Characterization of OSL response of LiF:Mg,Ti and microlif:mg, Ti to 60 Co gamma source

Similar documents
Response evaluation of CaSO4:Dy; LiF:Mg,Ti and LiF:Mg,Ti microdosimeters using liquid water phantom for clinical photon beams dosimetry

Calibration of two 90 Sr+ 90 Y dermatological applicators

COMPARING THE RESPONSES OF TLD 100, TLD 600, TLD 700 AND TLD 400 IN MIXED NEUTRON-GAMMA FIELDS

Calibration of 90 Sr+ 90 Y sources used for betatherapy, using a postal kit of thermoluminescent dosimeters

Evaluation of glasses containing cadmium for high dose dosimetry by the thermoluminescence technique

FETUS ABSORBED DOSE EVALUATION IN HEAD AND NECK RADIOTHERAPY PROCEDURES OF PREGNANT PATIENTS

Radiologic Units: What You Need to Know

Dependence of the thermoluminescent high-temperature ratio (HTR) of LiF:Mg,Ti detectors on proton energy and dose

Stefan Gutiérrez Lores 1, Gonzalo Walwyn Salas 1, Daniel Molina Pérez 1, Raudel Campa Menéndez 2.

Establishment of the new IEC mammography qualities in a clinical system used for instruments calibration

Implementation of personnel dosimetry systems using thermoluminescence dosimetry

Energy dependent response of Al 2 O 3 and its potential application in personal monitoring.

RADIATION MONITORING DEVICES R A D I A T I O N P R O T E C T I O N & B I O L O G Y - R H O D E S

Two-Dimensional Thermoluminescence Dosimetry System for Proton Beam Quality Assurance

Luminescent materials for dosimetric applications

MODELLING A GAMMA IRRADIATION PROCESS USING THE MONTE CARLO METHOD

CHARACTERIZATION OF TLD-100 DOSIMETER FOR MONITORING THE EXTREMITIES OF WORKERS IN NUCLEAR MEDICINE

MEASUREMENT OF THE EQUIVALENT INDIVIDUAL DOSES FOR PATIENTS IN ANGIOGRAPHY PROCEDURE AND INTERVENTIONAL RADIOLOGY WITH THERMOLUMINESCENT SYSTEMS

EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH A COMBINATION OF TLD ALBEDO AND SULPHUR ACTIVATION TECHNIQUES FOR FAST NEUTRON PERSONNEL DOSIMETRY

"Research Note" CHARACTERIZATION OF A NEW PREPARED Li 2 B 4 O 7 : Mn DOSIMETER FOR γ- IRRADIATION HIGH-DOSE DOSIMETRY *

THERMOLUMINESCENT (TL) DOSIMETRY OF SLOW-NEUTRON FIELDS AT RADIOTHERAPY DOSE LEVEL

THERMOLUMINESCENT DOSIMETRIC SYSTEM USED FOR CARACTERIZATION OF THE UNDERGROUND ENVIRONMENT

Radiation Dosimeters for Foods. Ashish Anand Department of Biological and Agricultural Engineering Texas A&M University

Phantom Positioning Variation in the Gamma Knife Perfexion Dosimetry

The need for standardization of dosimetry in experimental radiation biology

Radiation Monitoring Instruments

TLD as a tool for remote verification of output for radiotherapy beams: 25 years of experience

Mammography calibration qualities establishment in a Mo- Mo clinical system

Study of neutron-dna interaction at the IPEN BNCT Research facility ABSTRACT

Nuclear energy, nuclear technologies, and radiological protection Vocabulary. Part 4: Dosimetry for radiation processing

THERMOLUMINESCENCE RESPONSE OF YTTERBIUM-DOPED AND UNDOPED OF SILICON OPTICAL FIBER SUBJECTED TO PHOTON IRRADIATION

DOSE MEASUREMENTS IN TELETHERAPY USING THERMOLUMINESCENT DOSIMETERS

3/26/2017. Personal Dosimetry Monitoring and Dose Measurements. Agenda. Dosimetric Terms and Definitions Dose Limits External Dosimetry

DEVELOPMENTS IN NEUTRON DOSIMETRY

RPC s Credentialing Programs for Clinical Trials

Radiochromic film dosimetry in water phantoms

Good manufacturing practices (GMP) utilized on human blood irradiation process

Extracranial doses in stereotactic and conventional radiotherapy for pituitary adenomas

IAEA-CN THE ESTRO-EQUAL RESULTS FOR PHOTON AND ELECTRON BEAMS CHECKS IN EUROPEAN RADIOTHERAPY BEAMS*

Dosimetric Characteristics of LiF:Mg,Cu,Na,Si Phosphor

Medical dosimetry using Optically Stimulated Luminescence dots and microstar readers

PHYS 383: Applications of physics in medicine (offered at the University of Waterloo from Jan 2015)

Male Breast Cancer-Dosimetry Evaluation in Teletherapy

RADIATION MONITORING EXPERIMENT USING THERMOLUMINESCENT DOSIMETER FOR THE TR 19 CYCLOTRON AREA IN NUCLEAR RESEARCH INSTITUTE

Sulfur status in long distance runners

RadPro International GmbH i

Infrastructure of the Brazilian Government in Radioprotection Education

In vivo dosimetry with thermoluminescent. dosimeters in external photon beam. radiotherapy

SENSORIAL EVALUATION OF BRAZILLIAN HONEY

Radiation Protection Dosimetry (2008), Vol. 131, No. 4, pp Advance Access publication 29 July 2008

SUMMARY OF PERSONAL DOSIMETRY PRACTICIES IN RCA MEMBER COUNTRIES

Measurement of Dose to Implanted Cardiac Devices in Radiotherapy Patients

MIXED FIELD PERSONNEL DOSIMETRY, PART I: HIGH TEMPERATURE PEAK CHARACTERISTICS OF THE READER-ANNEALED TLD-600*

DOSIMETRIC STUDY OF MONOCRYSTALLINE SILICON SOLAR CELL

DOSE ASSESSMENT WITH PASSIVE PERSONAL DOSIMETERS EXPOSED TO X-RAY GENERATOR USING THE 241 Am CALIBRATION CURVE

Measurements of Air Kerma Index in Computed Tomography: A comparison among methodologies

The Status and Challenges of External Personal Dosimetry

EQUIVALENT DOSE FROM SECONDARY NEUTRONS AND SCATTER PHOTONS IN ADVANCE RADIATION THERAPY TECHNIQUES WITH 15 MV PHOTON BEAMS

Radiation dosimetry in space by means of compact passive luminescent detectors

Chem 481 Lecture Material 3/11/09

SPANISH INTERCOMPARISON OF APPROVED PERSONAL DOSIMETRY SERVICES USING PHOTON RADIATION BEAMS

Entrance surface dose measurements for routine X-ray examinations in Chaharmahal and Bakhtiari hospitals

X-RAYS INDIVIDUAL DOSE ASSESSMENT USING TLD DOSIMETERS

High-Level Dosimetry systems used at CERN

Introduction. Chapter 15 Radiation Protection. Advisory bodies. Regulatory bodies. Main Principles of Radiation Protection

Dosimetric Consideration in Diagnostic Radiology

Large-area Two-Dimensional Thermoluminescence Dosimetry System in Ion Beam Quality Assurance

The use of the TLD-100 for quality assurance in Total Body Irradiation (TBI)

Accreditation of Dosimetry Services

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Dosimetric characterization with 62 MeV protons of a silicon segmented detector for 2D dose verifications in radiotherapy

The clinical use of OSLD

First National Intercomparison of Individual Dosimetry of Photon Radiation in Ukraine

Neutron-Gamma Mixed field Dosimetry on a Child phantom under Therapeutic Proton Irradiation using TL Dosimeters

Process Control Methods in Radiation Technologies

A NEW USER-FRIENDLY EXTREMITY DOSIMETRY SYSTEM DESIGN, COMPARISON, AND TESTING

Radiation Health Protection Manual

Diode calibration for dose determination in total body irradiation

Artigo Original. Daniel Villani 1, Anselmo Mancini 2, Cecilia M. K. Haddad 2, Letícia L. Campos 1

Eighth Annual Chapman Phytosanitary Irradiation Forum. Dosimetry for phytosanitary applications: dos and don ts. Florent KUNTZ

Calibration of Radiation Instruments Used in Radiation Protection and Radiotherapy in Malaysia

Absorbed Dose Response in Water of Kilovoltage X-rays Beams of Radiochromic Film and Thermoluminescent for Brachytherapy Dosimetry

Patient dosimetry for total body irradiation using single-use MOSFET detectors

CALIBRATION OF A TLD ALBEDO INDIVIDUAL NEUTRON MONITOR

Improving personal dosimetry of medical staff wearing radioprotective garments: Design of a new whole-body dosimeter using Monte Carlo simulations

Multilayer Gafchromic film detectors for breast skin dose determination in vivo

Radiation Protection Services in R.Macedonia

Dose Homogeneity of the Total Body Irradiation in vivo and in vitro confirmed with Thermoluminescent Dosimeter

Dosimetry in Life Sciences

Recent Achievements in External Radiation Dosimetry A. Delgado CIEMAT Radiation Dosimetry Unit Avda Complutense 22, Madrid, Spain

Neutron dose evaluation in radiotherapy

Personal Dosimetry. Radiation Protection Section Department of Medical Physics Colchester Hospital University NHS Foundation Trust

Manik Aima, Larry A. DeWerd, Wesley S. Culberson

Dosimetry. Dr. Manfred Sassowsky Cantonal Hospital Lucerne (KSL) Institute for Radio-Oncology

Use of Bubble Detectors to Characterize Neutron Dose Distribution in a Radiotherapy Treatment Room used for IMRT treatments

Development of radiation monitoring services for radiation workers in Saudi Arabia

Assessment of radiation dose to the chest wall and lung of the patients with breast cancer under electron beam therapy

Radiation physics and radiation protection. University of Szeged Department of Nuclear Medicine

Dosimetry Standards and Dissemination Systems for Radiation Processing in China

DETERMINATION OF ESSENTIAL ELEMENTS IN COMMERCIAL BABY FOODS BY INAA

Transcription:

Characterization of OSL response of LiF:Mg,Ti and microlif:mg, Ti to 60 Co gamma source Amanda Bravim, Leticia Lucente Campos Instituto de Pesquisas Energéticas e Nucleares (IPEN / CNEN - SP) Av. Professor Lineu Prestes 2242 05508-000 São Paulo, SP abravin@ipen.br lcrodri@ipen.br Abstract OSL dosimetry has been investigated for medical dosimetry applications due to its characteristics for applications in external beam radiation therapy. The ability to register the absorbed dose accumulated in the detector over extended periods of time, the high sensitivity, small detector size and real time measures of the OSL detectors make this technique suitable to be used as personal dosimetry technique. In the OSL technique no heating is required to the dose measurement, so there are no changes in the physical characteristics of the material and non-destructive readout, in other words, repetitive measures for the same material can be carried out. In this work the gamma dose assessment using LiF:Mg,Ti and microlif:mg,ti dosimeters from Harshaw was evaluated using OSL technique. The dosimeters were previously selected according to its TL sensitivity to 60 Co gamma radiation. The dosimeters were heattreated using a furnace Vulcan model 3-550 PD and were irradiated in air at electronic equilibrium conditions using a 60 Co gamma source with doses ranging from 0.1 up to 12 Gy. The OSL and TL measures were performed using an OSL reader Risø. The studied parameters were reproducibility, dose response and lower detection limit. Key Words: Lithium Fluoride, Optically Stimulated Luminescence, 60 Co gamma source. 1. Introduction The dosimetry of ionizing radiation is essential for the radiological protection programs for quality assurance and licensing of equipment. In radiotherapy treatments is necessary to be sure that the patient is receiving the correct prescribed dose and the main objective of dosimetry in radiotherapy is to determinate with greater precision the absorbed dose to the tumor [1]. The optically stimulated dosimeters (DOSLs) have not been much exploited in medicine yet, but Yukihara and McKeever 920080 mention that research involving optically stimulated luminescence (OSL) technique is increasing gradually in recent years. Properties as high sensitivity and the all-optical nature of the process are the two properties exploited most in medical dosimetry application [2]. The OSL is a signal emitted by an insulating or semiconducting material when exposed to light, after being irradiated. The intensity of the OSL signal is proportional to the dose of radiation absorbed by the detector [3]. The process is similar to the thermoluminescence, but differs in the stimulation: instead of thermal stimulation, in OSL defects in the detector are stimulated by optical means [4].

The OSL response of LiF:Mg,Ti (TLD-100) dosimeters to alpha and beta particles to application to mixed-field radiation dosimetry was investigated by Oster et al by measuring the excitation and emission spectra of OSL and comparing with thermoluminescent (TL) characteristics [5]. This paper aims to measure the OSL and TL response using an OSL reader Risø and study the reproducibility, dose response and lower detection limit of the LiF:Mg,Ti and microlif:mg,ti to OSL technique. 2. Materials and Methods Before irradiation the dosimeters were heat-treated 400ºC/1h using a furnace VULCAN model 3-550 PD plus 100ºC/2h using a furnace FANEN model 315-IEA 11200. Forty dosimeters of each type, LiF:Mg,Ti and microlif:mg,ti, were irradiated in air under electronic equilibrium conditions with a 60 Co gamma source (656.4MBq) to be selected according to their sensitivity. After the TL readings the individual and average TL responses of the dosimeters were obtained, they were separated into 16 groups of 5 detectors each according to their sensitivity (8 groups of microlif:mg,ti and 8 groups of LiF:Mg,Ti). One group was used to be the reference of background measures (0Gy). Table 1 summarizes the heat-treatment of the LiF:Mg,Ti and microlif:mg,ti dosimeters and the parameters used to gamma irradiation, to the selection of dosimeters and doses measures. Table 1 Parameters of gamma irradiation of LiF Dosimeters: heat-treatment, characteristics of dosimeters and gamma sources properties. Material TLD- 100 LiF:Mg,Ti - microlif:mg,ti Heat-Treatment 1h/400ºC + 2h/100ºC Detectors Dimensions LiF:Mg,Ti: 3.15 x 3.15 x 1.00 mm microlif:mg,ti: 1.00 x 1.00 x 1.00 mm Gamma Sources dosimeters selection dose response measures 60 Co gamma source of GMR/IPEN * (656.4MBq) 60 Co Panoramic Irradiator of CTR/IPEN ** (12.46TBq) Dose-rate (40 cm source-detector distance) 19.1 Gy/h (February/2012) (12.46TBq) Transit Dose (40 cm source-detector distance) 0.0517 Gy (February/2012) (12.46TBq) Absorbed Doses 0.1, 0.5, 1.0, 3.0, 5.0, 10, 12 Gy * Gerência de Metrologia das Radiações of IPEN/CNEN-SP ** Centro de Tecnologia das Radiações of IPEN/CNEN-SP To evaluate the doses responses the irradiation parameters for each group of 5 dosimeters were: 40 cm source-detector distance and doses ranging from 0.1 up to 12 Gy, in air

under electronic equilibrium conditions using a 60 Co gamma source (12.46TBq). Each value quoted in this paper is the average of measurements of five dosimeters of the same sensitivity group and the error bars represent the standard deviation of the mean (1σ).The reproducibility and the lower detection limit () were calculated with the respective equations: Reproducib ility % 100 n R R 0 3, where: σ is the standard deviation, n is the number of dosimeters, R is the mean of the response, OSL or TL, of the dosimeters of each group and non-irradiated dosimeters., R 0 is the average response of 3. Results and Discussion The Figure 1 shows the TL dose-response curves of LiF:Mg,Ti and microlif:mg,ti dosimeters to 60 Co gamma radiation. The OSL dose-response curves of the same dosimeters are presented in Figure 2 and 3. The Figure 3 shows the OSL dose-response curve to microlif:mg,ti with all doses values studied. Fig. 1. TL Dose response curves for the LiF:Mg,Ti and microlif:mg,ti dosimeters.

Fig. 2. OSL Dose response curve for the LiF:Mg,Ti dosimeters. Fig. 3. OSL Dose response curve for the microlif:mg,ti TL dosimeters. The TL dose-response curves to 60 Co gamma radiation of both dosimeters present linear behaviour in the dose range from 0.1 to 12 Gy. The OSL dose-response curve to the microlif:mg,ti dosimeters is linear from their, 2Gy, to 12 Gy. The Tables 1 and 2 present the and the reproducibility of the dosimeters studied to 60 Co gamma radiation using the TL and OSL technique, respectively.

Table 1: and reproducibility of the LiF:Mg,Ti and microlif:mg,ti dosimeters to 60 Co using TL technique. TL Dose [Gy] 0 0,1 0,5 1 3 5 10 12 0.1 Gy microlif:mg,ti reproducibility [%] ±1.94 ±1.36 ±0.80 ±1.83 ±1.22 ±1.20 ±1.97 ±2.17 0.1 Gy LiF:Mg,Ti reproducibility [%] ±1.59 ±0.85 ±1.35 ±1.94 ±1.77 ±1.31 ±2.02 ±1.56 Table 2: and reproducibility of the LiF:Mg,Ti and microlif:mg,ti dosimeters to 60 Co using OSL technique. OSL Dose [Gy] 0 0.1 0.5 1 3 5 10 12 2 Gy microlif:mg,ti Reproducibility [%] ±2.08 ±1.97 ±1.59 ±0.75 ±1.16 ±0.85 ±1.38 ±2.40 0.1Gy LiF:Mg,Ti reproducibility [%] ±1.27 ±0.72 ±0.55 ±1.22 ±0.48 ±1.61 ±0.42 ±1.04 Analyzing the Tables 1 and 2, we can conclude that the of microlif:mg,ti for OSL is approximately 10 times higher than the LiF:Mg,Ti and the reproducibility of the two types of dosimeters and to all doses is in accordance with the references in the literature, 5% [2]. To microlif:mg,ti, the reproducibility ranged from ±0.80% to ±2.17% and from ±0.85% to ±2.4% to TL and OSL technique, respectively. To LiF:Mg,Ti, it ranged from ±0.85% to ±2.02% and from ±0.42% to ±1.61% to TL and OSL technique, respectively. 4. Conclusions The OSL dose-response curve is linear to the dose range studied to LiF:Mg,Ti and linear from 3 Gy to 12 Gy to the microlif:mg,ti dosimeters. The microlif:mg,ti dosimeters are more sensitive to the TL than OSL technique and, its is higher than to LiF:Mg,Ti to the OSL technique. As expected, the sensitivity of the microlif:mg,ti is lower than LiF:Mg,Ti considering thar the TL and OSL responses related to the mass of the detector. All values of reproducibility are in accordance with the literature, ±5%, to the two types of dosimeters. Considering the preliminary results, LiF:Mg,Ti dosimeters can be indicate to be used in the OSL measures for application to the gamma dosimetry. Acknowledgments The authors are thankful to MCT: Project INCT for Radiation Metrology in Medicine and CNPq and FAPESP for the financial support.

References [1] METCALFE, P.; KRON, T.; HOBAN, P. The Physics of Radiotherapy X-rays from Linear Accelerators. Madison, WI: Med. Phys, 2007. [2] E.G.Yukihara, S.W.S.McKeever. Optically Stimulated Luminescence - Fundamentals and Applications.1 st Ed. Oklahoma, USA. (2011). [3] BOTTER-JENSEN, L.; McKEEVER, S. W. S.; WINTLE, A. G. Optically stimulated luminescence dosimetry. Amsterdam: Elsevier, 2003. [4] YUKIHARA, E.G.; McKEEVER, S.W.S. Optically stimulated luminescence (OSL) dosimetry in medicine, Phys. Med. Biol., v.53, p.r351-r379, 2008. [5] L.OSTER, Y.S.HOROWITZ, L.PODPALOV. OSL and TL in TLD-100 following alpha and beta irradiation: Application to mixed-field radiation dosimetry, Rad.Measurements. 45, p.1130-1133, 2010.