in hypochromic microcytic anaemia

ESM Table 2 Data extraction form and key data from included studies

IRON DEFICIENCY STATUS IN FIRST TIME, REPLACEMENT, VOLUNTARY AND REGULAR MALE BLOOD DONORS AT TERTIARY CARE HOSPITALS OF PESHAWAR, PAKISTAN

Avoiding Early Cancer Claims. Presentation #4. Hank George, FALU

Refrigerated Storage Improves the Stability of the Complete Blood Cell Count and Automated Differential

Haematology Comparability Document

Preferred Clinical Services for Leading Age Florida August 26-27, 2015

Automated Hematology Analyzer. Differentiate with the XT-4000i

Transcription:

50, 48, 2012, 3, ADVIA 2120.,.., ANALYSIS OF DIAGNOSTIC RED CELL CYTOGRAMS, GENERATED BY THE ADVIA 2120 HEMATOLOGY ANALYZER M. Velizarova, T. Yacheva and K. Tzatchev Department of Clinical Laboratory and Clinical Immunology, MUSofia : : : Summary: Key words: Address for correspondence:, -, -., (RBC) -., 946 (342 620 - ) ADVIA 2120 (Siemens Healthcare Diagnostics Inc). (V) (HC),, -,, -. -., Advia 2120,, RBC -,,,... 1, 1431,. 02 92-30-916, e-mail: mvelizarova@abv.bg The laboratory staff is familiar with the basic interpretation of numerical results, obtained by the automated hematology analyzers, but seemingly complex cytograms and histograms are often ignored. The purpose of this study was to identify characteristic red cell (RBC) cytogram patterns in various hematological conditions. Numerical and graphical results of the RBC data in 946 (342 healthy individuals and 620 patients with hematological diseases/conditions) were analyzed by the automated hematology analyzer ADVIA 2120 (Siemens Healthcare Diagnostics Inc). The graphical pattern of red cell distribution according to RBC volume/hemoglobin concentration (V/HC) was evaluated in iron deficiency anemia, heterozygous and homozygous thalassemia, megaloblastic and nonmegaloblastic macrocytosis, dual deficiency anemia, and post-transfusion findings. Red cell cytograms and other automated results were correlated with the clinical profiles and biochemical data. automated hematology analyzers, Advia 2120, cytogram, RBC Milena Velizarova, M. D., Department of Clinical Laboratory and Clinical Immunology, MU, 1, Sv. G. Sofiyski Str., 1431 Sofia, tel. +359 2 92-30-916 e-mail: mvelizarova@abv.bg

.,...... 51 : CBC Complete blood count EDTA Ethylediaminetetra-acetic acid WBC White blood cells RBC Red blood cells Hb Hemoglobin Hct Hematocrit fl femto litre MCV Mean corpuscular volume MCH Mean corpuscular hemoglobin MCHC Mean corpuscular hemoglobin concentration pg pico grams RDW Red cell distribution width NRBC Nucleated red blood cells V/HC Volume/Hemoglobin Concentration (RBC) (- ) -. - (CBC) - -. RBC - -, - - - -. -,. - - CBC [14, 15, 18], RBC - [2, 9, 12]. RBC, -. 12 - [4, 9, 11, 12, 16].,,, -,,, [7, 8, 12]., - (), - RBC [2, 5, 9, 12, 13]. -? -, - - RBC ( WBC - ), -.. - -,,. 962 (342-620 ) ADVIA 2120 (Siemens Healthcare Diagnostics Inc). 2, - 2- ù. - -. -. - (Cooley) Siemens Healthcare Diagnostics.

52, 48, 2012, 3 ( - ) - (2-3º) (5-15º) [1, 12]. - RBC, (V) (HC),.. V/HC RBC (. 1). V/HC, 28 g/dl 41 g/dl. HC 28 g/dl -, 41 g/dl. y, - 60 fl 120 fl. - 60 fl, 120 fl. V/HC. (. 2) 2. : Hb82 g/l, RBC4,93 x 10 12 /l, Hct0.32, MCV65,4 fl, MCH16,6 pg, MCHC254 g/l, CH15,8 pg, RDW18,6%. -. -, -. MCV MCH -, RDW.. 1. V/HC ( N. Kakkar M. Makkar, 2009). - (CH) - 28 g/dl (x) y (41 g/dl). y - (V) - 60 fl () 120 fl (b) V/HC (. 2) 1. : Hb 157 g/l, RBC5,36 x 10 12 /l, Hct0.45, MCV84,0 fl, MCH29,3 pg, MCHC349 g/l, CH28,4 pg, RDW12,2%. - (, ) - V/HC.. 2.. V/HC.... -.. - - (. 2) 3. : Hb117 g/l, RBC6,12 x 10 12 /l, Hct0,39, MCV 63,8 fl, MCH19,1 pg, MCHC300 g/l, CH 19,0 pg, RDW14,5%. - ( - ), -. -, -,. RDW, -,.

.,...... 53 - (. 2) 4. : Hb90 g/l, RBC3,34 x 10 12 /l, Hct0,28, MCV81,9 fl, MCH26,4 pg, MCHC322 g/l, CH26,7 pg, RDW21,9%, NRBC301,6%. -,. -, - - -., RDW -, 20%. (NRBC) - ù. (. 3) 5. : Hb 132 g/l, RBC 3,68 x 10 12 /l, Hct 0,39, MCV 108,4 fl, MCH 35,9 pg, MCHC 331 g/l, CH 35,4 pg, RDW 13,8%. - (MCV 100 fl), - (RDW ). -. -,. (. 3) 6. : Hb 105 g/l, RBC 2.92 x 10 12 /l, Hct 0.32, MCV 110.5 fl, MCH 36.1 pg, MCHC 327 g/l, CH 35.5 pg, RDW 21.2%., -. - - -. RDW -. (. 3) 7. : Hb52 g/l, RBC1,46 x 10 12 /l, Hct0,20, MCV109,0 fl, MCH35,4 pg, MCHC324 g/l, CH34 pg, RDW22.0%. () (RDW 20-25%). -. - -.. 3...... ().. (. 3) 8. : Hb82 g/l, RBC3.90 x 10 12 /l, Hct0.28, MCV71.2 fl, MCH21.0 pg, MCHC295 g/l, CH21.1 pg, RDW22.9%. - -. V/HC, -. -, RDW.,, - ù. [6, 7, 9], - -

54, 48, 2012, 3 [3, 9, 13, 17]., - [5, 8, 12]. - RBC V/HC - - -.. 1 - -. 1. - / - -. (),, RDW, - ( ),, RDW,,, RDW, RBC MCV, RDW, RBC, MCV, RDW, RBC, RDW, RBC, RDW ( > 25%), : 1) - - ; 2) - - ; 3) -. - -. 1.,.,... ADVIA 2120: COULTER LH 750.., 48, 2012, 2, 36-43. 2. A d v i a 120 Hematology System Technology and cytogram interpretation. Bayer Diagnostics, Tarrytown, NY, 2005. 3. A l e x a n d e r, H. D. et al. Cell sizing in chronic lymphoproliferative disorders: an aid to differential diagnosis. J. Clin. Pathol., 45, 1992, 10, 875-879. 4. A s l i n i a, F., J. J. Mazza et S. H. Yale. Megaloblastic anemia and other causes of macrocytosis. Clin. Med. Res., 4, 2006, 3, 236-241. 5. B o u r n e r, G., J. Dhaliwal et J. Sumner. Performance evaluation of the latest fully automated hematology analyzers in a large, commercial laboratory setting: a 4-way, sideby-side study. Lab. Hematol., 11, 2005, 4, 285-297. 6. B u t t a r e l l o, M. Quality specification in haematology: the automated blood cell count. Clin. Chim. Acta, 346, 2004, 1, 45-54. 7. B u t t a r e l l o, M. et M. Plebani. Automated blood cell counts state of the art. Am. J. Clin. Pathol, 130, 2008, 1, 104-116. 8. C o n s t a n t i n o, B. T. The red cell histogram and the dimorphic red cell population. Lab. Med., 42, 2011, 5, 300-308. 9. D e N i c o l a, D. B. Advances in hematology analyzers. Top Companion Anim. Med., 26, 2011, 2, 52-61. 10. J u n g, S. et al. Differential blast counts obtained by automated blood cell analyzers.korean J. Lab. Med., 30, 2010, 6, 540-546. 11. K a f e r l e, J. et C. E. Strzoda. Evaluation of macrocytosis. Am. Fam. Physician, 79, 2009, 3, 203-208. 12. K a k k a r, N. et M. Makkar. Red cell cytograms generated by an ADVIA 120 automated hematology analyzer: characteristic patterns in common hematological conditions. Lab. Med., 40, 2009, 9, 549-555. 13. L e e r s, M. P. et al. Performance evaluation of the Abbott CELL-DYN Ruby and the Sysmex XT-2000i haematology analysers. Int. J. Lab. Hematol., 33, 2011,.1, 19-29. 14. M a c o n i, M. et al. Erythrocyte and reticulocyte indices in iron deficiency in chronic kidney disease: comparison of two methods. Scand. J. Clin. Lab. Invest., 69, 2009, 3, 365-370. 15. N a d a r a j a n, V., P. Sthaneshwar et G. I. Eow. Use of red blood cell indices for the identification of iron deficiency among blood donors. Transfus. Med., 18, 2008, 3, 184-189. 16. S e p p ä, K., P. Sillanaukee et M. Saarni. Blood count and hematologic morphology in nonanemic macrocytosis: differences between alcohol abuse and pernicious anemia.alcohol, 10, 1993, 5, 343. 17. Sullivan, E. Hematology analyzer: From workhorse to thoroughbred. Lab. Med., 37, 2006, 5, 273-278. 18. U r r e c h a g a, E. Clinical utility of the new Beckman-Coulter parameter red blood cell size factor in the study of erithropoiesis. Int. J. Lab. Hematol., 31, 2009, 6, 623-629. 6 2012.